Features
(=VOUT x10) Output Current Designator (=IOUT) Part Numbering Voltage Transformation Module Input Voltage Designator Package Size Pin Style P = Through hole Size: 1.91 x 1.09 x 0.37 in 48,6 x 27,7 x 9,5 mm
Voltage Transformation Module VT048A060T040FP vicorpower.com Rev. 1.0 Page 2 of 11 Parameter Values Unit Notes +In to -In -1.0 to 60 Vdc +In to -In 100 Vdc For 100 ms PC to -In -0.3 to 7.0 Vdc VC to -In -0.3 to 19.0 Vdc +Out to -Out -0.5 to 12 Vdc Isolation voltage 2,250 Vdc Input to output Output current 40 A Continuous Peak output current 60.0 A For 1 ms Output power 264 W Continuous Peak output power 397 W For 1 ms Operating temperature -40 to +100 °C T-Grade; baseplate -55 to +100 °C M-Grade ; baseplate Storage temperature -40 to +125 °C T-Grade -65 to +125 °C M-Grade Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Absolute Maximum Ratings SPECIFICATIONS Parameter Min Typ Max Unit Notes Input voltage range 26 48 55 Vdc Max V IN = 53 V, operating from -55°C to -40°C Input dV/dt 1 V/µs Input overvoltage turn-on 55.0 Vdc Input overvoltage turn-off 59.3 Vdc Input current 5.5 Adc Input reflected ripple current 275 mA p-p Using test circuit in Figure 10; See Figure 1 No load power dissipation 2.7 3.50 W Internal input capacitance 1.9 µF Internal input inductance 5 nH Input Specifications (Conditions are at 48 Vin, full load, and 25°C ambient unless otherwise specified) Note: Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any other conditions in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability.
Voltage Transformation Module VT048A060T040FP vicorpower.com Rev. 1.0 Page 5 of 11 SPECIFICATIONS (CONT.) Parameter Min Typ Max Unit Notes MTBF MIL-HDBK-217F 3.5 Mhrs 25°C, GB Isolation specifications Voltage 2,250 Vdc Input to output Capacitance 3,000 pF Input to output Resistance 10 M Ω Input to output Agency approvals cTÜVus UL/CSA 60950-1, EN 60950-1 CE Mark Low voltage directive RoHS Mechanical See Mechanical Drawings, Figures 15, 16 Weight 1.10/31.3 oz /g Dimensions Length 1.91/48,6 in /mm Baseplate model Width 1.09/27,7 in /mm Baseplate model Height 0.37/9,5 in /mm Baseplate model Thermal Over temperature shutdown 125 130 135 °C Junction temperature Thermal capacity 23.8 Ws /°C Baseplate-to-ambient 7.7 °C /W Baseplate-to-ambient; 1000 LFM 2.9 °C /W Baseplate-to-sink; flat, greased surface 0.40 °C /W Baseplate-to-sink; thermal pad 0.36 °C /W General Specifications Parameter Min Typ Max Unit Notes Primary Control (PC) DC voltage 4.8 5.0 5.2 Vdc Module disable voltage 2.4 2.5 Vdc Module enable voltage 2.5 2.6 Vdc VC voltage must be applied when module is enabled using PC Current limit 2.4 2.5 2.9 mA Source only Disable delay time 10 µs PC low to Vout low VTM Control (VC) External boost voltage 12 14 19 Vdc Required for VTM start up without PRM External boost duration 10 ms Vin > 26 Vdc. VC must be applied continuously if Vin < 26 Vdc. Auxiliary Pins
Voltage Transformation Module VT048A060T040FP vicorpower.com Rev. 1.0 Page 6 of 11 +In / -In DC Voltage Ports The VTM input should not exceed the maximum specified. Be aware of this limit in applications where the VTM is being driven above its nominal out- put voltage. If less than 26 Vdc is present at the +In and -In ports, a contin- uous VC voltage must be applied for the VTM to process power. Otherwise VC voltage need only be applied for 10 ms after the voltage at the +In and -In ports has reached or exceeded 26 Vdc. If the input voltage exceeds the overvoltage turn-off, the VTM will shutdown. The VTM does not have internal input reverse polarity protection. Adding a properly sized diode in series with the positive input or a fused reverse-shunt diode will provide reverse polarity protection. TM – For Factory Use Only VC – VTM Control The VC port is multiplexed. It receives the initial VCC voltage from an upstream PRM, synchronizing the output rise of the VTM with the output rise of the PRM. Additionally, the VC port provides feedback to the PRM to compensate for the VTM output resistance. In typical applications using VTMs powered from PRMs, the PRM’s VC port should be connected to the VTM VC port. In applications where a VTM is being used without a PRM, 14 V must be supplied to the VC port for as long as the input voltage is below 26 V and for 10 ms after the input voltage has reached or exceeded 26 V. The VTM is not designed for extended operation below 26 V. The VC port shouldonly be used to provide V CC voltage to the VTM during startup. PC – Primary Control The Primary Control (PC) port is a multifunction port for controlling the VTM as follows: Disable – If PC is left floating, the VTM output is enabled. To disable the output, the PC port must be pulled lower than 2.4 V, referenced to -In. Optocouplers, open collector transistors or relays can be used to control the PC port. Once disabled, 14 V must be re-applied to the VC port to restart the VTM. Primary Auxiliary Supply – The PC port