Serie MN Pinces ampèremetriques pour courant AC Non-contractual document 906131102C - Ed 1 3.00 (1/2) YN serie Current clamps for AC current YN SERIES The Y series clamps are designed to be both rugged and versatile whilst remaining easy to use. The jaws are designed so that the clamps can be hooked onto cables or clamped onto busbars for current measurement up to 600 A AC. There are two types of Y series clamps available: The fi rst acts as a current transformer (ratios of 100:1 or 1000:1), giving an output current that may be read by a multimeter, logger or other suitable devices with appropriate current calibres. The other kind of Y series clamp has a DC voltage output proportional to the AC current measured, allowing instruments without current calibres to measure, display and record currents on a DC voltage calibre. There is also a model available specifi cally for direct use with oscilloscopes.
Serie MN Pinces ampèremetriques pour courant AC Non-contractual document 906131102C - Ed 1 3.00 (2/2) YN serie Current clamps for AC current 66 mm 195 mm Cable: 30 mm Ø max Busbar: 63 x 5 mm max 2 cables: 25 mm Ø max I 34 mm
Serie MN Pinces ampèremetriques pour courant AC Non-contractual document 906131102C - Ed 1 3.01 (1/1) YN serie Current clamp for AC current Model Y1N ELECTRICAL SPECIFICATIONS
- Current range: 4 A AC .. 600 A/uni00A0AC
- Current transformation ratio: 1000:1
- Output signal: 1 mA/uni00A0AC / A AC
- Accuracy (1): Primary current 4 A 25 A 100 A 250 A 500 A 600 A (2) Accuracy in % of output signal 4.5 % + 0.5 mA 4.5 % 3.5 % 3 % 3 % 3 % Phase shift not specified 4° 2° 2° 2° 2° class 3 at 1.25 VA (1) Conditions of reference: 23 °C ± 5 °K, 20 % to 75 % RH, 48/uni00A0Hz to 65/uni00A0Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no current-carrying conductor nearby, centred test sample, load impedance 5 Ω. (2) 700 A for 10 minutes max.
- Bandwidth: 48 Hz .. 1,000 Hz
- Load impedance: 5 /uni03A9 max
- Overload:
700 A for 10 minutes
- Maximum output voltage (secondary open): Electronic protection circuit limiting voltage to 10/uni00A0V peak max
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage: 600/uni00A0VRMS
- Infl uence of adjacent and parallel conductors: </uni00A030 mA / A at 50 Hz
- Infl uence of conductor position in jaws: ±1.5 % MECHANICAL SPECIFICATIONS
- Operating temperature: -15 °C .. +50 °C
- Storage temperature: -40 °C .. +85 °C
- Infl uence of temperature: </uni00A00.1 % per 10 °K
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 33/uni00A0mm
- Clamping capacity: Cable: Ø/uni00A0max 30/uni00A0mm Busbar: 63 x 5/uni00A0mm
- Casing protection rating: IP20 in accordance with IEC 529
- Drop test: 1.5 m (IEC/uni00A068-2-32)
- Shock resistance: 100 g, in accordance with IEC/uni00A068-2-27
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0 mm test in accordance with IEC/uni00A068-2-6
- Self-extinguishing capability: UL94 V0
- Dimensions: 66 x 195 x 34/uni00A0mm
- Weight: 420 g
- Colour: Dark grey
- Output: 1.5 m two-wire lead with double or reinforced insulation terminated by 2/uni00A0 elbowed male safety plugs (4 mm) SAFETY SPECIFICATIONS
- Electrical safety: Double or reinforced insulation between the primary and secondary circuits and the outer casing in accordance with IEC/uni00A01010-2-032. - 600/uni00A0V category III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class/uni00A0B EN/uni00A050082-2: - Electrical discharge: IEC/uni00A01000-4-2 - Radiated field: IEC 1000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50/60 Hz: IEC/uni00A01000-4-8 Current 500 A AC Ratio 1000 / 1 Output 1 mA / A To order Reference AC current clamp model Y1N with operating manual P01120001A
