VEB10US05 XPPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

  • Energy Efficiency Level V
  • CEC2008 & EISA2007 Compliant
  • +70 °C Operating Temperature
  • Universal Input
  • Output Voltages from 5.0 V to 48.0 V Available
  • Class II Construction
  • Low Cost Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • 0.3 A max at 90 VAC Inrush Current • 80 A max at 240 VAC, cold start at 25 °C Power Factor • EN61000-3-2, class A No Load Input Power • <0.3 W Input Protection • Internal T1.0A/250 V fuse in line Output Output Voltage • See table Minimum Load • No minimum load required Start Up Delay • 3 s max Start Up Rise Time • 100 ms typical Hold Up Time • 5 ms typical at full load and 100 VAC Total Regulation • See table Transient Response • 4% max. deviation, recovery to <1% within 500 µs for a 50% step load change at 0.2 A/µs Ripple & Noise • 1.0% pk-pk max, 20 MHz bandwidth Overvoltage Protection• Not fitted Overload Protection • 120-280%, auto recovery Short Circuit Protection• Trip and restart (hiccup mode) Temperature • 0.04 %/°C Coefficient General Efficiency • See table Energy Efficiency • Level V Isolation • 3000 VAC Input to Output Switching Frequency • 80 kHz typical MTBF • >330 kHrs per MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature• 0 °C to +70 °C, derate linearly from 100% load at 40 °C to 50% load at 70 °C Cooling • Natural convection Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -40 °C to +85 °C Shock • Able to survive 1 m drop onto concrete on each of 6 axes Vibration • 10-300 Hz, 2 g 15 mins/sweep, 30 mins for each of 3 axes EMC & Safety Emissions • EN55022, level B conducted & radiated Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, ±4 kV contact, ±8 kV air, Perf Criteria A Radiated Immunity • EN61000-4-3, 3 V/m, Perf Criteria A EFT/Burst • EN61000-4-4, level 2, Perf Criteria A Surge • EN61000-4-5, installation class 3, Perf Criteria A Conducted Immunity • EN61000-4-6, 3 V, Perf Criteria A Magnetic Field • EN61000-4-8, 1 A/m, Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals • EN60950-1 for EU and UK models UL60950-1 for US models AC-DC B R A N D

10 Watts

Output Power Output Voltage(1) Output Current Total Regulation(2) Efficiency(4) Model Number (3) 8 W 5.0 V 1.60 A 5% 73% VEB10US05 10 W 9.0 V 1.11 A 5% 77% VEB10US09 10 W 12.0 V 0.83 A 5% 78% VEB10US12 10 W 15.0 V 0.66 A 5% 77% VEB10US15 10 W 24.0 V 0.42 A 5% 77% VEB10US24 10 W 48.0 V 0.21 A 5% 80% VEB10US48 1. Other output voltages available, contact sales for details. 2. Total regulation includes initial set accuracy, line and load regulation. 3. Add suffix to model number to define input plug type, add ‘-US’ for US plug, ‘-UK’ for UK plug or ‘-EU for European plug. 4. Average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input. Mechanical Details Notes -US Version -UK Version -EU Version Notes 1. All dimensions are in inches (mm). Tolerance is ±0.04 (±1.0), except output cable length is +4, -0 (+100, -0) 2. Weight: US Version 70 g, EU Version 70 g, UK Version 90 g 1.73 (44.0) 2.32 (59.0) 1.36 (34.7) 48.0 (1220) 20 AWG for 5-12 V, 48 (1220) 24 AWG for 15-48 V To order add ‘-UK’ to model number 0.047 (1.2) 1.73 (44.0) 2.32 (59.0) 1.73 (44.0) 2.32 (59.0) To order add ‘-EU’ to model numberTo order add ‘-US’ to model number 0.67(17.2) 0.40 (10.3) VEB10