V1H-D1B0-001 MAGNETROL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Solitel ® Vibrating Rod LevelSwitch A P P L I C A T I O N S Powd ers and bulksolids w ithm aximum particlesize of1⁄2 inch (10 m m )including:

  • Plasticpowd ers and pellets
  • Wo od chips and sawdust
  • Pulverizedcoal
  • Flyash
  • Cem ent,lime
  • Perlite
  • Aerosil ® (fum e silica) D E S C R I P T I O N Solitel ® Vibrating Rod Level Switchesprovide reliable leveldetection of powder s and bulk solids.Thiscom - pact,integralswitch issuitable for high or low level detection in hoppers or silos.Itmay alsobe used for plugged chute detection. The single-pieceprobe and the unique self-cleancycle avoid problems ofbuildup.Sensitivityoftheinstrum ent can be adjusted to detecta variety of solid materials rangingfrom heavy granularmaterials tolightpowders with bulkdensitiesless thanone pound per cubicfoot. T E C H N O L O G Y The Solitelrod vibratesata frequency of350 Hz. When in contactwith the media, the vibrationisdampen ed. The attenuation ofthevibration isdetectedby theinte - gral mo unt electronicswhich change the state of the relay.The unique self-cleanfeature isactivatedwhen the vibration is dampen ed. The self-clean circuitry increases theamplitudeofthe vibration to dislodgeany buildup w hich may have occurred. F E A T U R E S
  • Singlerod design eliminatesclogging
  • High temperatureversion up to +320° F (+160° C)
  • Self-cleancycleand polished probe minimize solids buildup
  • Class I,Div.2 and ClassII,Div.1 approval
  • Adjustablesensitivityallows easy calibration for various bulk densities
  • Exten ded rigid probes up to 100 inches (2540 mm)
  • Exten ded flexiblelengths to 65 feet(20 meters)

F M F M Inputvoltage 110 VAC +10/-15%

220 VA C +10/-15%

24 VD C (±10%)

Powe rconsump tion Less than orequalto3 VA Ope ration frequency 350 Hz Ou tputrelay SPDT 8 amp @ 250 VAC (resistive) SPD T 1 am p @ 24 VDC (resistive) Time delay 4 to 10 seconds (dependingon sensitivity adjustment) Process connection 11⁄2"NP T H ousing NEMA 4X, 9 Ope ratingprocess temp erature Standard: -4° to+230°F (-20°to+110°C) Enhanced performan ce: -40° to+320°F (-40°to+160°C) A mbientelectronicstemperature -40° to+140° F (-40°to+60°C),referto chartbelow Relative hum idity 98% M aximum process pressure 360 PS IG M aterials Vibrating rod/Rigidextension: 316 stainlesssteel C able forflexibleprobe Polyethylenecoated steel Insertionlength Standard VXH: 8 .25inches(209mm) Extended rigidprobe VX R: 10 to100 inches (25to254 cm) Extended flexibleprobe VXK: 3 to 65 feet(1to20 meters) S P E C I F I C A T I O N S -40 F (-40 C) 0 0 -40 F (-40 C) 180 F (60 C) 95 F (35 C) 167 F (75 C) 320 F (160 C) Process Temp. Ambient Temp. I N S T A L L A T I O N IMPOR TANT: Ha ndle the instrument with greatcare,especiallythe probe. An y imp acton the probe can damag e the vibration system.

  • E nsure thatthe slope angleof the m aterialisconsideredwhen posi - tioning the probe in the vessel.
  • Wh en usingan extended version for low levelalarm,moun tthe probe above the outletof the vesselto avoid the probe being dragged along by the outflow ing m aterial.
  • Side m ounted units arebestinstalledatan angle.
  • Avoidmounting the sensor in a recessw here buildup could dampen the vibration.
  • A deflection plate is required wh en the probe isexposed to falling m aterialor,inthe case of a low levelswitch,when the drag force ofthe emptying material exceeds the specifications.
  • O bserve the specifications for bending force(F), torque(M)and pullforce(F)as indicated below: Standard: F = 100 pounds (445 N) M = 63 footpounds (85 Nm ) ExtendedRigid: M = 63 footpounds (85 Nm) ExtendedFlexible: F = 10,000pounds (45kN)

E X T E N D E D F L E X I B L E Probe Type Code R,Des ign Type Code 1 or 2 Length ininches from 10 to 100 inches (examp le:10 inches = Code 010) Probe Type Code R,Des ign Type Code 3 or 4 Length incentimeters from 25 to 254 cm (examp le25 cm = Code 025) Probe Type Code H, Des ign Type Code 1 or 3 Specify Code 000 Probe Type Code H, Des ign Type Code 2 or 4 Specify Code 000 0 110 VAC 1 220 VAC 2 24 VDC H Standard rigid probe,8.25"insertion length R E xtended rigid probe,see “Insertionlength” below

