2015-6-5 1 © 2015 TOSHIBA Corporation TOSHIBA CMOS Integrated Circuit Silicon Monolithic TC7734FTG Power Management System IC 1. DESCRIPTION TC7734FTG is a complete power supply solution for portable devices that include 4 DCDC Buck Converters, 3 LDOs, 2 -ch LED Driver and built -in Switching Charger function. Most of the outputs can be controlled by I2C bus for various programmable settings. 2. FEATURES

  • Operating voltage: 3.4 V to 5.5 V
  • 4 ch DCDC converter (DCDC1 to DCDC4)  Synchronous Current Mode Buck Converters  DCDC1-4 Optional 2-Phase Switching Reduces Input Peak Current  Built-in compensation circuit: DCDC1 to DCDC4
  • 3 ch LDO(LDO1 to LDO3)
  • LED Driver  Built-in Current Mode DCDC Boost Converter  2-Ch Constant Current LED Driver  Sink Current: up to 80 mA/ch with LED voltage up to 20 V  Output Current Accuracy: +/- 5% (ILED = 20 mA)  LED1 and LED2 Regulation Voltage: 0.4 V  PWM dimming, I2C Controlled 32 steps with 195Hz fixed dimming frequency  LED Driver Protection Circuit  Over Voltage Detection (OVD)  Output Open Detection (OOD)  Output Short Detection (OSD)
  • Battery Charger Function  USB Host and USB Charger Adaptor Detections for Optimum Charge Current for SDP, CDP, DCP and Other)  DCIN Input Over Voltage Protection (OVP): 5.8 V (typ.) * Maximum voltage of DCIN terminal is defined by 6 V.  Power Path Function  1.5 A Switching Charger with Built-in Power MOSFETs Output Descriptions: Output Adj Vout (V) Step (V) Default (V) Default Options (V) 1 Iout (A) Control DCDC4 1.5 - 3.3 - (1.8) R_ext 500 mA R_ext 1.7, 1.8, 1.9 300 mA I2C 2.5, 2.8 350 mA I2C LDO3 1.5 - 3.3 - (1.8) R_ext 120 mA R_ext Output Adj PWM Iout Vout (V) Default Iout fPWM (Hz) Control LEDD 32 steps 80 mA x2 20 20 mA x 2 195 I2C
  • I2C Control for Various Parameters
  • 1MHz Switching Frequencies DCDC1 to DCDC4
  • 1MHz Switching Frequencies LED Driver, and Switching Charger
  • PFM/PWM Operation for Wide Range of Load Current
  • Built-in Soft start Circuit
  • Programmable Power Sequence
  • Interrupt for Event Notifications
  • Power-good (PG) Notification
  • DCDC and LDO Over Current Limit Circuits (OCL)
  • Global Protection: Thermal Shutdown (TSD), VDD Under Voltage Lock Out (VUVLO), DCIN Under Voltage Lock Out (DUVLO)
  • Register Password Protection
  • Package: P-VQFN64-0909-0.50-001 9 mm × 9 mm × 0.7 mm (0.5 mm pin pitch)
  • Application: Tablet PC, Portable Devices Note 1: PFM does not apply to DCDC3 Weight: 0.192 g (typ.) P-VQFN64-0909-0.50-001

2015-6-5 2 © 2015 TOSHIBA Corporation 3. Block Diagram, Application circuit Figure: 1 Block Diagram and Application Circuit (Note)

  • Some of the functional blocks, circuits, or constants in the block diagram may be omitted or simplified for explanatory purposes. The application circuits shown in this document are provided for reference purposes only. Thorough evaluation is required at the mass-production design stage. Toshiba does not grant any license to any industrial property rights by providing these examples of application circuits.
  • GND wiring: We recommend that a heat sink be grounded at any parts, and the board and output pins be grounded at only one contact point. Take the heat dissipation into consideration when designing the board.
  • Utmost care is necessary in the design of the each output lines, each VDD lines and each GND lines since IC may be destroyed due to short-circuit between outputs, to supply, or to ground.
  • Especially for those pins that are connected to power supply and get a large current flow (such as each VDDs, Each LXs, VBAT, VSYS, MID, and each GNDs), they should be properly wired; otherwise troubles including destruction may occur to this IC.
  • If the logic input pins (such as eFuse, VREF, TEST1, TEST2 ) are not wired properly, malfunction that would destroy the IC may occur due to a large current exceeding the absolute maximum ratings. Care should be taken in the design of board layouts and implementation of the IC. LDO3 AC Adaptor USB Power 50kΩ 5kΩ 1000pF 100kΩ 100kΩ 4.7µF VREG VUVLO TSD VDD VREF 1.0µF C5 1.0µF SGND1 OVP Protection ControlPB ControlPB System Control Sequence Control I2C Control SDA SCL PGOOD Control PGOOD INT VSYS DCDC3 10kΩ 10kΩ 10kΩ DCDC3 10kΩ OSC (2MHz) Divider (1MHz) LX1 VDD1 VREF 4.7µF VSYS 10µF 10µF 10µF 2.2µH1.0V Alive/1.0V Core=1.0V OSC (1MHz) DCDC1 PGOOD OCL DCDC1 DC : 1.5A(Typ)/2.0A(MAX) AC : 3.5A(MAX) LX2 VDD2 VREF C10 4.7µF VSYS C11 10µF 2.2µH 1.35V DDR=1.35V OSC (1MHz) DCDC2 PGOOD OCL DCDC2 DC : 1.0A(Typ)/1.2A(MAX) AC : 1.5A(MAX) FB1 FB2 LX3 VDD3 VREF C12 4.7µF VSYS C13 10µF 2.2µH3.3V Alive/3.3V Logic=3.3V OSC (1MHz) DCDC3 PGOOD OCL DCDC3 DC : 0.8A(Typ)/0.96A(MAX) AC : 1.5A(MAX) FB3 LX4 VDD4 VREF C14 4.7µF VSYS C15 10µF 2.2µH1.8V Alive/1.8VSYS=1.8V OSC (1MHz) DCDC4 PGOOD OCL DCDC4 DC : 0.5A(Typ)/0.6A(MAX) AC : 1.0A(MAX) FB4 56kΩ R10 113kΩ OUT7 VDD7 VREFC16 1.0µF VSYS C17 4.7µF 1.8V Camera = 1.8V LDO1 PGOOD OCL LDO1 DC : 300mA(Min) Discharge Discharge Discharge Discharge Discharge 2.2µF DCIN MID Power Path Control Active Discharge Power Path VSYS VBAT LX1 VDD1 DCIN VSYS VSYS VBAT VBAT Charger Control OSC (1MHz) Temperature Detector CC CV LX6 CS VS SGND2 SCTL DP DM TH_REF TH CHG_STAT Charger (1.5A) 2D+ 2D− S OE R19 68mΩ Battery C24 10µF C25 4.7µF R17 300Ω @10mA,VSYS=5V C26 4.7µF VSYS 1D+ 1D− R16 100kΩ LEDD_EN SW C23 4.7µF C22 4.7µF VSYS SW Control 0.4V ON/OFF OVD OOD OSD Current Control1 Current Control2 I2C Unused Channel PWM Dimming Current Setting R14 300kΩ R15 13kΩ 2.2µH 22µH FBLED LED1 LED2 80mA(MAX) 80mA(MAX) R13 91kΩ@20mAISET OSC (1MHz) LED Driver OUT8 VREF C19 4.7µF 2.8VSYS/2.8V Camera = 2.8V LDO2 PGOOD OCL LDO2 DC : 350mA(Min) Discharge FB9 R11 82kΩ R12 160kΩ OUT9 VDD9 VREF C20 1.0µF VBAT C21 4.7µF RTC = 1.8V LDO3 DC : 120mA(Min) Discharge ILED (mA) = 1.24(V) × 1487 ÷ (RISET (kΩ) + 1.19 (kA)) TEST2 EP eFuse TEST1 DUVLO OVT TH1 R18 47kΩ ZD1 Tr1 PB1 SD1 LED1 LDO2 VDD4 PGND5 PGND6PGND1 PGND1 PGND2 PGND3 PGND4 VDD7 LDO2 LDO2 EXT_EN POR TC7USB40MU Around 0.1mA15kΩ 36kΩ

2015-6-5 3 © 2015 TOSHIBA Corporation 4. Pin Layout (Top View) Figure: 2 Pin Layout EP (Internally Connected to PGNDn) PGND6 LX6 CS LX1 LX1 VDD1 VDD1 FB1 SGND2 PGND1 PGND1 VS PGOOD INT VDD eFuse VDD2 LX2 FB2 FB3 PGND3 LX3 VDD3 VDD4 LX4 PGND4 FB4 VREF PGND2 TEST1 TEST2 SGND1 LEDD_EN FB9 TH TH_REF FBLED VDD9 OUT9 OUT8 EXT_EN VDD7 OUT7 ISET PGND5 LED1 LED2 SW VBAT VSYS CHG_STAT VBAT VBAT DCIN VSYS VSYS DCIN MID PB SCTL DP SDA DM SCL

2015-6-5 4 © 2015 TOSHIBA Corporation 5. Pin Description Table: 1 Pin Description Pin No. Name I/O Functions

1 LX6 O Switching Output Terminal for Battery Charger

2 PGND6 P Power GND Terminal for Battery charger

3 CS I Current sense(+) input Terminal

4 VS I Voltage sense input Terminal

5 SGND2 I Signal GND Terminal for small signal

6 PGND1 P Power GND Terminal for DCDC1

7 PGND1 P Power GND Terminal for DCDC1

8 LX1 O Switching Output Terminal for DCDC1

9 LX1 O Switching Output Terminal for DCDC1

10 VDD1 P VDD Terminal for DCDC1

11 VDD1 P VDD Terminal for DCDC1

12 FB1 I Feedback Terminal for DCDC1

13 PGOOD O

Power-good signal output Terminal (Open-drain). Pulled low when any of the power rails are out of regulation. Behavior can be reset in register.

14 INT O Interrupt signal output Terminal, Open Drain, external R pull up

needed.

15 VDD P VDD Terminal for IC internal bias

TEST terminal for cutting eFuse This terminal should connect to VDD terminal.

17 VREF O Internal reference voltage output terminal

18 FB2 I Feedback Terminal for DCDC2

19 VDD2 P VDD Terminal for DCDC2

20 LX2 O Switching Output Terminal for DCDC2

21 PGND2 P Power GND Terminal for DCDC2

22 FB3 I Feedback Terminal for DCDC3

23 PGND3 P Power GND Terminal for DCDC3

24 LX3 O Switching Output Terminal for DCDC3

25 VDD3 P VDD Terminal for DCDC3

26 VDD4 P VDD Terminal for DCDC4

27 LX4 O Switching Output Terminal for DCDC4

28 PGND4 P Power GND Terminal for DCDC4

29 FB4 I Feedback Terminal for DCDC4

30 SGND1 S Signal GND Terminal for small signal

31 TEST1 I TEST terminal1. Cannot be used. Connect to SGND 32 TEST2 I/O TEST terminal2. Cannot be used. No connect terminal

33 SW O LED Driver Switch terminal

2015-6-5 5 © 2015 TOSHIBA Corporation

34 PGND5 P Power GND Terminal for LED driver

35 ISET O LED current adjustment pin. Connect a resistor (RISET) to AGND

36 LED1 O Channel 1 constant current sink terminal to drive LEDs

37 LED2 O Channel 2 constant current sink terminal to drive LEDs

38 FBLED I Overvoltage threshold detect terminal for LED

39 OUT7 O Output Terminal for LDO1

40 VDD7 P VDD Terminal for LDO1 and LDO2

41 EXT_EN O Enable for external DCDC that power up sequence follows DCDC1

and turn off sequence follows DCDC2

42 OUT8 O Output Terminal for LDO2

43 OUT9 O Output Terminal for LDO3

44 VDD9 P VDD Terminal for LDO3

45 FB9 I Feedback Terminal for LDO3

46 LEDD_EN I LED Driver Enable Terminal

47 TH_REF I Battery thermistor sense input Terminal

48 TH I Battery thermistor input Terminal

49 SDA I/O I2C-DATA Terminal

50 SCL I I2C-CLK Terminal

51 DM I/O I/O pin(-) for USB power source detection

52 DP I/O I/O pin(+) for USB power source detection

53 SCTL O Open drain terminal for USB BUS control

54 PB I Push Button Switch Terminal with internal debounce circuit

55 VBAT P Battery+ Terminal

56 VBAT P Battery+ Terminal

57 VBAT P Battery+ Terminal

58 CHG_STAT O Open drain output terminal for charge status monitoring

59 VSYS O Output Terminal for System

60 VSYS O Output Terminal for System

61 VSYS O Output Terminal for System

62 MID O

Power Path Charger Mid Point Connection. Place a 2.2 uF Cap. to PGND for proper operation Please take extra care while tracing the layout of the MID terminal to avoid shortage across GND. If such shortage occurs, IC may be permanently damaged. 63 DCIN P Power supply input Terminal . This terminal should connect power supply form AC adopter or USB power. 64 DCIN P Power supply input Terminal . This terminal should connect power supply form AC adopter or USB power. EP - P Power GND Terminal Notes: I=Input, O=Output, P=Power.

