15 Watts
- CEC 2008 & EISA 2007 Compliant
- Approved as LPS
- China Compulsory Certfication (CCC) Qualified
- High Efficiency
- +70 °C Operating Temperature
- Compact Dimensions
- Optional Input Connector AEL Series Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • 0.4 A at 115 VAC Inrush Current • 15 A/30 A for 115 VAC/230 VAC, cold start Earth Leakage Current• 0.75 mA at 240 VAC Power Factor • Meets EN61000-3-2 Input Protection • Fitted with internal fuse Standby Power • Typically 0.3 W, max 0.5 W Consumption Output Output Voltage • See tables Minimum Load • No minimum load required Hold Up Time • 5 ms min at full load 110 VAC Start Up Delay • 2.0 s at full load 100 VAC Transient Response • 2% deviation, recovery to within 1% of nominal in 4 ms for 50% load change Line Regulation • See tables Load Regulation • See tables Ripple & Noise • 1% pk-pk max, 20 MHz BW. See note 3. Short Circuit Protection• Trip & restart (Hiccup mode), auto recovery Temperature • ±0.04%/°C Coefficient xppower.com General Efficiency • 85% typical Isolation • 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
Switching Frequency • 63 kHz typical MTBF • 300 kHrs to MIL-STD-217F Environmental Operating Temperature• 0 °C to +70 °C, derate from 100% power at +40 °C to 50% power at +70 °C Storage Temperature • -40 °C to +85 °C Cooling • Convection cooled Operating Humidity • 5-95% RH, non-condensing Operating Altitude • 3000 m Shock • 10 g, 10 ms on 3 axes Vibration • 5-100 Hz 2.31 m/s2, 20 mins 3 axes EMC & Safety Emissions • EN55022 FCC Part-15C Level B conducted & radiated Harmonic Current • EN61000-3-2 Class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2 Level 3 Perf criteria A Radiated Immunity • EN61000-4-3 3 V/m Perf criteria A EFT/Burst • EN61000-4-4 Level 2 Perf criteria A Surge • EN61000-4-5 Level 3 Perf criteria A Conducted Immunity • EN61000-4-6 Level 2 Perf criteria A Magnetic Field • EN61000-4-8 1 A/m Perf criteria A Dips & Interruptions • EN61000-4-11, 70% U T for 500 ms, 40% U T for 100 ms, <5% UT for 5000 ms Perf criteria A, B, B Safety Approvals • EN60950-1:2001, UL/cUL60950-1, Approved as Limited Power Source, CE Mark, China Compulsory Certification (CCC) qualified.
- Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 3. Measured at 25 ºC 4. Other output voltages available, contact sales for details. Max Output Power Output Voltage(4) Output Current Total Regulation(2) Model Number (1) 8 W 3.3 VDC 2.50 A 7% AEL15US03 12 W 5 VDC 2.40 A 7% AEL15US05 15 W 8 VDC 1.87 A 5% AEL15US08 9 VDC 1.66 A 5% AEL15US09 12 VDC 1.25 A 5% AEL15US12 15 VDC 1.00 A 5% AEL15US15 18 VDC 0.83 A 5% AEL15US18 24 VDC 0.62 A 5% AEL15US24 30 VDC 0.50 A 5% AEL15US30 36 VDC 0.42 A 3% AEL15US36 48 VDC 0.31 A 3% AEL15US48 3. Output cable length is 48” (1220mm) approx. 4. Weight is 0.36 lbs (165 g) 5. For European mains lead order part: EU-MAINS-IEC or EU-MAINS-5 for C6 version. 6. For UK mains lead order part: UK-MAINS-IEC or UK-MAINS-5 for C6 version. 7. For US mains lead order part: US-MAINS-IEC or US-MAINS-5 for C6 version. Notes 1.50 ±0.04 (38.0 ±1.0) 3.58 ±0.04 (91.0 ±1.0) 1.42 ±0.04 (36.0 ±1.0) AC INPUT IEC-320-C14 INLET AC INPUT IEC-320-C6 INLET Mechanical Details
- CEC 2008 & EISA 2007 Compliant
- Approved as LPS
- China Compulsory Certfication (CCC) Qualified
- Up to 88% Efficiency
- +70 °C Operating Temperature
- Compact Dimensions
- 20 W Optional Class II Insulation AEL Series Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • 0.4 A max AEL20
1.0 A max AEL40
1.6 A max AEL60
Inrush Current • 15 A/30 A for 115 VAC/230 VAC, cold start Earth Leakage Current• 0.75 mA at 240 VAC (except C2 version) Power Factor • Meets EN61000-3-2 Input Protection • Fitted with internal fuse,
