TOSHIBA LED Lamp InGaA ℓP Red Light Emission TLRH190P Panel Circuit Indicator /Gb7/G2010 mm diameter /Gb7/G20InGaAℓP red LED /Gb7/G20All plastic mold type. /Gb7/G20Colorless clear lens /Gb7/G20Low drive current, high intensity red light emission Recommended forward current: I F = 1~20mA (DC) /Gb7/G20All plastic molded lens, provides an excellent on−off contrast ratio. /Gb7/G20Fast response time, capable of pulse operation. /Gb7/G20High power luminous intensity /Gb7/G20Without stand−offs /Gb7/G20Applications: Suitable for outdoor message signboard, safety equipment. Maximum Ratings (Ta = 25°C) Characteristic Symbol Rating Unit Forward current (DC) I F 50 mA Reverse voltage V R 4 V Power dissipation P D 125 mW Operating temperature range T opr /G2d30~85 °C Storage temperature range T stg /G2d40~120 °C Electrical And Optical Characteristics (Ta = 25°C) Characteristic Symbol Test Condition Min Typ. Max Unit Forward voltage V F I F = 20 mA /Gbe 1.9 2.5 V Reverse current I R V R = 4 V /Gbe /Gbe 50 µA TLRH190P 4760 19000 /Gbe Luminous intensity TLRH190P (WX) IV I F = 20 mA (Note) 8500 /Gbe 41400 mcd Peak emission wavelength λP I F = 20 mA /Gbe 644 /Gbe nm Spectral line half width ∆λ I F = 20 mA /Gbe 18 /Gbe nm Dominant wavelength λd I F = 20mA /Gbe 630 /Gbe nm (Note): Lamps are classified into the following ranks according to their luminous intensity. Measurement tolerance for each limit is /Gb115%. V: 5600−11200mcd, W: 10000−20000mcd, X: 18000−36000mcd. Unit in mm JEDEC ― EIAJ ― TOSHIBA Weight: 1.0 g
Please be careful of the followings /Gb7/G20Soldering temperature: 260°C max Soldering time: 3 s max (Soldering portion of lead: Up to 2 mm from the body of the device) /Gb7/G20If the lead is formed, the lead should be formed up to 5 mm from the body of the device without forming stress to the resin. Soldering should be performed after lead forming. /Gb7/G20This visible LED lamp also emits some IR light. If a photodetector is located near the LED lamp, please ensure that it will not be affected by this IR light.
1.6 Forward voltage V F (V) Forward current I F (mA) IF – VF Ta = 25°C 100000 500 50000 30000 10000 5000 3000 1000 30 50 100 0.5 3 5 10 Forward current I F (mA) Luminous intensity I V (mcd) IV – IF Ta = 25°C 1.0 580 0.8 0.6 0.4 0.2 600 620 640 660 680 700 Wavelength λ (nm) Relative luminous intensity IF = 20mA Ta = 25°C Relative Luminous Intensity _ Wavelength Case temperature Tc (°C) Relative luminous intensity I V IV – Tc 0.1 − 20 0.3 0.5 0 20 40 60 80 Radiation Pattern Ta = 25 °C 70° 70° 60° 50° 40° 30° 30° 40° 50° 60° 80° 90° 80° 20° 10° 0°10° 20° 90° 0.8 0.6 0.4 0.2 0 Ambient temperature Ta (°C) 0 20 40 60 80 100 Allowable forward current IF ( m A ) IF – Ta
/Gb7/G20TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc.. /Gb7/G20The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk. /Gb7/G20Gallium arsenide (GaAs) is a substance used in the products described in this document. GaAs dust and fumes are toxic. Do not break, cut or pulverize the product, or use chemicals to dissolve them. When disposing of the products, follow the appropriate regulations. Do not dispose of the products with other industrial waste or with domestic garbage. /Gb7/G20The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any intellectual property or other rights of TOSHIBA CORPORATION or others. /Gb7/G20The information contained herein is subject to change without notice. 000707EACRESTRICTIONS ON PRODUCT USE