Serie MN Pinces ampèremetriques pour courant AC Non-contractual document 906131102C - Ed 1 3.02 (1/1) YN serie Current clamp for AC current Current clamp for AC current ELECTRICAL SPECIFICATIONS
- Current range: 4 A AC .. 600 A AC
- Current transformation ratio: 1000:1
- Output signal: 1 mA/uni00A0AC / A AC
- Accuracy (1): Primary current 4 A 25 A 100 A 250 A 500 A 600 A (2) Accuracy in % of output signal 3 % + 0.5 mA 3 % 1.5 % 1 % 1 % 1 % Phase shift not specified 3° 1.5° 1° 1° 1° class 1 at 1.25 VA (1) Conditions of reference: 23 °C ± 5 °K, 20 % to 75 % RH, 48/uni00A0Hz to 65/uni00A0Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no current-carrying conductor nearby, centred test sample, load impedance 5 Ω. (2) 700 A for 10 minutes max
- Bandwidth: 48 Hz .. 1,000 Hz
- Load impedance: 5 /uni03A9 max
- Overload:
- Maximum output voltage (secondary open): Electronic protection circuit limiting voltage to 10/uni00A0V/uni00A0peak max
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage: 600/uni00A0VRMS
- Infl uence of adjacent and parallel conductors: </uni00A030 mA / A at 50 Hz
- Infl uence of conductor position in jaws: </uni00A01 % MECHANICAL SPECIFICATIONS
- Operating temperature: -15 °C .. +50 °C
- Storage temperature: -40 °C .. +85 °C
- Infl uence of temperature: </uni00A00.1 % per 10 °K
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 33/uni00A0mm
- Clamping capacity: Cable: Ø/uni00A0max 30/uni00A0mm Busbar: 63 x 5/uni00A0mm
- Casing protection rating: IP20 in accordance with IEC 529
- Drop test: 1.5 m (IEC/uni00A068-2-32)
- Shock resistance: 100 g, in accordance with IEC/uni00A068-2-27
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm test in accordance with IEC/uni00A068-2-6
- Self-extinguishing capability: UL94 V0
- Dimensions: 66 x 195 x 34/uni00A0mm
- Weight: 420 g
- Colour: Dark grey
- Output: 1.5 m two-wire lead with double or reinforced insulation terminated by 2/uni00A0 elbowed male safety plugs (4 mm) SAFETY SPECIFICATIONS
- Electrical safety: Double or reinforced insulation between the primary and secondary circuits and the outer casing in accordance with IEC/uni00A01010-2-032. - 600/uni00A0V category III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class/uni00A0B EN/uni00A050082-2: - Electrical discharge: IEC/uni00A01000-4-2 - Radiated field: IEC 1000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50/60 Hz: IEC/uni00A01000-4-8 Current 500 A AC Ratio 1000 / 1 Output 1 mA / A To order Reference AC current clamp model Y2N with operating manual P01120028A Model Y2N
Serie MN Pinces ampèremetriques pour courant AC Non-contractual document 906131102C - Ed 1 3.03 (1/1) YN serie Current clamp for AC current Current clamp for AC current ELECTRICAL SPECIFICATIONS
- Current range: 4 A AC .. 600 A AC
- Current transformation ratio: 100:1
- Output signal: 10 mA/uni00A0AC / A AC
- Accuracy (1): Primary current 4 A 25 A 100 A 250 A 500 A 600 A (2) Accuracy in % of output signal 5 % + 5 mA 5 % 3 % 3 % 3 % 3 % Phase shift not specified 6° 5 ° 3° 3° 3° class 3 at 2.5 VA (1) Conditions of reference: 23 °C ± 5 °K, 20 % to 75 % RH, 48/uni00A0Hz to 65/uni00A0Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no current-carrying conductor nearby, centred test sample, load impedance 0.1 Ω. (2) 700 A for 10 minutes max.
