  • Delivers agility at all layers of the data center stack
  • Provides high-density 100/40 GbE spine and leaf connectivity in a 1U fix ed form factor
  • Includes a programmable ASIC to accelerate adoption of new protocols and technologies
  • Utilizes the Integrated Application Hosting Architecture and Extreme SLX Visibility Services for fle xible, real- time monitoring of virtualized,dynamic workloads to streamline troubleshooting
  • Provides payload timestamping to more accurately set and measure performance SLAs
  • Incorporates turnkey and customizable automation for the entire network lifecycle Programmable, Flexible, High-Density Switch As data centers and cloud service providers embrace new high- performance servers and distributed applications, they increasingly need dense 100/40 GbE switches for leaf and spine c onfigur ations. Traditionally, infrastructure has been slow to evolve, and it can be a barrier to innovation. With fle xibilit y at all layers of the data center stack, IT teams can drive agility. The ExtremeSwitching™ SLX 9240 Switch is designed to help organizations stay ahead of this application- and data-driven network transformation without compromising performance. The SLX 9240 delivers the high-density 100 GbE connectivity required by high-end enterprise and cloud data centers. The underlying hardware is programmable, enabling a faster transition to emerging protocols and new technologies. Workload visibility combined with end-to-end network visibility helps infrastructure teams continue to improve SLAs as they increase network virtualization. The SLX 9240 is a fix ed 100/40 GbE leaf and spine switch in a 1U form factor that supports 24 MB of dynamically shared packet buffer and an overall throughput of 3.2 Tbps/1.3 Bpps. It can be c onfigur ed as a leaf switch or connect to 40 or 100 GbE uplinks from leaf switches. By leveraging this high-density switch, data center networks can dramatically improve power, space, and cooling effic ienc ies, even at scale. A programmable ASIC enables the adoption of new protocols and technologies through an OS, rather than a forklift upgrade. Payload timestamping improves the accuracy of performance SLA setting and measurement. Data Sheet SLX 9240 www.extremenetworks.com 1

Modular, Virtualized Operating System The SLX 9240 runs Extreme SLX-OS, a fully virtualized Linux-based operating system that delivers process level resiliency and fault isolation. SLX-OS supports advanced switching features and is highly programmable with support for REST API with the YANG data model, Python, and NETCONF — enabling full lifecycle automation. In addition, SLX-OS supports running third-party and customized monitoring, troubleshooting, and analytics applications. SLX Packet Broker for Carrier-Grade Visibility Network tr affic growth in carrier networks is driving scalability and management challenges that service providers must urgently address. Wire-speed visibility into these networks is critical to enable effective control of this tr affic as it scales. Part of a broad portfolio of network visibility solutions, the SLX 9240 can be deployed as a Network Packet Broker. From the aggregation layer of the network, SLX 9240 curates tr affic and steers replicated flo w s to relevant analytics platforms to provide (for instance) DDoS mitigation, congestion management, differentiated treatment of voice and video, and billing. The SLX 9240 offers 100 GbE (32), 40 GbE (32), 25 GbE (128), and10 GbE (128) interface capacities. For more information on the full portfolio of Extreme Networks Packet Broker solutions, visit https://www.extremenetworks.com/solutions/service- provider/visibility SLX Visibility Services As network complexity increases, isolated data points at the physical or virtual network layer provide little insight into the criticality of an issue. For example, bursty storage backup tr affic slowing down an internal Web site is a lower priority than a slowdown for a revenue-generating application. Network administrators need workload context across the network to ensure the appropriate action is taken in each case. SLX Visibility Services help simplify network operations with embedded visibility from the physical network to application workloads. By combining physical and virtual network tr affic data with overlay and workload information across multiple network layers, this solution enables diverse, rule-based actions to maintain performance and mitigate risk. Other key functions include:

  • Pervasive visibility at scale across the network for seamless support of highly distributed multitier application workloads
  • Rich multilayer c lassification (such as IP and MAC addresses, port numbers, VNIs) and workload matching with network-wide scale
  • Automated application of rule-based actions (such as count, drop, mirror) to incoming network tr affic www.extremenetworks.com 2

