MX24B CHAUVINARNOUX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 126
Technical content
Datasheet sections
For professionals like you: contractors, technicians and engineers in the electrical sector A response based on instruments designed, developed, manufactured and checked by professionals in the electrical sector Measuring instruments n For electrical installation testing n For maintenance of industrial electrical and electronic systems n For metrology: precision measurements n For design work: research and development From design through to industrialization n Measurement of electrical quantities in total safety Rugged, reliable, portable instruments which are high-quality, safe and easy to use n Sales agencies and staff at your service n Technical centres: calibration and repairs n A multi-product website and mini-sites dedicated to specific product ranges Expertise n Technical support, training, mock-ups, etc. Multimeters, clamps, testers and laboratory instruments
Metrix: from the lampmeter, the electro-clamp and oscilloscopes to “the Metrix” In 1936, Georges Friédrichs founded a small company named CARTEX. This company enjoyed considerable growth during the years of economic expansion following the Second World War. Its main business was manufacturing portable “lampmeters” for checking the valves used in the radioelectricity sector, which was growing fast at the time. With the rising demand for electrical and electronic measurement equipment, CARTEX quickly became a major player in this sector, with products such as the lampmeter, testers and frequency generators. In 1946, it changed its name to “Compagnie Générale de Métrologie” (General Metrology Company) and began marketing its products under the Metrix brand. The launch of the “electro-clamp”, allowing users to check voltages without disconnecting and measure high currents with one hand, and the production of oscilloscopes from 1948 onwards helped to quickly expand the company’s offering. However, the products that really made the brand’s reputation were the MX 460, launched in 1950, and more particularly, the MX 462 multimeter, which was so successful that “Metrix®” became the generic name for multimeters in France, enabling the company to grow very fast. As a French brand known nationwide by generations of electricians and electronic engineers, to the point of becoming the generic name for multimeters in France, Metrix® is Chauvin Arnoux’s flagship brand in electronics for multimeters, oscilloscopes, power supplies and generators. The Engineering Department and R&D teams are still based on the site at Annecy-le-Vieux, but they can now take full advantage of the high-performance industrialization tools on the Group’s production sites in Normandy. Technological Breakthroughs and Patented Discoveries …and the MX 400 electro-clamp ASYC IV 100-kcount colour graphical multimeter 1950: launch of the MX 460…
Based in Annecy, the company continued to expand, boosting the local economy, but Metrix’s success and expertise in the measurement field quickly drew the attention of large industrial companies and, in 1964, ITT International (International Telegraph and Telephone) took over the company and incorporated it into its instrumentation division to develop analogue and digital multimeters. With the development of the instrumentation market, the spread of information technology offering new possibilities, the increasingly international competition and the changes in the technological and standardization requirements, Metrix joined the Chauvin Arnoux Group in 1997. This was followed by several years of good- natured competition between Chauvin Arnoux’s teams and the Metrix R&D Department. This gave rise to product ranges such as the MTX Concept multimeters, Scopix oscilloscopes and the MTX Mobile generation of products, as well as the ASYC IV Series more recently. Today, Chauvin Arnoux and Metrix® have merged to offer a complete range of portable and laboratory instruments for electricians and electronic engineers, covering all our customers’ needs. Digital multimeters, oscilloscopes and function generators are designed under the Metrix® brand renowned for its innovations in terms of design, ergonomics and technology. As the inventor of the key switch (MTX mobile®), the smallest oscilloscope with isolated channels on the market (Handscope®) "flip" multimeter (MTX mobile®), the brand’s instruments regularly win awards for their innovative features. Healthy Rivalry The MX 135 analogue multimeter Scopix OX 7104 ASYC IV MTX 3292 colour graphical 100-kcount multimeter MX 24B OX 5042
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr Integrated service! Alongside this extensive, comprehensive offering, 12 agencies under the Manumesure brand provide high-quality, nationwide metrology and regulatory testing services (repairs, metrological verification, pollution measurement, etc.). This expertise is also provided internationally via the ten local subsidiaries. EcoDesign For several years now, the Group has been implementing an ecologically-responsible approach intended to reconcile protection of the environment and the economic imperatives. The Chauvin Arnoux Group’s EcoConception (ecodesign) label highlights the company’s commitment to recycling and recovery of products from the design phase onwards. International presence 10 subsidiaries in Europe, the USA, China and the Middle East, backed by export sales teams, support the Chauvin Arnoux Group’s international development and promote its Chauvin Arnoux, Metrix, Multimetrix, Enerdis, Pyrocontrole, AEMC and AMRA brands on all five continents. Design and production in-house Every year, the Group invests nearly 10 % of its sales revenues in Research and Development to maintain its technological leadership and its reputation for design and constant innovation. Designed in its R&D centres in France, Austria and the USA, the Group’s measuring instruments are manufactured in Chauvin Arnoux’s factories. The plastic and metal mechanical parts are made in Vire while the printed circuits are etched in Villedieu. Assembly, conditioning, storage and shipment worldwide are all handled on the Reux (Pont-l’Évêque) site in Normandy. Chauvin Arnoux is an industrial group with a comprehensive offering covering the whole measurement sector Three French companies, Chauvin Arnoux, Pyrocontrole and Enerdis, offer expertise in portable instrumentation, thermal processes and electrical equipment, and energy efficiency solutions, respectively. 90 % of the products are designed and manufactured entirely in one of Group’s six Research and Development centres. Chauvin Arnoux benefits from production sites mainly based in Normandy, France. Every year, it proposes a palette of more than 5,000 product references to meet the needs of contractors, government authorities and major customers in industry. All the Chauvin Arnoux Group’s sites are certified ISO 9001 and ISO 14001. Visit our website: www.chauvin-arnoux.com
From middle schools... to higher education When studying Science and Technology, measurement is essential for assessing and understanding the theoretical phenomena through practical experiments. In both initial and higher education, it is important to determine the characteristics of a component or system, its behaviour in its environment and its evolution over time, using our measuring instruments. Our offering covers everything from easy-to-use instruments for initial training through to the more complex tools encountered by students when they start their working life. h See examples in the magazine “Les Cahiers de l’Instrumenta- tion” (in French) which deals with measurement in all its forms: news, practical exercises for high schools, reports, etc. Initial training & Electronics In middle schools, one of the first tasks for students involves measuring the electrical quantities and then viewing the waveform of a signal. Multimeters or oscilloscopes with a multimeter function are ideal for this initial familiarization and identification of the fundamental characteristics: amplitude, frequency, etc. h View the case studies available on our website: http:/ /www.chauvin-arnoux.com/ en/notes-dapplication Electrical Engineering classes In these classes, the subjects examined include converters, motors, generators and transformers. This training includes a large number of measurement operations characterized by the presence of significantly higher voltages and currents. Understanding and mastering electrical safety are crucial themes. From Voltage Absence testing with a voltage detector through to the multimeters and clamp multimeters used for TRMS measurements (AC/ DC/ AC+DC), the measuring instruments used for recurrent measurements are equipped with functions ranging from the simplest (resistance, continuity, capacitance, etc.) to the most complex (differential and relative measurements, etc.). h Professional training As a certified training organization since 1993, (certification no. 11.92.06217.92), CHAUVIN ARNOUX proposes specific training courses. http:/ / www.group.chauvin-arnoux.com/ en/formations Education Electricity, electronics, physics, industrial maintenance & the environment: disciplines which constantly involve measurement… For further details…
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr Standards EN 60529 The EN 60529 standard defines an instrument’s level of tightness (leakproofing) to protect it from penetration by so - lids or water. The IP rating corresponds to the instrument’s de- gree of protection against penetration by solids(1st digit) and against penetration by water (2nd digit). The higher the rating, the greater the protection. A product without protection has a rating of IP00 (minimum rating), while a product totally pro tected against penetration by solids and liquids is rated IP68 (maximum rating). IEC 61010 This international standard defines the safety rules for electri - cal measuring, control and laboratory instruments. It helps to guarantee that the design and construction of the instruments ensure protection of users and their environment against: electric shocks, burns, mechanical hazards, fire propagation from these instruments, excessive temperatures, etc. For some types of instruments, this standard is completed with specific instructions. The evolution of industrial and domestic equipment is increa sing the hazards which may be encountered on electrical ins - tallations, with ever-higher overvoltages in particular. On LV installations, where the voltages are limited to 1,000 V ac and 1,500 Vdc, the levels of risk are classified according to the type of installation and voltage level. CAT II Measurements performed on circuits connected directly to the low-voltage installation. Examples: domestic distribution systems, portable and domes- tic instruments and equipment, mains power sockets. CAT III Measurements performed in the installation for a buil - ding. Examples: fixed installations involved in industrial distribution and the entry circuits for electrical maintenance in buildings (lighting, lift/elevator, etc.). CAT IV Measurements performed on the source of a low-vol tage installation. Examples: direct distribution, primary sources, overhead-line and cable systems, including distribution busbars and the re lated equipment for protection against voltage surges. The IEC 61010 family of international standards indicates the safety rules for electrical measuring, control and laboratory ins- truments and their uses. More specifically, it is the IEC 61010- 031 standard and its amendment A1 which define the safety rules for measuring instruments and their accessories. In the new edition applicable from 1st March 2011, this standard was completed with the addition of Chapter 13 which deals with “prevention of hazards linked to short-circuits and electric arcs”: This modification imposes rules for work on CAT III and CAT IV installations:
- For the test probes, the conducting part of the accessory must not be longer than 4 mm
- For crocodile clips, the external surfaces of the jaws must be No-conducting and the conducting parts must not be acces sible when the clip is closed. The IEC 61010-2-033 standard, whose first edition was publi - shed on 9/02/2013, brought changes concerning multimeters, clamp multimeters, etc. Since 9th March 2015, these instruments must ensure a level of safety corresponding at least to 300 V CAT III. IEC 61557 This international standard specifies the electrical safety features in 1,000 V ac and 1,500 V dc low-voltage distribution networks. It defines all the requirements for the combined measurement and supervision systems which measure and monitor the electrical parameters on electrical distribution networks. These requirements also define the performance le vels on single and three-phase AC or DC networks with rated voltages less than or equal to 1,500 V dc. The main parts of the IEC 61557 standard applicable to mea - surement and testing in our sector are: Part 1: IEC 61557-1: General information Part 2: IEC 61557-2: Insulation resistance Part 3: IEC 61557-3: Loop impedance Part 4: IEC 61557-4: Resistance of earth and equipoten tial bonding Part 5: IEC 61557-5: Resistance to earth Part 6: IEC 61557-6: Effectiveness of the residual cur - rent devices (RCDs) in TT, TN and IT networks Part 7: IEC 61557-7: Phase sequence NF C 15-100 This is the official French safety standard governing the pro - tection of low-voltage electrical installations and the people close to them, as well as easy management, use and upgra deability of the installation. Residential installations (house or apartment) must comply with this standard. In particular, NF C 15-100 defines the protective devices, RCDs, wiring, number and type of lighting point, as well as the nu mber of power sockets according to the type of room (ba - throom, kitchen, etc.).
All our products comply with the safety standards and new products were added to the Metrix ® range in 2015: And more are on the way… The B ASYC multimeters to complement the ASYC IV models: a revitalized range for your basic measurement needs Expertise required... 4-CHANNEL benchtop oscilloscopes For the electronics sector… For electrical engineering and power electronics... Basic measurements… B ASYC ASYC IV range DOX range OXi6204
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr MULTIMETERS THEORY Technical reminders Number of measurement counts This is one of the fundamental specifications of instruments using analogue-digital conversion. In general, it can be used to define the measurement range and the resolution, on the basis of the value chosen for the rated calibre. Measurement range This indicates the limits within which the digital instrument maintains all its specifications, so the indications obtained are not subject to an error greater than the maximum tolerated error. It is defined by a minimum value and a maximum value. Rated calibre The calibre of an instrument is the value of the quantity to be measured which corresponds to the upper limit of the measurement range. For example, for an ammeter, if this upper limit is 5 A, its calibre is said to be 5 A. Resolution This is the smallest measurable value. It is also the value of a measurement count or quantification unit, usually termed "the unit". Minimum measurable value (or threshold) This is the smallest measurable value. For an instrument with good linear conversion, it may be equal to the resolution. This is not always the case and the manufacturer should clearly indicate it, as this minimum value also depends on the accuracy and, more particularly, the standard error. When the standard error is too high, it becomes impossible to measure very low values reliably. RMS: Root Mean Square By definition, the RMS value of any current is the DC current value which would cause the same heating when flowing through a resistor. In the specific case of a sinusoidal quantity, application of the above equation yields: The amplitude (Vpeak) of a voltage or sinusoidal current is equal to √2 times its RMS value (Vpeak = √2 Vrms). Knowledge of this RMS value is essential in the industrial sector as it is this value which is used to define a current. So, for the 230 V/50 Hz network: V rms = 230 V ; Vpeak = 325 V ; Vavg = 207 V An "average value" measuring instrument measures the average value of a sinusoidal current, after rectification and filtering and displays the RMS value after application of a coefficient equal to 1/0.9 = 1.111. For a sinusoidal alternating voltage Vpeak = Vrms x √2 Vaverage = 0.9 Vrms
This indirect measurement method is simple and accurate, but it is only valid for sinusoidal currents without distortion. It only tolerates distortion amounting to a few per cent. This is why "RMS" measuring instruments are seeing increasing use. They are based on direct measurement principles: thermal measurement (used mainly in metrology) and analogue or digital calculation methods requiring sophisticated electronic components. Peak value – Crest Factor The crest factor is defined as follows: CF = Vpeak / Vrms This additional information complementing the RMS value can be used to assess the distortion of a signal in qualitative terms. For a sinusoidal signal, CF = √2 = 1.414. Advice: When we speak of a 230 V network voltage, it is an RMS value. For many years, the linear loads (incandescent lamps, heating) connected to the network caused very little distortion. The spread of No-linear loads (switching power supplies, light dimmers, variable speed drives and compact fluorescent lamps) is calling this approach into question because the network's "pure" sinusoid is becoming increasingly rare. Conventional measuring instruments (which give the "effective" value on the basis of the average value) are only accurate, by definition, with sinusoidal currents. Otherwise the measurement error may be as high as 50 %! You are advised to choose RMS measuring instruments capable of providing correct measurements whatever the waveform of the current or voltage. Safety rules and good practice: - Use measuring instruments and accessories suitable for the application and measuring conditions. Prefer CAT IV instruments:
- It ensures a voltage withstand up to 50% higher than a CAT III product
- 1,000 V CAT IV means protection against electric shocks up to 12,000 V, while 600 V CAT IV instruments protect up to 8,000 V.
- If you use a lower-category instrument, you must ensure that the installation is equipped with protective systems (disconnecting switch, circuit breaker, etc.) which are functional and in good condition. This is often the case... but not always!
- For outdoor or temporary installations, or for installations upstream of the protective systems, CAT IV instruments are mandatory. - It is the weakest element which defines your level of protection. If you use accessories with a lower category or voltage rating than your measuring instrument, the overall safety level offered by your measurement system is also reduced. - Use accessories in perfect condition. Any accessories presenting even the slightest defect must be replaced immediately because they no longer guarantee your safety. - Fuses are protective devices. If you replace them with cheaper models or, even worse, with a metal element (copper wire, aluminium foil, etc.), they will not protect you from possible voltage surges on the installation. multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr TESTERS Selection guide Choose your tester or analogue multimeter Types SMD tester Voltage tester Analogue multimeters Field testers Quick selection TCX 01 TX 01 MX 1 MX 2B VX 0003 VX 0100 Specifications Voltage measurement AC AC and DC AC and DC Resistance measurement X X X X Capacitance measurement X Diode test X X X Continuity test X X X X Phase identification X Current measurement AC and DC AC and DC Current measurement with clamp MN09 200A X X LF electric field measurement (V/m) 10Hz-3 KHz 10Hz -100KHz LED - analogue display X X X X Digital display X X Power supply: battery / type 2x1.5v /LR44 1x9V/6F22 1x 1.5V/LR6 1x9V/6F22 Pages 9 12 13 13 10-11
n Automatic recognition of the SMD n Wide dynamic range for measurement (6,000 counts for accurate testing of the highest and lowest values) n Immediate implementation n Test probes protected by a rigid cap Ergonomic, simple and quick for instant SMD identification. Surface Mount Device (SMD) tester Standard state at delivery: TCX001-Z: 1 TCX delivered with soft case for storage, 2 x 1.5 V button cells and operating manual Specifications TCX 01 Display 6,000 counts Selection of ranges Automatic or Manual Range Resolution Accuracy 600 Ω 0.1 Ω 6 kΩ 1 Ω Resistance 60 kΩ 10 Ω ±(1.2 % of reading + 2 digits) 600 kΩ 100 Ω
6 MΩ 1 kΩ
60 MΩ 10 kΩ ±(2 % of reading + 2 digits)
6 nF 1 pF ±(5.0 % of reading + 5 digits 60 nF 10 pF 600 nF 100 pF ±(3.0 % of reading + 3 digits) Capacitance 6 µF 1 nF 60 µF 10 nF 600 µF 100 nF ±(5.0 % of reading + 5 digits) 6 mF 1 µF 60 mF 10 µF - Diode and semiconductor junction test 2 V Itest: ~1 mA / Vtest: ~2.8 V Continuity test R < 30 Ω Automatic shutdown 10 min Power supply 2 x 1.5 V AG13 / LR44 / 357A Dimensions / weight 181 x 35 x 20 mm / 65 g multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr LF ELECTRIC FIELD TESTERS VX 0003 & VX 0100 n Test of the pollution generated by electrical power distribution (0-3 kHz) (VX 0003/VX 0100) n Test of the pollution generated by the equipment connected (3-100 kHz) (VX 0100) n 2 complementary methods for more effective measurements - Representative method: field measurement while taking the individual's presence into account - Traditional method: fields referenced to earth n External antenna for field measurement and cable detection (VX 0100) n Audible alarm for immediate identification of the field levels n Testing in accordance with the current and future standards and directives Measure your exposure to electromagnetic pollution in your home or office. The VX 0003 and VX 0100 testers are easy-to-use, economical and trustwor- thy! They are used mainly when testing new or renovated electrical installa- tions and in technical and vocational training. Standards
- WHO / ICNIRP recommendations (World Health Organization / International Commission on No-Ionizing Radiation Protection)
- IEEE C95.6-2002 (international standard - Public, 0-3 kHz range)
- European Directive 1999/519/CE (Public, 0-100 kHz range and beyond)
- European Directive 2004/40/CE (Workers, 0-100 kHz range and beyond)
- 2010 draft standard, EN IEC 62493 (lighting systems)
- EN50366 standard and IEC 62233 in 2012 (domestic electrical equipment) Example of application Low-frequency fields between 10 Hz and 100 kHz are harmful. The VX 0003 and VX 0100 BioTest field testers/meters instantaneously indicate the level of the low-frequency electric field. Ideal for the residential and tertiary sectors, they can be used by both professionals and DIY enthusiasts. HzV
For further details… Standard state at delivery
1 VX delivered with earth cable,
socket tester and 9 V battery Specific optional accessories
1 VX delivered with earth cable, socket tester and 9 V battery
VX0003: VX0003 field tester delivered with a bag VX0100: VX0100 field tester delivered in a case For the VX 0100:
- HX0104 bag For the VX 0003:
- HX0009 case LF ELECTRIC FIELD TESTERS Technical specifications VX 0003 VX 0100 Display & Buzzer Display on 2 scales of 7 LEDs each • 2,000-count backlit LCD display • Direct display in Volt/m (compatible with standards) • • Buzzer proportional to the field level • • Indication of the measurement frequency range • "Low battery" & "Hold" indicators • • Commands On / Off (with automatic shutdown after 30 min) • • Measurement Hold • • Buzzer On/Off • • Selection of measurement range Manual Automatic Selection of 3 kHz filter (<, >, full band) • Antenna & Reference Built-in "field" antenna • Removable "field" antenna, diameter 62 mm + Cable detection function "Individual" field measurement reference + continuity rod
- • Optional accessory "Earth" field measurement reference • • Measurements RMS electric field intensity in V/m • • Sensitivity & Accuracy 2 sensitivity ranges (compatible with standards) 5 to 100 V/m - 100 to 2,000 V/m 1.0 to 200.0 V/m - 200 to 2,000 V/m Measurement accuracy (in laboratory conditions) ± 10% on LED thresholds ± 3% ± 20 D @ 50/60 Hz Frequency range Analysis of electrical distribution, 10 Hz to 3 KHz • • Analysis of equipment connected to the mains 10 Hz to 3 kHz
10 Hz to 3 kHz (3 kHz low-pass filter)
3 kHz to 100 kHz (3 kHz high-pass filter)
10 Hz to 100 kHz (no 3 kHz filter)
Power supply 9 V battery (supplied) – Battery life 60 to 80 hours Automatic shutdown function (30 min) Mechanical specifications IP65 leakproof casing- Dimensions 63.6 x 163 x 40 mm – Weight approx. 200 g with battery Warranty 2 years Bag for VX testers Continuity rod multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr vOLTagE TESTER TX 01 n AC and DC voltage testing n Electrical continuity testing with audible and visual indication n Phase identification n Autotest function to check the status of the instrument and the battery n Extra-bright LEDs n Removable test probe with standard Ø4 mm banana connection n Built-in system for stowing the lead An essential tool for electrical testing and diagnostics. LED voltage tester Standard state at delivery TX0001-Z: delivered with a removable test probe, a 9 V battery and an operating manual V Specifications TX 01 Voltage test 12 V to 690 V (7 diodes) Audible alarm U > 50 V Phase identification Flashing "Ph" diode for U > 100 V~ Operating frequency DC … 400 Hz Audible continuity Yes Resistance 2 kΩ to 300 kΩ (3 diodes) Power supply 1 x 9 V 6F22 Electrical safety 600 V CAT III Dimensions / Weight 193 x 47 x 36 mm / 170 g Other features Built-in 1.2 m lead with Ø2 mm test probe + Ø2 mm removable test probe
Standard state at delivery MX 1 with 1 set of measurement leads with test probes, 1 x 1.5 V battery and user manual in 5 languages MX 2 with 1 set of measurement leads with test probes, 1 x 1.5 V battery, 1 current clamp and user manual in 5 languages References to order MX1: 1 MX 1 MX0001-T: 1 MX 1 delivered with 1 TX1 voltage tester and a hard case. MX0002B: 1 MX 2B delivered with an MN09 current clamp MX0002BT: 1 MX 2B delivered with an MN01 current clamp, 1 TX1 tester and a hard case P01105101Z: 1 MINI01 current clamp P01120402: 1 MN09 current clamp TX0001-Z: 1 TX01 LED testerAvailable accessories See pages 97 to 106 Mini 01 (1) Use limited to 600 Vmax MX 2B with MN 09 For further details… MX 1 & MX 2B n IP65 shockproof and leakproof casing n Audible continuity n Protection of the ohmmeter function by an audible alarm n Parallax mirror for precise measurements n Faulty fuse indicator n Measurement up to 200 A with clamp (MX 2B) With their needle and dial, the MX 1 and MX 2B multimeters are easy to read and quickly display the measurement results. ON-SITE aNaLOgUE MULTIMETERS V A dB Specifications MX 1 MX 2B Display Analogue with parallax mirror / Scale length 80 mm DC voltage 10 mV to 600 V 0.01 V to 600 V Calibres 150 mV / 0.5 V / 1.5 V / 5 V / 15 V / 50 V 0.5 V / 1.5 V / 5 V / 15 V / 50 V 150 V / 500 V / 1.5 kV(1) 150 V / 500 V / 1.5 kV(1) Accuracy class 2 2 AC voltage 10 mV to 600 V 0.01 V to 600 V Calibres 5 V / 15 V / 50 V / 150 V / 500 V / 1.5 kV(1) 5 V / 15 V / 50 V / 150 V / 500 V / 1.5 kV(1) Accuracy class 2.5 2.5 DC current 2 µA to 10 A 1 µA to 50 µA / 10 A Calibres 50 µA / 500 µA / 5 mA / 150 mA / 500 mA / 1.5 A / 10 A 50 µA / 10 A Accuracy class 2 2 AC current 20 µA to 10 A With a 1,000/1 clamp Calibres 50 µA / 500 µA / 5 mA / 150 mA / 500 mA / 1.5 A / 10 A 10 A / 20 A / 100 A / 200 A Accuracy class 2.5 3 Resistance Audible alarm for voltage presence Calibres x 1 / x 10 / x 100 Middle point 200 Ω / 2 kΩ / 20 kΩ Accuracy class 2.5 Audible continuity < 150 Ω Other measurements Diode test Yes dB Yes Protection rating IP 65 Power supply 1 x 1.5 V AA or LR6 Electrical safety 600 V CAT III as per IEC / EN 61010-1 Edition 2 Dimensions / Weight 40 x 98 x 150 mm / 420 g Specifications MINI 01 MN 09 Clamping diameter 10 mm 20 mm Measurement range 2 A to 150 Aac 0.5 A to 200 Aac Transformation ratio 1,000/1 1,000/1 multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr ON-SITE MULTIMETERS Selection guide High-End Graphical Multimeter/Recorder Industry, Electrical Engineering, Electronics Quick selection MTX 3292 MTX 3293 Technology Graphical colour Display resolution (counts) 100,000 TRMS / AVG measurement TRMS AC & AC+DC Simultaneous display(s) 4 Fast bargraph • Graph of measurements over time • Backlighting / Automatic power-off •/• DC basic accuracy 0.02 % to 0.1 % Bandwidth 100 kHz or 200 kHz Auto / Manual ranges •/• AutoPeak for Crest Factor • Ingress protection IP67 Explosive atmospheres (ATEX) Available measurements AC/ DC voltage 1,000 V AC/ DC current 20 A (30 s) Single A terminal / Simultaneous U & I •/• Resistance / audible continuity / diode test 10 MΩ /•/• Frequency / period / duty cycle 5 MHz /•/• Pulse width / pulse count •/• Capacitance 10 mF Temperature Pt100-Pt1,000 / TC J-K •/• dBm / resistive power •/• U & I peak / crest factor 250 µs /• Filter for digital variable speed drives 300 Hz Direct measurement with clamp All, ratio integrated Low impedance AC voltage measurement 500 kΩ Measurement processing Display Hold / Auto-Hold functions •/• Min / Max / Avg monitoring •/•/• Relative measurements / dB ratio / % •/•/• Memory capacity + measurement graphs 6,500 Time/date-stamping (SURV & MEM) • RS232 / USB / Bluetooth interface •/•/• Safety & reliability EN61010 CAT IV / III 600 / 1,000 Electronic switch • Protected access to batteries / Fuses •/• "Closed casing" software calibration • Catalogue page 26-27 Multimeter families to meet all your needs: an authentic for everyone (1) Depending on models. (2) MTX 3291 model only
Digital for Difficult Environments General-purpose Digital Benchtop Digital Industry Atex / IECEx Electrical Laboratory MTX 3290 MTX 3291 MTX 57EX MX 24 MX 24B MTX 202 MTX 203 MX 5006 MX 5060 Digital Digital Digital Digital Digital 6,000 or 60,000 50,000 5,000 / 50,000 (1) 2,000 or 4,000 6,000 or 60,000 TRMS AC & AC+DC TRMS AC & AC+DC TRMS AC & AC+DC TRMS AC TRMS AC & AC+DC 2 1 1 1 2
- • • • 20 kHz or 100 kHz 50 kHz 1 kHz 1 kHz 20 kHz or 100 kHz
- • IP67 IP67 IP54 1,000 V or 600 V 600 V 750 V / 1,000 V 750 V / 1,000 V 1,000 V or 600 V
20 A (30 s) (1) 500 mA 20 A (30 s) (1) 10 A (1) 20 A (30s)
60 mF 50 mF 50 mF 100 mF 60 mF
- /- •/- -/• •/- 250 µs /• 1 ms/- 250 µs /•
300 Hz 1 kHz BW 300 Hz
V/A ratio • 300 kΩ • 500 kΩ 300 kΩ - - Relative Surv Relative Surv 600 / 1, 000 (2) - / 600 - / 600 - / 600 600 / 1,000