2015-6-5 6 © 2015 TOSHIBA Corporation 6. I/O Equivalent Pin Circuits LX6 Terminal Name Equivalent CircuitEquivalent Circuit CS Terminal Name PGND MID SGND DCIN 3CS SGND DCIN LX6 VS LX1 4VS SGND SGND DCIN SGND LX1 LX1 VDD1 PGND VDD FB1 PGOOD 12FB1 SGND VDD SGNDPGND VDD 13PGOOD VDD SGND SGND INT VREFINT 14 VDD SGND SGND 17VREF SGND VDD SGND LOGIC

2015-6-5 7 © 2015 TOSHIBA Corporation FB2 Terminal Name Equivalent CircuitEquivalent Circuit LX2 Terminal Name FB3 LX3 LX4 FB4 TEST1 TEST2 18FB2 SGND VDD SGNDPGND VDD 22FB3 SGND VDD SGNDPGND VDD 27LX4 VDD4 VDD PGND PGND 31TEST1 SGND VDD SGND VDD 20LX2 PGND VDD2 VDD 24LX3 PGND VDD3 VDD 29FB4 SGND VDD VDD 32TEST2 SGND VDD

2015-6-5 8 © 2015 TOSHIBA Corporation SW Terminal Name Equivalent CircuitEquivalent Circuit ISET Terminal Name LED1 LED2 FBLED OUT7 EXT_EN OUT8 33SW PGND PGND 35ISET SGND VDD 36LED1 PGND PGND 37LED2 PGND PGND 38FBLED SGND VDD VDD SGND VDD SGND 39OUT7 PGNDSGND VDD VDD7 41EXT_EN SGND VDD9 SGND OUT9 42OUT8 PGNDSGND VDD VDD7

2015-6-5 9 © 2015 TOSHIBA Corporation OUT9 Terminal Name Equivalent CircuitEquivalent Circuit FB9 Terminal Name LEDD_EN TH_REF TH SDA SCL DM 43OUT9 PGND VDD9 VDD9 45FB9 SGND LD_SEL LEDD_EN 46 SGND VDD SGND VDD SGND 47TH_REF LDSEL SGND 48TH SGND LD_SEL SGND PGND SGND VDD SCL 50 SGND SGND 49SDA SGND VDD SGND SGND SGND 51DM SGND DCIN SGND DCIN

2015-6-5 10 © 2015 TOSHIBA Corporation DP Terminal Name Equivalent CircuitEquivalent Circuit SCTL Terminal Name PB VBAT DCIN CHG_STAT VSYS MID 52DP SGND DCIN SGND DCIN 53SCTL VDD SGND SGND 54PB LD_SEL SGND SGND LD_SEL SGND VBAT VBAT VBAT PGNDSGND VSYS SGND PGND DISCHG 64DCIN DCIN LD_SEL 58CHG_STAT SGND DCIN SGND VSYS VSYS VSYS SGND VBAT PGNDSGND SGND MID 62MID PGNDSGND DCIN VSYS SGND

2015-6-5 11 © 2015 TOSHIBA Corporation 7. State Diagram Figure: 3 State diagram HW_STANDBY state change condition From DELAY1,2 from RTC DELAY, OFF Move to ACTIVE PB (↓) || ACTIVE bit (↑) (DCIN (↑) (1) && !STANDBY_CHG(2)) || PB (↓) || ACTIVE bit (↑) STANDBY_CHG (CDP or SDP) (Detect USB SDP && SDP_CHG_EN = ‘1’ ) || (Detect USB CDP && CDP_CHG_EN = ‘1’). (Detect USB SDP && SDP_CHG_EN = ‘1’ && VBAT < VSYS_LOW) || (Detect USB Power OFF HW STANDBY Note(5) ACTIVE DELAY 3 VBAT > VBAT_DET(7) || DCIN > DUVLO(1) NOTES: TSD = Thermal Shutdown Function PB = Push Button Input ULVO has priority over TSD LEDD boost faults disable LEDD driver only but not power rails || OR && AND PB (↓) pushed bottom DCDCx = OFF LDO1,2 = OFF LDO3 = ON LEDD = OFF PPATH = ON CHARGER = ON I2C = YES(8) PGOOD = LOW Registers → default except DCIN input current limit always set based on USB Detection Type NOTE: USB Detection always done upon entering this state or when DCIN applied DCDCx = ON LDO1,2 = ON LDO3 = ON LEDD = ON PPATH = ON CHARGER = ON I2C = YES PGOOD = HIGH (depend on power rails) Registers → default except DCIN input current limit and USB Detected Type OFF bit (↑) OFF DCDCx = OFF LDO1,2 = OFF LDO3 = ON LEDD = OFF PPATH = OFF(4) CHARGER = OFF I2C = NO PGOOD = LOW Registers → default ANY STATE VPOR(3)<VSYS <VUVLO DCDCx = OFF LDO1,2 = OFF LDO3 = ON LEDD = OFF PPATH = OFF CHARGER = OFF I2C = NO PGOOD = LOW Registers → default DELAY 2 VSYS < VSYS_LOWDCDCx = OFF LDO1,2 = OFF LDO3 = ON LEDD = OFF PPATH = ON CHARGER = ON I2C = YES PGOOD = LOW Registers → default DELAY 1 TSD || PGOOD fault || PB (↓) ≥ 8s DCDCx = OFF LDO1,2 = OFF LDO3 = ON LEDD = OFF PPATH = OFF(4) CHARGER = OFF I2C = NO PGOOD = LOW Registers → default VBAT && DCIN < VPOR(3) SW STANDBY Note (6) (DCIN > DUVLO(1) && !STANDBY_CHG(2)) DCDCx = OFF LDO1,2 = OFF LDO3 = ON LEDD = OFF PPATH = ON CHARGER = ON I2C = YES PGOOD = LOW Registers → No change from Active State settings STANDBY bit (↑) DCIN > DUVLO && STANDBY_CHG(2) (DCIN > DUVLO(1) && !STANDBY_CHG(2)) || PB (↓) || ACTIVE bit (↑)STANDBY_CHG(2) PB (↓)DCIN > DUVLO(1) RTC DELAY DCDCx = OFF LDO1,2 = OFF LDO3 = ON LEDD = OFF PPATH = ON CHARGER = ON I2C = YES PGOOD = LOW Registers → default Wait 1s ANY STATE Wait 1s Wait 1s Wait 1s Footnotes: (1) At this event, PMIC shall detect USB type (DCP, SDP, CDP,Other), and set DCIN input current limit accordingly. (2) STANDBY_CHG = (((Detect USB DCP || Detect Non-Compliant USB) && DCP_CHG_EN = ‘1’) || (Detect USB SDP && SDP_CHG_EN = ‘1’ && VBAT < VSYS_LOW) || (Detect USB CDP && CDP_CHG_EN = ‘1’ && VBAT < VSYS_LOW)). (3) VPOR(Power On Reset) is defined by design. Target voltage: 2.4V (4) Battery voltage always supplies the system by Q3 in P.19 (From VBAT to VSYS) (5) HW STANDBY state: Always detect USB Type (DCP, SDP, CDP,Other) when state change from OFF state and RTC delay by “DCIN > DUVLO”. (6) SW STANDBY state: Only detect USB Type (DCP, SDP, CDP,Other) on “DCIN > DUVLO” timing. (7) VBAT_DET is defined by design. Target voltage: 2.6V (8) I2C cannot accept in beginning of ACTIVE state (around 40µs)

2015-6-5 12 © 2015 TOSHIBA Corporation 8. DCDC converter and LDO Functions 8.1. Operation description DCDC converter and LDO Functions are determined by the internal registers set by I2C bus. ACTIVE mode can be full mode where all outputs are turned on or selective rails can be turned on. Value of the register can be changed by writing data to the register. 8.2. Voltage Supply Terminal (VDD) VDD is a power supply for DCDCn converter / LDO and for internal control circuit of TC7734FTG. VDD operation range is 3.4V to 5.5V. It can be connected to VSYS for power. 8.3. DCDC Converter (DCDC1 to DCDC3) Default Options They are synchronous DCDCn Buck Converter of PFM/PWM type. Switching frequency is fixed of 1MHz (typ.). Select of the default options of DCDC1-3 are set by fuse options. For different defaults needed, please contact to Toshiba. DCDC1 default options are 0.9 - 1.4 V@50 mV and the default is 1.0 V DCDC2 default options are 1.05 - 1.95 V@150 mV and the default is 1.35 V DCDC3 default options are 2.7 – 3.4 V@100 mV and the default is 3.3 V 8.4. LDO1 and LDO2 Default Options Select of the default options of LDO1,2 are set by fuse options. For different defaults needed, please contact Toshiba factory. 8.5. DCDC1-4 and LDO1-3 Power-Up Sequence and Turn-Off Sequence Once the VBAT is asserted or the DCIN is asserted, VSYS is available with LDO3 is ON. In the active mode, DCDCn and LDOn converters power up with output voltage in the sequence as below. Power-Up Sequence 1: DCDC1 -> EXT_EN -> DCDC2 -> DCDC4-> LDO2, DCDC3 -> LDO1 Power-Up Sequence 2: DCDC1 -> DCDC2 -> EXT_EN -> DCDC4-> LDO2, DCDC3 -> LDO1. Turn-Off Sequence 1: LDO1 -> DCDC3, LDO2 -> DCDC4 -> DCDC2 -> EXT_EN -> DCDC1 Turn-Off Sequence 2: LDO1 -> DCDC3, LDO2 -> DCDC4 -> EXT_EN -> DCDC2 -> DCDC1 Power up/Turn off sequence can be controlled by register ( 0x07[D7]). At the power up sequence, when the output voltage of a given rail reaches 80% (Typ.) of the set voltage, the following rail will start after adding setting delay time. At the turn down sequence, when the output voltage of a given rail reaches 20% (Typ.) of the set voltage, the following rail will start after adding setting delay time. All turn off sequences use active discharge mode. Refer to specification of resistance for active discharge. Active discharge is always on at disable of each DCDCs and LDOs. LDO3 is always ON. Only time LDO 3 is OFF is in Power Down state. Turn-Off Sequence is the reverse of power up sequence or same time (no delay). The Turn Off sequence is selected by register ( 0x07[D6]).

2015-6-5 13 © 2015 TOSHIBA Corporation Figure: 4 Power Up Sequence ( 0x07[D7]=0) *Delay 1 to 3 Set by Register ( 0x06) Figure: 5 Turn Off Sequence ( 0x07 [D6] =1) Figure: 6 Turn Off Sequence ( 0x07[D6]=0, 0x07[D7] =0) *Delay 1 to 3 Set by Register ( 0x06) LDO2 (2.8V) LDO1 (1.8V) DCDC1 (1.0V) EXT_EN DCDC2 (1.35V) DCDC3 (3.3V) DCDC4 (1.8V) Power Down OFF Power Down OFF Power Down Power Down Power Down Power Down OFF OFF OFF OFF OFF State moves to STANDBY/OFF State moves to ACTIVE Start up ON 80% ON Start up ONDLY2 (2ms) 80% Start up ONDLY3 (1ms) LDO2 (2.8V) LDO1 (1.8V) DCDC1 (1.0V) EXT_EN DCDC2 (1.35V) DCDC3 (3.3V) DCDC4 (1.8V) 80% Start up ON 80% Start up ONFixed (2ms) Fixed (2ms) Start up ONFixed (0.5ms) 80% DLY1 (1ms)EXT_EN DLY1 (1ms) LDO2 (2.8V) LDO1 (1.8V) DCDC1 (1.0V) EXT_EN DCDC2 (1.35V) DCDC3 (3.3V) DCDC4 (1.8V) Fixed (2ms) Power Down OFF Fixed (0.5ms) 20% Power Down OFF Power Down DLY3 (1ms) Power Down Power Down OFF OFF OFF OFF OFF 20% 20% 20% DLY2 (1ms) Fixed (0.5ms) State moves to STANDBY/OFF Power Down

2015-6-5 14 © 2015 TOSHIBA Corporation Figure: 7 Example 1: (VBAT assert -> PB -> PB -> VUVLO-> DCIN assert) 0x07[D7]=0 Figure: 8 Example 2 0x07[D7]=0 (VBAT assert -> DCIN assert -> DCIN removed -> SYS_LOW -> VUVLO-> PB -> VPOR) 0x07[D6]=1 0x07[D6]=0 VPOR RTC DELAY HW STANDBY Vo=LDO3 80% DLY3 (1ms) DLY2 (2ms) 100ms (Deglich) Under 8s 80% 80% 2ms (fix) 2ms (fix) 80% 0.5ms (fix) 95% PGD LY (200ms) LDO3 50ms I2C access timeout 50ms I2C access timeout 50ms SOC Shutdown ti me Under 8s 50ms I2C access timeout 20% 20% 0.5ms (fix) 0.5ms (fix) 20%2ms (fix) DLY3 (1ms) 20% DLY1 (1ms) DLY2 (2ms) ACTIVE SW STANDBY O ver 1s Battery Power down VPOR VUVLO USB assert USB Detect OFF 5ms (fix) I2C access timeout 80% Battery DCIN VSYS PB INT STANDBY bit (from SOC) LDO3 (RTC 1.8V) LDO1 (1.8V) LDO2 (2.8V) DCDC1 (1.0V) EXT_EN DCDC2 (1.35V) DCDC3 (3.3V) DCDC4 (1.8V) PGOOD Status ACTIVE DLY1 (1ms) DLY1 (1ms) Vo=LDO3 DLY3 (1ms) DLY2 (2ms) 80% 80% 2ms (fix) 2ms (fix) 80% 0.5ms (fix) 95% SOC Read & Clear VPOR RTC DELAY HW STANDBY LDO3 80% DLY3 (1ms) DLY2 (2ms) 80% 80% 2ms (fix) 2ms (fix) 80% 0.5ms (fix) 95% PGD LY (200ms) LDO3 I2C access timeout 5ms ACTIVE HW STANDBY OFF USB Detect USB assert USB remove Battery Power down VSYS_LOW VPOR VUVLO 50ms I2C access timeout Push Bottom O ver 1s VBAT < VPOR 50ms I2C access timeout Power Down Battery DCIN VSYS PB INT STANDBY bit (from SOC) LDO3 (RTC 1.8V) LDO1 (1.8V) LDO2 (2.8V) DCDC1 (1.0V) EXT_EN DCDC2 (1.35V) DCDC3 (3.3V) DCDC4 (1.8V) PGOOD Status DLY1 (1ms)

2015-6-5 15 © 2015 TOSHIBA Corporation 9. LED Driver for LCD backlight Function Figure: 9 LED Driver Block diagram State of this function is transferred to the operation mode by LEDD setting register ( 0x08). DCDC controller and constant current regulators are controlled by inputting signal from LEDD_EN terminal or I 2C command ( 0x00[D7]). TC7734FTG contains a boost converter and two current sinks capable of driving up to 2 LED strings at 80 mA. The numbers of LEDs per string can be up to 20 V. But need to care the SW current limit (1 A). Power supply for step-up Controller is from VDD4. So, VDD4 must connect decoupling capacitance. Unused OUT terminals are detected when the State moves to Active state. When unused LED terminals is detected, it is eliminated from object of control and its constant current operation is turned off. Then, voltage boosting starts and the operation moves to the soft start. Soft start function is limited the SW terminal peak current. It is increased step by step. The condition in which a soft start completes is constant current regulators (LED1, LED2) are generated by operation and the voltage of minimum LEDn terminal reaches about 0.4 V. Brightness dimming is supported by I 2C control ( 0x08 [5:0]). The PWM frequency is set to 195 Hz. The brightness dimming can be adjusted by 32 steps. Error Detect Block Current Regulator1 LED1 LED2 Short Detector Open Detector Current Regulator2 Unused Chanel Detector Over Voltage Detector Step-up Controller OSC (1MHz) Error Amplifier Current Regulator Logic LED Current Controller ISET 0.4V (MIN) FBLED Chanel Status LEDD_EN Dimming Control PGND5 SW SDA SCL Soft Start ON/OFF Control I2C VDD4 C22 4.7µF C14 4.7µF C23 4.7µF R14 300kΩ R15 13kΩ R13 91kΩ 22µH SD1

