01CT-5AH BELIMO | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Technical data sheet 01CT-5.. www.belimo.com 01CT-5.. • en-us • 2020-08-06 • Subject to change 1 / 4 Cable Temperature Sensor Used as a duct temperature sensor with a mounting flange or as an immersion temperature sensor in combination with an immersion sleeve. With stainless steel probe and plenum-rated cable. Type Overview Type Output signal Probe length Probe diameter 01CT-5AH Pt100 2" [50 mm] 0.24" [6 mm] 01CT-5BH Pt1000 2" [50 mm] 0.24" [6 mm] 01CT-5EH Ni1000 (JCI) 2" [50 mm] 0.24" [6 mm] 01CT-5LH NTC10k (10k2) 2" [50 mm] 0.24" [6 mm] 01CT-5MH NTC10k3 (Precon) 2" [50 mm] 0.24" [6 mm] 01CT-5QH NTC20k 2" [50 mm] 0.24" [6 mm] Technical Data Electrical Data Electrical connection cable 2 m, 2-wire Cable specification 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40°F to 300°F (-40°C to 150°C), 300 V Functional Data Output signal passive temperature Pt100 Pt1000 Ni1000 (JCI) NTC10k (10k2) NTC10k3 (Precon) NTC20k Application air water Measuring Data Measuring values Temperature Accuracy temperature passive Passive Sensors depending on used type Measuring current Pt100: <1 mA @ 32°F [0°C] Ni1000 (JCI): <5 mA @ 21°C [70°F] NTC10k2: <2 mA @ 77°F [25°C] NTC10k3: <2.7 mA @ 77°F [25°C] NTC20k: <0.5 mA @ 77°F [25°C]

Technical data sheet 01CT-5.. www.belimo.com 01CT-5.. • en-us • 2020-08-06 • Subject to change 2 / 4 Safety Data Ambient humidity max. 95% r.H., non-condensing Protection class IEC/EN III Safety Extra-Low Voltage (SELV) Protection class UL UL Class 2 Supply EU Conformity CE Marking Certification IEC/EN IEC/EN 60730-1 Certification UL cULus acc. to UL60730-1A/-2-9, CAN/CSA E60730-1:02/-2-9 Degree of protection IEC/EN IP67 Degree of protection NEMA/UL NEMA 4X Quality Standard ISO 9001 Safety Notes This device has been designed for use in stationary heating, ventilation and air-conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten humans, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation. The device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed. Remarks Due to self-heating with 2 wire passive sensors, the supply wire current affects the measurement accuracy, so it should not exceed 1 mA. When using lengthy connecting cables (depending on the cross section used), the cable resistance must be taken into account. The lower the impedance of the sensor used, the greater the effect of the line resistance on the measurement, because it generates an offset. General Remarks Concerning Sensors

Technical data sheet 01CT-5.. www.belimo.com 01CT-5.. • en-us • 2020-08-06 • Subject to change 3 / 4 Accessories Optional accessories air Description Type Mounting flange for sensor probe 6 mm, up to max. 120°C [248°F], Plastic A-22D-A03 Mounting flange for sensor probe 6 mm, up to max. 260°C, Brass A-22D-A05 Recommended accessories water Description Type Thermowell pocket (fabricated) Stainless steel, 2" [50 mm], 1/2" NPT, wrench size 3/4" A-22P-A05 Thermowell pocket (fabricated) Brass, 2" [50 mm], 1/2" NPT, wrench size 3/4" A-22P-A17 Thermowell pocket (machined) Stainless steel, 2" [50 mm], 1/2" NPT, wrench size 3/4" A-22P-A36 Thermowell pocket (fabricated) Stainless steel, 4" [100 mm], 1/2" NPT, wrench size 3/4" A-22P-A07 Thermowell pocket (fabricated) Brass, 4" [100 mm], 1/2" NPT, wrench size 3/4" A-22P-A19 Thermowell pocket (machined) Stainless steel, 4" [100 mm], 1/2" NPT, wrench size 3/4" A-22P-A37 Thermowell pocket (fabricated) Stainless steel, 6" [150 mm], 1/2" NPT, wrench size 3/4" A-22P-A09 Thermowell pocket (fabricated) Brass, 6" [150 mm], 1/2" NPT, wrench size 3/4" A-22P-A21 Thermowell pocket (machined) Stainless steel, 6" [150 mm], 1/2" NPT, wrench size 3/4" A-22P-A38 Thermowell pocket (fabricated) Stainless steel, 8" [200 mm], 1/2" NPT, wrench size 3/4" A-22P-A11 Thermowell pocket (fabricated) Brass, 8" [200 mm], 1/2" NPT, wrench size 3/4" A-22P-A23 Thermowell pocket (machined) Stainless steel, 8" [200 mm], 1/2" NPT, wrench size 3/4" A-22P-A39 Thermowell pocket (fabricated) Stainless steel, 12" [300 mm], 1/2" NPT, wrench size 3/4" A-22P-A13 Thermowell pocket (fabricated) Brass, 12" [300 mm], 1/2" NPT, wrench size 3/4" A-22P-A25 Thermowell pocket (fabricated) Stainless steel, 18" [450 mm], 1/2" NPT, wrench size 3/4" A-22P-A15 Thermowell pocket (fabricated) Brass, 18" [450 mm], 1/2" NPT, wrench size 3/4" A-22P-A27 Syringe with thermal paste A-22P-A44 Wiring Diagram

Technical data sheet 01CT-5.. www.belimo.com 01CT-5.. • en-us • 2020-08-06 • Subject to change 4 / 4 Dimensions Humidity seal rolling L1: cable length L2: pocket length Type Probe length Weight 01CT-5AH 2" [50 mm] 0.14 lb [0.065 kg] 01CT-5BH 2" [50 mm] 0.14 lb [0.065 kg] 01CT-5EH 2" [50 mm] 0.14 lb [0.065 kg] 01CT-5LH 2" [50 mm] 0.14 lb [0.065 kg] 01CT-5MH 2" [50 mm] 0.14 lb [0.065 kg] 01CT-5QH 2" [50 mm] 0.14 lb [0.065 kg]