Features
- Interval Pause: 4s to 20s After-wiping Time: 2s to 20s Wiper Motor’s Park Switch Wipe/Wash Mode Priority One External Capacitor Determines All Time Sequences Relay Driver with Z-diode Interference Protection According to VDE 0839 or ISO/TR 7637/1 Load-dump Protected 1. Description The U642B is a bi-polar integrated circuit designed for the wiper application in the automotive market. It includes wipe, wash and internal mode. 2. Functional Description As a convenience feature of the windshield wiper, intermittent and wipe/wash opera- tion functions are implemented in most of the automobiles. The U642B is a cost-effective solution for an accurate timing function control. Wipe/wash mode has priority over interval mode. Interval pause and after-wiping time can be set to fixed val- ues by using resistors in a broad time r ange. Added value can be provided with an individual, continuous adjustment of the in terval pause by a potentiometer which may be built into the stalk. For proper operation, it is mandatory to feed the signal of the wiper motor's park switch into U642B. Interval and Wipe/Wash Wiper Control IC U642B Rev. 4774B–AUTO–09/05
4774B–AUTO–09/05 U642B Figure 2-1. Block Diagram Wipe/wash comparator Interval comparator Load-dump comparator Input comparator Park switch comparator 87 6 5 412 3 ABC DEF Logic VS OUT PARK WASH RtGND INT VRef VRef VRef VRef Ct
4774B–AUTO–09/05 U642B 3. Pin Configuration Figure 3-1. Pinning VS OUT WASH GND INT RT CT U642B PARK Table 3-1. Pin Description Pin Symbol Function
1 GND Ground
2 INT Interval switch
3 CT Timing capacitor C
4 RT After-wiping time resistance
5 WASH Wipe/wash switch
6 PARK Park switch for wiper motor
7 OUT Relay control output
8 VS Supply voltage terminal 15
4774B–AUTO–09/05 U642B 4. Circuit Description
4.1 Interval Function, Pin 2
By closing the interval switch, S2, to supply voltage, VBatt, the relay is activated. The internal cur- rent source (pin 3) which holds the capacitor C 2 in a charged state is switched-off. As soon as there is a positive potential at the park switch (S1), the current source F (see Figure 2-1 on page 2) charges the capacitor C 2 very quickly. After the wiper operation is finished, S 1 is again at ground potential, the relay is in the off position - interval pause begins - the capacitor C 2 is dis- charged through the curren t source C, till the voltage at pi n 3 is below the threshold of 2V. Interval pause can be adjusted between 4s to 20s with the help of potentiometer R 3. Now the relay switches on and the next interval cycle begins. Opening of switch S 2 causes the current source A to discharge C2 immediately and current sources C and F are switched-off.
4.2 Wipe/Wash (WIWA) Operation, Pin 5
By closing the WIWA switch, S 3, to supply voltage, V Batt, the water pump starts spraying water on the windshield. During this function, the current source A is switched-off which keeps the capacitor C2 in a discharged state. Now the capacitor is charged through the current sources D and F. If (after a time interval of approximately 100 ms) the voltage at the capacitor is greater than 6.5V, the relay is turned on as long as the switch WIWA is closed. The after-wiping time begins when the switch is open, the sources D and F are switched off and the source E is activated. Source E discharges th e capacitor until the voltage is less than 2.2V. The relay is off and the wiper-motor is supplied via the park switch until the park position is reached. The after-wiping time is determined by the current source E which can be regulated with the external resistor R Time . When the after-wiping time has elapsed, the source A dis- charges the capacitor. The relay switch is independent of the park switch S1.
4.3 Interval and WIWA Functions
The interval function is interrupted immediately when the wipe/wash mode is activated. The cur- rent source A discharges the capacit or to a value of 2V, afterwards, the normal wash function starts. Interval wiping starts immediately when the aft er-wipe time is over. T he switching delays are slightly shorter, because the capacitor is already charged to a value of 2V. The wipe/wash function is not interrupted when the interval switch S 2 is activated. The interval function begins after the WIWA function has elapsed.