- Bandwidth: 48 Hz .. 1,000 Hz
- Load impedance: 0.1 /uni03A9 max
- Overload:
- Maximum output voltage (secondary open): Electronic protection circuit limiting voltage to 10/uni00A0V peak max
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage: 30/uni00A0VRMS
- Infl uence of adjacent and parallel conductors: </uni00A030 mA / A at 50 Hz
- Infl uence of conductor position in jaws: ±1 % MECHANICAL SPECIFICATIONS
- Operating temperature: 15 °C .. +50 °C
- Storage temperature: -40 °C .. +85 °C
- Infl uence of temperature: </uni00A00.1 % per 10 °K
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 33/uni00A0mm
- Clamping capacity: Cable: Ø/uni00A0max 30/uni00A0mm Busbar: 63 x 5/uni00A0mm
- Casing protection rating: IP20 in accordance with IEC 529
- Drop test: 1.5 m (IEC/uni00A068-2-32)
- Shock resistance: 100 g, in accordance with IEC/uni00A068-2-27
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm test in accordance with IEC/uni00A068-2-6
- Self-extinguishing capability: UL94 V0
- Dimensions: 66 x 195 x 34/uni00A0mm
- Weight: 420 g
- Colour: Dark grey
- Output: 1.5 m two-wire lead with double or reinforced insulation terminated by 2/uni00A0 elbowed male safety plugs (4 mm) SAFETY SPECIFICATIONS
- Electrical safety: Double or reinforced insulation between the primary and secondary circuits and the outer casing in accordance with IEC/uni00A01010-2-032. - 600/uni00A0V category III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class/uni00A0B EN/uni00A050082-2: - Electrical discharge: IEC/uni00A01000-4-2 - Radiated field: IEC 1000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50/60 Hz: IEC/uni00A01000-4-8 Current 500 A AC Ratio 100 / 1 Output 10 mA / A To order Reference AC current clamp model Y3N with operating manual P01120029A Model Y3N
Serie MN Pinces ampèremetriques pour courant AC Non-contractual document 906131102C - Ed 1 3.04 (1/1) YN serie Current clamp for AC current Current clamp for AC current ELECTRICAL SPECIFICATIONS
- Current range: 4 A AC .. 600 A AC
- Output signal: 1 mV DC / A AC
- Accuracy (1): Primary current 2 A 25 A 100 A 250 A 500 A 600 A (2) Accuracy in % of output signal 5 % + 0.5 mV DC 5 % 2 % 1 % 1 % 2 % (1) Conditions of reference: 23 °C ± 5 °K, 20 % to 75 % RH, 48/uni00A0Hz to 65/uni00A0Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no current-carrying conductor nearby, centred test sample, load impedance 10 MΩ. (2) 600 A for 10 minutes max
- Bandwidth: 48 Hz .. 1,000 Hz (error: add 2 % to reference)
- Load impedance: > 100 k/uni03A9 max
- Overload:
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage: 600/uni00A0VRMS
- Infl uence of adjacent and parallel conductors: </uni00A030 mA / A at 50 Hz
- Infl uence of conductor position in jaws: ±1 % MECHANICAL SPECIFICATIONS
- Operating temperature: 15 °C .. +50 °C
- Storage temperature: -40 °C .. +85 °C
- Infl uence of temperature: </uni00A00.1 % per 10 °K
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 33/uni00A0mm
- Clamping capacity: Cable: Ø/uni00A0max 30/uni00A0mm Busbar: 63 x 5/uni00A0mm
- Casing protection rating: IP20 in accordance with IEC 529
- Drop test: 1.5 m (IEC/uni00A068-2-32)
- Shock resistance: 100 g, in accordance with IEC/uni00A068-2-27
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm test in accordance with IEC/uni00A068-2-6
- Self-extinguishing capability: UL94 V0
- Dimensions: 66 x 195 x 34/uni00A0mm
- Weight: 420 g
- Colour: Dark grey
- Output: 1.5 m two-wire lead with double or reinforced insulation terminated by 2/uni00A0 elbowed male safety plugs (4 mm) SAFETY SPECIFICATIONS
- Electrical safety: Double or reinforced insulation between the primary and secondary circuits and the outer casing in accordance with IEC/uni00A01010-2-032. - 600/uni00A0V category III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class/uni00A0B EN/uni00A050082-2: - Electrical discharge: IEC/uni00A01000-4-2 - Radiated field: IEC 1000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50/60 Hz: IEC/uni00A01000-4-8 Current 500 A AC Output 1 mV/uni00A0DC / A AC To order Reference AC current clamp model Y4N with operating manual P01120005A Model Y4N
Serie MN Pinces ampèremetriques pour courant AC Non-contractual document 906131102C - Ed 1 3.05 (1/3) YN serie
DESCRIPTION
This 500 A AC clamp can be used for the display and measurement of ‘current’ curves. It comes with a coaxial cable terminated by a BNC plug, thus making it the ideal tool for use with oscilloscopes. It supplies a mV output signal that is directly proportional to the measured current. ELECTRICAL SPECIFICATIONS