SLX 9240 Switch Spec ifications Switch Form Factor 1U Switching Bandwidth (data rate, full duplex) 3.2 Tbps in and 3.2 Tbps out for a sum total of 6.4 Tbps Forwarding Capacity (data rate, full duplex) (L2) 2.4 Bpps, (L3) 600 Mpps line-rate performance Port-to-port latency 2.5 usec Architecture Store and Forward Supported 100/40GbE Ports 32 Power Supplies Two internal, redundant, field-r eplac e able, load-sharing AC or DC power supplies Cooling Fans Five field-r eplac e able fans Dynamically Shared Packer Buffer 24MB Power Power Inlet (AC) C13 Input Voltage 90V to 264 V or 40.8 V to 60 V DC Input Line Frequency 47Hz to 63 Hz Inrush Current 25 A peak Maximum Current 12A/AC, 14 A/DC Typical Power Consumption 84W | Two AC PSU, fiv e fan trays, 10% tr affic , low fan speed Maximum Power Consumption 581W | Two AC PSU, six fan trays, 100% tr affic , high fan speed Power Supply Rated Maximum (AC) 650W Switch Power Consumption DC PSU 563 W; AC PSU 581 W Environment Humidity 5% to 95% at 50°C Altitude Up to 3,000 m safety; 60 m to 4,000 m operational Shock (operational) 20 G, 11 ms, half-sine wave Vibration (operational) 1G sine, 0.4 gms random, 5 Hz to 500 Hz Air flo w 134 CFM (estimated with two PSU, six fan trays) Acoustics(25°C) 52 dBA MTBF (25°C) 327,539 hours www.extremenetworks.com 3

Connector Options 10 GbE SFP+ (via splitter cable) 100 GbE QSFP-28

40 GbE QSFP+

Out-of-band Ethernet management: 10/100/1000 Mbps RJ-45 Console management: RJ45 serial port and USB type-C port with serial communication device class support Storage: USB port, standard-A plug Maximum MAC Addresses Up to 48,000 Maximum VLANs 4,096 Maximum Routes (in hardware) Up to 40,000 Maximum ACLs 512 Maximum Members in a Standard LAG 16 Maximum Per-Port Priority Pause Level 8 Maximum Switches an mLAG Can Span 2 Maximum IPv4 Unicast Routes 48,000 Maximum IPv6 Unicast Routes 8,000 DCB Priority Flow Control Classes 4 Maximum Jumbo Frame Size 10,000 bytes QoS Priority Queues (per port) 8 Standards Compliance IEEE Compliance Ethernet IEEE 802.1D Spanning Tree Protocol IEEE 802.1s Multiple Spanning Tree IEEE 802.1w Rapid Rec onfigur ation of Spanning Tree Protocol IEEE 802.3 Ethernet IEEE 802.3ad Link Aggregation with LACP IEEE 802.3ae 10G Ethernet IEEE 802.1Q VLAN Tagging IEEE 802.1p Class of Service Prioritization and Tagging IEEE 802.1v VLAN Classification by Protocol and Port IEEE 802.1AB Link Layer Discovery Protocol (LLDP) IEEE 802.3x Flow Control (Pause Frames) IEEE 802.3ab 1000BASE-T IEEE 802.3z 1000BASE-X RFC Compliance For more information on the supported RFCs, visit https:// www.extremenetworks.com/support/documentation. Search for the Extreme SLX-OS Scale and Standards Matrix document for your version of SLX-OS. www.extremenetworks.com 4

Ordering Information

BR-SLX-9240-32C SLX 9240-32C Switch. No Fans/Power supplies included. 32x 100GE/40GE. XBR-3250CFM-FAN-F SLX Fixed FAN Front to Back air flo w XBR-3250CFM-FAN-R SLX Fixed FAN Back to Front air flo w XBR-ACPWR-650-F SLX Fixed AC 650W Power Supply Front to Back air flo w . Power cords not included. XBR-ACPWR-650-R SLX Fixed AC 650W Power Supply Back to Front air flo w . Power cords not included. XBR-DCPWR-650-F SLX Fixed DC 650W Power Supply Front to Back air flo w . Power cords not included. XBR-DCPWR-650-R SLX Fixed DC 650W Power Supply Back to Front air flo w . Power cords not included. XBR-R000297 SLX 9140/9240/9540/9640 Fixed Rack Mount kit 4-post mid/ flush mount compatible Upgrade License Part Number Description BR-SLX-9240-ADV-LIC Advanced License for BR-SLX-9240 License includes OVSDB integration, BGP EVPN, Guest VM, gRPC, 1588 BC, Timestamping, TPVM and NPB feature. The NPB feature set includes the following features: T r affic aggregation, T r affic replication (Transparent VLAN Flooding), L2 and L3 ACL, Route-map, Hash-based load balancing, and Timestamping. ©2023 Extreme Networks, Inc. All rights reserved. Extreme Networks and the Extreme Networks logo are trademarks or registered trademarks of Extreme Networks, Inc. in the United States and/or other countries. All other names are the property of their respective owners. For additional information on Extreme Networks Trademarks please see http://www.extremenetworks.com/company/legal/trademarks. Spec ifications and product availability are subject to change without notice. 28jul23 www.extremenetworks.com 5