2015-6-5 16 © 2015 TOSHIBA Corporation 9.1. LED Driver Operating Mode Chart Figure: 10 controlled by I2C command Figure: 11 LEDD_EN control VSYS Unused channel detection SW OSC (1MHz) VLED 1 ms (Typ.) Soft start ILED1 ILED2 LEDD_EN Unused channel detection 1 ms (Typ.) Soft start On timing: Set by I2C On timing: Set by I2C VSYS Unused channel detection SW OSC (1MHz) VLED 1 ms (Typ.) Soft start ILED1 ILED2 Both terminal voltages reach to 0.4V

2015-6-5 17 © 2015 TOSHIBA Corporation Figure: 12 LEDD_EN control and dimming control 9.2. Unused Channel Detection When change the state of LED driver to active by LEDD_EN or I2C, unused channel detection is operated before soft start. This function detects that the LEDn terminals (LED1 or LED2) is connected to PGND at the same voltage. Connect the LEDn terminals of unused channel to PGND. The constant current block of unused channel is turned off and removed from the object of LED open detection and LED short detection. 9.3. Dimming Control Dimming function can operate by internal register setting. The PWM frequency is set to 195 Hz. The PWM duty cycle can be adjusted by 32 steps through the LEDDCTRL register ( 0x08[5:0]). 9.4. Constant Current Setting Constant current (ILED) is set by RISET resistance connected between ISET terminal and GND. ILED is provided by the equation 1 below. ILED (mA) = 1.24(V) × 1487 ÷ (RISET (kΩ) + 1.19 (kA)) Dimming setting 0x08[5:0] VSYS Unused channel detection SW OSC (1MHz) VLED 1 ms (Typ.) Soft start ILED1 ILED2 LEDD_EN

2015-6-5 18 © 2015 TOSHIBA Corporation 9.5. LED Driver Error Detection Function Refer to “Protection Functions” section in detail Table: 2 Function of Detections Detection Function Conditions for starting detection OVD SW (Switch) operation stops when the voltage of FB_LED rises to the detecting voltage or more. SW operation restarts when the voltage falls below the detecting voltage. Always active LED open Operations of LEDn terminals, which are detecting voltage or less just after OVD detection, are turned off. They are eliminated from object of controlling the minimum LEDn terminal voltage. When all operations of LEDn terminal are turned off because of the abnormal state, all LED driver functions are turned off. Just after OVD detection LED short Detection starts 6µs (typ.) after Dimming start timing, which are detecting voltage or more, are turned off. They are eliminated from object of controlling the minimum LEDn terminal voltage. When all operations of LEDn terminal are turned off because of the abnormal state, all LED driver functions are turned off. From 6 µs (typ.) after Dimming start timing. Table: 3 State of Each Block in Detection Detection Conditions LED Driver Block Method of re-startup Step-up control Constant current OVD VOVD > 1.228 V (Typ.) @ VFB_LED rising Stop Continue The voltage is OVD recovery voltage or less. LED Open LED1 or LED2 VLEDn < 0.2 V (Typ.) Active Only error terminal: Stop Re-started the LED driver LED1 and LED2 Stop Stop Re-started the LED driver LED Short LED1 or LED2 VLEDn > 5 V (Typ.) Active Only error terminal: Stop When short error is released, it is resumed at the next dimming cycle LED1 and LED2 Stop Stop

2015-6-5 19 © 2015 TOSHIBA Corporation 10. Power Path Function Power path function consists of Q1, Q2 and Q3 Figure: 13 Power path block diagram Q1: 1) Detect current from DCIN. If this current reaches over-current condition, IC reduces the supply current to the charger block. If need to reduce further, IC conducted the current limit to VSYS by Q2. 2) Block the backflow current from VBAT to DCIN. Q2: 1) Current limit to VSYS when it requires the over current. 2) Block the voltage to VSYS when DCIN voltage is over 5.8 V. Q3: 1) Voltage supplies from VBAT to VSYS when no DCIN power source. 2) Stop the voltage supply from VBAT to VSYS when discharge mode is OFF or the current is over the limit of VBAT to VSYS. 3) Supplement current from VBAT to VSYS when the load demands higher current than the DCIN can support The power path allows simultaneous and independent charging of the battery and powering of the system. This feature enables the system to run with a defective or absent battery pack and allows instant system turn-on even with a totally discharged battery. Charging current is automatically reduced when system load increases and if the system load exceeds the maximum current of the DCIN supply. A block diagram of the power path is shown in Figure: 13 and an example of the power path management function is shown in Figure: 14 and Figure: 15. 10.1. Dead Battery (DUVLO > VBAT) DCIN input is valid and the chip powers up if DCIN rises above 4.3 V. Note that the rise time of DCIN must be less than 50 ms for the detection circuits to operate properly. If the rise time is longer than 50 ms, the IC may fail to power up. 10.2. Good Battery (VBAT > DUVLO) DCIN supply is detected when the input is 125 mV above the VBAT voltage and is considered absent when the voltage difference to the VBAT is less than 40 mV. This feature ensures that DCIN supply is used whenever possible to save battery life. DCIN input is current limited and controlled through the register ( 0x0D[D3:D0]). In case DCIN is not present or blocked by the power path control logic (e.g. in OFF state), VBAT always supplies the system (VSYS pin). 50 kΩ 5 kΩ 100 kΩ 100 kΩ 1000 pF Back Gate Control DCIN MID VSYS VBAT Over Voltage Protect Circuit (Recommended circuit By external parts) Battery Charger Block 2.2 µF 4.7 µF Tr1 ZD1

2015-6-5 20 © 2015 TOSHIBA Corporation 10.3. DCIN Input Discharge DCIN inputs have 25 kΩ internal resistor which are used to discharge the input pins to avoid false detection of an input source. Table: 4 DCIN Current limit setting and how to supply to VSYS Figure: 14 Timing chart in DCP or Other (DCIN current limit = 1500 mA setting) Mode Current Limit Normal ( ISYS < DCIN Current limit) DPPM ( ISYS > DCIN Current limit) 1500 mA(DCP) SYS power is supplied from DCIN DCIN current save to 500 mA 1000 mA(CDP) SYS power is supplied from DCIN DCIN current save to 500 mA 500 mA(SDP) SYS power is supplied from DCIN DCIN current save to 500 mA 0mA Charge current < 50mA 500mA 1500mA Battery Discharge (Q3 = ON) DCIN Current DPPMNormal Normal DCIN voltage VSYS voltage Battery voltage Current profile in DCP Voltage profile in DCP Battery current < 50mA Actual current curve is depended on switching regulator ’s efficiency and input voltage such as DCIN, VBAT. So, this curve is reference.

2015-6-5 21 © 2015 TOSHIBA Corporation Figure: 15 Timing chart in CDP (DCIN current limit = 1000 mA setting) Figure: 16 Timing chart in SDP (DCIN current limit = 500 mA setting) 0mA Charge current < 50mA Battery current < 50mA 1000mA Battery Discharge (Q3 = ON) DCIN Current DPPMNormal Normal 500mA DCIN voltage VSYS voltage Battery voltage Current profile in CDP Voltage profile in CDP 0mA 500mA Battery Discharge (Q3 = ON) DCIN Current DPPMNormal Normal DCIN voltage VSYS voltage Battery voltage Current profile in SDP Voltage profile in SDP Battery current < 50mA Charge current < 50mA Actual current curve is depended on switching regulator ’s efficiency and input voltage such as DCIN, VBAT. So, this curve is reference. Actual current curve is depended on switching regulator ’s efficiency and input voltage such as DCIN, VBAT. So, this curve is reference.

2015-6-5 22 © 2015 TOSHIBA Corporation 11. Charging Functions 11.1. Input Current Limit Input current from DCIN pin can be limited to a set current automatically or I2C. When input current exceeds the set current, the IC limits the current to the set current automatically. When DCIN voltage falls below the threshold set by I 2C, interrupting signal is generated by setting the current limit to USB100 level (Max 100 mA). To resume the current limit to the former level, interrupt must be deactivated. Table: 5 Input Current Limit Command Table: 6 Apply Result of USB Automatic Detection(Default) Result of source detection (DP / DM detection) DCIN Input Current limit setting Fast Charge Current limit (Typ.) SDP 500 mA 500mA CDP 1000 mA Reg 0x0D [D5:D4] DCP/AC 1,500 mA Reg 0x0D [D7:D6] Non-Compliance USB 1,500 mA Reg 0x0D [D7:D6] DCP: Dedicated Charging Port SDP: Standard Downstream Port CDP: Charging Downstream Port 11.2. CHG_STAT Function CHG_STAT terminal drives current in charge state. 11.3. DCIN Over Voltage Protection Function(OVP) It protects the IC from destruction caused by over voltage. Charger function is turned off when the voltage of DCIN pin 11.4. Charging Operation When DCIN pin is connected, following confirmations start for charge power up. When one of the following conditions is not met, the charge is interrupted. (1) DCIN voltage ≥ DUVLO voltage, DCIN voltage ≤ OVP voltage (2) DCIN voltage > Battery voltage + 125 mV (3) Charge enable mode (Set by I2C) (4) Battery temperature is between high limit and low limit. Table: 7 Charge Command Command Register No. Bit No. Contents CHG_EN 0x02 D3 Control by I2C 11.5. Trickle Charge If Pre-charge state has no problem, charge starts at trickle charge (50% Pre-charge current) under the condition that battery voltage is 2.05 V or less. Command Register No. Bit No. Contents USBILMT[3:0] 0x0D D3-D0 DCIN input current limit ATILMT 0x0B D3 Limit of Automatic Input Current by DCIN voltage INTATIL 0x20 D7 Limit of Automatic Input Current Interrupt

2015-6-5 23 © 2015 TOSHIBA Corporation 11.6. Pre-charge When battery voltage exceeds 2.05 V (typ.), Pre-charge starts with the charge current which is set by the register. Charge continues until the battery voltage reaches the fast charge threshold voltage set by the register. In case Pre-charge has not completed by Pre-charge timer finish, charge stops and informs the timer with interrupting error. Table: 8 Pre-charge Command Command Register No. Bit No. Contents PCI[1:0] 0x0A D7,D6 Pre-charge Current and Trickle charge current CCVTH[2:0] 0x09 D5-D3 Voltage Threshold from Pre-charge to Fast Charge 11.7. Fast Charge (Constant-Current Charge Mode) When fast charge mode enabled, constant-current charge starts under the condition that the battery voltage exceeds the fast charge threshold voltage set by the register. Charge current is limited to the input limit current. Table: 9 Fast Charge Command Command Register No. Bit No. Contents CCI[3:0] 0x0A D5-D2 Current of Fast Charge 11.8. Taper Charge (Constant-Voltage Charge Mode) When the voltage becomes the float voltage set by the register in the fast charge mode, the operation moves to the Taper charge mode. Table: 10 Constant-Voltage Charge Mode Command Command Register No. Bit No. Contents FLTV[1:0] 0x09 D1,D0 Float voltage 11.9. Charge Completion When charge completion is valid, charge is completed if the charge current decreases to the value set by the register. In case charge is not completed within the charge timer finish, charge stops and informs with the interrupt flag. Important, in case Charge Completion function is invalid, interrupt flag is not output with CV charge despite of the charge current decreases to the value set by the register. Users should pay attention that an I 2C control is required to stop the charge. Table: 11 Charge Completion Command Command Register No. Bit No. Contents CT 0x0B D0 Charge Termination CEI[1:0] 0x0A D1,D0 Charge completion current 11.10. Re-charge Re-charge starts when the VBAT voltage falls at a voltage set by the register from the float voltage. However, the following two conditions that charge permission state is in DCIN and charge conditions are prepared before charge input state must be provided to re-start. Whether re-charge is automatic or not depends on the register.

2015-6-5 24 © 2015 TOSHIBA Corporation Table: 12 Re-charge Command Command Register No. Bit No. Contents ATRCHGTH 0x0B D7 Threshold for automatic Re-charge ATRCHG 0x0B D6 Automatic Re-charge function setting 11.11. Safety Timer Safety timer has Pre-charge Safety Timer of 30 min (Default) and Charge Safety Timer of 480 min (Default). Timer of 30 min (Default) starts and trickle charge starts after Pre-charge is ready. And it is reset when the operation transferred from Pre-charge mode to fast-charge mode. Timer of 480 min (Default) also starts after Pre-charge is ready and stop when charge completion current does not reach the set value within timer on. Whether trickle charge is included or not at start both timers can be selected. Both timers function is defined as below. When ISYS > DCIN current limit, battery charging will stop, safety timer will be paused, and the power path will draw current from the battery. When ISYS drops back below DCIN current limit, battery charging will resume and the timer will resume from last paused timer value. If the battery voltage drops below ATRCHGTH threshold during ISYS > DCIN current limit , the timer will be cleared and restarted when battery charging is resumed. The above timer operation will occur in both Active and Standby states and transitions between these states. Charge Safety Timer will be cleared and restarted with the following conditions: DCIN insertion Battery voltage drops below ATRCHGTH threshold Charge Safety Timer is disabled and then enabled by I 2C(0x0C, D1) Auto Re-charge is disabled and then enabled by I2C (0x0B, D6) Pre-charge Safety Timer will be cleared and restarted with the following conditions: DCIN insertion Charge restart Pre-charge Safety Timer is disabled and then enabled by I2C (0x0C, D2) Auto Re-charge is disabled and then enabled by I2C (0x0B, D6) Table: 13 Safety Timer Command Command Register No. Bit No. Contents PRCHGTMS 0x0C D5 Pre-charge Safety Timer CGTMS[1:0] 0x0C D4,D3 Charge Safety Timer TCSTON 0x0C D0 Trickle Charge Safety Timer CHGTMCLR 0x0C D6 Clear of Pre-charge and Charge Safety Timer PCGTM_EN 0x0C D2 Pre-charge Safety Timer enable CGTM_EN 0x0C D1 Charge Safety Timer enable

2015-6-5 25 © 2015 TOSHIBA Corporation Table: 14 Charge Error Function Occurrence factor Charger Circuit Action Deactivate(Resume) Input OVLO generation Charge stop Re-start from main standby mode depending on the improvement. Input DUVLO generation Charge stop Re-start from main standby mode depending on the improvement. DCIN<Vbat+125 mV Charge stop Re-start from main standby mode depending on the improvement. Exceed chip temperature Charge stop temporary The operation resumes automatically depending on the improvement. Battery OVLO generation Charge stop CHG_EN is turned on manually after improvement. Unconnected battery Charge stop CHG_EN is turned on manually after improvement. Charge Timer pass Charge stop CHG_EN is turned on manually. Input voltage fall Charge continues by limiting the current of 100 mA (ATILMT = 0) Voltage rises to the former current limit level by resetting interrupt.

