XC2220U INFINEON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 105

Technical content

V1.2 2012-07 Microcontrollers 16/32-Bit Architecture XC2220U 16/32-Bit Single-Chip Microcontroller with 32-Bit Performance XC2000 Family / Compact Line

81726 Munich, Germany

© 2012 Infineon Technologies AG All Rights Reserved. Legal Disclaimer The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation, warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices, please contact the nearest Infineon Technologies Office (www.infineon.com). Warnings Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered.

V1.2 2012-07 Microcontrollers 16/32-Bit Architecture XC2220U 16/32-Bit Single-Chip Microcontroller with 32-Bit Performance XC2000 Family / Compact Line

XC2000 Family / Compact Line Data Sheet V1.2, 2012-07 Trademarks C166™, TriCore™ and DAVE™ are tra demarks of Infineon Technologies AG. XC2220U Data Sheet Revision History: V1.2 2012-07 Previous Versions: V1.0 2010-12, V1.1 2011-09 Page Subjects (major changes since last revision) 50, 51 The value of absolute sum of overload currents parameter in absolute maximum rating parameter and operating conditions tables are switched. 72 Table description on coding of bit field LEVxV is updated. We Listen to Your Comments Is there any information in this document that you feel is wrong, unclear or missing? Your feedback will help us to continuously improve the quality of this document. Please send your proposal (including a reference to this document) to: mcdocu.comments@infineon.com

XC2000 Family / Compact Line Table of Contents Data Sheet 1 V1.2, 2012-07 Table of Contents

XC2000 Family / Compact Line Table of Contents Data Sheet 2 V1.2, 2012-07

XC2000 Family / Compact Line Summary of Features Data Sheet 3 V1.2, 2012-07 16/32-Bit Single-Chip Microcontroller with 32-Bit Performance XC2220U (XC2000 Family)

1 Summary of Features

For a quick overview and easy reference, the features of the XC2220U are summarized here.

  • High-performance CPU with five-stage pipeline and MPU – 15.2 ns instruction cycle @ 66 MHz CPU clock (single-cycle execution) – One-cycle 32-bit addition and subtraction with 40-bit result – One-cycle multiplication (16 × 16 bit) – Background division (3 2 / 16 bit) in 21 cycles – One-cycle multiply -and-accumulate (MAC) instructions – Enhanced Boolean bit manipulation facilities – Zero-cycle jump execution – Additional instructions to support HLL and operating systems – Register-based design with mult iple variable register banks – Fast context switching support with two additional local register banks – 16 Mbytes total linear address space for code and data – 1,024 Bytes on-chip special function re gister area (C166 Family compatible) – Integrated Memory Protection Unit (MPU)
  • Interrupt system with 16 priority levels providing 46 interrupt nodes – Selectable external inputs for interrupt generation and wake-up – Fastest sample-rate 15.2 ns
  • Eight-channel in terrupt-driven single-cycle data transfer with Peripheral Event Controller (PEC), 24-bit pointers cover total address space
  • Clock generation from internal or external clock sources, using on-chip PLL or prescaler
  • Hardware CRC-Checker with Programmabl e Polynomial to Supervise On-Chip Memory Areas
  • On-chip memory modules – 2 Kbytes on-chip dual-port RAM (DPRAM) – 2 Kbytes on-chip data SRAM (DSRAM) – 4 Kbytes on-chip program/data SRAM (PSRAM) – Up to 64 Kbytes on-chip program memory (Flash memory) – Memory content protection through Error Correction Code (ECC) for Flash memory and through parity for RAMs

XC2000 Family / Compact Line Summary of Features Data Sheet 4 V1.2, 2012-07

  • On-Chip Peripheral Modules – Synchronizable 12-bit A/D Converter with up to 10 channels, conversion time below 1 μs, optional data preprocessing (data reduction, range check), broken wire detection – 16-channel general purpose capture/compare unit (CC2) – Capture/compare unit for flexible PWM signal generation (CCU60) – Multi-functional general purpose timer unit with 5 timers – Up to 2 serial interface channels to be used as UART, LIN, high-speed synchronous channel (SPI/QSPI), IIC bus interface (10-bit addressing, 400 kbit/s), IIS interface – On-chip system timer and on-chip real time clock
  • Single power supply from 3.0 V to 5.5 V
  • Power reduction and wake-up mode s with flexible power management
  • Programmable window watchdog timer and oscillator watchdog
  • Up to 33 general purpose I/O lines
  • On-chip bootstrap loaders
  • Supported by a full range of development tools including C compilers, macro- assembler packages, emulators, evalua tion boards, HLL debuggers, simulators, logic analyzer disassemblers, programming boards
  • On-chip debug support via Device Access Port (DAP), Single-Pin DAP (SPD) or JTAG interface
  • 48-pin Green VQFN package , 0.5 mm (10.7 mil) pitch

Ordering Information

The ordering code for an Infineon microcontroller provides an exact reference to a specific product. This ordering code identifies:

  • the function set of the corresponding product type
  • the temperature range 1): – SAF-…: -40°C to 85°C – SAH-…: -40°C to 110°C – SAK-…: -40°C to 125°C
  • the package and the type of delivery. For ordering codes for the XC2220U please c ontact your sales representative or local distributor. This document describes several derivatives of the XC2220U group: Basic Device Types are readily available and Special Device Types are only available on request. 1) Not all derivatives are offered in all temperature ranges.

XC2000 Family / Compact Line Summary of Features Data Sheet 5 V1.2, 2012-07 As this document refers to all of these derivatives, some descriptions may not apply to a specific product, in particular to the special device types. For simplicity the term XC2220U is used for all derivatives throughout this document.

XC2000 Family / Compact Line Summary of Features Data Sheet 6 V1.2, 2012-07

1.1 Basic Device Types

Basic device types are available and can be ordered through Infineon’s direct and/or distribution channels. Table 1 Synopsis of XC2220U Basic Device Types Derivative1) 1) x is a placeholder for available s peed grade in MHz. Can be 40 or 66. Flash Memory2) 2) Specific information about the on-chip Flash memory in Table 3. PSRAM DSRAM3) 3) All derivatives additionally provide 2 Kbytes DPRAM. Capt./Comp. Modules ADC Chan. 4) Specific information about the available channels in Table 5. Interfaces4) XC2220U-8FxV 64 Kbytes 4 Kbytes

2 Kbytes

10 2 Serial Chan.

XC2000 Family / Compact Line Summary of Features Data Sheet 7 V1.2, 2012-07

1.2 Special Device Types

Special device types are only available for high-volume applications on request. Table 2 Synopsis of XC2220U Special Device Types Derivative1) 1) x is a placeholder for available s peed grade in MHz. Can be 40 or 66. Flash Memory2) 2) Specific information about the on-chip Flash memory in Table 3. PSRAM DSRAM3) 3) All derivatives additionally provide 2 Kbytes DPRAM. Capt./Comp. Modules ADC4) Chan. 4) Specific information about the available channels in Table 5. Interfaces4) XC2220U-4FxV 32 Kbytes 4 Kbytes 10 2 Serial Chan.

XC2000 Family / Compact Line Summary of Features Data Sheet 8 V1.2, 2012-07

1.3 Definition of Feature Variants

The XC2220U types are offered with several Flash memory sizes. Table 3 and Table 4 describe the location of the available Flash memory. The XC2220U types are offered wi th different interface options. Table 5 lists the available channels for each option. Table 3 Continuous Flash Memory Ranges Total Flash Size 1st Range 1) 1) The uppermost 4-Kbyte sector of the first Flash segment is reserved for internal use (C0’F000H to C0’FFFFH). 2nd Range 3rd Range

64 Kbytes C0’0000 H …

C0’EFFFH C1’0000H … C1’0FFFH n.a.

32 Kbytes C0’0000 H …

C0’7FFFH n.a. n.a. Table 4 Flash Memory Module Allocation (in Kbytes) Total Flash Size Flash 0 1) 1) The uppermost 4-Kbyte sector of the first Flas h segment is reserved for internal use (C0’F000H to C0’FFFFH). Flash 1 64 64 n.a. 32 32 n.a. Table 5 Interface Channel Association Total Number Available Channels / Message Objects

10 ADC0 channels CH0, CH2, CH3, CH4, CH8, CH9, CH16, CH17, CH19,

2 serial channels U0C0, U0C1

XC2000 Family / Compact Line General Device Information Data Sheet 9 V1.2, 2012-07

2 General Device Information

The XC2220U series (16/32-Bit Single-Chip Microcontroller with 32-Bit Performance) is a part of the In fineon XC2000 Family of full-feature single- chip CMOS microcontrollers. These devices extend the functionality and performance of the C166 Family in terms of instructions (MAC unit), peripherals, and speed. They combine high CPU performance (up to 66 million instructions per second) with extended peripheral functionality and enhanced IO c apabilities. Optimized peripherals can be adapted flexibly to meet the application r equirements. These derivatives utilize clock generation via PLL and internal or external clock sources. On-chip memory modules include program Flash, program RAM, and data RAM. Figure 1 XC2220U Logic Symbol MC_XY_LOGSYMB48 Port 2 12 bit Port 6 3 bit VAGND (1) VAREF (1) VDDPB (3) VSS (3) VDDIM (2) XTAL1 XTAL2 Port 10 12 bit Port 5 6 bit via Port Pins SPD/DAP/ JTAG 1 / 2 / 4 bit TRST Debug 2 bitTESTM PORST

XC2000 Family / Compact Line General Device Information Data Sheet 10 V1.2, 2012-07

2.1 Pin Configuration and Definition

The pins of the XC2220U are described in detail in Table 6, which includes all alternate functions. For further explanations please refer to the footnotes at the end of the table. The following figure summarizes all pins, showing their locations on the four sides of the package. Figure 2 XC2220U Pin Configuration (top view) MC _XY_PIN48 1 36 VQFN48 P5.3 P5.2 VDDPB TESTM P6.3 P6.1 VAGND VAREF P6.0 P5.0 P2. 6 P2. 7 P2. 8 P10.4 P10.0 P10.3 P10.2 P10.1 P10.5 P10.6 P10.7 P10.12 PORST VDDIM XTAL2 P10.9 P10.8 VDDPB P2.2 P2.1 P2.0 VDDPB P2.3 P5.8 P5.9 VDDIM P2.5 P2.4 XTAL1 TRST P5.4 P2.9 P2.10 P2.13 P10.10 VSS VSS VSS

XC2000 Family / Compact Line General Device Information Data Sheet 11 V1.2, 2012-07 Key to Pin Definitions

  • Ctrl.: The output signal for a port pin is selected by bit field PC in the associated register Px_IOCRy. Output O0 is selected by setting the respective bit field PC to 1x00B, output O1 is selected by 1x01B, etc. Output signal OH is controlled by hardware.
  • Type: Indicates the pad type and its power supply domain (B, M). – St: Standard pad – Sp: Special pad e.g. XTALx – DA: Digital IO and analog input – In: Input only pad – PS: Power supply pad Table 6 Pin Definitions and Functions Pin Symbol Ctrl. Type Function

1 TESTM

Enables factory test modes, must be held HIGH for normal operation (connect to VDDPB). An internal pullup device will hold this pin high when nothing is driving it. 2T R S T II n / B Test-System Reset Input For normal system operation, pin TRST should be held low. A high level at this pin at the rising edge of PORST activates the XC2220U’s debug system. In this case, pin TRST must be driven low once to reset the debug system. An internal pulldown device will hold this pin low when nothing is driving it. 3 P6.3 O0 / I St/B Bit 3 of Port 6, General Purpose Input/Output T3OUT O2 St/B GPT12E Timer T3 Toggle Latch Output ADC0_REQT RyF IS t / B External Request Trigger Input for ADC0/1 4 P6.1 O0 / I DA/B Bit 1 of Port 6, General Purpose Input/Output ADC0_CH17 I DA/B Analog Input Channel 17 for ADC0 EMUX1 O1 DA/B External Analog MUX Control Output 1 (ADC0) T3OUT O2 DA/B GPT12E Timer T3 Toggle Latch Output ADC0_REQT RyE ID A / B External Request Trigger Input for ADC0 ESR1_6 I DA/B ESR1 Trigger Input 6

XC2000 Family / Compact Line General Device Information Data Sheet 12 V1.2, 2012-07 5 P6.0 O0 / I DA/B Bit 0 of Port 6, General Purpose Input/Output ADC0_CH16 I DA/B Analog Input Channel 16 for ADC0 EMUX0 O1 DA/B External Analog MUX Control Output 0 (ADC0) BRKOUT O3 DA/B OCDS Break Signal Output ADC0_REQG TyG ID A / B External Request Gate Input for ADC0 10 P5.0 I In/B Bit 0 of Port 5, General Purpose Input ADC0_CH0 I In/B Analog Input Channel 0 for ADC0 11 P5.2 I In/B Bit 2 of Port 5, General Purpose Input ADC0_CH2 I In/B Analog Input Channel 2 for ADC0 TDI_A I In/B JTAG Test Data Input 12 P5.3 I In/B Bit 3 of Port 5, General Purpose Input ADC0_CH3 I In/B Analog Input Channel 3 for ADC0 T3INA I In/B GPT12E Timer T3 Count/Gate Input 13 P5.4 I In/B Bit 4 of Port 5, General Purpose Input ADC0_CH4 I In/B Analog Input Channel 4 for ADC0 T3EUDA I In/B GPT12E Timer T3 External Up/Down Control Input TMS_A I In/B JTAG Test Mode Selection Input 14 P5.8 I In/B Bit 8 of Port 5, General Purpose Input ADC0_CH8 I In/B Analog Input Channel 8 for ADC0 CCU60_T12 HRC II n / B External Run Control Input for T12 of CCU60 CCU60_T13 HRC II n / B External Run Control Input for T13 of CCU60 15 P5.9 I In/B Bit 9 of Port 5, General Purpose Input ADC0_CH9 I In/B Analog Input Channel 9 for ADC0 CC2_T7IN I In/B CAPCOM2 Timer T7 Count Input 16 P2.0 O0 / I DA/B Bit 0 of Port 2, General Purpose Input/Output ADC0_CH19 I DA/B Analog Input Channel 19 for ADC0 T5INB I DA/B GPT12E Timer T5 Count/Gate Input Table 6 Pin Definitions and Functions (cont’d) Pin Symbol Ctrl. Type Function

XC2000 Family / Compact Line General Device Information Data Sheet 13 V1.2, 2012-07 17 P2.1 O0 / I DA/B Bit 1 of Port 2, General Purpose Input/Output ADC0_CH20 I DA/B Analog Input Channel 20 for ADC0 T5EUDB I DA/B GPT12E Timer T5 External Up/Down Control Input ESR1_5 I DA/B ESR1 Trigger Input 5 ERU_0A0 I DA/B External Request Unit Channel 0 Input A0 21 P2.2 O0 / I St/B Bit 2 of Port 2, General Purpose Input/Output ESR2_5 I St/B ESR2 Trigger Input 5 ERU_1A0 I St/B External Request Unit Channel 1 Input A0 22 P2.3 O0 / I St/B Bit 3 of Port 2, General Purpose Input/Output U0C0_DOUT O1 St/B USIC0 Channel 0 Shift Data Output CC2_CC16 O3 / I St/B CAPCOM2 CC16IO Capture Inp./ Compare Out. ESR2_0 I St/B ESR2 Trigger Input 0 U0C0_DX0E I St/B USIC0 Channel 0 Shift Data Input U0C1_DX0D I St/B USIC0 Channel 1 Shift Data Input 23 P2.4 O0 / I St/B Bit 4 of Port 2, General Purpose Input/Output U0C1_DOUT O1 St/B USIC0 Channel 1 Shift Data Output CC2_CC17 O3 / I St/B CAPCOM2 CC17IO Capture Inp./ Compare Out. ESR1_0 I St/B ESR1 Trigger Input 0 U0C0_DX0F I St/B USIC0 Channel 0 Shift Data Input 24 P2.5 O0 / I St/B Bit 5 of Port 2, General Purpose Input/Output U0C0_SCLK OUT O1 St/B USIC0 Channel 0 Shift Clock Output CC2_CC18 O3 / I St/B CAPCOM2 CC18IO Capture Inp./ Compare Out. U0C0_DX1D I St/B USIC0 Channel 0 Shift Clock Input ESR1_10 I St/B ESR1 Trigger Input 10 Table 6 Pin Definitions and Functions (cont’d) Pin Symbol Ctrl. Type Function

