Wall Industries, Inc. Rev B WMIHPU25 SERIES Up to 25 Watts, Medical AC/DC Wall Mount Power Supplies 08/04/2014 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 1 of 4
FEATURES
Class II System RoHS Compliant Up to 25 Watts Output Power 85% High Efficiency Energy Star 2.0, Efficiency Level V 80-275VAC Input Voltage Range 100% Burn-In Tested Input to Output: 2MOPP Single Outputs Ranging from 3VDC to 55VDC -10°C to +70°C Operating Temperature Range Meets FCC Part-18 Class B & CISPR-11EN55011 Class B Emission Limits UL/cUL 3rd Edition Medical Approvals Interchangeable Plug Options: United States, Europe, Australia, & United Kingdom Types Optional Output Connectors Available SAFETY APPROVALS
DESCRIPTION
Size: Weight: 2.95 x 1.71 x 1.58 inches 7.05oz (200g) 75.0 x 43.5 x 40.2 mm AC Plug Types: Applications:
- Unites States (“U” Suffix) • Home Healthcare Equipment
- Europe (“E” Suffix) • Patient Monitors
- Australia (“A” Suffix”) • Blood Pressure Systems
- United Kingdom (“K” Suffix) • Portable Medical Devices
- ECG Machines The WMIHPU25 series of Class II medical AC/DC wall mount power supplies offers up to 25 watts of output power in a 2.95” x 1.71” x 1.58” package. This series consists of single output models ranging from 3VDC to 55VDC with an 80~275VAC input voltage range and a -10°C to +70°C operating temperature. This series meets FCC Part-18 Class B and CISPR-11 EN55011 Class B Emission Limits and has ANSI/AAMI ES 60601-1: 2005 (UL/cUL 3rd edition) and CE safety approvals. All units are RoHS and Energy Star Level V compliant. Plugs come in United States (“U” suffix), Europe (“E” suffix), Australia (“A” suffix), and United Kingdom (“K” suffix) types. Plugs are sold separately so please contact factory for ordering details. MODEL SELECTION TABLE Adjustable Voltage Range Adjustable Current RangeModel Number (1) Input Voltage Min Max Min Max Maximum Output Power Ripple & Noise Total Regulation Efficiency No Load Consumption WMIHPU25-101x 3 VDC 5 VDC 2.10 A 3.50 A 10.5W 66mVp-p ±5% 65% 0.2W WMIHPU25-102x 5 VDC 6 VDC 2.75 A 3.30 A 16.5W 50mVp-p ±5% 80% 0.3W WMIHPU25-103x 6 VDC 8 VDC 2.50 A 3.30 A 20W 70mVp-p ±5% 82% 0.3W WMIHPU25-104x 8 VDC 11 VDC 2.00 A 2.75 A 22W 90mVp-p ±5% 83% 0.3W WMIHPU25-105x 11 VDC 13 VDC 1.92 A 2.27 A 25W 100mVp-p ±5% 84% 0.3W WMIHPU25-106x 13 VDC 16 VDC 1.56 A 1.92 A 25W 100mVp-p ±5% 85% 0.3W WMIHPU25-107x 16 VDC 21 VDC 1.19 A 1.56 A 25W 100mVp-p ±5% 85% 0.3W WMIHPU25-108x 21 VDC 27 VDC 0.92 A 1.19 A 25W 100mVp-p ±3% 86% 0.3W WMIHPU25-109x 27 VDC 33 VDC 0.75 A 0.92 A 25W 100mVp-p ±3% 86% 0.3W WMIHPU25-110x 33 VDC 40 VDC 0.62 A 0.75 A 25W 100mVp-p ±3% 86% 0.3W WMIHPU25-111x 40 VDC 48 VDC 0.53 A 0.62 A 25W 100mVp-p ±3% 86% 0.3W WMIHPU25-112x 80 ~ 275VAC 48 VDC 55 VDC 0.45 A 0.53 A 25W 100mVp-p ±3% 86% 0.3W NOTES 1. The “ x” in the model number can be “U” for United States type plug; “E” for Europe type plug, “A” for Australia type plug, or “K” for United Kingdom type plug. Plugs are sold separately so please contact factory for ordering details. 2. Output can provide up to peak load when power supply starts up. Continuous staying in more than rated load is not allowed. 3. At factory, in 60% rated load condition, each output is checked to be within voltage accuracy. 4. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. 5. Load regulation is defined by changing ±40% of measured output load from 60% rated load. 6. Ripple & noise is measured by using 20MHz limited bandwidth and with 0.47F capacitor in parallel across the output at nominal line and rated load. 7. Hold-up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated load and nominal line. 8. Optional output connectors are available for this series. Please call factory for ordering details.