2015-6-5 26 © 2015 TOSHIBA Corporation Table: 15 Charge Completion Function Occurrence factor Charger Circuit Action Deactivate(Resume) Ichg < Iterm Charge completion ( 0x0B[D0] = 0) Table: 16 Interrupt Command Command Register No. Contents INT*** 0x10, 0x20 Factor of interrupt 0x24, 0x25, 0x26 Details of interrupting factor 11.12. Chip Temperature Monitor Chip temperature is monitored during charge. When chip temperature exceeds T OVT, chip temperature monitoring bit is set high (ST_OVT). When chip temperature falls below TOVT - TOVT_HYS, it is set low. Charger and Pre-charge Safety timers and Charge Safety timers stop when chip temperature monitoring bit is set high. Charger re-starts automatically when ST_OVT is set low again. Pre-charge Safety timer and Charge Safety timer resume at time before automatic stop. Timers are not reset. Table: 17 Chip Temperature Monitor Command Command Register No. Bit No. Contents ST_ OVT 0x22 D2 Status: Initial value depends on charger block temperature 11.13. Battery Temperature Monitor Battery thermal detection uses thermistor integrated in battery. (Figure: 18 Thermal detector for battery block diagram) Changing charge profile is set by register (HOTTEMP 0x0E [D2:D1], COLDTEMP 0x0E [D3]) Charge profile: Temperature range 0ºC to 60ºC (See Figure: 17 Battery Charger Profile) (HOTTEMP 0x0E[D2:D1]=01, COLDTEMP (0x0E[D3]=0) Under 0º C : Stop the charging function Under 10º C : Fast charge current limit change under 500 mA in DCP and CDP detect. O ver 45ºC : Change the float voltage to 4.15 V Over 50 ºC : Change the float voltage to 4.10 V Over 60 ºC : Stop the charging function When Change the register of HOTTEMP (0x0E[D2:D1]) and COLDTEMP (0x0E[D3]), Stopping charge point is changed. Charge profile: Temperature range 10ºC to 45ºC (HOTTEMP 0x0E[D2:D1]=00, COLDTEMP (0x0E[D3]=1) Under 10º C : Stop the charging function Over 45 ºC : Stop the charging function Discharge profile: Temperature greater than 65 oC If the following two conditions are satisfied: 1) Battery voltage is over 4 V 2) Temperature greater than 65oC The Battery is discharged using the Active discharge circuit until battery voltage is under 3.7 V. Active discharge current is defined by internal pull down resistor (45 Ω) Discharge function is set by register (DISBAT 0x0E [D4])

2015-6-5 27 © 2015 TOSHIBA Corporation Figure: 17 Battery Charger Profile Figure: 18 Thermal detector for battery block diagram 0ºC 10ºC 45ºC 50ºC 60ºC Float Vpltage 4.15V 4.10V 0ºC 10ºC 45ºC 50ºC 60ºC Fast charge Current 500mA DCP_CCI CDP_CCI FLTV TH TH_REF Battery 0ºC 10ºC 45ºC 50ºC 60ºC 65ºC Discharge Enable (ST_USBAC = '0') VS Internal LDO(3.3V) 3.7V/4.0V Detect Ref Discharge Enable (DISBAT= '1') R18 47 kΩ

2015-6-5 28 © 2015 TOSHIBA Corporation Figure: 19 Thermal detector for battery function 1 Figure: 20 Thermal detector for battery function 2 65ºC 25ºC Event Reach to 65ºC Toy’s Temperature USB Adaptor Discharge Operation Charge Operation STATE Battery Voltage 4.0V 3.7V STANDBY Disconnect Disable No charge Enable Disable Leaving near the window Reach to 3.7V Case1 65ºC 25ºC Event Reac h to 65ºC Toy’s Temperature USB Adaptor Discharge Operation Char ge Operation STA TE Battery Voltage 4.0V 3.7V STANDBY Disconnect Disable No charge Enabl e Leaving near the window Pus h PB for stopping Connec t U SB(CDP ) to play Connect Move into the room ACTIVE 4.2V STANDBY Reac h to 3.7V Disable Char ge Battery voltage is down by active discharge. (Q3 is OFF and VSYS is supplied by DCIN) May need 20h in case of 4000mAh batteryConnect DCIN but no charge cause by operating active discharge. Case2

2015-6-5 29 © 2015 TOSHIBA Corporation 11.14. Power Source Detection Automatic power source detection can be set by the register. Source detection starts as soon as DCIN is connected. Result of detection has four types as follows; non-connection, SDP (Standard Downstream Port), CDP (Charging Downstream Port), and DCP (Dedicated Charging Port). Input current limit can be set depending on the detection state. Table: 18 Power Source Detection Command Command Register No. Bit No Contents ST_STYP<1:0> 0x21 D2,D1 Source detection result Figure: 21 Battery Charge Profile Trickle Charge Pre Charge Fast Charge (CC mode) Taper Charge (CV mode) Safety Timer within 30 min Safety Timer within 480 min CCI : 400 – 1500mA PCI : 75 – 400mA CEI : 50 – 200mA½ PCI FLTV CCVTH 2.1V 4.10V - 4.25V 2.6V - 3.3V

2015-6-5 30 © 2015 TOSHIBA Corporation 11.15. Charge Mode Transition Diagram Figure: 22 Flow Chart of Charger Function REGINI Register Initialization timeout STANDBY TRICKLE Trickle PRECHG Pre-charge CCCHG CC charge CVCHG CV charge CHGEND Full charge Charge END SDP,CDP, DCP,OTHER USBDET USB Detect CHGERR Charger error Charge Error Charge Error Charge Error Charge Error SFTRST 0x02[D7] To CCCHG Recharge To PRECHG Recharge Disable Charge Disable Charge Charge Standby

2015-6-5 31 © 2015 TOSHIBA Corporation 11.16. USB detect diagram with TC7USB40MU Figure: 23 How to connect USB line using TC7USB40MU Figure: 24 Timing chart using TC7USB40MU Deglitch time (50 ms) SCTL DCIN(VBUS) 2D+ 2D− 1D+ 1D− DCIN inserted No connect to D− No connect to D+ Detect USB type Connect to D− Connect to D+ SDP (100 ms) CDP (210 ms) DCP (210 ms) Other (470 ms) Connect to D- Connect to D+ No connect to D- No connect to D+ USB Controller (SOC) TC7734FTG TC7USB40MU S Vcc OE 2D− 1D− 2D+ 1D+ D+ GND D− USB Connector SCTL DCIN

2015-6-5 32 © 2015 TOSHIBA Corporation Figure: 25 Function timing chart detecting USB and charger current setting Figure: 26 Relation with Function timing chart detecting USB and 0x21 register Power Vin > DUVLO POR / USB Switch OFF 20ms Register Initialization Standby DP / DM Detection Chattering eliminate SDP CDP DCP Other 0.5A Charge Start Negotiate Change charging current 1.0A Charge Start 1.5A Charge Start No error50ms USB switch ON Negotiate Change charging current 100ms 210ms 210ms 470ms Power POR / USB Switch OFF Register Initialization Standby DP / DM Detection Chattering eliminate 0.5A Charge Start Change charging current 1.5A Charge Start USB switch ON 0x21 Register (STAT1) ST_USBAC ST_DTBSY ST_PSDST ST_STYP[1:0] D1 D0 ST_PB 0 0 0 00 x 1 1 0 00 x 1 0 1 00 x 1 0 1 11 x 1 0 1 10 x 1 0 1 01 x Vin > DUVLO 20ms SDP CDP DCP Other Negotiate No error50ms Negotiate 100ms 210ms 210ms 470ms USB switch ON USB switch ON USB switch ON Change charging current 1.0A Charge Start 1.5A Charge Start

2015-6-5 33 © 2015 TOSHIBA Corporation 12. LOGIC Functions 12.1. Interrupt/Abnormal Detection The INT pin is used to signal any event or fault condition to the host processor. Whenever a fault or event occurs in the IC the corresponding interrupt bit is set in the INT register ( 0x20), and the open-drain output is pulled low. The INT pin is released (returns to Hi-Z state) and fault bits are cleared when the interrupting INT register is read by the host. Reads of non-interrupting registers shall not clear the INT pin. If a fault persists after reading of INT register, the corresponding INT bit remains set and the INT pin is pulled low again after a maximum of 32 μs. Interrupt events include pushbutton pressed/released, DCIN voltage status change and others as specified in Interrupt/abnormal register section. The MASK bits in the INT register are used to mask events from generating interrupts that may be used for debugging purpose. The MASK settings affect the INT pin only and have no impact on protection and monitor circuits themselves. Note that persisting event conditions such as LED1 or LED2 enabled shutdown can cause the INT pin to be pulled low for an extended period of time which can keep the host in a loop trying to resolve the interrupt. If this behavior is not desired, set the corresponding mask bit after receiving the interrupt and keep polling the INT register to see when the event condition has disappeared. Then unmask the interrupt bit again. Interrupt Function 1. Automatic Input Current Limit 2. Re-charge 3. Charger Error 4. Charge Completion 5. System Error 6. Push Button 7. USB Detection 8. DCDCn, LDOn, LEDD Error Table: 19 Interrupt Function Table1

1 Automatic input

Limit of Automatic Input Current Interrupt 0 (Default) no change in status

1 Status changes (DCIN voltage falls below the threshold set

by I2C[ 0x0B(D5,D4)]) NOTE: To disable interrupt, set ATILMT( 0x0B[D3]) register to “0”.

2 Re-charge Re-Charge Status Change Interrupt

0 (Default) Charge is completed or no change in charge status

1 Charge status changes by “Vbat < Vfloat – 150/300 mV” after charge completion

NOTE: To disable interrupt, set ATRCHG( 0x0B[D6]) register to “0”.

3 Charge Error Charge Status Change Interrupt

0 (Default) No charger error in status

1 Charger status error change

NOTE: Status information is available in STATUS register 0x22.

4 Charge Completion Charge Completion Status Change Interrupt

0 (Default) No charge in charging status or not charging

1 Charge completion status changes when “Ichg < Iterm”

NOTE: Status information is available in STATUS register 0x23.

5 System Error System Status Change Interrupt

0 (Default) no change error in status

1 System status error change

NOTE: Status information is available in STATUS register 0x24.

6 Push Button Pushbutton Status Change Interrupt

0 (Default) No change in status

1 Pushbutton status change

(PB_IN changed high to low or low to high)

2015-6-5 34 © 2015 TOSHIBA Corporation NOTE: Status information is available in STATUS register 0x21[D0].

7 USB Detection USB Detection Interrupt

0 (Default) no change in status

1 DCIN power status detect

(power to DCIN pin has either been applied or removed) NOTE: Status information is available in STATUS register 0x21[D5, D2,D1].

8 DCDCn , LDOn, and

DCDCn, LDOn and LEDD Status Change Interrupt 0 (Default) no change in status

1 DCDCn or LDOn or LEDD status error change

NOTE: Status information is available in STATUS registers 0x25 and 0x26. Table: 20 Interrupt Function Table2 Figure: 27 Interrupt Function timing chart Timeout (SOC does not read) SOC Read Error Interrupt INTATIL D7 INT: Clear Register: Not clear (0x20[D0,D3,D5,D7]) Status: Not clear And if status error continues after INT cleared , Re-output INT output INT: Clear Register: Not clear (0x20[D0,D3,D5,D7]) Status: Not clear And if status error continues after INT cleared , Re-output INT output INTCHGER D5 INTSYSFAULT D3 INTPWFAULT D0 Status Interrupt INTRCHG D6 INT: Clear Register: Clear (0x20[D1,D2,D4,D6]) Status: Not change (0x21[D1,D2,D5]) INT: Clear Register: Clear (0x20[D1,D2,D4,D6]) Status: Not change (0x21[D1,D2,D5]) INTCHGCMP D4 INTPB D2 INTUSBAC D1 0 10 1 Normal TSDNormal TSD Under 8s DCDC3 =OFF I2C access timeout 50ms for degligh 50ms I2C access timeout PB INT PB STATUS 0x21[D0] 0 1 0 DCDC3 STATE STANDBY ACTIVE Under 8s 50ms for degligh 50ms 1 0 STANDBY SOC Read & Clear SOC Read & Clear Register 0x20[D2] 0 1 1 0 10 0 1 0 I2C access timeout INT Error STATUS 0x24 SOC Read & Clear Register 0x20[D3] 0 1 0 TSD Re-output Error Clear Normal Error Clear Re-output Error Interrupt Status Interrupt 5ms 5ms 5ms 5ms 5ms 5ms 40μs Interrupt clear Interrupt clear 40μs 40μs 40μs 40μs 40μs 40μs 40μs 40μs

2015-6-5 35 © 2015 TOSHIBA Corporation 12.2. Password Protection This function prevents specific registers from accidental write access. Read access is not locked for the protected registers so host processor can read them anytime without unlock. But write access is locked by password, so host processor needs to unlock it by writing correct password data (0xAB) to the Password register. When the correct password data (0xAB) is written to Password register, the one I 2C transaction (Note1) is unlocked right after the I 2C transaction of password writing. The unlocked one transaction allows host processor to write to the protected registers. The host processor can write one or m ore the protected registers at once in the one unlocked transaction. After the one unlocked I 2C transaction, the write access to the protected registers is locked. Writing incorrect password data to password register is discarded. Note1: One I2C transaction is from I2C start condition to stop condition, regardless of the access type (read/write). The following registers are protected by this function.  0x03 DEFLDO12  0x04 DEFDCDC12  0x05 DEFDCDC34  0x06 SEQDLY1  0x07 SEQDLY2  0x0F STATE_CONF  0x14 PGMASK 12.3. Power-good Function Power-good is a signal used to indicate if an output rail is in regulation or at fault. Internally, all Power-good signals of the enabled rails are monitored at all times and if any of the signals goes low, a fault is declared. All Power-good signals are internally deglitched. When a fault occurs, all output rails are powered down and the device enters STANDBY state. The following rules apply to the PGOOD output:  The power up default state for Power-good is low. When all rails are disabled, PGOOD is low.  Only enabled rails are monitored. Disabled rails are ignored.  The user can set Power-good mask bits in the PG register ( 0x14) to define which rails affect the PGOOD pin.  LEDD has no effect on the Power-good signal.  Power-good monitoring of a particular rail starts 6ms after the rail has been enabled.  PGOOD output is delayed by the PGDLY (PG register 0x0F[D1:D0]) after the sequencer is done.  If an enabled rail goes down due to a fault (output shorted, TSD, VUVLO), PGOOD is declared low, and all rails are shut-down.  If the user disables a rail, it has no effect on the PGOOD pin.  If the user disables all rails, PGOOD is pulled low. In normal operation PGOOD is high in active state but low in STANDBY and OFF state.