- • •/• 24-25 21 18-19 16-17 30-31 Multimeter families to meet all your needs: an authentic for everyone multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr BaSIC ON-SITE DIgITaL MULTIMETERS n Automatic TRMS AC measurements on all the calibres for most of the customary electrical signals: - AC/DC voltage; - VLowZ low-impedance voltage; - temperature in °C and °F via K thermocouple; - resistance and audible continuity, diode threshold voltage test; - capacitance measurement and AC/DC current measurement from 1 µA to 10 A (depending on model) plus manual RANGE n No-contact voltage (NCV) indication useful for detecting live cables at 230 V n A compact casing with a multi- purpose sheath which fits in one hand: stowing of the leads, magnetized for mounting on metal cabinets and shockproof protection with the MULTIFIX system n Blue backlighting with torch for optimized display in dark environments n Automatic power-off after 30 minutes without activity which can be inhibited (permanent mode) to optimize the 500-hour battery life and the lifespan of the batteries n Easy access to the 2 x 1.5 V batteries and fuse(s) by loosening 2 screws on the rear n Compliant with the latest IEC61010-2-033 – 600 V CAT III safety standards A range of 2 simple, basic TRMS AC multimeters with digital display for measuring on electrical networks and installations up to 600 V CAT III. These multimeters are general-purpose professional measuring instruments. They are the best tools for day-to-day use requiring the TRMS measure- ments, accuracy, rugged design and reliability of an on-site instrument. MTX 202 & MTX 203 Concept TRMS AC The Metrix® tools of reference for applications in the electrical sector V A
Standard state at delivery 1 multimeter with batteries and fuses installed, 1 elastomer sheath with stand, 1 set of 2 safety leads, 1 wire K thermocouple, user manual References to order MTX202-Z: MTX202 delivered in blister pack MTX203-Z: MTX203 delivered in blister pack Available accessories See pages 97 to 106 For further details… BAsIC On-sITE DIGITAL MULTIMETERS Specific or adapted accessories Specifications MTX 202 MTX 203 Quick selection Display resolution 4,000 counts 6,000 counts Automatic power-off 30 min / Permanent mode Basic accuracy (Vdc) 0.2 % Bandwidth 1 KHz Available measurements AC/DC voltage (ranges) 400 mV to 600 V / 600 V 600 mV to 750 V / 1,000 V AC/DC current (ranges) 20 mA to 10 A 10 µA to 10 A Resistance (ranges) 1 Ω to 40 MΩ 1 Ω to 60 MΩ Audible continuity Yes Diode test Yes Capacitance (ranges) 1 nF to 100 mF NCV 230 V / 50 Hz Temperature -55 °C to 1,200 °C Measurement processing Other measurements HOLD mode General specifications Power supply / Battery life 2 x 1.5 V batteries / 500 h Dimensions / Weight 170 x 80 x 50 mm / 320 g Safety and reliability High-resistance casing IP 54 Warranty 2 years BaSIC ON-SITE DIgITaL MULTIMETERS Bag: HX0052B K Thermocouple: P01102107Z SHT 40kV probe: P01102097 multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr ON-SITE DIgITaL MULTIMETERS n Bandwidth up to 100 kHz n A VLowZ low-impedance function to avoid stray voltages n Innovative design with a compact, rugged casing n Large display with bargraph and backlighting for easy reading n Elastomer protective sheath n Unique system for easy access to the batteries and fuses with extra safety n MIN/MAX/AVG function to monitor the changes in the signal n MEM/Auto mem function to allow you to freeze the display TRMS measurements for accurate results whatever the waveform. MX 24 & MX 24B TRMS AC & TRMS AC+DC Concept Recyclable and recoverable, in compliance with the DEEE- 2002/96/CE directive HzV A
MX0024-CG: MX 24 MX0024-CL: MX 24 delivered in hard case MX0024B-CZ: MX 24B in blister pack MX0024B-CL: MX 24B delivered in hard case Available accessories See pages 97 to 106 For further details… On-sITE DIGITAL MULTIMETERS Standard state at delivery
1 MX: 1 elastomer sheath, 1 set of 2 safety leads,
Specifications MX 24 MX 24B Quick selection Display 5,000/50,000 counts + bargraph Backlighting/auto-shutdown Yes / Yes TRMS measurements TRMS AC+DC Basic accuracy for DC voltage 0.3 % Bandwidth 1 kHz Available measurements AC/DC voltage (ranges) 500 mV to 750 Vac / 1,000 Vdc AC/DC current (ranges) 50 mA - 20 A 500 mA - 20 A Resistance/audible continuity 500 Ω to 50 MΩ / Yes Frequency 5 Hz to 500kHz Capacitance / diode test 50 nF to 50mF / Yes Measurement processing Min/Max/Avg monitoring Yes / Yes / No PC communication / backup No Safety and reliability Warranty 3 years ON-SITE DIgITaL MULTIMETERS multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr MULTIMETERS FOR DIFFICULT ENvIRONMENTS Use in explosive gas and dust atmospheres in the following conditions: n Mines: category I M2 n Surface indus tries: category 2 (gas and dust) I I 2GD - Zones 1 & 2 (gas ) Ex ib I and Ex ib IIC T5 or T4 or T3 - and zones 21 & 22 (dust) Ex ibD21 IP6X T°… °C The MX 57Ex is a comprehensive instrument which complies with the applicable standards and regulations. It also complies with the stipulations of the European directives: n Low V oltage 2006/95/CE n Electromagnetic Compa tibility EMC 89/336/CE and 93/68/CE ATEX 2014/34/UE directive EN/IEC 60079-0 – EN/IEC 60079-11 EN/IEC 61241-11 – EN/IEC 61241-0 EN/IEC 61010-1 – 600 V CAT III It is certified LCIE 02 ATEX 6005 X and, according to the "old regulations", EEx ib IIC T5 / EEx ib I according to: n CE inspection certificate of type number LCIE 02 ATEX 6005 X and amendments LCIE 02 ATEX 6005X / 01, 02, 03, 04 It is equipped with a 500 mA fuse. It is supplied in a bag with some of its accessories. This ATEX-certified 50,000-count TRMS digital multimeter is designed for use in hazardous environments. MX 57EX ASYC II multimeter A unique tool for all your measurements usable in explosive and non-explosive environments HzV A The temperature class depends on the battery used :
Standard state at delivery 1 multimeter with battery and fuse(s) installed, 1 elastomer sheath with stand, 1 set of 2 PVC safety leads and 1 user manual Reference to order MX0057CX: MX 57 delivered in a specific soft case Available accessories See pages 97 to 106 For further details… MULTIMETERS FOR DIFFICULT EnVIROnMEnTs Specifications MX 57EX Display 50, 000 counts Bargraph Analogue, 34 segments, 20 meas./s DC, AC & AC+DC voltage Ranges 5 calibr es from 500 mV to 600 V Vdc accuracy 0.02 5 % Vac accuracy 0.3 % Bandwidth 50 kHz DC, A C & AC+DC current Ranges 500 μA, 5 mA, 50 mA & 500 mA Adc accuracy 0.2 % Aac accuracy 0.6 % Bandwidth 5 kHz Fr equency Ranges 0.62 Hz to 500 kHz - Accuracy 0.03% Other measurements Resistance 6 r anges from 500 Ω to 50 MΩ Audible continuity Detection thr eshold from 10 Ω to 20 Ω - response time 1 ms Diode test 0 to 2 V Capacitance 7 r anges from 50 nF to 50 mF Temperature -200 °C to +800 °C Pt100 or P t1,000 platinum probes Duty cy cle – dB function Other features and U2/R resistive power Pulse width – timer – e vent counting General specifications Battery life 1 c ertified 9 V battery / 300 hrs Dimensions / Weight 189 x 82 x 40 mm / 400 g (without sheath/stand) Safety and reliability Safety ATEX 94/9/CE directive EN/IEC 60079-0 – EN/IEC 60079-11 EN/IEC 61241-11 – EN/IEC 61241-0 EN/IEC 61010-1 – 600 V CAT III + EN 61010-2-030 2010 CE inspection certificate type number LCIE 02 ATEX 6005 X and amendments LCIE 02 ATEX 6005X / 01, 02, 03, 04 High-resistance casing IP 6 7 Warranty 3 years MULTIMETERS FOR DIFFICULT ENvIRONMENTS multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr aSYC Iv FaMILY OF DIgITaL MULTIMETERS n IP67 leakproof multimeters n Graphical display of the trends and multiple parameters n Bandwidth: 200 kHz n Basic accuracy: 0.02 % n Multiple analytical tools: - Time/date-stamped monitoring of MIN/MAX/AVG and PEAK - Direct current measurement with integration of the report n Directly accessible, the various measurements are represented explicitly by pictograms on the electronic switch n The display allows users either to view the measurement results as numerical values, on 2 display levels, or as graphs showing the trend over time Multimeters with colour graphical screens for the lab or the field: the reference for multimeters. is revolutionizing multimeters with the ASYC IV ... Plus unrivalled simplicity of use, as always! IP 67MAX/MIN AVG/PEAK Digital keypad which lights up the active function, storage of configurations
AsYC IV FAMILY OF DIGITAL MULTIMETERS is revolutionizing multimeters with the colour graphical ASYC IV models This recorder-multimeter offers: The ASYC IV multimeters are ideal for many applications in industry, telecommunications and Defence. Their multiple functions make them easy to use for electrical, electronic or machine maintenance. In electronics, the ASYC IV models can be used to test cabling, computing or medical equipment or SMDs. In industry, they are suitable for the applications encountered in departments dealing with the automated systems and processes in highly varied sectors: food, plastics, concrete, metal, paper, wood, oil and nuclear. The ASYC IV models can be used for maintenance of many industrial machines: numerical control, motors, generators, etc. These versatile instruments are ideal for the needs of expert electrical installers and professionals in the transport and energy sectors. High-performance, accessible and ergonomic, the ASYC IV models can also be used in training and research. aSYC Iv FaMILY OF DIgITaL MULTIMETERS n The four ASYC IV models Colour 320 x 240-pixel liquid-crystal matrix screen with black background for easier reading n Graphical display of the trends on an overview screen n Trace, cursors and zoom on recordings n Recording of 10 sequences Dynamic recorders... n Up to 6,500 measurements stored in memory n Simplified definition of the number of measurements, the interval, the duration and the memory capacity n Internal storage of the 10 measurement sequences n Interactive zoom function on the recordings n A simple monitoring mode displaying the time/date-stamped MIN/MAX and AVG values Models LCD MTXs GRAPHICAL MTXs MTX 3290 MTX 3291 MTX 3292 MTX 3293 Type of display Digital Digital monochrome monochrome Colour graphical 70 x 52 mm backlit 70 x 52 mm 70 x 52 mm Type of display 7 function keys + setup Counts 6,000 60,000 Data storage 1,000 meas. 6,500 meas. Power supply 4 x R6 batteries or 4 rechargeable batteries Communication IR / USB IR / USB (Bluetooth option) multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr n An innovative design with ergonomics suited to work in the field: fingertip function selection on the numeric keypad and comfortable grip, a large backlit LCD screen (3 positions) for viewing 2 simultaneous measurements (segments 14 mm high) n Unrivalled user-friendliness: - "Virtual" one key / one function - Automatic V/A selection by cable positions and 8 backlit function keys n Up to 2 x 60,000-count digital displays + bargraph: central zero, V dc and Idc n 3 connection terminals, so a single fuse from 1 μA to 10 A n Reminder of the measurement connections for each function n Extra-versatile: V, A, Ohms, Hz, diode, capacitance, dB, °C, etc. Low-impedance measurement, time/date-stamped MIN, MAX and AVG monitoring, etc. n CLAMP function for direct measurement of the current by integrating the transformation ratio: 1/1, 1/10, 1/100 and 1/1,000 mV/A n Secondary measurements for electronics: DBm, resistive power, counting, pulse width, gain measurement, resistive power n Communication for MTX 3291: isolated USB; "real-time" data transfer onto PC, drivers and SCPI commands The METRIX® designed for the field: a single, comprehensive, high-performance diagnostic instrument which nevertheless remains particularly easy to use! MTX 3290 & MTX 3291 Unique on the market, the electronic switch replaces the traditional mechanical switch, which is the major source of faults on handheld multimeters, while also improving performance and safety. At the same time, the possibility of direct access using the keypad avoids the intermediate positions typical of mechanical switches. Each main measurement is instantaneously accessible with one of the 6 dedicated keys, without having to choose between the 4 or 5 positions of a mechanical switch for a simple voltage or current measurement. aSYC Iv FaMILY OF DIgITaL MULTIMETERS Multimeters with fingertip control HzV A
HX0056-Z: optical/USB cable MTX328X and MTX329X HX0053: external NI-MH battery charger for MTX328X and MTX329X HX0052B: transport kit for MTX329X 6,000 and 60,000 counts Standard state at delivery Multimeter delivered with 4 x 1.5 V alkaline batteries, red straight/ straight lead 1.5 m long, black straight/ straight lead 1.5 m long, red CAT IV 1 kV test probe, black CAT IV 1 kV test probe, user manual on CD and startup guide on paper, USB cable and remote programming manual for communicating version References to order MTX3290: DMM 6 kcts TRMS 20 kHz MTX3291: DMM 60 kcts TRMS 100 kHz USB Available accessories See pages 97 to 106 For further details… AsYC IV FAMILY OF DIGITAL MULTIMETERS Technical specifications MTX 3291* MTX 3290 Length of scale Range 60 mV 600 mV 6 V 60 V 600 V 1,000 V DC accuracy 0.05 % 0.3 % AC and AC+DC bandwidth 100 kHz 20 kHz AC and AC+DC basic accuracy 0.5 % 0.8 % VLowZ AC 300 kΩ DC, AC and AC+DC current Range 600 µA 6 mA 60 mA 600 mA 6 A 10 A / 20 A (30 s max) DC accuracy 0.08 % AC and AC+DC bandwidth 20 kHz 20 kHz AC and AC+DC basic accuracy 1 % 1.5 % Frequency Frequency range 60 Hz 600 Hz 6 kHz 60 kHz 600 kHz Resolution* 0.01 Hz 0.1 Hz 1 Hz 10 Hz 100 Hz Resistance and continuity Ranges 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 60 MΩ Resolution* 0.1 Ω 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ Basic accuracy 0.2 % 0.5 % Protection Electronic protection Audible continuity detection 600 Ω SIGNAL < 30 Ω +/- 5 Ω < 5 V Diode test Voltage measurement 3 V - resolution 1 mV Capacitance Ranges 6 nF 60 nF 600 nF 6 µF 60 µF 600 µF 6 mF 60 mF Temperature Pt100/1,000 Operating range -200 °C to +800 °C Accuracy 0.1 % Other functions MAX / MIN / AVG or PEAK +/- On all the main positions measured ΔREL REL relative value + secondary display with measured reference value PWM filter 300 Hz 4th-order low-pass filter for measurements on variable speed drives of asynchronous motors Clamp function V output with direct reading Integration of ratio: 1/1, 1/10, 1/100, 1/1,000 mV/A Secondary functions dBm and resistive power in VA, +/- duty cycle and pulse width Central zero Selectable or automatic for Vdc and Idc USB communication With SX-DMM - SCPI commands General specifications Type of display Transflective LCD with backlighting* and digits 14 mm high Double 60,000-count or 6,000-count display PC interfaces USB optical socket - SX-DMM software Power supply 4 x AA batteries (or Ni-MH rechargeable batteries) Safety / EMC Safety as per IEC61010-2-033 – 1 000 V CAT III* / 600 V CAT IV – CEM as per EN61326-1 Environment Storage: -20 °C to +70 °C – Operation: -10 °C to +50 °C Mechanical specifications Dimensions (L x W x H): 196 x 90 x 47.1 mm / Weight: 570 g Warranty 3 years aSYC Iv FaMILY OF DIgITaL MULTIMETERS (*) MTX3291 only multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr 2 portable multimeters with colour graphical display for direct measure- ment of the main electrical quantities: innovative design, compact, rugged, leakproof and easy to grip for all your measurements. ASYC IV, the new tools from Metrix n Colour 320 x 240-pixel liquid-crystal matrix screen with black background for easier reading n Multi-parameter display: 1 main and 4 secondary measurements n 4 x 100,000-count display and TRMS AC+DC converter n 1,000 V CAT III protection n Bandwidth: 100 kHz to 200 kHz n Voltage measurement up to 1,000 V n Current measurement up to 10 A (20 A for 30 s) n Resistance measurement up to 50 MΩ n Capacitance measurement up to 10 mF n Frequency measurement up to 5 MHz n K/J thermocouple or Pt temperature measurement from -200 °C to +1,200 °C n Current measurement using clamp with direct reading (integration of ratio) n Numerous additional measurement functions: low-pass PWM filter (variable speed drive), and V LowZ low impedance measurement (500 k), dB/dBm measurement, duty cycle, pulses, diode measurements: Zener or LED, etc. n A "reference" multimeter with its 100 kcounts and display of its specifications associated with a RELative mode High-level multimeters… n Graphical display of the trends on an overview screen n Recall of traces, cursors and zoom on recordings High-performance graphical multimeters… n Up to 6,500 measurements stored in memory n Simplified definition of the number of measurements, the interval (1 s to 24 h), the duration and the memory capacity n Internal storage of 10 measurement sequences n Interactive zoom function on the recordings n In addition, a simple monitoring mode displaying the time/date-stamped Min / Max and Avg values Dynamic loggers for capturing faults... n Contextual reminder of connections n Classic USB communication or Bluetooth available as an option; the SX-DMM software can be used for real-time processing of the data on a PC, instrument upgrades and instrument calibration, with new functions: automatic time adjustment and display of available memory capacity n IP67 ingress protection: waterproof and dustproof, ideal for outdoor conditions n Rechargeable Ni-MH AA battery with low self-discharge, the best solution in terms of quality and price: 4-level indication of battery capacity + % n Battery life of up to 100 hours with management of the level n No time wasted: the instrument operates while it is charging n Developed and manufactured in France …And much more! aSYC Iv gRaPHICaL FaMILY DIgITaL MULTIMETERS HzV A
Standard state at delivery Multimeter delivered in screen-printed box with 4 x NI-MH 2400 mAH 1.5 V rechargeable batteries, red straight/ straight lead 1.5 m long, black straight/ straight lead 1.5 m long, red CAT IV 1 kV test probe, black CAT IV 1 kV test probe, USB optical cable + SX-DMM software, user manual on CD and startup guide on paper References to order MTX3292: DMM graph TRMS 100 Kcts Colour 100 kHz USB MTX3292-BT: DMM graph TRMS 100 Kcts Colour 100 kHz BLUETOOTH MTX3293: DMM graph TRMS 100 Kcts Colour 200 kHz USB MTX3293-BT: DMM graph TRMS 100 Kcts Colour 200 kHz BLUETOOTH Available accessories See pages 97 to 106 For further details… AsYC IV GRAPHICAL FAMILY DIGITAL MULTIMETERS Technical specifications MTX 3292 MTX 3293 Length of scale Range 100 mV* 1,000 mV 10 V 100 V 1,000 V Resolution 1 µV 10 µ V 0.1 mV 1 mV 10 mV DC accuracy 0.03 % 0.02 % AC and AC+DC bandwidth 100 kHz 200 kHz AC and AC+DC basic accuracy 0.3 % 0.3 % VLowZ AC 500 kΩ DC. AC and AC+DC current Range 1,000 µA 10 mA 100 mA 1,000 mA 10 A 10 A / 20 A (30 s max) Resolution 10 nA 0.1 µA 1 µA 10 µA 100 µA 1,000 µA DC accuracy 0.01 % AC and AC+DC bandwidth 50 kHz AC and AC+DC basic accuracy 0.3 % Frequency Frequency range 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 5 MHz Resolution 0.0001 Hz 0.001 Hz 0.01 Hz 0.1 Hz 1 Hz 10 Hz 100 Hz Resistance and continuity Ranges 100 Ω* 1 kΩ 100 kΩ 1,000 kΩ 10 MΩ 50 MΩ Resolution 0.001 Ω 10 mΩ 100 kΩ 10 Ω 10 Ω 1 kΩ Basic accuracy 0.07 % Protection 1,000 V electronic protection Audible continuity detection 1,000 Ω calibre: SIGNAL <20 Ω < 3.5 V Diode test Voltage measurement 2.6 V diode < 1 mA + 0-20 V Zener diode or LED < 11 mA Capacitance Ranges 1 nF 10 nF 100 nF 1,000 nF 10 µF 100 µF 1 mF 10 mF Resolution 1 pF 10 pF 0.1 nF 1 nF 0.01 µ F 0.1 µF 1 µ F 10 µ F Temperature Pt100/1,000 Operating range -200 °C to +800 °C with Pt and -40 °C to +1,200 °C with K thermocouple Accuracy 0.1 % Other measurement functions SURV MAX / MIN / AVG On all the main positions measured REL REF relative value - delta unit or on 3 displays + main measurement PWM filter 300 Hz 4th-order low-pass filter for measurements on variable speed drives of asynchronous motors SPEC Display of measurement tolerance + Smin + Smax GRAPH Trend of main measurement < 60 s Secondary measurements 3 measurements + main measurement Measurement storage 1,000 6,500 General specifications Type of display Colour graphical display (70 x 52) with backlighting and black background on 4 x 100,000-count displays PC interfaces USB optical connector or Bluetooth - SX-DMM software Power supply Charger or 4 x AA batteries (or Ni-MH rechargeable batteries) Safety / EMC Safety as per IEC61010-1 (2001) 1,000 V CAT III - EMC as per EN61326-1 CEI 61010-2-033 - 1 000 V CAT III - 600 V CAT IV Environment Storage: -20 °C to +70 °C – Operation: -10 °C to +40 °C Mechanical specifications Dimensions (L x W x H): 196 x 90 x 47.1 mm / Weight: 570 g Warranty 3 years * Manual access aSYC Iv gRaPHICaL FaMILY DIgITaL MULTIMETERS multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr ACCESSORIES FOR MULTIMETERS Clamps for digital multimeters To avoid powering down the circuit, you are advised to measure the current with a current clamp with A or V output. The direct measurement function is implemented on the ASYC multimeters (Ax function). As the clamp function integrates a precise ratio xxxx.XA/xxxx.XV or XA, it is possible to connect a wide range of current clamps which you can find in the CHAUVIN ARNOUX Catalogue and on pages 96 to 101 of this document; however, you should check the input/output range of the clamp to ensure that it is compatible with the calibres offered by the multimeter. The accuracy of this "clamp" function depends on the accuracy of the clamp and of the calibre or range used on the multimeter. Selection guide Mini 02 Mini 03 Mini 05 Mini 09 General purpose AC current Products MINI02 MINI03 MINI04 MINI05 MINI06 MINI07 MINI08 MINI09 References P01105102Z P01105105Z P01120401/02 P01120415 P01120304/05 P01120560 P01120561 P01120504 Useful measurement range with the multimeter for use from 5 % to 100 % of the multimeter ranges MX24B 25 A to 100 A 12 A to 240 A Clamp performance Bandwidth 10 kHz 500 Hz 10 kHz 10 kHz 10 kHz 20 kHz 20 kHz 20 kHz Typical accuracy 1 % 3 % - 2 % 1 % 2 % 0.50 % 1 % 1 % 1 % Clamping diam. 12 mm 12 mm 20 mm 20 mm 52 mm 54 mm 80 mm 140 mm Output Direct readings Yes Yes Yes Yes Yes No Yes Yes 1 mA/A 1 mV/mA – 1 mV/A 1 mA/A 100 mV/A 1 mV/A 100 mV/A – 10 mV/A 10 mV/A – 1 mV/A 10 mV/A – 1 mV/A Connection Lead Lead Sockets/lead Lead Sockets/lead Casing, 19 mm spacing General purpose AC & DC current Leakage current Process Current transformer Products E6N PAC11 PAC20 MN73 K2 MN71 References P01120040A P01120068 P01120071 P01120421 P01120074A P01120420 Useful measurement range with the multimeter for use from 5 % to 100 % of the multimeter ranges MX24 / MX24B 25 mA – 80 Aac/dc 0.4 A to 600 Adc 25 A to 1,400 Adc 25 mA to 240 Aac 2.5 mA to 450 mAdc 250 mA to 12 A 0.2 A to 400 Aac 25 A to 1,000 Aac 25 mA to 240 Aac 2.5 mA to 300 mArms Clamp performance Bandwidth 2 kHz or 8 kHz 10 kHz 5 kHz 10 kHz 1.5 kHz 10 kHz Typical accuracy 2 % or 4 % 1.5 % - 2 % 2 % 1 % - 2 % 1 % 1 % Clamping diam. 11.8 mm 39 mm 39 mm 20 mm 3.9 mm 20 mm Output Direct readings Yes Yes Yes Yes No No
1 V/A – 10 mV/A 10 mV/A - 1 mV/A 1 mV/A 1 V/A - 10 mV/A 10 mV/A 100 mV/A
Connection Lead Lead Lead Lead Lead Lead
ACCESSORIES FOR MULTIMETERS On the ASYC IV MULTIMETERS, the CLAMP function integrates the transformation ratio in mV or mA/A according to the coupling selected. The measurement range of clamp will be adapted to match the measurement range of the multimeter. MTX3290 and MTX3291 fixed ratios: 1/1-1/10-1/100-1/1,000 mV/A List of the main clamps in our CHAUVIN ARNOUX range: ACCESSORIES FOR MULTIMETERs MN 08 MN 09 PAC 11 PAC 20 General purpose AC current Products MINI02 MINI05 MN08/09 MN89 C106/C107 MiniFLEX® MiniFLEX® AmpFLEX® References P01105102Z P01105105Z P01120401/02 P01120415 P01120304/05 P01120560 P01120561 P01120504 Useful measurement range with the multimeter for use from 5 % to 100 % of the multimeter ranges Clamp performance Bandwidth 10 kHz 500 Hz 10 kHz 10 kHz 10 kHz 20 kHz 20 kHz 20 kHz Typical accuracy 1 % 3 % - 2 % 1 % 2 % 0.50 % 1 % 1 % 1 % Clamping diam. 12 mm 12 mm 20 mm 20 mm 52 mm 54 mm 80 mm 140 mm Output Direct readings Yes Yes Yes Yes Yes No Yes Yes 1 mA/A 1 mV/mA – 1 mV/A 1 mA/A 100 mV/A 1 mV/A 100 mV/A – 10 mV/A 10 mV/A – 1 mV/A 10 mV/A – 1 mV/A Connection Lead Lead Sockets/lead Lead Sockets/lead Casing, 19 mm spacing General purpose AC & DC current Leakage current Process Current transformer Products E6N PAC11 PAC20 MN73 K2 MN71 References P01120040A P01120068 P01120071 P01120421 P01120074A P01120420 Useful measurement range with the multimeter for use from 5 % to 100 % of the multimeter ranges MTX 3290 / MTX 3291 6 mA to 80 A 60 mA to 600 A 6 A to 1,400 Adc 60 mA to 240 A 6 mA to 450 mAdc 60 mA to 12 A 1,000 Aac 6 mA to 3.3 Aac MTX 3292 / MTX 3293 5 mA to 80 A 10 mA to 600 Adc 1 A to 1,400 Adc 10 mA to 240 A 1 mA to 450 mAdc 10 mA to 12 A
1 A to 400 Aac 1 A to 1,000 Aac 1 mA to 300 mAac
Bandwidth 2 kHz or 8 kHz 10 kHz 5 kHz 10 kHz 1.5 kHz 10 kHz Typical accuracy 2 % or 4 % 1.5 % - 2 % 2 % 1 % - 2 % 1 % 1 % Clamping diam. 11.8 mm 39 mm 39 mm 20 mm 3.9 mm 20 mm Output Direct readings Yes Yes Yes Yes No No Connection Lead Lead Lead Lead Lead Lead A110 (AmpFlex®) MA110 (MiniFlex®) multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr LaBORaTORY MULTIMETERS MX 5006 & MX 5060 A tried and tested casing Lightweight and compact Multidirectional handle for positioning as you wish. A casing which is can be stacked on your lab bench to save space. The mains lead can be wound round the "feet" for easy storage. A display (890 x 450 mm) Optimized over the whole height of the casing to offer comfortable reading with 16 mm digits on the main display above a second simultaneous display. The transflective LCD screen with backlighting provides a wider viewing angle making it visible whatever the conditions. A double 60,000-count display plus an analogue view by means of a bargraph. Top performance 0.05 % accuracy and AC, DC or AC+DC TRMS measurements, as required, as well as AUTO or manual ranges to optimize your measurements. Extended functions Equipped with all the traditional functions (voltage, current, resistance, continuity, diode test), these multimeters also offer extended functions: measurement of capacitance, frequency, period and ΔREL relative. Values expressed as values and in %. Measurements in total safety for electrical engineering applications with 1,000 V CAT III protection: a V LowZ low input impedance mode for stable measurements by eliminating "stray" voltages plus a PWM filter selectable for your measurements on variable speed drives (asynchronous motors). Monitoring of your measurements with MIN / MAX (100 ms) / PEAK (1 ms) recordings to capture any faults. The 3 terminals limit handling errors with complete current autoranging from 50 µ to 20 A. The MX 5060 is equipped with a USB interface for remote programming and processing of the data by our SX-DMM software for multimeters. A simple, precise mechanical switch for selecting the main quantity and a secondary function key marked in colour. V A MX5006
Standard state at delivery
1 MX: 1 mains power cable, 1 set of
2 measurement leads, 1 user manual References to order MX5006: 6,000-count benchtop TRMS multimeter MX5060: 60,000-count benchtop TRMS USB multimeter Available accessories See pages 97 to 106 For further details… LABORATORY MULTIMETERS n A compact, lightweight casing n A particularly easy-to-read display with widened viewing angle and digits 16 mm high n Current measurement with a single current terminal up to 10 A n MX5060: USB communication and programming with the SCPI protocol Simple and effective. MX5060 METRIX benchtop multimeters: laboratory instrumentation reinvented Specifications MX 5006 MX 5060 Resolution 6,000 counts 60,000 counts Display Transflective LCD Backlighting Widened viewing angle DC. AC and AC+DC TRMS voltage Ranges 600 mV to 1,000 V 60 mV to 1,000 V DC basic accuracy 0.09 % 0.05 % Useful bandwidth 100 kHz DC, AC and AC+DC current Ranges 6,000 µA to 10 A (20 A 30 s) AC and AC+DC basic accuracy 1 % DC basic accuracy 0.80 % Frequency measurements Ranges 60 HZ to 60 kHz Other measurements Period PWM filter Resistance and continuity Ranges 600 Ω to 60 MΩ Basic accuracy 0.40 % 0.20 % Audible continuity test 600 Ω range - threshold < 30 Ω Diode test 0 to 3 V Capacitance 6 nF to 60 mF Temperature with K thermocouple -200 to +1,200 °C Communication USB Other measurements SURV (MIN/MAX) and Peak +/- / ΔREL Additional functions HOLD and AUTO
300 Hz filter
IEC61010-1 safety 1,000 V CAT III Dimensions (H x L x W) / Weight 295 x 270 x 95 mm / 1.85 kg Warranty 3 years multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr SX-DMM Software List of controllable multimeters n MX 26, MX 53, MX 54, MX 56, MX 57, MX 58, MX 59 n MX 554, MX 556, MX 5060 n MTX 3250 n MTX 3281, MTX 3282, MTX 3283 n MTX 3291, MTX 3292, MTX 3293 The Math functions: XY, differential, integral, curve smoothing Data export into EXCEL for processing in a spreadsheet This software can be used to communicate with our multimeters via an RS232, USB or BLUETOOTH link, depending on the model: This software can be used to communicate with our multimeters via an RS232, USB or BLUETOOTH link, depending on the model: SX-DMM, the software for acquiring, recording and pro- cessing the measurements from 1 to 4 multimeters simul- taneously. Each channel must be assigned to a COM or USB serial port for connection to be possible. Several SX- DMM sessions can be opened at the same time on a PC. The trigger mode and acquisition intervals can be set from 100 ms upwards and the clock can be managed automatically, depending on the model. ACCESSORIES FOR MULTIMETERS This data acquisition software can be used to link up to 4 controllable multimeters, whether they are on-site or benchtop models. PC data acquisition software for multimeters Reference to order SX-DMM2: software for multimeters This software transforms your multimeter(s) into a power monitor with up to 4 channels for point testing
