EPF400-380 ETA-USA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

FEATURES: UnitMODEL/CHANNEL VNorminal Voltage VRated Output Voltage Line Regulation Load Regulations Voltage Range Voltage Tolerance Ripple & Noise Max. mV V V mV mV 400W Power Supply ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 ET -U The Power Professionals A SA OUTPUT EPF400-380 400W when AC85~264V or DC 120V to 220V input* 630W when AC 170~264V input* 340~380V ±10% of Rated Output Voltage(at no load within the input range) 350 ± 2[V] At AC 100V input, 400W output 30/40, measured by a Bayonet Probe at the end of the output connector with 20MHz bandwidth scope 30V Max at PFC operating range or DC120 to 220V input Output voltage will be bridge rectified when AC 255~264V input 50V max at PFC operating range or DC 120 to 220V input Changing load from 0 to the rated value with fixed input voltage

  • PFC Unit for ET-series
  • Power Factor 0.99 at AC240V Input
  • High Efficiency 95% in AC240V input by Convection Cooling
  • Wide Range Input (AC85-264V)

(1) Input - Output (2) Input - F.G (3) Output - F.G Operating temp. & Humidity Storage temp. & Humidity Vibration - Isolation Resistance - Shock - Line Harmonics - Mounting Direction - Over Voltage Protection Over Current Protection V A 400W Power Supply ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 ET - The Power Professionals A Inrush Current Leakage Current A mA Current Input Voltage Range V Input Voltage V A USA Voltage, Frequency V Safety - Line Conducted Noise - INPUT FUNCTION ELECTRICAL ISOLATION Environment EPF400-380 -10 to +50°C; 20 to 90%/RH(non-condensing) -20 to +85°C; 20 to 90%/RH(non-condensing) 5-10Hz: 10mm, 10-55Hz: 19.6m/s^2, 3 minute periods along X,Y,Z axes(non-operating) 196m/s^2 except for terminals UL: UL60950-1, C-UL: EN60950-1 and the electrical appliance and material safety law based None (Overload and output short breaks the power supply down) 25V Max at -10 to +50°C ambient temperature AC100-240V 5.5A; AC200-240V 4.1A; DC120-220V 4A AC85~264V & DC120~220V @400W Output; AC170~264V @630W Output 2-0.9A 25A(typ.) at AC100V; 50A(typ.) at AC240V; 35A (typ.) at DC220V 1mA(maximum)at 25°C (rated input/output and rated input frequency) Horizontal (PSU bottom as bottom); Vertical (Q1 side placed as bottom) Primary-Secondary-Frame Ground 50MΩ(minimum) by DC500V insulation tester Input-Output: Non-isolated >395V after detected the overvoltage, shut the output and stop the operation. To restart, remove the cause of failure and turn ON again after shut-off Bridge rectified voltage will appear at Output when operation stopped.) Built to meet EN55022 Class A, EN55022 Class B using external line filter. Built to meet IEC61000-3-2 Sens-current 20 mA Input-FG (Chassis): AC 2,500V for 1 minute 50/60Hz; 45-65Hz Cooling - Convection

ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 ET - The Power Professionals A USA Terminal Connection

ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 ET - The Power Professionals A USA

ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 ET - The Power Professionals A USA Mechanical Drawings