2015-6-5 36 © 2015 TOSHIBA Corporation 13. Protection Functions 13.1. VDD Under Voltage Lockout (VUVLO) Function VUVLO circuit initializes (Defaults) each register and the state enters OFF state in case voltage of VDD drops by I 2C control ( 0x0F, STATE_CONF register). VUVLO function is deactivated by DCIN asserted or PB pressed and the operation recovers in accordance with each register setting. VUVLO circuit monitors the VDD voltage. Need to connect directly between VSYS and VDD for detecting VSYS voltage. 13.2. Thermal Shutdown (TSD) Function In the case that IC temperature exceeds 150°C (Typ.), after wait 1 second, moves to STANDBY state. 13.3. Over Current Limit (OCL) Function OCL function limits the load current of each DCDC converters. Each current limit is as follows: DCDC1: 3.5 A (Min) DCDC2: 2.0 A (Min) DCDC3: 2.0 A (Min) DCDC4: 2.0 A (Min) LDO1: 300 mA (Min) LDO2: 350 mA (Min) LDO3: 120 mA (Min) 13.4. LED Output Open Detection (OOD) and Over Voltage Detection(OVD) In the case that VLED rises and overvoltage is detected while object of feedback control is the minimum of LEDn (LED1 and/or LED2) terminal, voltage boosting stops and the open state of LEDn terminal is detected. Voltage of LEDn terminal that is open does not rise though VLED rises. So, open state is detected by monitoring the voltage of this LEDn terminal. Normal detecting voltage is 0.2 V (typ.) or less. Output Open Voltage Detection ( FB_LED terminal voltage) is 1.228 V (typ.) When open state is detected, operation of only object LEDn terminal is turned off. They are eliminated from feedback control target and report the error status to register. When voltage of FB_LED terminal falls 70 mV (typ.) lower than the detecting voltage after overvoltage is detected, SW operation is resumed. In the case that operation is resumed without abnormity of open, IC resumes to normal operation. Figure: 28 LED Open Detection function chart PB DCIN LEDD_EN VLE D VOUT2 DIM_LED Detecting unused OUT terminal Soft start VOUT1 0.5V Open at OUT2 Open detection Open Exception of control SW operation SW operation SW operation Error Register Confirmation of operation Soft startDetecting unused OUT terminal Confirmation of operation SW operation Reset Operaton Open detection Operaton

2015-6-5 37 © 2015 TOSHIBA Corporation 13.5. LED Short Detection When LED current is ON by internal oscillator, short detection starts in the IC after 6 µs (Typ.) passes. Voltage of LEDn terminal that detects short is defined 5V (Typ.). Short detection operates while LED current outputs. When short state is detected for 2 µs or longer, operation of target LEDn terminal is turned off and they are eliminated from feedback control target. Then IC report the error status to register. However, short state is released during operation, operation of target LEDn terminal is resumed and they become object of feedback control. Then IC erases the error status. To confirm the release of short state, detected LEDn terminal operates with constant current drive for 6 μs(Typ.) after LED current outputs. Figure: 29 LED Short Detection function chart Internal OSC LED Outputs IOUT2 IOUT1 SW operation SW operation SW operation SW operation Reset Error register Short Stop current flow Reset Release short Stop current flow Short detection Clear the flag of Short detection 6μs(Typ.) 6μs(Typ.) 6μs(Typ.) 6μs(Typ.)

2015-6-5 38 © 2015 TOSHIBA Corporation 14. External Parts Selection This IC evaluates the characteristics with the following external parts. So, please select an appropriate external parts in reference to following lists. Value Parts name Parts name Vender Inductor 2.2 μH L1 CDRH4D28NP-2R2NC SUMIDA CORPORATION 2.2 μH L2 CDRH4D28NP-2R2NC SUMIDA CORPORATION 2.2 μH L3 CDRH4D28NP-2R2NC SUMIDA CORPORATION 2.2 μH L4 CDRH4D28NP-2R2NC SUMIDA CORPORATION 22 μH L5 CDRH40D26NP-220NC SUMIDA CORPORATION 2.2 μH L6 CDRH4D28NP-2R2NC SUMIDA CORPORATION Capacitance 4.7 μF C2 C2012X5R1A475K125AA TDK Corporation 2.2 μF C3 C1608X5R1A225K080AC TDK Corporation 10 μF C7 C2012X5R1E106K125AB TDK Corporation 10 μF C8 C2012X5R1E106K125AB TDK Corporation 10 μF C9 C2012X5R1E106K125AB TDK Corporation 10 μF C11 C2012X5R1E106K125AB TDK Corporation 10 μF C13 C2012X5R1E106K125AB TDK Corporation 10 μF C15 C2012X5R1E106K125AB TDK Corporation 4.7 μF C17 C2012X5R1A475K125AA TDK Corporation 4.7 μF C19 C2012X5R1A475K125AA TDK Corporation 4.7 μF C21 C2012X5R1A475K125AA TDK Corporation 4.7 μF C23 C2012X5R1V475K125AC TDK Corporation 10 μF C24 C2012X5R1E106K125AB TDK Corporation 4.7 μF C26 C2012X5R1A475K125AA TDK Corporation SBD - SD1 CUS15I30A TOSHIBA CORPORATION

2015-6-5 39 © 2015 TOSHIBA Corporation 15. I2C Functions 15.1. I2C IF Table: 21 Chip Address MSB LSB ADD 1 0 0 1 1 1 0 W/R 15.2. I2C write mode (Slave address: 0x9C) Each transmissions needs to keep more than one clock between each of them. And TC7734FTG supports the following 2 formats. Figure: 30 Format of write mode Mode1 Mode2 S: Start condition, A: Acknowledge, P: Stop condition 15.3. I2C read mode (Slave address: 0x9D) Setting Bit [8] of Slave Address switches I2C to read mode. The host should send the stop condition (P) finally after it sent the Acknowledge (high). TC7734FTG supports the following 2 formats. Figure: 31 Format of read mode Mode1 S D7 D6 D5 D4 D3 D2 D1 0 A D7 D6 D5 D4 D3 D2 D1 D0 A RS D7 D6 D5 D4 D3 D2 D1 1 A D7 D6 D5 D4 D3 D2 D1 D0 A D7 D6 D5 D4 D3 D2 D1 D0 A - - - D7 D6 D5 D4 D3 D2 D1 D0 A P Slave Address Register Address n Slave Address Data of Register n Data of Register n+1 Data of Register x S: Start condition, A: Acknowledge, RS: Repeat start condition, P: Stop condition S D7 D6 D5 D4 D3 D2 D1 0 A

0 D6 D5 D4 D3 D2 D1 D0

A D7 D6 D5 D4 D3 D2 D1 D0 P Slave Address Register Address n Data of Register n S D7 D6 D5 D4 D3 D2 D1 0 A

1 D6 D5 D4 D3 D2 D1 D0

A D7 D6 D5 D4 D3 D2 D1 D0 A D7 D6 D5 D4 D3 D2 D1 D0 A D7 D6 D5 D4 D3 D2 D1 D0 A - - - Slave Address Register Address n Data of Register n Data of Register n+1 Data of Register n+2 - - - D7 D6 D5 D4 D3 D2 D1 D0 A D7 D6 D5 D4 D3 D2 D1 D0 A P Data of Register n+3 Data of Register x

2015-6-5 40 © 2015 TOSHIBA Corporation 16. Description of Register Register is set by writing data to I2C. The register addresses from 0x00 to 0x29 are for operations. Do not access any other register addresses. 16.1. Register map Table: 22 I2C Register and Function Address Register Name PASSWORD R/W Function 0x00 PWR_EN - R/W Enable/Disable DCDCn converter and LDOn and LEDD. 0x01 STATE1 - R/W Status register1 0x02 STATE2 - R/W Status register2 0x03 DEFLDO12 Protect R/W Set output level of LDO1 and LDO2 0x04 DEFDCDC12 Protect R/W Set output level of DCDC1 and DCDC2 0x05 DEFDCDC34 Protect R/W Set output level of DCDC3 and DCDC4 0x06 SEQDLY1 Protect R/W Set delay time of sequence1 0x07 SEQDLY2 Protect R/W Set delay timing of sequence2 0x08 LEDDIM - R/W Set LEDD PWM Dimming 0x09 CHGCNF1 - R/W Set Charger configration1 0x0A CHGCNF2 - R/W Set Charger configration2 0x0B CHGCNF3 - R/W Set Charger configration3 0x0C CHGCNF4 - R/W Set Charger configration4 0x0D CHGCNF5 - R/W Set Charger configration5 0x0E CHGCNF6 - R/W Set Charger configration6 0x0F STATE_CONF Protect R/W Set status migration condition 0x10 INTMASK - R/W Set Interrupt mask 0x11 SYSERRMASK R/W Set System error Masking 0x12 PWERRMASK R/W Set DCDCn and LDOn error Masking 0x13 LEDDERRMASK R/W Set LEDD error Masking 0x14 PGMASK Protect R/W Set Power-good masking 0x15 PASSWORD - R/W Password Protect 0x20 INT_STAT - R Interrupt 0x21 STAT1 - R Status confirmation1 0x22 STAT2 - R Status confirmation2 0x23 STAT3 - R Status confirmation3 0x24 STAT4 - R Status confirmation4(SYSTEM error Status) 0x25 STAT5 - R Status confirmation5(Power_OCL error Status) 0x26 STAT6 - R Status confirmation6(LED Driver error Status) 0x27 PGMON - R PGOOD monitor 0x28 PRODUCTID - R PRODUCT ID (for Toshiba) 0x29 VALUATIONID - R VALUATION ID (for customer)

2015-6-5 41 © 2015 TOSHIBA Corporation 16.1.1Power Control Register 0x00 (PWR_EN) Table: 23: 0x00 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME LEDD EN DCDC4EN DCDC3EN DCDC2EN DCDC1EN not used LDO2 EN LDO1 EN R/W R/W R/W R/W R/W R/W R R/W R/W Default 0 1 1 1 1 0 1 1 Default clear Yes Yes Yes Yes Yes Yes Yes Yes Default clear2 Yes Yes Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION LEDD EN LEDD Enable/ Disable Control 0 (Default) Disable

1 Enable

DCDC4 Enable/ Disable Control

0 Disable

1 (Default) Enable DCDC3EN DCDC3 Enable/ Disable Control 1 (Default) Enable DCDC2EN DCDC2 Enable/ Disable Control 1 (Default) Enable DCDC1EN DCDC1 Enable/ Disable Control 1 (Default) Enable not used N/A LDO2 EN DCO2 Enable/ Disable Control 1 (Default) Enable LDO1 EN LDO1 Enable/ Disable Control 1 (Default) Enable

2015-6-5 42 © 2015 TOSHIBA Corporation

16.1.2 Status Register1: 0x01 (STATE1)

Table: 24: 0x01 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used not used not used not used not used OFF SW STANDBY ACTIVE R/W R R R R R R/W R/W R/W Default 0 0 0 0 0 0 0 0 Default clear Yes Yes Yes Yes Yes Yes Yes Yes Default clear2 Yes Yes Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION not used N/A not used N/A not used N/A not used N/A not used N/A OFF OFF bit. A logic “1” enters the OFF state in the following conditions: . 1) VPOR < VSYS < VUVLO 2) Set “1” by I2C OFF bit is automatically reset to 0 when it changes to other states. SW STANDBY STANDBY bit. A logic “1” enters STANDBY state in the following conditions: . 1) Set “1” by I2C STANDBY bit is automatically reset to 0 when it changes to other states. ACTIVE ACTIVE bit. A logic “1” enters ACTIVE state in the following conditions: . 1) DCIN(IC detect CDP/SDP) asserted from STANDBY state 2) PB pushed down from STANDBY state (PB = “L”) 3) Set “1” by I2C 4) PB pushed down from OFF state (PB = “L”) 5) DCIN(CDP/SDP) asserted from OFF state Active bit is automatically reset to 0 when it changes to other states.