XC2000 Family / Compact Line General Device Information Data Sheet 14 V1.2, 2012-07 25 P2.6 O0 / I St/B Bit 6 of Port 2, General Purpose Input/Output U0C0_SELO O1 St/B USIC0 Channel 0 Select/Control 0 Output U0C1_SELO O2 St/B USIC0 Channel 1 Select/Control 1 Output CC2_CC19 O3 / I St/B CAPCOM2 CC19IO Capture Inp./ Compare Out. CLKIN1 I St/B Clock Signal Input 1 U0C0_DX2D I St/B USIC0 Channel 0 Shift Control Input ESR2_6 I St/B ESR2 Trigger Input 6 26 P2.7 O0 / I St/B Bit 7 of Port 2, General Purpose Input/Output U0C1_SELO O1 St/B USIC0 Channel 1 Select/Control 0 Output U0C0_SELO O2 St/B USIC0 Channel 0 Select/Control 1 Output CC2_CC20 O3 / I St/B CAPCOM2 CC20IO Capture Inp./ Compare Out. U0C1_DX2C I St/B USIC0 Channel 1 Shift Control Input ESR2_7 I St/B ESR2 Trigger Input 7 27 P2.8 O0 / I St/B Bit 8 of Port 2, General Purpose Input/Output U0C1_SCLK OUT O1 St/B USIC0 Channel 1 Shift Clock Output EXTCLK O2 St/B Programmable Clock Signal Output CC2_CC21 O3 / I St/B CAPCOM2 CC21IO Capture Inp./ Compare Out. U0C1_DX1D I St/B USIC0 Channel 1 Shift Clock Input 28 P2.9 O0 / I St/B Bit 9 of Port 2, General Purpose Input/Output U0C1_DOUT O1 St/B USIC0 Channel 1 Shift Data Output CC2_CC22 O3 / I St/B CAPCOM2 CC22IO Capture Inp./ Compare Out. C1 I St/B Configuration Pin 1 TCK_A I St/B DAP0/JTAG Clock Input Table 6 Pin Definitions and Functions (cont’d) Pin Symbol Ctrl. Type Function

XC2000 Family / Compact Line General Device Information Data Sheet 15 V1.2, 2012-07 29 P2.10 O0 / I St/B Bit 10 of Port 2, General Purpose Input/Output U0C1_DOUT O1 St/B USIC0 Channel 1 Shift Data Output U0C0_SELO O2 St/B USIC0 Channel 0 Select/Control 3 Output CC2_CC23 O3 / I St/B CAPCOM2 CC23IO Capture Inp./ Compare Out. U0C1_DX0E I St/B USIC0 Channel 1 Shift Data Input CAPINA I St/B GPT12E Register CAPREL Capture Input 30, P2.13 O0 / I St/B Bit 13 of Port 2, General Purpose Input/Output 31 P10.0 O0 / I St/B Bit 0 of Port 10, General Purpose Input/Output U0C1_DOUT O1 St/B USIC0 Channel 1 Shift Data Output CCU60_CC6 O2 St/B CCU60 Channel 0 Output CCU60_CC6 0INA IS t / B CCU60 Channel 0 Input ESR1_2 I St/B ESR1 Trigger Input 2 U0C0_DX0A I St/B USIC0 Channel 0 Shift Data Input U0C1_DX0A I St/B USIC0 Channel 1 Shift Data Input 32 P10.1 O0 / I St/B Bit 1 of Port 10, General Purpose Input/Output U0C0_DOUT O1 St/B USIC0 Channel 0 Shift Data Output CCU60_CC6 O2 St/B CCU60 Channel 1 Output CCU60_CC6 1INA IS t / B CCU60 Channel 1 Input U0C0_DX0B I St/B USIC0 Channel 0 Shift Data Input U0C0_DX1A I St/B USIC0 Channel 0 Shift Clock Input Table 6 Pin Definitions and Functions (cont’d) Pin Symbol Ctrl. Type Function

XC2000 Family / Compact Line General Device Information Data Sheet 16 V1.2, 2012-07 33 P10.2 O0 / I St/B Bit 2 of Port 10, General Purpose Input/Output U0C0_SCLK OUT O1 St/B USIC0 Channel 0 Shift Clock Output CCU60_CC6 O2 St/B CCU60 Channel 2 Output CCU60_CC6 2INA IS t / B CCU60 Channel 2 Input U0C0_DX1B I St/B USIC0 Channel 0 Shift Clock Input 34 P10.3 O0 / I St/B Bit 3 of Port 10, General Purpose Input/Output CCU60_COU T60 O2 St/B CCU60 Channel 0 Output U0C0_DX2A I St/B USIC0 Channel 0 Shift Control Input U0C1_DX2A I St/B USIC0 Channel 1 Shift Control Input 35 P10.4 O0 / I St/B Bit 4 of Port 10, General Purpose Input/Output U0C0_SELO O1 St/B USIC0 Channel 0 Select/Control 3 Output CCU60_COU T61 O2 St/B CCU60 Channel 1 Output U0C0_DX2B I St/B USIC0 Channel 0 Shift Control Input U0C1_DX2B I St/B USIC0 Channel 1 Shift Control Input ESR1_9 I St/B ESR1 Trigger Input 9 36 P10.5 O0 / I St/B Bit 5 of Port 10, General Purpose Input/Output U0C1_SCLK OUT O1 St/B USIC0 Channel 1 Shift Clock Output CCU60_COU T62 O2 St/B CCU60 Channel 2 Output U0C1_DX1B I St/B USIC0 Channel 1 Shift Clock Input 37 P10.6 O0 / I St/B Bit 6 of Port 10, General Purpose Input/Output U0C0_DOUT O1 St/B USIC0 Channel 0 Shift Data Output U0C0_DX0C I St/B USIC0 Channel 0 Shift Data Input CCU60_CTR APA IS t / B CCU60 Emergency Trap Input Table 6 Pin Definitions and Functions (cont’d) Pin Symbol Ctrl. Type Function

XC2000 Family / Compact Line General Device Information Data Sheet 17 V1.2, 2012-07 38 P10.7 O0 / I St/B Bit 7 of Port 10, General Purpose Input/Output U0C1_DOUT O1 St/B USIC0 Channel 1 Shift Data Output CCU60_COU T63 O2 St/B CCU60 Channel 3 Output U0C1_DX0B I St/B USIC0 Channel 1 Shift Data Input CCU60_CCP OS0A IS t / B CCU60 Position Input 0 T4INB I St/B GPT12E Timer T4 Count/Gate Input 39 P10.8 O0 / I St/B Bit 8 of Port 10, General Purpose Input/Output U0C0_MCLK OUT O1 St/B USIC0 Channel 0 Master Clock Output U0C1_SELO O2 St/B USIC0 Channel 1 Select/Control 0 Output CCU60_CCP OS1A IS t / B CCU60 Position Input 1 U0C0_DX1C I St/B USIC0 Channel 0 Shift Clock Input BRKIN_B IS t / B OCDS Break Signal Input T3EUDB I St/B GPT12E Timer T3 External Up/Down Control Input ESR2_11 I St/B ESR2 Trigger Input 11 40 P10.9 O0 / I St/B Bit 9 of Port 10, General Purpose Input/Output U0C0_SELO O1 St/B USIC0 Channel 0 Select/Control 4 Output U0C1_MCLK OUT O2 St/B USIC0 Channel 1 Master Clock Output CCU60_CCP OS2A IS t / B CCU60 Position Input 2 TCK_B I St/B DAP0/JTAG Clock Input T3INB I St/B GPT12E Timer T3 Count/Gate Input Table 6 Pin Definitions and Functions (cont’d) Pin Symbol Ctrl. Type Function

XC2000 Family / Compact Line General Device Information Data Sheet 18 V1.2, 2012-07 44 P10.10 O0 / I St/B Bit 10 of Port 10, General Purpose Input/Output U0C0_SELO O1 St/B USIC0 Channel 0 Select/Control 0 Output CCU60_COU T63 O2 St/B CCU60 Channel 3 Output U0C0_DX2C I St/B USIC0 Channel 0 Shift Control Input TDI_B I St/B JTAG Test Data Input U0C1_DX1A I St/B USIC0 Channel 1 Shift Clock Input 45 P10.12 O0 / I St/B Bit 12 of Port 10, General Purpose Input/Output U0C0_DOUT O2 St/B USIC0 Channel 0 Shift Data Output TDO_A OH St/B DAP1/JTAG Test Data Output SPD_0 I/OH St/B SPD Input/Output C0 I St/B Configuration Pin 0 U0C0_DX0D I St/B USIC0 Channel 0 Shift Data Input

46 XTAL2 O Sp/M Crystal Oscillator Amplifier Output

47 XTAL1 I Sp/M Crystal Oscillator Amplifier Input

To clock the device from an external source, drive XTAL1, while leaving XTAL2 unconnected. Voltages on XTAL1 must comply to the core supply voltage VDDIM. ESR2_9 I St/B ESR2 Trigger Input 9

48 PORST II n / B Power On Reset Input

A low level at this pin resets the XC2220U completely. A spike filter suppresses input pulses <10 ns. Input pulses >100 ns safely pass the filter. The minimum duration for a safe recognition should be 120 ns. An internal pullup device will hold this pin high when nothing is driving it. VAREF - PS/B Reference Voltage for A/D Converters ADC0

9 VAGND - PS/B Reference Ground for A/D Converters ADC0

Table 6 Pin Definitions and Functions (cont’d) Pin Symbol Ctrl. Type Function

XC2000 Family / Compact Line General Device Information Data Sheet 19 V1.2, 2012-07 18, VDDIM - PS/M Digital Core Supply Voltage for Domain M Decouple with a ceramic capacitor, see Data Sheet for details. All VDDIM pins must be connected to each other. 20, VDDPB - PS/B Digital Pad Supply Voltage for Domain B Connect decoupling capacitors to adjacent VDDP/VSS pin pairs as close as possible to the pins. 19, VSS - PS/-- Digital Ground All VSS pins must be connected to the ground-line or ground-plane. Table 6 Pin Definitions and Functions (cont’d) Pin Symbol Ctrl. Type Function

XC2000 Family / Compact Line General Device Information Data Sheet 20 V1.2, 2012-07

2.2 Identification Registers

The identification registers describe the current version of the XC2220U and of its modules. Table 7 XC2220U Identification Registers Short Name Value Address Notes SCU_IDMANUF 1820 H 00’F07EH SCU_IDCHIP 5001 H 00’F07CH SCU_IDMEM 3010 H 00’F07AH SCU_IDPROG 1313 H 00’F078H JTAG_ID 001D’7083 H ---

XC2000 Family / Compact Line Functional Description Data Sheet 21 V1.2, 2012-07

3 Functional Description

The architecture of the XC2220U combines advantages of RISC, CISC, and DSP processors with an advanced peripheral subsystem in a well-balanced design. On-chip memory blocks allow the design of co mpact systems-on-silicon with maximum performance suited for computing, control, and communication. The on-chip memory blocks (program co de memory and SRAM, dual-port RAM, data SRAM) and the generic peripherals are connected to the CPU by separate high-speed buses. Another bus, the LXBus, connects additional on-chip resources and external resources (see Figure 3). This bus structure enhances overall system performance by enabling the concurrent operation of several subsystems of the XC2220U. The block diagram gives an overview of the on-chip components and the advanced internal bus structure of the XC2220U. Figure 3 Block Diagram DPRAM CPU PMU DMU ADC0 Module 8-/10-/ 12-Bit RTC MCHK Interrupt & PEC LXBUS Controller DSRAM System Functions Clock, Reset, Power Control OCDS Debug Support Interrupt Bus Peripheral Data Bus Analog and Digital General Purpose IO (GPIO) Ports MC_U- SERIES _BLOCKDIAGRAM GPT Timers CC2 Module Chan. LXBus WWD CCU60 Module 3+1 Chan. USIC0 Module Chan. PSRAM Flash Memory IMB MAC Unit MPU

XC2000 Family / Compact Line Functional Description Data Sheet 22 V1.2, 2012-07

3.1 Memory Subsystem and Organization

The memory space of the XC2220U is conf igured in the von Neumann architecture. In this architecture all internal and extern al resources, including code memory, data memory, registers and I/O ports, are organized in the same linear address space. Table 8 XC2220U Memory Map 1) Address Area Start Loc. End Loc. Area Size 2) Notes IMB register space FF’FF00 H FF’FFFFH 256 bytes Reserved F0’0000 H FF’FEFFH < 1 Mbyte Minus IMB registers. Reserved for EPSRAM E8’1000 H EF’FFFFH 508 Kbytes Mirrors EPSRAM Emulated PSRAM E8’0000 H E8’0FFFH up to 4 Kbytes With Flash timing. Reserved for PSRAM E0’1000 H E7’FFFFH 508 Kbytes Mirrors PSRAM PSRAM E0’0000 H E0’0FFFH up to 4 Kbytes Program SRAM. Reserved for Flash C1’1000 H DF’FFFFH 1980 Kbytes Flash 0 C0’0000 H C1’0FFFH 68 Kbytes3) External memory area 40’0000H BF’FFFFH 8 Mbytes External IO area4) 21’0000H 3F’FFFFH 1984 Kbytes Reserved 20’B400 H 20’FFFFH 19 Kbytes USIC0 alternate regs. 20’B000 H 20’B3FFH 1 Kbytes Accessed via LXBus controller Reserved 20’4800 H 20’AFFFH 26 Kbytes USIC0 registers 20’4000 H 20’47FFH 2 Kbytes Accessed via LXBus controller Reserved 20’0000 H 20’3FFFH 16 Kbytes External memory area 01’0000H 1F’FFFFH 1984 Kbytes SFR area 00’FE00 H 00’FFFFH 0.5 Kbytes Dual-port RAM (DPRAM) 00’F600H 00’FDFFH 2 Kbytes Reserved for DPRAM 00’F200 H 00’F5FFH 1 Kbytes ESFR area 00’F000 H 00’F1FFH 0.5 Kbytes XSFR area 00’E000 H 00’EFFFH 4 Kbytes Data SRAM (DSRAM) 00’D800 H 00’DFFFH 2 Kbytes

XC2000 Family / Compact Line Functional Description Data Sheet 23 V1.2, 2012-07 This common memory space consists of 16 Mbytes organized as 256 segments of 64 Kbytes; each segment contains four data pages of 16 Kbytes. The entire memory space can be accessed bytewise or wordwise. Portions of the on-chip DPRAM and the register spaces (ESFR/SFR) additionally are directly bit addressable. The internal data memory areas and the Special Function Register areas (SFR and ESFR) are mapped into segment 0, the system segment. The Program Management Unit (PMU) handles all code fetches and, therefore, controls access to the program memories such as Flash memory and PSRAM. The Data Management Unit (DMU) handles al l data transfers and, therefore, controls access to the DSRAM and the on-chip peripherals. Both units (PMU and DMU) are connected to the high-speed system bus so that they can exchange data. This is required if operands are read from program memory, code or data is written to the PSRAM, code is fetched from external memory, or data is read from or written to external resources. These include peripherals on the LXBus such as USIC or MultiCAN. The system bus allows concurrent two-way communication for maximum transfer performance. 4 Kbytes of on-chip Program SRAM (PSRAM) are provided to store user code or data. The PSRAM is accessed via the PMU and is optimized for code fetches. A section of the PSRAM with programmable size can be write-protected. Reserved for DSRAM 00’8000 H 00’D7FFH 22 Kbytes External memory area 00’0000H 00’7FFFH 32 Kbytes 1) Accesses to the shaded areas are reserved. In devices with external bus interface these accesses generate external bus accesses. 2) The areas marked with “<” are slightly smaller than indicated, see column “Notes”. 3) The uppermost 4-Kbyte sector of the first Flash segment is reserved for internal use (C0’F000H to C0’FFFFH). 4) Several pipeline optimizations are not active within the external IO area. Table 8 XC2220U Memory Map (cont’d)1) (cont’d) Address Area Start Loc. End Loc. Area Size 2) Notes

XC2000 Family / Compact Line Functional Description Data Sheet 24 V1.2, 2012-07 2 Kbytes of on-chip Data SRAM (DSRAM) are used for storage of general user data. The DSRAM is accessed via a separate interface and is optimized for data access.

2 Kbytes of on-chip Dual-Port RAM (DPRAM) provide storage for user-defined

variables, for the system stack, and for general purpose register banks. A register bank can consist of up to 16 word-wide (R0 to R15) and/or byte-wide (RL0, RH0, …, RL7, RH7) General Purpose Registers (GPRs). The upper 256 bytes of the DPRAM are directly bit addressable. When used by a GPR, any location in the DPRAM is bit addressable. 1024 bytes (2 × 512 bytes) of the address space are reserved for the Special Function Register areas (SFR space and ESFR space). SFRs are word-wide registers which are used to control and monitor functions of the different on-chip units. Unused SFR addresses are reserved for future members of the XC2000 Family. In order to ensure upward compatibility they should either not be accessed or written with zeros. The on-chip Flash memory stores code, constant data, and control data. The on-chip Flash memory consist of 1 module of 64 Kb ytes. Each module is organized in 4-Kbyte sectors. The uppermost 4-Kbyte sector of segment 0 (located in Flash module 0) is used internally to store operation control parameters and protection information. Each sector can be separately write protected 1), erased and programmed (in blocks of 128 Bytes). The complete Flash area can be read-protected. A user-defined password sequence temporarily unlocks protected areas. The Flas h modules combine 128-bit read access with protected and efficient writing algorithms for programming and erasing. Dynamic error correction provides extremely high read data security for all read access operations. Access to different Flash modules can be executed in parallel. For Flash parameters, please see Section 4.6. Memory Content Protection The contents of on-chip memories can be protected against soft errors (induced e.g. by radiation) by activating the parity mechanism or the Error Correction Code (ECC). The parity mechanism can detect a single-bit error and prevent the software from using incorrect data or executing incorrect instructions. The ECC mechanism can detect and automatically correct single-bit errors. This supports the stable operation of the system. It is strongly recommended to activate the ECC mechanism wherever possible because this dramatically increases the robustness of an application against such soft errors. 1) To save control bits, sectors are clustered for protection purposes, they remain separate for programming/erasing.

