TR660IP ZIEHL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 1
Technical content
ZIEHL industrie-elektronik, 74523 Schwäbisch Hall, Germany, +49 791 504-0, info@ziehl.de, www.ziehl.de Pt 100 Temperature Relays Type TR TR660IP Part numbers: TR660IP analog T224370 2 analog outputs programmable 0/4 - 20 mA / 0/2 - 10 V TR660IP RS485 T224371 interface RS485 (modbus RTU) planned availability september 2019 Operation can be made at the device or with a standard browser via ethernet. 6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible 7 alarms / output relays alarm 2 of x = alarm only when limit is exceeded in min. 2 sensors monitoring of difference of temperatures monitoring of rate of change of temperature logging of temperatures and history preset programs for protection of motors, transfor- mers and more interface ethernet TCP/IP, values available via modbus TCP programming with browser via TCP/IP or with joy- stick at device coloured LCD display for clear display of tempera- tures and states of alarms universal power supply AC/DC 24-270 V Temperature relay TR660IP Sensors 6 x Pt 100, Pt 1000 or PTC, 7 limits, analog outputs or interface RS485, IP interface, operation with browser via TCP/IP Technical data Rated supply voltage Us Sensor connection Type of connection Monitoring range Switching delay on/off Relay output Test conditions Rated ambient temperature range Housing Dimensions (w x h x d) Protection housing/terminals Mounting Weight AC/DC 24 - 270 V, 0/50/60 Hz 6 x Pt 100, Pt 1000, PTC 3-wire, 2-wire (line resistance 0,0...99,9 Ohm) -199,9...+800 °C 7 x changeover contact EN 61010, EN 61326 -20°C...+65°C Design V8 140 x 90 x 58 mm, mounting height 55 mm IP 30 / IP 20 snap mount on 35 mm DIN rail or screws M4 app. 400 g Temperature Relays TR660IP monitor up to 6 sensors for up to 7 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC-thermistors. Typical appli - cations are monitoring of motors, generators or transformers. An other application is the use as a 2- or more step-controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors. Preset programs allow easy setting e.g. monitoring of trans- formers with/without monitoring of temperature of core or with/ without controlling a ventilator. 2019-07-19 3T1 3T2 3T3 4T1 4T2 4T3 5T1 5T2 5T3 6T1 6T2 6T32T1 2T2 2T31T1 1T2 1T3 74A1 NCA2 Maßstab: Zeichnungsnummer: EA-Nr.: Blatt:Ers. für: bearbeitet: Bezeichnung:Kurzbezeichnung: Anschlussplan 1583x1:1 1 von 1 12780-0900-00 2018-11-15 / sm Temperaturrelais mit AnalogausgangTR660IP 12780-1200-00Menu 2 s www.ziehl.de U1 I1 U2 Y2Y1 LAN Reset 12 11 14 22 21 24 32 31 34 42 41 44 K2 K3 K4 52 51 54 62 61 64 72 71 K5 K6 K7 Temperaturrelais TR660IP Pt100 / Pt1000 PTC OUT1 OUT2 Sensor 1T Sensor 2T Sensor 3T Sensor 4T Sensor 5T Sensor 6T kΩ kΩ K1 K2 K3 K4 K5 K6 K7 14,8 -199,9 799,0 3,6 0,4 --- Max Min T M M T Us DC + AC ~ Pt100, Pt1000, PTC Reset V A V A [12780-0900-00]