MX 57EX-CAL & HX 0059 Metrology software List of multimeters supported and associated software n MTX3291 and MX5060 (after opening the casing) The various versions of this software help you to perform periodic testing and/or calibration of your instruments with the "casing closed" via their RS or USB serial communication interface (depending on the model), simply and effectively. Without needing to research the technical details of the instrument, users can execute "manufacturer" procedures or develop their own procedures, in compliance with the Quality monitoring standards, while ensuring in particular the reverse traceability of their processes, saving their data and printing out reports. Regulatory and connection information Creation/modification of procedures Saving and/or printing of reports Execution of the procedure and instructions for the operator ACCESSORIES FOR MULTIMETERs multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr ACCESSORIES FOR MULTIMETERS n The common software for all METRIX® multimeters: SX-DMM2 n Instrument drivers for LabView and LabWindows CVI The multimeters are available in the Support section of our website, as are the USB drivers of our accessories: HX0055 and HX0056 Communication accessories and software The multilingual SX-DMM2 communication kit is easy to use with the MX 26 for data acquisition on PC Description References to order Multimeters MX 58HD, MX 59HD Serial link kit for ASYC2 HD version SX-ASYC2HD Acquisition software for ASYC2 SX-DMM2 MX 58HD, MX 59HD ASYC2 family calibration software SX-ASYC2C/B MX 57Ex MX 57Ex calibration software MX57EX-CAL MTX 3281, MTX 3282, MTX 328X V1.0 calibration software HX0059 MTX 3283, MTX 329X Optical / USB cable HX0056-Z Bluetooth / USB adapter for PC P01637301 Communication kit with software HX0050 MX 55, MX 556 Calibration software for MX 553 & MX 556 SX-ASYC2C/B Software for MX 553 & MX 556 SX-DMMBT/B MX 5060 USB A-USB B cable P01295293 MTX 3292, MTX 3293 ASYC4 100K calibration software HX0059B MTX 3291, MX 5060 "Open casing" calibration kit P01196770 All models USB/RS232 adapter for PC HX0055 HX0056-Z: USB cable for MTX 328x and MTX 329x multimeters
Specifications MX 350 MX 355 MX 650 MX 655 MX 670 MX 675 DC current • • • RMS/TRMS measurement • • • Clamping ø 26 mm • Clamping ø 30 mm • Clamping ø 36 mm • Clamping ø 40 mm • • Clamping ø 42 mm • 4,000-count display • • • • 10,000-count display 2 2 Backlighting • • Bargraph • • • • AC current 400 A 400 A 1,000 A 1,000 A 1,000 A 1,000 A DC current 400 A 1,000 A 1,400 A AC voltage 600 V 600 V 750 V 750 V 1,000 V 1,000 V DC voltage 600 V 600 V 1,000 V 1,000 V 1,400 V 1,400 V Audible continuity • • • • • • Diode and semi-conductor tests • • Temperature • • ΔZero or ΔREL • • • • Range • • Automatic power-off • • • • • •
300 V CAT III • •
600 V CAT III • •
1,000 V CAT III • •
600 V CAT IV • •
ACCESSORIES FOR MULTIMETERS ClAmP multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr POCkET CLAMP MULTIMETERS MX 350 & MX 355 n Compact, ergonomic clamp multimeters n Current measurement up to
400 AAC (MX 350) or 1,000 A
and 1,000 Aac&dc (MX 355) n AC & DC voltage measurement up to 600 V n Resistance and continuity measurement n Frequency measurement (MX 350) n Automatic zero DC (MX 355) n LCD screen with bargraph Comprehensive: all the functions needed by electricians in one hand. References to order MX0350-Z: 1 MX 350 clamp MX0355-Z: 1 MX 355 clamp Standard state at delivery
1 MX 35x clamp multimeter delivered
with 1 set of measurement leads with test probes, 1 soft case, 2 x 1.5 V AAA alkaline batteries and 1 user manual in 5 languages Available accessories See pages 97 to 106 HzV A Specifications MX 350 MX 355 Display 4,000 counts Bargraph 42 segments Clamping diameter 26 mm 30 mm Type of acquisition AVG Range selection Automatic Automatic or Manual AC current 0.05 A to 400.0 A Basic accuracy 1.9 % +5 D 2% of reading + 10 D Bandwidth 50 to 500 Hz DC current - 0.1 A to 400 A Basic accuracy - 2.5% of reading + 10 D AC voltage 0.5 V to 600 V Basic accuracy 1.5% of reading + 5 D Bandwidth 50 to 500 Hz DC voltage 0.2 V to 600 V Basic accuracy 1% of reading +2 D Resistance 0.2 to 399.9 Ω Basic accuracy 1% of reading + 2D Audible continuity ≤ 40 Ω Frequency Current: 20 Hz to 10.00 kHz Voltage: 2 Hz to 1 MHz Basic accuracy 0.1% of reading + 1D Fonctions Hold Hold ΔZero Range Automatic shutdown 30 min. 30 min., can be deactivated Power supply 2 x 1.5 V (AAA) Electrical safety CAT III 300V / CAT II 600V Dimensions / Weight 193 x 50 x 28 mm / 230 g
For further details… MX 650 & MX 655 n Clamps for measuring high currents and voltages n Current measurement up to 1,000 A ac (MX 650) or 1,000 Aac and 1,000 Aac&dc (MX 655) n AC & DC voltage measurement up to 1,000 V n Resistance, continuity and frequency measurements n RMS measurements (MX 655) n Min-Max and Peak 1 ms analytical functions n Differential current, voltage and resistance measurements Suitable for maintenance of electric machines. References to order MX0650-Z: 1 MX 650 MX0655-Z: 1 MX 655 Standard state at delivery
1 MX 65x clamp multimeter delivered
with 1 set of measurement leads with test probes, 1 soft case, 1 x 9 V alkaline battery and 1 user manual in 5 languages 1,000 a CLAMP MULTIMETERS Available accessories See pages 97 to 106 HzV A Specifications MX 650 MX 655 Display 4,000 counts Bargraph 42 segments Clamping diameter 36 mm 40 mm Type of acquisition AVG RMS Range selection Automatic or manual Automatic AC current 0.05 A to 1,000 A Basic accuracy 1.9% of reading + 5 D Bandwidth 50 Hz to 1 kHz DC current - 0.10 A to 1,000 A Basic accuracy - 2.5% of reading + 10 D AC voltage 0.5 V to 750 V Basic accuracy 2.5% of reading + 10D Bandwidth 50 Hz to 1 kHz DC voltage 0.2 V to 1,000 V Basic accuracy 0.75% of reading + 2 D 1% of reading + 2 D Resistance 0.2 to 4,000 Ω Basic accuracy 1% of reading + 2 D Audible continuity ≤ 100 Ω Diode test and semi- Itest ≤ 0.6 mA / Vtest ≤ 3.3 Vdc I test ≤ 1.7 mA / Vtest ≤ 6 Vdc conductor junction test Frequency Current: 20 Hz to 10 kHz Voltage: 10 Hz to 10 kHz Basic accuracy 0.1% of reading + 1 D ΔREL. Range Max-Min. ΔREL Automatic shutdown 30 min., can be deactivated Power supply 1 x 9 V 6LF22 battery Electrical safety IEC 61010-1, IEC 61010-2-032, IEC 61010-2-033 - 600_V CAT III Dimensions / Weight 246 x 93 x 43 mm / 400 g ClAmP multimEtERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr DUaL-DISPLaY TRMS CLAMP MULTIMETERS MX 670 & MX 675 n 2 simultaneous TRMS measurement channels n Dual 10,000-count backlit display n CAT IV 600 V n Voltage up to 1,400 V n Temperature measurement Extra protection for industry and electrical power distribution. Specifications MX 670 MX 675 Clamping diameter 42 mm 40 mm Display 2 x 10,000 counts / backlighting Type of acquisition TRMS AC/DC Range selections Automatic AC current 0.05 A to 1,000 A Basic accuracy 1.5 % of reading +5 D Bandwidth 50 Hz to 3 kHz DC current 0.10 A to 1,400 A Basic accuracy 1.2 % of reading +5 D AC voltage 0.5 V to 1,000 V Basic accuracy 1 % of reading +5 D Bandwidth 50 Hz to 3 kHz DC voltage 0.2 V to 1,400 V Basic accuracy 1 % of reading +2 D Resistance 0.2 to 9,999 Ω Basic accuracy 1% of reading + 3 D Audible continuity ≤ 35 Ω Temperature -40.0 °C to +1,200 °C / -40 °F to +2,192 °F Basic accuracy 1% of reading + 3 D Frequency Current: 0.2 Hz to 9,999 Hz Voltage: 10 Hz to 9,999 Hz Basic accuracy 1% of reading + 2 °C / 1% of reading + 4 °F Functions Hold Hold Peak (1 ms) Peak (1 ms) Min (500 ms) Min (500 ms) Max (500 ms) Max (500 ms) ΔZero Automatic shutdown 10 min., can be deactivated Power supply 1 x 9 V 6LF22 battery Electrical safety IEC 61010-1. IEC 61010-2-032. IEC 61010-2-033
600 V CAT IV / 1,000 V CAT III
Dimensions / Weight 272 x 80 x 43 mm / 480 g 257 x 80 x 43 mm / 440 g References to order MX 675: MX0675 MX 670: MX0670 Standard state at delivery
1 MX 670 or MX 675 clamp multimeter
delivered with 1 x 9 V alkaline battery, 1 user manual in 5 languages, 1 soft case, 1 set of leads with Ø 4 mm test probes and K-thermocouple sensor Available accessories See pages 97 to 106 For further details… HzV A
PX0110 : PX 110 wattmeter PX0120: PX 120 wattmeter HX0011: wattmeter switch HX0012: multi-ratio transformer HX0013: Wattcom software + RS232 cable HX0021: PX 110 and PX 120 mains power supply P01330401: USB cable P03295509: accessory for current measurement Accessories HX 0011 wattmeter switch This makes it possible to use the two watt- meter method with a single wattmeter. This allows measurements on unbalanced 3-wire 3-phase systems. The polarity reversal switch contains auxiliary contacts ensuring conti- nuity of the current circuits during switching operations. The following measurements are possible for frequencies of 50 to 60 Hz: - AC voltages from 10 to 600 V, - AC currents from 0 to 20 A HX 0012 multi-ratio transformer This can be used for measurements on loads whose power consumption is higher than the specifications of the wattmeter used. The following measurements are possible for frequencies of 50 to 60 Hz: - AC voltages from 10 to 600 V, - AC currents from 0 to 30 A Wattcom Multilingual data acqui- sition and processing software for viewing different quantities on a PC screen, printing screenshots or trans- ferring measurement files into a spreadsheet and storing them. Accessories supplied with the Wattcom software RS232 optical cable For further details… PX 110 & PX 120 PX 110 n Single and three-phase TRMS digital wattmeter PX 120 n Single-phase TRMS digital wattmeter Designed for general and technical education, installers and industrial maintenance teams, the PX 110 and PX 120 digital wattmeters can be used both on-site and in the laboratory. Specifications PX 110 PX 120 Network type Single-phase Single and three-phase Number of display counts 3 lines of 4 digits Bandwidth DC to 1 kHz AC/DC active power 6 kW Resolution 0.1 - 1 W AC/DC basic accuracy 2 % R ± 3 D 1 % R + 2 D Apparent power (VA) 10 VA to 1 kVA Reactive power (var) 1 VAR to 6 kVAR Resolution 0.1 to 1 AC/DC basic accuracy 2 % R ± 2 D Power factor 1 Resolution 0.01 / 3 % R ± 2 D AC/DC voltage 500 mV to 600 Vrms Resolution 100 mV AC/DC basic accuracy 1 % R ± 3 D 0.5 % R + 2 D Current 10 mA to 10 ARMS Resolution 1 to 10 mA AC/DC basic accuracy 1 % R ± 3 D 0.5 % R + 2 D Inrush current 5 to 65 A (peak) Resolution/accuracy 100 mA / 10 % R ± 2 D IEC 61010 safety 600 V, Cat. III, pol.2 Interface and software Yes – RS232 optical link (option) Auto power-off After 10 minutes Power supply 6 x 1.5 V Dimensions 60 x 108 x 211 mm Weight 835 g Accessories supplied 2 current cables and 2 voltage cables, 2 test probes, 6 batteries and 1 user manual ON-SITE wATTMETERS V A W VA var tEStERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr MX 125 & MX 135 n Equipped with a moving-coil galvanometer: - Safety: IEC61010 - 600 V CAT III - Ingress protection: IP65 Designed to withstand mechanical shocks, protected by high-rupture- capacity fuses. Analogue voltmeter and ammeter TRAINING EQUIPMENT DISDaSCOPES - vOLTMETERS - aMMETERS Standard state at delivery MX125: 1 MX voltmeter and user manual MX135: 1 MX ammeter and user manual References to order MX125: MX125 voltmeter MX135: MX135 ammeter Available accessories See pages 97 to 106 V A Specifications MX 135 Idc Ranges 7 (50 µA, 500 µA, 5 mA, 150 mA, 500 mA, 1.5 A, 10 A) Accuracy 2 % Protection 10 A and 1.6 A fuses (HRC 600 V) Iac Ri 1.2 kΩ Ranges (V) 6 (500 µA, 5 mA, 150 mA, 500 mA, 1.5 A, 10 A) Accuracy 2.5 % Protection 10 A and 1.6 A fuses (HRC 600 V) Specifications MX 125 Vdc Ranges 9 (150 mV, 0.5 V, 1.5 V, 5 V, 15 V, 50 V, 150 V, 500 V, 1,500 V) Accuracy 2 % Ri 20 kΩ/V Vac Ranges (V) 6 (5, 15, 50, 150, 500, 1,500) Accuracy 2.5 % Ri 6.32 kΩ/V Specifications MX 125 MX 135 Length of scale 83 mm Bandwidth 16 to 1 kHz Voltage 9 DC calibres (150 mV to 1,500 V)
6 AC calibres (5 mV to 1,500 V
Current 7 DC calibres (50 µA to 10 A)
6 AC calibres (500 µA to 10 A)
Ri 20 kΩ Dimensions / Weight 155 x 99 x 40 mm / 350 g
ON-SITE ELECTRICAL SAFETY TESTERS Electrical installation testing The purpose of electrical safety testing is to ensure the safety of people and property in the event of a fault on the installation. It can also be used for preventive maintenance, thus avoiding serious failures. To guarantee safety, the CENELEC HD 384 standard specifies the requirements applicable to electrical installations in buildings, with the following measurements in particular: Earth measurement with stakes The earth stake must have a resistance lower than 100 Ω to allow any faults to drain to earth. When there is sufficient room to set up stakes, this measurement can be performed using the 3P method with stakes, also known as the "62 % method". The earth bar must be disconnected during this measurement. Earth measurement without stakes by measuring the earth loop When the 62 % method is not applicable, you can use the stakeless method which involves measuring the earth loop. This measurement can be performed on live installations and does not require any stakes. This method provides an overall value rounded up from the real earth value. Continuity measurement The continuity of the protective conductors is measured with a test current of at least 200 mA. The resistance measured must be below a threshold which is usually 2 Ω. Insulation measurement Insulation measurement, usually performed between active conductors and the earth, involves applying a
250 V, 500 V or 1,000 V
dc test voltage, depending on the operating voltage of the installation. The insulation resistance value must be at least 1 kΩ per volt of the test voltage (usually 500 kΩ /1 MΩ). Residual Current Device testing At least one pulse-mode trip test must be performed on the RCDs on the installation to check the trip time. Other test and measurement operations Current measurement using a clamp coupled to an installation tester helps to detect existing leakage, as well as possible phase unbalance on three-phase installations. You are also advised to test the lightning arresters to ensure that they will do their job in the event of a voltage surge due to lightning on the installation. tEStERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr ON-SITE ELECTRICAL SAFETY TESTERS MX 406B MX 604 n Insulation measurement at 50, 250 and 500 Vdc n Voltage measurement up to
440 Vac/dc
n Continuity (200 mA) n Quick and easy readings with the colour-scale dial n Hands-free use with remote control probe n Lightning-arrester support module for measurements on unmounted lightning arresters n Probe with remote-control button for in-situ measurements n Measures insulation resistance at 50, 100 and 500 V dc n Quick and easy readings with the colour-scale dial Lightning arrester tester. Reference to order MX0604: 1 MX 604 tester Reference to order MX0406B: 1 MX 406B tester Standard state at delivery
1 MX 604 delivered in a hard case with 1 detachable lightning-arrester support
module, 1 remote-control probe, 1 red test probe, 1 black straight-straight lead 1.5 m long with built-in test probe, 1 black crocodile clip, 1 lightning-arrester support clamp, 1 strap mounted on the instrument, 3 batteries, 1 user manual in 5 languages Standard state at delivery MX406B: 1 MX 406B tester delivered with 1 remote-control probe, 1 black safety lead, 1 black crocodile clip, 3 x 1.5 V batteries and 1 user manual Available accessories See pages 97 to 106 Analogue insulation tester Insulation tester For further details… V Specifications MX 406B Insulation 10 kΩ to 200 MΩ at 50/250 and 500 Vdc (3 ranges) Continuity with buzzer 0 to 10 Ω (i > 200 mA dc) Voltage 0 to 440 Vac/dc Electrical safety IEC 1010 – 300 V CAT III Power supply 3 x 1.5 V batteries for 1,000 x 5 s measurements Dimension / Weight 155 x 98 x 40 mm / 410 g Specifications MX 406B Lighting arrester test 0 to 600 Vdc Insulation 100 kΩ to 2,000 MΩ at 50/100 and 500 Vdc (3 ranges) Battery test Yes Electrical safety IEC 1010 – 300 V CAT III Power supply 3 x 1.5 V batteries for 1,500 x 5 s measurements Dimension / Weight 155 x 98 x 40 mm / 350 g
For further details… MX 407 n Insulation at 250 / 500 / 1,000 V n AC or DC voltage measurement up to 600 V n Insulation resistance up to 4 GΩ n Continuity with 200 mA test current n Dual analogue and digital display on wide backlit screen With the MX 407, you get two tools in one as it is a megohmmeter equipped with all the functions of a multimeter as well. Reference to order MX0407: 1 MX 407 tester Standard state at delivery
1 MX 407 insulation tester delivered in
"hands-free" bag with 1 set of leads 1.5 m long (red/black), 1 black test probe, 1 red crocodile clip, 6 x 1.5 V AA batteries and 1 user manual in 5 languages On-sITE ELECTRICAL SAFETY TESTERS Insulation tester Available accessories See pages 97 to 106 V Specifications MX 407 Voltage Range 0 to 600 Vac/dc Accuracy ±0.8 % ± 3 cts (DC) ±1.2 % ± 10 cts (AC) Insulation Test voltage 250 V 10 kΩ to 4 GΩ
500 V 10 kΩ to 4 GΩ
1,000 V 10 kΩ to 4 GΩ Accuracy Range 4 MΩ/40 MΩ ±2 % ±10 cts Range 400 MΩ ±2 % ±5 cts Range 4 GΩ ±4 % ±5 cts Voltage alert indicator Yes > 25 V Test inhibition Yes > 25 V Continuity Range 0 to 400 Ω Measurement current > 200 mA Cable compensation Yes Buzzer Buzzer triggered if < 35 Ω ± 3 Ω Resistance Range 0 to 400 kΩ Accuracy ±1.2 % ± 3 cts Automatic power-off After 10 minutes without use Display / Backlighting LCD + bargraph / Yes Power supply 6 x 1.5 V AA batteries Electrical safety IEC 61010 600 V CAT IV / / IEC 61557-3-4 Dimensions / Weight H 200 x L 92 x W 50 mm / 700 g (with batteries) tEStERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr MX 435D n Compact and lightweight, ideal for intensive use n Earth measurement without stakes by measuring the earth loop n 3-wire lead with 2P+E plug for quick, error-free measurement on the installation n Powered by rechargeable battery (batteries and charger supplied) n Immediate error-free connection thanks to colour-coding of the terminals and the switch n Continuity with buzzer and fuseless protection against external voltages Quick, simple testing of electrical installations in compliance with the CENELEC HD 384 (NF C 15-100) standard. Specific accessories Adapter for MX435D loop MN73 200 Aac / 2 Aac current clamp P01120421 Earth kit: P01102019 Standard state at delivery
1 MX 435D delivered in a hands-free bag, 1 set of 2
measurement leads 1.5 m long (red/black), 2 crocodile clips (red/black), 2 test probes (red/black), 1 battery charger, 1 measurement lead with European mains plug and 1 user manual Available accessories See pages 97 to 106 Multi-function installation tester For further details… The complete 50 m earth kit Reference to order MX0435D ON-SITE ELECTRICAL SAFETY TESTERS V A
3P earth 0.10 to 1,999 Ω (2 calibres) Earth loop 0.10 to 1,999 Ω (2 calibres) Continuity + buzzer 0.10 to 19.99 Ω (i > 200 mAdc) Insulation 0.5 to 199.9 MΩ at 500 Vdc RCD test Test calibres 30 mA / 100 mA / 300 mA / 500 mA / 650 mA Type of test Pulse Current (with clamp option) 1 mA to 200 A Electrical safety IEC 1010 – 300 V CAT III - IEC 61557 1-2-4-5-6 Power supply Rechargeable battery (as standard) Possibility of operation with 2 x 9 V batteries Dimensions 195 x 97 x 55 mm Weight 670 g CHAUVIN ARNOUX: A CERTIFIED TRAINING ORGANIZATION SINCE 1993 CERTIFICATION No. 11.92.06217.92 The Chauvin Arnoux Group proposes six training modules, each lasting one day. Whether for theoretical training or hands-on practical sessions, you can trust the market leader to train you and your staff. ELECTRICAL INSTALLATIONS AND NF C 15-100 STANDARD (1 day)
- Properties and goals of earth connection systems
- Behaviour of earth connection systems regarding harmonics
- Insulation resistance measurement
- Electrical continuity measurements on protective conductors
- Resistance measurements on earth connections
- RCD testing www.chauvin-arnoux.com/fr/guides www.chauvin-arnoux.com tEStERS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr aNaLOgUE OSCILLOSCOPES Introduction Choosing your analogue oscilloscope Analogue oscilloscope with cathode ray tube This is an instrument for "qualitative analysis" which can be used to view the waveform of a periodic electrical signal as a function of time. Vertical deflection Deflection coefficient This defines the minimum amplitude (sensitivity) and maximum amplitude values accepted by the input Y. Bandwidth (BW) This is the maximum admissible frequency range for the oscilloscope (MHz). Rise time (rt) For a square signal (steep edges), this is the time necessary for the rising edge to pass from 10 % to 90 % of the "peak to peak" amplitude. Horizontal deflection Time base (TB) It is the oscilloscope's circuits which control the screen sweep. The choice of the "time base coefficient" enables the signals to be displayed over an appropriate duration. Alternate or Chop display Multiplexing of the channels allows display of several channels, Y1, Y2, … Y4, with a single electron beam. In alternate mode, each of the traces performs a complete sweep of the screen, alternately. For slow speeds, portions of the trace to be displayed during a given screen sweep are cut up: chop mode. Deflection coefficient This defines the minimum amplitude (sensitivity) and maximum amplitude values accepted by the input Y. Trigger This is a circuit which authorizes the horizontal sweep and determines the signal's starting point. The "trigger level" is the voltage level which must be reached by the signal observed in order to sweep. Alternate triggering provides stable display of the traces in all cases. XY function This is a function which allows display of one channel (Y1) as a function of another channel (Y2) on screen; the time base is then inoperative.
Choosing your digital oscilloscope This is an instrument which allows users to view, as a function of time, the waveform of a periodic electrical signal or a single event. because it is based on digital processing, it allows storage of the signals and automatic measurements and transfer of the data onto a PC. Sampling frequency (or rate) This is the reciprocal of the sampling interval and it is expressed in MegaSamples per second (MS/s). It varies according to the sweep speed. According to Shannon's theorem, for a pure sinusoidal signal, this frequency must be at least twice the frequency of the signal to be observed. In practice, the oscilloscope must sample at a frequency at least 10 times the presumed frequency of the signal. The "useful bandwidth" will be one tenth of the maximum sampling frequency and will be expressed in MegaHertz. Sampling modes For "real-time" or "one-shot" sampling, all the samples are acquired in a single sweep. "Equivalent time" sampling can be used to achieve higher "sampling frequencies" because the samples are acquired in several successive sweeps. This mode is reserved for periodic signals. Deflection coefficient This defines the minimum amplitude (sensitivity) and maximum amplitude values accepted by the input Y. Memory depth This is expressed in kilo points (kpoints). It determines the "recording duration" according to the sweep speed; the larger it is, the longer the recording duration. Conversely, an instrument with ten times more memory capacity can sample 10 times quicker for the same recording duration. Vertical resolution "Quantification" involves converting the value of a sample into a binary number. The vertical resolution is defined by the capacity in bits of the Analogue/ Digital Converter (ADC). It is 1/256 or 0.4 % for an 8-bit ADC (28 = 256). Signal processing This involves very useful mathematical operations between signals: +, -, *, and even complex functions (Fourier transform or FFT, harmonic analysis, etc.). DIgITaL OSCILLOSCOPES oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr The different types of "measurement" inputs on oscilloscopes Traditional metal BNC inputs Class 1 unisolated oscilloscopes The inputs of traditional unisolated oscilloscopes are equipped with BNC connectors. They comprise a "hot point" connected to the central conductor of the BNC and a "cold point" connected to the metal enclosure of the BNC. 4 mm banana safety inputs Class 2 double-insulated oscilloscope with channels not isolated from one another The inputs of double-insulated oscilloscopes are equipped with two 4 mm banana plugs, one for the hot point and the other for the cold point or reference. The cold point or reference is isolated from the earth, so it is floating. When an oscilloscope has several channels (OX 71), the cold points or references of the channels are linked together and isolated from the protective earth. In these oscilloscopes, it is possible to have a cold-point / reference potential different from the potential of the protective earth. 4 mm banana safety inputs Class 1 differential oscilloscopes The inputs of differential oscilloscopes have two 4 mm banana plugs per channel: one for the + hot point and the other for the - hot point. The 2 hot points (+ and -) are equivalent because they have the same impedance in relation to the earth. If the oscilloscope has several channels, all the + and - hot points have the same impedance in relation to the earth. BNC safety inputs with metal enclosures insulated during use Class 2 double-insulated oscilloscopes with channels isolated from one another The inputs of double-insulated oscilloscopes with channels isolated from one another are equipped with BNC connectors with metal enclosures insulated when the measurement lead is connected. The cold point or reference is isolated from the earth and the cold points or references of the other channels. The inputs on our portable oscilloscopes Thanks to the independently isolated channels and the floating inputs, the SCOPIX and HANDSCOPE models can perform genuinely differential measurements. One input can measure the voltage between the two signal wires, while the other measures the difference in potential in common mode in relation to the earth, simultaneously and independently. Oscilloscopes with isolated channels are recommended when you are seeking to measure various electrical signals of different types. DIgITaL OSCILLOSCOPES
Channels (number/type) IEC61010 safety Analogue display or equivalent One-shot digital sampling ETS repetitive mode Vertical resolution Detection of transients (Glitch) Scaling / Physical unit PC communication via Ethernet 10Mb Ethernet + Web server Mains power supply / Battery Integrated mode "Oscilloscope" specifications Max. input sensitivity Max. input amplitude Analogue filter Time base (per division) Roll mode/ XY mode Memory depth Acquisition memory No. of reference or math curves on screen Envelope/Averaging modes SPO (Smart Persistence Oscilloscope) Automatic measuremens/Cursors Pulse trigger on width/number Video trigger (line counter) Trigger on measurement & Automatic backup Adjustable Hold-Off / Delay Calculation functions + - / x / : / Advanced Autoset with selection of channels Other functions Spectral analysis, FFT Lin & Log TRMS multimeters Harmonic analysis Threshold recorders (no. of channels) Power / Power harmonics measurement General specifications LCD colour screen / B&W / Tube 100% "closed casing" soft calibration" ScopeNet PC web server/ANDROID app Pages In@box Lab Training Lab Remote screen Analogue MTX 1052 MTX 1054 MTX 162 MTX 112 OX 71 OX 803B OX 530
200 MHz 60 MHz 10 MHz 5 MHz 30 and 40 MHz
2 or 4 /class 1 2 /class 1 2 /Differential 1 + X / isolated 2 / class 1 CATII 300V CATII 300V CATII 600V CATII 400V CATII 300V
200 MS/s 50 MS/s 50 MS/s - -
100 GS/s 20 GS/s 20 GS/s - -
- - - OX-REC OX OX 2.5 mV/div 5 V/div 20 mV/div 50 mV/div 1 to 5 mV/div
100 V/div 100 V/div 100 V/div 5 V/div 5 to 20 V/div
15 MHz, 1.5 MHz, 5 kHz 15 MHz, 1.5 MHz, 5 kHz - 20 MHz (1) 1 ns-200 s 5 ns-100 s 100 ns-200 s 500 ns-0.5 s "5 or 10 ns 0.1 or 0.2 s" 50 k / channel 50 k / channel 50 k / channel - - PC hard disk PC hard disk PC hard disk - - 4 2 2 - - - - - - -
- • • - -
- /• - - - -
- - - - • - - - - - - - - - -
- • • - • 9 bits / 54 dB 8 bits / 48 dB 8 bits / 48 dB - - - - - - - 31 orders - - - - 2 or 4 - - - - - - - - - PC screen PC screen PC screen -/-/• -/-/•
- • • - -
- /• - - - - 54-55 52 53 56 56 aNaLOgUE & IN@BOX OSCILLOSCOPES Selection guide oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr DIgITaL OSCILLOSCOPES SCOPEin@BOX screenless oscilloscopes PC ergonomics and environment The MTX 1052-PC, MTX 1054-PC & MTX 162 are genuine "scopes in a box". Compact, lightweight and stackable, these measuring instruments can be connected directly to a PC via a USB or Ethernet interface with dedicated PC software. The Wifi versions now allow wire- less Ethernet communication. Users benefit from all the PC's advantages in terms of storage capacity (PC storage capacity) and dis- play (minimum resolution 1024x768), allowing more precise analysis of the curves. The functions are directly accessible from the menus and the Windows toolbar by means of keyboard shortcuts or the mouse. Users control the oscilloscope using the "instrument" control panel, which contains all the commands found on normal oscilloscopes. Online help is also available. Multi- windowing enables simul- taneous dis- play of the traces, the zoom, the FFT analysis and the measure- ments... In this way, users can obtain multiple combinations and check out all the relevant infor- mation at a glance. The MTX 1052 & MTX 1054 offer the SPO (Smart Persistence Oscilloscope) display mode. This prin- ciple combines the advantages of analogue and digital oscilloscopes. It can be used to manage the display and acquisitions simultaneously, making it possible to increase the acquisition rate to several tens of thousands per second. With SPO, users can detect brief events, instabilities and untimely anomalies. The MTX 162, an oscilloscope with a "double time base", allows both normal display and remanent display (like on an analogue oscilloscope). Universal communication Each oscilloscope benefits from a univer- sal USB communica- tion mode and a 10 Mb Ethernet interface for integration in a local or remote network. When started up in USB or ETHERNET mode, the software automatically detects the instruments connected to the PC or to the network. "Unlimited" storage of the traces is possible simply by saving the files. Firmware upgrades are automatic. It is also possible to export results into Excel or print in Word with just 1 or 2 clicks. SCOPEin@BOX control panel. General commands SCOPEin@BOX Display of "X(t)" traces in SPO mode MTX105X: ScopeNet for Android tablets and smartphones can be downloaded free from Google Play The "W" versions of the SCOPEin@ BOX models offer built-in Wifi communication.
Oscilloscopes connected to a PC DIDASCOPES PC ergonomics and environment The DIDASCOPEin@BOX simplified PC software automatically detects the oscilloscope connected to the PC's USB port and starts it up. The software auto- matically opens a control panel and a trace window. The "READY" LED on the front panel switches off when the PC has taken control of the instrument. Simple to use Autoset and Vertical/Horizontal Autorange modes. General Autoset: Vertical – Horizontal – Trigger. Differential capture of the signals with banana leads with the MTX112, just like with a multimeter. Keyboard shortcuts The most frequently-used oscilloscope functions are assigned to keys on the PC keyboard. Remanent display. Double time base in real time. Multi-window display for simultaneously observing:
- The f(t) signal, its FFT and the table of automa- tic measurements.
