- Industrial Motion VN2 series The VN2 series linear actuator is designed specifically for ventilation applications to help remove smoke, heat, and toxic gases from buildings quickly in the event of a fire. It is also designed to generate a minimum smoke layer in the lower parts of a room. The VN2 is made of high-quality aluminum, suitable for applications like fall-through protection systems and greenhouses. The VN2 is currently equipped with either a 12V or 24V DC motor. General Features Max. load 500N (push / pull) Max. speed at max. load 8.35mm/s Max. speed at no load 10.8mm/s Retracted length ≥ Stroke + 189mm IP rating IP66 Stroke 20~500mm Output signals Hall sensors Voltage 12/24V DC; 12/24V DC (thermal switch) Operational temperature range -25°C~+65°C Operational temperature range +5°C~+45°C at full performance
(mm) Load and Speed CODE Load (N) Self Locking Force (N) Typical Current (A) Typical Speed (mm/s) Push Pull No Load 32V DC With Load 24V DC No Load 32V DC With Load 24V DC Motor Speed (5200RPM, Duty Cycle 20%:2min on/8min off) B 500 500 500 0.7 1.3 10.8 8.35 Note 1 Please refer to the approved drawing for the final authentic value. 2 This self-locking force level is reached only when a short circuit is applied on the terminals of the motor. All the TiMOTION control boxes have this feature built-in. 3 The current & speed in table are tested with 24V DC motor. With a 12V DC motor, the current is approximately twice the current measured in 24V DC; speed will be similar for both voltages. 4 The current & speed in table are tested when the actuator is extending under push load. 5 The current & speed in table and diagram are tested with a stable 24V DC power supply. 6 Standard stroke: Min. ≥ 20mm, Max. please refer to below table. CODE Load (N) Max Stroke (mm) B ≤ 500 500 Retracted Length ø6.2 ø6.2 4112.512.5 1 7. 6 6.2 6.2
Motor Speed (5200RPM, Duty Cycle 20%:2min on/8min off) Performance Data (24V DC Motor) B 0.0 2.0 4.0 6.0 8.0 10.0 12.0 0 200 500400100 300 600 Speed (mm/s) Speed vs. Load Load (N) 0.0 1.4 0.4 0.6 0.8 1.0 0.2 1.2 0 200100 400 500300 600 B Current (A) Current vs. Load Load (N)
(Counterclockwise) 1 = 12V DC 2 = 24V DC 3 = 12V DC, thermal switch 4 = 24V DC, thermal switch 0 = Standard 0 = Without (Option when choosing rear attachment #1, #2, #3, #4) 0 = Without (Option when choosing rear attachment #1, #2, #3, #4) 2 = 0° Stroke (mm) Retracted Length (mm) See page 2 See page 5 See page 2 Rear Attachment (mm) See page 6 Front Attachment (mm) See page 6 1 = Plastic, slotless, hole 6.2 2 = Plastic, slotless, hole 8.2 3 = Plastic, U clevis, slot 6.2, depth 12.5, hole 6.2 4 = Plastic, U clevis, slot 6.2, depth 12.5, hole 8.2 IP Rating 1 = Without 2 = IP54 3 = IP66 1 = DIN 6P , 90°plug 2 = Tinned leads C = Y cable (direct cut, water proof, anti-pull) Function of Limit Switches See page 6 Connector See page 7 1 = Two micro switches cut off the actuator at end of stroke 3 = Two micro switches send signal at end of stroke Special Function of Spindle Set 0 = Without Cable Length (mm) Output Signal 0 = Without 1 = 500 2 = 1000 3 = 1500 4 = 2000 5 = 5000 B~H = Cable length for direct cut system, See page 7 0 = Without 2 = Hall sensor * 2 1 = Aluminum, slotless, hole 6.2 2 = Aluminum, slotless, hole 8.2 3 = Plastic, U clevis, slot 6.2, depth 12.5, hole 6.2 4 = Plastic, U clevis, slot 6.2, depth 12.5, hole 8.2 5 = Plastic, U clevis, slot 6.2, depth 22.5, hole 8.2 Version: 20230309-H
- Calculate A+B = Y 2. Retracted length needs to ≥ Stroke+Y Retracted Length (mm) Stroke (mm) 20~150 - 151~200 +2 201~250 +2 251~300 +2 301~350 +12 351~400 +22 401~450 +32 451~500 +42 Front Attach. Rear Attach. 1, 2, 3, 4 1, 2 +189 3, 4 +200 5 +210
Rear Attachment (mm) 1 = Plastic, slotless, hole 6.2 2 = Plastic, slotless, hole 8.2 3 = Plastic, U clevis, slot 6.2, depth 12.5, hole 6.2 4 = Plastic, U clevis, slot 6.2, depth 12.5, hole 8.2 ø6.2 ø16 12.5 1 7. 6 6.2 ø8.2 ø16 12.5 1 7. 6 6.2 ø6.2 ø16 1 7. 6 ø8.2 ø16 1 7. 6 Front Attachment (mm) 1 = Aluminum, slotless, hole 6.2 2 = Aluminum, slotless, hole 8.2 3 = Plastic, U clevis, slot 6.2, depth 12.5, hole 6.2 5 = Plastic, U clevis, slot 6.2, depth 22.5, hole 8.2 4 = Plastic, U clevis, slot 6.2, depth 12.5, hole 8.2 Functions for Limit Switches Wire Definitions CODE Pin 1 (Green) 2 (Red) 3 (White) 4 (Black) 5 (Yellow) 6 (Blue) 1 extend (VDC+) N/A N/A N/A retract (VDC+) N/A 3 extend (VDC+) common upper limit switch N/A retract (VDC+) lower limit switch ø6.2 ø50 12.5 6.2 ø8.2 ø50 12.5 6.2 ø6.2 ø19.9 ø8.2 ø19.9 ø8.2 ø50 22.58.6 6.2
The user is responsible for determining the suitability of TiMOTION products for a specific application. TiMOTION products are subject to change without prior notice. 1 = DIN 6P , 90° plug 2 = Tinned leads Connector Cable Length for Direct Cut System (mm) CODE L1 L2 L3 B 100 100 100 C 100 1000 400 D 100 2700 500 E 1000 100 100 F 100 600 1000 G 1500 1000 1000 H 100 100 1200 C = Y cable (direct cut, water proof, anti-pull) L2 L1