TEKS5412X01 TEMIC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

Features

Very high photo sensitivity Supply voltage range 4.5 to 16 V Low current consumption ( 2 mA ) Side view plastic package with lens Angle of half sensitivity ϕ = ± 30 TTL and CMOS compatible Open collector output Output signal inverted ( active “low” ) Case compatible with TSKS5412 Option X01: High rel. device for advanced

applications

Taped and reeled according to IEC 286 part 2 Packing AMMOPACK: 2,000 pcs Visual inspection according to QSV 5610 14 355 Absolute Maximum Ratings Tamb = 25C Parameter Test Conditions Symbol Value Unit Supply Voltage VS1 V Output Current Io mA Power Dissipation PV 100 mW Junction Temperature Tj 100 C Operating Temperature Range Tamb –40...+85 C Storage Temperature Range Tstg –40...+100 C Soldering Temperature t 5 s, 2 mm from body Tsd 260 C Handling Precautions Connect a capacitor C of 100 nF between VS1 and ground !

Rev. A7, 13-Oct-98 2 (6) Basic Characteristics Tamb = 25C Parameter Test Conditions Symbol Min Typ Max Unit Supply Voltage VS1 4.5 V Supply Current VS1 = 16 V IS1 mA Irradiance for Threshold ”On” =950nm, VS1=5V Eeon W/cm2 Hysteresis VS1 = 5 V Eeoff/Eeon Angle of Half Sensitivity ϕ ±30 deg Wavelength of Peak Sensitivity p 920 nm Range of Spectral Bandwidth 0.5 600... 1020 nm Output Voltage IOL=16mA, VS1=5V, Ee ≥ Eon VOL 0.2 0.4 V High Level Output Current VS1=VS2=16V, IF=0 IOH A Switching Characteristics Tamb = 25C Parameter Test Conditions Symbol Min Typ Max Unit Rise Time VS1=VS2=5V, RL=1k tr 100 ns Fall Time Ee=3*Eeon, =950nm tf ns Turn–On Time ton 1.5 s Turn–Off Time toff s Switching Frequency fsw 200 kHz Additional Tests 100% inspection of body with infrared camera. test criteria: no cracks allowed 100% functional test at Tamb = –40°C test criteria: VOL > 4 V at Ee = 0 TSKS5412X01 / TEKS5412X01 matched (for Reference only) Parameters Test Conditions Symbol Min. Typ. Max. Unit Input threshold current VS1 = 5 V IFT 1.5 mA Hysteresis VS1 = 5 V IFoff/IFon Output voltage IOL = 16 mA, IF > IFT VS1 = 5 V 0.2 0.4 V Switching frequency IF = 3 x IFT, RL = 1 k VS1 = VS2 = 5 V fsw 200 kHz Electrical setup VS2 = 5 V, tp > 40 s, T > 50 ns s Remark: Parameter tested with test fixture provided by Kostal (LENKWINKELSENSOR)

Rev. 7, 13-Oct-98 5 (6) Dimensions in mm 14308

Rev. A7, 13-Oct-98 6 (6) Ozone Depleting Substances Policy Statement It is the policy of Vishay Semiconductor GmbH to 1. Meet all present and future national and international statutory requirements. 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as their impact on the environment. It is particular concern to control or eliminate releases of those substances into the atmosphere which are known as ozone depleting substances (ODSs). The Montreal Protocol (1987) and its London Amendments (1990) intend to severely restrict the use of ODSs and forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban on these substances. Vishay Semiconductor GmbH has been able to use its policy of continuous improvements to eliminate the use of ODSs listed in the following documents. 1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively 2. Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental Protection Agency (EPA) in the USA 3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C (transitional substances) respectively. Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting substances and do not contain such substances. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each customer application by the customer. Should the buyer use Vishay-Telefunken products for any unintended or unauthorized application, the buyer shall indemnify Vishay-Telefunken against all claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use. Vishay Semiconductor GmbH, P.O.B. 3535, D-74025 Heilbronn, Germany Telephone: 49 (0)7131 67 2831, Fax number: 49 (0)7131 67 2423