Features

■ Gain-flattened spectral response ■ High saturation output power, > 22 dBm ■ Low power consumption, < 12 W @ 45 °C ■ Low noise ■ Single 5 V operation ■ Wide input signal bandwidth ■ Wide operating temperature range, 0 °C to 65 °C ■ Optical input and output taps ■ Isolated input and output ■ Programmable input and output monitors ■ Connectorized single-mode fiber pigtail ■ Standard serial communication channels

Applications

■ Designed specifically for DWDM applications ■ Booster/power amplifier ■ Line amplifier

Description

The W1724-T ype Erbium-Doped Fiber Amplifier (EDFA) has been designed for use in DWDM applica- tions and offers the following performance features: ■ Flat gain profile over a wide temperature range ■ Low noise figure ■ High output power ■ Automatic gain lock The versatile W1724-T ype EDFA operates over a wide temperature range, exhibits extremely low power dissipation, and offers a variety of alarms and monitors. Optimum performance and system stability are supported through the use of optical isolation at the input and output. Optical input and output are through single-mode fiber pigtails terminated with optical connectors. The EDFA incorporates optical input and output taps that are monitored via an integral microcontroller. Significant performance benefits are achieved with the microcontroller, which stabilizes the temperature of the pumps and maintains constant gain of the amplifier. Contact your Account Manager at Agere Systems Inc. to discuss electrical or optical connector options not listed in the Ordering Information section.

22 Agere Systems Inc. Data Sheet, Rev. 1 Optical Amplifier Platform, 1724-Type September 2001 Erbium-Doped Fiber Amplifier (W Series) Standard Features The standard W1724-Type EDFA incorporates the opti- cal architecture illustrated in Figure 1. The standard features include: ■ Exceptional performance benefits with the integral microcontroller, which precisely controls the gain to maintain a flat spectral response over various input powers. ■ Single 5 V power supply eliminates the need for dual voltage source circuits. ■ DB-25 electrical connector allows for easy electrical connectivity. ■ Optical input tap enables input monitoring and con- trol. ■ SC/PC optical connector. ■ Low power dissipation. ■ Alarms: — Loss of input power alarm. — Loss of output power alarm. — Pump bias alarm (>95% of EOL value). — Pump temperature alarm (T L > 35 °C). — EDFA temperature alarm (TC > 60 °C). ■ Advanced microprocessor design requires minimal engineering for a shelf-level product. ■ Standard mechanical outline includes metric screws and fiber outputs (using SC/PC optical connectors) at 180 degrees relative to a DB25 electrical connec- tor. The standard product does not include a heat sink. TTL-Compatible Alarm Outputs Loss of Input Power Alarm If the input power is more than 2 dBm below the mini- mum P IN, the loss of input power alarm (pin 19) will activate (TTL-logic 1). Loss of Output Power Alarm If the output power decreases by more than 2 dB from its beginning-of-life value, the loss of output power alarm (pin 8) will activate (TTL-logic 1). Pumps Temperature Alarm If the laser temperature for the pump(s) exceeds 35 °C, the pump temperature alarm (pin 10) will activate (TTL- logic 1). Pumps Bias Alarm If the bias current for the pump(s) exceeds 95% of its EOL value, the pump bias alarm (pin 9) will activate (TTL-logic 1). EDFA Temperature Alarm If the case temperature exceeds 60 °C, then the EDFA temperature alarm (pin 7) will activate (TTL- logic 1). Optional Features Other feature and package options for the W1724-T ype EDFA include: ■ Alternative optical connectors ■ Integral heat sink

Figure 1. W1724-Type EDFA Block Diagram

  1. Do not connect to reserved pins.
  2. Normal = TTL low, alarm = TTL high if the output power falls 2 dB below the minimum value.
  3. Normal = TTL low, alarm = TTL high if pump bias exceeds 95% of its end-of-life value.
  4. Normal = TTL low, alarm = TTL high if pump temperature exceeds 35 °C.
  5. The EDFA is equipped with an optical transient suppression feature when this pin is tied to GND. The EDFA will turn all pumps off, if the

the amplifier is turned on without the presence of an optical signal.

  1. Normal = TTL low, alarm = TTL high if input power is less than 2 dB below minimum P
  2. Amplifier enable (all pumps are on) = TTL low, amplifier disable (all pumps are off) = TTL high.

Table 1. Pin Descriptions for a Microcontrolled (Full) Amplifier

5 Reserved

6 Reserved 1 19 Loss of Input Power Alarm 6

7 EDFA T emperature Alarm 20 Reserved 1

8 Loss of Output Power Alarm 2 21 Amplifier Disable Input 7

9 Pumps Bias Alarm 3 22 RS-232 IN (TTL)

10 Pumps T emperature Alarm 4 23 Reserved 1

13 GND — —

4 Agere Systems Inc. Data Sheet, Rev. 1 Optical Amplifier Platform, 1724-Type September 2001 Erbium-Doped Fiber Amplifier (W Series) Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso- lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.

Electrical Characteristics

Table 2. Power Supply

  • Typical operating characteristics: VPS1 = 5.0 V , TC = 35 °C.

Table 3. TTL Inputs/Outputs is outside a predesignated range, the associated alarms will become TTL level high.

