TX7320 TANDAUK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Features and Benefits

  • EN54-3 Compliance
  • Built-in MCU processor and digital addressing
  • 17 tones Programmable sound output
  • Programmable Evacuate or Pre-alarm/Evacuate signal
  • Low and normal consumption mode
  • One or Two addresses mode
  • Onsite Adjustable Parameters
  • Loop or external power input
  • Aesthetically pleasing design
  • Universal mounting with fix base for simple installation Overview The TX7320 Addressable Sounder is alarm warning device used to notify persons in the vicinity of the occurrence fire emergency in order the person to take appropriate measures. The unit adopt multi-application device starting from the types, parameters and wiring layout in single unit. The parameters can be configured according to the requirement which include alarm tone from 17 different tones, single address or dual address mode and also setting of power mode to low current consumption in a simple programming. The unit manufactured base on the requirement of EN 54 part 3, European Standard. The unit is aesthetically pleasing with unobtrusive design that will complement modern building designs and its plug-in type assembles make installation and maintenance more convenient to the installer. The unit is compatible to the TX7004 Analogue Intelligent Fire Alarm Control Panel, produced by single manufacture T&A, to avoid addressable communication compatibility problem.

Colour ABS / RED Glossy finishing 1st Alert Tone / 2nd Evacuate tone Dimension / Height Operating Temperature Humidity Ingress Protection Rating Dual Address Diameter 110 mm / 39.6 (with Base) -10°C to +50°C IP21 0 to 95% Relative Humidity, Non condensing Weight 180g (with Base), 114g (without Base) Class Type A, Indoors Listed Compliance LPCB Pending EN54-3 Power Rating Loop Power: 24VDC [18V to 27.5V] External PSU Loop and External PSU Saving Current 24VDC [20V to 27.5V] Standby 0.6mA, Alarm: 10mA Standby 1.2mA, Alarm: 4mA Typical Current Loop: Standby 0.6mA, Alarm: 1.5mA Input Voltage Sounder T&A, Value range from 1 to 254 Single Address: Evacuate tone Protocol/ Addressing Address Sequence Technical Specification Sounder and Wiring Details 1. Signal In (+) 2. Signal Out (+) 3. External PSU In (+) Optional 4. External PSU Out (+)Optional 5. Signal In (-) 6. Signal Out (-) 7. External PSU In(-)Optional 8. External PSU Out (-)Optional Terminal Description (24VDC) Loop Powered Wiring Details With External Supply Wiring Details