XC2000 Family / Compact Line Functional Description Data Sheet 25 V1.2, 2012-07

3.2 Central Processing Unit (CPU)

The core of the CPU consists of a 5-stage execution pipeline with a 2-stage instruction- fetch pipeline, a 16-bit arithmetic and logi c unit (ALU), a 32-bit/40-bit multiply and accumulate unit (MAC), a register-file providing three register banks, and dedicated SFRs. The ALU features a multiply-and-div ide unit, a bit-mask generator, and a barrel shifter. Figure 4 CPU Block Diagram DPRAM CPU IPIP RF GPRs R14 R15 GPRs R14 R15 IFU Injection/ Exception Handler ADU MAC mca04917_x.vsd CPUCON1 CPUCON2 CSP IP Return StackFIFO Branch Unit Prefetch Unit VECSEG TFR +/- IDX0 IDX1 QX0 QX1 QR0 QR1 DPP0 DPP1 DPP2 DPP3 SPSEG SP STKOV STKUN +/- MRW MCW MSW MAL +/- MAH Multiply Unit ALU Division Unit Multiply Unit Bit-Mask-Gen. Barrel-Shifter +/- MDC PSW MDH ZEROS MDL ONES GPRs R14 R15 CP WB Buffer 2-Stage Prefetch Pipeline 5-Stage Pipeline GPRs R14 R15 PMU DMU DSRAM EBC Peripherals PSRAM Flash/ROM

XC2000 Family / Compact Line Functional Description Data Sheet 26 V1.2, 2012-07 With this hardware most XC2220U instructions are executed in a single machine cycle of 15.2 ns @ 66-MHz CPU clock. For example, shift and rotate instructions are always processed during one ma chine cycle, no matter how m any bits are shifted. Also, multiplication and most MA C instructions execute in one cycle. All multiple-cycle instructions have been optimized so that they can be executed very fast; for example, a 32-/16-bit division is started within 4 cycle s while the remaining cycles are executed in the background. Another pipeline optimization, the branch target prediction, eliminates the execution time of branch instructions if the prediction was correct. The CPU has a register context consisting of up to three register banks with 16 word- wide GPRs each at its disposal. One of these register banks is physically allocated within the on-chip DPRAM area. A Context Pointer (CP) register determines the base address of the active register bank accessed by the CPU at any time. The number of these register bank copies is only restricted by the available internal RAM space. For easy parameter passing, a register bank may overlap others. A system stack of up to 32 Kwords is provided for storage of temporary data. The system stack can be allocated to any location within the address space (preferably in the on-chip RAM area); it is accessed by the CPU with the stack pointer (SP) register. Two separate SFRs, STKOV and STKUN, are implicitly compared with the stack pointer value during each stack access to detect stack overflow or underflow. The high performance of the CPU hardware implementation can be best utilized by the programmer with the highly efficient XC2220U instruction set. This includes the following instruction classes:

  • Standard Arithmetic Instructions
  • DSP-Oriented Arithmetic Instructions
  • Logical Instructions
  • Boolean Bit Manipulation Instructions
  • Compare and Loop Control Instructions
  • Shift and Rotate Instructions
  • Prioritize Instruction
  • Data Movement Instructions
  • System Stack Instructions
  • Jump and Call Instructions
  • Return Instructions
  • System Contro l Instructions
  • Miscellaneous Instructions The basic instruction length is either 2 or 4 bytes. Possible operand types are bits, bytes and words. A variety of direct, indirect or immediate addressing modes are provided to specify the required operands.

XC2000 Family / Compact Line Functional Description Data Sheet 27 V1.2, 2012-07

3.3 Memory Protection Unit (MPU)

The XC2220U’s Memory Protection Unit (MPU) protects user-specified memory areas from unauthorized read, write, or instruct ion fetch accesses. The MPU can protect the whole address space including the peripheral area. This completes established mechanisms such as the register securi ty mechanism or stack overrun/underrun detection. Four Protection Levels support flexible system programming wh ere operating system, low level drivers, and applications run on separate levels. Each protection level permits different access restrictions for instructions and/or data. Every access is checked (if the MPU is enabled) and an access violating the permission rules will be marked as invalid and leads to a protection trap. A set of protection registers for each protec tion level specifies the address ranges and the access permissions. Applications requ iring more than 4 protection levels can dynamically re-program the protection registers.

3.4 Memory Checker Module (MCHK)

The XC2220U’s Memory Checker Module calculates a checksum (fractional polynomial division) on a block of data, often called Cyclic Redundancy Code (CRC). It is based on a 32-bit linear feedback shift register and may, therefore, also be used to generate pseudo-random numbers. The Memory Checker Module is a 16-bit parallel input signature compression circuitry which enables error detection within a block of data stored in me mory, registers, or communicated e.g. via serial communication lines. It reduces the probability of error masking due to repeated error patterns by calculating the signature of blocks of data. The polynomial used for operation is configurable, so most of the commonly used polynomials may be used. Also, the block size for generating a CRC result is configurable via a local counter. An interrupt may be generated if testing the current data block reveals an error. An autonomous CRC compare circuitry is included to enable redundant error detection, e.g. to enable higher safety integrity levels. The Memory Checker Module provides enhanced fault detection (beyond parity or ECC) for data and instructions in volatile and non volatile memories. This is especially important for the safety and reliability of embedded systems.

XC2000 Family / Compact Line Functional Description Data Sheet 28 V1.2, 2012-07

3.5 Interrupt System

The architecture of the XC2220U supports several mechanisms for fast and flexible response to service requests; these can be generated from various sources internal or external to the microcontroller. Any of these interrupt requests can be programmed to be serviced by the Interrupt Controller or by the Peripheral Event Controller (PEC). Using a standard interrupt service the curr ent program execution is suspended and a branch to the interrupt vector table is performed. With the PEC just one cycle is ‘stolen’ from the current CPU activity to perform the PEC service. A PEC service implies a single byte or word data transfer between any two memory locations with an additional increment of either the PEC source pointer, the destination pointer, or both. An individual PEC transfer counter is implicitly decre mented for each PEC service except when performing in the continuous transfer mode. When this counter reaches zero, a standard interrupt is performed to the corresponding source-related vector location. PEC services are particularly well suited to supporting the transmission or reception of blocks of data. The XC2220U has eight PEC channels, each with fast interrupt-driven data transfer capabilities. With a minimum interrupt response time of 7/11 1) CPU clocks, the XC2220U can react quickly to the occurrence of non-deterministic events. Interrupt Nodes and Source Selection The interrupt system provides 46 physica l nodes with separate control register containing an interrupt request flag, an interrupt enable flag and an interrupt priority bit field. Most interrupt sources are assigned to a dedicated node. A particular subset of interrupt sources shares a set of nodes. The source selection can be programmed using the interrupt source selection (ISSR) registers. External Request Unit (ERU) A dedicated External Request Unit (ERU) is provided to route and preprocess selected on-chip peripheral and external interrupt requests. The ERU features 4 programmable input channels with event trigger logic (ETL ) a routing matrix and 4 output gating units (OGU). The ETL features rising edge, falli ng edge, or both edges event detection. The OGU combines the detected interrupt ev ents and provides filtering capabilities depending on a programmable pattern match or miss. Trap Processing The XC2220U provides efficient mechanisms to identify and process exceptions or error conditions that arise during run-time, the so-called ‘Hardware Traps’. A hardware trap causes an immediate system reaction similar to a standard interrupt service (branching 1) Depending if the jump cache is used or not.

XC2000 Family / Compact Line Functional Description Data Sheet 29 V1.2, 2012-07 to a dedicated vector table location). The occurrence of a hardware trap is also indicated by a single bit in the trap flag register (TFR). Unless another higher-priority trap service is in progress, a hardware trap will interrupt any ongoing program execution. In turn, hardware trap services can normally not be interrupted by standard or PEC interrupts. Depending on the package option up to 3 External Service Request (ESR) pins are provided. The ESR unit processes their i nput values and allows to implement user controlled trap functions (System Requests SR0 and SR1). In this way reset, wakeup and power control can be efficiently realized. Software interrupts are supported by the ‘TRAP’ instruction in combination with an individual trap (interrupt) number. Alternatively to emulate an interrupt by software a program can trigger interrupt requests by wr iting the Interrupt Request (IR) bit of an interrupt control register.

3.6 On-Chip Debug Support (OCDS)

The On-Chip Debug Support system built into the XC2220U provides a broad range of debug and emulation features. User software running on the XC2220U can be debugged within the target system environment. The OCDS is controlled by an external debugging device via the debug interface. This consists of the 2-pin Device Access Port (DAP) or of the 1-pin Single Pin DAP (SPD) or of the JTAG port conforming to IEEE-1149. The debug interface can be completed with an optional break interface. The debugger controls the OCDS with a set of dedicated registers accessible via the debug interface (SPD, DAP or JTAG). In addition the OCDS system can be controlled by the CPU, e.g. by a monitor program. An injection interface allows the execution of OCDS-generated instructions by the CPU. Multiple breakpoints can be triggered by on-chip hardware, by software, or by an external trigger input. Single stepping is su pported, as is the in jection of arbitrary instructions and read/write access to the complete internal address space. A breakpoint trigger can be answered with a CPU halt, a mo nitor call, a data transfer, or/and the activation of an external signal. Tracing of data can be obtained via the debug interface, or via the external bus interface for increased performance. Tracing of program execution is supported by the XC2000 Family emulation device. The SPD interface uses one interface signal, DAP interface uses two interface signals, the JTAG interface uses four interface signals, to communicate with external circuitry. The debug interface can be amended with two optional break lines.

XC2000 Family / Compact Line Functional Description Data Sheet 30 V1.2, 2012-07

3.7 Capture/Compare Unit (CC2)

The CAPCOM unit supports generation and control of timing sequences on up to 16 channels with a maximum resolution of one system clock cycle (eight cycles in staggered mode). The CAPCOM unit is typically used to handle high-speed I/O tasks such as pulse and waveform generation, pulse width modulation (PWM), digital to analog (D/A) conversion, software timing, or time recording with respect to external events. Two 16-bit timers with reload registers provide two independent time bases for the capture/compare register array. The input clock for the timers is programmable to several prescaled values of the internal system clock, or may be derived from an overflow/underflow of timer T6 in module GPT2. This provides a wide range of variation for the timer period and resolution and allows precise adjustments to the application specific requirements. In addition, external count inputs allow event scheduling for the captur e/compare registers relative to external events. The capture/compare register array cont ains 16 dual purpose capture/compare registers, each of which may be individual ly allocated to either CAPCOM timer and programmed for capture or compare function. All registers have each one port pin associated with it which serves as an input pin for triggering the capture function, or as an output pin to indicate the occurrence of a compare event. When a capture/compare register has been selected for capture mode, the current contents of the allocated timer will be latched (‘captured’) into the capture/compare register in response to an external event at the port pin which is associated with this register. In addition, a specific interrupt request for this capture/compare register is generated. Either a positive, a negative, or both a positive and a negative external signal transition at the pin can be selected as the triggering event. The contents of all registers which have been selected for one of the five compare modes are continuously compared with the contents of the allocated timers. When a match occurs between the timer value and the value in a capture/compare register, specific actions will be taken based on the selected compare mode. Table 9 Compare Modes Compare Modes Function Mode 0 Interrupt-only compare mode; Several compare interrupts per timer period are possible Mode 1 Pin toggles on each compare match; Several compare events per timer period are possible

XC2000 Family / Compact Line Functional Description Data Sheet 31 V1.2, 2012-07 When a capture/compare register has been selected for capture mode, the current contents of the allocated timer will be latched (‘captured’) into the capture/compare register in response to an external event at the port pin associated with this register. In addition, a specific interrupt request for this capture/compare register is generated. Either a positive, a negative, or both a positive and a negative external signal transition at the pin can be selected as the triggering event. The contents of all registers selected for one of the five compare modes are continuously compared with the contents of the allocated timers. When a match occurs between the timer value and the value in a capture/compare register, specific actions will be taken based on the compare mode selected. Mode 2 Interrupt-only compare mode; Only one compare interrupt per timer period is generated Mode 3 Pin set ‘1’ on match; pin reset ‘0’ on compare timer overflow; Only one compare event per timer period is generated Double Register Mode Two registers operate on one pin; Pin toggles on each compare match; Several compare events per timer period are possible Single Event Mode Generates single edges or pulses; Can be used with any compare mode Table 9 Compare Modes (cont’d) Compare Modes Function

XC2000 Family / Compact Line Functional Description Data Sheet 32 V1.2, 2012-07 Figure 5 CAPCOM Unit Block Diagram Sixteen 16-bit Capture/ Compare Registers Mode Control (Capture or Compare ) Input Control Input Control MC_CAPCOM2_BLOCKDIAG CC16IRQ CC31IRQ CC17IRQ T7IRQ T8IRQ CC16IO CC17IO T7IN T6OUF fCC T6OUF fCC Reload Reg . T7REL Timer T7 Timer T8 Reload Reg . T8REL CC31IO

XC2000 Family / Compact Line Functional Description Data Sheet 33 V1.2, 2012-07

3.8 Capture/Compare Units CCU6x

The XC2220U types feature the CCU60 unit. CCU6 is a high-resolution capture and compare unit with application-specific modes. It provides inputs to start the timers synchr onously, an important feature in devices with several CCU6 modules. The module provides two independent timers (T12, T13), that can be used for PWM generation, especially for AC motor control. Additionally, special control modes for block commutation and multi-phase machines are supported. Timer 12 Features

  • Three capture/compare channels, where each channel can be used either as a capture or as a compare channel.
  • Supports generation of a three-phase PWM (six outputs, individual signals for high- side and low-side switches)
  • 16-bit resolution, maximum count frequency = peripheral clock
  • Dead-time control for each channel to avoid short circuits in the power stage
  • Concurrent update of the required T12/13 registers
  • Center-aligned and edge-aligned PWM can be generated
  • Single-shot mode supported
  • Many interrupt request sources
  • Hysteresis-like control mode
  • Automatic start on a HW event (T 12HR, for synchronization purposes) Timer 13 Features
  • One independent compare channel with one output
  • 16-bit resolution, maximum count frequency = peripheral clock
  • Can be synchronized to T12
  • Interrupt generation at period match and compare match
  • Single-shot mode supported
  • Automatic start on a HW event (T 13HR, for synchronization purposes) Additional Features
  • Block commutation for brushless DC drives implemented
  • Position detection via Hall sensor pattern
  • Automatic rotational speed measurement for block commutation
  • Integrated error handling
  • Fast emergency stop without CPU load via external signal (CTRAP
  • Control modes for multi-channel AC drives
  • Output levels can be selected and adapted to the power stage

XC2000 Family / Compact Line Functional Description Data Sheet 34 V1.2, 2012-07 Figure 6 CCU6 Block Diagram Timer T12 can work in capture and/or compare mode for its three channels. The modes can also be combined. Timer T13 can work in compare mode only. The multi-channel control unit generates output patterns that can be modulated by timer T12 and/or timer T13. The modulation sources can be selected and combined for signal modulation. mc_ccu6_blockdiagram.vsd Channel 0 Channel 1 Channel 2 T12 Dead- time Control Input / Output Control CC62 COUT62 CC61 COUT61 CC60 COUT60 COUT63 CTRAP Channel 3T13 CCPOS0 2221 start compare capt ur e Multi- channel Control Trap Control compare com par e com par e com par e trap i nput CCPOS1 CCPOS2 output select output select H a ll in p u t CCU6 Module Kernel fSYS Interrupts TxHR

XC2000 Family / Compact Line Functional Description Data Sheet 35 V1.2, 2012-07

3.9 General Purpose Timer (GPT12E) Unit

The GPT12E unit is a very flexible multif unctional timer/counter structure which can be used for many different timing tasks such as event timing and counting, pulse width and duty cycle measurements, pulse generation, or pulse multiplication. The GPT12E unit incorporates five 16-bit timers organized in two separate modules, GPT1 and GPT2. Each timer in each module may either operate independently in a number of different modes or be concatenated with another timer of the same module. Each of the three timers T2, T3, T4 of module GPT1 can be configured individually for one of four basic modes of operation: Time r, Gated Timer, Counter, and Incremental Interface Mode. In Timer Mode, the input cl ock for a timer is derived from the system clock and divided by a programmable prescaler. Counter Mode allows timer clocking in reference to external events. Pulse width or duty cycle measurement is supported in Gated Timer Mode, where the operation of a timer is controlled by the ‘gate’ level on an external input pin. For these purposes each timer has one associated port pin (TxIN) which serves as a gate or clock input. The maximum resolution of the timers in module GPT1 is 4 system clock cycles. The counting direction (up/down) for each timer can be programmed by software or altered dynamically by an external signal on a port pin (TxEUD), e.g. to facilitate position tracking. In Incremental Interface Mode the GPT1 ti mers can be directly connected to the incremental position sensor signals A and B through their respective inputs TxIN and TxEUD. Direction and counting signals are internally derived from these two input signals, so that the contents of the respective timer Tx corresponds to the sensor position. The third position sensor signal TOP0 can be connected to an interrupt input. Timer T3 has an output toggle latch (T3OTL ) which changes its state on each timer overflow/underflow. The state of this latch may be output on pin T3OUT e.g. for time out monitoring of external hardware components. It may also be used internally to clock timers T2 and T4 for measuring long time periods with high resolution. In addition to the basic operating modes, T2 and T4 may be configured as reload or capture register for timer T3. A timer used as capture or reload register is stopped. The contents of timer T3 is captured into T2 or T4 in response to a signal at the associated input pin (TxIN). Timer T3 is reloaded with th e contents of T2 or T4, triggered either by an external signal or a selectable state tr ansition of its toggle latch T3OTL. When both T2 and T4 are configured to alternately reload T3 on opposite state transitions of T3OTL with the low and high times of a PWM signal, this signal can be continuously generated without software intervention. Note: Signals T2IN, T2EUD, T4EUD, T6OUT, T6IN and T6EUD are not connected to pins.

