Features
MTBF 37,000 hours Power fail function Options Remote Control option available Combination of wire and harness General Description These 600W single output switching power supplies were developed for use in 82~132V and 170~264V input ranges. They are miniature in size and are high in efficiency. Application Intelligence equip, communicators, industrial control machines, instruments Input Input Voltage: Input Voltage Range: Frequency: Frequency Range: Phase: Inrush Current: *1 115/230VAC AC 85~132/170~264V 50/60Hz 47~440 Hz Single 14A max at 115Vac full load AACC//DDCC SSWWIITTCCHHIINNGG PPOOWWEERR SSUUPPPPLLYY SSIINNGGLLEE CCHHAANNNNEELL OOUUTTPPUUTT
660000 WWAATTTTSS
8855~~113322VV//117700~~226644VV
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com Output Models Characteristic Unit WRG05 SX-U WRG06 SX-U WRG12 SX-U WRG15 SX-U WRG24 SX-U WRG30 SX-U WRG36 SX-U WRG48 SX-U Output Voltage Vdc 5 6 12 15 24 30 36 48 Output Current A 120 95 53 42 28 22 16 14 Ripple &Noise(max) mVpp (Output V*1%)+100mV Voltage Adjust Range V ±10% Rise time mS 500mS max Hold up time mS 20mS min. Regulation a. Line Regulation [max] mV 0.5% max. b. Load Regulation mV 1% max. c. Temperature Coefficient 0.03%/°C d. Drift(maximum) mV (Output V x 0.5%) + 15mV/8H (after 1 hour) e. Dynamic Load Regulation (typ.) *2 mV Info soon f. Recovery Time *2 mS Info soon Efficiency % 80~87% typ. Power Factor No information
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com Environmental Specification Operating Temperature*3 -5 to +50 °C Operating Humidity 30~85% RH Storage Temperature -20 to +85 °C Storage Humidity 10~85% RH Withstanding Voltage Primary-Secondary AC3,000V for 1minute Primary-Frame Ground AC2,500V for 1minute Secondary-Frame Ground AC1,000V for 1minute Isolation Resistance Primary-Secondary-Frame Ground 50M Ω(minimum) by DC500V insulation tester Vibration 5~10Hz:10mm double amplitude Shock 294m/s 2 Cooling Fan-cooled Leakage current 0.4mA Environmental Agencies Line Conducted Noise [EMI] Built to meet FCC-B Line Harmonic Distortion/Current Info soon Safety UL60950-1, C-UL(CSA60950-1) Function/Protection Over current Protection Fold back current limiter type with automatic recovery on removal of fault (constant current limiting) Over voltage Protection Breaking out voltage type with reclosing by input of power source Remote Sense Available Remote Control Available Series Operation Available Parallel Operation Available Driving Indicator No information Mechanical Dimension [mm] 170L x 200W x 93H Weight g ~2900g
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com