WRP-SX ETA-USA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com DERATING CURVE EFFICIENCY CURVE
450 WATT
Specifications<AC/DC> WRP**SX-U 450WATTS/SINGLE Input Voltage Input Current Input Range Input Frequency Input Frequency Range Phase Inrush Current *1 Efficiency [%] (typical) *2 80 82 84 85 85 85 86 86 Model WRP05SX-U WRP06SX-U WRP12SX-U WRP15SX-U W RP24SX-U WRP30SX-U WRP36SX-U WRP48SX-U Input Characteristic AC115/230V 11A at AC115/6A at AC230 AC85-132V/170-264V(DC220-360V) 50/60Hz 47-440Hz Single 12A(maximum) at AC115/24A(maximum) at AC230V
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Specifications<AC/DC> WRP**SX-U 450WATTS/SINGLE Output Voltage [V] 5 6 12 15 24 30 36 48 Voltage Adjust Range Ripple and Noise mVp-p *3 150 160 220 250 340 400 460 580 Regulation a.Statistic Line Regulation mV 25 30 60 75 120 150 180 240 b.Statistic Load Regulation mV 50 60 120 150 240 300 360 480 c.Temperature Coefficient *4 d.DriftmV *5 40 45 75 90 135 165 195 255 e.Dynamic Load Regulation mV *6 f.Recovery Time *6 Rise up time Hold up time Remote Sense Remote On/Off Power Fail Detection Parallel/series Operation Operating Temperature *7 Operating Humidity Storage Temperature Storage Humidity Isolation Resistance Vibration Shock Cooling ? Leakage Current ? Line Conducted Noise ? Weight (typical) ? MTBF [H] ? Switching FrequencykHz *5 for 7hour period after 1hour warm-up at 25℃ and rated input/output *6 when load changed from 25% to 75% of rated output current rapidly at AC115/230V input *7 safety approved at 25℃ *2 at DC260V input and rated output *3 measured by a bayonet probe at the end of a pair of 15cm long wires terminated with a 330uF electrolytic capacitor and a 100uF ceramic capacitor in parallel at a 0 to 100MHz bandwidth *4 at -5 to +50℃ 2000g 155,000 135 *1 at cold start ? Safety UL: UL1950 C-UL: CSA C22.2 No.234 (Level 5) 294m/s Forced Air(fan installed) 1mA(maximum) at 25℃,rated input/output and rated input frequency Built to meet FCC Part15-B Class A Primary-Secondary-Frame Ground 50MΩ(minimum) by DC500V insulation tester 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s2, 20minutes' period for 60minutes each along X,Y,Z axes(non-operating) 10 to 85%RH(non-condensing) Withstanding Voltage Primary-Secondary AC3,000V for 1minute Primary-Frame Ground AC2,500V for 1minute Secondary-Frame Ground AC500V for 1minute Environmental -5 to +50℃ 30 to 85%RH(non-condensing) -20 to +85℃ available available available available Functions Overcurrent Protection ≧105% of Rated Output Current[A] Current Limiting with automatic recovery Overvoltage Protection ≧110% of Rated Output Voltage[V] Output shutdown(to reset,leave 1minute after shut-off) not specified not specified 500mS(maximum) at 25℃ and rated input/output 20mS(minimum) at 25℃ and rated input/output Output Characteristic +/- 10% of Rated Output Voltage(at no load within the input range) 0.03%/℃ Model WRP05SX-U WRP06SX-U WRP12SX-U WRP15SX-U W RP24SX-U WRP30SX-U WRP36SX-U WRP48SX-U
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com DIMENSION DIAGRAM