XC2000 Family / Compact Line Functional Description Data Sheet 36 V1.2, 2012-07 Figure 7 Block Diagram of GPT1 MC_GPT_BLOCK1 Aux. Timer T2 2n:1 Mode Control Capture U/D Basic ClockfGPT T3CON.BPS1 T3OTL T3OUT Toggle Latch T2IN T2EUD Reload Core Timer T3 Mode Control T3IN T3EUD U/D Interrupt Request (T3IRQ) Mode Control U/D Aux. Timer T4T4EUD T4IN Reload Capture Interrupt Request (T4IRQ) Interrupt Request (T2IRQ)

XC2000 Family / Compact Line Functional Description Data Sheet 37 V1.2, 2012-07 With its maximum resolution of 2 system clock cycles, the GPT2 module provides precise event control and time measurement. It includes two timers (T5, T6) and a capture/reload register (CAPREL). Both timers can be clocked with an input clock which is derived from the CPU clock via a programmable prescaler or with external signals. The counting direction (up/down) for each timer can be programmed by software or altered dynamically with an external signal on a port pin (TxEUD). Concatenation of the timers is supported with the output toggle latch (T6OTL) of timer T6, which changes its state on each timer overflow/underflow. The state of this latch may be used to clock timer T5, and/or it may be output on pin T6OUT. The overflows/underflows of timer T6 can also be used to clock the CAPCOM2 timers and to initiate a reload from the CAPREL register. The CAPREL register can capture the contents of timer T5 based on an external signal transition on the corresponding port pin (CAPIN); timer T5 may optionally be cleared after the capture procedure. This allows the XC2220U to measure absolute time differences or to perform pulse multiplication without software overhead. The capture trigger (timer T5 to CAPREL ) can also be generated upon transitions of GPT1 timer T3 inputs T3IN and/or T3EUD. This is especially advantageous when T3 operates in Incremental Interface Mode.

XC2000 Family / Compact Line Functional Description Data Sheet 38 V1.2, 2012-07 Figure 8 Block Diagram of GPT2 MC_GPT_BLOCK2 GPT2 Timer T5 2n:1 Mode Control GPT2 CAPREL T3IN/ T3EUD CAPREL Mode Control Mode Control Reload Clear U/D Capture Clear U/DT5IN CAPIN Interrupt Request (T5IRQ) Interrupt Request (T6IRQ) Interrupt Request (CRIRQ) Basic ClockfGPT T6CON.BPS2 T6IN GPT2 Timer T6 T6OTL T6OUT T6OUF Toggle FF T6EUD T5EUD

XC2000 Family / Compact Line Functional Description Data Sheet 39 V1.2, 2012-07

3.10 Real Time Clock

The Real Time Clock (RTC) module of the XC2220U can be clocked with a clock signal selected from internal sources or external sources (pins). The RTC basically consists of a chain of divider blocks:

  • Selectable 32:1 and 8:1 dividers (on - off)
  • The reloadable 16-bit timer T14
  • The 32-bit RTC timer block (accessible via registers RTCH and RTCL) consisting of: – a reloadable 10-bit timer – a reloadable 6-bit timer – a reloadable 6-bit timer – a reloadable 10-bit timer All timers count up. Each timer can generat e an interrupt request. All requests are combined to a common node request. Figure 9 RTC Block Diagram Note: The registers associated with the RTC are only affected by a power reset. CNT-Register REL-Register

10 Bits6 Bits6 Bits10 BitsT14

T14REL 10 Bits6 Bits6 Bits10 Bits MUX 8: REFCLK

XC2000 Family / Compact Line Functional Description Data Sheet 40 V1.2, 2012-07 The RTC module can be used for different purposes:

  • System clock to determine the current time and date
  • Cyclic time-based interrupt, to provide a system time tick independent of CPU frequency and other resources
  • 48-bit timer for long-term measurements
  • Alarm interrupt at a defined time

XC2000 Family / Compact Line Functional Description Data Sheet 41 V1.2, 2012-07

3.11 A/D Converters

For analog signal measurement, a 12-bit A/D converters (ADC0) with 10 multiplexed input channels and a sample and hold circuit have been integrated on-chip. Conversions use the successive approximation method. The sample time (to charge the capacitors) and the conversion time are programmable so that they can be adjusted to the external circuit. The A/D converters can also operate in 8-bit and 10-bit conversion mode, further reducing the conversion time. Several independent conversion result regist ers, selectable inte rrupt requests, and highly flexible conversion sequences provide a high degree of programmability to meet the application requirements. For applications that require more analog input channels, external analog multiplexers can be controlled automatically. For app lications that require fewer analog input channels, the remaining channel inputs can be used as digital input port pins. The A/D converters of the XC2220U support two types of request sources which can be triggered by several internal and external events.

  • Parallel requests are activated at the sa me time and then executed in a predefined sequence.
  • Queued requests are executed in a user-defined sequence. In addition, the conversion of a specific channel can be inserted into a running sequence without disturbing that sequence. All requests are arbitrated according to the priority level assigned to them. Data reduction features reduce the number of required CPU access operations allowing the precise evaluation of analog inputs (high conversion rate) even at a low CPU speed. Result data can be reduced by limit checking or accumulation of results. Two cascadable filters build the hardware to generate a configurable moving average. The Peripheral Event Controller (PEC) can be used to control the A/D converters or to automatically store conversion results to a table in memory for later evaluation, without requiring the overhead of enter ing and exiting interrupt routines for each data transfer. Each A/D converter contains eight result registers which can be concatenated to build a result FIFO. Wait-f or-read mode can be enabled for each result register to prevent the loss of conversion data. In order to decouple analog inputs from digi tal noise and to avoid input trigger noise, those pins used for analog input can be disconnected from the digital input stages. This can be selected for each pin separately with the Port x Digital Input Disable registers. The Auto-Power-Down feature of the A/D converters minimizes the power consumption when no conversion is in progress. Broken wire detection for each channel and a multiplexer test mode provide information to verify the proper operation of the analog signal sources (e.g. a sensor system).

XC2000 Family / Compact Line Functional Description Data Sheet 42 V1.2, 2012-07

3.12 Universal Serial Interf ace Channel Modules (USIC)

The XC2220U features the USIC module USIC0. The module provides two serial communication channels. The Universal Serial Interface Channel (USIC) module is based on a generic data shift and data storage structure which is identi cal for all supported serial communication protocols. Each channel supports complete full-duplex operation with a basic data buffer structure (one transmit buffer and two receive buffer stages). In addition, the data handling software can use FIFOs. The protocol part (generation of shift clock/da ta/control signals) is independent of the general part and is handled by protocol-specific preprocessors (PPPs). The USIC’s input/output lines are connected to pins by a pin routing unit. The inputs and outputs of each USIC channel can be assigned to different interface pins, providing great flexibility to the application software. All assignments can be made during runtime. Figure 10 General Structure of a USIC Module The regular structure of the USIC module brings the following advantages:

  • Higher flexibility through configuration wi th same look-and-feel for data management
  • Reduced complexity for low-level dr ivers serving different protocols
  • Wide range of protocols with improved performances (baud rate, buffer handling) USIC_basic.vsd Bus Interface DBU DBU Control 0 Control 1 DSU DSU PPP_A PPP_B PPP_C PPP_D PPP_A PPP_B PPP_C PPP_D Pin Routing Shell Buffer & Shift Structure Protocol Preprocessors PinsBus fsys Fractional Dividers Baud rate Generators

XC2000 Family / Compact Line Functional Description Data Sheet 43 V1.2, 2012-07 Target Protocols Each USIC channel can receive and transmit data frames with a selectable data word width from 1 to 16 bits in each of the following protocols:

  • UART (asynchronous serial channel) – module capability: maximum baud rate = fSYS / 4 – data frame length programmable from 1 to 63 bits – MSB or LSB first
  • LIN Support (Local Interconnect Network) – module capability: maximum baud rate = fSYS / 16 – checksum generation under software control – baud rate detection possible by built-in capture event of baud rate generator
  • SSC/SPI (synchronous serial channel with or without data buffer) – module capability: maximum baud rate = fSYS / 2, limited by loop delay – number of data bits programm able from 1 to 63, more with explicit stop condition – MSB or LSB first – optional control of slave select signals
  • IIC (Inter-IC Bus) – supports baud rates of 100 kbit/s and 400 kbit/s
  • IIS (Inter-IC Sound Bus) – module capability: maximum baud rate = fSYS / 2 Note: Depending on the selected functions (such as digital filters, input synchronization stages, sample point adjustment, etc.), the maximum achievable baud rate can be limited. Please note that there may be additional delays, such as internal or external propagation delays and driver delays (e.g. for collision detection in UART mode, for IIC, etc.).

3.13 System Timer

The System Timer consists of a programmable prescaler and two concatenated timers (10 bits and 6 bits). Both timers can gener ate interrupt requests. The clock source can be selected and the timers can also run during power reduction modes. Therefore, the System Timer enables the software to maintain the current time for scheduling functions or for the implementation of a clock.

3.14 Window Watchdog Timer

The Window Watchdog Timer is one of the fail-safe mechanisms which have been implemented to prevent the controller from malfunctioning for longer periods of time. The Window Watchdog Timer is always enabled after an application reset of the chip. It can be disabled and enabled at any time by executing the instru ctions DISWDT and ENWDT respectively. The software has to service the Window Watchdog Timer before

XC2000 Family / Compact Line Functional Description Data Sheet 44 V1.2, 2012-07 it overflows. If this is not the case because of a hardware or software failure, the Window Watchdog Timer overflows, generating a reset request. The Window Watchdog Timer has a ‘programmable window boundary’, it disallows refresh during the Window Watchdog Timer’s count-up. A refresh during this window- boundary will cause the Window Watchdog Timer to also generate a reset request. The Window Watchdog Timer is a 16-bit timer clocked with either the system clock or the independent wake-up oscillator clock, divided by 16,384 or 256. The Window Watchdog Timer register is set to a prespecified reload value (stored in WDTREL) in order to allow further variation of the monitored time interval. Each time it is serviced by the application software, the Window Watchdog Timer is reloaded. When clocked by fSYS = 66 MHz, time intervals between 15.2 ns and 16.3 s can be monitored. When clocked by fWU = 500 kHz, time intervals between 2.0 µs and 2147.5 s can be monitored. The default Watchdog Timer interval after power-up is 0.13 s (@ fWU = 500 kHz).

3.15 Clock Generation

The Clock Generation Unit can generate the system clock signal fSYS for the XC2220U from a number of external or internal clock sources:

  • External clock signals with pad voltage or core voltage levels
  • External crystal or resonator using the on-chip oscillator
  • On-chip clock source for oper ation without crystal/resonator
  • Wake-up clock (ultra-low-power) to further reduce power consumption The programmable on-chip PLL with multiple prescalers generates a clock signal for maximum system performance from standard crystals, a clock input signal, or from the on-chip clock source. See also Section 4.7.2. The Oscillator Watchdog (OWD) generates an interrupt if the crystal oscillator frequency falls below a certain limit or stops completely. In this case, the system can be supplied with an emergency clock to enable operation even after an external clock failure. All available clock signals can be output on the EXTCLK pin.

XC2000 Family / Compact Line Functional Description Data Sheet 45 V1.2, 2012-07

3.16 Parallel Ports

The XC2220U provides up to 33 I/O lines wh ich are organized into 3 input/output ports and 1 input port. All port lines are bit-addr essable, and all input/output lines can be individually (bit-wise) configured via port control registers. This configuration selects the direction (input/output), push/pull or open-drain operation, activation of pull devices, and edge characteristics (shape) and driver char acteristics (output current) of the port drivers. The I/O ports are true bidirectional ports which are switched to high impedance state when configured as inputs. During the internal reset, all port pins are configured as inputs without pull devices active. All port lines have alternate input or out put functions associat ed with them. These alternate functions can be programmed to be assigned to various port pins to support the best utilization for a given application. For this reason, certain functions appear several times in Table 10. All port lines that are not used for alternate functions may be used as general purpose I/O lines. Table 10 Summary of the XC2220U’s Ports Group Width I/O Connected Modules P2 12 I/O Analog inputs, ADC, CC 2, DAP/JTAG, GPT12E, SCU, USIC P5 6 I Analog inputs, CCU6, JTAG, GPT12E, CC2 P6 3 I/O Analog inputs, ADC, JTAG, GPT12E P10 12 I/O CCU6, GPT12E, DAP/JTAG, SPD, USIC

XC2000 Family / Compact Line Functional Description Data Sheet 46 V1.2, 2012-07

3.17 Power Management

The XC2220U provides the means to control the power it consumes either at a given time or averaged over a certain duration. Two mechanisms can be used (and partly in parallel):

  • Clock Generation Management controls the frequency of internal and external clock signals. Clock signals for currently inactive parts of logic are disabled automatically. The user can drastically reduce the consumed power by reducing the XC2220U system clock frequency. External circuits can be controlled using the programmable frequency output EXTCLK.
  • Peripheral Management permits temporary disabling of peripheral modules. Each peripheral can be disabled and enabled separ ately. The CPU can be switched off while the peripherals can continue to operate. Wake-up from power reduction modes can be triggered either externally with signals generated by the external system, or inter nally by the on-chip wake-up timer. This supports intermittent operat ion of the XC2220U by generating cyclic wake-up signals. Full performance is available to quickly react to action requests while the intermittent sleep phases greatly reduce the average system power consumption. Note: When selecting the supply voltage and the clock source and generation method, the required parameters must be carefully written to the respective bit fields, to avoid unintended intermediate states. Recommended sequences are provided which ensure the intended operation of power supply system and clock system. Please refer to the Programmer’s Guide.