- Current range: 1 A AC .. 500 A AC (1,200 A peak)
- Output signal: 1 mV AC / A AC (0.5 V for 500 A)
- Accuracy and phase shift (1): % Accuracy of output signal ≤/uni00A05 % + 0.3 mV ≤/uni00A05 % ≤/uni00A02 % Phase shift not specified ≤/uni00A03° ≤/uni00A01°
- Bandwidth: 5/uni00A0Hz .. 10 kHz (at -3 dB) (depending on current)
- Rise/fall time from 10 % to 90 %: 37 µs
- 10 % delay time: 1 µs
- Ampere second product: 10 A.s
- Insertion impedance (at 400 Hz / 10/uni00A0kHz): < 0.1 m/uni03A9 / < 3.1 m/uni03A9
- dV / dt: 0.24 mV / µs (typical)
- Maximum currents:
500 A constant
700 A: 10 minutes operation / 30 minutes shutdown
for frequency ≤ 2 kHz (limitation proportional to the inverse of one third of the frequency above that)
- Internal load impedance: ≤ 100 /uni03A9 / 4.7 nF
- Infl uence of temperature: ≤/uni00A00.15 % of output signal per 10 °K
- Infl uence of adjacent conductor: ≤/uni00A05 µV / A at 50 Hz
- Infl uence of conductor position in jaws: ≤ 1.5 % + 0.1 A AC MECHANICAL SPECIFICATIONS
- Operating temperature: -25 °C to +50 °C
- Storage temperature: -40 °C to +80 °C
- Relative humidity for operation: 0 to 85/uni00A0% RH decreasing linearly above 35 °C
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 33/uni00A0mm
- Clamping capacity: Cable: Ø max 30/uni00A0mm Busbar: 1 busbar of 63 x 5/uni00A0mm
- Casing protection rating: IP20 (IEC/uni00A0529)
- Drop test: 1.5 m (IEC/uni00A068-2-32)
- Shock resistance: 100 g / 6 ms / half-periode (IEC/uni00A068-2-27)
- Protection against impacts: IK04 0.5 J (EN 50102)
- Vibration resistance: 10 / 55/10 Hz 0.15/uni00A0mm (IEC/uni00A068-2-6)
- Self-extinguishing capability: UL94 V0
- Dimensions: 195 x 66 x 34/uni00A0mm
- Weight: 420 g
- Colour: Dark grey
- Output: Via 2 m coaxial cable terminated by insulated BNC plug SAFETY SPECIFICATIONS
- Electrical safety: Instrument with double insulation or reinforced insulation between the primary the secondary and the grippable part located under the guard as per IEC/uni00A01010-1 & IEC/uni00A01010-2-032 - 600/uni00A0V category III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class/uni00A0B EN/uni00A050082-2: - Electrostatic discharge: IEC/uni00A01000-4-2 4 kV level 2 performance criterion B 8 kV in the air level 3 performance criterion/uni00A0B - Radiated field: IEC/uni00A01000-4-3
10 V/m performance criterion/uni00A0A
- Fast transients: IEC/uni00A01000-4-4 1 kV level 2 performance criterion B 2 kV level 3 performance criterion B - Magnetic field at 50/60 Hz: IEC/uni00A01000-4-8 field of 400 A/m at 50 Hz: < 1 A Current 1,200 A peak Output 1 mV / A Oscilloscope clamp for AC current Model Y7N (insulated AC current probe)
Serie MN Pinces ampèremetriques pour courant AC Non-contractual document 906131102C - Ed 1 3.05 (2/3) YN serie CURVES Error on measurement at 50 Hz Phase shift at 50 Hz Frequency response Phase shift according to frequency Influence of frequency and derating Influence of DC current Oscilloscope clamp for AC current Model Y7N (insulated AC current probe) Frequency Hz 5 Hz to 10 Hz 10 Hz to 20 Hz 20 Hz to 45 Hz 65 Hz to 3 kHz 3 kHz to 6 kHz 6 kHz to 10 kHz
1 A to 200 A 15 %
200 A not spec.
1 A to 300 A 5 %
300 A to 400 A 15 %
400 A to 500 A 25 %
1 A to 500 A 5 %
1 A to 50 A 5 % + 0.4 A
50 A to 500 A 5 %
500 A not spec. 1 A to 100 A 15 % + 0.4 A > 100 A not spec.
1 A to 50 A -3 dB
50 A not spec. - Error in % of reading; not spec. means not specifi ed - Do not exceed 500 A for measurement with constant operation, and for the derating, use the formula 500 (A) * 2 / F (kHz) to calculate the maximum current in A AC, in constant use, depending on the frequency in kHz. DC current In Amps Frequency in Hz Current A AC error in % YN CLAMP error phase in ° phase Current A AC Current In Amps Frequency
Serie MN Pinces ampèremetriques pour courant AC Non-contractual document 906131102C - Ed 1 3.05 (3/3) YN serie RESPONSE TO A SQUARE SIGNAL
5 A at 10 Hz 5 A at 50 Hz
5 A at 500 Hz 5 A at 4 kHz
(1) Conditions of reference: 23 °C ± 3 °K, 20 % to 75 % RH, sinusoidal signal with frequency of 48 Hz at 1 kHz, external magnetic fi eld < 40 A/m, no DC components, no external conductor with circulating current, conductor centred for measurement, load impedance > 1 MΩ / < 100 pF. To order Reference AC current clamp model Y7N for oscilloscope with operating manual P01120075 Oscilloscope clamp for AC current Model Y7N (insulated AC current probe)