Tfs300.doc version 1.3 28.03.2001 VI TELEFILTER Filter Specification TFS 300 VI TELEFILTER Vectron International Inc. Potsdamer Straße 18

267 Lowell Road

Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Measurement condition Ambient temperature: Input power level: dBm Terminating impedances for input: 607 Ω // - 1,7 pF for output: 607 Ω // - 1,7 pF External coil: 122 nH Characteristics Remark: Reference level for the relative attenuation arel of the TFS 300 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 300,0 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. D a t a typ. value tolerance/limit Insertion loss ae = amin max. 6,5 dB (Reference level) Nominal frequency fN 300,000 MHz Centre frequency fC 300,01 Usable signal bandwidth min. 140 kHz 3 dB bandwidth BW min. 280 kHz Relative attenuation arel fN ± 400 kHz min. 15 dB fN ± 400 kHz ... fN ± 600 kHz min. 27 dB fN ± 600 kHz ... fN ± MHz min. 35 dB Group delay ripple GD fN ± kHz max. µs Operating temperature range -20 °C ... +70 °C Temperature coefficient of frequency TC -0.036 ppm/K² Frequency inversion temperature + 20 Generated: Checked / approved:

Tfs300.doc version 1.3 28.03.2001 VI TELEFILTER Filter Specification TFS 300 VI TELEFILTER Vectron International Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Construction, pin configuration and 50 ΩΩΩΩ - matching network (All dimensions in mm) S 300 N12 Date code 5.0 SQ +0.15 -0.1 Pin 1 Output Pin 5 Input Pin 2 Ground Pin 6 Ground Pin 3 External Coil Pin 7 Ground Pin 4 Package Ground Pin 8 Package ground

50 Ohm Test circuit 1

2, 4, 5, 7, 8

50 Ohm

50 Ohm Test circuit 2

2, 4, 6, 7, 8 Datecode: Year+week L 1999 M 2000 N 2001 ...

Tfs300.doc version 1.3 28.03.2001 VI TELEFILTER Filter Specification TFS 300 VI TELEFILTER Vectron International Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration:

10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;

  1. Damp heat: 25 °C to 55°C / 95% r.H. / 10 cycles (cycle) DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 3000 reel of empty components at start: min 300 mm reel of empty components at start including leader: min 500 mm trailer min 300 mm Do Po E F W EMBOSSED CARRIER TAPE COVER TAPE G P 2 Bo A o CT D 1 Tape (all dimensions in mm) W : 12 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,1 E : 1,75 ± 0,1 F : 5,5 ± 0,05 G (min) : 0,75 P2 : 2 ± 0,05 P1 : 8 ± 0,1 D1(min) : 1,5 Ao : 5,3 ± 0,1 Bo : 5,3 ± 0,1 CT : 9,5 ± 0,1 A C N W 1 W 2 Reel (all dimensions in mm): A : 330 W1 : 12,4 + 0,2 W2 (max) : 18,4 N (min) : 50 C : 13 ± 0,2 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape.

Tfs300.doc version 1.3 28.03.2001 VI TELEFILTER Filter Specification TFS 300 VI TELEFILTER Vectron International Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods main-heating periods peak temperature Temperature: 150 °C - 170 °C over 200 °C 255 °C ± 5 °C Time: 60 sec. - 90 sec. 20 sec. - 25 sec. Chip-mount air reflow profile time / sec. temperature / °C 100 120 140 160 180 200 220 240 260 100 120 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. temperature / °C time / sec. temperature / °C 140 160 150 161 160 164 170 170 180 180 103 190 205 121 195 230 134 200 255 143 205 230 150 210 205 100 154 215 180 110 156 220 165 120 158 230 140 130 159 240 120

Tfs300.doc version 1.3 28.03.2001 VI TELEFILTER Filter Specification TFS 300 VI TELEFILTER Vectron International Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. History Version Reason of Changes Name Date 1.3 Add History. Dr. Wall 28.03.2001 Change date code from month to week. Correct tape and reel information. Use harder test conditions for point stability characteristic.