File name: Tfs133.doc version 1.4 10.10.2001 VI TELEFILTER Filter Specification TFS 133 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18
267 Lowell Road
Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Measurement condition : Ambient temperature TA: Input power level: dBm Terminating impedances in fc *) : for input: 1656 ΩΩΩΩ - 7,292 pF. for output: 2084 ΩΩΩΩ - 6,964 pF. Characteristics : Remark: Reference level for the relative attenuation arel of the TFS 133 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The nominal frequency fN is fixed to 133.0 MHz. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. All specified parameters have to be reached in the operating temperature range ( OTR ) . Data typ. value tolerance / limit Insertion loss (Reference level) ae 7,2...8,2 * ) dB max. dB Nominal frequency fN 133 MHz Centre frequency fc in OTR 133± 0,025 MHz Centre frequency fc at ambient temperature TA = 23 °C 133,007 MHz 133,007± 0,018MHz Amplitude ripple in fN ± 80 kHz (p-p): max. 0,2 dB Amplitude ripple in fN ± 200 kHz (p-p): max. 0,4 dB Bandwidth in OTR : 0,2 dB - band width 350...400 kHz min. 0,16 MHz 0,4 dB - band width 500...580 kHz min. 0,40 MHz dB - band width 2720 kHz max. 3,6 MHz Relative attenuation arel fN kHz 0,1 dB max. 0,2 dB fN ± kHz .... fN ± 200 kHz 0,2 dB max. 0,4 dB fN ± 1,8 MHz .... fN ± MHz dB min. dB fN ± MHz .... fN ± MHz dB min. dB fN - 132 MHz .... fN - MHz dB min. dB fN + MHz .... fN + 887 MHz 70...50 dB min. dB Group delay ( mean value) fN ± 50 kHz 0,78 µs max. µs Group delay ripple fN ± 50 kHz (p-p) ns max. µs Return loss with matching network (S11 / S22 ) in fN ± 100 kHz: dB min. dB Input power level max. dBm Frequency inversion temperature ( To ) : 37 ° C Temperature coefficient of frequency ( Tcf ) : - 0,036 ppm/K² Frequency deviation of fc over temperature: ** ) ∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fO (MHz) Operating temperature range ( OTR ) : - 5 °C ... + 80 °C Storage temperature range : *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) fO = fTo is reference frequency fc at frequency inversion temperature (To ) Generated: Wadim Dunzow Checked/Approved:
File name: Tfs133.doc version 1.4 10.10.2001 VI TELEFILTER Filter Specification TFS 133 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 3. Construction and Pin Connection (All dimensions in mm) TFS 133 N40 4. 50 ΩΩΩΩ matching network ( about matching element values see Application Note.) : For final test we use scheme 1. Datecode: Year+week L 1999 M 2000 N 2001 ... ... Pin 9 Input. Pin 10 Input RF Return. Pin 4 Output. Pin 5 Output RF Return. Pin 1-3, 6-8 - PackageGround. 8 7 6 1 2 3 Scheme 1 50 ΩΩΩΩ 50 ΩΩΩΩ 8 7 6 1 2 3 50 ΩΩΩΩ 50 ΩΩΩΩ Scheme 2
File name: Tfs133.doc version 1.4 10.10.2001 VI TELEFILTER Filter Specification TFS 133 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
- Change of temperature -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow):max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; 6. Packing : Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 3000 reel of empty components at start: min 300 mm reel of empty components at start including leader: min 500 mm trailer min 300 mm The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. A C N W 1 W Reel (all dimensions in mm): A 330 24,4 +2,0 W2(max) : 30,4 N(min) C 13 +0,5/-0,2 D o P o E F W P 1 EMBOSSED CARRIER TAPE COVER TAPE G P 2 B o A o CT D 1 Tape (all dimensions in mm) W 24± 0,3 Po ± 0,1 Do 1,5 + 0,1 E 1,75 ± 0,1 F 11,5 ± 0,1 G (min) 0,6 ± 0,1 ± 0,1 D1(min) : 1,5 Ao 5,6 ± 0,1 Bo 11,8 ± 0,1 CT 21,5 ± 0,1
File name: Tfs133.doc version 1.4 10.10.2001 VI TELEFILTER Filter Specification TFS 133 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 7. Air reflow temperature conditions : 1st and 2nd air reflow profile Name: pre-heating periods main-heating periods peak temperature Temperature: 150 °C - 170 °C over 200 °C 255 °C ± 5 °C Time: 60 sec. - 90 sec. 20 sec. - 25 sec. Chip-mount air reflow profile time / sec. temperature / °C 100 120 140 160 180 200 220 240 260 100 120 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. temperature / °C time / sec. temperature / °C 140 160 150 161 160 164 170 170 180 180 103 190 205 121 195 230 134 200 255 143 205 230 150 210 205 100 154 215 180 110 156 220 165 120 158 230 140 130 159 240 120
File name: Tfs133.doc version 1.4 10.10.2001 VI TELEFILTER Filter Specification TFS 133 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 8. History : Version Reason of Changes Name Date 1.0 Generation of specification according to customer requirements. M. Senior 18.05.2001 1.1 Add maximum value for insertion loss of 9 dB. Dr. Wall 01.06.2001 Correct tape and reel information. 1.2 Change package. Dunzow W. 21.06.2001 Add possible configuration of matching networks. Change definition of centre frequency : from 3 dB to 20 dB ( see : 2. “Characteristics - Remark ” ) 1.3 Add requirement for ILo in OTR. Dunzow W. 09.07.2001 Correct OTR according to customer requirements. Correct frequency range for return loss . 1.4 - add typical values of filter and termination impedances; Dunzow W. 10.10.2001 - change name of specification : from “Preliminary specification” to “Filter specification”.
Filename: tfs133.doc Directory: R:\\info\\global\\spezifikationen Template: C:\\Program Files\\Microsoft Office\\Templates\\Normal.dot Title: Measurement condition Subject: Author: Dr. Wall Keywords: Comments: Creation Date: 10/08/01 6:47 PM Change Number: Last Saved On: 09/26/02 3:09 PM Last Saved By: Authorized User Total Editing Time:
1 Minute
Last Printed On: 10/01/02 8:59 AM As of Last Complete Printing Number of Pages: Number of Words: 800 (approx.) Number of Characters: 4,560 (approx.)