2015-6-5 43 © 2015 TOSHIBA Corporation

16.1.3 Status Register2: 0x02 (STATE2)

Table: 25: 0x02 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME SFTRST not used DISCHG CHG CHG_EN SDP_CHG_EN CDP_CHG_EN DCP_CHG_EN R/W R/W R R R R/W R/W R/W R/W Default 0 0 0 0 1 1 0 1 Default clear - - - - Yes Yes Yes Yes Default clear2 - - - - Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION SFTRST Soft Reset Command for charger block 0 (Default) Disable NOTE: Charger register is cleared and default value is reloaded. 0x02[D3:D0],0x09 to 0x0E not used N/A DISCHG Discharge Current Monitor from VBAT to VSYS 0 (Default) No current from VBAT to VSYS

1 Flow current from VBAT to VSYS

Charge Current Monitor from DCIN to VBAT 0 (Default) No current from DCIN to VBAT

1 Flow current from DCIN to VBAT

CHG_EN Charger Enable/Disable Control 1 (Default) Enable SDP_CHG_EN SDP Charger Enable in STANDBY and OFF states when VBAT < VSYS_LOW[2:0] threshold. 1 (Default) Enable CDP_CHG_EN CDP Charger Enable in STANDBY and OFF states when VBAT < VSYS_LOW[2:0] threshold. 0 (Default) Disable DCP_CHG_EN DCP Charger Enable in STANDBY and OFF states. 1 (Default) Enable

2015-6-5 44 © 2015 TOSHIBA Corporation

16.1.4 LDO1 and LDO2 Control Register: 0x03(DEFLDO12)

Table: 26: 0x03 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used VLDO2[2:0] not used VLDO1[2:0] R/W R R/W R/W R/W R R/W R/W R/W Default 0 1 1 0 0 1 1 0 Default clear Yes Yes Yes Yes Yes Yes Yes Yes Default clear2 Yes Yes Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION not used N/A VLDO2[2:0] LDO2 Output Voltage Selection LDO2 [V] 000 1.50 001 1.60 010 1.70 011 1.80 100 2.30 101 2.50 110 (Default) 2.80

111 N/A

VLDO1[2:0] LDO1 Output Voltage Selection LDO1 [V] 0000 1.2 0001 1.3 0010 1.4 0011 1.5 0100 1.6 0101 1.7 0110(Default) 1.8 0111 1.9

2015-6-5 45 © 2015 TOSHIBA Corporation

16.1.5 DCDC1 and DCDC2 Control Register: 0x04 (DEFDCDC12)

Table: 27: 0x04 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used VDCDC2[2:0] VDCDC1[3:0] R/W R R/W R/W R/W R/W R/W R/W R/W Default 1 0 1 0 0 0 1 0 Default clear Yes Yes Yes Yes Yes Yes Yes Yes Default clear2 Yes Yes Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION not used N/A VDCDC2[2:0] DCDC2 Output Voltage Selection DCDC2 [V] 000 1.05 001 1.20 010(Default) 1.35 011 1.50 100 1.65 101 1.80 110 1.95 VDCDC1[3:0] DCDC1 Output Voltage Selection DCDC1 [V] 0000 0.90 0001 0.95 0010(Default) 1.00 0011 1.05 0100 1.10 0101 1.15 0110 1.20 0111 1.25 1000 1.30 1001 1.35 1010 1.40

1011 N/A

1100 N/A

1101 N/A

1110 N/A

1111 N/A

2015-6-5 46 © 2015 TOSHIBA Corporation

16.1.6 DCDC3 and DCDC4 Control Register: 0x05 (DEFDCDC34)

Table: 28: 0x05 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME DC4_PS not used not used not used DC3_PS VDCDC3[2:0] R/W R/W R R R R/W R/W R/W R/W Default 0 0 0 0 1 1 1 0 Default clear Yes - - - Yes Yes Yes Yes Default clear2 Yes - - - Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION DC4_PS Phase Select Bit for DCDC4 0 (Default) Phase 1 select (same phase with DCDC1)

1 Phase 2 select (different phase with DCDC1)

DC3_PS Phase Select Bit for DCDC3

0 Phase 1 select (same phase with DCDC1)

1 (Default) Phase 2 select (different phase with DCDC1) VDCDC3[2:0] DCDC3 output voltage control DCDC3 [V] 000 2.70 001 2.80 010 2.90 011 3.00 100 3.10 101 3.20 110 (Default) 3.30 111 3.40

2015-6-5 47 © 2015 TOSHIBA Corporation

16.1.7 Delay Time Setting Register: 0x06 (SEQDLY1)

Table: 29: 0x06 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used not used DLY 3 DLY 2 DLY 1 R/W R R R/W R/W R/W R/W R/W R/W Default 0 0 0 0 0 1 0 0 Default clear - - Yes Yes Yes Yes Yes Yes Default clear2 - - Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION not used N/A DLY 3 DCDC4 Turn-ON Delay Setting Delay time 00 (Default) 1 ms 01 2 ms 10 4 ms 11 8 ms DLY 2 DCDC2 Turn-ON Delay Setting Delay time 00 1 ms 01(Default) 2 ms 10 4 ms 11 8 ms DLY 1 Ext Enable Turn-ON Delay Setting Delay time 00 (Default) 1 ms 01 2 ms 10 4 ms 11 8 ms

2015-6-5 48 © 2015 TOSHIBA Corporation

16.1.8 Output Delay Setting Register: 0x07 (SEQDLY2)

Table: 30: 0x07 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME SEQTYPE PWROFFSEQ not used not used not used DLY3EN DLY2EN DLY1EN R/W R/W R/W R R R R/W R/W R/W Default 0 0 0 0 0 1 1 0 Default clear Yes Yes - - - Yes Yes Yes Default clear2 Yes Yes - - - Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION SEQTYPE DCDCn and LDOn power up/turn off sequence setting bit (Default) Power up: DCDC1 -> EXT_EN -> DCDC2 -> DCDC4-> LDO2, DCDC3 -> LDO1 Power down: LDO1 -> DCDC3 , LDO2 -> DCDC4 -> DCDC2 -> EXT_EN -> DCDC1

1 Power up: DCDC1 -> DCDC2 -> EXT_EN -> DCDC4-> LDO2, DCDC3 -> LDO1

Power down: LDO1 -> DCDC3 , LDO2 - > DCDC4 -> EXT_EN -> DCDC2 -> DCDC1 PWROFFSEQ Turn off sequence setting bit 0 (Default) Each turn off delay time is set by and 0x06 0x07[4:0]. (Same as power on sequence delay time) 1 (DCDC1 to 4 and LDO1,2 shutdown at same time not used N/A not used N/A not used N/A DLY3EN DCDC4 Delay Time Disable Bit (without 80% monitor)

0 DLY3 delay time is disable

1 (Default) DLY3 delay time is enable DLY2EN DCDC2 Delay Time Disable Bit (without 80% monitor) 0 DLY2 delay time is disable. 1 (Default) DLY2 delay time is enable DLY1EN EXT_EN Delay Time Disable Bit (without 80% monitor) 0 (Default) DLY1 delay time is disable.

1 DLY1 delay time is enable

2015-6-5 49 © 2015 TOSHIBA Corporation

16.1.9 LED Driver Dimming Control Register: 0x08 (LEDDIM)

Table: 31: 0x08 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME LEDD_PS not used LEDDIM[5:0] R/W R/W R R/W R/W R/W R/W R/W R/W Default 1 0 0 0 1 1 0 1 Default clear Yes - Yes Yes Yes Yes Yes Yes Default clear2 Yes - Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION LEDD_PS Phase Select Bit for LED Driver 1 (Default) Phase 2 select (different phase with DCDC1) not used N/A not used N/A LEDDIM[5:0] 6-Bit PWM Dimming Control LED Current [%] LED Current [%] 00 0000 0.0 01 0001 53.1 00 0001 3.1 01 0010 56.3 00 0010 6.3 01 0011 59.4 00 0011 9.4 01 0100 62.5 00 0100 12.5 01 0101 65.6 00 0101 15.6 01 0110 68.8 00 0110 18.8 01 0111 71.9 00 0111 21.9 01 1000 75.0 00 1000 25.0 01 1001 78.1 00 1001 28.1 01 1010 81.3 00 1010 31.3 01 1011 84.4 00 1011 34.4 01 1100 87.5 00 1100 37.5 01 1101 90.6 00 1101(Default) 40.6 01 1110 93.8 00 1110 43.8 01 1111 96.9 00 1111 46.9 1X XXXX 100 01 0000 50.0

2015-6-5 50 © 2015 TOSHIBA Corporation

16.1.10 Charger Configuration Register1: 0x09 (CHGCNF1)

Table: 32: 0x09 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used not used not used CCVTH[2:0] FLTV[1:0] R/W R R R R/W R/W R/W R/W R/W Default 1 0 0 1 0 0 1 0 Default clear - - - Yes Yes Yes Yes Yes Default clear2 - - - Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION not used N/A not used N/A not used N/A CCVTH[2:0] Voltage Threshold from Pre-charge to Fast Charge. 000 2.5 V 100 (Default) 2.9 V 001 2.6 V 101 3.0 V 010 2.7 V 110 3.1 V 011 2.8 V 111 3.2 V FLTV[1:0] Float Voltage 00 4.10 V 01 4.15 V 10 (Default) 4.20 V 11 4.25 V

2015-6-5 51 © 2015 TOSHIBA Corporation

16.1.11 Charger Configuration Register2: 0x0A (CHGCNF2)

Table: 33: 0x0A DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME PCI[1:0] CCI[3:0] CEI[1:0] R/W R/W R/W R/W R/W R/W R/W R/W R/W Default 1 1 0 0 0 0 1 0 Default clear Yes Yes Yes Yes Yes Yes Yes Yes Default clear2 Yes Yes Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION PCI[1:0] Pre-charge Current and Trickle charge current Pre-charge Trickle charge 00 75 mA 37 mA 01 100 mA 50 mA 10 250 mA 125 mA 11(Default) 400 mA 200 mA CCI[3:0] Current of Fast Charge 0000 (Default) No change, use Auto Detect CC 1001 1,200 mA 0001 400 mA 1010 1,300 mA 0010 500 mA 1011 1,400 mA 0011 600 mA 1100 1,500 mA 0100 700 mA 0101 800 mA 0110 900 mA 0111 1,000 mA 1000 1,100 mA CEI[1:0] Charge Completion Current. Charging is judged as completed when charging current decreases to the value set by CEI[1:0] or less. 00 50 mA 01 75 mA 10 (Default) 100 mA 11 200 mA

2015-6-5 52 © 2015 TOSHIBA Corporation

16.1.12 Charger Configuration Register3: 0x0B (CHGCNF3)

Table: 34: 0x0B DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME ATRCHGTH ATRCHG ATLMTTH[1:0] ATILMT OVTHL[1:0] CT R/W R/W R/W R/W R/W R/W R/W R/W R/W Default 0 1 0 1 1 1 0 0 Default clear Yes Yes Yes Yes Yes Yes Yes Yes Default clear2 Yes Yes Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION ATRCHGTH Threshold for Automatic Re-Charge. If battery voltage is down below “Float voltage - ATRCHGTH”, IC restart the charge function. 0 (Default) 150 mV 1 300 mV ATRCHG Auto Re-Charge function setting 1 (Default) Enable ATLMTTH[1:0] Threshold Voltage of Automatic Input Current Limit If DCIN voltage is down, DCIN input current sets the limit as 100 mA. 00 3.75 V 01 (Default) 4.00 V 10 4.25 V 11 4.50 V ATILMT Limit of Automatic Input Current , ON /OFF control of ATLMTTH function 1 (Default) Enable Limit of input current is set the limit as 100mA when DCIN falls to the level set by ATLMTTH<1:0>. When interrupt is cleared, it is set to the previous limit level. OVTHL[1:0] Voltage threshold in over charge If battery voltage is over “Float voltage + OVTHL”, IC outputs the interrupt. 00 200 mV 01 150 mV 10 (Default) 100 mV 11 50 mV CT Charge Termination setting. If set to “1”, IC continues to charge even after reaching the battery charge current to CEI setting current. 0 (Default) Permitting termination of charging cycle. 1 Not permitting termination of charging cycle.

2015-6-5 53 © 2015 TOSHIBA Corporation

16.1.13 Charger Configuration Register4: 0x0C (CHGCNF4)

Table: 35: 0x0C DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used CHGTMCLR PRCHGTMS CGTMS[1:0] PCGTM_EN CGTM_EN TCSTON R/W R R/W R/W R/W R/W R/W R/W R/W Default 0 0 1 1 1 1 1 0 Default clear Yes Yes Yes Yes Yes Yes Yes Yes Default clear2 Yes Yes Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION not used N/A CHGTMCLR Clear of Pre-charge Safety Timer and Charge Safety Timer 0 (Default) Normal operation of timer Both Pre-charge timer and Charge timer are cleared. (Pulse command) In this time, status information of Pre-charge and charge timer is cleared. PRCHGTMS Pre-charge Safety Timer 0 (Default) 30 min 1 60 min CGTMS[1:0] Charge Safety Timer 00 240 min 01 300 min 10 360 min 11 (Default) 480 min PCGTM_EN Pre-charge Safety Timer Enable

0 Pre-charge safety timer: Invalid

1 (Default) Pre-charge safety timer: Valid CGTM_EN Charge Safety Timer Enable

0 Charge safety timer: Invalid

1 (Default) Charge safety timer: Valid TCSTON Trickle Charge Safety Timer 0 (Default) Pre-charge safety timer and charge safety timer do not operate in trickle charging. 1 Pre-charge safety timer and charge safety timer operate in trickle charging.

2015-6-5 54 © 2015 TOSHIBA Corporation

16.1.14 Charger Configuration Register5: 0x0D (CHGCNF5)

Table: 36: 0x0D DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME DCP Auto CC CDP Auto CC USBILMT[3:0] R/W R/W R/W R/W R/W R/W R/W R/W R/W Default 1 1 1 0 0 0 0 0 Default clear - - - - Yes Yes Yes Yes Default clear2 - - - - - - - - Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION DCP Auto CC[1:0] DCP Auto Charge Current 00 750 mA 01 1000 mA 10 1250 mA 11 (Default) 1500 mA CDP Auto CC[1:0] CDP Auto Charge Current 00 500 mA 01 750 mA 10 (Default) 1000 mA 11 1500 mA USBILMT[3:0] Limit of DCIN Input Current Normal DPPM 0000 (Default) DCP or Other: 1500 mA CDP: 1000 mA SDP: 500 mA DCP or Other: 500 mA CDP: 500 mA SDP: 500 mA 0001 100 mA 100 mA 0010 300 mA 100 mA 0011 400 mA 100 mA 0100 500 mA 500 mA 0101 700 mA 500 mA 0110 1,000 mA 500 mA 0111 1,200 mA 500 mA 1000 1,400 mA 500 mA 1001 1,500 mA 500 mA

2015-6-5 55 © 2015 TOSHIBA Corporation

16.1.15 Charger Configuration Register6: 0x0E (CHGCNF6)

Table: 37: 0x0E DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used not used not used DISBAT COLDTEMP HOTTEMP[1:0] RTYPE R/W R R R R/W R/W R/W R/W R/W Default 0 0 0 0 0 0 1 0 Default clear - Yes Yes Yes Yes Yes Yes Yes Default clear2 - Yes Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION not used N/A not used N/A not used N/A DISBAT Battery auto discharge enable/disable 0(Default) Disable Stop charge current in cold temperature 0 (Default) 0 ºC 1 10ºC HOTTEMP[1:0] Stop charge current in hot temperature. 00 45ºC 01(Default) 60ºC 10 50ºC

