EE600 is a component documented by E+E Elektronik Ges.m.b. The PDF description identifies it as "Differential Pressure Sensor 11-2022." This guide condenses the most useful engineering information from the available PDF so that designers and sourcing teams can identify the checks that still need confirmation in the original document.
Datasheet snapshot
- Manufacturer: E+E Elektronik Ges.m.b....
- Part number: EE600
- Category: Sensor
- Datasheet length: 9 Pages
Specifications and operating details
The following points were extracted from the PDF text. Check the associated conditions, notes and limits in the complete document before using a value in a design.
- measuring range Accuracy @ 20 °C (68 °F), incl.
- hysteresis, non-linearity and repeatability ±0.5 % FS FS = full scale (1 000 Pa or 10 000 Pa) Temperature dependency, typ. <0.03 % from FS/K Response time t 90 Analogue output 1) Digital interface 2) 50 ms / 500 ms / 2 s / 4 s selectable w.
- Long-term stability <0.5 % FS/year Overload limits 1 000 Pa FS 10 000 Pa FS ±10 000 Pa ±80 000 Pa 1) Factory setup analogue output: measurement range 0...100 % FS; response time t 90: 50 ms; displayed unit: Pa; display backlight: on; analo.
- 2) Factory setup RS485: response time t 90: 500 ms; displayed unit: Pa; display backlight: on Measurands v1.9 / Modification rights reserved | 6 Technical Data Outputs Analogue Analogue output 1) 0 - 5 V or 0 - 10 V -1 mA < IL < 1 mA IL =.
- Factory setup analogue outputs: measurement range 0...100 % FS; response time t 90: 50 ms; displayed unit: Pa; display backlight: on; analogue outputs: 0 - 10 V and 4 - 20 mA.
- voltage 30 V DC 15 - 35 V DC or 24 V AC ±20 % Current consumption, typ. @ 0 Pa (0 psi) / 24 V DC Analogue output Digital interface Without display 23 mA 8 mA Display with backlight 49 mA 29 mA Electrical connection Analogue output Digital.
- 2.5 mm 2 (AWG14) Cable gland M16x1.5 Display Graphic, with backlight Selectable units on display with Analogue output via DIP switch Analogue output and digital interface via PCS10 Pa, kPa, mbar, mm H 2O Pa, kPa, mbar, mm H 2O, inch WC, m.
Topics covered by the datasheet
The document includes sections related to:
- Features
Engineering review checklist
- Confirm the exact ordering code, package, pinout or terminal arrangement and document revision.
- Compare recommended operating conditions with absolute maximum ratings and retain adequate design margin.
- Validate electrical, thermal, mechanical and environmental behavior in the final application.
Always confirm values against the latest manufacturer-controlled datasheet, especially when qualifying a substitute or releasing a production BOM.