1 A AEL20, 2 A AEL40/60
Standby Power • Typically 0.3 W, max 0.5 W Consumption Output Output Voltage • See tables Minimum Load • No minimum load required Hold Up Time • 12 ms min AEL20, 16 ms AEL40/60, at full load 110 VAC Start Up Delay • 0.5 s AEL20/40, 2.0 s AEL60, at full load 100 VAC Transient Response • 2% deviation, recovery to within 1% of nominal in 500 µs for 50% load change Line Regulation • See tables Load Regulation • See tables Ripple & Noise • 1% pk-pk max, 20 MHz BW Overvoltage Protection• 112-132% Overload Protection • 110-150% Short Circuit Protection• Trip & restart (Hiccup mode), auto recovery Temperature • ±0.04%/°C Coefficient xppower.com General Efficiency • 85% typical AEL20/40, 88% typical AEL60 Isolation • 3000 VAC Input to Output
1500 VAC Input to Ground (not C2 version)
500 VDC Output to Ground (not C2 version)
Switching Frequency • 63 kHz typical MTBF • 300 kHrs AEL20, 200 kHrs AEL40, 130 kHrs AEL60 to MIL-STD-217F Environmental Operating Temperature• 0 °C to +70 °C, derate from 100% power at +40 °C to 50% power at +70 °C Storage Temperature • -40 °C to +85 °C Cooling • Convection cooled Operating Humidity • 5-95% RH, non-condensing Operating Altitude • 3000 m Shock • 10 g, 10 ms on 3 axes Vibration • 5-100 Hz 2.31 m/s2, 20 mins 3 axes EMC & Safety Emissions • EN55022 FCC Part-15C Level B conducted & radiated Harmonic Current • EN61000-3-2 Class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2 Level 3 Perf criteria A Radiated Immunity • EN61000-4-3 3 V/m Perf criteria A EFT/Burst • EN61000-4-4 Level 2 Perf criteria A Surge • EN61000-4-5 Level 3 Perf criteria A Conducted Immunity • EN61000-4-6 Level 2 Perf criteria A Magnetic Field • EN61000-4-8 1 A/m Perf criteria A Dips & Interruptions • EN61000-4-11, 70% U T for 500 ms, 40% U T for 100 ms, <5% UT for 5000 ms Perf criteria A, B, B Safety Approvals • EN60950-1:2001, UL/cUL60950-1, Approved as Limited Power Source, CE Mark, China Compulsory Certification (CCC) qualified.
- For optional Class II version on AEL20 models only, add suffix ‘C2’ to model number e.g. AEL20US12C2. 2. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 3. Other output voltages available, contact sales for details. Max Output Power Output Voltage(3) Output Current Total Regulation(2) Model Number (1) 15 W 5 VDC 3.00 A 5% AEL20US05 20 W 12 VDC 1.67 A 4% AEL20US12 15 VDC 1.33 A 4% AEL20US15 24 VDC 0.83 A 3% AEL20US24 30 VDC 0.67 A 3% AEL20US30 48 VDC 0.42 A 3% AEL20US48 3. Output cable length is 48” (1220mm) approx. 4. Weight is 0.37 lbs (170 g) 5. For European mains lead order part: EU-MAINS-C5 for AEL20, EU-MAINS-8 for AEL20 Class II. 6. For UK mains lead order part: UK-MAINS-5 for AEL20, UK-MAINS-8 for AEL20 Class II. 7. For US mains lead order part: US-MAINS-5 for AEL20, US-MAINS-8 for AEL20 Class II. Notes 0.04 (1.0) AC INPUT IEC-320-C6 INLET AC INPUT IEC-320-C8 INLET (Optional C2 Version) Mechanical Details
Voltage(2) Output Current Total Regulation(1) Model Number 25 W 5 VDC 5.00 A 7% AEL40US05 35 W 8 VDC 4.37 A 5% AEL40US08 9 VDC 3.88 A 5% AEL40US09 40 W 12 VDC 3.33 A 5% AEL40US12 15 VDC 2.67 A 5% AEL40US15 18 VDC 2.22 A 5% AEL40US18 24 VDC 1.67 A 3% AEL40US24 36 VDC 1.11 A 3% AEL40US36 48 VDC 0.83 A 3% AEL40US48 Notes 1. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 2. Other output voltages available, contact sales for details. 3. Output cable length is 48” (1220mm) approx. 4. Weight is 0.70 lbs (300 g). 5. For European mains lead order part: EU-MAINS-IEC. 6. For UK mains lead order part: UK-MAINS-IEC. 7. For US mains lead order part: US-MAINS-IEC. Notes 4.65 (118.00) 0.02 (0.50) AC INPUT IEC-320-C14 INLET 0.04 (1.0) Mechanical Details
- Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 2. Other output voltages available, contact sales for details. 3. Output cable length is 48” (1220mm) approx. 4. Weight 0.70 lbs (300 g). 5. For European mains lead order part: EU-MAINS-IEC. 6. For UK mains lead order part: UK-MAINS-IEC. 7. For US mains lead order part: US-MAINS-IEC. Notes 4.65 (118.00) 0.02 (0.50) AC INPUT IEC-320-C14 INLET 0.04 (1.0) Mechanical Details Models and Ratings Max Output Power Output Voltage(2) Output Current Total Regulation(1) Model Number 57 W 12 VDC 4.75 A 5% AEL60US12 63 W 15 VDC 4.20 A 5% AEL60US15 18 VDC 3.50 A 5% AEL60US18 24 VDC 2.63 A 5% AEL60US24 30 VDC 2.15 A 5% AEL60US30 36 VDC 1.75 A 3% AEL60US36 48 VDC 1.31 A 3% AEL60US48
80 Watts
- CEC 2008 & EISA 2007 Compliant
- China Compulsory Certfication (CCC) Qualified
- Output Voltages from 12 to 48 VDC
- High Efficiency
- +70 °C Operating Temperature
- Compact Dimensions AEL80 Series Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • 1.1 A max Inrush Current • 15 A/30 A for 115 VAC/230 VAC, cold start Earth Leakage Current• 0.75 mA at 240 VAC Power Factor • Meets EN61000-3-2 Input Protection • Fitted with internal fuse Standby Power • Typically 0.3 W, max 0.5 W Consumption Output Output Voltage • See tables Minimum Load • No minimum load required Hold Up Time • 16 ms min at full load 110 VAC Start Up Delay • 2.0 s at full load 100 VAC Transient Response • 2% deviation, recovery to within 1% of nominal in 500 µs for 50% load change Line Regulation • See tables Load Regulation • See tables Ripple & Noise • 1% pk-pk max, 20 MHz BW Overvoltage Protection• 112-132% Overload Protection • 110-150% Short Circuit Protection• Trip & restart (Hiccup mode), auto recovery Temperature • ±0.04%/°C Coefficient xppower.com General Efficiency • 85% minimum Isolation • 3000 VAC Input to Output
Switching Frequency • 63 kHz typical MTBF • 300 kHrs to MIL-STD-217F Environmental Operating Temperature• 0 °C to +70 °C, derate from 100% power at +40 °C to 50% power at +70 °C Storage Temperature • -40 °C to +85 °C Cooling • Convection cooled Operating Humidity • 5-95% RH, non-condensing Operating Altitude • 3000 m Shock • 10 g, 10 ms on 3 axes Vibration • 5-100 Hz 2.31 m/s2, 20 mins 3 axes EMC & Safety Emissions • EN55022 FCC Part-15C Level B conducted & radiated Harmonic Current • EN61000-3-2 Class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2 Level 3 Perf criteria A Radiated Immunity • EN61000-4-3 3 V/m Perf criteria A EFT/Burst • EN61000-4-4 Level 2 Perf criteria A Surge • EN61000-4-5 Level 3 Perf criteria A Conducted Immunity • EN61000-4-6 Level 2 Perf criteria A Magnetic Field • EN61000-4-8 1 A/m Perf criteria A Dips & Interruptions• EN61000-4-11, 70% U T for 500 ms, 40% U T for 100 ms, <5% UT for 5000 ms Perf criteria A, B, B Safety Approvals • EN60950-1:2001, UL/cUL60950-1, China Compulsory Certification (CCC) qualified, CE Mark.
- Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 2. Other output voltages available, contact sales for details. Max Output Power Output Voltage(2) Output Current Total Regulation(1) Model Number 80 W 12 VDC 6.66 A 5% AEL80US12 15 VDC 5.38 A 5% AEL80US15 18 VDC 4.44 A 5% AEL80US18 24 VDC 3.33 A 5% AEL80US24 30 VDC 2.66 A 5% AEL80US30 36 VDC 2.22 A 5% AEL80US36 48 VDC 1.66 A 5% AEL80US48 Pin Connections Pin Function
1 RTN
2 RTN
4 RTN
- Output connector: 5 pin 180º DIN 3. Output cable length is 48” (1220mm) approx. 4. Weight is 1.5 lbs (700 g) 5. For European mains lead order part: EU-MAINS-IEC. 6. For UK mains lead order part: UK-MAINS-IEC. 7. For US mains lead order part: US-MAINS-IEC. Notes 5.75 (146.0) ±1.0 2.99 (76.0) AC Input IEC 320-C14 Inlet 1.69 (43.0) DC Output