- The f(t) signal of channels CH1 and CH2 with its XY representation, etc.
- The signal captured at a given moment and its evolution in real time Secure firmware releases The firmware upgrades are performed with the instrument in operation. This takes 3 minutes and the instrument automatically restarts with the new software version if the transfer has been comple- ted correctly, If not, the instrument restarts with the old software version. MTX112 10 MHz differential training oscilloscope (Didascope) HX0112 - Training kit Compact, economical and simple to use, the MTX112 and MTX162 screenless measuring instruments in the in@BOX range benefit from the same high performance and know-how as all Metrix® oscilloscopes. When connected to a PC, they take full advantage of all its useful features (large screen, unlimited storage capacity, etc.). oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr n Multiple functions: Oscilloscope, FFT Analyser and Recorder n Normal or remanent display (like on an analogue oscilloscope) n Deactivatable vertical and horizontal autorange functions to simplify operation n Communication: USB, Ethernet and Wifi (MTX 162UEW) n Automatic detection of the available instruments connected to the PC via USB or the Ethernet network Compact, economical and simple to use, this screenless measuring instrument in@BOX benefits from the same high performance and know- how as all Metrix® oscilloscopes. When connected to a PC, it takes advantage of all its useful features (large screen, unlimited storage capacity, etc.). MTX 162 Oscilloscope connected to a PC DIgITaL OSCILLOSCOPES References to order MTX162UE: MTX162 USB+Ethernet MTX162UEW: MTX162+WIFI Standard state at delivery
1 MTX 162 oscilloscope delivered with 2 x 100 MHz probes (HX0210), 1 standard
USB A/B cable, 1 removable mains power cable and a CD-Rom containing the PC software, the user manual in 5 languages, the programming guide and the drivers Available accessories See pages 107 to 115 Specifications MTX 162 Quick selection Bandwidth 60 MHz (bandwidth limiter: 15 MHz, 1.5 MHz or 5 kHz) Number of channels 2 channels, Class 1, common chassis-earths Sampling rate per channel Repetitive = 20 GS/s – One-shot = 50 MS/s Digital oscilloscope Vertical sensitivity 8 bits Sweep speed 32 calibres from 5 ns to 100 s/div Memory capacity Depth = 50,000 points Automatic measurements 19 measurements + Automatic phase On any type of curve – Markers and limits Triggering Mode Auto, Triggered, One-shot ROLL, auto level at 50% Sources CH1, CH2, mains Type Rising or falling edge, pretriggering adjustable from 0 to 100 % Digital recorder Recording duration 2 s to 33 minutes Acquisition mode Dedicated ROLL mode General specifications Screen commands "Windows-like" with online help – all commands accessible with mouse Communication USB type B and Ethernet RJ45 (10 Mb local or remote communication), Wifi (MTX 162UEW) Dimensions / Weight 270 x 213 x 63 mm / 1.8 kg Warranty 3 years / France For further details…
HX0112, DICABOX DIFF MTX Training module including exercises with mains power supply for MTX112U Standard state at delivery
1 MTX 112U, 1 mains lead, 2 sets of
Ø 4 mm leads with test probes,
1 USB A/B cable, CD-ROM
with SCOPEin@BOX LE and DIDASCOPEin@BOX software, 1 user manual in 5 languages, 1 programming manual in French and English + drivers Reference to order MTX112U: 1 oscilloscope with 2 x 10 MHz channels and USB Available accessories See pages 107 to 115 For further details… n Simplification of the connections with signal capture using banana leads, like on a multimeter n A Windows environment with quick display refresh in real time n Multi-windowed display to observe all the signals simultaneously n DIDASCOPEin@BOX simplified training software in addition to the complete SCOPEin@box LE software in a single software installation The MTX112U is the first screenless digital oscilloscope with 600 V CAT II differential inputs and also the easiest to use. This 10 MHz differential training oscilloscope is also an FFT analyser. MTX 112 DIDASCOPEin@BOX DIGITAL OSCILLOSCOPES Specifications MTX 112 Quick selection Bandwidth 10 MHz Number of channels 2 channels, Class 1, differential channels Maximum sampling rate Repetitive = 20 GS/s – One-shot = 50 MS/s (on each channel) Vertical resolution 8 bits Display mode 8 x 10 divisions - Multi-window (control panel, complete trace, zoomed trace, FFT, XY, measurements, etc.) Oscilloscope mode Vertical sensitivity 12 calibres from 20 mV to 100 V/div Sweep speed 29 calibres from 100 ns/div to 200 s/div Memory depth Acquisition depth = 50,000 points – "unlimited" storage capacity (PC storage capacity) Number of curves on screen 2 curves + 2 references Automatic measurements 19 time or level measurements and Phase measurement with SCOPEin@BOX LE and 5 time measurements with DIDASCOPEin@BOX Markers and Limits on all types of curves Other functions AUTOSET, +, -, x, /, cursors: dv, dt, 1/dt, phase - cursors linked to the trace or free FFT mode Analysis range 2.5 kpoints on 2 channels Trigger Modes Automatic, Triggered, One-shot and ROLL Sources CH1, CH2, mains (LINE) Type Rise and falling edge Coupling AC, DC Sensitivity 0.5 div, adjustment of trigger level ±8 div. Digital data storage File management Trace or text (compatible with Windows) for the signals and configuration in SCOPEin@BOX LE and text only with DIDASCOPEin@BOX Screenshot file (depending on Windows print manager configuration) GLITCH mode (transient capture) Detection and display of the Min & Max amplitudes between 2 samples - Event duration ≥ 20 ns Display modes Vector, Envelope, Averaging (factor 2,4 or 8) and Remanence XY mode CH2 versus CH1 General specifications PC screen commands 100 % of commands by mouse, "Windows-like menus" & online help – keyboard shortcuts Configuration memories "Unlimited", depends on PC configuration PC interfaces USB B connector – "Ready" LED on front panel - indication of front-panel test by PC Safety / EMC Safety as per IEC 61010-1 (2001) – 600 V CAT II – EMC as per EN 61326-1 Dimensions / Weight 270 x 213 x 63 mm / 1.8 kg Warranty 3 years oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr DIgITaL OSCILLOSCOPES MTX 1052 & MTX 1054 Versatile With 4 instruments in 1 for optimum efficiency (oscilloscope, real-time FFT analyser, harmonic analyser and logger), these high-performance oscil- loscopes are designed for laboratory applications in electronics, power electronics and electrical engineering. High-performance
- 2 or 4-channel oscilloscopes, 200 MHz.
- Quick acquisition mode and "SPO" Smart Persistence Oscilloscope display mode.
- Resolution doubled by the 9-bit converter.
- Vertical sensitivity from 250 μV/div to 100 V/div.
- Acquisition depth of 50,000 points per channel.
- Advanced trigger functions (pulse, delay, coun- ting, main/auxiliary channel, fault capture, etc.). Ergonomic
- Takes full advantage of the PC screen's size and high resolution
- Multi-windowing with trace, FFT, zoom and auto- matic measurements simultaneously
- "Windows" environment with familiar ergonomics
- Large storage capacity, direct use of files in Windows (Excel, Word, images, etc.), printing in Windows, etc
- ScopeNet web server on PC, tablet or Android smartphone. Communication experts
- Equipped with a USB link and Ethernet with inte- grated web server
- 100%-programmable using the SCPI standard, delivered with LabWindows and LabView drivers
- Products designed for integration in test benches (19" rack versions) LX 1600-PC logic analysis probe specially for BUS decoding!
- When the MTX 1052 and MTX 1054 oscilloscopes are used with the 16-channel logic analyser on PC (LX1600-PC), they allow decoding of a large number of buses: UART, I2C, SPI, CAN, LIN, Modbus, etc.
- Oscilloscope acquisition can be synchronized on the basis of the logic analyser trigger conditions. Oscilloscopes connected to a PC In addition to the same performance as traditional oscilloscopes, the SCOPEin@BOX models also of- fer the advantage of ergonomics as compact as their price! When connected to a PC, they make full use of all its performance features (large, unlimited storage capacity, etc.), while remaining easy to set up and use. Self-contained bus-decoding probe powered via USB
- RECSPO FFT 50 kpts
When used with the MTX 1032 double differential probes, they allow effective measurements in total safety on all the sub-assemblies not referenced to earth or possessing differentiated chassis-earths LX1600-PC: Logic Analysis probe, USB A/B cable, test cables and associated wire-grips, CD-Rom containing the SCOPEin@BOX-Logic Analysis PC software, usable only with a SCOPEin@ BOX Standard state at delivery
1 MTX, 1 mains cable, 2 voltage probes, 1 Ethernet crossover
cable, 1 Ethernet straight cable, 1 USB cable, 1 CD-Rom containing the SCOPEin@BOX PC software References to order MTX1052B-PC: MTX1052 2 x 150 MHz channels MTX1054B-PC: MTX1054 4 x 150 MHz channels MTX1052BW-PC: MTX1052B-PC, Wifi version MTX1054BW-PC: MTX1054B-PC,WiFi version MTX1052CW-PC: MTX 1052C, 2 x 200 MHz channels, Wifi version* MTX1054CW-PC: MTX 1054C, 4 x 200 MHz channels, Wifi version* MTX1052B-RK: MTX1052B-PC, RACK version MTX1054B-RK: MTX1054B-PC, RACK version Available accessories See pages 107 to 115 For further details… DIGITAL OSCILLOSCOPES Specifications MTX 1052 MTX 1054 Quick selection Bandwidth 150 MHz (Bandwidth limiter: 15 MHz, 1.5 MHz or 5 kHz) or 200 MHz Number of channels 2 channels, Class 1, common chassis-earths 4 channels, Class 1, common chassis-earths Sampling rate per channel Repetitive = 100 GS/s – One-shot = 200 MS/s (2 channels), 100 MS/s (4 channels) Vertical resolution 9 bits Display mode 8 x 10 div.- Multiple windows (control panel, trace, zoom, FFT, etc.) Probe factors Scaling of complete physical signal + choice of unit ("windows" virtual keyboard) Digital oscilloscope Vertical sensitivity 250 µV to 100 V/div Sweep speed 35 calibres from 1 ns to 200 s/div Data storage capacity Memory depth = 50,000 points – storage capacity depends on the configuration of the PC used Number of curves on screen 4 curves + 4 references Automatic measurements 19 measurements + automatic Phase –On all types of curves - Markers and limits Other functions FFT (calculated over 2,048 points), +, -, x, / - "Made-to-measure" function editor SPO (Smart Persistence Oscilloscope) Duration of persistence 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s and Infinite Display Monochrome or colour Performance Acquisition speed 50 kwaveforms/s/channel, No. of samples acquired: 19 MS/s/channel Harmonic analyser Analysis range Fundamental + 31 orders, on 1 to 4 channels and fundamental from 40 Hz to 1 kHz simultaneously Processing Permanent display: total RMS value & THD – Selected order: %F, phase, freq, Vrms Trigger Mode Auto, Triggered, One-shot Source CH1, CH2, EXT, Mains CH1, CH2, CH3, CH4, Mains Type Edge, pulse width or delay (40 ns-10.5 s), Counting (2-16,384 events), TV (525 = NTSC, 625 = PAL/SECAM), Adjustable pre-triggering from 0 to 100 %, Hold-off (40 ns-10.5 s) Coupling AC, DC, HFR (HF rejection), LFR (LF rejection) Sensitivity 0.6 div up to 10 MHz, 1.5 div from 10 MHz to 150 MHz (CH1, CH2, CH3 or CH4) Trigger level +/- 8 div. Digital recorder Sampling interval 40 μs to 53.57 s Recording duration 2 s to 31 days Acquisition mode Conditioned by thresholds on 4 channels Mode for capture of 100 faults in working memory Processing Time/date-stamped recordings, conversion and units of physical quantities, measurements by cursors and event search, file format compatible with standard spreadsheets (.txt) General specifications Screen commands "Windows-like" & online help – 100 % of commands with mouse Communication USB type B and Ethernet RJ45 (10 Mb local or remote communication), HTML server + Wifi, PC or Android tablet Dimensions / Weight 270 x 213 x 63 mm / 1.8 kg Warranty 3 years MTX rack version oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr aNaLOgUE OSCILLOSCOPES Specifications OX 530 OX 803B Quick selection Bandwidth 30/35 MHz 40 MHz Number of channels 2 Safety according to IEC 61010 Class 1 - 300 V CAT II Input sensitivity 5 mV to 20 V/div 1 mV to 20 V/div Operating modes CH1, CH2, ALT, CHOP auto, ADD, -CH2, XY CH1, CH2, ALT, CHOP, ADD, -CH2, XY, component test Time base 1 1 + delay Sweep speed 10 ns to 200 ms/div Triggering CH1, CH2, ALT, EXT, LINE AUTOTEST function SMART AUTOSET Special features Saving of settings, check on user choices by microprocessor, display of selections by LED Component tests Automatic and cursor measurements - - General specifications Digital link RS232 available as an option Power supply 94 - 264 V (48/440 Hz) Dimensions / Weight 435 x 330 x 163 mm / 5.5 kg 435 x 330 x 163 mm / 6.3 kg Accessories supplied 1 mains power lead, 1 user manual (S version with 2 probes also available) OX 530 n Simple and economical OX 803B n Comprehensive analogue instrument n Delayed time base and component tester With its coloured buttons and safety banana plugs, the OX 71 is the product of reference for training people how to use an oscilloscope. In terms of safety, their double isolation prevents risks due to connection errors: n 5 MHz bandwidth n 50 mV/div to 5 V/div sensitivity in 1-2-5 sequence n Sweep rate from 500 ns/div to 500 ms/div n AC, DC and earth coupling n IEC 61010-1 safety, class 2,
400 V CAT II
n Delivered with training software in 5 languages Analogue oscilloscopes remain ideal instruments for qualitative analysis and for viewing a signal's waveform as a function of time. These instruments are managed by a microprocessor and offer an AUTOSET automatic adjustment function as well as alternate triggering. OX 530 & OX 803B OX 71 Analogue oscilloscopes with cathode-ray tubes Isolated single-channel cathode-ray training oscilloscope References to order OX0530: OX 530 oscilloscope OX0530-S: OX0530 + 2 probes OX0803B: OX 803B oscilloscope OX0803BS: OX0803B + 2 probes OX71: single-channel 5 MHz training oscilloscope Standard state at delivery
1 OX, 1 mains power cable,
See pages 107 to 115 For further details…
OX 6000, DOX 2000 & DOX 3000 family Multi-purpose Expert Classic SPO Selection families Ox6202B Ox6062B OXI6204 DOX2025 DOX2040 DOX2100 DOX3104 DOX3304 Bandwidth 60 to 200 MHz 200 MHz 40 to 100 MHz 100 and 300 MHz Channels (number/type) 2 / class 1 Metal BNC 4 / isolated Plastic BNC 2 / class 1 Metal BNC 4/class 1 Metal BNC IEC61010 safety 300 V CAT II 600 V CAT II 300 V CAT II 300 V CAT I One-shot digital sampling 1 GS/s 2.5 GS/s 500 MS/s to 1 GS/s 2 GS/s Repetitive mode 50 GS/s 100 GS/s 10 to 50 GS/s Vertical resolution 10 bits 12 bits 8 bits 8 bits PC communication via USB / Ethernet •/• •/• •/- •/• "Oscilloscope" specifications Max. input sensitivity 2.5 mV/div 2.5 mV/div 2 mV/div 2 mV/div Max. input amplitude 100 V/div 200 V/div 10 V/div 10 V/div Time base (per division) 1 ns-200 s 1 ns-200 s 2.5 ns-50 s 1 ns - 50 s Memory depth Acquisition memory 2.5 or 50 k / channel Up to 2 GB on SD Card 50 kpts / channel Up to 2 GB on SD Card 40 kB / channel Up to 2 MB 28 Mpts Automatic measurements/Cursors 20/• 20/• 32/• 32/• Other functions FFT Lin & Log spectral analysis 10 bits / 60dB 12bits / 60dB 8 bits 8 bits TRMS multimeters / Generator 200 kHz 200 kHz 25 MHz generator Harmonic analyser 61 orders 61 orders - Threshold recorders (number of channels) 2 4 Recorder Power/power harmonics measurement • • - General specifications LCD colour screen 5.7 inches 5.7 inches 7 inches 8 inches Software calibration 100% "casing closed" • • ScopeNet PC web server/ANDROID app. •/• •/• Pages 58-59 58-59 60-61 62-63 LaBORaTORY DIgITaL OSCILLOSCOPES Selection guide oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr n Backlit ¼ VGA colour TFT LCD TOUCH screen n Multi-interface communication: RS232, USB, Centronics and Ethernet n High-capacity data storage on removable SD-Card up to 2 GB and more capacity on FTP server n WEB server for "100 % of functions", FTP server/client for easy file exchange and Instruments Administrator via Ethernet on PC or Android tablet The OXi 6204 proposes all the functions of a 4-channel SCOPIX with 4 x 600 V CAT II plastic BNC terminals and 1 x RJ45 cable for Ethernet connection. 4 modes in one instrument: oscilloscope + multimeter + recorder + analyser. OX 6062B, OX 6202B & OXi 6204 General-purpose digital oscilloscopes Extension of storage capacity As these instruments are equipped with micro SD cards, users can store all the data (refe- rence curves, instrument settings, screenshots) up to 2 GB. The USB/SD card reader delivered with the instrument makes data transfer onto PC quick and simple. References to order OX6062B-CSD: Digital oscilloscope, 2 x 60 MHz, SD, colour OX6062B-MSD: Digital oscilloscope, 2 x 60 MHz, SD, B&W OX6062B-CSDO: Digital oscilloscope, 2 x 60 MHz, SD, colour with all options installed OX6062B-CFG: Digital oscilloscope, 2 x 60 MHz, SD, colour, with one extra configurable option as selected OX6202B-CSD: Digital oscilloscope, 2 x 200 MHz, SD, colour OX6202B-CSDO: Digital oscilloscope, 2 x 200 MHz, SD, colour with all options installed OX6202B-CFG: Digital oscilloscope, 2 x 200 MHz, SD, with one extra configurable option as selected OXi6204: Digital oscilloscope, 4 x 200 MHz, SD, colour plus recorder and 50 kpts options installed OX6000B accessories HX0003: 1/10 safety probe, 150 MHz, 400 V HX0004: 1/10 safety probe, 250 MHz, 1,000 V HX0210: 1/1 standard probe, 100 MHz, 300 V CAT II HX0220: 1/1 standard probe, 200 MHz, 300 V CAT II HX0077: 50 kpts memory option HX0028: Harmonic analyser mode HX0029: Recorder mode OXi6204 accessories HX0108: 600 V safety probe + 600 V BAN/BNC adapter HX0106: BNC-BNC lead 1 m 600 V (x2) HX0107: BNC-BAN adapters 4 mm 600 V (x2) Standard state at delivery
1 OX 6000 oscilloscope , 1 stylus, 1 user manual and 1
programming manual on CD-Rom, 1 μSD card with a minimum capacity of 1 GB plus SD adapter, 2 x 1/10 probes, 1 Ethernet crossover cable and 1 USB / RS232 cable Available accessories See pages 107 to 115
- REC FFT 2.5 kpts 50 kpts DMM DIgITaL OSCILLOSCOPES
For further details… Specifications OX 6062B OX 6202B OXi 6204 Human-Machine Interface Display Colour 1/4 VGA LCD (115 x 86 mm) - 320 x 240 – TFT backlighting (adjustable automatic power off) On-screen display of curves 2/4 curves + 4 references Commands 32 commands in direct access & shortcuts – 1 on-off and standby button Touch screen – "Windows-like" menus and graphical commands 5 complete languages with menus & online help (English, French, Italian, Spanish and German) Vertical Bandwidth 60 MHz 200 MHz 15 MHz, 1.5 MHz or 5 kHz bandwidth limiter Number of channels 2 Class 1 channels (referenced to earth) 4 isolated channels
300 V CAT II - Metal BNC 600 V CAT II - Plastic BNC
Vertical sensitivity Ranges from 2.5 mV to 100 V/div (± 2 %) 200 V/div Vertical zoom "One Click Winzoom" system (graphical zoom directly on screen) – x 16 max. Probe factors 1 / 10 / 100 / 1,000 or any scaling – definition of measurement unit Horizontal Sweep speed 35 calibres from 1 ns/div to 200 s/div.- Roll mode from 100 ms to 200 s/div Horizontal zoom "One Click Winzoom" system (graphical zoom directly on screen) - x 5 max. Triggering Mode Automatic, Triggered, One-shot, Auto Level 50 % / CH1, CH2, EXT, LINE Edge, Pulse width (20 ns - 20 s), Delay (120 ns to 20 s), Counting, TV frame or TV line (525 = NTSC or 625 = PAL/SECAM) Continuous adjustment of Trigger position Digital memory Maximum sampling rate 50 GS/s in ETS mode 100 GS/s in ETS mode 1 GS/s in one-shot mode (on each channel) 2.5 GS/s in one-shot mode Storage capacity: 2,500 pts per channel (200 curves in memory) or 50 kpts 50 kpts
2 GB on SD card - 2 ns GLITCH mode / Envelope, Averaging (factors 2 to 64) / XY mode
AUTOSET Complete in less than 5 s, with recognition of the channels – Frequency > 30 Hz FFT (Lin or Log) with measurement cursors - Functions: + , - , x , / with management of coefficients & units Measurements: 2 or 3 cursors & 20 automatic measurements – Resolution 10/12 bits, 4-digit display Multimeter Channels / counts 2 channels / 4,000 cts 4 channels / 8,000 cts Min/max bargraph – TRMS Time/date-stamped graphical recording (5 min to 31 days) AC, DC, AC + DC voltages 300 to 300 Vrms or 400 Vdc 300 mV to 600 Vrms or 600 Vdc V dc accuracy 0.5 %R +5 D – bandwidth 200 kHz Resistance 80 Ω to 32 MΩ – accuracy 0.5 %R + 5 D – quick continuity test < 10 ms Other measurements Capacitance: 5 nF to 5 mF / Frequency: 200 kHz / 3.3 V diode test Harmonic analyser mode (option) 2/4 multi-channel analysis, 61 orders, fundamental frequency from 40 to 450 Hz in auto or manual mode Simultaneous measurements: total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms) Recorder mode (option) Integrated Duration / Sampling from 2 s to 1 month / 800 μs to 18 min. (40 μs to 53 s with "Extended Memory" option, recording conditions on thresholds or window, simultaneous conditions on several channels, with adjustable duration from 160 μs, analysis of recordings, scale and physical units, automatic or cursor measurements, time/date-stamped fault search function, zoom, etc. General specifications Network screen printing (standard), 11 B&W or colour drivers: IBM Proprinter, Epson ESC/P, Canon HP PCL, Seiko DPU411, RS232 (standard) or Centronics Postscript Image files: ".bmp" approx. 10 kB, ".gif" approx. 5 kB (optional accessory) (storage in memory, RS232 or Ethernet transfer) PC communication Local Ethernet, RS 232 (max. 115 kbs) or USB (option) Remote Ethernet 10 Mb and ScopeNet web server "SX-Metro" PC application software (option) Mains power supply Adjustable standby mode Multi-voltage: 98-264 V / 47-63 Hz / < 15 W - Removable cable Mechanical specifications 230 (h) x 185 (l) x 180 (w) mm / 2.1 kg Warranty Lifetime warranty DIGITAL OSCILLOSCOPES Communication with ANDROID tablets or smartphones oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr BENCHTOP DIgITaL OSCILLOSCOPES Exceptional ergonomics: extra-bright 7" TFT colour screen
- Customization of the display to suit your needs: normal or persistent display, YT or XY format, screen types with adjustable colours, graticule, brightness, contrast, etc.
- Simple front panel: traditional front-panel controls (rotary knobs and keys)
- 5 language choices selectable per menu (English, French, Spanish, Italian, German)
- Quick power-up and power-down in less than 10 s
- Easy to transport due to its shape, its built-in handle and its 9-inch depth High performance and multiple acquisition and analysis functions
- Maximum sampling rate of up to 1 GS/s in one- shot mode and 50 GS/s for periodic signals
- Acquisition memory depth from 32 kpoints to
2 Mpoints, depending on the model, to optimize
- 5 complete trigger types: edge, pulse, video, slope and alternate
- 32 simultaneous automatic measurements on screen and manual cursor measurements
- Recording of up to 6 Mpoints by slow acquisition Practical interfaces and printing
- Usual communication: USB host and device (PC, Pictbridge printer, USB key)
- Multiple storage: 20 configurations and 5 types of recordings: parameters, curves, images, .csv and factory settings internally or on USB key, etc.