XC2000 Family / Compact Line Functional Description Data Sheet 47 V1.2, 2012-07

3.18 Instruction Set Summary

Table 11 lists the instructions of the XC2220U. The addressing modes that can be used with a specific instruction, the function of the instructions, parameters for conditional execution of in structions, and the opcodes for each instruction can be found in the “Instruction Set Manual”. This document also provides a detailed description of each instruction. Table 11 Instruction Set Summary Mnemonic Description Bytes ADD(B) Add word (byte) operands 2 / 4 ADDC(B) Add word (byte) operands with Carry 2 / 4 SUB(B) Subtract word (byte) operands 2 / 4 SUBC(B) Subtract word (byte) operands with Carry 2 / 4 MUL(U) (Un)Signed multiply direct GPR by direct GPR (16- × 16-bit) DIV(U) (Un)Signed divide register MDL by direct GPR (16-/16-bit) 2 DIVL(U) (Un)Signed long divide reg. MD by direct GPR (32-/16-bit) 2 CPL(B) Complement direct word (byte) GPR 2 NEG(B) Negate direct word (byte) GPR 2 AND(B) Bitwise AND, (word/byte operands) 2 / 4 OR(B) Bitwise OR, (word/byte operands) 2 / 4 XOR(B) Bitwise exclusive OR, (word/byte operands) 2 / 4 BCLR/BSET Clear/Set direct bit 2 BMOV(N) Move (negated) direct bit to direct bit 4 BAND/BOR/BXOR AND/OR/XOR dire ct bit with direct bit 4 BCMP Compare direct bit to direct bit 4 BFLDH/BFLDL Bitwise modify masked high/low byte of bit-addressable direct word memory with immediate data CMP(B) Compare word (byte) operands 2 / 4 CMPD1/2 Compare word data to GPR and decrement GPR by 1/2 2 / 4 CMPI1/2 Compare word data to GPR and increment GPR by 1/2 2 / 4 PRIOR Determine number of sh ift cycles to normalize direct word GPR and store result in direct word GPR SHL/SHR Shift left/right direct word GPR 2

XC2000 Family / Compact Line Functional Description Data Sheet 48 V1.2, 2012-07 ROL/ROR Rotate left/right direct word GPR 2 ASHR Arithmetic (sign bit) sh ift right direct word GPR 2 MOV(B) Move word (byte) data 2 / 4 MOVBS/Z Move byte operand to word op. with sign/zero extension 2 / 4 JMPA/I/R Jump absolute/indirect/re lative if condition is met 4 JMPS Jump absolute to a code segment 4 JB(C) Jump relative if direct bit is set (and clear bit) 4 JNB(S) Jump relative if direct bit is not set (and set bit) 4 CALLA/I/R Call absolute/indirect/relativ e subroutine if condition is met 4 CALLS Call absolute subroutine in any code segment 4 PCALL Push direct word register onto system stack and call absolute subroutine TRAP Call interrupt service routine via immediate trap number 2 PUSH/POP Push/pop direct word r egister onto/from system stack 2 SCXT Push direct word register onto system stack and update register with word operand RET(P) Return from intra-segment subroutine (and pop direct word register from system stack) RETS Return from inter-segment subroutine 2 RETI Return from interrupt service subroutine 2 SBRK Software Break 2 SRST Software Reset 4 IDLE Enter Idle Mode 4 PWRDN Unused instruction 1) 4 SRVWDT Service Watchdog Timer 4 DISWDT/ENWDT Disable/Enable Watchdog Timer 4 EINIT End-of-Initialization Register Lock 4 ATOMIC Begin ATOMIC sequence 2 EXTR Begin EXTended Register sequence 2 EXTP(R) Begin EXTended Page (and Register) sequence 2 / 4 EXTS(R) Begin EXTended Segment (and Register) sequence 2 / 4 Table 11 Instruction Set Summary (cont’d) Mnemonic Description Bytes

XC2000 Family / Compact Line Functional Description Data Sheet 49 V1.2, 2012-07 NOP Null operation 2 CoMUL/CoMAC Multiply (and accumulate) 4 CoADD/CoSUB Add/Subtract 4 Co(A)SHR (Arithmetic) Shift right 4 CoSHL Shift left 4 CoLOAD/STORE Load accumulator/Store MAC register 4 CoCMP Compare 4 CoMAX/MIN Maximum/Minimum 4 CoABS/CoRND Absolute value/Round accumulator 4 CoMOV Data move 4 CoNEG/NOP Negate accumulator/Null operation 4 1) The Enter Power Down Mode instruction is not used in the XC2220U, due to the enhanced power control scheme. PWRDN will be correctly decoded, but will trigger no action. Table 11 Instruction Set Summary (cont’d) Mnemonic Description Bytes

XC2000 Family / Compact Line Electrical Parameters Data Sheet 50 V1.2, 2012-07

4 Electrical Parameters

The operating range for the XC2220U is defined by its electrical parameters. For proper operation the specified limits must be respected when integrating the device in its target environment.

4.1 General Parameters

These parameters are valid for all subsequent descriptions, unless otherwise noted. Note: Stresses above the values listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only. Functional operation of the device at these or any other c onditions above those indicated in the operational sections of this specificatio n is not implied. Exposure to absolute maximum rating conditions for an extended time may affect device reliability. During absolute maximum rating overload conditions (VIN > VDDP or VIN < VSS) the voltage on VDDP pins with respect to ground ( VSS) must not exceed the values defined by the absolute maximum ratings. Table 12 Absolute Maximum Rating Parameters Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Output current on a pin when high value is driven IOH SR -15 −− mA Output current on a pin when low value is driven IOL SR −− 15 mA Overload current IOV SR -5 − 5m A 1) 1) Overload condition occurs if the input voltage VIN is out of the absolute maximum rating range. In this case the current must be limited to the listed values by design measures. Absolute sum of overload currents Σ|IOV| SR −− 50 mA 1) Junction Temperature TJ SR -40 − 150 °C Storage Temperature TST SR -65 − 150 °C Digital supply voltage for IO pads and voltage regulators VDDP SR -0.5 − 6.0 V Voltage on any pin with respect to ground (Vss) VIN SR -0.5 − VDDP + 0.5 V VIN≤ VDDP(max)

XC2000 Family / Compact Line Electrical Parameters Data Sheet 51 V1.2, 2012-07

4.1.1 Operating Conditions

The following operating conditions must not be exceeded to ensure correct operation of the XC2220U. All parameters specified in the following sections refer to these operating conditions, unless otherwise noticed. Note: Typical parameter values refer to room temperature and nominal supply voltage, minimum/maximum para meter values also include conditions of minimum/maximum temperature and minimum/maximum supply voltage. Additional details are described where applicable. Table 13 Operating Conditions Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Voltage Regulator Buffer Capacitance for DMP_M CEVRM SR 1.0 − 4.7 μF 1)2) External Load Capacitance CL SR − 203) − pF pin out driver= default System frequency fSYS SR −− 66 MHz 5) Overload current for analog inputs6) IOVA SR -2 − 5 mA not subject to production test Overload current for digital inputs6) IOVD SR -5 − 5 mA not subject to production test Overload current coupling factor for analog inputs7) KOVA CC − 2.5 x 10-4 1.5 x - IOV< 0 mA; not subject to production test − 1.0 x 10-6 1.0 x - IOV> 0 mA; not subject to production test

XC2000 Family / Compact Line Electrical Parameters Data Sheet 52 V1.2, 2012-07 Overload current coupling factor for digital I/O pins KOVD CC − 1.0 x 10-2 3.0 x IOV< 0 mA; not subject to production test − 1.0 x 10-4 5.0 x IOV> 0 mA; not subject to production test Absolute sum of overload currents IOV| SR −− 30 mA not subject to production test Digital core supply voltage for domain M8) VDDIM CC − 1.5 − V Digital supply voltage for IO pads and voltage regulators VDDP SR 3.0 − 5.5 V Digital ground voltage VSS SR − 0 − V 1) To ensure the stability of the voltage regulators the EVRs must be buffered with ceramic capacitors. Separate buffer capacitors with the recomended values sha ll be connected as close as possible to each VDDIM pin to keep the resistance of the board tracks below 2 Ohm. Connect all VDDIM pins together. The minimum capacitance value is required for proper operation under all conditions (e.g. temperature). Higher values slightly increase the startup time. 2) Use one Capacitor for each pin. 3) This is the reference load. For big ger capacitive loads, use the derating factors listed in the PAD properties section. 4) The timing is valid for pin drivers operating in default current mode (selected after reset). Reducing the output current may lead to increased delays or reduced driving capability ( CL). 5) The operating frequency range may be reduced for specific device types. This is indicated in the device 6) Overload conditions occur if the standard operating conditions are exceeded, i.e. the voltage on any pin exceeds the specified range: VOV > VIHmax (IOV > 0) or VOV < VILmin ((IOV < 0). The absolute sum of input overload currents on all pins may not exceed 50 mA. The supply voltages must remain within the specified limits. Proper operation under overload conditions depen ds on the application. Overload conditions must not occur on pin XTAL1. 7) An overload current ( IOV) through a pin injects a certain error current ( IINJ) into the adjacent pins. This error current adds to the respective pins leakage current (IOZ). The amount of error current depends on the overload current and is defined by the overload coupling factor KOV. The polarity of the injected error current is inverse compared to the polarity of the overload current that produces it.The total current through a pin is |ITOT| = |IOZ| + (|IOV| KOV). The additional error current may distort the input voltage on analog inputs. Table 13 Operating Conditions (cont’d) Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max.

XC2000 Family / Compact Line Electrical Parameters Data Sheet 53 V1.2, 2012-07

4.2 Voltage Range definitions

The XC2220U timing depends on the supply vo ltage. If such a dependency exists the timing values are given for 2 voltage ar eas commonly used. T he voltage areas are defined in the following tables.

4.2.1 Parameter Interpretation

The parameters listed in the following incl ude both the characteristics of the XC2220U and its demands on the system. To aid in correctly in terpreting the pa rameters when evaluating them for a design, they are marked accordingly in the column “Symbol”: CC (Controller Characteristics): The logic of the XC2220U provides signals with the specified characteristics. SR (System Requirement): The external system must pr ovide signals with the specif ied characteristics to the XC2220U. 8) Value is controlled by on-chip regulator. Table 14 Upper Voltage Range Definition Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Digital supply voltage for IO pads and voltage regulators VDDP SR 4.5 5.0 5.5 V Table 15 Lower Voltage Range Definition Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Digital supply voltage for IO pads and voltage regulators VDDP SR 3.0 3.3 4.5 V

XC2000 Family / Compact Line Electrical Parameters Data Sheet 54 V1.2, 2012-07

4.3 DC Parameters

These parameters are static or average values that may be exceeded during switching transitions (e.g. output current). The XC2220U can operate within a wide suppl y voltage range from 3.0 V to 5.5 V. However, during operation this supply volt age must remain within 10 percent of the selected nominal supply voltage. It cannot vary across the full operating voltage range. Because of the supply voltage restrictio n and because electrical behavior depends on the supply voltage, the parameters are specified separately for the upper and the lower voltage range. During operation, the supply voltages may only change with a maximum speed of dV/dt < 1 V/ms. Leakage current is strongly dependent on t he operating temperature and the voltage level at the respective pin. The maximum values in the following tables apply under worst case conditions, i.e. maximum temperature and an input level equal to the supply voltage. The value for the leakage current in an a pplication can be determined by using the respective leakage derating formula (see tables) with values from that application. The pads of the XC2220U are designed to operate in various driver modes. The DC parameter specifications refer to the pad current limits specified in Section 4.7.4.

XC2000 Family / Compact Line Electrical Parameters Data Sheet 55 V1.2, 2012-07 Pullup/Pulldown Device Behavior Most pins of the XC2220U f eature pullup or pulldown devices. For some special pins these are fixed; for the port pins they can be selected by the application. The specified current values indicate how to load the respective pin depending on the intended signal level. Figure 11 shows the current paths. The shaded resistors shown in the figure may be required to compensate system pull currents that do not match the given limit values. Figure 11 Pullup/Pulldown Current Definition MC _XC2X_ PULL VDDP VSS Pullup Pulldown

XC2000 Family / Compact Line Electrical Parameters Data Sheet 56 V1.2, 2012-07

4.3.1 DC Parameters for Upper Voltage Area

Keeping signal levels within the limits spec ified in this table ensures operation without overload conditions. For signal levels outside these specifications, also refer to the specification of the overload current IOV. Note: Operating Conditions apply. Table 16 is valid under the following conditions: VDDP≤ 5.5 V; VDDPtyp. 5 V; VDDP≥ 4.5 V Table 16 DC Characteristics for Upper Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Pin capacitance (digital inputs/outputs). CIO CC −− 10 pF not subject to production test Input Hysteresis1) HYS CC 0.11 x VDDP −− V RS=0O h m Absolute input leakage current on pins of analog ports2) |IOZ1| CC − 10 200 nA VIN> VSS ; VIN< VDDP Absolute input leakage current for all other pins. 2)3) |IOZ2| CC − 0.2 5 μA TJ≤ 110 °C; VIN> VSS ; VIN< VDDP − 0.2 10 μA TJ≤ 150 °C; VIN> VSS ; VIN< VDDP Pull Level Force Current4) |IPLF| SR 220 −−μ A VIN≥ VIHmin (pulldown_ena bled); VIN≤ VILmax (pullup_enable Pull Level Keep Current5) |IPLK| SR −− 30 μA VIN≥ VIHmin (pullup_enable d); VIN≤ VILmax (pulldown_ena bled) Input high voltage (all except XTAL1) VIH SR 0.7 x VDDP − VDDP + 0.3 V

XC2000 Family / Compact Line Electrical Parameters Data Sheet 57 V1.2, 2012-07 Input low voltage (all except XTAL1) VIL SR -0.3 − 0.3 x VDDP V Output High voltage6) VOH CC VDDP - 1.0 −− V IOH≥ IOHmax VDDP - 0.4 −− V IOH≥ IOHnom Output Low Voltage6) VOL CC −− 0.4 V IOL≤ IOLnom −− 1.0 V IOL≤ IOLmax 1) Not subject to production test - ve rified by design/characterization. H ysteresis is implemented to avoid metastable states and switching due to internal ground bounce. It cannot suppress switching due to external system noise under all conditions. 2) If the input voltage exceeds the respecti ve supply voltage due to ground bouncing ( VIN < VSS) or supply ripple (VIN > VDDP), a certain amount of current may flow through the protection diodes. This current adds to the leakage current. An additional error current (IINJ) will flow if an overload current flows through an adjacent pin. Please refer to the definition of the overload coupling factor KOV. 3) The given values are worst-case val ues. In production test, this leakage current is only tested at 125 °C; other values are ensured by correlation. For derating, plea se refer to the following descriptions: Leakage derating depending on temperature (TJ = junction temperature [°C]): IOZ = 0.05 x e(1.5 + 0.028 x TJ>) [μA]. For example, at a temperature of 95 °C the resulting leakage current is 3.2 μA. Leakage derating depending on voltage level (DV = VDDP - VPIN [V]): IOZ = IOZtempmax - (1.6 x DV) ( μA]. This voltage derating formula is an approximation which applies for maximum temperature. 4) Drive the indicated minimum current through this pin to change the default pin level driven by the enabled pull device. 5) Limit the current through this pin to the indicated value so that the enabled pull device can keep the default pin level. 6) The maximum deliverable output current of a port driv er depends on the selected output driver mode. This specification is not valid for outputs which are switched to open drain mode. In this case the respective output will float and the voltage is determined by the external circuit. 7) As a rule, with decreasing output current the output levels approach the respective supply level (VOL->VSS, VOH->VDDP). However, only the levels for nominal output currents are verified. 8) As a rule, with decreasing output current the out put levels approach the respective supply level ( VOL->VSS, VOH->VDDP). However, only the levels for nominal output currents are verified. Table 16 DC Characteristics for Upper Voltage Range (cont’d) Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max.

XC2000 Family / Compact Line Electrical Parameters Data Sheet 58 V1.2, 2012-07

4.3.2 DC Parameters for Lower Voltage Area

Keeping signal levels within the limits spec ified in this table ensures operation without overload conditions. For signal levels outside these specifications, also refer to the specification of the overload current IOV. Note: Operating Conditions apply. Table 17 is valid under the following conditions: VDDP≥ 3.0 V; VDDPtyp. 3.3 V; VDDP≤ 4.5 V Table 17 DC Characteristics for Lower Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Pin capacitance (digital inputs/outputs). CIO CC −− 10 pF not subject to production test Input Hysteresis1) HYS CC 0.07 x VDDP −− V RS=0O h m Absolute input leakage current on pins of analog ports2) |IOZ1| CC − 10 200 nA VIN> VSS ; VIN< VDDP Absolute input leakage current for all other pins. 2)3) |IOZ2| CC − 0.2 2 μA TJ≤ 110 °C; VIN> VSS ; VIN< VDDP − 0.2 6 μA TJ≤ 150 °C; VIN> VSS ; VIN< VDDP Pull Level Force Current4) |IPLF| SR 150 −−μ A VIN≥ VIHmin (pulldown_ena bled); VIN≤ VILmax (pullup_enable Pull Level Keep Current5) |IPLK| SR −− 10 μA VIN≥ VIHmin (pullup_enable d); VIN≤ VILmax (pulldown_ena bled)

XC2000 Family / Compact Line Electrical Parameters Data Sheet 59 V1.2, 2012-07 Input high voltage (all except XTAL1) VIH SR 0.7 x VDDP − VDDP + 0.3 V Input low voltage (all except XTAL1) VIL SR -0.3 − 0.3 x VDDP V Output High voltage6) VOH CC VDDP - 1.0 −− V IOH≥ IOHmax VDDP - 0.4 −− V IOH≥ IOHnom Output Low Voltage6) VOL CC −− 0.4 V IOL≤ IOLnom −− 1.0 V IOL≤ IOLmax 1) Not subject to production test - ve rified by design/characterization. H ysteresis is implemented to avoid metastable states and switching due to internal ground bounce. It cannot suppress switching due to external system noise under all conditions. 2) If the input voltage exceeds the respecti ve supply voltage due to ground bouncing ( VIN < VSS) or supply ripple (VIN > VDDP), a certain amount of current may flow through the protection diodes. This current adds to the leakage current. An additional error current (IINJ) will flow if an overload current flows through an adjacent pin. Please refer to the definition of the overload coupling factor KOV. 3) The given values are worst-case val ues. In production test, this leakage current is only tested at 125 °C; other values are ensured by correlation. For derating, plea se refer to the following descriptions: Leakage derating depending on temperature (TJ = junction temperature [°C]): IOZ = 0.05 x e(1.5 + 0.028 x TJ>) [μA]. For example, at a temperature of 95 °C the resulting leakage current is 3.2 μA. Leakage derating depending on voltage level (DV = VDDP - VPIN [V]): IOZ = IOZtempmax - (1.6 x DV) ( μA]. This voltage derating formula is an approximation which applies for maximum temperature. 4) Drive the indicated minimum current through this pin to change the default pin level driven by the enabled pull device. 5) Limit the current through this pin to the indicated value so that the enabled pull device can keep the default pin level. 6) The maximum deliverable output current of a port driv er depends on the selected output driver mode. This specification is not valid for outputs which are switched to open drain mode. In this case the respective output will float and the voltage is determined by the external circuit. 7) As a rule, with decreasing output current the output levels approach the respective supply level (VOL->VSS, VOH->VDDP). However, only the levels for nominal output currents are verified. 8) As a rule, with decreasing output current the out put levels approach the respective supply level ( VOL->VSS, VOH->VDDP). However, only the levels for nominal output currents are verified. Table 17 DC Characteristics for Lower Voltage Range (cont’d) Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max.

