TFH36A VECTRON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

File name : TFH36A.doc Version 1.0 13.03.2001 VI TELEFILTER Filter Specification TFH 36A VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18

267 Lowell Road

Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com Email: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 1. Measurement condition Ambient temperature TA: 25 °C Input power level: 0 dBm. Terminating impedances at fc: for input: 50 Ω  0 pF. for output: 50 Ω  0 pF. 2. Characteristics Remark: The insertion loss ae is defined as the insertion loss at the nominal frequency fN . Reference level for the relative attenuation arel of the TFS 36A is the insertion loss. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the centre frequency fc and the frequency response of the filter in the operating temperature range. Data typical values tolerance / limit Insertion loss (Reference level) ae 26,7 dB max. 27,5 dB Nominal frequency fN 36,125 MHz Centre frequency fC 36,125 MHz Pass band (PB) : fC ... fC ± 2,8 MHz Amplitude ripple in PB (p-p) : 0,25 dB max. 0,55 dB Bandwidth at ambient temperature: 0,55 dB - band width 7,45 MHz min. 5,6 MHz dB - band width 7,63 MHz dB - band width 8,08 MHz min. 8,0 MHz dB - band width 9,35 MHz dB - band width 9,80 MHz max. 10,0 MHz Relative attenuation arel fN ... fN ± 2,80 MHz 0,25 dB max. 0,55 dB fN ± 2,80 MHz ... fN ± 4,0 MHz < 2,6 dB max. dB fN ± 5,0 MHz ... fN ± MHz 40...45 dB min. dB Group delay ( mean value in PB ) 1,45 µs max. µs Group delay ripple in fN ... fN ± 2,8 MHz (p-p) *) ns max. ns Deviation from linear phase in fN ... fN ± 2,8 MHz (p-p) max. 3 ° Triple transit attenuation compared to main signal dB Crosstalk dB Temperature coefficient of frequency ( Tcf ) - 75 ppm/K Frequency deviation of fN over temperature : ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fN (MHz) Operating temperature range 25 °C Storage temperature range * ) measured with smoothing aperture of 120 kHz. Generated: Dunzow W.P. Checked/Approved: Dr. Bert Wall

File name : TFH36A.doc Version 1.0 13.03.2001 VI TELEFILTER Filter Specification TFH 36A VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com Email: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 3. Package : (All dimensions in mm) pin grid 2,54 mm 4. 50 ΩΩΩΩ matching networks : 1.02

2.62 Max

1.02 2.31 4.83 x 3.53 1.91 24.64 9.00 TFH 36A N07 Datecode: Year+week L 1999 M 2000 N 2001 Pin 10 Input Pin 1 Input RF Return Pin 5 Output Pin 6 Output RF Return Pin 2-4, 7-9 Package Ground 50 ΩΩΩΩ 50 ΩΩΩΩ

File name : TFH36A.doc Version 1.0 13.03.2001 VI TELEFILTER Filter Specification TFH 36A VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com Email: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration:

10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;

  1. Damp heat: 25 °C to 55°C / 95% r.H. / 10 cycles (cycle) DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; 6. Packing : Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 1000 reel of empty components at start: min 300 mm reel of empty components at start including leader: min 500 mm trailer min 300 mm Reel (all dimensions in mm): A 330 W2 (max) N (min) 100 C 13 ± 0,2 Tape (all dimensions in mm) W ± 0,3 Po ± 0,1 Do 1,5 + 0,1 E 1,75 ± 0,1 F 20,25 ± 0,05 G (min) : 0,75 ± 0,05 ± 0,1 D1(min) : 2,0 Ao 9,3 ± 0,1 Bo 24,9 ± 0,1 CT ± 0,2 E EMBOSSED CARRIER TAPE COVER TAPE G CT Bo Ao W F N A C

File name : TFH36A.doc Version 1.0 13.03.2001 VI TELEFILTER Filter Specification TFH 36A VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com Email: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 7. Air reflow temperature conditions : 1st and 2nd air reflow profile Name: pre-heating periods main-heating periods peak temperature Temperature: 150 °C - 170 °C over 200 °C 255 °C ± 5 °C Time: 60 sec. - 90 sec. 20 sec. - 25 sec. Air reflow profile 100 120 140 160 180 200 220 240 260 100 120 140 160 180 200 220 240 time / sec. temperature / °C Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. temperature / °C time / sec. temperature / °C 140 160 150 161 160 164 170 170 180 180 103 190 205 121 195 230 134 200 255 143 205 230 150 210 205 100 154 215 180 110 156 220 165 120 158 230 140 130 159 240 120

File name : TFH36A.doc Version 1.0 13.03.2001 VI TELEFILTER Filter Specification TFH 36A VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com Email: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 8. History : Version Reason of Changes Name Date 1.0 Generate extended filter specification. Dunzow W. 09.03.2001 1.1 Correct definition of insertion loss. Dunzow / Wall 13.03.2001 Correct typical filter data. Reduce max. pass band ripple from 0,6 dB to 0,55 dB.