tfs 140A1.doc Version 1.4 18.07.2000 VI TELEFILTER Filter Specification TFS 140A1 - 1/5 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18

267 Lowell Road

Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 1. Measurement condition Ambient temperature TA: 23 °C Input power level: 0 dBm. Terminating impedances at fc: for input: for output: Q-value of matching elements: 2. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 140A1 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme Data typ. value tolerance / limit Insertion loss (Reference level) ae 18,5...19,0 dB max. dB Centre frequency fc at ambient temperature TA (fCAT) 140,01 MHz 140 ± 0,06 MHz Pass band at ambient temperature TA: Amplitude ripple (p-p): fC ... fC ± 1,35 MHz 0,5 dB fC ± 1,35 MHz fC ± 1,42 MHz 0,7 dB Bandwidth at ambient temperature: 1,0 dB - band width 2,88 MHz dB - band width 3,15 MHz min. 3,10 MHz dB - band width 3,83 MHz dB - band width 4,20 MHz max. 4,60 MHz dB - band width 4,24 MHz max.11,88 MHz Relative attenuation arel fC fC ± 1,55 MHz max. dB fC ± 2,30 MHz fC ± 5,94 MHz 45...55 dB min. dB fC ± 5,94 MHz fC ± 40 MHz 60....70 dB min. dB Group delay ( mean value in pass band ): 2,49 µs max. 2,5 µs Group delay ripple in pass band (p-p): 140...170 ns max. 200 ns Deviation from linear phase in pass band (p-p): max. 10° Input VSWR (S11) in PB : 1,3 : 1 max. 2 : 1 Output VSWR (S22) in PB : 1,4 : 1 max. 2 : 1 Triple transit attenuation compared to main signal 41...42 dB min. dB Crosstalk 52...55 dB Substrate material Quartz Frequency inversion temperature ( To ) 25° C Temperature coefficient of frequency ( Tcf ) -0,045 ppm/K² Frequency deviation of fc over temperature: * ) ∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz) Operating temperature range 0 °C ... + 70 °C Storage temperature range * ) fTo is reference frequence fc at frequency inversion temperature (To ) Generated: Dunzow W.P. Checked/Approved: Dr. Bert Wall

tfs 140A1.doc Version 1.4 18.07.2000 VI TELEFILTER Filter Specification TFS 140A1 - 2/5 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 3. Package 4. 50 ΩΩΩΩ matching network ( see Application Note ): L2 = 165 ± 10 nH L4 = 120 nH; R2 = 1,8 kΩ; L3 = 120 nH; R1 = 1,8 kΩ; = 188 ± 10 nH 50 Ω 1 2 3 4 5 10 9 8 7 6 TFS 140A1 . M22 50 Ω TFS 140 G1 M19 TFS 140A1 . M22 Datecode: Year+week K 1998 L 1999 M 2000 Pin 10 Input Pin 1 Input RF Return Pin 5 Output Pin 6 Output RF Return Pin 2 - 4, 7 - 9 Package Ground

tfs 140A1.doc Version 1.4 18.07.2000 VI TELEFILTER Filter Specification TFS 140A1 - 3/5 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 5. Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration:

10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;

  1. Damp heat: 25 °C to 55°C / 95% r.H. / 10 cycles (cycle) DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; 6. Packing Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 2000 Real of empty components at start: min 300 mm Real of empty components at start including leader: min 500 mm Trailer min 300 mm Reel (all dimensions in mm): A : 330 W1 : 32,4 +2 W2 (max) : 38,4 N (min) : 100 C : 13 +0,5/-0,2 A C N W W The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. D o P o E F W P 1 EMBOSSED CARRIER TAPE COVER TAPE G P 2 B o A o CT D 1 Tape (all dimensions in mm) W ± 0,3 Po ± 0,1 Do 1,5 + 0,1 E 1,75 ± 0,1 F 14,2 ± 0,1 G (min) : 0,6 ± 0,1 ± 0,1 D1(min) : 2,0 Ao 7,1 ± 0,1 Bo 19,6 ± 0, t 0,3 ± 0,05 CT 25,5 ± 0,1

tfs 140A1.doc Version 1.4 18.07.2000 VI TELEFILTER Filter Specification TFS 140A1 - 4/5 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 7. Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods main-heating periods peak temperature Temperature: 150 °C - 170 °C over 200 °C 255 °C ± 5 °C Time: 60 sec. - 90 sec. 20 sec. - 25 sec. Air reflow profile 100 120 140 160 180 200 220 240 260 100 120 140 160 180 200 220 240 time / sec. temperature / °C Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. temperature / °C time / sec. temperature / °C 140 160 150 161 160 164 170 170 180 180 103 190 205 121 195 230 134 200 255 143 205 230 150 210 205 100 154 215 180 110 156 220 165 120 158 230 140 130 159 240 120

tfs 140A1.doc Version 1.4 18.07.2000 VI TELEFILTER Filter Specification TFS 140A1 - 5/5 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. History Version Reason of Changes Name Date 1.0 Generate specification according to customer requirements. Dunzow W. 15.05.2000 1.1 Add theoretical matching network scheme. Dunzow W. 31.05.2000 Change filter name from TFS 140A11 to TFS 140A1 Change input and output pin positions according to customer requirements. 1.2 Correct errors in matching network scheme. Dunzow W. 05.06.2000 1.3 Change limit value ILo : from ILo = max. 19 dB to ILo = max. 20 dB Dunzow W. 22.06.2000 Correct wrong unit for limit value of TTS ( ns → dB ). Add VSWR according to customer requirement. 1.4 Edit typical values after measured. Dunzow W. 18.07.2000 Edit termination impedances .