  • Ch assisMoun tIndustrialSupplies
  • -25 °C to+70 °C ConvectionC ooled
  • Class B Conducted & RadiatedEmissions
  • Ou tputVoltages from 5 V to48 V
  • <0 .5W No Load InputPower
  • Low Co st
  • 2 YearWa rranty VCS Series Input InputVoltage • 85-264 VAC (127-370 VDC), see deratingcurve InputFrequency • 47-63 Hz InputCurrent • VCS50: 1.1A,VCS70: 1.4A, VCS100: 2.0 A typicalat90 VAC InrushCurrent • 60 A max at230 VAC, coldstartat25 °C Power Factor • EN61000-3-2 ClassA EarthLeakage Current • 1.0 mA maximum InputProtection • 50 & 70 W: T3.15 A/250 V 100 W: T4.0A/250 V,fusefittedinliveline No Load InputPower • <0.5 W Output Output Voltage • See model table Output Adjust • ±10.0% (5 V & 12 V versionsare-5% to+10%) InitialSet Tolerance • ±1.0% Minimum Load • None required StartUp Delay •1 s maximum Hold Up Time • 10 ms min at115 VAC and fullload LineRegulation • ±0.5%, 90 VAC to264VAC input Load Regulation • 5 V & 12 V versions:±1%, Others:±0.5% 0% to100% load TransientResponse • Less than4% deviationwitha 50% to 75% loadchange at1 A/µs.Output returnstowithin1% inlessthan500 µs Ripple& Noise • 1% maximum pk-pk,20 MHz bandwidth OvervoltageProtection • 120-140% ofnominaloutput, autorecovery OverloadProtection • 110-150% ofnominal,tripand restart ShortCircuitProtection • Continuoustripand restart Temperature • ±0.03%/°C after20 min warm up Coefficient xppo w er.com Ge neral Efficiency • See tables Isolation • 3000 VAC InputtoOutput

1500 VAC InputtoGround

500 VAC OutputtoGround

SwitchingFrequency • 65 kHz typical MTBF • >500 kHrs toMIL-STD-217F at25 °C,GB Environm ental OperatingTemperature • -25 °C to+70 °C,see deratingcurve Cooling • Convectioncooled OperatingHumidity • 0-95% R.H, non-condensing StorageTemperature • -40 °C to+80 °C OperatingAltitude • 3000 m Shock • ±3 x 30 g shocks ineach plane, 30 g:11 ms (±0.5 ms),halfsine,compliant toEN60068-2-27 & EN60068-2-47 Vibration • 10-500 Hz at2 g sweep and enduranceat resonanceinall3 planes.Conforms to EN60068-2-6 EMC & Safety Emissions • EN55022 ClassB conducted & radiated Harmonic Currents • EN61000-3-2 classA VoltageFlicker • EN61000-3-3 ESD Immunity • EN61000-4-2, level3 PerfCriteriaA RadiatedImmunity • EN61000-4-3, level3 PerfCriteriaA EFT/Burst • EN61000-4-4, level3 PerfCriteriaA (note3) Surge • EN61000-4-5, installationClass3, PerfCriteriaA Conducted Immunity • EN61000-4-6, level3 PerfCriteriaA Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, PerfCriteriaA,B, B SafetyApprovals • IEC60950-1, CSA C22.2 No.60950-1-03, UL60950-1, TUV EN60950-1

Output Power Output Voltage Output Current Ripple& Noise (2) Efficiency (1) Model Number 40 W 5.0 V 8.00 A 50 mV 79% VCS50US05 50 W 12.0 V 4.20 A 120 mV 85% VCS50US12 15.0 V 3.30 A 150 mV 86% VCS50US15 24.0 V 2.10 A 240 mV 88% VCS50US24 48.0 V 1.05 A 480 mV 88% VCS50US48 4.35 (110.5) M3 4 locations 0.75 (19.0) 0.59 (15.0) 1.14 (29.0) 3.07 (78.0) 3.82 (97.0) M3 3 locations 0.14 (3.5) 0.98 (25.0) 0.157 (4.0) 0.43 (11.0) 0.70 (17.7) 1.38 (35.0) 0.47 (12.0) 0.41 (10.5) Pin Function

