VN3 TIMOTION | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 6

Technical content

The VN3 series linear actuator is specifically designed for ventilation applications to help quickly remove smoke, heat, and toxic gases from buildings in the event of a fire. It is also engineered to support a reduced smoke layer in the lower parts of a room. The VN3 is constructed with high- quality aluminum, making it ideal for applications like fall-through protection systems and greenhouses. The VN3 has a higher load capacity than the VN2, and is currently equipped with either a 12V or 24V DC motor. General Features Max. load 3,000N (push/pull) Max. speed at max. load 3.5mm/s Max. speed at no load 6.8mm/s Retracted length ≥ Stroke + 248mm IP rating IP66 Stroke 20~500mm Output signals Hall sensors Options Safety nut Voltage 12/24V DC; 12/24V DC (thermal switch) Operational temperature range -20°C~+65°C Operational temperature range +5°C~+45°C at full performance Product Segments

  • Industrial Motion

(mm) Drawing Load and Speed CODE Load (N) Self Locking Force (N) Typical Current (A) Typical Speed (mm/s) Push Pull No Load 24V DC With Load 24V DC No Load 24V DC With Load 24V DC Motor Speed (5600RPM, Duty Cycle 10%) B 3000 3000 3000 ≤0.4 ≤3.2 6.8 3.5 CODE Load (N) Max Stroke (mm) B 3000 500 Note 1 Please refer to the approved drawing for the final authentic value. 2 This self-locking force level is reached only when a short circuit is applied on the terminals of the motor. All the TiMOTION control boxes have this feature built-in. 3 The current & speed in table are tested with 24V DC motor. With a 12V DC motor, the current is approximately twice the current measured in 24V DC; speed will be similar for both voltages. 4 The current & speed in table are tested when the actuator is extending under push load. 5 The current & speed in table and diagram are tested with a stable 24V DC power supply.

6 Without load, noise level ≤ 65dBA (by TiMOTION test standard, background noise level ≤ 36dBA)

7 Standard stroke: Min. ≥ 20mm, Max. please refer to below table. Retracted Length 6.2 ø22 ø22.1 27 .6 ø10.2 ø10.2 6.2 4313

Motor Speed (5600RPM, Duty Cycle 10%) Performance Data (24V DC Motor) VN3 series B 1.0 0.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 0 1000 2000 3000 4000 5000 Speed (mm/s) Speed vs. Load Load (N) B 1.0 0.0 2.0 3.0 4.0 0 1000 2000 3000 4000 5000 Current (A) Current vs. Load Load (N)

Cable Length (mm) IP Rating Connector See page 6 Color Direction of Rear Attachment (Counterclockwise) 1 = 12V DC 2 = 24V DC 3 = 12V DC, thermal switch 4 = 24V DC, thermal switch 0 = Without (Option when choosing rear attachment #1, #2, #3) 0 = Without (Option when choosing rear attachment #1, #2, #3) 0 = Without 2 = Hall sensor * 2 0 = Standard 1 = Without 2 = IP54 3 = IP66 2 = 0° Stroke (mm) Retracted Length (mm) See page 2 See page 5 See page 2 Rear Attachment (mm) See page 6 Front Attachment (mm) See page 6 1 = Aluminum, U clevis, slot 6.2, depth 13, hole 6.2 2 = Aluminum, U clevis, slot 6.2, depth 13, hole 8.2 3 = Aluminum, U clevis, slot 6.2, depth 13, hole10.2 1 = Aluminum, U clevis, slot 6.2, depth 17, hole 6.2 2 = Aluminum, U clevis, slot 6.2, depth 17, hole 8.2 3 = Aluminum, U clevis, slot 6.2, depth 17, hole10.2 Function of Limit Switches 1 = Two micro switches cut off the actuator at end of stroke 3 = Two micro switches send signal at end of stroke Special Function of Spindle Subassembly 0 = Without (Standard) 1 = Safety nut 1 = DIN 6P , 90° plug 2 = Tinned leads 0 = Without 1 = 500 2 = 1000 3 = 1500 4 = 2000 5 = 5000 Version: 20231206-E Output Signal See page 6

  1. Calculate A+B = Y 2. Retracted length needs to ≥ Stroke+Y Retracted Length (mm) Front Attach. Rear Attach. 1, 2, 3 1, 2, 3 +248 Stroke (mm) Load (N) 20~150 - 151~200 - 201~250 +5 251~300 +10 301~350 +15 351~400 +20 401~450 +25 451~500 +30

1 = Aluminum, U clevis, slot 6.2, depth 13, hole 6.2 2 = Aluminum, U clevis, slot 6.2, depth 13, hole 8.2 3 = Aluminum, U clevis, slot 6.2, depth 13, hole10.2 Rear Attachment (mm) 1 = Aluminum, U clevis, slot 6.2, depth 17, hole 6.2 2 = Aluminum, U clevis, slot 6.2, depth 17, hole 8.2 3 = Aluminum, U clevis, slot 6.2, depth 17, hole10.2 Front Attachment (mm) ø6.2 6.2 ø22 ø6.2 8.2 ø22 ø6.2 10.2 ø22 ø6.26.2 ø8.26.2 ø10.26.2 Wiring Definition Signal Output Pin / Color Green Red White Black Yellow Blue

0 Without Extend+ - - - Retract+ -

2 Hall sensor Extend+ VCC (5V DC) Hall 1 Com Retract+ Hall 2

The user is responsible for determining the suitability of TiMOTION products for a specific application. TiMOTION products are subject to change without prior notice. Connector 1 = DIN 6P , 90° plug 2 = Tinned leads