4774B–AUTO–09/05 U642B Figure 4-1. Application Circuit with Interval and Wipe/Wash Operation 1 2 6 58 7 3 4 10 kΩ R6 47 µF 10 V 22 µF Rtime = 130 KΩ510 Ω 10 kΩ MM Relay Park switch Wiper motor Interval switch Water pump WIWA U642B 2.7 kΩ 10 kΩR5
4774B–AUTO–09/05 U642B 5. Absolute Maximum Ratings Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Parameters Pin Symbol Value Unit Supply voltage t = 60s, terminal 15 8 V Batt 28 V Supply current t = 2 ms t = 200 ms 8I 8 1.5 150 A mA Relay control output current (DC) t = 200 ms 7 I7 200 1.2 mA A Pulse Current (Control Inputs) t = 200 ms Park switch, S1 Wipe/Wash switch, S3 Interval switch, S2 mA Power dissipation Tamb = 90°C P tot 500 mW Storage temperature range T stg –55 to +125 °C Ambient temperature range T amb –40 to +85 °C 6. Thermal Resistance Parameters Symbol Value Unit Junction ambient DIP8 R thJA 120 K/W SO8 R thJA 160 K/W
4774B–AUTO–09/05 U642B 7. Electrical Characteristics VBatt = 12V, Tamb = 25°C, reference point is pin 8 (see Figure 4-1 on page 5) unless otherwise specified. Parameters Test Conditions Pin Symbol Min. Typ. Max. Unit Supply voltage V Batt 91 6 . 5 V Supply current I 8 10 mA Z-diode limitation V 1 7.6 V Overvoltage Threshold current I1 –50 mA Threshold voltage V Batt 35 V Relay Control Output 7 Saturation voltage I7 = 100 mA I7 = 200 mA V7 –1.0 –1.5 V Leakage current I 7 100 µA Park Switch 6 Internal pull-up resistance R 6 = 10 kΩ R6 50 k Ω Switching threshold voltage V 6 –3.3 V Protection diode I6 = –10 mA I6 = 10 mA –0.8 7.6 V V Input Ct 3 Internal resistance R 3 100 Ω Interval Input R2 = 2.7 to 30 kΩ 2 Protection diode I2 = –10 mA I2 = 30 mA/10 ms V2 –0.8 7.6 V WASH Input R5 = 10 kΩ 5 Switching threshold/ Hysteresis V5 –1.4/ –5.4 V Protection diode I5 = –10 mA I5 = 10 mA V –0.8 7.6 V Switching Characteristics R4 = 47 kΩ to 300 kΩ, I4 = –150 µA Interval time R3 = 0 kΩ R3 = 10 kΩ t2 3.6 10.8 4.4 13.2 s Prewash delay t del 100 ms After-wipe-time R 4 = 130 kΩ 5t 5 4.75 5.25 5.75 s
4774B–AUTO–09/05 U642B Figure 8-4. After-wiping Time = f (T); Ct = 22 µF; VBatt = 16V -40 -20 0 20 40 60 80 100 Temperature (°C) Afterwiping Time (s) Rtime = 130 kΩ Rtime = 300 kΩ Rtime = 51 kΩ VBatt = 16 V
4774B–AUTO–09/05 U642B 10. Package Information 9. Ordering Information Extended Type Number Package Remarks U642B-MY DIP8 Pb-free U642B-MFPY SO8 Tubed, Pb-free U642B-MFPG3Y SO8 Taped and reeled Dimensions in mm specifications according to DIN technical drawings 9.8 max. 2.54 nom. 0.3 0.36 max. B 0.4 A A B 1.54 0.65 9.6±0.1 7.62±0.15 3.6±0.1 4.2±0.3 1.8 6.7 2.5 1.2±0.3 0.53±0.05 6.3±0.1 Issue: 1; 16.01.02 Drawing-No.: 6.543-5040.01-4
4774B–AUTO–09/05 U642B 11. Revision History technical drawings according to DIN specifications Dimensions in mm 5.00 4.85 0.4 1.27 3.81 1.4 0.25 0.10 5.2 4.8 3.7 3.8 6.15 5.85 0.2 Please note that the following page numbers referred to in this section refer to the specific revision mentioned, not to this document. Revision No. History 4774B-AUTO-09/05
- Put datasheet in a new template
- Pb-free logo on page 1 added
- Ordering Information on page 10 changed
Printed on recycled paper. 4774B–AUTO–09/05 © Atmel Corporation 2005 . All rights reserved. Atmel ®, logo and combinations thereof, Everywhere Y ou Are ® and others, are registered trade- marks or trademarks of Atmel Corporation or its subsidiari es. Other terms and product names may be trademarks of others. Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise, to any intellectual property right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL ’S TERMS AND CONDI- TIONS OF SALE LOCATED ON ATMEL ’S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTOR Y WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICU LAR PURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL OR I NCIDEN- TAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR LOSS OF INFORMATION) ARISING OUT OF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF AT MEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no representations or warranties with respect to the accuracy or completeness of the contents of this document and reserves the ri ght to make changes to specifications and product descriptions at any time without notice. Atmel does not make any commitment to update the information contained her ein. Unless specifically provided otherwise, Atmel products are not suitable for, and shall not be used in, automotive applications. Atmel’s products are not int ended, authorized, or warranted for use as components in applications intended to support or sustain life. Atmel Corporation Atmel Operations
2325 Orchard Parkway
San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 487-2600 Regional Headquarters Europe Atmel Sarl Route des Arsenaux 41 Case Postale 80 CH-1705 Fribourg Switzerland Tel: (41) 26-426-5555 Fax: (41) 26-426-5500 Asia Room 1219 Chinachem Golden Plaza
77 Mody Road Tsimshatsui
Tel: (852) 2721-9778 Fax: (852) 2722-1369 Japan 9F, Tonetsu Shinkawa Bldg. 1-24-8 Shinkawa Chuo-ku, Tokyo 104-0033 Japan Tel: (81) 3-3523-3551 Fax: (81) 3-3523-7581 Memory San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 436-4314 Microcontrollers San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 436-4314 La Chantrerie BP 70602
44306 Nantes Cedex 3, France
13106 Rousset Cedex, France
1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906, USA Tel: 1(719) 576-3300 Fax: 1(719) 540-1759 Scottish Enterprise Technology Park Maxwell Building East Kilbride G75 0QR, Scotland Tel: (44) 1355-803-000 Fax: (44) 1355-242-743 RF/Automotive Theresienstrasse 2 Postfach 3535
74025 Heilbronn, Germany
1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906, USA Tel: 1(719) 576-3300 Fax: 1(719) 540-1759 Biometrics/Imaging/Hi-Rel MPU/ High Speed Converters/RF Datacom Avenue de Rochepleine BP 123
38521 Saint-Egreve Cedex, France
www.atmel.com/literature