- Comprehensive EASYSCOPE software for all your analyses 2-channel colour digital oscilloscopes DOX 2000 family Simple MATH functions +/-/*/ and "real-time" FFT function with simultaneous display of trace Easyscope software for data processing (csv), SCPI command transmis- sion, screenshots (bmp), configuration, virtual control panel
- RECFFT 2 MptsMath
Standard state at delivery
1 DOX digital analyser-oscilloscope,
European mains power cable, 2 x 1/1 and 1/10 switchable voltage probes, USB A/B cable, CD-ROM containing PC software and user manual Demonstration board available for practical exercises: HX0074 References to order DOX2025: Digital oscilloscope 2 x 25 MHz DOX2040: Digital oscilloscope 2 x 40 MHz DOX2100: Digital oscilloscope 2 x 100 MHz Available accessories See pages 107 to 115 For further details… BEnCHTOP DIGITAL OSCILLOSCOPES Specifications DOX 2025 DOX 2040 / DOX 2100 Human-Machine Interface Type of display 7" colour TFT LCD screen (resolution 480 x 234) / Adjustable brightness and contrast Display of curves on screen 8 x 18 division trace area / 2 curves + reference + Math function - Complete graticule or borders Display mode: Samples or Vectors with interpolation or Persistence Mode Commands Usual direct commands via buttons on front panel / System with menus on right-hand side of screen with selection using 5 buttons opposite – "Menus On/Off" and print commands Choice of language By menu, 5 languages (FR/EN/DE/IT/ES), online help in English Vertical deflection Bandwidth 25 MHz 40 MHz / 100 MHz
20 MHz bandwidth limiter
Number of channels 2 channels, common chassis-earths Impedance 1 MΩ / 18 pF and External Trig channel Display of traces Channel number, earth reference indicator and trace in the colour of the channel Maximum input voltage ± 300 Vp-p (without probe) Vertical sensitivity 12 calibres from 2 mV to 10 V/div - Basic accuracy ±3 % Rise time < 14 ns < 8 ns (DOX2040) <3.5 ns (DOX2100) Compensated probe factors 1 / 5 / 10 / 50 / 100 / 500 / 1,000 Horizontal deflection Scan or ROLL mode 100 ms/div. to 50 s/div. (Recorder - Scan mode) Horizontal zoom Yes Triggering Sources / Modes CH1, CH2, Ext, Ext/5, mains / Automatic, Triggered, One-shot- XY Roll mode 100 ms/div. to 50 s/div. Type Edge, pulse width (20 ns - 10 s), video (Pal, Secam, NTSC), slope, alternate Coupling AC, DC, HFR (HF rejection), LFR (LF rejection) Digital data storage Maximum sampling rate One-shot = 250 MS/s (2 channels), 500 MS/s (1 channel) Repetitive = 10 GS/s One-shot = 500 MS/s (2 channels), 1 GS/s (1 channel) Repetitive = 50 GS/s Vertical resolution 8 bits (vertical resolution 0.4%) Memory depth Max. depth = 32 kpoints "Unlimited" storage capacity (USB key) Max. depth = 2 Mpoints (long MEM) "Unlimited" storage capacity (USB key) User memory 2 MB for storing trace, text and configuration files, math functions, print files, image files, etc. File management Trace files (proprietary format and .CSV format compatible with spreadsheets for the signals / Complete instrument setup files / Screenshot files (.BMP format compatible with Windows) PEAK DETECT mode (transient capture) Minimum event duration = 10 ns Display modes Points or vectors Persistence (1s, 2s, 5s, 10s.20s or infinite) or Averaging (factor from 4 to 256) XY mode Yes Other functions AUTOSET AUTO-adjustment of amplitude, time base and trigger position MATH functions on the channels Trace calculated in "real time": CH1 and CH2: addition, subtraction, multiplication, division FFT analyser FFT calculated over 1,024 points / Simultaneous display of trace + FFT / 4 window types (Rectangle, Hamming, Hanning, Blackmann) Manual measurement cursors Manual, tracking and automatic modes PASS/FAIL Pass/Fail test on the basis of a limit envelope Recorder Recording mode for slow signals > 100 ms (6 Mpoint ROLL) Automatic measurements 32 time or level measurements Probe calibration signal Yes Warranty 3 years oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr SPO BENCHTOP DIgITaL OSCILLOSCOPES DOX 3000 family Comprehensive with high performance 100 and 300 MHz bandwidth with built-in 25 MHz generator and serial bus decoding 4-channel oscilloscopes with TFT screen 8 inches wide offering 256 levels of colour intensity. Display using Sensitive Phosphor Oscilloscope technology for optimized waveform capture: 110,000 wfs/s, exceptional acquisition and display functions for precisely reconstructing a signal. Maximum acquisition memory depth: 28 Mpoints. Practical, intuitive HMI with tradition front- panel commands (rotary knobs with lighting), 5 languages selectable by menu (English, French, Spanish, Italian and German) plus help in French and English. High-performance oscilloscope with maximum sampling rate of up to 2 GS/s in real time, vertical sensitivity from 2 mV/div. to 10 V/div. and from 1 ns to 50 s/div with complex and complete triggers (Pattern, windows, interval, Dropout, runt). A built-in 25 MHz arbitrary signal generator with programming software is included. Serial bus decoding function with integrated triggers: I2C, SPI, UART, CAN, LIN and MSO 8-channel digital logic analyser for analysing digital transmissions (DOX-MSO3LA option). Easy analysis with 32 automatic measurements and statistical chart, manual cursor measurements and advanced math functions: simultaneous display of trace + 4-channel FFT. Communication: USB host, USB key and device (PC, Pictbridge printers) and Ethernet. FFT28 Mpts Math
For further details… Standard state at delivery
1 DOX digital oscilloscope, European
mains power cable, 4 x 1/10 voltage probes, 1 USB cable, USB key containing software, user manual and practical training exercises Demonstration board available for practical exercises: HX0074 References to order DOX3304 (300 MHz, 4 channels) + arbitrary generator+ serial bus decoding DOX3104 (100 MHz, 4 channels) + arbitrary generator + serial bus decoding DOX-MSO3LA: MSO 8-channel logic probe Available accessories See pages 107 to 115 sPO BEnCHTOP DIGITAL OSCILLOSCOPES Specifications DOX 3104 DOX 3304 Interface Screen Colour 8" TFT LCD screen, 800 x 480 pixels, 24 bits On-screen display On 8x14 div with 4 channels + reference + Math functions and statistics table – full screen Vector or point modes with interpolation, permanent SPO mode: normal or colour Language French, English, Italian, Spanish and German Vertical deflection Bandwidth 100 MHz / 300 MHz - Bandwidth limiter: 20 MHz No. of channels 4 channels + 1 external channel Max. input voltage 300 V (DC+AC Pk) Vertical sensitivity 12 calibres from 2 mV to 10 V/div – Accuracy ±3% – 8-bit resolution Rise time < 3.5 ns (DOX 3104) / < 1.2 ns (DOX 3304) Probe compensation factors x 0.1 / 0.2 / 0.5 / 1 / 5 / 10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 Horizontal deflection Time base speed 1 ns/div to 50s/div (oscilloscope) Max. no. of traces captured per second 110,000 traces/s Horizontal zoom Compression, expansion Automatic ROLL mode 100 ms/div to 50 s/div (1-2-5 step) Trigger system Sources/Mode CH1, CH2 or CH3, CH4 Ext, Ext/5, AC line / Auto, Normal triggered, One-shot Type Edge, Pulse (20 ns to 10 s), Slope (rising, falling), Video (NTSC, PAL, SECAM), Windows, Interval, Dropout, Runt, Pattern Trigger on serial bus and Decoding I2C, SPI, UART/RS232, CAN, LIN MSO logic analyser input Option: 8 channels + clock for TTL/CMOS/LVCOM/CUSTOM signals Acquisition Real-time sampling rate ETS: 2 GS/s Vertical resolution 8 bits (vertical resolution 0.4%) Acquisition depth Up to 28 M: 14 Mpts per channel, adjustable: 7 k / 14 k / 70 k / 140 k / 700 k / 1.4 M / 7 Mpts File manager Trace files (DAV proprietary format and Excel-compatible ".CSV" format) ".set" configuration files – ".bmp" screenshot files Acquisition Normal, Peak detect, Average, High res. Peak detection Minimum event duration = 10 ns "Statistics" mode Measurement of events Other functions AUTOSET AUTO adjustment: amplitude, time base and trigger MATH function Trace calculated in real time: CH1, CH2, CH3, CH4, + , - , x , / , (d/dt), integral (∫dt) and square root (√). FFT analyser FFT calculated on 1,024 points - simultaneously with the waveform for the 4 channels Adjustable windowing: rectangular, Hamming, Hanning, Blackmann Cursors Manual, Track mode and Auto PASS/FAIL Pass/Fail mode with specific terminal for envelope adjustment Automatic measurements 32 measurements and statistics table Built-in 25 MHz function generator 25 MHz- 125 MS/s - 14 bits - arbitrary function generation with EasyWave General specifications Recording Internal storage or USB flash drive on front panel Printing Via USB Host (PictBridge) Communication on PC Via USB device or Ethernet link for EASYSCOPE (OX) and EASYWAVE (GX) software Power supply Universal 100-240 V / 45-440 Hz/ 50 VAmax with removable cable Safety / EMC / Locking Compliant with the IEC 6101-1 standard, 300V CAT I - EMC as per EN61326-1 - Kensington lock Temperature Use: 0°C to +40°C - Storage: -20°C to +60°C Mechanical specifications 352 x 111 x 224 mm – 3.6 kg (4 channels) – IP20 3-year warranty oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr SOFTWARE FOR THE DOX FAMILY OF BENCHTOP OSCILLOSCOPES EASYSCOPEX is the PC data processing software for the oscilloscopes in the DOX family. It can be used to extend the oscilloscope's functions via USB (without drivers) or Ethernet (DOX 3000), depending on the models, for:
- Recovery of the .csv trace files
- Transmission of programming commands (SCPI format)
- Remote command test via VIRTUAL PANEL
- Recovery of screenshots in .bmp format EASYWAVE is PC software which allows users to:
- Recover the curves from the oscilloscope mode and then modify the waveforms using drawing tools
- Transfer or import waveforms into the ARBitrary function (4 memory locations)
- Consult the file library (sine, square, ramp, pulse, noise, cardiac, exponential, etc.) in the memory of the oscilloscope's generator mode These software products are available from the DOX Support section on our website. ON-SITE DIgITaL OSCILLOSCOPES Recovery of traces Screenshots Transmission of SCPI commands Virtual panel Creation of waveforms Available at the rear of the instrument: n Input channel for the Pass/Fail mask test, ideal for quickly identifying problems on a signal n Input channel for external triggering n PC/device communication interfaces: USB or Ethernet n Slot for KENSINGTON lock for greater security
On-sITE DIGITAL OSCILLOSCOPES "Stand-alone" multi-function oscilloscopes Handscope Scopix Maintenance Electronics Energy Industrial Fieldbus Selection families OX5022 OX5042 OX7202-OX7204 OX7102-OX7104 OX7062 OX7104P OX7042P OX7042 OX7202 BUS OX7204 BUS Bandwidth 20 and 40 MHZ 60 to 200 MHz 40 to 100 MHz 40 MHz 200 MHz Channels (number/type) 2 isolated 2 or 4 / isolated 2 or 4 / isolated 2 / isolated 2 or 4 / isolated IEC61010 safety 1000 V CAT II / 600 V CAT III One-shot digital sampling 50 MS/s 2.5 GS/s 2.5 GS/s 2.5 GS/s 2.5 GS/s Repetitive mode 2 GS/s 50 or 100 GS/s 50 or 100 GS/s 50 or 100 GS/s 50 GS/s Vertical resolution 9 bits 12 bits 12 bits 12 bits 12 bits Transient detection (Glitch) > 20 ns 2 ns 2 ns 2 ns 2 ns PC communication / Ethernet • •/• •/• •/• •/• Ethernet 10Mb + Web server • • • • Alimentation secteur / Batterie •/• •/• •/• •/• •/• "Oscilloscope" specifications Max. input sensitivity 5 mVdiv 156 μV/div 156 μV/div 156 μV/div 156 μV/div Max. input amplitude 200 V/div 200 V/div 200 V/div 200 V/div 200 V/div Analogue filter 1.5 MHz, 5 kHz 15 MHz, 1.5 MHz, 5 kHz 15 MHz, 1.5 MHz, 5 kHz 15 MHz, 1.5 MHz, 5 kHz 15 MHz, 1.5 MHz, 5 kHz Time base (per division) 25 ns-200 s 1 ns-200 s 1 ns-200 s 1 ns-200 s 1 ns-200 s "Memory depth 2.5 k / channel 2.5 to 50 k / channel 2.5 to 50 k / channel 2.5 to 50 k / channel 50 k / channel Acquisition memory" 2 MB memory Up to 2 GB on SD card Up to 2 GB on SD card Up to 2 GB on SD card Up to 2 GB on SD card No. of reference or math curves on screen Envelope / Averaging modes SPO (Smart Persistence Oscilloscope) Automatic measurements / Cursors Pulse trigger width/number - • • • • Video trigger (line counter) - • • • • Trigger on measurement & automatic backup - •/• •/• •/• •/• Advanced + - / x / : / calculation functions • • • • • Autoset with channel selection • • • • • Other functions FFT Lin & Log spectral analysis - 12 bits / 72 dB 12 bits / 72 dB 12 bits / 72 dB 12 bits / 72 dB TRMS multimeters 50 kHz 200 kHz 200 kHz 200 kHz 200 kHz Harmonic analysis 31 orders 61 orders 61 orders 61 orders Threshold recorders (no. of channels) 2 2 or 4 2 or 4 2 2 or 4 Power/Power Harmonics measurement • • • • General specifications Colour LCD / B&W / Tube screen •/-/- •/-/- •/-/- •/•/- •/•/- 100% "casing closed" software calibration • • • • • ScopeNet PC web server / ANDROID app •/• •/• •/• •except bus /• Pages 66-67 68-69-71 68 to 70 68-70 72 Selection guide oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr The most compact oscilloscopes with totally isolated channels on the market for all your work on electrical installations in the field as well as for general maintenance. OSCILLOSCOPES WITH ISOLaTED CHaNNELS www.handscope.chauvin-arnoux.com OX 5022 & OX 5042 Stand-alone portable digital oscilloscopes W 2.5 kptsDMM n 4 tools in 1 in addition to the Oscilloscope function: 2 multimeter (8,000 counts) and recorder channels: + Harmonic analyser: on fundamentals from 40 Hz to 450 Hz + Power measurement As well as math functions and simple triggers with automatic scaling. n 3.5" colour TFT screen with LED backlighting and 320 x 240 resolution n Simple to use: one key equals one function (triggering, configuration, etc.) n Integrated interactive multilingual help function n Recording of the measurements n Isolated USB communication using the SCPI protocol The HANDSCOPEs are ideal for maintenance and troubleshooting in the field, technical education, etc. There are a large number of possible applications: measurements on 2 signals with different earths, power measurements on variable speed drives with display of the waveform, analysis of the mains outage time (equipment operating on battery), etc.). It is possible to store the graphs, data points and screenshots to help you produce your reports. And the HANDSCOPEs are delivered with probes and and a banana adapter for measurements up to 600 V. A version specially designed for education (-KE) is delivered with 2 banana-socket inputs to simplify your connections for practical exercises in total safety. The SX METRO software is an additional post-processing tool for processing your data: min./max., remanence when testing, FFT, math, filter, decoding and power functions, etc. The 20 and 40 MHz HANDSCOPE models are compact, simple and effective tools for your troubleshooting, with 2 totally-isolated channels to measure all industrial signals. Ergonomics Icons help you understand the measurements
Applications
For further details… OSCILLOSCOPES WITH IsOLATED CHAnnELs Specifications OX 5022 OX 5042 Quick selection Bandwidth 20 MHz 40 MHz Bandwidth limiter 1.5 MHz, 5 kHz Number of channels 2 totally-isolated channels IEC 61010 safety 600 V CAT III Maximum sampling rate 2 GS/s in ETS mode – 50 MS/s in one-shot mode on each channel Vertical resolution 9 bits Display mode 2,500 real acquisition points on screen Envelope, Averaging (factors 2 to 64) and XY (vector) Digital oscilloscope Vertical sensitivity 5 mV to 200 V/div Sweep speed 25 ns/div to 200 s/div –Roll Mode from 100 ms to 200 s/div Data storage Memory depth: 2,500 points per channel 2 MB for storing files: trace (.trc), text, (.txt), configuration (.cfg) and image files (.bmp) Display of curves on screen 2 curves + 2 references + memory trace or mathematical calculation Automatic measurements 18 time or level measurements and phase measurement 2 cursors: V, T, dV, dt simultaneously –4-digit display resolution Triggering Automatic, triggered, one-shot & triggered Roll on Edge or Pulse Width (20 ns – 20 s) TRMS multimeter Specifications 2 channels, 8,000-count display + min/max bargraph Recording Graphic recording of 2,700 measurements (5 min to 1 month) Measurement functions AC, DC and AC+DC voltages, resistance, continuity, capacitance, frequency, rotation speed,
3.3 V diode test, temperature measurement (with K thermocouple or infrared probe)
Power Single-phase and balanced three-phase active power values (with or without neutral), simultaneous display of current Harmonic analyser Multi-channel analysis 2 channels, 31 orders, fundamental frequency from 40 to 450 Hz Simultaneous measurements Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms) General specifications PC communication Isolated optical USB interface –"SX-Metro" PC application software supplied Power supply 6 x LR6 batteries or 6 AA NiMh batteries – Battery life up to 8 hrs 30 min Universal mains adapter isolated from the channels – Quick charging in 3 hours Mechanical specifications 214 x 110 x 57 mm – 1.2 kg with batteries moulded elastomer casing, IP54 protection Warranty 3 years Accessories and replacement parts Standard state at delivery Version C: 1 oscilloscope delivered with 1 x 1/10 600 V probe,
1 BNC/Banana adapter, 1 set of banana leads, 1 mains adapter,
1 set of 6 x AA NiMh batteries, 1 hands-free bag, 1 CD-Rom containing 1 user manual and 1 programming manual. Version CK: 1 oscilloscope delivered with 1 x 1/10 600 V probe,
1 BNC/Banana adapter, 1 set of banana leads, 1 isolated optical
USB communication cable, 1 mains adapter, 1 set of 6 x AA NiMh batteries, 1 hands-free bag, 1 CD-Rom containing 1 user manual, 1 programming manual, the drivers for the optical USB cables and the SX-Metro PC software. References to order OX5022-C: 1 oscilloscope 2 x 20 MHz OX5022-CK: 1 oscilloscope 2 x 20 MHz + USB communication OX5042-C: 1 oscilloscope 2 x 420 MHz OX5042-CK: 1 oscilloscope 2 x 40 MHz + USB communication Available accessories See pages 107 to 115 Software: page 76 oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr OSCILLOSCOPES WITH ISOLaTED CHaNNELS The Ethernet interface and SCOPENET can be used with a PC to control and view all the SCOPIX models by means of their IP address and a simple browser. An ANDROID applica- tion for tablets and smartphones can also be downloaded from Google PLAY. 6 modes to cover all the domains from 40 to 200 MHz The Scopix range Performance n 5 instruments in 1! All the Scopix models are simultaneously oscilloscopes, multimeters, FFT analysers, harmonic analysers and loggers n Bandwidth from 40 to 200 MHz n 2 or 4 isolated channels Ergonomics n Monochrome LCD or colour TFT touch screen with LED backlighting n Traditional control interface: 33 direct command keys n Control by "Windows-like" menus or graphical objects on the touch screen. The familiar "Windows-like' environment is simple to learn and use. On the touch screen, users can access all the functions with the stylus via the drop-down menus and can act on the graphical elements (cursors, triggers, etc.). The PROBIX® "Plug & Play" system for safe, simple use n Automatic recognition of the sensor type and the associated measurement n Accessories powered by the instrument n Automatic scaling and measurement units Universal communication n Multiple interfaces: RS232, USB, Ethernet n Removable microSD card for large- capacity data storage and transfer n ScopeNet with cursors and automatic measurements n FTP server/client and Instrument Administrator on Ethernet The extensive functions of the SCOPIX family make it ideal for the requirements in several sectors of activity: n In the industrial maintenance sector, the OX 7042 and OX 7104 are designed for maintenance technicians (see details of functions on page 70) n In the Energy sector, the OX 7042P and OX 7104P are available in "Power" versions with special accessories and application modules n In Electronics, the OX 7062, OX 7102, OX 7104, OX 7202 and OX 7204 have all the features necessary to meet the needs of technicians and engineers involved in the design, commissioning or maintenance of equipment (see details of functions on page 71) W• REC FFT 50 kptsDMM
www.chauvin-arnoux.com/scopix OSCILLOSCOPES WITH IsOLATED CHAnnELs Specifications OX 7042 OX 7062 OX 7102 OX 7104 OX 7202 OX 7204 Quick selection Bandwidth 40 MHz 60 MHz 100 MHz 100 MHz 200 MHz 200 MHz
15 MHz, 1,5 MHz and 5 kHz bandwidth limiter filters
Number and type of channels 2 isolated channels 4 isolated channels 2 isolated channels 4 isolated channels IEC 61010 safety 600 V CAT III Sampling rate per channel 2.5 GS/s in one-shot mode, 100 GS/s for periodic signals Transient detection "Glitch" capture, minimum duration 2 ns Vertical resolution 12 bits, giving a vertical resolution of 0.025 % Display modes Vector, interpolation, persistence, envelope, averaging (factors 2 to 64) Scaling and physical units Definition of any factor and the corresponding unit Digital oscilloscope Input sensitivity 2.5 mV to 200 V/div (156 μV max. with zoom thanks to the 12-bit resolution) Time base 1 ns to 200 s/div, Roll mode from 100 ms to 200 s/div Data storage Several tens of thousands of 2,500-point curves (in universal "text" format) Memory depth up to 50 k – Mass storage on removable SD card up to 2 GB Reference curves on screen 1 per active channel (1 to 4) / Direct storage with dedicated key Automatic measurements with marker 20 simultaneous measurements on curves or deviations from the reference curve – 12-bit resolution Triggering Edge, pulse width, delay, counting, video with line counter and on one of the 20 automatic measurements Calculation functions on channels FFT on 2,048 points, +, -, x, /, and complex function generator TRMS multimeter (AC, AC+DC) Measurement channels with 200 kHz bandwidth 2 isolated channels 4 isolated channels 2 isolated channels 4 isolated channels Measurement functions Voltage, current, frequency, capacitance, temperature (Pt 100, K TC), diode test and audible continuity test, relative mode, min/max mode Graph of measurements with cursors Duration from 5 min to 31 days, data storage in "universal text" format Triggering on threshold checks Harmonic analyser* Multi-channel analysis (2 or 4 depending on model) 61 orders, fundamental frequency from 40 Hz to 450 Hz Simultaneous measurements Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms) 12-bit digital recorder* Multi-channel recording Duration from 2 s to 31 days, normal mode or automatic fault capture mode with pre-trigger Sampling interval from 40 μs (50 k memory) Recording conditions On thresholds or windows, simultaneous conditions on several channels Recording (50,000 points) on the PC hard disk or SD card Analysis of recordings Scale and physical units, measurement by cursors, fault detection, zoom, etc. Power measurement* Measurement functions Active, reactive and apparent power, on single-phase or three-phase, and PF Harmonics Harmonic analysis on apparent power General specifications "Windows-like" operator interface B&W or colour* Colour Simultaneous display of traces Up to 4 traces + 4 references on screen / "Full screen" trace mode PC communication and printing RS232*, isolated USB* or Ethernet 10 Mb / Network or Centronics* printers FTP mode to use the PC hard disk as a storage unit Virtual Printer server LPD for printing on a printer connected to a PC Web server with real-time display, remote control and automatic measurements Power supply by rechargeable battery Battery life up to 8 hrs, quick charging in 2 hrs without removing the batteries * Depending on models or option OSCILLOSCOPES WITH ISOLaTED CHaNNELS SCOPIX III, the multi-function portable oscilloscopes which are also measurement experts oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr OSCILLOSCOPES WITH ISOLaTED CHaNNELS OX 7042 & OX 7104 Scopix Industrial Maintenance 2 models equipped with a broad range of functions for acquiring and recording anomalies n Bandwidth: 40 or 100 MHz n 2 or 4 isolated channels, 600 V Cat III safety (1,000 V with the HX0030B probe or the HX0095 adapter) n Colour or monochrome screen For the Oscilloscope, Recorder and Multimeter modes, it is possible to capture faults by setting a software trigger based on monitoring of the tolerance interval qualified by a duration. Oscilloscope mode: capture on automatic measurements Users have access to 20 automatic measure ments in this mode. Once the required mea- surements have been selected, all you have to do is set the trigger thresholds and activate fault capture. Mains monitoring or surveillance mode on up to 4 channels in multi- meter mode If the RMS value of the signal reaches the min or max levels, defined on each channel, the event is recorded and dated in a list of faults; this list can be saved in a file. Recorder mode: fault capture To monitor the variations of physical or mechanical phenomena over time, there is a software module available to inte grate a genuine fast digital recorder into the instrument. It offers acquisition intervals as short as 40 μs between 2 measurements and the recordings may cover any period from 2 seconds to one month. Automatic fault capture can be perfor med by monitoring 1 or 2 thresholds per channel. The fault duration can be set from 160 μs to approximately 8 days. This type of monitoring can also be performed on tolerance windows. Capture triggers storage of the phenomenon observed in non-volatile memory (up to 50 kpoints) or automatic acquisition of successive time/date-stamped faults (max. 500 faults). The faults recorded automatical ly are stored either in the instrument's internal memory or on an FTP server (PC hard disk). Harmonic Analyser mode Harmonic analysis is performed up to the 61st order (THD on a minimum of 50 orders), with a fundamental frequency between 40 and 450 Hz. It is possible to preselect the frequency of the fundamen tal for the standards (50 Hz, 60 Hz and 400 Hz). This function helps to improve analytical performance and above all allows measurement when the level of a harmonic order is greater than the level of the fundamental. It is possible to view the harmonic ana lyses of two or four channels simul - taneously Multimeter mode: monitoring of measurements Fault capture is performed by monito - ring 1 or 2 thresholds per channel. The fault duration can be set from 48 ms to approximately 8 days. All the faults cap tured (several thousand can be stored on the SD card) can be recalled by using the Scopix menus. The list of time/date- stamped faults indicates the source and the result of the measurement. This list can be saved in ".txt" format. References to order OX7042-MSD: Oscilloscope, monochrome screen, 2 x 40 MHz OX7042-CSD: Oscilloscope, colour screen, 2 x 40 MHz OX7104-CSDK: Oscilloscope, colour screen, 2 x 100 MHz + SX-Metro Standard state at delivery 1 OX oscilloscope, 1 mains adapter/charger, 1 NiMH 9.6 V –
3.8 A/h battery pack, 1 x 1/10 Probix probe, 1 banana Probix
adapter, 1 set of banana leads, 1 Ethernet crossover cable,
1 USB cable, 1 μSD card with SD-card adapter, 1 magnetic stylus,
1 operating and programming manual Available accessories See pages 107 to 115 20 different automatic measurements Storage and automatic reactivation of acquisitions on threshold overruns (AUTO, NORMAL, SINGLE or ROLL) HX0033, HX0030B Probix/banana adapter, 1/10 voltage probe - 250 MHz
For further details… OSCILLOSCOPES WITH IsOLATED CHAnnELs OX 7062, OX 7102, OX 7104, OX 7202 & OX 7204 Scopix Electronics The 5 models in this range are ideal for the needs of the electronics sector, from PCB design to the development of complex systems. n 156 µV / div input sensitivity for studying signals with very low amplitudes n Bandwidth of 60 to 200 MHz n 2 to 4 isolated channels A high-performance instrument n Sampling rate of 2.5 GS/s per channel in one-shot mode and 100 GS/s in repetitive mode. n 12-bit converter providing a vertical resolution which is 16 times greater than the resolution offered by the conventional 8-bit oscilloscopes on the market. n Isolated channels for simultaneous measurements without signal constraints and with different chassis-earth references for very low sensitivities and for signals up to 1,000 V dc or rms. n 2 MB internal memory, up to 2 GB of data on SD Card and direct storage on PC hard disk via Ethernet (FTP Server/Client) 2 or 4 independent 200 kHz TRMS digital multimeters Just as for the 4 "instrument" modes, a single press on the dedicated key gives access to the multimeter. These 2 or 4-channel TRMS digital multimeters can be used for the following measurements: n amplitude (DC or AC voltage or current, power, temperature, etc.) n resistance, continuity and capacitance n junction or diode tests, etc. Pt 100 sensors or K thermocouples can be used for temperature measurement. The associated recorder can be used to monitor and save any changes in the measurements over periods of 5 minutes to 1 month References to order OX7062-CSD: 2 x 60 MHz oscilloscope OX7102-CSD: 2 x 100 MHz oscilloscope OX7104-CSDK: 4 x 100 MHz oscilloscope + SX-Metro + hard case OX7202-CSD: 2 x 200 MHz oscilloscope OX7204-CSD: 4 x 200 MHz oscilloscope OX7104-CSDO: 4 x 100 MHz oscilloscope + Options OX7204-CSDO: 4 x 200 MHz oscilloscope + Options Standard state at delivery
1 OX oscilloscope, 1 mains adapter/
charger, 1 NiMH 9.6 V-3.8 A/h battery pack, 1 x 1/10 Probix probe, 1 banana Probix adapter, 1 set of banana leads,
1 Ethernet crossover cable, 1 USB
cable,1 µSD-card with SD-card adapter, 1 magnetic stylus, 1 operating and programming manual State at delivery for "CSDO models" Same as "standard" plus 2 x 1/10 Probix probes, Harmonics, Recorder and 50 kb options installed, SX-METRO-P software and a hard case FFT with a Hanning window and a logarithmic scale oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr References to order OX7202-BUS: oscilloscope 2 x 200 MHz HX0190: DB9F and RJ45 connection boards OX7204-BUS: oscilloscope 4 x 200 MHz HX0191: M12 and 8-wire connection boards Available accessories See pages 107 to 115 For further details… OX 7202-BUS & OX 7204-BUS Scopix Fieldbus This specific version for fieldbus integrity testing, SCOPIX BUS offers electrical and physical maintenance of all your fieldbuses: AS-I, DALI, CAN, KNX, ETHERNET, MIL STD1553, ARIN159, USB, FLEXRAY, LIN, PROFIBUS and RS232/485 according to the existing standards: Simplified test Visual help for the steps, the overall result in colour and the result of each test in colour, along with pictograms comparing the value to the tolerance of the standard: , or . Help at connection with a reminder of the input channels and the assembly diagrams for each bus. Help with connection to the field- buses using cards equipped with SUBD9 or RJ45 or M12 connectors or 8-wire screw connectors: HX0190 and HX0191. Help with troubleshooting in the User Manual and the booklet of bus des- criptions by standards. Link quality test The diagram of the eye offers a visual diagnosis to check and assess the transmission quality of a digital bus. All the Scopix communication tools are provided as standard, with: n SX-BUS bus creation and modifica- tion software for better adaptation to the standards and any changes to them: modification of the standard limits, measurement tolerances in MIN/MAX and % on SCOPIX BUS n Display of the results from the last analysis: these results can be sa- ved in a ".htm" file in the internal memory (1 MB), on the SDCard (2 GB max.) or on an FTP server. OSCILLOSCOPES WITH ISOLaTED CHaNNELS Multi-function oscilloscopes: - oscilloscope, multimeter, recorder & bus analyser; - 200 MHz on 2 or 4 channels; - memory depth: 50 kpts.
