The TL3 columns from TiMOTION are made up of three extruded aluminum tubes of rectangular shape that give the system great stability and a high stroke with reduced retracted length. This electric lifting column allows for an easy integration into many height adjustable workstation applications, such as an exam chair in healthcare industry. General Features Max. load 4,000N (push) Self-locking force 4,000N Max. dynamic bending moment 1,000Nm Max. static bending moment 2,000Nm Max. speed at max. load 13.7mm/s Max. speed at no load 39mm/s Retracted length ≥ Stroke / 2+150mm IP rating IPX6 Dimension of outer tube 177.4*150.7mm rectangular Stages 3-stage Stroke 250~1200mm Certificate IEC60601-1, EMC Output signals POT, Hall sensors Options Direct cut system Voltage 12V DC; 24V DC (thermal control) Operational temperature range +5°C~+45°C Product Segments

  • Care Motion
  • Comfort Motion
  • Ergo Motion
  • Industrial Motion TL3 series

(mm) Drawing Retracted Length 150.7 130 110 133 160 177 .4 121M8 155 135

1 Parameters above are from tested average, please refer to approval drawing for final value. 2 This self-locking force level is reached only when a short circuit is applied on the terminals of the motor. All the TiMOTION control boxes have this feature built-in. 3 The current & speed in table are tested with 24V DC motor. With a 12V DC motor, the current is approximately twice the current measured in 24V DC; speed will be similar for both voltages. 4 Bending moment Y direction = X*0.8

5 Static bending moment = dynamic*2

CODE Load (N) Self Locking Force (N) Typical Current (A) Typical Speed (mm/s) Push No Load 32V DC With Load 24V DC No Load 32V DC With Load 24V DC Motor Speed (2200RPM, duty cycle 10%) B 4000 4000 2.5 6.3 14.5 7.6 C 2000 2000 2.5 4.3 22.0 13.0 D 1000 1000 2.5 3.8 39.0 24.0 Motor Speed (2800RPM, duty cycle 10%) E 4000 4000 3.5 7.5 18.5 9.4 F 2000 2000 3.5 6.3 35.0 20.0 Motor Speed (3800RPM, duty cycle 10%) G 4000 4000 4.0 10.8 28.0 13.7 Dynamic bending moment (Nm)- X direction Stroke (mm) S/2+150 S/2+220 100-300 700 1000 301-500 500 800 501-700 300 500 701-1200 200 200 Bending moment X Bending moment Y

Motor Speed (2200RPM, Duty cycle 10%) Performance Data (24V DC Motor) TL3 series 35.0 40.0 30.0 25.0 20.0 15.0 10.0 0.0 5.0 0 1000 2000 3000 4000500 1500 2500 3500 D C B Speed (mm/s) Speed vs. Load Load (N) 6.0 4.0 10.0 8.0 0.0 2.0 0 1000 2000 3000 40001500 2500 3500500 C D B Current (A) Current vs. Load Load (N)

Motor Speed (2800RPM, Duty cycle 10%) Performance Data (24V DC Motor) TL3 series 0 1000 2000 3000 4000500 1500 2500 3500 40.0 35.0 30.0 25.0 20.0 15.0 10.0 5.0 0.0 F E Speed (mm/s) Speed vs. Load Load (N) 8.0 10.0 6.0 4.0 0.0 2.0 10000 2000 3000 4000500 1500 2500 3500 F E Current (A) Current vs. Load Load (N)

Motor Speed (3800RPM, Duty cycle 10%) Performance Data (24V DC Motor) TL3 series 0 1000 2000 3000 4000500 1500 2500 3500 30.0 20.0 10.0 0.0 35.0 25.0 15.0 5.0 G Speed (mm/s) Speed vs. Load Load (N) 2.0 10.0 8.0 6.0 4.0 0.0 0 1000 2000 3000 4000500 1500 2500 3500 G Current (A) Current vs. Load Load (N)

Version: 20220411-V Load and Speed Voltage Output Signals IP Rating Functions for Limit Switches See page 11 1 = 12V DC 5 = 24V DC, thermal control 250~1200 0 = Without 2 = Hall sensors*2 3 = POT 1 = DIN 6P , socket 2 = DIN 6P , socket, with Anti-pull buckle 1 = Without 2 = IPX4 3 = IPX6 1 = Two switches at full retracted / extended positions to cut current 3 = Two switches at full retracted / extended positions to send signal Stroke (mm) Retracted Length (mm) Grounding Function 0 = Without 1 = With See page 3 See page 10 Cable Exit See page 10 Tubes Direction See page 12 Special Functions for Spindle Sub-assembly 1 = Top end socket Connector See page 11 Color 1 = Black 2 = Matte silver Cable Length (mm) 0 = Without (The corresponding extension cable TEC needs to be ordered seperately*) Note: please contact TiMOTION before making an order 0 = Thinner on top 0 = Without (Standard) 1 = Safety nut Note 1 The TL3 is designed especially for push applications, not suitable for pull applications.