XC2000 Family / Compact Line Electrical Parameters Data Sheet 60 V1.2, 2012-07

4.3.3 Power Consumption

The power consumed by the XC2220U depends on several factors such as supply voltage, operating frequency, active circuits, and operating temperature. The power consumption specified here consists of two components:

  • The switching current IS depends on the device activity
  • The leakage current ILK depends on the device temperature To determine the actual power consumption, always both components, switching current IS and leakage current ILK must be added: IDDP = IS + ILK. Note: The power consumption values are not subject to production test. They are verified by design/characterization. To determine the total power consumpti on for dimensioning the external power supply, also the pad driver currents must be considered. The given power consumption parameters and their values refer to specific operating conditions:
  • Active mode: Regular operation, i.e. peripherals are active, code execution out of Flash.
  • Stopover mode: Crystal oscillator and PLL stopped, Flash switched off, clock in most parts of domain DMP_M stopped. Note: The maximum values cover the comp lete specified operating range of all manufactured devices. The typical values refer to average devices under typical conditions, such as nominal supply voltage, room temperature, application-oriented activity. After a power reset, the decoupling capacitors for VDDIM are charged with the maximum possible current. For additional information, please refer to Section 5.2, Thermal Considerations. Note: Operating Conditions apply.

XC2000 Family / Compact Line Electrical Parameters Data Sheet 61 V1.2, 2012-07 Active Mode Power Supply Current The actual power supply current in active mode not only depends on the system frequency but also on the configuration of the XC2220U’s subsystem. Besides the power consumed by the device logic the power supply pins also provide the current that flows through the pin output drivers. A small current is consumed because the drivers’ input stages are switched. Table 18 Switching Power Consumption Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Power supply current (active) with all peripherals active and EVVRs on ISACT CC − 5.5 + 0.4 x fSYS 1) fSYS in MHz 7 + 0.6 x fSYS mA power_mode= active ; voltage_range= both 2)3)4) 2) The pad supply voltage pins ( VDDPB) provide the input current for the on-chip EVVRs and the current consumed by the pin output drivers. A small current is consumed because t he drivers input stages are switched. 3) Please consider the additional conditions described in section "Active Mode Power Supply Current". 4) The pad supply voltage only has a minor influence on this parameter. Power supply current in stopover mode, EVVRs on ISSO CC − 0.7 2.0 mA power_mode= stopover ; voltage_range= both

XC2000 Family / Compact Line Electrical Parameters Data Sheet 62 V1.2, 2012-07 Figure 12 Supply Current in Active Mode as a Function of Frequency Note: Operating Conditions apply. Leakage Power Consumption Calculation The leakage power consumption can be calculated according to the following formulas: Table 19 Leakage Power Consumption Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Leakage supply current1)2) 1) The supply current caused by leak age depends mainly on the junction temperature and the supply voltage. The temperature difference between the junction temperature TJ and the ambient temperature TA must be taken into account. As this fraction of the supply current does not depend on device activity, it must be added to other power consumption values. 2) All inputs (including pins configured as inputs) are set at 0 V to 0.1 V or at VDDP - 0.1 V to VDDP and all outputs (including pins configured as outputs) are disconnected. ILK1 CC − 0.03 0.04 mA TJ=2 5° C − 0.4 0.95 mA TJ=8 5° C − 1.5 4.6 mA TJ=1 2 5° C − 3.3 10.1 mA TJ=1 5 0° C MC_XC2XU_IS fSYS [MHz] 20 40 80 60 ISACTtyp ISACTmax IS [mA]

XC2000 Family / Compact Line Electrical Parameters Data Sheet 63 V1.2, 2012-07 ILK1 = 440,000 + e-α with α = 5000 / (273 + B×TJ) Parameter B must be replaced by

  • 1.0 for typical values
  • 1.3 for maximum values Figure 13 Leakage Supply Current as a Function of Temperature MC_XC2XU_ILKN TJ [°C] ILK [mA] 05 0 1 5 0 100-50

12 ILK1max

XC2000 Family / Compact Line Electrical Parameters Data Sheet 64 V1.2, 2012-07

4.4 Analog/Digital Converter Parameters

These parameters describe the conditions for optimum ADC performance. Note: Operating Conditions apply. Table 20 ADC Parameters for All Voltage Ranges Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Switched capacitance at an analog input CAINSW CC − 9 20 pF not subject to production test 1) These parameter values cover the complete operating range. Under relaxed operating conditions (temperature, supply voltage) typical values can be used for calculation. Total capacitance at an analog input CAINT CC − 20 30 pF not subject to production test Switched capacitance at the reference input CAREFSW CC − 15 30 pF not subject to production test Total capacitance at the reference input CAREFT CC − 20 40 pF not subject to production test Broken wire detection delay against VAGND2) tBWG CC −− 503) Broken wire detection delay against VAREF2) tBWR CC −− 504) Conversion time for 8-bit result2) tc8 CC (10 + STC x tADCI + 2 x tSYS Conversion time for 10-bit result tc10 CC (12 + STC x tADCI + 2 x tSYS Conversion time for 12-bit result tc12 CC (16 + STC x tADCI + 2 x tSYS Analog reference ground VAGND SR VSS - 0.05 − 1.5 V Analog input voltage range VAIN SR VAGND − VAREF V 5) Analog reference voltage VAREF SR VAGND + 1.0 − VDDPB + 0.05 V

XC2000 Family / Compact Line Electrical Parameters Data Sheet 65 V1.2, 2012-07 2) This parameter includes the sample time (also the a dditional sample time specified by STC), the time to determine the digital result and the time to load the result register with the conversion result. Values for the basic clock tADCI depend on programming. 3) The broken wire detection delay against VAGND is measured in numbers of consecutive precharge cycles at a conversion rate of not more than 500 µs. Result below 10% (66H) 4) The broken wire detection delay against VAREF is measured in numbers of consecutive precharge cycles at a conversion rate of not more than 10 µs. This function is influenced by leakage current, in particular at high temperature. Result above 80% (332H) 5) VAIN may exceed VAGND or VAREF up to the absolute maximum ratings. However, the conversion result in these cases will be X000H or X3FFH, respectively. Table 21 ADC Parameters for Upper Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Input resistance of the selected analog channel RAIN CC − 0.9 1.5 kOh m not subject to production test Input resistance of the reference input RAREF CC − 0.5 1 kOh m not subject to production test Differential Non-Linearity Error2)3)4)5) |EADNL| CC − 2.5 5.0 LSB Gain Error2)3)4)5) |EAGAIN| CC − 2.5 6.0 LSB Integral Non- Linearity2)3)4)5) |EAINL| CC − 2.0 4.0 LSB Offset Error2)3)4)5) |EAOFF| CC − 2.0 4.0 LSB Analog clock frequency fADCI SR 2 − 20 MHz Std. reference input (VAREF) 2 − 17.5 MHz Alt. reference input (CH0) Total Unadjusted Error3)4) |TUE| CC − 2.5 5.5 LSB 6)7) Wakeup time from analog powerdown, fast mode tWAF CC −− 7.0 μs Wakeup time from analog powerdown, slow mode tWAS CC −− 11.5 μs

XC2000 Family / Compact Line Electrical Parameters Data Sheet 66 V1.2, 2012-07 1) These parameter values cover the complete operating range. Under relaxed operating conditions (temperature, supply voltage) typical values can be used for calculation. 2) The sum of DNL/INL/GAIN/OFF errors does not exceed the related TUE total unadjusted error. 3) If a reduced analog reference voltage between 1V and VDDPB / 2 is used, then there are additional decrease in the ADC speed and accuracy. 4) If the analog reference voltage range is below VDDPB but still in the defined range of VDDPB / 2 and VDDPB is used, then the ADC converter errors increase. If the re ference voltage is reduced by the factor k (k<1), TUE, DNL, INL, Gain and Offset errors increase also by the factor 1/k. 5) If the analog reference voltage is > VDDPB, then the ADC converter errors increase. 6) TUE is based on 12-bit conversion. 7) TUE is tested at VAREF = VDDPB = 5.0 V, VAGND = 0 V. It is verified by design for all other voltages within the defined voltage range. The specified TUE is valid only if the absolute sum of input overload currents on analog port pins (see IOV specification) does not exceed 10 mA, and if VAREF and VAGND remain stable during the measurement time. Table 22 ADC Parameters for Lower Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Input resistance of the selected analog channel RAIN CC − 1.4 2.5 kOh m not subject to production test Input resistance of the reference input RAREF CC − 1.0 2.0 kOh m not subject to production test Differential Non-Linearity Error 2)3)4)5) |EADNL| CC − 2.5 5.5 LSB Gain Error2)3)4)5) |EAGAIN| CC − 3.0 8.0 LSB Integral Non- Linearity2)3)4)5) |EAINL| CC − 2.5 7.5 LSB Offset Error2)3)4)5) |EAOFF| CC − 2.0 5.5 LSB Analog clock frequency fADCI SR 2 − 16.7 MHz Std. reference input (VAREF) 2 − 12.1 MHz Alt. reference input (CH0) Total Unadjusted Error3)4) |TUE| CC − 2.5 7.5 LSB 6)7)

XC2000 Family / Compact Line Electrical Parameters Data Sheet 67 V1.2, 2012-07 Figure 14 Equivalent Circuitry for Analog Inputs Sample time and conversion time of the XC2220U’s A/D converters are programmable. The timing above can be calculated using Table 23. The limit values for fADCI must not be exceeded when selecting the prescaler value. Wakeup time from analog powerdown, fast mode tWAF CC −− 8.5 μs Wakeup time from analog powerdown, slow mode tWAS CC −− 15.0 μs 1) These parameter values cover the complete operating range. Under relaxed operating conditions (temperature, supply voltage) typical values can be used for calculation. 2) The sum of DNL/INL/GAIN/OFF errors does not exceed the related TUE total unadjusted error. 3) If a reduced analog reference voltage between 1V and VDDPB / 2 is used, then there are additional decrease in the ADC speed and accuracy. 4) If the analog reference voltage range is below VDDPB but still in the defined range of VDDPB / 2 and VDDPB is used, then the ADC converter errors increase. If the re ference voltage is reduced by the factor k (k<1), TUE, DNL, INL, Gain and Offset errors increase also by the factor 1/k. 5) If the analog reference voltage is > VDDPB, then the ADC converter errors increase. 6) TUE is based on 12-bit conversion. 7) TUE is tested at VAREF = VDDPB = 3.3 V, VAGND = 0 V. It is verified by design for all other voltages within the defined voltage range. The specified TUE is valid only if the absolute sum of input overload currents on analog port pins (see IOV specification) does not exceed 10 mA, and if VAREF and VAGND remain stable during the measurement time. Table 22 ADC Parameters for Lower Voltage Range (cont’d) Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. A/D Converter MCS05570 RSource VAIN CExt CAINT CAINS- RAIN, On CAINS

XC2000 Family / Compact Line Electrical Parameters Data Sheet 68 V1.2, 2012-07 Converter Timing Example A: Converter Timing Example B: Table 23 A/D Converter Computation Table GLOBCTR.5-0 (DIVA) A/D Converter Analog Clock fADCI INPCRx.7-0 (STC) Sample Time tS 1) The selected sample time is doubled if broken wire detection is active (due to the presampling phase). 000000B fSYS 00H tADCI × 2 000001B fSYS / 2 01 H tADCI × 3 000010B fSYS / 3 02 H tADCI × 4 : fSYS / (DIVA+1) : tADCI × (STC+2) 111110B fSYS / 63 FE H tADCI × 256 111111B fSYS / 64 FF H tADCI × 257 Assumptions: fSYS = 66 MHz (i.e. tSYS = 15.2 ns), DIVA = 03H, STC = 00H Analog clock fADCI = fSYS / 4 = 16.5 MHz, i.e. tADCI = 60.6 ns Sample time tS = tADCI × 2 = 121.2 ns Conversion 12-bit: tC12 = 16 × tADCI + 2 × tSYS = 16 × 60.6 ns + 2 × 15.2 ns = 1.0 μs Conversion 10-bit: tC10 = 12 × tADCI + 2 × tSYS = 12 × 60.6 ns + 2 × 15.2 ns = 0.758 μs Conversion 8-bit: tC8 = 10 × tADCI + 2 × tSYS = 10 × 60.6 ns + 2 × 15.2 ns = 0.636 μs Assumptions: fSYS = 40 MHz (i.e. tSYS = 25 ns), DIVA = 01H, STC = 00H Analog clock fADCI = fSYS / 2 = 20 MHz, i.e. tADCI = 50 ns Sample time tS = tADCI × 2 = 100 ns Conversion 12-bit: tC12 = 16 × tADCI + 2 × tSYS = 16 × 50 ns + 2 × 25 ns = 0.85 μs Conversion 10-bit: tC10 = 12 × tADCI + 2 × tSYS = 12 × 50 ns + 2 × 25 ns = 0.65 μs

XC2000 Family / Compact Line Electrical Parameters Data Sheet 69 V1.2, 2012-07 Conversion 8-bit: tC8 = 10 × tADCI + 2 × tSYS = 10 × 50 ns + 2 × 25 ns = 0.55 μs

XC2000 Family / Compact Line Electrical Parameters Data Sheet 70 V1.2, 2012-07

4.5 System Parameters

The following parameters specify several aspects which are important when integrating the XC2220U into an application system. Note: These parameters are not subject to production test but verified by design and/or characterization. Note: Operating Conditions apply. Table 24 Various System Parameters Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Short-term deviation of internal clock source frequency1) 1) The short-term frequency deviation refe rs to a timeframe of a few hours and is measured relative to the current frequency at the beginning of the respective timeframe. This parameter is useful to determine a time span for re-triggering a LIN synchronization. ΔfINT CC -1 − 1% ΔTJ = ≤ 10°C Internal clock source frequency fINT CC 4.8 5.0 5.2 MHz Wakeup clock source frequency2) 2) This parameter is tested for the fastest and the slowes t selection. The medium selections are not subject to production test - verified by design/characterization. fWU CC 400 − 700 kHz FREQSEL= 00 210 − 390 kHz FREQSEL= 01 140 − 260 kHz FREQSEL= 10 110 − 200 kHz FREQSEL= 11 Startup time from power- on with code execution from Flash tSPO CC 1.4 1.9 2.4 ms fWU = 500 kHz Startup time from stopover mode with code execution from PSRAM tSSO CC 11 / fWU 3) fWU in MHz. − 12 / fWU μs Core voltage (PVC) supervision level VPVC CC VLV - 0.03 VLV VLV + 0.074) V 5) Supply watchdog (SWD) supervision level VSWD CC VLV - 0.106) VLV VLV + 0.15 V voltage_range= lower 5) VLV - 0.15 VLV VLV + 0.15 V voltage_range= upper 5)

XC2000 Family / Compact Line Electrical Parameters Data Sheet 71 V1.2, 2012-07 Conditions for tSPO Timing Measurement The time required for the transition from Power-On to Base mode is called tSPO. It is measured under the following conditions: Precondition: The pad supply is valid, i.e. VDDPB is above 3.0 V and remains above 3.0 V even though the XC2220U is starting up. No debugger is attached. Start condition: Power on reset is removed (PORST = 1). End condition: External pin toggle caused by first user instruction executed from Flash after startup. Conditions for tSSO Timing Measurement The time required for the transition from Stopover to Stopover Waked-Up mode is called tSSO. It is measured under the following conditions: Precondition: The Stopover mode has been entered using the procedure defined in the Programmer’s Guide. Start condition: Pin toggle on ESR pin triggering the startup sequence. End condition: External pin toggle caused by first user instruction executed from PSRAM after startup. 4) This value includes a hysteresis of approximately 50 mV for rising voltage. 5) VLV = selected SWD voltage level 6) The limit VLV - 0.10 V is valid for the OK1 level. The limit for the OK2 level is VLV - 0.15 V.