1 Standard,-4° to +230° F (-20° to +110° C),insertion length ininches

2 En hanced performance, -40° to +320° F (-40° to +160° C),insertion length ininches

3 Standard,-4° to +230° F (-20° to +110° C),insertion length incentimeters

4 En hanced performance, -40° to +320° F (-40° to +160° C),insertion length incentimeters

S T A N D A R D & E X T E N D E D R I G I D V D1B DE SIGN TY PE PROB E TY PE INSE RTIO N LE NGT H INPU T VOLT AGE VK D1B Des ign Type Code 1 Length in feetfrom 3 to 65 feet (exam ple:10 feet= Co de 010) Des ign Type Code 3 Length in m eters from 1 to 20 m eters (exam ple 15 m eters = Code 015) DE SIGN TY PE INSE RT IO N LE NGT H 0 110 VAC 1 220 VAC 2 24 VDC

1 Standard,-4° to +230° F (-20° to +110° C),insertion length infeet

3 Standard,-4° to +230° F (-20° to +110° C),insertion length inmeters

The qualityassurancesysteminplaceatMagnetrolguar - anteesthe highestlevelof qualitythroughoutthe com - pany.Magnetroliscommitted toprovidingfullcustomer satisfactionboth inqualityproductsand qualityservice. The Magnetrolqualityassurancesystem isregisteredto ISO 9001 affirmingitscommitment to known interna - tionalqualitystandardsprovidingthe strongestassur - ance of product/servicequalityavailable. All Magnetrol electronic level and flow controlsare warranted freeof defectsin materialsor workmanship forone fullyearfrom the dateof original factoryshipment. Ifreturnedwithinthewarrantyperiod;and,upon factory inspectionofthecontrol,thecause oftheclaimisdeter - mined to be covered under the warranty; then, Magnetrolwillrepairor replacethecontrolatno costto the purchaser(orowner)otherthan transportation. Magnetrol shallnot be liablefor misapplication,labor claims,director consequentialdamage or expense aris - ing from the installationor use of equipment.There are no otherwarrantiesexpressedor implied,exceptspecial writtenwarrantiescoveringsome Magnetrolproducts. BULLETIN: 56-101.8 EFFECTIVE: Decem ber2010 SU PERSEDE S:November 2006 5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com

145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738- 1306

Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-87 1317 Copyright © 2011 Magnetrol International, Incorporat ed. All rights reserved. Printed in the USA. Performance specifica tions are effective with date of issue and are subject to change without notice. For additionalinformation,see Instruction Manual 50-601. Q U A L I T Y W A R R A N T Y M agnetrol,M agnetrollogotype and SolitelareregisteredtrademarksofMagnet rolInternational Ae rosilisa registeredtradema rkofEvonikDegussa GmbH A G E N C Y A P P R O V A L S CSA VXX-D1BX-XXX ClassI,Div.2;Groups A,B, C,& D C lass II ,Div.1;Groups E,F ,& G, TYPE 4X AGE N CY MO DE L AP PROV ED APP RO VAL CLASSES These unitshave been testedtoEN 50081-2 and EN 50082-2 and arein compliancewiththeEMC Directive 89/336/EEC. These unitshave been evaluatedtothe applicableUL and CSA standards.CSA is accreditedas a NRTL (NationalRecognized TestingLaboratory)intheUnitedStates. NRTL/C 1.73 (44) Dia. 6.34 (161) Insertion length 8.25 (209) 3.44 (87) Rotation clearance 11/2" NPT process connection 3/4" NPT Conduit connection 2.75 (69) 4.63 (117) Dia. 3.63 (92) 3/4" NPT plugged 1.50 (38) 1.73 (44) Dia. 6.34 (161) Insertion length 11/2" NPT process connection 3.44 (87) Rotation clearance 3/4" NPT Conduit connection 2.75 (69) 4.63 (117) Dia. 3.63 (92) 3/4" NPT plugged 1.50 (38) 1.73 (44) Dia. 6.34 (161) Insertion length 11/2" NPT process connection 3.44 (87) Rotation clearance 3/4" NPT Conduit connection 2.75 (69) 4.63 (117) Dia. 3.63 (92) 3/4" NPT plugged 1.73 (44) Dia 1.50 (38) Standard RigidProbe Extended FlexibleProbe Extended RigidProbe D I M E N S I O N A L S P E C I F I C A T I O N S I N C H E S ( m m )