For further details… Advantages of the Patented Probix System Scopix portable oscilloscopes benefit from Probix smart accessories which offer users a host of innovative functions guaranteeing simplicity, effectiveness, versatility and safety. The Probix system, with its smart probes, accessories and adapters, ensures quick, error-free implem- entation of your instrument. With this "plug and play" measure- ment system, the probes and adap- ters are recognized immediately as soon as they are connected. The ins- trument does not just identify them, however. It also gives information on their specifications. Active safety is built-in, notably in the form of safety information and recommendations for users based on their specific configuration. The coefficients, scales, units and channel configurations are managed automatically This system also allows users to power the accessories directly from an oscilloscope, without a battery or additional mains adapter. Some Probix accessories include three control buttons directly ac- cessible on the probe. For example, the first two control buttons on the probes are used for direct modifica- tion of the parameter settings for the channel to which they are connected. The Probix DC current sensors are self-powered by the oscilloscope. HX0034 HX0094 HX0096 OSCILLOSCOPES WITH IsOLATED CHAnnELs Probix current measurement HX0034: 0.02 A to 60 ARMS AC/DC current clamp / 1 MHz HX0072: 5 A to 3,000 ARMS AmpFLEX™ AC current sensor / 200 kHz HX0073: 1 A to 300 ARMS MiniAmpFLEX AC current sensor / 3 MHz Probix Adapters HX0094: Probix 4-20 mA (process) adapter HX0096: Probix BNC adapter/100 mV/A (standard sensors) HX0072 oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr For further details… Advantages of the Patented Probix System Probix voltage measurement Probix voltage probe HX0030B: 1/10 voltage probe, 1,000 V CAT II, 600 V CAT III,
250 MHz
HX0071: Industrial Accessories Kit for HX0030A probes (wire grip, banana plug, 50 cm earth connection) HX0130: 1/10 electronic voltage probe, 300 V CAT III, 500 MHz Probix BNC HX0031: Probix adapter for BNC cables HX0032: Probix BNC adapter with built-in 50 Ω load Probix Banane HX0033: Probix adapter for banana leads, 600 V CAT III HX0093: Probix adapter with 300 Hz filter (PWM systems),
600 V CAT III
HX0095: Probix adapter for banana leads, 1,000 V CAT II Temperature measurement HX0035B: Probix / K Thermocouple adapter HX0036: Probix / Pt100 Probe adapter Example of application With a Probix AC/DC current probe powered by the oscilloscope and a Probix 1/10 1,000 V voltage probe, thanks to the automatic scaling, unit management and the appropriate Math function (multiplication), you can view the instantaneous power in real time and measure the value. When 2 channels are multiplied, it is possible to view the scaled result, with its physical unit (e.g. W) and the original curves (in this case, the current and the voltage). HX0030 HX0130 HX0071 HX0031 HX0033 OSCILLOSCOPES WITH ISOLaTED CHaNNELS
A multiple instrument for complete, precise diagnosis A multi-channel 200 kHz TRMS digital multimeter HX0075 power measurement (Option) HX0028 harmonic analysis (Option) HX0029 recorder (Option) Extension of the acquisition memory HX0077 (Option) The 4 Scopix modes In multimeter mode, the power measurements are developed as follows: n Single-phase power n Three-phase power on balanced network without neutral n Three-phase power on balanced network with neutral n 3-wire three-phase power (2-wattmeter method) A memory of 50,000 points. Display of apparent, active and reactive power values and the PF Selection of the type of network supplying the load Recorder mode: 50,000-sample acquisition, maximum resolution 40 μs, x100 zoom (one mains cycle) The "vertical zoom" (front-panel button) can be used to adjust the dynamic range as required (0-100 %, 0-50 %, 0-25 %, or 0-10 %). Specifications 2 or 4-channel multimeter 8,000 counts - TRMS AC, DC and AC 600.0 mV to 600.0 Vrms or 800 mV + DC voltages to 800.0 Vdc - accuracy Vdc 0.5% R + 5 D – bandwidth 200 kHz General 2 or 4 channels – 8,000 counts max. specifications & Min/Max bargraph - TRMS – Time/date-stamped graphic recording Resistance 80.00 Ω to 32.00 MΩ- accuracy 0.5% R + 25 D - 10 ms quick continuity test Other measurements Capacitance from 5.000 nF to 5.00 mF / Frequency 200.0 kHz / 3.3 V diode test Specifications Multi-channel 2 or 4 depending on model analysis 61 orders – frequency of fundamental from 40 to 450 Hz in auto or manual mode Processing Permanent display: total RMS value & THD selected order: %F, phase, frequency, Vrms Specifications Acquisition rate Sampling interval of 800 μs to 17 min 51 s – (standard memory 2,500 points) Sampling interval of 40 μs to 53.5 s - (with 50,000-point memory extension) Recording duration 2 s to approx. 1 month Acquisition mode Conditioned by thresholds or windows "Normal" acquisition or up to 500 faults Processing Time/date-stamped graphic recording, conversion and units of physical quantities, measurements using cursors and event searches, file format compatible with standard spreadsheet (“.txt”) OSCILLOSCOPES WITH IsOLATED CHAnnELs oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr SX METRO Virtual printer PC software The data processing software for all METRIX® oscilloscopes which allows you to: n View the curves n Display the curves on the PC in real time with the oscilloscopes n Control the oscilloscope remotely via the PC n Load a configuration into the oscilloscope n Import curves stored in the oscilloscope's memory, using the following types of "image" files: n Store the curves on the PC in text format n Perform mathematical processing such as the FFT of the signal displayed n Transfer the data (curves or FFT) into Excel n Signal demonstration board for METRIX oscilloscopes: HX0074 For printing ".gif" and ".bmp" files from SCOPIX/OX6000 on a network printer linked to a PC. The software installed on a computer equipped with the drivers for the network printer provides a direct gateway between the oscilloscope and the printer, transforming the PC into an LPD server. This software is a virtual print server which processes the file so that no action is required from the user. It then sends the prepared file to the network printer. As a result, after configuring the oscilloscope, it is possible to send screenshots directly for printing. This method is simple, quick and effective. It is delivered on CD with its user manual. ACCESSORIES FOR OSCILLOSCOPES USB-RS232 or Ethernet link File name Contents a curve which will be displayed in the active graph a recording which will be displayed in a new graph an instrument configuration a screenshot a graph with its curves and comments a curve in persistence mode Reference to order SXMETRO/P
(available from Google Store) Software not requiring installation To control a fleet of instruments directly via a web browser (oscilloscopes equipped with an Ethernet connection). Application for remote control of an instrument using a PC. Application for remote control of an instrument using a PC. ScopeNet for remote dialogue and parameter settings. This software can be used to view the curves in real time, perform measurements and analyses, capture screens and control METRIX® oscilloscopes from your tablet or smartphone. With this application, you can monitor the curves and measurements on a METRIX® oscilloscope from the OX7000, OX6000B or MTX105x series via an Ethernet link. ACCESSORIES FOR OsCILLOsCOPEs The APPLICATIONS supplied with the SCOPIX-MTX105X and OX6000 models Accessories USB/microUSB adapter: HX0080 MicroSD/SD adapter: HX0079 oSCilloSCoPES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr Spectrum analysis Spectrum analysis can be used to measure the band, detect disturbance lines, quantify phase jitter by direct reading, check the steps, determine the rated frequency, search for residual lines for comparison, etc. Heterodyne spectrum analyser Spectrum analysis involves moving a narrow bandwidth filter in front of the signal to be analysed. However, because of the difficulty of producing a narrow bandwidth filter with an adjustable mid-band frequency, the problem is avoided by "heterodyning". With this technique, the bandwidth filter has a fixed mid-band frequency of F0 and the signal to be analysed is modified by modulation, so that the different frequency components are successively modulated to the frequency F0. To achieve this, a multiplier is used which outputs the sum and the difference of the frequencies applied to the two inputs, resulting from the trigonometric relation: cos(a)cos(b) = (1/2)[cos(a+b) + cos(a-b)]. The analytical filter The analytical filter is also called the resolution filter. The narrower the filter, the finer the analysis and the closer you get to the shape of the line analysed (because the filter itself resembles a line). Using different reasoning, it could also be said that a signal passing through an extremely narrow filter can only come out as a pure sine wave, represented by a line! It is tempting to use a narrower filter to analyse a signal, but compromises need to be made. The narrowness of the filter limits the amount of data that it can supply per second, which means that, to obtain a large number of measurement points (i.e. better frequency resolution), more time will be necessary with a narrow filter than with a wider filter. Width of analytical filter SPECTRUM ANALYSER CONNECTED TO a PC POWER (dBm) 3 dB 10 kHz / Div. Resolution filter band (here 3 kHz) Block diagram of a heterodyne spectrum analyser Oscilloscope Peak detection Bandwidth filter centred on F0 Signal to be analysed Multiplier Summer Ramp generator
Noise power and power of a line The analytical filter indicates the power of the F0 line when it is centred on it (leaving aside the filter losses which can be compensated). Whatever the width of the filter, the maximum height of the curve on screen will correspond to the power of the line. Noise measurement depends on the width of the analytical filter This means that phase jitter can be measured with the spectrum analyser, in dBc/Hz, which is the difference in dB between the F0 line power measurements in dBm and the noise power in dBm/Hz at a given distance from the carrier. Video filter This serves to smooth the curve on the screen, particularly at the noise level. It has no effect on the actual measurement, as it only applies to the on-screen display of the curve. However, it may affect the sweep time: a 10 Hz video filter will not deliver more than 10 data items per second, so if 1,000 points are necessary to plot the curve, it will not be possible in less than 100 seconds. Noise measurement with several analytical filters SPECTRUM ANALYSER COnnECTED TO A PC POWER (dBm) Carrier NOISE lAboRAtoRy inStRumEntS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr SPECTRUM ANALYSER CONNECTED TO a PC n Particularly compact and economical "screenless" instrument n User interface via PC: "Plug & Play" USB connection, large high- resolution colour display n 4 simultaneous measurements (Peak auto, Marker, 2 difference cursors) n Frequency range from 400 kHz to 1 GHz n High stability with frequency drift limited to ±5 ppm/year n Wide dynamic range for measurement, from -90 dBm to +20 dBm n 6 sweep speeds, 3 analytical filters and 3 video filters, built-in FM demodulation n Ideal for EMC testing When coupled with the H-field probes, the MTX1050-PC analyser can be used to carry out EMC prequalification tests. MTX 1050 The lightweight, portable MTX1050 general-purpose spectrum analyser is particularly suitable for the needs of small businesses and technical education. PEAK cursor Free cursor DELTA cursors CAT II
HX0082: H-field probes kit, 3 GHz HX0083: 20 dB amplifier for HX0082 probes Standard state at delivery
1 MTX, 1 mains power cable, 1 CD-Rom containing the PC
application software, 1 FM antenna with BNC connection, 1 user manual Reference to order MTX1050-PC: 1 MTX 1050PC spectrum analyser Available accessories See pages 102 to 103 For further details… SPECTRUM ANALYSER COnnECTED TO A PC Specifications MTX 1050 Frequency Display Colour display, high resolution, large dimensions, on PC screen Up to 5,000-point sweep in horizontal resolution (depending on speed) Bandwidth 400 kHz to 1 GHz Resolution on central frequency value 4 1/2 digits / 10 kHz maxi Internal frequency Accuracy ±0.625 10-6 Frequency stability ±5 ppm / 1 year Frequency span Zero Span, 1 MHz to 100 MHz / div - sequence 1-2-5 Resolution Filters 12 kHz, 120 kHz and 1 MHz Video filters 1 kHz, 10 kHz and 300 kHz Level Dynamic range for input 3 ranges from -90 dBm to +20 dBm Noise floor level Without amplifier: -80 dBm (dynamic range for measurement) With amplifier: -95 dBm Dynamic range for display 50 dB and 100 dB Harmonic response < -40 dBc for a level of -20 dBm Non-harmonic response < -70 dBc (< -600 dBc on identified frequencies) Input Max. admissible power +25 dBm permanent, ±30 Vdc Impedance 50 Ω rated Input attenuation One 20 dB-rated attenuator, one 20 dB-rated amplifier Connector BNC Markers / Modes 4 simultaneous cursors / 1 automatic "Peak" detection marker, 1 cursor "locked" to the trace and 2 delta cursors Functions Data storage On PC, unlimited number, with explicit names Storage and comparison of reference spans 100 to 5,000 samples per sweep (depending on sweep speed) Traces Averaging (factors 2 to 64 / noise suppression and improvement of dynamics Comparison to a reference and measurement of deviations (frequency & amplitude) Calculation of difference (Spectrum – Reference) and associated measurements Screenshot with all settings - Transfer to Excel PC communication "Plug and Play" USB as standard Mains power supply 230 Vac, ±10 %, 50/60 Hz, approx. 4 W Safety / standards IEC 61010-1 - CAT II / NF EN 61326-1: 98 Dimensions / Weight 270 (L) x 63 (H) x 215 (W) mm / 1.7 kg lAboRAtoRy inStRumEntS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr Measurements with the HX0082 contact probe Measurements with the HX0083 proximity probe up to 10 cm from the target SPECTRUM ANALYSER FOR EMC PREQUaLIFICaTION TESTS A set of instruments specially designed for EMC prequalification tests These tests may take place throughout the design and development of a product. Prequalification tests help to save time and make sure that the finished product will comply with the applicable standards. These tests take into account all aspects which help to limit disturbances:
- Choice of components and floorplan on printed circuit boards
- Reduction of cable lengths and use of screened cables when possible
- Separation of circuits/cables of different types (e.g. analogue or digital)
- Checking of electrical continuity (e.g. connec- tions, welds, etc.)
- Verification of the floorplan and screening, etc. This is not an exhaustive list. Any measurements that may reduce electromagnetic fields should be envisaged to ensure that the product operates correctly. The tests are divided into 2 main categories: immunity tests and emission tests. They are also performed in 2 distinct modes: “conducted mode”, covering disturbances in the cables or printed- circuit traces, and "radiated mode" for the electro- magnetic field in the air. HX0082 near-field probes & HX0083 amplifier The HX0082 kit comprises 2 near-field probes (30 MHz – 3 GHz). The proximity probe can be used to measure radio-frequency magnetic fields. It can be positioned up to 10 cm from the target. The contact probe is designed for precise measure- ments on chip floorplans or traces. Spectrum analyser and near-field probes MTX 1050, HX 0082 & HX 0083 Specifications HX 0083 Power supply voltage 7.5 to 18 V Current consumption 50 mA Max. input voltage 25 Vdc Gain 20 dB Noise 4.5 dB
LaBORaTORY INSTRUMENTaTION Generator basics Function generators are among the most widely-used test and measurement instruments. They can generate varied characteristic waveforms in order to test the operation of electronic systems, from very low frequencies of just a few mHz up to 20 MHz or more. It allows users to adjust the amplitude of these signals up to 20 V or more, possibly with the presence of a DC component. In addition, they may also provide modulations or specific functions. Direct Digital Synthesis (DDS) function generator Direct Digital Synthesis (DDS) function generator Generation of a 21 MHz signal with direct digital synthesis (DDS) Basic principle: DDS function generators generate periodic signals at precise frequencies by choosing samples in the memory rather than producing all the samples of a signal. This technique offers exceptional accuracy and stability, high spectral purity, low noise and excellent frequency agility. It is possible to modify the frequency without phase discontinuity. It is important to note that signal generation with the DDS method differs significantly from the method used by an arbitrary signal generator. For arbitrary signal generation, each sample of the signal period built and stored in the memory is generated sequentially. For signals generated with DDS technology, a single signal period is stored in the memory, but only certain samples are generated to create the waveform and the required frequency, as shown in the illustration below: lAboRAtoRy inStRumEntS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr GENERATORS LaBORaTORY INSTRUMENTaTION A few definitions Signal waveforms The generator can typically generate sine, triangle and square waveforms, as well as their usual derivatives. Frequency range (expressed in Hertz (Hz) This is the difference between the minimum frequency and maximum frequency that the generator is capable of producing. This frequency range is defined for a sinusoidal waveform. It should be noted that a smaller frequency range is usually specified for triangular or square waveforms. The minimum frequency, which may be just a few mHz, is used to simulate slow phenomena (mechanical or physical) or to control slaving (for example, a triangular ramp profile). Resolution This is the smallest measurable value difference. It is expressed in digits and its absolute value depends on the frequency range used. For the GX320, for example: 5-digit resolution at 20 MHz corresponds to a 1 kHz increment. Frequency accuracy This corresponds to the difference between the true value of the signal's frequency and the value displayed. It mainly depends on the quality of the oscillator used, for which short-term and long-term stabilities are defined, expressed in ppm (parts per million). For example, for the GX320: +/- 20ppm when F > 10 kHz. SWEEP function The "SWEEP" function can be used to generate a frequency sweep in rising or falling mode. This sweep can be controlled by the generator according to a linear or logarithmic law or on the basis of an external sawtooth or triangular signal applied via a dedicated BNC connection. Types of modulation AM: Amplitude Modulation FM: Frequency Modulation FSK function: Frequency SKip controlled internally or externally. PSK function: "Phase SKip" whose value is controlled by an internal or external command signal. BURST function The BURST function can be used to generate pulse trains: users define the train generation period and the number of pulses in the train. It also provides a means of generating a signal with a very large duty cycle (1 brief pulse with a long repetition period). GATE function This superimposes over the current function a start/ stop command for the AC component of the MAIN OUT signal. This function can be controlled internally or by a TTL signal injected on a dedicated BNC connection. MASTER/SLAVE function This can be used to synchronize several GX 320s set up in a "cascade" arrangement. The generator used as the "Master" supplies the other "Slave" instruments with the clock (Clk) and a synchronization signal (Ctrl). This enables all the generators to start up at the same time and allows users to control their phase offset. Num = number of pulses Time = generation period
GENERATORS LABORATORY InsTRUMEnTATIOn Specifications GX305 GX310 GX320 Number of channels 1 1 1 Max. frequency (MHz) 5 10 20 Display LCD (125 x 45 mm) - 5 digit Signal waveforms sine, triangle, square & logic+TTL Sweep • • • AM/FM modulation • FSK/ASK function • BURST function • GATE function • MASTER/SLAVE function • Frequency meter 100 MHz Arbitrary function SX-GENE software Easywave software Pages 86-87 Specifications GX1025 GX1050 DOX3104 DOX3304 Number of channels 2 2 1 Max. frequency (MHz) 25 50 25 Display 3.5" colour TFT 8” Signal waveforms sine, triangle, square, ramp, pulse, white noise, Arb Sweep • • AM/FM modulation • • FSK/ASK function • • BURST function • • GATE function • • MASTER/SLAVE function Frequency meter 200 MHz Arbitrary function • • • SX-GENE software • • Easywave software • Pages 88-89 62 Function generators Arbitrary function generators lAboRAtoRy inStRumEntS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr LOW-FREQUENCY GENERATORS n Frequency range from 0.001 Hz to 10 MHz (GX310) or 20 MHz (GX320) n DDS technology with a frequency accuracy of +/-20 ppm n Adjustment of stable frequency to the nearest digit n "Logic signal" function for direct adjustment of the high and low levels (TTL, CMOS, etc.) n 100 MHz frequency meter, 300V CAT I n Versions programmable via USB link with the standard SCPI protocol n AM/FM modulation (GX320) n GATE, BURST, FSK and PSK functions (GX320) n Storage of 15 complete instrument configurations (GX320) Specific innovative function: Adjustable-phase synchronisation of several generators in a cascade arrangement (GX320. Ergonomics: uniquely easy to read! The GX generators have a large LCD screen (125 x 45 mm) offering exceptionally easy reading thanks to the main display's 5 digits 20 mm high. In addition, the GX generators can simultaneously display all the parameter settings (VDC, V rms or Vpp, waveform, etc.). GX 305, GX 310 & GX 320 DDS function generators Multi-function, stand-alone, innovative laboratory generators- testers! Synchronization of several generators in a cascade arrangement The "SYNC" function on the GX 320 allows several generators to be set up in a cascade arrangement to make a variable-phase multiple-signal generator. A first GX 320, used as the "Master", provides the other "Slave" instruments with the clock used to generate the signals. It also supplies the synchronizing pulse to start all the instruments simultaneously. In this way, the phase shift of each signal is controlled. Example 1: simulation of a three-phase signal Channel 1: master (0°) Channel 2: slave1 (120°) Channel 3: slave2 (-120°) Example 2: Fourier synthesis Synchronization of the generators (3 in this example) allows simulated synthesis of a square signal from its primary harmonics. GX 320 Master GX 320 Slave 1 GX 320 Slave 2
For further details… LOW-FREQUEnCY GENERATORS Specifications GX 305 / GX 310 GX 320 Human-machine interface Display LCD (125 x 45 mm) – Adjustable brightness – Frequency display with 5 digits 20 mm high Adjustment of signal parameters Continuous by encoder, auto-ranging for Frequency and Level, selection of increment digit (F, P, N, etc.) BNC output terminals on front panel TTL & Sweep Out outputs TTL, Sweep, Clock and Synchro outputs BNC input terminals on front panel VCF in input VCG, Gate; Clock and Synchro inputs Continuous signal generation Frequency 0.001 Hz to 10.000 MHz (9 ranges - GX 305) 0.001 Hz to 20.000 MHz (11 ranges) 0.001 Hz to 10.000 MHz (10 ranges - GX 310) Resolution / Accuracy 5-digit display – resolution from 1 mHz to 1 kHz depending on range / 10 kHz, ± 30 ppm for F < 10 kHz Amplitude 1 mV to 20.0 Vpp with open circuit in 3 automatic ranges –3-digit display Vpp or Vrms – Max. resolution 1 mV Flatness < 5 % for 1 mHz < F < 10 MHz , and ± 0.5 dB typ. up to 20 MHz (GX 320) (specs for a level from 0.1 Vpp to 20 Vpp) Signal form Sine / Triangle (max. frequency 2 MHz) / Square & "LOGIC" / TTL output Frequency sweep Modes LIN (linear) or LOG (logarithmic) INT internal sweep "Sawtooth" or "Triangle" mode – Unlimited span between "F Start" & "F Stop" Sweep time adjustable from 10 ms to 100 s EXT external sweep Sweep by signal < 15 kHz, amplitude ± 10 V Modulation Internal AM modulation Modulation by a 1 kHz sine signal Modulation rate 20 % or 80 % External AM modulation Modulation by a signal < 5 kHz, with amplitude ± 10 V for 0 to 100 % modulation (VCG IN) Internal FM modulation Modulation by a 1 kHz sine signal Unlimited span between "F Start" & "F Stop" External FM modulation Modulation by a signal < 15 kHz Amplitude ± 10 V (VCG IN) SHIFT K function Frequency hop, internal or external phase jump Burst function Internal BURST 1 to 65,535 pulses Period of pulse trains 10 ms to 100 s External BURST 1 to 65,535 pulses – Synchro/Period by a TTL signal with frequency < 1 MHz (VCG IN) Gate function Validation of AC component from "Main Out" by a TTL signal with frequency < 2 MHz (GATE IN) Synchro function Cascade configuration Maximum frequency of generated signals 100 kHz of several GX 320s Adjustment of phase shift to ± 180° (resolution 1°) External frequency meter Measurement range / accuracy 5 Hz to 100 MHz / ± 0.05 % + 1 digit Safety / max. admissible voltage 300 V CAT I / 300 V rms General specifications Configuration memories Storage/Recall of 15 complete instrument configurations Communication interface "USB A/B" link for the programmable versions (P) and Ethernet for the GX 320-E Mains power supply 230 V ± 10 % (or 115 V ± 10 %) – 50/60 Hz – 20 VA max. – Removable lead Safety / EMC Safety as per IEC 61010-1 (2001) – EMC as per EN 61326-1 (2004) Mechanical specifications 227 (L) x 116 (H) x 180 (W) mm – Weight 2.8 kg Warranty 3 years Accessories and replacement parts AG1066-Z: set of 2 BNC-banana leads with rear connection HX0106: Set of 2 BNC-BNC leads 1 m long HX0107: Set of BNC-banana adapters HA2004-Z: Set of 3 BNC T-fittings Standard state at delivery Standard versions – 1 function generator, 1 mains power cable, 1 CD-Rom containing: 1 user manual in 5 languages, 1 programming manual in FR + EN, LabWindows CVI / LabView drivers Programmable versions – 1 function generator, 1 mains power cable, 1 CD-Rom containing: 1 user manual in 5 languages, 1 programming manual in FR + EN, LabWindows CVI / LabView drivers, 1 USB A/B cable - Ethernet version – The same + 1 Ethernet cable References to order GX305: 5 MHz function generator GX310: 10 MHz function generator GX310-P: Programmable 10 MHz function generator GX320: 20 MHz function generator GX320-E: Programmable 20 MHz function generator Available accessories See page 114 LOW-FREQUENCY GENERATORS lAboRAtoRy inStRumEntS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr aRBITRaRY FUNCTION GENERATORS GX 1025 & GX 1050 DDS function generators These multi-function, communicating laboratory generators- testers with built-in frequency meter are ideal for all R&D lab, testing and production applications, as well as for technical training and higher education. n Large 320 x 240 mm TFT LCD screen with high contrast for better visibility, intuitive front panel and simple use n DDS technology on 2 outputs for coupling or duplication n Generation of standard signals such as sine, square and triangle, as well as more complex signals: pulse, ramp or white noise n Generation of arbitrary signals which are precise, stable and pure, with low distortion at a sampling rate of 125 MS/s on 14- bit resolution n Internal SWEEP wobble modulation: external or manual, linear or logarithmic n The integrated AM, FM, PM, ASK and FSK modulation functions can be used to generate modulated signals very easily without an independent modulation source n Memory depth of up to 16 kpoints, allowing reconstruction or simulation of any type of complex signal n Generator user interface and integrated help in English n USB interface on front panel for data storage n USB interface on front panel for programming and control of the instrument via the SX-GENE software SX-GENE v2.0 can be used to control a GX 1025 or GX 1050 arbitrary function generator, save and recall configurations and generate arbitrary signals. It allows: n Data transfer in .arb files (from the generator to the PC) n Recovery of a signal from a METRIX® oscilloscope curve (.trc file transferred into the generator) n Configuration of the generator (.cfg) n Recovery of an arbitrary signal stored in one of the generator's 10 memory locations GX 1050, 50 MHz GX 1050 (rear view) GX 1025, 25 MHz
GENERATORS ARBITRARY FUnCTIOn Specifications GX 1025 GX 1050 Human-machine interface Display Large high-contrast 3.5 ‘’ TFT colour screen / Resolution 320 x 240 Controls on front panel 18 direct-access buttons, 1 rotary button Adjustment of signal parameters Continuous adjustment by the encoder and/or numeric keypad BNC output terminals on front panel Generator outputs 1 & 2 - Separate adjustment (waveform, f, phase, amplitude, etc.), coupled or duplicated BNC I/O terminals on rear panel TTL-compatible trigger and synchronization outputs Continuous signal generation Signal types Sine, Square, Triangle, Ramp, Pulse, White Noise, Arbitrary Signal (48 pre-installed waveforms) Arbitrary signal generation Resolution / Sampling rate 14 bits / 125 MS/s Memory 16k memory depth (512k on CH1 only) - Storage of predefined or specific signals on USB key Editing of signals with SX-GENE Acquisition, transfer & modification of a signal acquired from an oscilloscope (OX6000, OX7000, SCOPEin@BOX) Graphical or mathematical editing with the SX-GENE software Signal frequency Sine from 0.001 mHz to 25.000 MHz, Sine from 0.001 mHz to 50.000 MHz, Frequency range Triangle 300 kHz, Noise and Square 25 MHz, Triangle 300 kHz, Noise and Square 50 MHz, Pulse 10 MHz, Arbitrary Signals 5 MHz Pulse 20 MHz, Arbitrary Signals 5 MHz Resolution / accuracy 7-digit display – resolution from 1 mHz to 1 kHz depending on frequency range ± 20 ppm for F > 10 kHz , ± 30 ppm for F < 10 kHz Long-term drift ± 100 ppm / year Temperature coefficient < 5 ppm / °C Amplitude Voltage levels Output 1 = 2 mVpp ~ 10 Vpp 50 Ω) 2 mVpp ~ 20 Vpp (open circuit) Output 2 = 2 mVpp ~ 3 Vpp (50 Ω) 2 mVpp ~ 6 Vpp (open circuit) Flatness < 0.1 dB for f < 100 kHz Vdc offset Output 1 = ± 10 Vdc (open circuit), Output 2 = ± 3 Vdc (open circuit) – accuracy ± 1% ± 1 mV Impedance / Protection 50 Ω / Protection against short-circuits Signal characteristics Sine Distortion < 0.2 % typical for f < 20 kHz, and harmonics < -50 dBc for DC < f < 25 MHz (level < 1 Vpp) Triangle (max. frequency 2 MHz) Linearity error < 1% max Square & pulse Rise time < 12 ns (typ.) – Duty cycle 20-80% (DC < f < 20 MHz) – Pulse 20 ns to 2,000 s Modulation (internal or external source) Carrier: Sine, Square, Triangle, Arbitrary (except DC) AM modulation Modulated signals: Sine, Square, Ramp, Noise, Arbitrary (2 mHz-20 kHz) Modulation depth: 0% to 120% Carrier: Sine, Square, Triangle, Arbitrary (except DC) FM modulation Modulated signals: Sine, Square, Ramp, Noise, Arbitrary (2 mHz-20 kHz) Modulation depth: 0% to 120% Frequency offset: 0 to 12.5 MHz Frequency offset: 0 to 25 MHz Carrier: Sine, Square, Triangle, Arbitrary (except DC) FSK modulation Modulated signals: 50% of duty cycle (2 mHz to 50 kHz) Carrier: Sine, Square, Triangle, Arbitrary (except DC) ASK modulation Modulated signals: 50% of duty cycle (2 mHz to 50 kHz) Carrier: Sine, Square, Triangle, Arbitrary (except DC) PM modulation Modulated signals: Sine, Square, Ramp, Triangle, Noise, Arbitrary (2 mHz-20 kHz) Phase offset: 0 to 360° Other functions Sweep Carrier: Sine, Square, Ramp, Triangle, Arbitrary (except DC) - Type: Linear/Logarithmic Direction: Increasing or Decreasing - Sweep time: 1 ms to 500 s - Trigger: Manual, External, Internal Burst Signals: Sine, Square, Ramp, Arbitrary (except DC) - Type: Short (1-50,000 cycles), Infinite, Gate - Phase start/stop: -180° to +180° - Internal period: 1 μs to 500 s ± 1% External frequency meter Measurement range / resolution 100 mHz to 200 MHz Sensitivity / Input impedance 20 mV rms for 100 mHz < f < 100 MHz, 40 mVrms beyond / 1 MΩ General specifications Data storage Storage of predefined or specific signals and complete instrument configurations on USB key Communication interface USB Device, USB host Software The SX-GENE software can be downloaded free of charge from our support website, along with the LV and LW drivers Mains power supply 100~240 VACRMS 45~440 Hz CAT II - < 30 W Mechanical specifications 229 mm x 105 mm x 281 mm - 2.8 kg Warranty 1 year Standard state at delivery
1 GX delivered with 1 mains power
cable, 1 USB cable, 1 user manual, 1 programming manual on CD-Rom and the SX-GENE v2.0 software References to order GX1025: 25 MHz arbitrary function generator GX1050: 50 MHz arbitrary function generator Available accessories See page 114 aRBITRaRY FUNCTION GENERATORS lAboRAtoRy inStRumEntS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr Power supply basics DC power supplies offer constant, controlled current and voltage output. A power supply can be seen as an AC/DC converter which takes energy from the electrical network (230 V/50 Hz) and passes on part of that energy. The linear technology used in our AX 5xx power supplies is based on a toroidal transformer which reduces the weight and improves efficiency while providing the following features:
- Protection against short-circuits, overloads and overheating
- Double-well safety output terminals and double- well male safety earth terminal
- Toroidal transformer compliant with the EN60742 standard with outputs double- insulated in relation to the mains supply: no forced ventilation to reduce noise and low radiation
- Serial or parallel coupling of the outputs and loop control of the outputs with the Tracking mode. A programmable DC power supply is adjustable and offers multiple functions. These power supplies are usually equipped with independent outputs:
- With an adjustable voltage level
- or a fixed voltage. The power supply can be used to power logic circuits for voltage or current requirements of different levels. Output modes
- Independent mode: the output voltage and current on each channel are controlled separa- tely. The level of insulation between the output terminal and the chassis, or between output terminals, is fixed.