XC2000 Family / Compact Line Electrical Parameters Data Sheet 72 V1.2, 2012-07 Coding of bit fields LEVxV in SWD Configuration Registers After power-on the supply watch dog is precon figured to operate in the lower voltage range. Coding of bit fields LEVxV in PVC Configuration Registers The core voltages are controlled internally to the nominal value of 1.5 V; a variation of ±10 % is allowed. These operation conditions limit the possible PVC monitoring values to the predefined reset values shown in Table 26. Table 25 Coding of bit fields LEVxV in Register SWDCON0 Code Default Voltage Level Notes 1) 1) The indicated default levels are selected automatically after a power reset. 0000B - out of valid operation range 0001B 3.0 V LEV1V: reset request 0010B - 0101B 3.1 V - 3.4 V step width is 0.1 V 0110B 3.6 V 0111B 4.0 V 1000B 4.2 V 1001B 4.5 V LEV2V: no request 1010B - 1110B 4.6 V - 5.0 V step width is 0.1 V 1111B 5.5 V Table 26 Coding of bit fields LEVxV in Registers PVCyCONz Code Default Voltage Level Notes 1) 1) The indicated default levels are selected automatically after a power reset. 000B - 011B - out of valid operation range 100B 1.35 V LEV1V: reset request 101B 1.45 V LEV2V: interrupt request 2) 2) Due to variations of the tolerance of both the Embedded Voltage Regulators (EVR) and PVC levels, this interrupt can be triggered inadvertently, even though the core voltage is within the normal range. It is, therefore, recommended not to use this warning level. 110B - 111B - out of valid operation range

XC2000 Family / Compact Line Electrical Parameters Data Sheet 73 V1.2, 2012-07

4.6 Flash Memory Parameters

The XC2220U is delivered with all Flash sectors erased and with no protection installed. The data retention time of the XC2220U’s Flash memory (i.e. the time after which stored data can still be retrieved) depends on the number of times the Flash memory has been erased and programmed. Note: These parameters are not subject to production test but verified by design and/or characterization. Note: Operating Conditions apply. Table 27 Flash Parameters Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Parallel Flash module program/erase limit depending on Flash read activity NPP SR −− 11) NFL_RD≤ 1 Flash erase endurance for security pages NSEC SR 10 −− cycle s tRET≥ 20 years Flash wait states2) NWSFLASH SR 1 −− fSYS≤ 8M H z 2 −− fSYS≤ 13 MHz 3 −− fSYS≤ 17 MHz 4 −− fSYS>1 7M H z Erase time per sector/page tER CC − 73) 8.0 ms Programming time per page tPR CC − 33) 3.5 ms Data retention time tRET CC 20 −− year s NER≤ 1,000 cycl es Drain disturb limit NDD SR 32 −− cycle s

XC2000 Family / Compact Line Electrical Parameters Data Sheet 74 V1.2, 2012-07 Access to the XC2220U Flash modules is co ntrolled by the IMB. Built-in prefetch mechanisms optimize the performance for sequential access. Flash access waitstates only affect non-sequential access. Due to prefetch mechanisms, the performance for sequential access (depending on the software structure) is only partially influenced by waitstates. Number of erase cycles NER SR −− 15000 cycle s tRET≥ 5 years; Valid for up to 64 user selected sectors (data storage) −− 1000 cycle s tRET≥ 20 years 1) All Flash module(s) can be erased/programmed while code is executed and/or data is read from only one Flash module or from PSRAM. The Flash module that delivers code/data can, of course, not be erased/programmed. 2) Value of IMB_IMBCTRL.WSFLASH. 3) Programming and erase times depend on the internal Flash clock source. The control state machine needs a few system clock cycles. This increases the stated du rations noticably only at extremely low system clock frequencies. Table 27 Flash Parameters (cont’d) Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max.

XC2000 Family / Compact Line Electrical Parameters Data Sheet 75 V1.2, 2012-07

4.7 AC Parameters

These parameters describe the dynamic behavior of the XC2220U.

4.7.1 Testing Waveforms

These values are used for characterization and production testing (except pin XTAL1). Figure 15 Input Output Waveforms Figure 16 Floating Waveforms MCD05556C

0.3 VDDP

(driven by tester) Output Signal (measured) Hold time Output delay Output delay Hold time Output timings refer to the rising edge of CLKOUT. Input timings are calculated from the time, when the input signal reaches VIH or VIL, respectively.

0.2 VDDP

0.8 VDDP

0.7 VDDP

VLoad + 0.1 V VLoad - 0.1 V VOH - 0.1 V VOL + 0.1 V For timing purposes a port pin is no longer floating when a 100 mV change from load voltage occurs, but begins to float when a 100 mV change from the loaded VOH /VOL level occurs ( IOH / IOL = 20 mA).

XC2000 Family / Compact Line Electrical Parameters Data Sheet 76 V1.2, 2012-07

4.7.2 Definition of Internal Timing

The internal operation of the XC2220U is controlled by the internal system clock fSYS. Because the system clock signal fSYS can be generated from a number of internal and external sources using different mechanism s, the duration of the system clock periods (TCSs) and their variation (as well as th e derived external timing) depend on the mechanism used to generate fSYS. This must be considered when calculating the timing for the XC2220U. Figure 17 Generation Mechanisms for the System Clock Note: The example of PLL operation shown in Figure 17 uses a PLL factor of 1:4; the example of prescaler operation uses a divider factor of 2:1. The specification of the external timing (AC Characteristics) depends on the period of the system clock (TCS). M C_XC2X_CLOCKGEN Phase Locked Loop Operation (1:N) fIN Direct Clock Drive (1:1) Prescaler Operation (N:1) fSYS fIN fSYS fIN fSYS TCS TCS TCS

XC2000 Family / Compact Line Electrical Parameters Data Sheet 77 V1.2, 2012-07 Direct Drive When direct drive operation is selected (SYSCON0.CLKSEL = 11B), the system clock is derived directly from the input clock signal CLKIN1: fSYS = fIN. The frequency of fSYS is the same as the frequency of fIN. In this case the high and low times of fSYS are determined by the duty cycle of the input clock fIN. Selecting Bypass Operation from the XTAL11) input and using a divider factor of 1 results in a similar configuration. Prescaler Operation When prescaler operation is selected (SYSCON0.CLKSEL = 10B, PLLCON0.VCOBY = 1B), the system clock is derived either from the crystal oscillat or (input clock signal XTAL1) or from the internal clock source through the output prescaler K1 (= K1DIV+1): fSYS = fOSC / K1. If a divider factor of 1 is selected, the frequency of fSYS equals the frequency of fOSC. In this case the high and low times of fSYS are determined by the duty cycle of the input clock fOSC (external or internal). The lowest system clock fr equency results from selecting the maximum value for the divider factor K1: fSYS = fOSC / 1024.

4.7.2.1 Phase Locked Loop (PLL)

When PLL operation is sele cted (SYSCON0.CLKSEL = 10B, PLLCON0.VCOBY = 0B), the on-chip phase locked loop is enabled and provides the system clock. The PLL multiplies the input frequency by the factor F (fSYS = fIN × F). F is calculated from the input divider P (= PDIV+1), the multiplication factor N (= NDIV+1), and the output divider K2 (= K2DIV+1): The input clock can be derived either from an external source at XTAL1 or from the on- chip clock source. The PLL circuit synchronizes the system clock to the input clock. This synchronization is performed smoothly so that the system clock frequency does not change abruptly. Adjustment to the input clock continuously changes the frequency of fSYS so that it is locked to fIN. The slight variation causes a jitter of fSYS which in turn affects the duration of individual TCSs. 1) Voltages on XTAL1 must comply to the core supply voltage VDDIM.

XC2000 Family / Compact Line Electrical Parameters Data Sheet 78 V1.2, 2012-07 The timing in the AC Characteristics refers to TCSs. Timing must be calculated using the minimum TCS possible under the given circumstances. The actual minimum value for TCS depends on the jitter of the PLL. Because the PLL is constantly adjusting its output frequency to correspond to the input frequency (from crystal or oscillator), the accumulated jitte r is limited. This means that the relative deviation for periods of more than one TCS is lower than for a single TCS (see formulas and Figure 18). This is especially important for bus cycles using waitstates and for the operation of timers, serial interfaces, etc. For all slower operations and longer periods (e.g. pulse train generation or measurement, lower baudrates, etc.) the deviation caused by the PLL jitter is negligible. The value of the accumulated PLL jitter depends on the number of consecutive VCO output cycles within the respec tive timeframe. The VCO outp ut clock is divided by the output prescaler K2 to generate the system clock signal fSYS. The number of VCO cycles is K2 × T, where T is the number of consecutive fSYS cycles (TCS). The maximum accumulated jitter (long-term jitter) DTmax is defined by: DTmax [ns] = ±(220 / (K2 × fSYS) + 4.3) This maximum value is applicable, if either the number of clock cycles T > (fSYS / 1.2) or the prescaler value K2 > 17. In all other cases for a timeframe of T × TCS the accumulated jitter DT is determined by: fSYS in [MHz] in all formulas. Example, for a period of 3 TCSs @ 33 MHz and K2 = 4: D max = ±(220 / (4 × 33) + 4.3) = 5.97 ns (Not applicable directly in this case!) = 1.7 ns Example, for a period of 3 TCSs @ 33 MHz and K2 = 2: Dmax = ±(220 / (2 × 33) + 4.3) = 7.63 ns (Not applicable directly in this case!) = 1.4 ns

XC2000 Family / Compact Line Electrical Parameters Data Sheet 79 V1.2, 2012-07 Figure 18 Approximated Accumulated PLL Jitter Note: The specified PLL jitter values are va lid if the capacitive load per pin does not exceed CL =2 0p F . The maximum peak-to-peak noise on the pad supply voltage (measured between VDDPB pin and VSS pin) is limited to a peak-to-peak voltage of VPP = 50 mV. This can be achieved by appropriate blocking of the supply voltage as close as possible to the supply pins and using PCB supply and ground planes. PLL frequency band selection Different frequency bands can be selected for the VCO so that the operation of the PLL can be adjusted to a wide range of input and output frequencies: MC_ XC2 X_JITTER Cycles T0 Acc. jitter DT 20 40 60 80 100 ns fSYS = 66 MHz fVCO = 132 MHz fVCO = 66 MHz ±9 fSYS = 33 MHz

XC2000 Family / Compact Line Electrical Parameters Data Sheet 80 V1.2, 2012-07

4.7.2.2 Wakeup Clock

When wakeup operation is selected (SYSCON0.CLKSEL = 00 B), the system clock is derived from the low-frequency wakeup clock source: fSYS = fWU. In this mode, a basic functionality can be maintained without requiring an external clock source and while minimizing the power consumption.

4.7.2.3 Selecting and Changing the Operating Frequency

When selecting a clock source and the clock generation method, the required parameters must be carefully written to t he respective bit fields, to avoid unintended intermediate states. Many applications change the fr equency of the system clock ( fSYS) during operation in order to optimize system performance and power consumption. Changing the operating frequency also changes the switching currents, which influences the power supply. To ensure proper operation of the on-chip EVRs while they generate the core voltage, the operating frequency shall only be changed in certain steps. This prevents overshoots and undershoots of the supply voltage. To avoid the indicated problems, recommended sequences are provided which ensure the intended operation of the clock system interacting with the power system. Please refer to the Programmer’s Guide. Table 28 System PLL Parameters Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. VCO output frequency fVCO CC 50 − 110 MHz VCOSEL=0 0B; VCOmode= controlled 10 − 40 MHz VCOSEL=0 0B; VCOmode=f r e e running 100 − 160 MHz VCOSEL=0 1B; VCOmode= controlled 20 − 80 MHz VCOSEL=0 1B; VCOmode=f r e e running

XC2000 Family / Compact Line Electrical Parameters Data Sheet 81 V1.2, 2012-07

4.7.3 External Clock Input Parameters

These parameters specify the external clock generation for the XC2220U. The clock can be generated in two ways:

  • By connecting a crystal or ceramic resonator to pins XTAL1/XTAL2.
  • By supplying an external clock signal. This clock signal can be supplied either to pin XTAL1 (core voltage domain) or to pin CLKIN1 (IO voltage domain). If connected to CLKIN1, the input signal must reach the defined input levels VIL and VIH. If connected to XTAL1, a minimum amplitude VAX1 (peak-to-peak voltage) is sufficient for the operation of the on-chip oscillator. Note: The given clock timing parameters ( t1 … t4) are only valid for an external clock input signal. Note: Operating Conditions apply. Table 29 External Clock Input Characteristics Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Oscillator frequency fOSC SR 4 − 40 MHz Input= Clock Signal 4 − 16 MHz Input= Crystal or Resonator XTAL1 input current absolute value |IIL| CC −− 20 μA Input clock high time t1 SR 6 −− ns Input clock low time t2 SR 6 −− ns Input clock rise time t3 SR − 88n s Input clock fall time t4 SR − 88n s Input voltage amplitude on XTAL11) 1) The amplitude voltage VAX1 refers to the offset voltage VOFF. This offset voltage must be stable during the operation and the resulting voltage peaks must remain within the limits defined by VIX1. VAX1 SR 0.3 x VDDIM −− V fOSC≥ 4M H z ; fOSC≤ 16 MHz 0.4 x VDDIM −− V fOSC≥ 16 MHz; fOSC≤ 25 MHz 0.5 x VDDIM −− V fOSC≥ 25 MHz; fOSC≤ 40 MHz Input voltage range limits for signal on XTAL1 VIX1 SR -1.7 + VDDIM − 1.7 V 2)

XC2000 Family / Compact Line Electrical Parameters Data Sheet 82 V1.2, 2012-07 Note: For crystal/resonator operation, it is strongly recommended to measure the oscillation allowance (negative resistance ) in the final target system (layout) to determine the optimum parameters for oscillator operation. The manufacturers of cryst als and ceramic resonato rs offer an oscillator evaluation service. This evaluation checks the crysta l/resonator specification limits to ensure a reliable oscillatior operation. Figure 19 External Clock Drive XTAL1 2) Overload conditions must not occur on pin XTAL1. MC_EXTCLOCK tOSC = 1/fOSC VOFF VAX1 0.1 VAX 1

0.9 VAX 1

XC2000 Family / Compact Line Electrical Parameters Data Sheet 83 V1.2, 2012-07

4.7.4 Pad Properties

The output pad drivers of the XC2220U can operate in several user-selectable modes. Strong driver mode allows controlling ex ternal components requiring higher currents such as power bridges or LEDs. Reducing th e driving power of an output pad reduces electromagnetic emissions (E ME). In strong driver mode, selecting a slower edge reduces EME. The dynamic behavior, i.e. the rise time and fall time, depends on the applied external capacitance that must be charged and discharged. Timing values are given for a capacitance of 20 pF, unless otherwise noted. In general, the performance of a pad driver depends on the available supply voltage VDDP. Therefore the following tables list the pad parameters for the upper voltage range and the lower voltage range, respectively. Note: These parameters are not subject to production test but verified by design and/or characterization. Note: Operating Conditions apply. Table 30 is valid under the following conditions: VDDP≤ 5.5 V; VDDPtyp. 5 V; VDDP≥ 4.5 V Table 30 Standard Pad Parameters for Upper Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Maximum output driver current (absolute value)1) IOmax CC −− 3.0 mA Driver_Strength =M e d i u m −− 5.0 mA Driver_Strength =S t r o n g −− 0.5 mA Driver_Strength =W e a k Nominal output driver current (absolute value) IOnom CC −− 1.0 mA Driver_Strength =M e d i u m −− 1.6 mA Driver_Strength =S t r o n g −− 0.25 mA Driver_Strength =W e a k

XC2000 Family / Compact Line Electrical Parameters Data Sheet 84 V1.2, 2012-07 Rise and Fall times (10% - 90%) tRF CC −− 38 + 0.6 x CL ns CL≥ 20 pF; CL≤ 100 pF; Driver_Strength =M e d i u m −− 1 + 0.45 x CL ns CL≥ 20 pF; CL≤ 100 pF; Driver_Strength =S t r o n g; Driver_Edge= Soft −− 16 + 0.45 x CL ns CL≥ 20 pF; CL≤ 100 pF; Driver_Strength =S t r o n g; Driver_Edge= Slow −− 200 + 2.5 x CL ns CL≥ 20 pF; CL≤ 100 pF; Driver_Strength =W e a k 1) The total output current that may be drawn at a giv en time must be limited to protect the supply rails from damage. For any group of 16 neighboring output pins , the total output current in each direction ( ΣIOL and Σ- IOH) must remain below 25 mA. Table 31 Standard Pad Parameters for Lower Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Maximum output driver current (absolute value)1) IOmax CC −− 1.8 mA Driver_Strength =M e d i u m −− 3.0 mA Driver_Strength =S t r o n g −− 0.3 mA Driver_Strength =W e a k Table 30 Standard Pad Parameters for Upper Voltage Range (cont’d) Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max.