Wall Industries, Inc. Rev B WMIHPU25 SERIES Up to 25 Watts, Medical AC/DC Wall Mount Power Supplies 08/04/2014 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 2 of 4 TECHNICAL SPECIFICATIONS: WMIHPU25 SERIES All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Typ Max Unit INPUT SPECIFICATIONS Safety Approvals Input Voltage Range 100 240 Input Voltage Derating linearly from 100% load at 90VAC to 80% load at 80VAC 80 275 VAC Input Frequency Sine wave 47 63 Hz 100VAC, full load 0.7 Input Current 240VAC, full load 0.4 A 100VAC, full load, 25°C, cold start 50 Inrush Current 240VAC, full load, 25°C, cold start 100 A No Load Power Consumption 230VAC, no load See Table OUTPUT SPECIFICATIONS Output Voltage See Table Line Regulation See Note 4 0.5 1 % Total Regulation See Note 5 See Table Output Power See Table Output Current See Table Ripple & Noise (peak to peak) See Note 6 See Table Hold-up Time See Note 7 12 ms Start-up Time 100~240VAC, full load 3 s Transient Response Time 110VAC, Full load 4 ms Temperature Coefficient -0.04 +0.04 %/°C PROTECTION Short Circuit Protection Auto-recovery Over Load Protection Recovers automatically after fault condition is removed 110 150 % GENERAL SPECIFICATIONS Efficiency Nominal line and rated load See Table Dielectric Withstanding Voltage Primary to Secondary, limit current <10mA 5656 VDC Protection Classes Double insulated, Class II ENVIRONMENTAL SPECIFICATIONS Operating Temperature Derating linearly from 100% Load at 40°C to 50% load at 70°C -10 +70 °C Storage Temperature 10~95% RH -40 +85 °C Operating Humidity Non-condensing 0 95 %RH Storage Humidity 0 95 %RH Cooling Free air convection Flammability Rating UL94V-1 Vibration 10~500Hz, 10min./1cycle, 60 min each along X, Y, Z axes 5 G Operating Altitude (Elevation) 3000 m MTBF MIL-HDBK-217F, 25°C 100,000 hours PHYSICAL SPECIFICATIONS Weight 7.05oz (200g) “U” suffix United States “K” suffix United Kingdom “E” suffix Europe AC Plug “A” suffix Australia Output Connector Several options available SAFETY, EMC, & COMPLIANCE ANSI/AAMI ES 60601-1:2005 (UL/cUL 3rd ed.) IEC60601-1 3rd edition Safety Approvals CE EMC Emission Compliance to EN55011 (CISPR11), EN61000-3-2,-3 B Class Surge Voltage 2 kV Air Discharge, IEC61000-4-2 8 Electro Static Discharge Contact Discharge, IEC61000-4-2 6 kV Compliance RoHS Compliant CEC & Energy Star CEC and Energy Star 2.0, Efficiency Level V
Wall Industries, Inc. Rev B WMIHPU25 SERIES Up to 25 Watts, Medical AC/DC Wall Mount Power Supplies 08/04/2014 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 3 of 4 DERATING Input Voltage Derating Curve Temperature Derating Curve 80 100 120 140 160 180 200 220 240 260 280 110 100 Input Voltage (VAC) Load (%) -10 0 10 20 30 40 50 60 70 80 110 100 Temperature (°C) Load (%) MECHANICAL DRAWING United States Type (Suffix “U”) Europe Type (Suffix “E”) United Kingdom Type (Suffix “K”) AustraliaType (Suffix “A”) NOTES: 1. Unit: inches [mm] 2. Tolerance: ±0.04 [±1.0] 3. Weight: 7.05oz (200g) 4. Models WMIHPU25-101~104 need to use AWG#18 2C/4FT output cable in order to meet the total regulation specified. Models WMIHPU25-105~109 need to use AWG#20 2C/4FT output cable in order to meet the total regulation specified. Models WMIHPU25-110~112 need to use AWG#22 2C/4FT output cable in order to meet the total regulation specified. The technical specifications will change if a different output cable is used. 5. Plugs are sold separately. Please call factory for ordering details. 6. Optional output connectors available. Please call factory for ordering details. 7. All dimensions are for reference only. 2.95 [75.0] 1.71 [43.5] 1.58 [40.2] OPTIONAL R5.0 R2.5
Wall Industries, Inc. Rev B WMIHPU25 SERIES Up to 25 Watts, Medical AC/DC Wall Mount Power Supplies 08/04/2014 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 4 of 4 COMPANY INFORMATION Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well-documented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: (603)778-2300 Toll Free: (888)597-9255 E-mail: sales@wallindustries.com Web: www.wallindustries.com Address: 37 Industrial Drive Exeter, NH 03833