ZIEHL industrie-elektronik, 74523 Schwäbisch Hall, Germany, +49 791 504-0, info@ziehl.de, www.ziehl.de Relay K1: continous vibration 20 s or impulse- vibration 18 s with 3 s clock Relay K2: impulse-vibration 40 s with clock 0,5 s or 0,8 s (for magnet valves) LED (red) signals deceleration time LED (green) signals vibration action automatic interruption of the vibration action when starting the suction process. Vibrator Control Type RS1K Start of deceleration time by break contact at Y1/Z0 (e.g. from contactor suction motor) Starting of deceleration time through current transformer STWA 1 at Z0/Z1 (e.g. L1 from suction motor) adjustable deceleration time 1...30 min. The vibrator control RS1K is a compact multiple time relay for triggering of vibrators in suction plants. In order to be able to ope- rate suction plants at an optimum, the filters which get clogged by sawdust, chips or dust, have to be dedusted by vibration from time to time. The vibration action is by no means to be carried out the suction running or while slowing down the ventilator. If suctioning is started during vibration, the process is immediately to be interrupted. Prior to starting the vibration action, an adjustable deceleration time is running to delay the ventilator before start of vibration. This means that short stoppages can be by- passed without being obliged to carry out a vibration every time. A1 A2 18 15 16 28 25 26 Z1 Z0Y1 Y2 STWA1 gn rt AC 15 Ue = 250 V Ie = 3 A AC/DC 24...240 V 0/50/60 Hz <2 W <4 VA V R ~+ Us ~– 40 / 0,8 s V 20 s 1...30 min 40 / 0,5 s18 / 3 s Y2 Z0 RS1K Rüttlersteuerung K3 K4 N *1 STWA1 .com Made in Germany Rated Voltage Supply Us Input Y1/Z0, Y2/Z0 Input Z1/Z0 Switching current Overload Capacity of transfor- mer Relay-Output Type of Contact Test Conditions adm. ambient temperature Dimensions H x B x T Fitting position Protection Housing/Terminals AC/DC 24...240 V, AC 19-264 V, DC 20-297 V < 2VA Contact, Breaker (nc), 18 V, 3 mA Current Transformer STWA1 ON ≥ AC 1 A, OFF ≤ AC 0,4 A max. 100 A continous, 300 A / 10 s 2 x 1 co Type 2 (see general technical informations) see "general technical informations" -20...+55°C Design K: 75 x 22,5 x 115 [mm] on 35 mm standard rail according to DIN EN 60 715 or screws M4 (not included in delivery scope) IP 30/IP 20 Technical Data Function diagram: 2015-10-21 RS1K Part number: Z224302 Controls for Suction Plants Type STW