XC2000 Family / Compact Line Electrical Parameters Data Sheet 85 V1.2, 2012-07 Nominal output driver current (absolute value) IOnom CC −− 0.8 mA Driver_Strength =M e d i u m −− 1.0 mA Driver_Strength =S t r o n g −− 0.15 mA Driver_Strength =W e a k Rise and Fall times (10% - 90%) tRF CC −− 73 + 0.85 x CL ns CL≥ 20 pF; CL≤ 100 pF; Driver_Strength =M e d i u m −− 6 + 0.6 x CL ns CL≥ 20 pF; CL≤ 100 pF; Driver_Strength =S t r o n g; Driver_Edge= Soft −− 33 + 0.6 x CL ns CL≥ 20 pF; CL≤ 100 pF; Driver_Strength =S t r o n g; Driver_Edge= Slow −− 385 + 3.25 x CL ns CL≥ 20 pF; CL≤ 100 pF; Driver_Strength =W e a k 1) The total output current that may be drawn at a giv en time must be limited to protect the supply rails from damage. For any group of 16 neighboring output pins , the total output current in each direction ( ΣIOL and Σ- IOH) must remain below 25 mA. Table 31 Standard Pad Parameters for Lower Voltage Range (cont’d) Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max.

XC2000 Family / Compact Line Electrical Parameters Data Sheet 86 V1.2, 2012-07

4.7.5 Synchronous Serial Interface Timing

The following parameters are applicable for a USIC channel operated in SSC mode. Note: These parameters are not subject to production test but verified by design and/or characterization. Note: Operating Conditions apply. Table 32 is valid under the following conditions: CL=2 0p F ; SSC=m a s t e r; voltage_range= upper Table 32 USIC SSC Master Mode Timing for Upper Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Slave select output SELO active to first SCLKOUT transmit edge t1 CC tSYS - 81) 1) tSYS = 1 / fSYS −− ns Slave select output SELO inactive after last SCLKOUT receive edge t2 CC tSYS - 61) −− ns Data output DOUT valid time t3 CC -6 − 9n s Receive data input setup time to SCLKOUT receive edge t4 SR 31 −− ns Data input DX0 hold time from SCLKOUT receive edge t5 SR -4 −− ns

XC2000 Family / Compact Line Electrical Parameters Data Sheet 87 V1.2, 2012-07 Table 33 is valid under the following conditions: CL=2 0p F ; SSC=m a s t e r; voltage_range= lower Table 34 is valid under the following conditions: CL=2 0p F ; SSC= slave ; voltage_range= upper Table 33 USIC SSC Master Mode Timing for Lower Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Slave select output SELO active to first SCLKOUT transmit edge t1 CC tSYS - 101) 1) tSYS = 1 / fSYS −− ns Slave select output SELO inactive after last SCLKOUT receive edge t2 CC tSYS - 91) −− ns Data output DOUT valid time t3 CC -7 − 11 ns Receive data input setup time to SCLKOUT receive edge t4 SR 40 −− ns Data input DX0 hold time from SCLKOUT receive edge t5 SR -5 −− ns Table 34 USIC SSC Slave Mode Timi ng for Upper Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Select input DX2 setup to first clock input DX1 transmit edge1) t10 SR 10 −− ns Select input DX2 hold after last clock input DX1 receive edge1) t11 SR 7 −− ns Receive data input setup time to shift clock receive edge t12 SR 7 −− ns

XC2000 Family / Compact Line Electrical Parameters Data Sheet 88 V1.2, 2012-07 Table 35 is valid under the following conditions: CL=2 0p F ; SSC= slave ; voltage_range= lower Data input DX0 hold time from clock input DX1 receive edge1) t13 SR 5 −− ns Data output DOUT valid time t14 CC 7 − 33 ns 1) These input timings are valid for asyn chronous input signal handling of slave select input, shift clock input, and receive data input (bits DXnCR.DSEN = 0). Table 35 USIC SSC Slave Mode Timi ng for Lower Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Select input DX2 setup to first clock input DX1 transmit edge1) 1) These input timings are valid for asyn chronous input signal handling of slave select input, shift clock input, and receive data input (bits DXnCR.DSEN = 0). t10 SR 10 −− ns Select input DX2 hold after last clock input DX1 receive edge1) t11 SR 7 −− ns Receive data input setup time to shift clock receive edge1) t12 SR 7 −− ns Data input DX0 hold time from clock input DX1 receive edge t13 SR 5 −− ns Data output DOUT valid time t14 CC 8 − 41 ns Table 34 USIC SSC Slave Mode Timi ng for Upper Voltage Range (cont’d) Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max.

XC2000 Family / Compact Line Electrical Parameters Data Sheet 89 V1.2, 2012-07 Figure 20 USIC - SSC Master/Slave Mode Timing Note: This timing diagram shows a standard configuration where the slave select signal is low-active and the serial clock signal is not shifted and not inverted. t2t1 USIC_SSC_TMGX.VSD Clock Output SCLKOUT Data Output DOUT t3 t3 Data valid First Transmit Edge Data Input DX0 Select Output SELOx Active Master Mode Timing Slave Mode Timing t11t10 Clock Input DX1 Data Output DOUT t14 t14 Datavalid Data Input DX0 Select Input DX2 Active t13 t12 Transmit Edge: with this clock edge, transmit data is shifted to transmit data output. Receive Edge : with this clock edge, receive data at receive data input is latched. Receive Edge Last Receive Edge InactiveInactive Transmit Edge InactiveInactive First Transmit Edge Receive Edge Transmit Edge Last Receive Edge Data valid Datavalid t12 t13 Drawn for BRGH.SCLKCFG = 00B. Also valid for for SCLKCFG = 01B with inverted SCLKOUT signal .

XC2000 Family / Compact Line Electrical Parameters Data Sheet 90 V1.2, 2012-07

4.7.6 Debug Interface Timing

The debugger can communicate with the XC2220U via 1-pin SPD interface, via the 2- pin DAP interface or via the standard JTAG interface. Debug via DAP The following parameters are applicable for communication through the DAP debug interface. Note: These parameters are not subject to production test but verified by design and/or characterization. Note: Operating Conditions apply. Table 36 is valid under the following conditions: CL= 20 pF; voltage_range= upper Table 36 DAP Interface Timing for Upper Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. DAP0 clock period t11 SR 100 1) 1) The debug interface cannot operate faster than the overall system, therefore t11 ≥ tSYS. −− ns DAP0 high time t12 SR 8 −− ns DAP0 low time t13 SR 8 −− ns DAP0 clock rise time t14 SR −− 4n s DAP0 clock fall time t15 SR −− 4n s DAP1 setup to DAP0 rising edge t16 SR 6 −− ns pad_type= stan dard DAP1 hold after DAP0 rising edge t17 SR 6 −− ns pad_type= stan dard DAP1 valid per DAP0 clock period2) 2) The Host has to find a suitable sampling point by analyzing the sync telegram response. t19 CC 92 95 − ns pad_type= stan dard

XC2000 Family / Compact Line Electrical Parameters Data Sheet 91 V1.2, 2012-07 Table 37 is valid under the following conditions: CL= 20 pF; voltage_range= lower Figure 21 Test Clock Timing (DAP0) Table 37 DAP Interface Timing for Lower Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. DAP0 clock period t11 SR 100 1) 1) The debug interface cannot operate faster than the overall system, therefore t11 ≥ tSYS. −− ns DAP0 high time t12 SR 8 −− ns DAP0 low time t13 SR 8 −− ns DAP0 clock rise time t14 SR −− 4n s DAP0 clock fall time t15 SR −− 4n s DAP1 setup to DAP0 rising edge t16 SR 6 −− ns pad_type= stan dard DAP1 hold after DAP0 rising edge t17 SR 6 −− ns pad_type= stan dard DAP1 valid per DAP0 clock period2) 2) The Host has to find a suitable sampling point by analyzing the sync telegram response. t19 CC 87 92 − ns pad_type= stan dard MC_DAP0

0.9 VDDP

0.5 VDDP

0.1 VDDP

XC2000 Family / Compact Line Electrical Parameters Data Sheet 93 V1.2, 2012-07 Debug via JTAG The following parameters are applicable for communication through the JTAG debug interface. The JTAG module is fully compliant with IEEE1149.1-2000. Note: These parameters are not subject to production test but verified by design and/or characterization. Note: Operating Conditions apply. Table 38 is valid under the following conditions: CL= 20 pF; voltage_range= upper Table 38 JTAG Interface Timing for Upper Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. TCK clock period t1 SR 100 1) 1) The debug interface cannot operate faster than the overall system, therefore t1 ≥ tSYS. −− ns 2) 2) Under typical conditions, the JTAG interface can operate at transfer rates up to 10 MHz. TCK high time t2 SR 16 −− ns TCK low time t3 SR 16 −− ns TCK clock rise time t4 SR −− 8n s TCK clock fall time t5 SR −− 8n s TDI/TMS setup to TCK rising edge t6 SR 6 −− ns TDI/TMS hold after TCK rising edge t7 SR 6 −− ns TDO valid from TCK falling edge (propagation delay)3) 3) The falling edge on TCK is used to generate the TDO timing. t8 CC − 29 32 ns TDO high impedance to valid output from TCK falling edge4)3) 4) The setup time for TDO is given implicitly by the TCK cycle time. t9 CC − 29 32 ns TDO valid output to high impedance from TCK falling edge3) t10 CC − 29 32 ns TDO hold after TCK falling edge3) t18 CC 5 −− ns

XC2000 Family / Compact Line Electrical Parameters Data Sheet 94 V1.2, 2012-07 Table 39 is valid under the following conditions: CL= 20 pF; voltage_range= lower Table 39 JTAG Interface Timing for Lower Voltage Range Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. TCK clock period t1 SR 100 1) 1) The debug interface cannot operate faster than the overall system, therefore t1 ≥ tSYS. −− ns TCK high time t2 SR 16 −− ns TCK low time t3 SR 16 −− ns TCK clock rise time t4 SR −− 8n s TCK clock fall time t5 SR −− 8n s TDI/TMS setup to TCK rising edge t6 SR 6 −− ns TDI/TMS hold after TCK rising edge t7 SR 6 −− ns TDO valid from TCK falling edge (propagation delay)2) 2) The falling edge on TCK is used to generate the TDO timing. t8 CC − 39 43 ns TDO high impedance to valid output from TCK falling edge 3)2) 3) The setup time for TDO is given implicitly by the TCK cycle time. t9 CC − 39 43 ns TDO valid output to high impedance from TCK falling edge2) t10 CC − 39 43 ns TDO hold after TCK falling edge2) t18 CC 5 −− ns

XC2000 Family / Compact Line Electrical Parameters Data Sheet 95 V1.2, 2012-07 Figure 24 Test Clock Timing (TCK) Figure 25 JTAG Timing MC_JTAG _TCK MC_JTAG t18

XC2000 Family / Compact Line Electrical Parameters Data Sheet 96 V1.2, 2012-07 Debug via SPD The SPD interface will work with standard SPD tools having a sample/output clock frequency deviation of +/- 5% or less. Note: For further details please refer to application note AP24004 in section SPD Timing Requirements. Note: Operating Conditions apply.

XC2000 Family / Compact Line Package and Reliability Data Sheet 97 V1.2, 2012-07

5 Package and Reliability

The XC2000 Family devices use the package type:

  • PG-VQFN (Plastic Green - Very Thin Profile Quad Flat Non-Leaded Package) The following specifications must be regar ded to ensure proper integration of the XC2220U in its target environment.

5.1 Packaging

These parameters specify the packaging rather than the silicon. Note: To improve the EMC behavior, it is recommended to connect the exposed pad to the board ground, independent of the thermal requirements. Board layout examples are given in an application note. Package Compatibility Considerations The XC2220U is a member of the XC2000 Fa mily of microcontrollers. It is also compatible to a certain extent with members of similar families or subfamilies. Each package is optimized for the device it houses. Therefore, there may be slight differences between packages of the same pin-count but for different device types. In Table 40 Package Parameters (PG-VQFN-48-54) Parameter Symbol Limit Values Unit Notes Min. Max. Exposed Pad Dimension Ex × Ey – 5.2 x 5.2 mm – Power Dissipation PDISS –0 . 6 W – Thermal resistance Junction-Ambient RΘJA – 75 K/W No thermal via, 2-layer1) 1) Device mounted on a 2-layer JEDEC board (according to JESD 51-3) without thermal vias; exposed pad not soldered.

51 K/W No thermal via,

4-layer2) 2) Device mounted on a 4-layer JEDEC board (according to JESD 51-7) without thermal vias; exposed pad not soldered.

46 K/W 4-layer, no pad 3)

3) Device mounted on a 4-layer JEDEC board (according to JESD 51-7) with thermal vias; exposed pad not soldered.

36 K/W 4-layer, pad 4)

4) Device mounted on a 4-layer JEDEC board (according to JESD 51-7) with thermal vias; exposed pad soldered to the board.

XC2000 Family / Compact Line Package and Reliability Data Sheet 98 V1.2, 2012-07 particular, the size of the Exposed Pad (if present) may vary. If different device types are considered or planned for an application, it must be ensured that the board layout fits all packages under consideration. Package Outlines Figure 26 PG-VQFN-48-54 (Plastic Green Thin Quad Flat Package) All dimensions in mm. You can find complete information about Infineon packages, packing and marking in our Infineon Internet Page “Packages”: http://www.infineon.com/packages 0.9 MAX. SEATING PLANE Index Marking +0.03 0.4 x 45˚ (0.65) Index Marking (5.2) 7±0.1 A 6.8 6.8 48x 0.08 (0.2) 0.05 MAX.C 7±0.1 B 11 x 0.5 = 5.5 0.5 0.5 11 x 0.5 = 5.5 0.4±0.07 (6.2) (6.2) (5.2) 0.23 0.26 0.15 M±0.05 ±0.03 48x

0.1 A B C

XC2000 Family / Compact Line Package and Reliability Data Sheet 99 V1.2, 2012-07

5.2 Thermal Considerations

When operating the XC2220U in a system, the total heat generated in the chip must be dissipated to the ambient environment to prevent overheating and the resulting thermal damage. The maximum heat that can be dissipated dep ends on the package and its integration into the target board. The “Thermal resistance RΘJA” quantifies these parameters. The power dissipation must be limited so that the average junction temperature does not exceed 150 °C. The difference between junction temperature and ambient temperature is determined by ΔT = (PINT + PIOSTAT + PIODYN) × RΘJA The internal power consumption is defined as PINT = VDDP × IDDP (switching current and leakage current). The static external power consumption caused by the output drivers is defined as PIOSTAT = Σ((VDDP-VOH) × IOH) + Σ(VOL × IOL) The dynamic external power consumption caused by the output drivers (PIODYN) depends on the capacitive load connected to the respective pins and their switching frequencies. If the total power dissipation for a given system configuration exceeds the defined limit, countermeasures must be taken to ensure proper system operation:

  • Reduce VDDP, if possible in the system
  • Reduce the system frequency
  • Reduce the number of output pins
  • Reduce the load on active output drivers

XC2000 Family / Compact Line Package and Reliability Data Sheet 100 V1.2, 2012-07

5.3 Quality Declarations

The operation lifetime of t he XC2220U depends on the app lied temperature profile in application. For a typical example, please refer to Table 42; for other profiles, please contact your Infineon counterpart to calculate the specific lifetime within your application. Table 41 Quality Parameters Parameter Symbol Values Unit Note / Test ConditionMin. Typ. Max. Operation lifetime tOP CC −− 20 a See Table 42 and Table 43 ESD susceptibility according to Human Body Model (HBM) VHBM SR −− 2000 V EIA/JESD22- A114-B Moisture sensitivity level MSL CC −− 3 − JEDEC J-STD-020C Table 42 Typical Usage Temperature Profile Operating Time (Sum = 20 years) Operating Temperature Notes 1200 h TJ = 150°C Normal operation 3600 h TJ = 125°C Normal operation 7200 h TJ = 110°C Normal operation 12000 h TJ = 100°C Normal operation 60…70°C Power reduction Table 43 Long Time Maximum Storage Temperature Profile Operating Time (Sum = 20 years) Operating Temperature Notes 2000 h TJ = 150°C Normal operation 16000 h TJ = 125°C Normal operation 6000 h TJ = 110°C Normal operation 151200 h TJ ≤ 150°C No operation

www.infineon.com Published by Infineon Technologies AG