Version: 20220411-V Load and Speed Voltage Output Signals IP Rating Functions for Limit Switches See page 11 1 = 12V DC 5 = 24V DC, thermal control 250~1200 0 = Without 2 = Hall sensors*2 3 = POT 1 = Without 2 = IPX4 3 = IPX6 1 = Two switches at full retracted / extended positions to cut current 3 = Two switches at full retracted / extended positions to send signal Stroke (mm) Retracted Length (mm) See page 3 See page 10 Cable Exit See page 10 Special Functions for Spindle Sub-assembly 2 = Bottom side cable 3 = Top side cable 4 = Top (to TC) + Bottom (to TH) side cable (Please discuss the way of cable exit and retracted length with our engineer) 0 = Without (Standard) 1 = Safety nut Connector See page 11 1 = DIN 6P , 90° plug 2 = Tinned leads F = DIN 6P , 180° plug G = Molex 8P 90° H = Molex 8P 180° Color 1 = Black (Black cable set) 2 = Silver (428C color cable set) 3 = Silver (Black cable set) Cable Length (mm) 1 = Straight, 500 2 = Straight, 750 3 = Straight, 1000 4 = Straight, 1250 5 = Straight, 1500 6 = Straight, 1750 7 = Straight, 2000 Grounding Function 0 = Without 1 = With 0 = Thinner on top 1 = Wider on top Note: If "top+bottom cable" in Cable Exit section is selected , could only select #0 Tubes Direction See page 12 Note 1 The TL3 is designed especially for push applications, not suitable for pull applications.

Version: 20220411-V Load and Speed Voltage IP Rating Functions for Limit Switches See page 11 5 = 24V DC, thermal protector 100~1200 0 = Without C = Direct cut, water proof, anti-pull 1 = Without 2 = IPX4 3 = IPX6 1 = Two switches at full retracted / extended positions to cut current Stroke (mm) Retracted Length (mm) Color 1 = Black (With black cable set) 2 = Matte silver (With 428C color cable set) 3 = Matte silver (With black cable set) See page 3 See page 10 Cable Exit See page 10 Cable Length (mm) See page 12 Special Functions for Spindle Sub-assembly B = Top side - for TH; Bottom side - for TP C = Bottom side - Y cable, for TH + TP D = Top side - for the 2nd column; Bottom side - for TH & TP; direct cut operation with 2 columns E = Top side - for the 2nd column & TH; Bottom side - for TP; direct cut operation with 2 columns B = Cable exit #B, L2 = L3 = 100 C = Cable exit #C, L1 = L2 = L3 = 100 D = Cable exit #D, L2 = L3 = L4 = 100 E = Cable exit #E, L2 = L3 = L4 = 100 0 = Without (Standard) 1 = Safety nut Output Signals Connector See page 11 Grounding Function 0 = Without 1 = With 0 = Thinner on top 1 = Wider on topTubes Direction See page 12 Note 1 The TL3 is designed especially for push applications, not suitable for pull applications.

  1. Retracted length needs to > A+B+C Retracted Length (mm) B. Cable Exit CODE Top End Socket Bottom Side Cable Top Side Cable Top + Bottom side cable Direct Cut 1 - - - - - 2 - - - - - 3 - - +15 - - B - - - +35 - C - - - - - C. When with POT (When without POT, C = 0) Cable Exit Code Top End Socket Bottom Side Cable Top Side Cable 1 +40 - - 2 - +40 - 3 - - +40 A. Load (N) 1000 2000 4000 Stroke / 2+150 or Stroke / 2+220 Note 1 Different retracted length is relative to different bending moment, See page 3 . Note

1 If met S>700mm & RL=S/2+150 & Bottom side cable conditions at the same

time, the minimum retracted length needs to+20mm. Cable Exit 1 = Top end socket 2 = Bottom side cable 3 = Top side cable 4 = Top (to TC) + Bottom (to TH) side cable Socket

Functions for Limit Switches Wire Definitions CODE Pin 1 (Green) 2 (Red) 3 (White) 4 (Black) 5 (Yellow) 6 (Blue) 1 extend (VDC+) N/A N/A N/A retract (VDC+) N/A 3 extend (VDC+) common upper limit switch N/A retract (VDC+) lower limit switch 1 = DIN 6P , socket (Top end socket) G = Molex 8P 90° 1 = DIN 6P , 90° plug (Side cable) H = Molex 8P 180° 2 = Tinned leads 2 = DIN 6P , socket, F = DIN 6P , 180° plug C = Direct cut, water proof, anti-pull Connector For TH: long DIN 5P (Pin array 240°), 180° socket (with anti-pull clip) For Columm 2: long DIN 6P (Pin array 240°), 180° plug (with anti-pull clip) For TP: long DIN 5P (Pin array 240°), 180° plug (with O-ring) Cable Exit C = Bottom side - Y cable, for TH + TPB = Top side - for TH; Bottom side - for TP D = Top side - for the 2nd column; Bottom side - for TH & TP; direct cut operation with 2 columns E = Top side - for the 2nd column & TH; Bottom side - for TP; direct cut operation with 2 columns

Cable Length (mm) Tubes Direction B = Cable exit #B, L2 = L3 = 100 0 = Thinner on top 1 = Wider on top C = Cable exit #C, L1 = L2 = L3 = 100 D, E = Cable exit #D, #E, L2 = L3 = L4 = 100 L2 L1 TH TP TL3 L3L2 THTP Terms of Use The user is responsible for determining the suitability of TiMOTION products for a specific application. TiMOTION products are subject to change without prior notice. L3L2 TH Column 2TP