Table 4. Performance Specifications for W Series

6 Agere Systems Inc. Data Sheet, Rev. 1 Optical Amplifier Platform, 1724-Type September 2001 Erbium-Doped Fiber Amplifier (W Series) Outline Drawings W1724-Type EDFA Package Dimensions are in inches and (millimeters). 0.44 (11.2) DB 25 CONNECTOR MALE ESD LABEL PIN 1 0.12 4.660 0.415.074MOUNTING HOLES DANGER LABELS AS 0.90 (22.9) 3.10 (78.7) 5.90 (149.9) HEATSINK MOUNTING HOLES M3 x 0.5, 4.5 mm DEEP

5 PLACES

0.165 (4.19) 4.57 (116.08) 4.90 (124.5) 2.285 (58.04) 5.570 (141.48) 3.795 (96.39) 0.17 (4.2) 0.76 (19.3) 0.83 (21.1) 0.03 (0.8) INFORMATION LABEL (118.36) LABEL (10.4)(128.88) (3.0) M3 x 0.5, 5 mm DEEP

4 PLACES

1-997(F)

7Agere Systems Inc. Optical Amplifier Platform, 1724-Type Data Sheet, Rev. 1 Erbium-Doped Fiber Amplifier (W Series) September 2001 Outline Drawings (continued) Optional Package Configuration: W1724-Type EDFA Package with Integral Heat Sink Dimensions are in inches and (millimeters). 0.123 (3.12) 0.38 (9.5) CUSTOMER LABEL LASER WARNING LABEL 1.500 (38.10) 0.033 (0.84) 4.660 (118.36) 0.41 (10.5) 5.90 (149.9) 5.074 (128.88) 3.94 (100.1) 0.98 (24.8) MOUNTING HOLES M3 x 0.5, 5 mm DEEP AS NOTED BY DIMPLE Breinigsville, Pennsylvania USA DATE MANUFACTURED: NOVEMBER 1997 0.76 (19.3) 1.850 (46.99) 1.53 (38.9) 4.91 (124.7) 0.44 (11.2) DB 25 CONNECTOR (MALE) PIN 1 DANGER 1-998(C)

8 Agere Systems Inc. Data Sheet, Rev. 1 Optical Amplifier Platform, 1724-Type September 2001 Erbium-Doped Fiber Amplifier (W Series)

Ordering Information

Table 5. Ordering Information* Table 6. Related Product Information

9Agere Systems Inc. Optical Amplifier Platform, 1724-Type Data Sheet, Rev. 1 Erbium-Doped Fiber Amplifier (W Series) September 2001 Laser Safety Information FDA/CDRH Class IIIb and IEC ® 60825 Class 3B laser product. All versions of the product are FDA/CDRH Class IIIb laser products. The product complies with the U.S. Code of Federal Regulations (CFR), Title 21, Part 1040.10 and 1040.11 laser product regulations.The product is registered/ certified with the FDA under accession number 9320325. All versions are Class 3B laser products per IEC 60825-1:1993. Optical Specifications Optical fiber: single-mode, 8.8 µm/125 µm (mode field/cladding diameter) pigtail with connector. Nominal wavelength: 1550 nm. Absolute maximum output power: <500 mW. Product is not shipped with power supply. CAUTION: Use of controls, adjustments, and procedures other than those specified herein may result in hazardous laser radiation exposure. INVISIBLE LASER RADIATION EMITTED FROM END OF FIBER OR CONNECTOR Avoid exposure to beam Class 3B Laser Product IEC-60825 1993 Max. Output: 500 mW Wavelength: 1.55 µm LASER APERTURE DANGER INVISIBLE LASER RADIATION AVOID DIRECT EXPOSURE TO BEAM Max. Out put: 500 mW, Wavelen gth: 1.5 µm Class IIIb Laser Product DANGER INVISIBLE LASER RADIATION IS EMITTED FROM THE END OF FIBER OR CONNECTOR Avoid direct exposure to beam Do not view beam directly with optical instruments

Data Sheet, Rev. 1 Optical Amplifier Platform, 1724-Type September 2001 Erbium-Doped Fiber Amplifier (W Series) Agere Systems Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. Copyright © 2001 Agere Systems Inc. All Rights Reserved September 2001 DS00-123OPTO-1 (Replaces DS00-123OPTO) For additional information, contact your Agere Systems Account Manager or the following: INTERNET: http://www.agere.com E-MAIL: docmaster@agere.com N. AMERICA: Agere Systems Inc., 555 Union Boulevard, Room 30L-15P-BA, Allentown, P A 18109-3286 1-800-372-2447, FAX 610-712-4106 (In CANADA: 1-800-553-2448, FAX 610-712-4106) ASIA: Agere Systems Hong Kong Ltd., Suites 3201 & 3210-12, 32/F , T ower 2, The Gateway, Harbour City, Kowloon Tel. (852) 3129-2000, FAX (852) 3129-2020 CHINA: (86) 21-5047-1212 (Shanghai), (86) 10-6522-5566 (Beijing), (86) 755-695-7224 (Shenzhen) JAPAN: (81) 3-5421-1600 (T okyo), KOREA: (82) 2-767-1850 (Seoul), SINGAPORE: (65) 778-8833, T AIWAN: (886) 2-2725-5858 (Taipei) EUROPE: Tel. (44) 7000 624624, FAX (44) 1344 488 045 IEC is a registered trademark of the International Electrotechnical Commission.