TFS110P VECTRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
file: tfs110p.doc version 2.1 05.01.02 VI TELEFILTER Filter specification TFS 110P 1/4 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18
267 Lowell Road
Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Measurement condition Ambient temperature: 23°C Input power level: 0 dBm Terminating impedances for input: 2,9 kΩ || -6.2 pF for output: 2,8 kΩ || -5.5 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 110 P is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 30 dB filter attenuation level relative to the insertion loss ae. D a t a typ. value tolerance / limit Insertion loss ae = amin dB dB (reference level) Reference frequency fc (30 dB-BW) 110,592 MHz ± 60 kHz Pass band shape (3 dB-BW) Gaussian 3 dB bandwidth BW 965 kHz 10 dB bandwidth 1695 kHz 20 dB bandwidth 2255 kHz 30 dB bandwidth 2600 kHz 40 dB bandwidth 2840 kHz Relative attenuation arel fc + 475 kHz ≤ 3 dB fc - 425 kHz ≤ 3 dB fc ± 800 kHz ≤ 10 dB fc + 1200 kHz ≥ 20 dB fc - 1210 kHz ≥ 20 dB fc + 1375 kHz ≥ 30 dB fc - 1395 kHz ≥ 30 dB fc + 1500 kHz ... fc + MHz > 40 dB ≥ 35 dB fc + MHz ... fc +10 MHz > 40 dB ≥ 30 dB fc - 1535 kHz ... fc - 10 MHz > 45 dB ≥ 40 dB Group delay GD Ripple fc ± 576 kHz 250 ns max 400 ns Temperature coefficient TC 2nd order *) - 0,032 ppm/K² Frequency inversion temperature To t.b.d. Operating temperature range Storage temperature range Input power level max. + 10 dBm *) - ∆f (Hz) = TC (ppm/K²) x (T - To)² x FTo (MHz) Generated: Checked / approved:
file: tfs110p.doc version 2.1 05.01.02 VI TELEFILTER Filter specification TFS 110P 2/4 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Construction and pin connection (All dimensions in mm) S 110 P 50 ΩΩΩΩ test circuit Input
50 Ohm
1,2,3,5,6,7, 8,9,11,12 Ground Ground Output RF Return Output Ground Ground Ground Ground Input RF Return Input Ground Ground
file: tfs110p.doc version 2.1 05.01.02 VI TELEFILTER Filter specification TFS 110P 3/4 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
- Damp heat: 25 °C to 55°C / 95% r.H. / 10 cycles (cycle) DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 3000 Real of empty components at start: min 300 mm Real of empty components at start including leader: min 500 mm Trailer min 300 mm Do Po E F W EMBOSSED CARRIER TAPE COVER TAPE G P 2 Bo Ao 13,4 ± 0,1 D 1 Tape (all dimensions in mm) W : 16 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,5 E : 1,75 ± 0,1 F : 7,5 ± 0,1 G (min) : 0,75 P2 : 2 ± 0,05 P1 : 8 ± 0,1 D1(min) : 1,5 Ao : 5,4 ± 0,1 Bo : 7,4 ± 0,1 D1 : 1,5 + 0,5 A C N W 1 W 2 Reel (all dimensions in mm): A : 330 W1 : 16,4 +2 W2 (max) : 22,4 N (min) : >= 90 C : 13 ± 0,25 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape.
file: tfs110p.doc version 2.1 05.01.02 VI TELEFILTER Filter specification TFS 110P 4/4 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods main-heating periods peak temperature Temperature: 150 °C - 170 °C over 200 °C 255 °C ± 5 °C Time: 60 sec. - 90 sec. 20 sec. - 25 sec. Chip-mount air reflow profile time / sec. temperature / °C 100 120 140 160 180 200 220 240 260 100 120 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. temperature / °C time / sec. temperature / °C 140 160 150 161 160 164 170 170 180 180 103 190 205 121 195 230 134 200 255 143 205 230 150 210 205 100 154 215 180 110 156 220 165 120 158 230 140 130 159 240 120