TFS256 VECTRON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Filename: tfs 256.doc Version 1.1 28.11.2005 VI TELEFILTER Filter specification TFS 256 1/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Measurement condition Ambient temperature: 23 °C Input power level: 0 dBm Terminating impedance: Input: 200 Ω Output: 200 Ω Characteristics Remark: The nominal frequency fN is fixed at 256,0 MHz. The in sertion loss ae is defined as lo ss value determined at fN. All specified data are me t within the operating temperature range. D a t a typ. value tolerance / limit Insertion Loss ae 1,35 dB max. 3,5 dB (reference level) Nominal Frequency fN - 256,0 MHz Centre Frequency fC 256,0 MHz Bandwidth BW 3 dB 5,85 MHz - Absolute Attenuation aabs fN - 85,333 MHz 53 dB min. 48 dB fN + 85,333 MHz 48 dB min. 45 dB fN ± 170,666 MHz 51 dB min. 48 dB fN + 256,000 MHz 51 dB min. 48 dB Input power level max. 10 dBm Operating Temperature Range OTR - - 25 °C ... + 85 °C Storage Temperature Range - - 45 °C ... + 95 °C Temperature Coefficient of Frequency TCf * - 32 ppm/K *) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz). Generated: Checked / Approved: VI TELEFILTER reserves the right to make chang es to the produc t(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.

Filename: tfs 256.doc Version 1.1 28.11.2005 VI TELEFILTER Filter specification TFS 256 2/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Filter characteristic 0 100 200 300 400 500 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 frequency in M Hz magnitude in dB 252 253 254 255 256 257 258 259 -4.5 -3.5 -2.5 -1.5 -0.5 frequency in M Hz magnitude in dB 252 253 254 255 256 257 258 259 Construction and pin connection (All dimensions in mm)

1 Ground

2 Input

3 Ground

4 Ground

5 Ground

6 Output

7 Ground

8 Ground

SQ 3,81 +0,2/-0,1 1 3 7 5 1,2 Max.0,6 1,78 0,1 1,78 2,54 120%%d 256

  • T48 Date code: Year + week T 2005 U 2006 V 2007 ... 200 Ω Test circuit SAW 1, 3, 4, 5, 7, 8 6 2 VI TELEFILTER reserves the right to make chang es to the produc t(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.

Filename: tfs 256.doc Version 1.1 28.11.2005 VI TELEFILTER Filter specification TFS 256 3/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: 3000 reel of empty components at start: min. 300 mm reel of empty components at start including leader: min. 500 mm trailer: min. 300 mm G Do W Ct F E G Po Bo Ao Pull Off Direction PIN MarkerTyp Date Code Ko t Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 4,30 ± 0,1 Bo : 4,30 ± 0,1 Ct : 9,5 ± 0,1 A C N W 1 W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 The minimum bending radius is 45 mm. VI TELEFILTER reserves the right to make chang es to the produc t(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.

Filename: tfs 256.doc Version 1.1 28.11.2005 VI TELEFILTER Filter specification TFS 256 4/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Air reflow temperature conditions Conditions Exposure Average ramp-up rate (30°C to 217°C) less than 3°C/second > 100°C between 300 and 600 seconds > 150°C between 240 and 500 seconds > 217°C between 30 and 150 seconds Peak temperature max. 260°C Time within 5°C of actual peak temperature between 10 and 30 seconds Cool-down rate (Peak to 50°C) less than 6°C/second Time from 30°C to Peak temperature no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C Time / s max. 300 s 10 ... 30 s 30 ... 150 s VI TELEFILTER reserves the right to make chang es to the produc t(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.

Filename: tfs 256.doc Version 1.1 28.11.2005 VI TELEFILTER Filter specification TFS 256 5/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 25.08.2005 1.1 - Add typical values, add filter characteristic, Channaa 28.11.2005 - change absolute attenuation, change stability characteristics, - generation of filter specification VI TELEFILTER reserves the right to make chang es to the produc t(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.