DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Filename: tfs 1204.doc Version 1.4 12.03.2008 VI TELEFILTER Filter specification TFS 1204 1/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@vectron.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Measurement condition Ambient temperature: 23 ° C Input power level: 0 dBm Terminating impedance: Input: 50 Ω Output: 50 Ω Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss a e. The nominal frequency fN is fixed at 1204,0 MHz without any tolerance or limit. The values of absolute attenuation a abs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the op erating temperature range is included in the production tolerance scheme. D a t a typ. value tolerance / limit Insertion loss ae 4,3 dB max. 5,0 dB Nominal frequency fN - 1204,0 MHz Passband PB - f N ± 47,5 MHz Pass band variation 2,2 dB max. 3,0 dB Absolute attenuation aabs 0,3 MHz … 1000 MHz 25 dB min. 23 dB 1297 MHz … 2000 MHz 28 dB min. 25 dB Group delay ripple within PB 7 ns max. 20 ns Input power level - max. 12 dBm Operating temperature range OTR - - 20 ° C ... + 80° C Storage temperature range - - 45 ° C ... + 85° C Temperature coefficient of frequency TC f * - 72 ppm/K - *) ∆f(Hz) = TC f(ppm/K) x (T-T0) x f To (MHz) Generated: Checked / Approved:

Filename: tfs 1204.doc Version 1.4 12.03.2008 VI TELEFILTER Filter specification TFS 1204 2/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@vectron.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filter characteristic Construction and pin connection (All dimensions in mm) 1 2 3 456 1,2 Max. 0,6 0,1 0,75 3 ±0,15 0,6 1,5 1 3 6 4 Date code 50 Ω Test circuit SAW L2 2 5 1, 3, 4, 6 C04

  • W11

1 Ground

2 Input

3 Ground

4 Ground

5 Output

6 Ground

Date code: Year + week W 2008 X 2009 A 2010 ... -90 -80 -70 -60 -50 -40 -30 -20 -10 frequency in MHz magnitude in dB 1134 1148 1162 1176 1190 1204 1218 1232 1246 1260 1274 -12 -10.8 -9.6 -8.4 -7.2 -4.8 -3.6 -2.4 -1.2 frequency in MHz magnitude in dB 1134 1148 1162 1176 1190 1204 1218 1232 1246 1260 1274 -0.015 0.015 0.03 0.045 0.06 0.075 0.09 0.105 0.12 0.135 frequency in MHz delay in µs

Filename: tfs 1204.doc Version 1.4 12.03.2008 VI TELEFILTER Filter specification TFS 1204 3/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@vectron.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respe ctively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 ° C to 125° C / 30 min. each / 1 0 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: three ti mes max.; for temperature conditions refer to the attached " Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value f or N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 9000 reel of empty components at start: min. 300 mm reel of empty components at start including leader : min. 500 mm trailer: min. 300 mm G Do W Ct F E G Po Bo Ao Pull Off Direction PIN Marker Typ Date Code Ko t A C N W 1 W 2 The minimum bending radius is 45 mm. Tape (all dimensions in mm) W : 8,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 3,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 4,00 ± 0,1 D1(min) : 1,50 Ao : 3,25 ± 0,1 Bo : 3,25 ± 0,1 Ct : 5,5 ± 0,1 Reel (all dimensions in mm) A : 330 W1 : 8,4 +1,5/-0 W2(max) : 14,4 N(min) : 50 C : 13,0 +0,5/-0,2

Filename: tfs 1204.doc Version 1.4 12.03.2008 VI TELEFILTER Filter specification TFS 1204 4/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@vectron.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Air reflow temperature conditions Conditions Exposure Average ramp-up rate (30° C to 217° C) less than 3° C/ second > 100° C between 300 and 600 seconds > 150° C between 240 and 500 seconds > 217° C between 30 and 150 seconds Peak temperature max. 260° C Time within 5° C of actual peak temperature between 10 and 30 seconds Cool-down rate (Peak to 50° C) less than 6° C/second Time from 30° C to Peak temperature no greater than 300 seconds Temperature / ° C Time / s max. 260° C 217° C 10 ... 30 s 30 ... 150 s max. 300 s Chip-mount air reflow profile

Filename: tfs 1204.doc Version 1.4 12.03.2008 VI TELEFILTER Filter specification TFS 1204 5/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@vectron.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 20.02.2006 1.1 - Change operating temperature range Noack 09.10.2006 1.2 - Change/ relax group delay ripple and attenuat ion Noack 28.11.2006 1.3 - Change OTR Strehl 03.09.2007 - Add typ. value and filter characteristic - Generation of filter specification 1.4 - change pass band definition S.Springfeldt 12.03.2008 - change operating temperature range - change of typical values