11 N/A

0 (Default) 10 kΩ, ß = 3435 1 100 kΩ, ß = 4100

2015-6-5 56 © 2015 TOSHIBA Corporation

16.1.16 State Configuration Register: 0x0F (STATE_CONF)

Table: 38: 0x0F DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME VSYS_LOW[2:0] Not used VUVLO[1:0] PGDLY[1:0] R/W R/W R/W R/W R R/W R/W R/W R/W Default 0 1 1 0 1 0 1 0 Default clear Yes Yes Yes Yes Yes Yes Yes Yes Default clear2 Yes Yes Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION VSYS_LOW[2:0] 000 2.90 V 100 3.45 V 001 3.00 V 101 3.55 V 010 3.15 V 110 3.65 V 011 (Default) 3.30 V 111 3.75 V not used N/A VUVLO[1:0] 00 2.60 V 01 2.90 V 10 (Default) 3.10 V 11 3.35 V Notes: VUVLO voltage should set lower voltage than VSYS_LOW voltage. PGDLY[1:0] Power-good Delay 00 20 ms 01 100 ms 10 (Default) 200 ms 11 400 ms

2015-6-5 57 © 2015 TOSHIBA Corporation

16.1.17 Interrupt MASK Setting Register1: 0x10 (INTMASK)

Table: 39: 0x10 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME INTATIL_MK INTRCHG_MK INTCHGER_MK INTCHGCMP_MK INTSYSFA ULT_MK INTPB_MK INTUSBAC_MK INTPWFAULT_MK R/W R/W R/W R/W R/W R/W R/W R/W R/W Default 0 0 0 0 0 0 0 0 Default clear Yes Yes Yes Yes Yes Yes Yes Yes Default clear2 Yes Yes Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION INTATIL_MK Limit of Automatic Input Current interrupt Mask 0 (Default) interrupt is issued when status changes (DCIN voltage falls below the threshold)

1 No interrupt is issued when status changes(DCIN voltage falls below the

threshold) NOTE: If no interrupt is issued when status changes, set ATILMT( 0x0B[D3]) register to “0”. INTRCHG_MK Re-charge Status Change Interrupt Mask 0 (Default) Interrupt is issued when charge status change by “Vbat < Vfloat – 150/300 mV” after charge completion

1 No interrupt is issued when charge status change by “Vbat < Vfloat –

150/300 mV” after charge completion NOTE: If no interrupt is issued when charge status changes, set ATRCHG( 0x0B [D6]) register to “0”. INTCHGER_MK Charge Status Change Interrupt Mask 0 (Default) interrupt is issued when charger detects error in status

1 No interrupt is issued even when charger detects the error in status

NOTE: Status information is available in STATUS register 0x22. INTCHGCMP_MK Charge Completion Status Change Interrupt Mask 0 (Default) interrupt is issued when charger detects the charge completion

1 No interrupt is issued when Charger detects the completion in status

NOTE: Status information is available in STATUS register 0x23. INTSYSFAULT_MK System Status Change Interrupt Mask 0 (Default) interrupt is issued when System status error change 1 no interrupt is issued when System status error change NOTE: Status information is available in STATUS register 0x24. INTPB_MK Pushbutton Status Change Interrupt Mask 0 (Default) interrupt is issued when PB status changes 1 no interrupt is issued even when PB status changes NOTE: Status information is available in STATUS register 0x21[D0]. INTUSBAC_MK USB Detection Interrupt Mask 0 (Default) interrupt is issued when DCIN is detect or removed 1 no interrupt is issued when DCIN input is detect or removed NOTE: Status information is available in STATUS register 0x21[D5, D2,D1]. INTPWFAULT_MK DCDCn and LDOn and LEDD Status Change Interrupt Mask 0 (Default) interrupt is issued when DCDCn and LDOn and LEDD status error change 1 no interrupt is issued when DCDCn and LDOn and LEDD status error change NOTE: Status information is available in STATUS registers 0x25 and 0x26.

2015-6-5 58 © 2015 TOSHIBA Corporation

16.1.18 System error Masking Setting Register: 0x11 (SYSERRMASK)

Table: 40: 0x11 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used not used not used not used not used not used SYS_LOW_MK TSD_MK R/W R R R R R R R/W R/W Default 0 0 0 0 0 0 0 0 Default clear - - - - - - Yes Yes Default clear2 - - - - - - Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION not used N/A not used N/A not used N/A not used N/A not used N/A not used N/A VSYS_LOW _MK VSYS_LOW Masking Bit 0 (Default) interrupt is issued when VSYS_LOW status changes 1 no interrupt is issued even when VSYS_LOW status changes TSD _MK TSD Masking Bit 0 (Default) interrupt is issued when TSD status changes 1 no interrupt is issued even when TSD status changes

2015-6-5 59 © 2015 TOSHIBA Corporation

16.1.19 DCDCn and LDOn error Masking Setting Register: 0x12 (PWERRMASK)

Table: 41: 0x12 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used DC4_OCL_MK DC3_OCL_MK DC2_OCL_MK DC1_OCL_MK not used LDO2_OCL_MK LDO1_OCL_MK R/W R R/W R/W R/W R/W R R/W R/W Default 0 0 0 0 0 0 0 0 Default clear - Yes Yes Yes Yes - Yes Yes Default clear2 - Yes Yes Yes Yes - Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION not used N/A DC4_OCL_MK DC4_OCL Masking Bit 0 (Default) interrupt is issued when DCDC4_OCL error status changes 1 no interrupt is issued even when DCDC4_OCL error status changes DC3_OCL_MK DC3_OCL Masking Bit 0 (Default) interrupt is issued when DCDC3_OCL error status changes 1 no interrupt is issued even when DCDC3_OCL error status changes DC2_OCL_MK DC2_OCL Masking Bit 0 (Default) interrupt is issued when DCDC2_OCL error status changes 1 no interrupt is issued even when DCDC2_OCL error status changes DC1_OCL_MK DC1_OCL Masking Bit 0 (Default) interrupt is issued when DCDC1_OCL error status changes 1 no interrupt is issued even when DCDC1_OCL error status changes not used N/A LDO2_OCL_MK LDO2_OCL Masking Bit 0 (Default) interrupt is issued when LDO2_OCL error status changes 1 no interrupt is issued even when LDO2_OCL error status changes LDO1_OCL_MK LDO1_OCL Masking Bit 0 (Default) interrupt is issued when LDO1_OCL error status changes 1 no interrupt is issued even when LDO1_OCL error status changes

2015-6-5 60 © 2015 TOSHIBA Corporation

16.1.20 LEDD error Masking Setting Register: 0x13 (LEDDERRMASK)

Table: 42: 0x13 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used OSD2_MK OSD1_MK OOD2_MK OOD1_MK UULED2_MK UULED1_MK OVD_MK R/W R R/W R/W R/W R/W R/W R/W R/W Default 0 0 0 0 0 1 1 0 Default clear - Yes Yes Yes Yes Yes Yes Yes Default clear2 - Yes Yes Yes Yes Yes Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION not used N/A OSD2_MK OSD2 Masking Bit 0 (Default) interrupt is issued when LED2 OSD error status changes 1 no interrupt is issued even when LED2 OSD error status changes OSD1_MK OSD1 Masking Bit 0 (Default) interrupt is issued when LED1 OSD error status changes 1 no interrupt is issued even when LED1 OSD error status changes OOD2_MK OOD2 Masking Bit 0 (Default) interrupt is issued when LED2 OOD error status changes 1 no interrupt is issued even when LED2 OOD error status changes OOD1_MK OOD1 Masking Bit 0 (Default) interrupt is issued when LED1 OOD error status changes 1 no interrupt is issued even when LED1 OOD error status changes UULED2_MK Un-used LED2 Masking Bit 0 interrupt is issued when LED2 un-used flag status changes 1(Default) no interrupt is issued even when LED2 un-used flag status changes UULED1_MK Un-used LED1 Masking Bit 0 interrupt is issued when LED1 un-used flag status changes 1 (Default) no interrupt is issued even when LED1 un-used flag status changes OVD_MK OVD Masking Bit 0 (Default) interrupt is issued when OVD error status changes 1 no interrupt is issued even when OVD error status changes

2015-6-5 61 © 2015 TOSHIBA Corporation

16.1.21 Power-good Masking Setting Register: 0x14 (PGMASK)

Table: 43: 0x14 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used DC4PG_MK DC3PG_MK DC2PG_MK DC1PG_MK not used LDO2PG_MK LDO1PG_MK R/W R R/W R/W R/W R/W R R/W R/W Default 0 0 0 0 0 0 0 0 Default clear - Yes Yes Yes Yes - Yes Yes Default clear2 - Yes Yes Yes Yes - Yes Yes Default clear : Register set to default in DELAY1 to 3 and OFF Default clear2 : Register set to default in HW STANDBY and ACTIVE Field name BIT DEFINITION not used N/A DC4PG_MK DCDC4 Power-good Masking Bit 0 (Default) PGOOD pin is pulled low if DCDC4_PG is low (DCDC4 does not power up)

1 DCDC4_PG status does not affect the status of the PGOOD output pin

DC3PG_MK DCDC3 Power-good Masking Bit 0 (Default) PGOOD pin is pulled low if DCDC3_PG is low (DCDC3 does not power up)

1 DCDC3_PG status does not affect the status of the PGOOD output pin

DC2PG_MK DCDC2 Power-good Masking Bit 0 (Default) PGOOD pin is pulled low if DCDC2_PG is low (DCDC2 does not power up)

1 DCDC2_PG status does not affect the status of the PGOOD output pin

DC1PG_MK DCDC1 Power-good Masking Bit 0 (Default) PGOOD pin is pulled low if DCDC1_PG is low (DCDC1 does not power up)

1 DCDC1_PG status does not affect the status of the PGOOD output pin

LDO2PG_MK LDO2 Power-good Masking Bit 0 (Default) PGOOD pin is pulled low if LDO2_PG is low (LDO2 does not power up)

1 LDO2_PG status does not affect the status of the PGOOD output pin

LDO1PG_MK LDO1 Power-good Masking Bit 0 (Default) PGOOD pin is pulled low if LDO1_PG is low (LDO1 does not power up)

1 LDO1_PG status does not affect the status of the PGOOD output pin

2015-6-5 62 © 2015 TOSHIBA Corporation

16.1.22 Password Protect Register: 0x15 (PASSWORD)

Table: 44: 0x15 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME PWD[7:0] R/W R/W R/W R/W R/W R/W R/W R/W R/W Default 0 0 0 0 0 0 0 0 Field name BIT DEFINITION PWD[7:0] PWD: Password to unlock the password protected registers 0xAB: Password protected registers are unlocked in the next write cycle The others: No effect (Password protected registers are locked for write access)

2015-6-5 63 © 2015 TOSHIBA Corporation

16.1.23 Interrupt Register: 0x20 (INT_STAT)

Table: 45: 0x20 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME INTATIL INTRCHG INTCHGER INTCHGCMP INTSYSFAULT INTPB INTUSBAC INTPWFAULT R/W R R R R R R R R Default 0 0 0 0 0 0 0 0 Field name BIT DEFINITION INTATIL Limit of Automatic Input Current Interrupt 0 (Default) no change in status by I2C[ 0x0B (D5,D4)]) NOTE: To disable interrupt, set ATILMT( 0x0B[D3]) register to “0”. INTRCHG Re-Charge Status Change Interrupt 0 (Default) Charge is completed or no change in charge status NOTE: To disable interrupt, set ATRCHG( 0x0B [D6]) register to “0”. INTCHGER Charge Status Change Interrupt 0 (Default) No charger error in status NOTE: Status information is available in STATUS register 0x22. INTCHGCMP Charge Completion Status Change Interrupt 0 (Default) No charge in charging status or not charging NOTE: Status information is available in STATUS register 0x23. INTSYSFAULT System Status Change Interrupt 0 (Default) no change error in status NOTE: Status information is available in STATUS register 0x24. INTPB Pushbutton Status Change Interrupt 0 (Default) No change in status

1 PB status change

(PB_IN changed high to low or low to high) NOTE: Status information is available in STATUS register 0x21[D0]. INTUSBAC USB Detection Interrupt 0 (Default) no change in status

1 USB or AC power status detect

(power to DCIN pin has either been applied or removed) NOTE: Status information is available in STATUS register 0x21[D5, D2,D1]. INTPWFAULT DCDCn and LDOn and LEDD Status Change Interrupt 0 (Default) no change in status NOTE: Status information is available in STATUS registers 0x25 and 0x26. These fields are cleared by SOC read access.

2015-6-5 64 © 2015 TOSHIBA Corporation

16.1.24 State Monitoring Register1: 0x21 (STAT1)

Table: 46: 0x21 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used not used ST_USBAC ST_DTBSY ST_PSDST ST_STYP[1:0] ST_PB R/W R R R R R R R R Default 0 0 0 0 0 0 0 0 Field name BIT DEFINITION not used N/A not used N/A ST_USBAC DCIN detection result.

0 Not detect DCIN

1 Detect DCIN

ST_DTBSY Detection of Power Source

0 Not busy

1 Busy

ST_PSDST Detection of Power Source

0 Detecting or not detect DCIN

1 Finish (after judge)

ST_STYP[1:0] USB detection result

00 No connection / No detection / Other

01 SDP (Standard Downstream Port)

10 CDP (Charging Downstream Port)

11 DCP (Dedicated Charging Port)

ST_PB Detection of Push Button

0 Released Button

1 Pushed button

*Please refer to Figure: 26 Relation with Function timing chart detecting USB and 0x21 register

2015-6-5 65 © 2015 TOSHIBA Corporation

16.1.25 State Monitoring Register2: 0x22 (STAT2)

Table: 47: 0x22 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME ST_DISBAT ST_VBATN ST_BATOV ST_DCOVL ST_DCUVL ST_OVT ST_BATHT ST_BATLT R/W R R R R R R R R Default 0 0 0 0 0 0 0 0 Field name BIT DEFINITION ST_DISBAT

0 No Battery Discharge

1 Battery Discharge

Note: Interrupt shall only occur on transition from no discharge to discharge. ST_VBATN Status: Initial value depends on DCIN input and battery voltage.

0 DCIN – 125 mV >= VBATT

1 DCIN – 125 mV < VBATT

ST_BATOV Status: Initial value depends on battery voltage.

0 Battery OVLO not detect

1 Battery OVLO detect

ST_DCOVL Status: Initial value depends on DCIN voltage.

0 DCIN OVLO not detect

1 DCIN OVLO detect

ST_DCUVL Status: Initial value depends on DCIN voltage.

0 DCIN UVLO not detect

1 DCIN UVLO detect

ST_OVT Status: Initial value depends on charger block temperature. 0 Chip temperature is normal. Charger operates 1 IC detects high Chip temperature (TOVT). Charger stops to limit internal temperature ST_BATHT Status: Initial value depends on battery temperature. Detect temperature is set by 0x0E[D2:D1].

