Filename: tfs 110k2.doc Version 1.4 01.00.2006 VI TELEFILTER Filter specification TFS 110K2 1/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Measurement condition Ambient temperature: 25 °C Input power level: 0 dBm Terminating impedance: * Input: 700 Ω || -13,7 pF Output: 700 Ω || -11,6 pF Characteristics Remark: The reference level for the relativ e attenuation arel of the TFS 110K2 is the minimum of the pass band attenuation. This value is defined as the insertion loss a e. The nominal frequency f N is fix ed at 110,6 MHz w ithout any tolerance. The v alues of relativ e attenuation a rel are guaranteed for the w hole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. D a t a typ. value tolerance / limit Insertion loss ae 6,5 dB max. 9 dB (reference level) Nominal frequency fN - 110,6 MHz Passband PB - fN ± 65,0 kHz Pass band ripple 0,2 dB max. 1 dB Relative attenuation arel fN ... fN ± 65 kHz 0,5 dB max. 1 dB fN ± 65 kHz ... fN ± 82,5 kHz 0,6 dB max. 1,5 dB fN ± 400 kHz ... fN ± 800 kHz 24 dB min. 22 dB fN ± 800 kHz ... fN ± 1,6 MHz 34 dB min. 27 dB fN ± 1,6 MHz ... fN ± 10 MHz 40 dB min. 35 dB fN ± 10 MHz ... fN ± 25 MHz 50 dB min. 45 dB Group delay ripple within fN ± 80 kHz 200 ns max 500 ns Input power level max. +10 dBm Operating temperature range - - 25 °C ... + 85°C Storage temperature range - - 40 °C ... + 85°C Frequency inversion temperature 0 °C Temperature coefficient of frequency TCf ** -0,036 ppm/K *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K2) x (T-T0)² x fTo(MHz). Generated: Checked / Approved: VI TELEFILTER reserves the right to make changes to the produc t(s) and/or information contained herein w ithout notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 110k2.doc Version 1.4 01.00.2006 VI TELEFILTER Filter specification TFS 110K2 2/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Filter characteristic -90 -80 -70 -60 -50 -40 -30 -20 -10 frequency in MHz magnitude in dB frequency in MHz magnitude in dB 2.42 2.84 3.26 3.68 4.1 4.52 4.94 5.36 5.78 frequency in MHz delay in µs Construction and pin connection Date code: Year + week U 2006 V 2007 W 2008 ...
1 Ground
2 Ground
3 Ground
4 Ground
5 Output
6 Output
7 Ground
8 Ground
9 Ground
10 Ground
11 Input
12 Input
(All dimensions in mm) 13,6Max. 6,8Max. 2,0Max. 8910 1,5 2,54 ±0,15 2,54 ±0,15 0,8 0,1 1 2 3 4 Date code TFS 110K2
- U35 50 Ω Test circuit SAW 5 11 VI TELEFILTER reserves the right to make changes to the produc t(s) and/or information contained herein w ithout notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 110k2.doc Version 1.4 01.00.2006 VI TELEFILTER Filter specification TFS 110K2 3/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 1700 reel of empty components at start: min. 300 mm reel of empty components at start including leader: min. 500 mm trailer: min. 300 mm G Do W Ct F E G Po Bo Ao Pull Off Direction PIN MarkerTyp Date Code Ko t Tape (all dimensions in mm) Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,10 F : 11,50 ± 0,10 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 Ao : 7,10 ± 0,10 Bo : 13,90 ± 0,10 Ct : 21,5 ± 0,1 A C N W 1 W 2 Reel (all dimensions in mm) A : 330 W1 : 24,4 +2/-0 W2(max) : 30,4 N(min) : 60 C : 13,0 +0,5/-0,2 The minimum bending radius is 45 mm. VI TELEFILTER reserves the right to make changes to the produc t(s) and/or information contained herein w ithout notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 110k2.doc Version 1.4 01.00.2006 VI TELEFILTER Filter specification TFS 110K2 4/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Air reflow temperature conditions Conditions Exposure Average ramp-up rate (30°C to 217°C) less than 3°C/second > 100°C between 300 and 600 seconds > 150°C between 240 and 500 seconds > 217°C between 30 and 150 seconds Peak temperature max. 260°C Time within 5°C of actual peak temperature between 10 and 30 seconds Cool-down rate (Peak to 50°C) less than 6°C/second Time from 30°C to Peak temperature no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C Time / s max. 300 s 10 ... 30 s 30 ... 150 s VI TELEFILTER reserves the right to make changes to the produc t(s) and/or information contained herein w ithout notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 110k2.doc Version 1.4 01.00.2006 VI TELEFILTER Filter specification TFS 110K2 5/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com History Version Reason of Changes Name Date 1.0 generate specification according to customer requirements Pfeiffer 06.06.2001 1.1 density parameter added Pfeiffer 26.10.2001 1.2 remove AC voltage specification Steiner 21.11.2001 1.3 change construction Strehl 24.08.2006 1.4 add typical values Alawneh 01.09.2006 add filter characteristics VI TELEFILTER reserves the right to make changes to the produc t(s) and/or information contained herein w ithout notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.