- Tracking mode: the two CH1 and CH2 outputs are automatically connected in series or in parallel. Coupling
- Series: the output voltage is doubled
- Parallel: the output current is doubled. LaBORaTORY POwER SUPPLIES Selection guide AX 501 AX 502 AX 503 AX 1360-P 1 channel • • • • 2 channels • • • 2 channels + 1 fixed • • Tracking mode • • • Programmable • Ventilation • Memory • USB •
For further details… n Linear technology: stability, low noise, good response to current demand n Active protection against short-circuits, overloads and overheating n Outputs with double insulation in relation to the mains n Series or parallel output coupling for generating up to 60 V / 2.5 A or 30 V / 5 A n Coupling of the two 30 V outputs in "tracking" mode in order to adjust them simultaneously (master/slave) n Adjustable current limitation on the 30V outputs n A third adjustable 2.7 V-5.5 V/5 A output on the AX 503 can be used to power logic circuits (TTL/ CMOS) n Compact and lightweight n Dual-well safety terminals n An earth terminal with reversed polarity to avoid connection errors As well as being particularly rugged, these power supplies are also lightweight, economical and based on the latest technology! The AX 501, AX 502 and AX 503 laboratory power supplies with 1, 2 or 3 outputs offer electronic limitation of the current in the event of short- circuit and temperature control in the event of overload or overheating. Their linear technology is based on a toroidal transformer which halves their weight and improves their efficiency. References to order AX0501A: AX501 AX0502A: AX502 AX0503A: AX503 AX0503F: AX503FSpecific accessory P01295073A - Reverse-polarity earthing cable (green/yellow) Standard state at delivery
1 AX power supply, 1 power cable,
Specifications AX 501 AX 502 AX 503 AX 503F Technology Linear Display Green and red LEDs - 3 digits Outputs 1 x (30 V/2,5 A) 2 x (30 V/2,5 A) 2 x (30 V/2,5 A) 2 x (30 Vdc/2.5 A fixed 1 x (2,7 to 5,5 V/5 A) 3.3 Vdc fixed/5 A fixed Output coupling Series or parallel Output tracking Yes ("track" mode) Special features Electronic protection against short-circuits, overloads and overheating. Output double insulated from mains Toroidal transformers (no forced ventilation and low emissions) Double-well safety terminals IEC 61010 - 1 safety CAT I, 100 V Power supply 110, 230 V Dimensions (H x L x W) 120 x 225 x 270 mm Weight 4 kg 4,5 kg 6 kg Warranty 3 ans AX 501, AX 502, AX 503 & AX 503F lAboRAtoRy inStRumEntS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr LaBORaTORY POwER SUPPLY AX 1360-P Programmable power supply Performance and simplicity at the best price! n 2 adjustable outputs (0-30 V) and 1 selectable fixed output (2.5 V / 3.3 V / 5 V) n Bright colour display of the currents and voltages simultaneously on 3 digits n Simplified use thanks to serial or parallel coupling without leads n Quicker setup with 4 configurations available for recall on the front panel n High stability and low drift over time, whatever the mode n Protection against voltage surges, overheating and short-circuits n Ventilation control according to the output power n USB communication References to order AX1360-P Standard state at delivery AX1360-P: 1 programmable power supply, 1 power cable, 1 USB cable,
1 CD-Rom containing the user manual and the LV/CVI drivers
Display Digital with LEDs – Simultaneous voltage and current in colour Number of outputs 3 Voltage control Output 1 0 – 30 V Output 2 0 – 30 V Output 3 2.5 V / 3.3 V / 5 V Current control Independent Parallel Output 1 3 A 6 A Output 2 3 A 6 A Output 3 3 A – Accuracy Voltage ±(0.5 % reading + 2 digits) Current ±(0.5 % reading + 5 digits) Resolution Voltage 10 mV (0 to 9.99 V) – 100 mV (10 to 30 V) Current 10 mA Ripple and noise Voltage < 1 mVrms Temperature coefficient Voltage < 300 ppm / °C On-load Independent and parallel Voltage control < 0.1 % +5 mV Current control < 0.2 % +3 mA Protection Short-circuits Current limitation and visual indicated by red LED Overcurrent Fuse "SAVE/RECALL" function No. of stored configurations 4 Technical Specifications Current and voltage adjustment Output 1 and 2 by potentiometers, Output 3 by switch Interface / Software USB Mains power source 110 V – 220 V / 50 Hz – 60 Hz Safety / Protection IEC 61010-1 300 V CAT II / Fuse Mechanical specifications Dimensions: 310 x 250 x 150 mm – Weight: 7.5 kg Warranty 1 year For further details…
COS-PHI METER, BOXES, SHUNTS Training boxes and shunts Double changeover switch box P03197529A 2 switches with make/break/ non-locking make Simple changeover switch box P03197530 A 1 changeover switch with make break/reverse make Inductance box P01197451 BL 07: 7 decades - 1 μH to 10 H G = null galvanometer BK = K ratio box with K = R2/R1 R3 = resistance box X = resistance to be measured with X = K x R3 B1 = simple changeover switch box B2 = double changeover switch box Bat = power supply Simple resistance boxes P03197521A 0.1 to 1 Ω P03197522A 1 to 10 Ω P03197523A 10 to 100 Ω P03197524A 100 to 1,000 Ω P03197525A 1 to 10 kΩ P03197526A 10 to 100 kΩ P03197527A 100 to 1,000 kΩ P03197528A 1 to 10 MΩ 4, 5, 6 and 7-decade resistance boxes P01197401 BR 04 : 4 decades 1 Ω to 10 kΩ P01197402 BR 05 : 5 decades 1 Ω to 10 kΩ P01197403 BR 06 : 6 decades 1 Ω to 10 kΩ P01197404 BR 07 : 7 decades 1 Ω to 10 kΩ Coupling jumpers P01101892A 19 mm spacing - Ø 4 mm - 36 A Capacitance decade boxes P01199613A 0.01 to 0.1 mF P01199612A 0.1 to 1 mF P03199611A 1 to 10 mF P01197421 BC 05: 5 decades - 1 nF to 10 μF Null galvanometer P03197611A Bandwidth: 60 and 100 MHz Dial with anti-parallax mirror, accuracy ±2.5 % 2 calibres by pushbutton Ratio boxes P03197531A 7 ratios: from 1/1,000 to x 1,000, accuracy ±0.2 % for Wheatstone bridge application Measurement shunts Max. current Voltage drop HA030-1 (Class 0.5 compliant with the IEC 61010-1 standard, 600 V CAT III) 30 A 300 mV HA050 50 A 100 mV HA050-1 50 A 50 mV n IEC61010-1 -150V CAT II, 50V CAT III n Selection by rotary switch lAboRAtoRy inStRumEntS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr LaBORaTORY CALIBRATOR CX 1651 Multi-function calibrator Based on a new concept, the CX 1651 generates: n standard electrical parameters for temperature or energy applications n non-harmonic signals for testing equipment when the distortion on the input signals is non-null. It can be used to calibrate a wide variety of instruments: n Multimeters n Analogue instruments n Switchboard equipment n Current clamps n Portable calibrators n Wattmeters n Electrometers n Oscilloscopes n Thermometers n Loggers, etc. Designed for measuring instrument manufacturers seeking to calibrate their instruments, the CX 1651 is particularly accurate and stable. V A
For further details… Reference to order CX1651: 1 CX 1651 multi-function calibrator Standard state at delivery 1 multi-function calibrator delivered with 1,000 V / 20 A test cables (x 2), 1 Option 40 cable adapter (Canon 25/2 x banana cable adapter, 1 m), 1 Option 60 cable adapter (Canon 25/4 x banana cable adapter, 1 m), 1 Option 70 cable adapter (adapter for resistances on four terminals), 1 RS 232 cable, 1 power cable, 2 spare fuses, 1 test report and 1 user manual. Available accessories See pages 102 and 103 Specifications CX 1651 Voltage DC 6 ranges from 0 V to 1,000 V AC 6 ranges from 1 mV to 1,000 V Current DC 6 ranges from 1 μA to 20 A AC 6 ranges from 1 μA to 20 A Resistance (4-wire set-up) 10 ranges from 0 Ω to 50 MΩ Maximum voltage Capacitance (4-wire set-up) 9 ranges from 900 pF to 50 μF supported by the load: 8 Vpk PWM 0.1 Hz to 100 kHz Frequency (pos, neg, sym) HF (rise time 0.1 Hz to 100 kHz < 5 ns) DC Voltage from 200 mV to 240 V Current from 2 mA to 10 A Voltage from 200 mV to 240 V Power Current from 2 mA to 10 A Acquisition time Energy AC Frequency from 40 Hz to 400 Hz in energy mode Power factor –1 or +1 10 s to 1,999 s Phase from 0 to 360° Thermocouple R, S, B, J, T, E, K, N Temperature Ranges from –250 °C to +1,820 °C sensor RTD sensor Pt 1385, Pt 1392, Ni Ranges from –200 °C to +850 °C Function Range Accuracy Vdc (DC voltage) 0 - ± 12 V 0.01 % + 100 μV mVdc (DC voltage) 0 - ± 2,000 mV 0.01 % + 10 μV mAdc (DC current) 0 - ± 25 mA 0.02 % + 1 μA FREQ (Frequency) 1 Hz – 15 kHz 0.005 % R4W (Resistance) 0 - 2 kΩ 0.02 % + 100 mΩ TRTD (RTD sensors) -150 °C – +600 °C 0.1 °C TTC (TC sensors) -250 °C – +1,820 °C 0.4 - 4 °C SGS (deformation)* Depending on sensor 0.01 % + 10 μV + sensor accuracy LaBORaTORY CALIBRATOR lAboRAtoRy inStRumEntS
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr ACCESSORIES INDEX Accessories for multimeters Accessories for oscilloscopes
ACCESSORIES FOR MULTIMETERS Choosing your current clamp To choose your clamp, we advise you to follow the logic presented below: Measurement input n Measurement of DC or AC currents? (see AC or AC/DC clamps table) n Measurement of low, medium or high currents? On small wires or large cables? … only choose the families with the right shapes and dimensions Output - Connection technology n What instrument will the clamp be connected to? (see Output/Connection column to choose a clamp whose signal and connection technology are compatible) Specific features n What are your other criteria? (see the Specific Features column to check whether the clamp chosen perfectly matches your requirements) There are multiple criteria for choosing a current clamp. The approach below helps to specify your requirements and guide you naturally towards the most suitable model for your application. The CHAUVIN ARNOUX Catalogue contains a complete list of the clamps available. Specifications Accessories for multimeters: clamps AC current measurement • AC current measurement with flexible probe • AC/DC current measurement • Leakage current measurement • Process current measurement • Pages 98 99 100 101 101 Selection guide on pages 28-29 Accessories for multimeters: Connection Safety Leads and test probes ø 4 mm • 4 mm banana connection accessories • Adapters and probes • Transport and protection accessories • Fuses • Pages 102 103 102-105 106-107 107 Software: see pages 32-33 ACCESSoRiES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr ACCESSORIES FOR MULTIMETERS AC current clamps Very low current Low current Medium current Current Voltage Lead + Ø4 mm safety plugs Female sockets Ø4 mm BNC connector (coaxial) Transformation ratio (input/output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) To order MINI 01 MINI 02 MINI 05 MN12 MN08 MN09 MN14 MN89 C100 C103 C106 C107 2 to 150 A 50 mA to 100 A 5 mA to 10 A
1 A to 100 A
0.5 A to 240 A 0.5 A to 240 A 0.5 A to 240 A 0.5 A to 240 A 0.5 A to 240 A
0.1 A to 1,200 A
1,000/1 1,000/1 1 mA / 1 mV
1 A / 1 mV
1 A / 10 mV
1,000/1 1,000/1
1 A / 100 mV
1,000/1 1,000/1
0.15 AAC
10 VAC
0.1 VAC
Bandwidth (frequency in Hz)
48 Hz … 500 Hz
48 Hz … 10 Hz
40 Hz … 10 kHz
30 Hz … 10 kHz
≤ 2.5 % ≤ 1 % ≤ 3 % ≤ 2 % ≤ 1 % ≤ 1 % ≤ 1 % ≤ 1 % ≤ 2 % ≤ 0.5 % ≤ 0.5 % ≤ 0.5 % ≤ 0.5 % P01105101Z P01105102Z P01105105Z P01120405 P01120401 P01120402 P01120416 P01120415 P01120301 P01120303 P01120304 P01120305 Input Output Specific features Measurement range connections ModelSeries MINI MN C Standard state at delivery 1 clamp and 1 user manual MINI 05 C103 MN09 MN89
ACCESSORIES FOR MULTIMETERs Flexible probes for AC current Very low current Low current Medium current High current AC DC Current Voltage Lead + Ø4 mm safety plugs Female sockets Ø4 mm BNC connector (coaxial) Transformation ratio (input/output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy To order ModelSeries
- • •
- • •
- • •
- • •
- • •
- • •
3 VAC
≤ 1 % ≤ 1 % ≤ 1 % ≤ 1 % ≤ 1 % ≤ 1 % P01120660 P01120661 P01120662 P01120630 P01120631 P01120632 Input Output Specific features Measurement range connections Standard state at delivery 1 flexible current sensor delivered with 2 x 1.5 V AA / LR6 batteries, 1 user manual in 5 languages and 1 safety datasheet MA 110
0.02 A - 3A
0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3000 A 0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3,000 A 0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3,000 A 0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3,000 A 0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3,000 A
0.05 A - 3A
0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3,000 A
1 V/A
0.1 mV/A 10 Hz .. 10 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 10 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 10 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 10 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 10 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 10 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz MA110 3-30-300-3000/3 (17 cm / Ø 4.5 cm) MA110 3-30-300-3000/3 (25 cm / Ø 7 cm) MA110 3-30-300-3000/3 (35 cm / Ø 10 cm) A110 3-30-300-3000/3 (45 cm / Ø 14 cm) A110 3-30-300-3000/3 (80 cm / Ø 25 cm) A110 30-300-3000-30000/3 (120 cm / Ø 38 cm) Optional accessories Mains adapter + μUSB-B cable for MA110/ A110: PO1651023 A 110 ACCESSoRiES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr 100 ACCESSORIES FOR MULTIMETERS AC/DC CURRENT CLAMPS Very low current Low current Medium current High current AC DC Current Voltage Lead + Ø4 mm safety plugs* Transformation ratio (input/output) Automatic DC zero Bandwidth (frequency in Hz) Typical accuracy To order E6N PAC 11 PAC 20 PAC 21 0.1 to 450 mADC 0.1 to 300 mARMS 0.1 to 450 mA peak 5 mA to 2 ADC 5 mA to 1.5 ARMS 20 mA to 80 AAC/DC 0.2 to 40 AAC 0.4 to 60 ADC 0.5 to 600 ADC 0.5 to 600 AAC 0.5 to 1,000 AAC 0.5 to 1,400 ADC 0.2 to 100 AAC 0.4 to 150 ADC 0.5 to 1,000 AAC 0.5 to 1,400 ADC 1 mA / 10 mV
1 A / 1 V
4.5 VDC
3 VRMS
4.5 V peak
2 VDC
1.5 VAC
0.8 VAC/DC
1.4 VAC/DC
DC to 1.5 kHz DC to 2 kHz DC to 8 kHz DC to 10 kHz DC to 5 kHz DC to 10 kHz ≤ 1 % ≤ 2 % ≤ 4 % ≤ 1.5 % ≤ 2.5 % ≤ 2 % ≤ 1.5 % ≤ 2.5 % P01120074A P01120040A P01120068 P01120071 P01120069 Input Output Specific features Measurement range connections * Lead + electronic unit with Ø 4 mm safety plugs with 19 mm spacing for the K Series ModelSeries K E PAC 1X PAC 2X E6N PAC11 PAC20 Standard state at delivery Delivered with 9 V battery and user manual Optional accessories Mains adapter for K: P01101966 Mains adapter for E: P01101965 Mains adapter for PAC: P0110196
ACCESSORIES FOR MULTIMETERs Current clamps for specific requirements Leakage current measurement Delivered with user manual Delivered with 9 V battery and user manual * Lead + electronic unit with Ø 4 mm safety plugs with 19 mm spacing for the K Series Measurement of process current CVery low current Model Series Low current Medium current High current AC DC Current Voltage Lead + Ø4 mm safety plugs* Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Transformation ratio (input/output) BNC connector (coaxial) Automatic DC zero Bandwidth (frequency in Hz) Typical accuracy To order MN73 C173 B102 10 mA to 2.4 A 100 mA to 240 A 1 mA to 1.2 A
0.01 A to 12 A
0.1 A to 120 A
1 A to 1,200 A
500 µA to 4 A
0.5 A to 400 A
1 A / 1,000 mV
10 A / 1 V
100 A / 1 V
1000 A / 1 V
2 VAC
1 VAC
4 VAC
0.4 VAC
40 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
≤ 1 % ≤ 2 % ≤ 0.7 % ≤ 0.3 % ≤ 0.5 % ≤ 0.2 % ≤ 0.5 % ≤ 0.35 % P01120421 P01120309 P01120083 Input Output Specific features Measurement range connections 1 mA to 4.5 ADC 1 mA to 3 ARMS 1 mA to 4.5 A peak
- • 1 mA / 1 mV•
DC to 2 kHz ≤ 1% P01120067A ACCESSORIES FOR MULTIMETERS ACCESSoRiES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr 102 ACCESSORIES FOR MULTIMETERS Leads and accessories Removable test probes For CAT IV & CAT III installations Set of 2 moulded test probes Female plug Ø 4 mm 15 A- CAT IV and CAT III 1,000 V > P01295454Z For CAT II and lower installations Set of 2 moulded test probes Ø 4 mm Female plug Ø 4 mm 15 A - CAT II 300 V > P01295458Z For CAT II and lower installations Set of 2 moulded test probes Ø 2 mm Female plug Ø 4 mm 15 A - CAT II 300 V > P01295460Z Moulded measurement leads Set of 2 moulded PVC leads (R/B) Insulated straight male plug Ø 4 mm - Insulated straight male plug Ø 4 mm 15 A, 1.5 m - 1,000 V CAT IV > P01295450Z Set of 2 moulded PVC leads (R/B) Insulated straight male plug Ø 4 mm - Insulated elbowed male plug Ø 4 mm 15 A, 1.5 m > P01295451Z Set of 2 moulded silicone leads (R/B) Insulated straight male plug Ø 4 mm - Insulated straight male plug Ø 4 mm 15 A, 1.5 m - 1,000 V CAT IV > P01295452Z Set of 2 moulded silicone leads (R/B) Insulated straight male plug Ø 4 mm - Insulated elbowed male plug Ø 4 mm 15 A, 1.5 m 1,000 V CAT IV > P01295453Z Standard measurement leads Set of 2 PVC leads (R/B) Insulated straight male plug Ø 4 mm -Insulated straight male plug Ø 4 mm 15 A, 1.5 m - 600 V CAT IV / 1,000 V CAT III > P01295288Z Set of 2 PVC leads (R/B) Insulated straight male plug Ø 4 mm - Insulated elbowed male plug Ø 4 mm 15 A, 1.5 m - 600 V CAT IV / 1,000 V CAT III > P01295289Z Set of 2 PVC leads (R/B). Insulated straight male plug Ø 4 mm with rear connection - Insulated straight male plug Ø 4 mm with rear connection
20 A, 2 m - 600 V CAT III > P01295290Z
Set of 2 PVC test-probe leads (R/B) Insulated straight male plug Ø 4 mm 15 A, 1.5 m - 1,000 V CAT IV > P01295455Z Set of 2 PVC test-probe leads (R/B) Insulated elbowed male plug Ø 4 mm 15 A, PVC 1.5 m - 1,000 V CAT IV > P01295456Z Set of 2 IP2X PVC leads for multimeter Compliant with NF C 18-510 and IEC 61010- 031+A1:2008 IP2X test probe - Insulated elbowed male plug Ø 4 mm 15 A, 1.5 m - 600 V CAT IV > P01295461Z Set of 2 red/black crocodile clips
15 A - 1,000 V CAT IV
P01295457Z Set of leads and measurement accessories for electricians 2 x moulded test probes 1,000 V CAT IV - 2 red/black moulded PVC leads with straight male plug – elbowed male plug 1.5 m 1,000 V CAT IV - 2 red/black crocodile clips 1,000 V CAT IV - 2 x moulded test probes Ø 4 mm - 300 V CAT II > P01295459Z Kit with 2 PVC leads + 2 test probes Ø4 mm - Straight male plug Ø4 mm - Elbowed male plug Ø4 mm - Test probe Ø 4 mm - Female plug Ø 4 mm - CAT II 300V > P01295475Z Set of 2 red/black magnetized test probes For voltage measurement only, test probe Ø 6.6 mm – Elbowed female plug Ø 4 mm - 1,000 V CAT III / 600 V CAT IV > P01103058Z Set of 2 red/black crocodile wire grips
20 A - 1,000 V CAT III
P01102053Z Set of 2 adapters - Insulated female BNC plug – Insulated red/black male plugs Ø 4 mm with 19 mm spacing - 600 V CAT III > P01102101Z Kit of 2 PVC leads + 2 test probes Ø 2 mm - Straight male plug Ø 4 mm - Elbowed male plug Ø 4 mm - Test probe Ø 2 mm - Female plug Ø 4 mm - 300 V CAT II > P01295474Z PVC lead Insulated male BNC plug – Insulated straight male banana plugs Ø 4 mm (red/black)with rear connection - 1 m - 500 V CAT III > AG-1066Z Ø 4 mm banana connection accessories
Set of 2 thermocouple safety adapters for multimeters Female thermocouple plug - Insulated male plugs (R/B) Ø 4 mm with 19 mm spacing > P01102106Z Pt100/Pt1,000 probe adapter for multimeters Female Pt100/Pt1,000 plug - Insulated male plugs (R/B) Ø 4 mm > HX0091 Safety adapter and K-sensor temperature probe - For multimeters and clamp multimeters equipped with a temperature measurement calibre with banana inputs with 19 mm spacing - Measurement range from –50 °C to +350 °C > P01102107Z ACCESSORIES FOR MULTIMETERs Other accessories set of 2 insulation-piercing clips (r/B) 30 Vac, 60 Vdc > P01102055Z Current lead equipped with a French 2P+E power socket For inserting an ammeter in series and in total safety to measure current with a current clamp without removing the external sheath of the power supply cable > P03295509 Measurement lead for French and German 2P+E power sockets For direct measurement on a mains socket Quick implementation and reliable connections > P06239307 Set of 2 adapters Male BNC - insulated female sockets (R/B) Ø 4 mm with 19 mm spacing - 500 V CAT I, 150 V CAT III > P01101846 External charger module + 4 x AA Ni-MH batteries > HX0053 Set of 2 adapters Male BNC - Insulated male sockets (R/B) Ø 4 mm with 19 mm spacing
500 V CAT I, 150 V CAT III > P01101847
Copper-Gold-plated Beryllium contacts - Output via male plugs Ø 4 mm - Length 1.20 m - SELV > HX0064 SHT40KV High-voltage probe for multimeters Max. rated voltage: 40kVDC, 28 kVrms or 40 kVpeak Division ratio (input/output): 1 kV/1 V > P01102097 C.A 753 Measurement adapter for European 2P+E and Schuko sockets - Suitable for measurements on P (Phase), N•(Neutral) and PE (Earth) conductors in total safety - Guarantees mechanical and electrical contact with all test probes (Ø2, Ø4, IP2X, etc.) - Shows the presence of a P-N voltage (> 200 V) and indicates the position of the phase Temperature measurement ACCESSoRiES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr 104 Physical measurement K thermocouple sensors Thermocouple technology The sensor is formed by the thermocouple measurement junction at its hot point. The reading is taken at its cold junction, which requires compensation to simulate the point at 0 °C. Various materials are used to manufacture these thermocouples. The thermo-electric forces and tolerances are defined in the IEC 584 standard. IEC 584 correspondence table (extracts): temperature and voltage °C mV °C mV °C mV EIT 584 EIT 584 EIT 584 -40 1.527 50 2.023 600 24.905 0 0 100 4.096 1,000 41.276 200 8.138 1,200 48.838 Interchangeability tolerance according to NF EN 60584-2 Class 1 Class 2 +375 °C to +1,000 °C: ±0.004 x t °C +333 °C to +1,200 °C: ±0.0075 x t °C where t is the temperature in °C References to order P03652901 : SK 1 P03652902 : SK 2 P03652903 : SK 3 P03652904 : SK 4 P03652905 : SK 5 P03652906 : SK 6 P03652907 : SK 7 P03652908 : SK 8 P03652917 : SK 11 P03652918 : SK 13 P03652919 : SK 14 P03652920 : SK 15 P03652921 : SK 17 P03652922 : SK 19 P03652909: CK 1 P03652910: CK 2 P03652913: CK 3 P03652914: CK 4 Model Measurement Response Diameter Length Description range time K thermocouple sensors SK1 needle -50 to +800 °C 1 s 3 mm 15 cm For penetration into pasty, viscous products SK2 bendable -50 to +1,000 °C 2 s 2 mm 1 m Can be bent as required SK3 semi-rigid -50 to +1,000 °C 6 s 4 mm 50 cm Can be bent slightly SK4 surface 0 to +250 °C 1 s 5 mm 15 cm Adapted for measurements on small surfaces SK5 surface -50 to +500 °C 1 s 5 mm 15 cm 8 mm Ø spring tip ensuring optimum contact even if the sensor is not placed at right angles SK6 flexible -50 to +285 °C 1 s by contact 1 mm 1 m Recommended for points where access is difficult 3 s in ambient air SK7 air -50 to +250 °C 5 s 5 mm 15 cm For measurements of ambient air. Thermocouple protected by a metal sheath Ø 8.5 mm SK8 auto-grip -50 to +140 °C 10 s on stainless For pipes The thermocouple placed on a sheet of copper, at the end of a double steel pipe (Ø 12 mm) 10 mm ≤ Ø ≤ 90 mm sided Velcro ribbon, is held in contact by winding the ribbon round the pipe SK11 needle -50 to +600 °C 12 s 3 mm 13 cm For penetration into pasty, viscous products SK13 general use -50 to +1,100 °C 12 s 3 mm 30 cm All uses SK14 surface-elbowed -50 to +450 °C 8 s 6 mm 13 cm Surface temperature for difficult access. Tip Ø 15 x 30 mm SK15 surface -50 to +900 °C 2 s 8 mm 13 cm Tip Ø 8 mm with spring, ensuring optimum contact SK17 air -50 to +600 °C 3 s 6 mm 13 cm For ambient air measurements SK19 surface with magnet -50 to +200 °C 7 s 14 mm 12 mm Fixed by magnet ACCESSORIES FOR MULTIMETERS
Pt100 Ω technology The relation between the resistance and the temperature, like the tolerances, is defined in the IEC 751 European standards. 2 different technologies are used:
- platinum-wire resistors wound around an insulating support
- ceramic substrate coated with a platinum film References to order P03652712: SP 10 P03652713: SP 11 P03652714: SP 12 P03652715: SP 13 HX0091 : Banana plug / Pt100 connector adapter Tolerance class - The IEC 751 standard defines the interchangeability tolerances as follows: Tolerance class Tolerance A 0.15 + 0.0025 x [t] [t] is the absolute value of the temperature in °C IEC 751 correspondence table (extracts): temperature and resistance °C Ω °C Ω °C Ω EIT 90 EIT 90 EIT 90 200 18.52 50 119.4 400 247.09 -100 60.26 100 138.51 600 313.71 0 100 200 175.40 850 390.48 Model Measurement Response Diameter Length Tolerance Description class Pt100 platinum probes SP 10 -50 to +200 °C 6 s 5 mm Needle 13 cm B For flat surfaces. The spring ensures optimum contact, even if the sensor is not set up perpendicularly. SP 11 -100 to +600 °C 7 s 3 mm Needle 13 cm B For penetration (20 mm minimum) in pasty and viscous products. SP 12 -100 to +600 °C 5 s 5 mm Needle 13 cm B Suitable for all ambient air measurements (moving air). If the air is “stationary”, agitate the sensor. SP 13 -100 to +600 °C 7 s 3 mm Needle 13 cm B Specially designed for liquids SP 14 -40 to 450 °C 7 s 3 mm 20 cm A Sensor in stainless-steel 316L sheath for general use ACCESSORIES FOR MULTIMETERs SP 14 ACCESSoRiES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr 106 For MX Concept series: MX 21, MX 22, MX23, MX 24, MX 24B Sheath AE0237 Soft case AE0190 Hard case HX0009 Transport soft case HX0018 For ASYC II series: MX 20, MX 44, MX 5x Sheath MC0160B Handle MC0159B Hard case AE0227 Soft case AE0193 For MTX series: MTX 3281, MTX 3282, MTX 3283 Soft case HX0052 For analogue multimeters Soft case AE0216 Hard case AE0228 For ASYC IV multimeters Soft case: MTX 3290 and MTX 3291 HX0052 B Soft case: MTX 3292 and MTX 3293 HX0052C Metal cases Equipped with foam inserts and delivered with strap and keys MultiFix accessory for DMMs When used with compatible measuring instruments, soft cases, bags, etc., the MultiFix accessory can be used to transport and mount products so that they are more comfortable to use. All-terrain waterproof site cases Equipped with foam inserts P01298072 P01298004 P01298071 P01298069 P01102100Z P01298068 Dimensions References 272 x 248 x 130 mm P01298068 272 x 248 x 182 mm P01298069 Dimensions References 270 x 195 x 65 mm P01298071 320 x 255 x 75 mm P01298004 440 x 310 x 135 mm P01298072 ACCESSORIES FOR MULTIMETERS General-purpose transport and protection accessories MC 0160B MC 0160B + MC 0159B HX0052 AE 0237 MTX329X bag
