DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

Page 1 of 3 www.aecsensors.com Sales Department Tel: (888) 847-6552 TLS series electronic tilt switches Specifications Contact number & arrangement 2 x SPST-NO ( 2 x Form A), 2 x SPST-NC1 ( 2 x Form B1) Max. switching voltage AC/DC 250VAC / 30VDC Min. breaking capacity W 50mW Rated load (resistive - cos φ=1) AC1 5A/250VAC (Consult factory for higher currents) DC1 5A/30VDC Max. switching power 1250VA / 150W 1) NC function requires the tilt switch to be powered at all times. Supply voltage AC/DC 5 - 18VDC, 17 - 35VDC, 12 - 24VAC (see Ordering Codes, Page 2) Current consumption <150mA (both output relays energized) Trigger angle range 180° (+/- 90° from horizontal) depending on part number Reset range (minimum) 0.5° less than trigger angle Resolution 0.1° Accuracy 0.5° Time Delay (factory set) secs 0 to 5 seconds in 100 msec steps Housing Polycarbonate (UL94-HB) Dimensions (approx.) L x W x H 5.71” (over mounting flange) x 2.56” x 2.17” (145 x 65 x 55mm) Weight 0.38lb (172g) Ambient temperature -40 to 70°C Sealing IP65 Shock resistance 10g Vibration resistance 1.5mm DA 10...55Hz Wiring Information Cable length 12 inches (approx. 305mm) Cable colors Red & Black 5 - 12V supply (AC or DC) Yellow & Blue Switch output 1 (volt free contact) Brown & Orange Switch output 2 (volt free contact) - where fitted.

  • Wide trigger angle of up to 180 Degrees
  • Factory Programmable hysteresis on reset angle
  • Up to 5 Second delay on trigger and reset angle.
  • Relay output switching up to 5A at 250VAC
  • Two independent trigger and reset angles
  • RoHS Compliant Ref: TLS Series 012913JHM

All dimensions in inches. Not to scale. Page 2 of 3 www.aecsensors.com Sales Department Tel: (888) 847-6552 TLS series electronic tilt switches Ref: TLS series 012913JHM Dimensions and mounting holes Fig. 1 Ordering codes Type 1st Trigger Angle 1st Reset Angle 2nd Trigger Angle 2nd Reset Angle Time Delay T L S - - - - - - Axis1 L

1 See Fig 2 for explanation of axisW 1st Trigger angle 1st Reset angle3

H 01 ~ 90 0.5 ~ 89.5 Switch function 2nd Trigger angle 2nd Reset angle3 C - 2 x SPST-NO 01 ~ 90 0.5 ~ 89.5 D - 2 x SPST-NC2 NB: Actual angle is negative - refer to Fig 2 for more information

2 Normally closed contacts require power supplied to

switch at all times. 3 Minimum reset angle = 0.5 degrees less than trigger angle Operating supply voltage Time delay (on Trigger) A - 5 - 18VDC NIL - No time delay B - 17 - 35VDC 0.1 ~ 5 seconds (in 100msec steps) C - 12 - 24VAC Time delay is the same for 1st and 2nd Trigger angles. ( 2.559 ) ( .256 ) ( 2.171 ) 1.69 0.65

Mounting Instructions Fig. 2 TLS series electronic tilt switches American Electronic Components Inc., 1101 Lafayette St. Elkhart, IN46516 Page 3 of 3 www.aecsensors.com Sales Department Tel: (888) 847-6552 Specifications are subject to change without notice. E&OE. Ref: TLS series 012913JHM L Axis H Axis W Axis Switch mounted in horizontal plane Switch mounted in vertical plane The Tilt Switch should be mounted in the horizontal plane for L or W axis and in the vertical plane for H axis. The factory can pre- program an offset for when the Tilt Switch is required to be mounted at an angle. The Tilt Switch may be mounted using the four corner holes (preferred) or the two key hole slots at each end of the unit. Do not drill the box as this may damage the internal components and will compromise the sealing. Please ensure sufficient space is left to allow for the cable. Undue stress on the cable should be avoided. Wiring Information The Tilt Switch has a six wire cable for connection. As standard, the unit is supplied with a 12” cable - other lengths can be supplied (contact factory). The Tilt Switch is not fused internally and a suitable external fuse should be fitted. Wire Color Function Red +ve Supply (AC or DC) Black -ve Supply (AC or DC) Yellow Switch 1 Common Blue Switch 1 NO (NC) Brown Switch 2 Common Orange Switch 2 NO (NC) The Tilt Switch will work with any supply voltage within the chosen voltage range. The internal switches are factory programmed as either normally open or normally closed. The normally closed function requires the Tilt Switch supply voltage to be present at all times. Disconnecting the supply to the Tilt Switch will cause the normally closed contact to open. If the normally closed function is selected, the contact will close im- mediately after the supply voltage is applied to the Tilt Switch. Switch outputs are “volt free” and may be used for switching voltages up to 230VAC and a maximum current of 5A per switch. (Contact factory for special requirements). Switch Function SPST-NO: The switch contacts are open when the Tilt Switch is in the at rest position. The switch contacts will close (make) when the trigger angle setpoint is reached and open (break) again at the reset angle setpoint as the Tilt Switch returns to the at rest position. SPST-NC: The switch contacts close (make) as soon as power is supplied to the Tilt Switch, with the Tilt Switch in the at rest position. The switch contacts will open (break) when the trigger angle setpoint is reached and close again at the reset angle setpoint as the Tilt Switch returns to the at rest position.