TFS 135C.doc version 2.0 22.03.01 VI TELEFILTER Filter Specification TFS 135 C VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18

267 Lowell Road

Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information 1. Measurement condition Ambient temperature TA: 23 °C Input power level: dBm Terminating impedances at fc: for input: for output: 2. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 135C is the insertion loss. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. Data typ. value tolerance / limit Insertion loss (Reference level) ae 14,6 dB max 15,5 dB Centre frequency fc 135,420 MHz ± 60 kHz Relative attenuation arel fc ± 1,25 MHz max dB fc ± MHz fc ± 15 MHz 45...48 dB min dB fc ± MHz fc ± 25 MHz 50...60 dB min dB Group delay ripple: fc ± 1,0 MHz 80 ns Temperature coefficient of frequency ( Tcf ) -19 ppm/K Frequency deviation of fc over temperature T: ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz) Operating Temperature Range - 10 °C ... + 85 Checked/Approved:

TFS 135C.doc version 2.0 22.03.01 VI TELEFILTER Filter Specification TFS 135 C VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information 3. Construction, pin configuration and 50 ΩΩΩΩ - matching network (All dimensions in mm) S 135C N06 50 ΩΩΩΩ test circuit IN OUT SAW Datecode Year+week L 1999 M 2000 N 2001 ... Ground Ground Output Ground Ground Ground Ground Ground Input Ground Ground Ground

TFS 135C.doc version 2.0 22.03.01 VI TELEFILTER Filter Specification TFS 135 C VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information 4. Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration:

10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;

  1. Damp heat: 25 °C to 55°C / 95% r.H. / 10 cycles (cycle) DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; 5. Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 2000 Reel of empty components at start: min 300 mm Reel of empty components at start including leader: min 500 mm Trailer min 300 mm D o Po E F W EMBOSSED CARRIER TAPE COVER TAPE G P 2 Bo A o CT D 1 Tape (all dimensions in mm) W : 16 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,1 E : 1,75 ± 0,1 F : 7,5 ± 0,1 G (min) : 0,6 P2 : 2 ± 0,1 P1 : 8 ± 0,1 D1(min) : 1,5 Ao : 5,5 ± 0,1 Bo : 7,5 ± 0,1 CT : 13,5 + 0,1 A C N W 1 W 2 Reel (all dimensions in mm): A : 330 W1 : 16,4 +2 W2 (max) : 22,4 N (min) : 50 C : 13 +0,5 / -0,2 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is readable if the sprocket holes are on the left side of the tape, i.e. pin 1 identifier is close to the sprocket holes.

TFS 135C.doc version 2.0 22.03.01 VI TELEFILTER Filter Specification TFS 135 C VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information 6. Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods main-heating periods peak temperature Temperature: 150 °C - 170 ° Cover 200 °C 255 °C ± 5 °C Time: 60 sec. - 90 sec. 20 sec. - 25 sec. Air reflow profile 100 120 140 160 180 200 220 240 260 100 120 140 160 180 200 220 240 time / sec. temperature / °C Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. temperature / °C time / sec. temperature / °C 140 160 150 161 160 164 170 170 180 180 103 190 205 121 195 230 134 200 255 143 205 230 150 210 205 100 154 215 180 110 156 220 165 120 158 230 140 130 159 240 120

TFS 135C.doc version 2.0 22.03.01 VI TELEFILTER Filter Specification TFS 135 C VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information 7. History Version Reason of Changes Name Date 1.0 - generate specification Pfeiffer 09.02.01 2.0 - new definition of insertion loss (minimum of the passband attenuation) Pfeiffer 22.03.01 - new teminating impedances at fC - fC = 135,420 MHz ± 60 kHz - change from nominal frequency to centre frequency as basis for relative attenuation - ae = 15,5 dB - group delay ripple = 80 ns