TR10 Series D C -D C C onverter x x x Series w w w .xppow er.com 1 M odels & Ratings
- 3 Pin Switching Regulator
- SIP Package
- -40 °C to +85 °C Operation
- Full Load to 60 °C Ambient
- Wide Input Range to 28 V
- Class B Conducted & Radiated Emissions
- MTBF >3.8 MHrs
- 3 Year Warranty Dim ensions: TR10:
1 Amp
Input Voltage O utput Voltage O utput C urrent Input C urrent M ax. C apacitive Load Efficiency M odel N um ber N o Load Full Load, m in. Vin Full Load, m ax. Vin M in. Vin M ax. Vin 7-28 V 3 .3 V 1 000 m A 1 .5 m A 53 0 m A 1 45 m A 220 µF 89 % 82% TR 1 0S3 V3 8-28 V 5.0 V 1 000 m A 1 .5 m A 670 m A 21 0 m A 220 µF 9 3 % 86% TR 1 0S05 0.46 (11.68) 0.29 (7.5) 0.16 (4.1) 0.38 (9.66) 0.02 (0.50) 123 0.10 (2.54) 0.20 (5.08) 0.40 (10.16) Printed Face 0.02 (0.50) 123 2.0 (0.08) 0.30 (7.70) 0.20 (5.08) 0.01 (0.25) 1 . A ll dim ensions are in inches (m m ) 2. W eight: 0.004 lbs (2.1 g) approx. 4. Pin pitch tolerance: ±0.01 4 (±0.3 5) 5. Case tolerance: ±0.02 (±0.5) N otes Pin C onnections Pin Single 1 +Vin
2 G round
w w w .xppow er.com 2 D C -D C C onverter Input O utput C haracteristic M inim um Typical M axim um U nits N otes & C onditions O utput Voltage 3 .3 5 VD C See M odels and R atings table Initial Set A ccuracy 2.5 % A t full load M inim um Load 1 00 m A M inim um load required to m eet specification. O peration at no load w ill not cause dam age. Line R egulation 1 .0 % Load R egulation 1 .5 % F rom 1 0% to full load T ransient R esponse ±3 % F or 25% load change R ipple & N oise 1 00 m V pk-pk 20 M H z bandw idth Short Circuit Protection Continuous, w ith auto recovery M axim um Capacitive Load See M odels and R atings table T em perature Coefficient 0.02 %/ ˚C C haracteristic M inim um Typical M axim um U nits N otes & C onditions Input Voltage R ange 7 28 VD C See M odels and R atings table Input F ilter Capacitor Input R eflected R ipple 3 5 m A pk-pk Through 1 2 µH inductor and 47 µF capacitor Input Surge 3 0 VD C for 1 00 m s G eneral C haracteristic M inim um Typical M axim um U nits N otes & C onditions E fficiency 9 0 % See m odels and ratings table Isolation: Input to O utput 0 VD C N on isolated Sw itching F requency 3 3 0 kH z M ean Tim e B etw een F ailure 3 .8 M H rs M IL-H D B K-21 7F , +25 °C G B W eight 0.004 (2.1 ) lb (g) Environm ental C haracteristic M inim um Typical M axim um U nits N otes & C onditions O perating T em perature -40 +85 °C D erate from 1 00% load at +60 °C to 40% at +85 °C Storage T em perature -55 +1 25 °C Case T em perature +105 °C H um idity 9 5 % R H N on-condensing Cooling N atural convection EM C: Im m unity Phenom enon Standard Test Level C riteria N otes & C onditions E SD Im m unity E N 61 000-4-2 ±6 kV/±8 kV A C ontact discharge/Air discharge R adiated Im m unity E N 61 000-4-3 20 Vrm s A E F T/B urst E N 61 000-4-4 ±2.0 kV A External input capacitor required 330 µF/100 V Surges E N 61 000-4-5 ±0.5 kV A External input capacitor required 330 µF/100 V Conducted Im m unity E N 61 000-4-6 1 0 V rm s A M agnetic F ields E N 61 000-4-8 1 00 A /m A EM C: Em issions Phenom enon Standard Test Level N otes & C onditions Conducted E N 5503 2 Class B See Application N ote R adiated E N 5503 2 Class B
w w w .xppow er.com D C -D C C onverter 3 11 Jan 17 Standard Application EM I Filter A pplication N ote +Vin -Vin +Vout -Vout TR10 C1 = 22 µF C2 = 47 µF (optional) to improve transient response C1, C2 and L1 should be placed as close to the TR10 as possible C1 = 10 µF, 50 V L1 = 22 µH C2 = 10 µF, 50 V +Vin -Vin LoadC2 TR10