ACCESSORIES FOR OSCILLOSCOPES Choosing your voltage probe To choose the probe to adapt to your oscilloscope, we advise you to follow the logic below: Measurement input n Max. AC voltage measurement and choice of installation category: CAT II or III? Attenuating probe or differential probe? n Choice of attenuation: 1/10, 1/100 or 1/1,000 or 1/20, 1/200? Bandwidth according to the oscilloscope? n Measurement input impedance Output- Connection technology n BNC or PROBIX? Specific features n What are the other criteria? Capacitance, rise time, safety, power supply, etc. There are multiple criteria for choosing a probe. The approach below helps to specify your requirements and guide you naturally towards the most suitable model for your application. Specifications Voltage probes CAT II voltage probes • High-voltage probe • CAT II 300 V voltage probes • PROBIX probes for SCOPIX • Differential probes • Pages 108 109 109 73 110-111 Current probes Measurement with AC/DC clamp • Measurement with AC clamp • Measurement with flexible AC clamp • Pages 112 112 113 Connection and protection accessories BNC • Protection and transport • Fuses • Pages 114 115 116 Software Scopix-Handscope DOX Pages 76-77 64 Choosing your current probe for oscilloscopes ACCESSoRiES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr 108 ACCESSORIES FOR OSCILLOSCOPES Electronic voltage probes HX0003, HX0004, HX0005, HX0006 & HX0108 n A family of 5 products to cover all types of requirements n Attenuation ratio of 10 or 100 (depending on the model) n Bandwidth from 150 MHz to 300 MHz n EN61010 safety from 400 V CAT II to 1,000 V CAT III (depending on the model) n Compensation range from 12 to 22 pF or from 12 to 25 pF (depending on the model) n Connection accessories are available for the probes: - HX0007: hook-type wire-grip termination - HX0008: crocodile-type wire-grip termination n Additional accessories are delivered with the HANDSCOPE HX0108 kit ISOPROBE III probe compliant with 600 V CAT III with 1/10 attenuation on a 500 MHz bandwidth + HX0107 BNC /BAN adapter References to order HX0003: Compact 10:1 probe, 150 MHz HX0004: Compact 10:1 probe, 250 MHz HX0005: Compact 10:1 probe, 450 MHz HX0006: Compact 100:1 probe, 300 MHz HX0108: Measurement kit comprising 1 compact 10:1 probe - 500 MHz 600 V CAT III, and one BNC/Banana ø 4 mm adapter (HX0107) Standard state at delivery HXxxxx: 1 probe, 1 reference lead, 1 user manual Accessories for HXOOOx HX0007: Hook-type wire-grip termination HX0008: Crocodile wire-grip termination HX0108 kit Specifications HX0003 HX0004 HX0005 HX0006 HX0108 Attenuation 1:10 1:10 1:10 1:100 1:10 Bandwidth 150 250 450 300 500 Input impedance (MΩ) 10 ±1 % 10 ±1 % 10 ±1 % 100 ±1 % 10 ±1 % Capacitance (pF) 14 14 < 14 ≤ 6 12 Rise time (ns) 1.2 ≤ 1.2 ≤ 1 < 1 0.9 EN61010-2-031 safety 400 V CAT II 1,000 V CAT II 1,000 V CAT II 1,000 V CAT II 600 V CAT III max 5 kV peak Compensation range (pF) 12 to 25 12 to 25 12 to 25 12 to 22 10 to 22 Retractable safety sleeve Grey Blue Violet Red Grey
ACCESSORIES FOR OsCILLOsCOPEs General-purpose probes HX0206, HX0210 & HX0220 High-voltage / high-frequency probe HX0027 n Design mounted on a patented ceramic support, with the elements adjusted by laser n Interchangeable spring-mounted tip n 1/1,000 probe with 30 MHz bandwidth n This 14kV high-voltage probe can be used in various sectors: - automotive inrush - radar pulse measurement - motor control - transformers - switching systems in electrical engineering and power electronics - pulsed discharge lighting equipment (Xenon lamps) - drilling systems in the oil industry - railway sector n A family of 3 products for general-purpose requirements n Attenuation with a switchable ratio of 1:1 or 10:1 n 60 MHz, 100 MHz or 200 MHz depending on the model Standard state at delivery HX0027: 1 probe, 1 "hook" measurement termination, 1 crocodile clip, 1 screwdriver for adjustment, 1 user manual, 1 hard case HX0206-HX0210-HX0220: 1 probe, 1 "hook" measurement termination, 1 crocodile measurement earth, 1 screwdriver for adjustment, 1 user manual Specifications HX0027 HX0206 HX0210 HX0220 Attenuation 1:1,000 1:1 1:10 1:1 1:10 1:1 1:10 Bandwidth 30 15 60 15 100 15 200 Input impedance (MW) 100+-1 % 1 10 1 10 1 10 Capacitance (pF) < 2.5 45 15 46 15 45 11 Rise time (ns) < 12 23 6 23 3.5 35 1.7 EN61010-2-031 safety 14 kV max 40 kV peak 300 V CAT II 300 V CAT II 300 V CAT II 300 V CAT II 300 V CAT II 300 V CAT II Compensation range (pF) 10 to 50 - 10 to 50 - 10 to 50 - 10 to 35 ACCESSORIES FOR OSCILLOSCOPES ACCESSoRiES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr 110 Differential voltage probes MX 9030, MTX 1032-B & MTX 1032-C Ideal accessories for analogue or digital oscilloscopes for viewing signals not referenced to the earth, the MTX 1032-B and MTX 1032-C are equipped with 2 differential channels. Powered by the mains supply, these probes can be used separately or hooked up to MTX Compact oscilloscopes. The MX 9030 probe is supplied in a stand-alone hand- held casing and is powered by a battery. n A family of 3 products to meet the various requirements n 1 or 2 input channels, 30 MHz or
50 MHz bandwidth
n Extra-long banana or coaxial/ banana measurement leads n Supplied in a laboratory casing or handheld casing with wrist-strap ACCESSORIES FOR OSCILLOSCOPES Use of differential probes with a Class 1 oscilloscope protected by the earth Line Neutral Earth Phase 1 Phase 2 Differential probes
MTX 112U: built-in double differential probe Standard state at delivery MX9030-Z: 1 single-channel probe with output on BNC cable, 1 standard battery installed, 1 set of PVC banana leads 1.10 m long, 1 set of 2 industrial-grade crocodile clips, 1 user manual MTX1032-B: 1 x 2-channel probe in "MTX Pack" casing, 2 BNC cables 20 cm long, 2 sets of PVC banana leads 1.10 m long, 1 European mains power cable, 1 set of accessories for mounting the probe on the oscilloscope, 1 user manual MTX1032-C: 1 x 2-channel probe in "MTX Pack" casing, 2 BNC cables 20 cm long, 1 set of 2 BNC-banana cables 2 m long, 2 crocodile wire-grips for probes, 1 European mains power cable, 1 set of accessories for mounting the probe on the oscilloscope, 1 user manual References to order MX9030-Z: 1 x 30 MHz stand-alone differential probe MTX1032-B: 2 x 30 MHz differential probe with banana inputs MTX1032-BRK: MTX1032-B rack version MTX1032-C: 2 x 50 MHz differential; probe with coaxial inputs MTX1032-CRK: MTX1032-C rack version For further details… Available accessories See pages 107 to 115 Specifications MX 9030-Z MTX 1032-B MTX 1032-C Diff. input voltage ±60 V or ±600 V ±40 V or ±400 V Max. Voltage in ±600 V common mode Attenuation / Accuracy 1/20 and 1/200 - ±3 % 1/10 and 1/100 - ±3 % Bandwidth 30 MHz 30 MHz 50 MHz Rise time 11.7 ns 11.7 ns 7 ns Output impedance 50 Ω Coaxial output voltage (max.) ± 3 V with 1 MΩ load ± 4 V with 1 MΩ load Noise level < 10 mVpp General specifications Power supply 9 V battery Mains: 230 Vac ±10 % 50/60 Hz Safety IEC 61010-1 IEC 61010-1 IEC 61010-1
600 V CAT IV 600 V CAT III 600 V CAT II
Dimensions / Weight 163 x 62 x 40 mm / 195 g (with battery) 270 x 250 x 63 mm / 1.2 kg ACCESSORIES FOR OsCILLOsCOPEsACCESSORIES FOR OSCILLOSCOPES ACCESSoRiES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr 112 Insulated current probes AC/DC current probes AC current probes Specifications HX0102 E3N PAC12 PAC22 Measurement range 3 mA to 20 Aac/dc 50 mA to 100 Aac/dc 200 mA to 600 Aac/dc 200 mA to 1,400 Aac/dc Transformation ratio 100 mV/A 100 mV/A - 10 mV/A 10 mV/A - 1 mV/A 10 mV/A - 1 mV/A Bandwidth DC to 60 kHz DC to 100 kHz DC to 10 kHz DC to 10 kHz RMS analogue output 30 mA to 20 Aac/dc 100 mVdc/A - - - Clamping diameter 11.8 mm 11.8 mm 30 mm 42 mm Output connector BNC BNC BNC BNC Cable length 2 m 2 m 2 m 2 m Dimensions 231 x 67 x 36 mm 231 x 67 x 36 mm 224 x 97 x 44 mm 236.5 x 97 x 44 mm Weight 330 g 330 g 440 g 520 g Power supply 1 x 9 V 1 x 9 V 1 x 9 V 1 x 9 V Safety CEI 61010-2-032 - 300 V CAT IV / 600 V CAT III Accessories supplied 1 x 9 V battery and user manual To order HX0102 HX0102-K* P01120043A P01120047* P01120072 P01120073 Specifications MN 60 Y7N C160 D38N Measurement range 0.1 to 60 A peak AC 1 A to 1,200 A peak 0.1 to 2,000 A peak 1 A to 5,000 A peak and 0.5 to 600 A peak AC Transformation ratio 100 mV - 10 mV/A 1 mV / A 100 mV/A – 10 mV/A – 1 mV/A – 10 mV/A – 1 mV/A 0.1 mV/A Bandwidth 40 Hz to 40 kHz 5 Hz to 10 kHz 10 Hz to 100 kHz 30 Hz to 50 kHz Clamping diameter 20 mm 30 mm 52 mm 64 mm Output connector BNC BNC BNC BNC Cable length 2 m 2 m 2 m 2 m Dimensions 135 x 51 x 30 mm 195 x 66 x 34 mm 216 x 111 x 45 mm 305 x 120 x 48 mm Weight 180 g 420 g 550 g 1,200 g IEC 61010-2-32 safety 300 V CAT IV / 600 V CAT III Accessories supplied 1 user manual To order P01120409 P01120075 P01120308 P01120057A ACCESSORIES FOR OSCILLOSCOPES
For further details… Optional accessory Mains adapter for MA200: P01102087 113 Flexible current probes Specifications MA200 MA200 MA200 Measurement range 0.5 to 45 Apeak 0.5 to 45 Apeak 5 A to 4,500 Apeak 0.5 to 450 Apeak 0.5 to 450 Apeak Transformation ratio 100 mV/A - 10 mV/A 100 mV/A - 10 mV/A 1 mV/A Bandwidth 5 Hz to 1 MHz 5 Hz to 1 MHz 5 Hz to 1 MHz Clamping diameter 45 mm 70 mm 100 mm Output connector BNC BNC BNC Cable length 2 m + 40 cm 2 m + 40 cm 2 m + 40 cm Dimensions 140 x 64 x 28 mm 140 x 64 x 28 mm 140 x 64 x 28 mm Weight 200 g 200 g 200 g Power supply 1 x 9 V 1 x 9 V 1 x 9 V IEC 61010-2-32 safety 600 V CAT IV 600 V CAT IV 600 V CAT IV 1,000 V CAT III 1,000 V CAT III 1,000 V CAT III Accessories supplied 1 x 9 V battery and 1 user manual To order P01120570 P01120571 P01120572 ACCESSORIES FOR OsCILLOsCOPEsACCESSORIES FOR OSCILLOSCOPES Y7N clamp ACCESSoRiES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr 114 Coaxial cables Coaxial cables Safety leads with 50 Ω impedance, length 1 m- IEC 61010-2-031 Cat. III 500 V, black: insulated male BNC / banana plugs with rear connection > AG1066-Z (2 p) Safety leads with 50 Ω impedance, length 1 m IEC61010-2-031 - 600 V CAT III, black > HX0106 (2 p) Earth safety leads, length 2 m, O 4 mm banana connection - IEC 61010-2-031 Cat. III 1,000 V: Female banana plug / female, yellow/green (earth) > P01295073A (5 p) Accessories Set of 2 adapters Insulated male BNC plug - insulated female plugs (R/B) Ø 4 mm with 19 mm spacing
600 V CAT III > HX0107
Insulated female BNC - Insulated plugs (RIN) ø 4 mm with 19 mm spacing - 600 V CAT III > P01102101Z Set of 2 adapters Male BNC -insulated female sockets (R/B) Ø 4 mm with 19 mm spacing
500 V CAT I, 150 V CAT III > P01101846
Male BNC - insulated male sockets (R/B) Ø 4 mm with 19 mm spacing 50 Ω BNC additional load > PA4119-50 (1 p) Rack for safety leads (1 rack) Rack for hanging 60 leads > P01101914 (1 p) Insulated T-joint IEC 61010-2-031 - 500 V CAT I 1 insulated male BNC / 2 female BNC > HA2004-Z (3 p) Insulated extension IEC 61010-2-031 - 500 V CAT I Female BNC / female BNC > HA2005 (1 p) Safety coupling jumper with 19 mm spacing - Ø 4 mm - 36 A - IEC 61010-2-031: Set of 10 black coupling jumpers > P01101892A ACCESSORIES FOR OSCILLOSCOPES
Protection and transport accessories and mechanical adaptations For oscilloscopes MTX-family bag for MTX 3240, MTX 3250, MTX 3252, MTX 3352 and MTX 3354 models. The mouse can be stored in the side pocket. > HX0024 Empty hard case for Scopix equipped with pre- cut foam inserts for stowing documents and accessories (power supply, Probix accessories, communication cables, etc.). > HX0038 ACCESSORIES FOR OsCILLOsCOPEsACCESSORIES FOR OSCILLOSCOPES Protective hands-free bag for HANDSCOPE portable oscilloscopes (OX5022 and OX5042). > HX0105 Second battery kit for SCOPIX III > HX0063 Charger unit for 12 Vdc vehicle cigarette lighter > HX0061 ACCESSoRiES
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr Fuse selection table 116 ACCESSORIES FOR OSCILLOSCOPES Product Standardized Amperage Sales concerned dimensions reference AX 501 5 x 20 3.15 A AT0069 AX 502 5 x 20 3.15 A AT0069 AX 503 5 x 20 3.15 A AT0069 MTX 3240 5 x 20 0.315 A P01297074 MTX 3250 6 x 32 10 A AT0095 MTX 3281 10 x 38 11 A P01297092 MTX 3282, MTX 3292 10 x 38 11 A P01297092 MTX 3283, MTX 3293 10 x 38 11 A P01297092 MX 1 6 x 32 10 A AT0070 MX 1 6 x 32 1.6 A AT0071 MX 2B 6 x 32 10 A AT0070 MX 2B 6 x 32 1.6 A AT0071 MX 20 8 x 32 10 A AT0055 MX 20 5 x 20 0.63 A AT0094 MX 20HD 6 x 32 10 A AT0095 MX 20HD 5 x 20 0.63 A AT0094 MX 22 6 x 32 10 A AT0095 MX 22 6 x 32 0.63 A AT0519 MX 23 6 x 32 10 A AT0095 MX 24B 6 x 32 10 A AT0095 MX 24B 6 x 32 0.63 A AT0519 MX 35D 6 x 32 10 A AT0070 MX 35D 5 x 20 3,15 A AT0053 MX 430 10 x 38 10 A P01100731 MX 430 5 x 20 0.16 A P03297508 MX 44 6 x 32 10 A AT0095 MX 44 5 x 22 0.63 A AT0518 MX 44HD 6 x 32 10 A AT0095 MX 44HD 5 x 20 0.63 A AT0518 MX 51 8 x 32 10 A AT0055 MX 51 5 x 20 0.63 A AT0094 MX 52 8 x 32 10 A AT0055 MX 52 5 x 20 0.63 A AT0094 MX 53 6 x 32 10 A AT0095 MX 53 5 x 20 0.63 A AT0518 MX 54C 6 x 32 10 A AT0095 MX 54C 5 x 20 0.63 A AT0518 MX 553, MX 5006 6 x 32 10 A AT0095 MX 556, MX 5060 6 x 32 10 A AT0095 MX 55C 6 x 32 10 A AT0095 MX 55C 5 x 20 0.63 A AT0518 MX 56C 6 x 32 10 A AT0095 MX 56C 5 x 20 0.63 A AT0518 MX 573 5 x 20 2 A AA0921 MX 573 10 x 38 10 A P01100731 MX 57EX 1 A AT0064 MX 57EX 0.5 A AT0057 MX 58HD 10 x 38 11 A P01297092 MX 58HD 5 x 20 0.63 A AT0518 MX 59HD 10 x 38 11 A P01297092 MX 59HD 5 x 20 0.63 A AT0518 OX 530 5 x 20 2.5 A AT0090 OX 803B 5 x 20 2.5 A AT0090 OX 832 5 x 20 0.315 A P01297074 OX 836B 5 x 20 2.5 A AT0090
A A110 Flexible AC current sensor 99 A130 Flexible AC current sensor 99 AmpFLEX® Flexible AC current sensor 29 AX 1360-P Laboratory power supply 90 - 92 AX 501 Laboratory power supply 90 - 91 AX 502 Laboratory power supply 90 - 91 AX 503 Laboratory power supply 90 - 91 B B102 Leakage current clamp 101 C C100 AC current clamp 98 C103 AC current clamp 98 C106 AC current clamp 29 - 98 C107 AC current clamp 29 - 98 C160 AC current probe 112 C173 Leakage current clamp 101 CX 1651 Multi-function calibrator 94 - 95 D D38N AC current probe 112 DOX 2025 Laboratory digital oscilloscope 57 - 60 - 61 DOX 2040 Laboratory digital oscilloscope 57 - 60 - 61 DOX 2100 Laboratory digital oscilloscope 57 - 60 - 61 DOX 3104 Laboratory digital oscilloscope 57 - 62 - 63 - 85 DOX 3304 Laboratory digital oscilloscope 57 - 62 - 63 - 85 E E3N Insulated AC/DC current probe 112 E6N AC/DC current clamp 28 - 29 - 100 G GX 1025 Arbitrary function generator 85 - 88 - 89 GX 1050 Arbitrary function generator 85 - 88 - 89 GX 305 Low-frequency generator 85 to 87 GX 310 Low-frequency generator 85 to 87 GX 320 Low-frequency generator 85 to 87 H HX 0059 Software for multimeters 33 HX0003 Electronic voltage probe 108 HX0004 Electronic voltage probe 108 HX0005 Electronic voltage probe 108 HX0006 Electronic voltage probe 108 HX0027 High-voltage - high-frequency probe 109 HX0082 Near-field probe 82 HX0083 Near-field probe 82 HX0102 Insulated AC/DC 112 HX0108 Electronic voltage probe 108 HX0206 General-purpose probe 109 HX0210 General-purpose probe 109 HX0220 General-purpose probe 109 K K1 Process current clamp 101 K2 AC/DC current clamp 28 - 29 - 100 M MA110 Flexible AC current clamp 99 MA130 Flexible AC current clamp 99 MA200 Flexible current clamp 115 MINI01 AC current clamp 98 MINI02 AC current clamp 28 - 29 - 98 MINI03 Current clamp 28 MINI04 Current clamp 28 MINI05 AC current clamp 28 - 29 - 98 MINI06 Current clamp 28 MINI07 Current clamp 28 MINI08 Current clamp 28 MINI09 Current clamp 28 MiniFLEX® Flexible current clamp 29 MN08 AC current clamp 29 - 98 MN09 AC current clamp 29 - 98 MN12 AC current clamp 98 MN14 Current clamp 98 MN60 AC current probe 112 Product Description Page
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr 118 INDEX BY PRODUCT MN71 Current clamp 28 - 29 MN73 Leakage current clamp 28 - 29 - 101 MN89 AC current clamp 29 - 98 MTX 1050 Spectrum analyser 80 to 82 MTX 1052 Screenless digital oscilloscope 49 to 51 - 54 - 55 MTX 1054 Screenless digital oscilloscope 49 to 51 - 54 - 55 MTX 112 Screenless digital oscilloscope 49 - 51 - 53 MTX 162 Screenless digital oscilloscope 49 - 51 -52 MTX 202 On-site digital multimeter 15 - 16 - 17 MTX 203 On-site digital multimeter 15 - 16 - 17 MTX 3290 ASYC IV digital multimeter 15 - 22 to 25 MTX 3291 ASYC IV digital multimeter 15 - 22 to 25 MTX 3292 ASYC IV digital multimeter 15 - 22 - 23 - 26 - 27 MTX 3293 ASYC IV digital multimeter 15 - 22 - 23 - 26 - 27 MTX1032-B Differential voltage probe 110 MTX1032-C Differential voltage probe 110 MX 1 On-site analogue multimeter 8 & 13 MX 125 Voltmeter 45 MX 135 Ammeter 45 MX 24 On-site digital multimeter 15 - 18- 19 MX 24B On-site digital multimeter 15 - 18- 19 MX 2B On-site digital multimeter 8 & 13 MX 350 Clamp multimeter 35 - 36 MX 355 Clamp multimeter 35 - 36 MX 406B Analogue insulation tester 42 MX 407 Insulation tester 43 MX 435D Multi-function installation tester 44 MX 5006 Benchtop multimeter 15 - 30 - 31 MX 5060 Benchtop multimeter 15 - 30 - 31 MX 57Ex Multimeter for difficult environments 15 - 20 - 21 MX 57EX-CAL Software for multimeters 33 MX 604 Insulation tester 42 MX 650 Clamp multimeter 35 - 37 MX 655 Clamp multimeter 35 - 37 MX 670 Clamp multimeter 35 - 38 MX 675 Clamp multimeter 35 - 38 MX 9030 Differential voltage probe 110 MX 98 Cos-phi meter 40 O OX 5022 On-site digital oscilloscope 65 to 67 OX 5042 On-site digital oscilloscope 65 to 67 OX 530 Analogue oscilloscope 49 - 56 OX 6062B Laboratory digital oscilloscope 57 to 59 OX 6202B Laboratory digital oscilloscope 57 to 59 OX 7042 On-site digital oscilloscope 65 - 68 - 69 - 70 OX 7062 On-site digital oscilloscope 65 - 68 - 69 - 71 OX 71 Oscilloscope analogique 49 - 56 OX 7102 On-site digital oscilloscope 65 - 68 - 69 - 71 OX 7104 On-site digital oscilloscope 65 - 68 - 69 - 70 - 71 OX 7202 On-site digital oscilloscope 65 - 68 - 69 - 71 OX 7202-BUS Bus analyser oscilloscope 72 OX 7204 On-site digital oscilloscope 65 - 68 - 69 - 71 OX 7204-BUS Bus analyser oscilloscope 72 OX 803B Analogue oscilloscope 49 - 56 Oxi 6204 Laboratory digital oscilloscope 57 to 59 P PAC11 Current clamp 28 - 29 PAC12 Insulated AC/DC current probe 112 PAC20 Current clamp 28 - 29 PAC22 Insulated AC/DC current probe 112 PROBIX Accessories for SCOPIX oscilloscopes 73 - 74 Pt100 Platinum probe 105 PX 110 Wattmeter 39 PX 120 Wattmeter 39 S SCOPENET Software for oscilloscopes 77 SK K-thermocouple sensors 104 SX METRO Software for oscilloscopes 76 SX-ASYC2C/B Software for multimeters 33 SX-DMM Software for multimeters 32 T TCX 01 SMD / Surface Mounted Device tester 8 & 9 TX 01 LED voltage tester 8 & 12 V VIRTUAL PRINTER Software for oscilloscopes 76 VX 0003 LF electric field tester 8 – 10 - 11 VX 0100 LF electric field tester 8 – 10 – 11 Y Y7N AC current probe 112 Product Description Page
A AC current clamp 98 AC current probes 112 AC/DC current clamps 100 AC/DC current probes 112 Accessories for multimeters 97 to 107 Accessories for oscilloscopes 107 to 116 Acquisition software 32 to 34 Analogue ammeter 40 Analogue multimeter 8, 13 Analogue oscilloscope 46 - 56 Analogue voltmeter 40 Arbitrary function generators 84, 85, 88, 89 C Coaxial accessories 114 Component testers 8, 9 D DDS function generators 84 to 89 Didascope training oscilloscope 48 to 53 Differential voltage probes 110, 111 Digital oscilloscope 47 to 55 - 57 to 75 E Earth (3P) 41 to 45 Earth loop 41 to 45 Electric field tester 8, 10, 11 F Field bus oscilloscope 72 Field bus 72 Flexible probes for AC current 99 Fuses 116 G General-purpose probe 109 Graphical digital multimeter 14, 15, 26, 27 H High-voltage / high-frequency probe 109 I Insulation tester 41 to 43 Insulation 41 to 43 K K thermocouple 104 L Laboratory multimeter 15, 30, 31 Laboratory oscilloscope 60 to 63 Leads 102, 103 Leakage current clamp 101 Lighting-arrester tester 42 M Metrology software 33 MTX family bag 106 Multi-function calibrator 94, 95 Multi-function installation tester 44 Multi-function oscilloscope 65 to 72 Clamp multimeter 35 to 38 Multimeter for difficult environments 15, 20, 21 N Near-field probe 82 O On-site digital multimeter 14 to 26 On-site oscilloscope 65 to 75 P PROBIX system 73, 74 Process current clamp 101 Programmable power supply 90, 92 Pt 100 105 R RCD testing 41 to 43 S SCOPIX bag 115 SCOPIX equipped case 115 Screenless oscilloscope 49 to 55 Shunt 93 Software for oscilloscopes 76, 77 Spectrum analyser 78 to 82 T Testing and electrical safety 41 to 44 Training box 93 Training oscilloscope 49 to 53 Transport accessories 106, 115 V Variable power supplies 90, 91 Voltage probes 107 to 111 Voltage tester 8, 12 W Wattmeter 39 INDEX BY FUNCTION Product Page Product Page
Detailed product brochures can be downloaded free of charge from www.metrix.fr www.metrix.fr 120 INDEX BY REFERENCE A AE0193 AE0216 AE0227 AE0228 AE0237 AG1066-Z AX0501A AX0502A AX0503A AX1360-P C CX1651 D DOX2025 DOX2040 DOX2100 DOX3104 DOX3304 E Soft case AE0190 G GX1025 GX1050 GX305 GX310 GX310-P GX320 GX320-E H HA030-1 HA050 HA050-1 HA2004-Z HA2005 HX0003 HX0004 HX0005 HX0006 HX0007 HX0008 HX0009 HX0010 HX0011 HX0012 HX0013 HX0018 HX0021 HX0024 HX0027 HX0028 HX0029 HX0030B HX0031 HX0032 HX0033 HX0034 HX0035B HX0036 HX0038 HX0050 HX0051B HX0052 HX0052B HX0052C HX0053 HX0055 HX0056-Z HX0057 HX0059 HX0064 HX0071 HX0072 HX0073 HX0077 HX0082 HX0083 HX0091 HX0092 HX0093 HX0094 HX0095 HX0096 HX0102 HX0106 HX0107 HX0108 HX0112 HX0130 HX0190 HX0191 HX0206 HX0210 HX0220 HX2002 L LX1600-PC M MC0159B MC0160B MTX1032-B MTX1032-BRK MTX1032-C MTX1032-CRK MTX1050-PC MTX1052B-PC MTX1052B-RK MTX1052BW-PC MTX1052CW-PC MTX1054B-PC MTX1054B-RK MTX1054BW-PC MTX1054CW-PC MTX112U MTX162UE MTX162UEW MTX202-Z MTX203-Z MTX2022W-P MTX2024W-P MTX3290 MTX3291 MTX3292 MTX3292-BT MTX3293 MTX3293-BT MX0001-T MX0002B MX0002BT MX0024B-CL MX0024B-CZ MX0024-CG MX0024-CL MX0057CX MX0350-Z MX0355-Z MX0407 MX0435D MX0604 MX0650-Z MX0655-Z MX0670 MX0675 MX098 MX1 MX125 MX135 MX406B MX5006 MX5060 MX57EX-CAL MX9030-Z O OX7204-BUS OX0530 OX0530-S OX0803B OX0830BS OX5022-C OX5022-CK OX5042-C OX5042-CK OX6062B-CFG OX6062B-CSD OX6062B-CSDO OX6062B-MSD OX6202B-CFG OX6202B-CSD OX6202B-CSDO OXi6204 OX7202-BUS OX7042-CSD OX7042-MSD OX7042P-CSDK OX7062-CSD OX71 OX7102-CSD OX7104-CSD OX7104-CSD OX7104-CSDO OX7104P-CSDK OX7202-CSD OX7204-BUS OX7204-CSD OX7204-CSDO P P01101846 P01101846 P01101847 P01101847 P01101892A P01101892A P01101914 P01101965 P01101966 P01101967 P01101968 P01102019 P01102021 P01102034 P01102053Z P01102055Z P01102082 P01102084 P01102084A P01102086 P01102087 P01102101Z P01102101Z P01102106Z P01102107Z P01105101Z P01105101Z P01105102Z P01105105Z P01120040A P01120043A P01120047* P01120057A P01120067A P01120068 P01120069 P01120071 P01120072 P01120073 P01120074A P01120075 P01120083 P01120301 P01120303 P01120304 Reference Page Reference Page Reference Page 106 106 106 106 106 102 106 114 114 108 108 108 108 108 108 108 106 102 111 109 111 111 103 103 108 109 109 109 106 106 110 110 110 110 110 110 110 110 110 109 110 108 108 108 108 108 108
S SX-ACQ.V2 SX-ASYC2C/B SX-ASYC2HD SX-DMM2 SX-DMMBT/B SX-DMMK2 SX-PROG.1 T TX0001-Z TX001-Z V VX0003 VX0100 Reference Page Reference Page Reference Page 108 108 109 109 109 110 102 102 102 102 102 102 102 102 102 107 107 107 107 107 105 105 105 105 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 110 10, 11
Tel.: 03 20 55 96 41 - Fax: 03 20 06 33 61 agence.lille@chauvin-arnoux.fr LYON Tel.: 04 72 65 77 60 - Fax: 04 78 03 15 39 agence.lyon@chauvin-arnoux.fr NANCY Tel.: 03 83 92 19 21 - Fax: 03 83 90 32 11 agence.nancy@chauvin-arnoux.fr NANTES Tel.: 02 40 84 01 16 - Fax: 02 40 75 35 55 agence.nantes@chauvin-arnoux.fr PARIS Tel.: 01 44 85 45 75 - Fax: 01 46 27 07 48 agence.paris@chauvin-arnoux.fr TOULOUSE Tel.: 05 62 74 50 30 - Fax: 05 61 71 45 06 agence.toulouse@chauvin-arnoux.fr GERMANY CHAUVIN ARNOUX GMBH Ohmstraße 1
77694 KEHL / RHEIN
Tel.: +49 7851 99 26-0 - Fax: +49 7851 99 26-60 info@chauvin-arnoux.de www.chauvin-arnoux.de AUSTRIA CHAUVIN ARNOUX GES.M.B.H Slamastrasse 29/2/4
1230 WIEN
Tel.: +43 1 61 61 9 61 - Fax: +43 1 61 61 9 61-61 vie-office@chauvin-arnoux.at www.chauvin-arnoux.at CHINA SHANGHAI PU-JIANG ENERDIS INSTRUMENTS CO. LTD N° 381 Xiang De Road
3 Floor, Building 1
200081 SHANGHAI
Tel.: +86 21 65 21 51 96 - Fax: +86 21 65 21 61 07 info@chauvin-arnoux.com.cn SPAIN CHAUVIN ARNOUX IBÉRICA SA C/ Roger de Flor N°293 1a Planta
08025 BARCELONA
Tel.: +34 902 20 22 26 - Fax: +34 934 59 14 43 info@chauvin-arnoux.es www.chauvin-arnoux.es ITALY AMRA SPA Via Sant’Ambrogio, 23
20846 MACHERIO (MB)
Tel.: +39 039 245 75 45 - Fax: +39 039 481 561 info@amra-chauvin-arnoux.it www.chauvin-arnoux.it MIDDLE EAST CHAUVIN ARNOUX MIDDLE EAST PO Box 60-154 1241 2020 JAL EL DIB (Beyrouth) - LIBAN Tel.: +961 1 890 425 - Fax: +961 1 890 424 camie@chauvin-arnoux.com www.chauvin-arnoux.com UNITED KINGDOM CHAUVIN ARNOUX LTD Unit 1 Nelson Ct, Flagship Sq Shaw Cross Business Pk, Dewsbury West Yorkshire - WF12 7TH Tel.: +44 1924 460 494 - Fax: +44 1924 455 328 info@chauvin-arnoux.co.uk www.chauvin-arnoux.com SCANDINAVIA CA MÄTSYS TEM AB Sjöflygvägen 35 SE-183 62 TABY Tel.: +46 8 50 52 68 00 - Fax: +46 8 50 52 68 10 info@camatsystem.com www.camatsystem.com SwITZERLAND CHAUVIN ARNOUX AG Moosacherstrasse 15
8804 AU / ZH
Tel.: +41 44 727 75 55 - Fax: +41 44 727 75 56 info@chauvin-arnoux.ch www.chauvin-arnoux.ch USA CHAUVIN ARNOUX INC d.b.a AEMC Instruments 200 Foxborough Blvd. Foxborough - MA 02035 Tel.: +1 (508) 698-2115 - Fax: +1 (508) 698-2118 sales@aemc.com www.aemc.com 10 subsidiaries spread across the world 190, rue Championnet - 75876 PARIS Cedex 18 - FRANCE Tel.: +33 1 44 85 44 38 - Fax: +33 1 46 27 95 59 export@chauvin-arnoux.fr - www.chauvin-arnoux.fr A STRUCTURE BASED ON LOCAL AGENCIES IN FRANCE INTERNATIONAL Metrix is a brand of Chauvin Arnoux 190, rue Championnet - 75876 PARIS Cedex 18 - FRANCE info@metrix.fr - www.metrix.fr ENERDIS 16, rue Georges Besse - Silic 44
92182 ANTONY Cedex - FrANCe
Tel.: +33 1 75 60 10 30 Fax: +33 1 46 66 62 54 info@enerdis.fr - www.enerdis.fr PYROCONTROLE 6 bis, av du Docteur Schweitzer
69881 MeYZIeU Cedex - FrANCe
Tel.: +33 4 72 14 15 40 Fax: +33 4 72 14 15 41 info@pyrocontrole.com www.pyrocontrole.com MÉTROLOGIE & CONTRÔLES RÉGLEMENTAIRES MANUMESURE 248, av des Grésillons
92600 ASNIÈreS sur SeINe - FrANCe
Tel.: +33 1 75 61 01 90 Fax: +33 1 47 33 28 02 info@manumesure.fr www.manumesure.fr GBGB 906 211 117 - Ed.3 - Non-contractual document.