1 AC Live

2 AC Neutral

3 Ground

1.Alldimensions in inches (mm ) 2.W eight:0 .55 lbs (25 0 g)approx 3 .Tolerance ±0 .02 (±0 .5) 4.Ma ximum mo unting screw penetration 0 .15 7 (4.0)from outersurface Notes DeratingCurves Output Power (%) Ambient Temperature (°C) 0 10 -10 -25 20 30 40 50 60 70 100 Output Power (%) Input Voltage (VAC) 90 100 110 120 230 240 250 85 264 100 Notes 1.Minimum averageofefficiencies measured at25%, 50%, 75% & 100% load. 2.R ipple & N oisem ay exceed specified values below -10 °C. 3.Level3 performance criteria A is m etforloads >2%. Atno load, resultis perform ance criteria A Level2 or less than4% outputdeviation atLevel3.

AC-DC VCS 70 M odeland Ratings Mec hanicalDetails 5.12 (130.0) 3.88 (98.5) 3.07 (78.0) 0.14 (3.5) 0.20 (5.0) 0.22 (5.5) 1.61 (41.0) 0.80 (20.3) 0.75 (19.0) 1.21 (30.8) 0.43 (11.0) Ø 0.13 (3.3) M3 3 locations 3.55 (90.1) 0.22 (5.5) 0.14 (3.5) 0.2 (5.1) 3.08 (78.3) 0.20 (5.2) Ø 0.13 (3.3) 1.36 (34.5) 1.26 (32.0) M3 2 locations DeratingCurves Output Power (%) Ambient Temperature (°C) 0 10 -10 -25 20 30 40 50 60 70 100 Output Power (%) Input Voltage (VAC) 90 100 110 120 230 240 250 85 264 100 Output Power Output Voltage Output Current Ripple& Noise (2) Efficiency (1) Model Number 50 W 5.0 V 10.0 A 50 mV 80% VCS70US05 70 W 12.0 V 5.83 A 120 mV 87% VCS70US12 15.0 V 4.67A 150 mV 87% VCS70US15 24.0 V 2.92A 240 mV 87% VCS70US24 48.0 V 1.46A 480 mV 87% VCS70US48 Pin Function 1.Alldim ensions in inches (mm ) 2.W eight:0 .88 lbs (400 g)approx 3 .Tolerance ±0 .0 2 (±0 .5) 4.M axim um m ounting screw penetration 0 .15 7 (4.0 )from outersurface Notes Notes 1.M inimum averageofefficiencies measured at25%, 50%, 75% & 100% load. 2.R ipple & No isem ay exceed specified valuesbelow -10 ˚C. 3.For allloads.

Output Power (%) Ambient Temperature (°C) 0 10 -10 -25 20 30 40 50 60 70 100 Output Power (%) Input Voltage (VAC) 90 100 110 120 230 240 250 85 264 100 3.87 (98.2) 6.26 (159.0) 5.49 (139.5) 0.24 (6.0) 1.08 (27.5) Ø0.13 (3.3) 0.87 (22.2) 0.71 (18.0) 0.37 (9.3) 1.02 (26.0) 0.74 (18.8) 1.65 (42.0) M3 3 locations 0.19 (4.8) 0.16 (4.0) 3.07 (78.0) 0.24 (6.0) 0.2 (5.0) 0.16 (4.0) 1.26 (32.0) 0.90 (24.0) 0.20 (5.0) 3.52 (89.5) 0.16 (4.0) 1.30 (33.0) M3 4 locations Pin Function Output Power Output Voltage Output Current Ripple& Noise (2) Efficiency (1) Model Number 70 W 5.0 V 14.0 A 50 mV 78.0% VCS100US05 100 W 12.0 V 8.33 A 120 mV 85.0% VCS100US12 15.0 V 6.67A 150 mV 86.0% VCS100US15 24.0 V 4.17A 240 mV 86.5% VCS100US24 48.0 V 2.08 A 480 mV 88.0% VCS100US48 1.Alldim ensions in inches (mm ) 2.W eight:1.1lbs (50 0 g)approx 3 .Tolerance ±0 .02 (±0 .5) 4.M axim um m ounting screw penetration 0 .15 7 (4.0)from outersurface Notes Notes 1.Minimum average ofefficiencies m easured at25%, 50%, 75% & 100% load. 2.Ripple& No isem ay exceed specifiedvaluesbelow -10 ˚C. 3.Level3 performan ce criteria A is m etforloads >10%. Atno load, resultis performance criteria A atLevel2 orlessthan5% outputdeviation atLevel3.