can source up to 2.4 mA at 5 Vdc. +Out / -Out DC Voltage Output Ports The output and output return are through two sets of contact locations. The respective +Out and –Out groups must be connected in parallel with as low an interconnect resistance as possible. Within the specified input voltage range, the Level 1 DC behavioral model shown in Figure 13 defines the output voltage of the VTM. The current source capability of the VTM is shown in the specification table. To take full advantage of the VTM, the user should note the low output impedance of the device. The low output impedance provides fast tran- sient response without the need for bulk POL capacitance. Limited-life electrolytic capacitors required with conventional converters can be reduced or even eliminated, saving cost and valuable board real estate. PIN / CONTROL FUNCTIONS Figure 9 — VI BRICK VTM pin configuration (viewed from pin side)
Voltage Transformation Module VT048A060T040FP vicorpower.com Rev. 1.0 Page 7 of 11 APPLICATION NOTES & TEST CIRCUIT Parallel Operation In applications requiring higher current or redundancy, VTMs can be operated in parallel without adding control circuitry or signal lines. To maximize current sharing accuracy, it is imperative that the source and load impedance on each VTM in a parallel array be equal. If VTMs are being fed by an upstream PRM, the VC nodes of all VTMs must be con- nected to the PRM VC. To achieve matched impedances, dedicated power planes within the PC board should be used for the output and output return paths to the array of paralleled VTMs. This technique is preferable to using traces of varying size and length. The VTM power train and control architecture allow bi-directional power transfer when the VTM is operating within its specified ranges. Bi-direc- tional power processing improves transient response in the event of an output load dump. The VTM may operate in reverse, returning output power back to the input source. It does so efficiently. Input Impedance Recommendations To take full advantage of the VTM’s capabilities, the impedance of the source (input source plus the PC board impedance) must be low over a range from DC to 5 MHz. The input of the VTM (factorized bus) should be locally bypassed with a 8 µF low Q aluminum electrolytic capacitor. Additional input capacitance may be added to improve transient performance or compensate for high source impedance. The VTM has extremely wide bandwidth so the source response to transients is usually the limiting factor in overall output response of the VTM. Anomalies in the response of the source will appear at the output of the VTM, multiplied by its K factor of 1/8 . The DC resistance of the source should be kept as low as possible to minimize voltage deviations on the input to the VTM. If the VTM is going to be operating close to the high limit of its input range, make sure input voltage deviations will not trig- ger the input overvoltage turn-off threshold. Input Fuse Recommendations VI BRICKs are not internally fused in order to provide flexibility in config- uring power systems. However, input line fusing of VI BRICKs must always be incorporated within the power system. A fast acting fuse is required to meet safety agency Conditions of Acceptability. The input line fuse should be placed in series with the +In port. For agency approvals and fusing conditions, click on the link below: http://www.vicorpower.com/technical_library/technical_documentation/quality_ and_certification/safety_approvals/ Application Notes For VTM and VI BRICK application notes on soldering, board layout, and system design please click on the link below: http://www.vicorpower.com/technical_library/application_information/ Applications Assistance Please contact Vicor Applications Engineering for assistance, 1-800-927-9474, or email at apps@vicorpower.com. Load Input reflected ripple measurement point 0.47 μF ceramic +–14 V VTM +IN +OUT -OUT +OUT -OUT-IN TM VC PC Figure 10 — VI BRICK VTM test circuit Notes: 1. C3 should be placed close to the load 2. R3 may be ESR of C3 or a separate damping resistor. [a] See Input Fuse Recommendations section 10 µF 10 mΩC1 47 µF Al electrolytic 7A [a] Fuse
Voltage Transformation Module VT048A060T040FP vicorpower.com Rev. 1.0 3/08 Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: custserv@vicorpower.com Technical Support: apps@vicorpower.com Warranty Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only. EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty. Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function, or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor against all damages. Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intel- lectual Property Department. The products described on this data sheet are protected by the following U.S. Patents Numbers: 7,145,186; 7,166,898; 7,187,263; 7,202,646; 7,361,844; D496,906; D505,114; D506,438; D509,472; and for