0 High temperature of battery is not detected

1 High temperature of battery is detected. ST_BATLT Status: Initial value depends on battery temperature. Detect temperature is set by 0x0E[D0]. 0 Low temperature of battery is not detected. 1 Low temperature of battery is detected.

2015-6-5 66 © 2015 TOSHIBA Corporation

16.1.26 State Monitoring Register3: 0x23 (STAT3)

Table: 48: 0x23 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME ST_TMER[1:0] ST_CGED1 ST_CGED0 ST_TRCHG ST_CGMD[1:0] not used R/W R R R R R R R R Default 0 0 0 0 0 0 0 0 Field name BIT DEFINITION ST_TMER[1:0] Safety Timer 00 Time out is not generated. 01 Pre-charge timer: pass. 10 Charging timer: pass. 11 Charge start is waited. ST_CGED1 Charge completion

0 Not complete the Charge function

1 At least, one cycle starts and completes. And output interrupt. If DCIN is disconnected, this status is cleared. ST_CGED0 Charge completion: Initial value depends on charge current.

0 Charge current does not reach the CEI current in Taper Charge mode

1 Charge current reaches the CEI current in Taper Charge mode

ST_TRCHG Trickle charge mode Status

0 No Trickle charge mode

1 Trickle charge mode (VBATT < 2.05 V) ST_CGMD[1:0] Charge Mode

00 No charge

01 Pre-charge, Trickle charge

10 Fast Charge (Constant-Current Charge Mode)

11 Taper Charge (Constant-Voltage Charge Mode)

2015-6-5 67 © 2015 TOSHIBA Corporation

16.1.27 State Monitoring Register4: 0x24 (STAT4)

Table: 49: 0x24 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used not used not used not used not used not used ST_VSYS_LOW ST_TSD R/W R R R R R R R R Default 0 0 0 0 0 0 0 0 Field name BIT DEFINITION not used N/A not used N/A not used N/A not used N/A not used N/A not used N/A ST_VSYS_LOW SYS_LOW detection

0 VSYS > VSYS_LOW

1 VSYS =< VSYS_LOW

ST_TSD TSD error status check

0 IC chip temperature < TSD

1 IC chip temperature >= TSD

2015-6-5 68 © 2015 TOSHIBA Corporation

16.1.28 State Monitoring Register5: 0x25 (STAT5)

Table: 50: 0x25 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used ST_OCLDC4 ST_OCLDC3 ST_OCLDC2 ST_OCLDC1 not used ST_OCLLDO2 ST_OCL LDO1 R/W R R R R R R R R Default 0 0 0 0 0 0 0 0 Field name BIT DEFINITION not used N/A ST_OCLDC4 DCDC4 OCL detection

0 DCDC4 OCL not detect

1 DCDC4 OCL detect

ST_OCLDC3 DCDC3 OCL detection

0 DCDC3 OCL not detect

1 DCDC3 OCL detect

ST_OCLDC2 DCDC2 OCL detection

0 DCDC2 OCL not detect

1 DCDC2 OCL detect

ST_OCLDC1 DCDC1 OCL detection

0 DCDC1 OCL not detect

1 DCDC1 OCL detect

ST_OCL LDO2 LDO2 OCL detection

0 LDO2 OCL not detect

1 LDO2 OCL detect

ST_OCL LDO1 LDO1 OCL detection

0 LDO1 OCL not detect

1 LDO1 OCL detect

2015-6-5 69 © 2015 TOSHIBA Corporation

16.1.29 State Monitoring Register6: 0x26 (STAT6)

Table: 51: 0x26 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used ST_OSD2 ST_OSD1 ST_OOD2 ST_OOD1 ST_UULED2 ST_UULED1 ST_OVD R/W R R R R R R R R Default 0 0 0 0 0 0 0 0 Field name BIT DEFINITION not used N/A ST_OSD2 LED2 OSD detection

0 LED2 OSD not detect

1 LED2 OSD detect

ST_OSD1 LED1 OSD detection

0 LED1 OSD not detect

1 LED1 OSD detect

ST_OOD2 LED2 OOD detection

0 LED2 OOD not detect

1 LED2 OOD detect

ST_OOD1 LED1 OOD detection

0 LED1 OOD not detect

1 LED1 OOD detect

ST_UULED2 LED2 Un-used detection

0 LED2 Un-used not detect

1 LED2 Un-used detect

ST_UULED1 LED1 Un-used detection

0 LED1 Un-used not detect

1 LED1 Un-used detect

ST_OVD LEDD OVD detection

0 FBLED < OVD detecting threshold

1 FBLED >= OVD detecting threshold

2015-6-5 70 © 2015 TOSHIBA Corporation

16.1.30 PGOOD Monitoring Register: 0x27 (PGMON)

Table: 52: 0x27 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used DC4 PGM DC3PGM DC2 PGM DC1 PGM not used LDO2 PGM LDO1 PGM R/W R R R R R R R R Default 0 0 0 0 0 0 1 1 Field name BIT DEFINITION not used N/A DC4 PGM DCDC4 Power-good

0 DCDC4 is either disabled or not in regulation

1 DCDC4 is in regulation

0 DCDC3 is either disabled or not in regulation

1 DCDC3 is in regulation

0 DCDC2 is either disabled or not in regulation

1 DCDC2 is in regulation

0 DCDC1 is either disabled or not in regulation

1 DCDC1 is in regulation

0 LDO2 is either disabled or not in regulation

1 LDO2 is in regulation

0 LDO1 is either disabled or not in regulation

1 LDO1 is in regulation

2015-6-5 71 © 2015 TOSHIBA Corporation

16.1.31 PRODUCT ID Register: 0x28 (PRODUCTID)

Table: 53: 0x28 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME PRODUCT_CODE[3:0] not used not used not used not used R/W R R R R R R R R Default 0 0 0 0 - - - - Field name BIT DEFINITION PRODUCT_CODE Product code

0000 TC7734FTG

other N/A(future use) not used N/A not used N/A not used N/A not used N/A

2015-6-5 72 © 2015 TOSHIBA Corporation

16.1.32 Valuation ID Register: 0x29 (VALUATIONID)

Table: 54: 0x29 DATA BIT D7 D6 D5 D4 D3 D2 D1 D0 FIELD NAME not used not used not used not used VAL_CODE[3:0] R/W R R R R R R R R Default 0 0 0 0 0 0 0 0 Field name BIT DEFINITION not used N/A not used N/A not used N/A not used N/A VAL_CODE[3:0] Valuation code

0000 Valuation 1

other N/A(future use)

2015-6-5 73 © 2015 TOSHIBA Corporation 17.Electrical Characteristics 17.1. Absolute Maxumum Ratings (Ta = 25ºC) Characteristic Symbol Rating Unit DC IN terminal voltage VINMAX -0.3 to 6.0 V Supply voltage VDDMAX -0.3 to 6.0 V Maximum of applied voltage for each terminal VI1 (without LED1,LED2,SW, CHG_STAT, VREF) GND – 0.3 to VDD+0.3 or

6.0 V (Lower value is applied)

V LED1,LED2,SW 30 V CHG_STAT GND – 0.3 to DCIN+0.3 V VREF GND – 0.30 to 1.65 Power dissipation PD (Note1,2) 3.5 W Operating temperature Topr -40 to 85 °C Operating junction temperature Tj 150 °C Storage temperature Tstg -55 to 150 °C *The absolute maximum ratings of a semiconductor device are a set of specified parameter values, which must not be exceeded during operation, even for an instant. If any of these rating would be exceeded during operation, the device electrical characteristics may be irreparably altered and the reliability and lifetime of the device can no longer be guaranteed. Moreover, these operations with exceeded ratings may ca use break down, damage and/or degradation to any other equipment. Applications using the device should be designed such that each absolute maximum rating will never be exceeded in any operating conditions. Before using, creating and/or producing design, refer to and comply with the precautions and conditions set forth in this document. Note1: PCB condition is 74 mm × 74 mm × 1.6 mm, 4 layer, FR-4 Note2: When ambient temperature is 25°C or more, reciprocal of saturated heat resistance (1/Rth(j-a)) should be reduced every 1°C rise. 17.2. Operating Voltage Range Characteristics Symbol Min Typ. Max Unit Supply Voltage DCIN 4.3 - 5.5 V VDD 3.4 - 5.5 V 17.3. Power Consumption (Unless otherwise specified VDD = 3.6 V, and Ta = 25ºC) Characteristics Symbol Condition Min Typ. Max Unit Power Consumption IVDD1 OFF State LDO3 No-load DCIN no connect - 80 104 µA IVDD2 Standby State, LDO3 No-load, 0x0E[D4]=0 (default) DCIN no connect - 130 170 µA Standby State, LDO3 No-load, 0x0E[D4]=1 DCIN no connect - 150 200 µA IVDD3 Active State DCDC1,2,3,4: ON No -load LDO1,2,3: ON No -load LEDD: OFF DCIN no connect - 2.1 - mA

2015-6-5 74 © 2015 TOSHIBA Corporation 17.4. System Protection Characteristics (Unless otherwise specified, VDD = 3.6 V, and Ta = 25ºC). Characteristics Symbol Condition Min Typ. Max Unit VUVLO operation voltage VUVLO1 Apply to VDD VUVLO[1:0]=00 - 2.60 - V Apply to VDD VUVLO[1:0]=01 - 2.90 - V Apply to VDD VUVLO[1:0]=10 - 3.10 - V Apply to VDD VUVLO[1:0]=11 - 3.35 - V VUVLO hysteresis voltage VUVLOHYS - 0.05 0.10 0.15 V Thermal shutdown temperature (Design target) TTSD - 120 150 - ºC 17.5. LDO Characteristics (Unless otherwise specified, VDD = 3.6 V, and Ta = 25ºC) Characteristics Symbol Condition Min Typ. Max Unit LDO1 Output voltage accuracy VOUT7 0 to IOUT7 (max) -3 - +3 % Maximum of output current IOUT7 - 300 - - mA Resistance for Active discharge RDLDO1 - 320 400 480 Ω LDO2 Output voltage accuracy VOUT8 0 to IOUT8 (max) -3 - +3 % Maximum of output current IOUT8 - 350 - - mA Resistance for Active discharge RDLDO2 - 320 400 480 Ω LDO3 Output voltage accuracy VOUT9 0 to IOUT9 (max) -3 - +3 % Maximum of outpcurrent IOUT9 - 120 - - mA Resistance for Active discharge RDLDO3 - - 400 - Ω Feedback Regulation Voltage VFBLDO3 - 1.164 1.200 1.236 V Ripple rejection LDO1-3 RR Vinput = 0.2 Vpp IOUT = 100 mA Design target f = 1kHz - 60 - dB f = 10 kHz - 40 - Noise of LDO1 - Vout=1.8 V, 10 Hz to 100 kHz, Cout = 4.7 µF, Iout = 200 mA Design target - 110 - µVrms Noise of LDO2 - Vout = 2.8 V, 10Hz to 100 kHz, Cout = 4.7 µF, Iout = 200 mA Design target - 130 - µVrms Noise of LDO3 - Vout = 1.8 V, 10 Hz to 100 kHz, Cout = 4.7 µF, Iout = 100 mA Design target - 110 - µVrms

2015-6-5 75 © 2015 TOSHIBA Corporation 17.6. DCDCn Converter Characteristics (Unless otherwise specified, VDD=3.6V, and Ta=25ºC) Characteristics Symbol Condition Min Typ. Max Unit DCDCn Output voltage accuracy VOUT1 PWM mode(Design target) -2 - +2 % VOUT2,3,4 PWM mode(Design target) -3 - +3 % Output current DC IOUT1 - - 1.5 1.8 A IOUT2 - - 1.0 1.2 IOUT3 - - 0.8 0.96 IOUT4 - - 0.5 0.6 Output current AC transient IOUT1AC - - - 3.5 A IOUT2AC - - - 1.5 IOUT3AC - - - 1.5 IOUT4AC - - - 1.0 High side current limited(OCL) ILMT1 - 3.5 - - A ILMT2 - 2.0 - - ILMT3 - 2.0 - - ILMT4 - 2.0 - - Discharge Resistance for Active discharge RDDC1 - 160 250 340 Ω RDDC2 - 160 250 340 Ω RDDC3 - 160 250 340 Ω RDDC4 - 160 250 340 Ω DCDC4 Feedback Regulation Voltage VFBDC4 1.164 1.200 1.236 V Switching frequency FPWM - 0.8 1.0 1.2 MHz Soft start time DCDC1 DCDC2 DCDC3 DCDC4 - - - 680 - µs FET on-resistance DCDC1 RDSON1 High-side (VDD1 to LX1) - 110 - mΩ Low-side (LX1 to PGND1) - 70 - mΩ DCDC2 RDSON2 High-side (VDD2 to LX2) - 180 - mΩ Low-side (LX2 to PGND2) - 170 - mΩ DCDC3 RDSON3 High-side (VDD3 to LX3) - 280 - mΩ Low-side (LX3 to PGND3) - 200 - mΩ DCDC4 RDSON4 High-side (VDD4 to LX4) - 280 - mΩ Low-side (LX4 to PGND4) - 210 - mΩ

2015-6-5 76 © 2015 TOSHIBA Corporation 17.7. LED Driver Characteristics (Unless otherwise specified, VDD=3.6V, and Ta=25ºC) Characteristics Symbol Condition Min Typ. Max Unit Switching Frequency fSW - 0.8 1.0 1.2 MHz Maximum Duty Cycle - 90 - - % PWM dimming Frequency I2C Controlled PWM Dimming 157 195 234 Hz LEDn Regulation Voltage 10 mA < ILED < 80 mA - 0.4 - V Trans conductance gM Design target - 0.1 - μS SW On Resistance RSW_ON - - 200 300 mΩ SW Leakage Current ISW_leak VSW = 20 V - - 4 µA SW current limit ISW_lim Peak current 1.0 - - A ISET terminal voltage - - 1.24 - V Channel to Channel Matching ILEDn = 20 mA - - ±3 % ILEDn = 80 mA, Design target ±2 % ILED Current Accuracy ILEDn = 20 mA, Ta = 25°C - - ±1 mA ILEDn = 20 mA, Ta = -40 to 85°C - - ±1.5 mA ILEDn = 80 mA, Ta = -40 to 85°C Design target ±4 mA OSD (LED Short Detection) Threshold - - 5.0 - V OOD (LED Open Detection) Threshold - - 0.2 - V FB_LED terminal input current - - 0 - µA FB_LED terminal Over voltage detecting Threshold VOUT Output rising 1.19 1.228 1.266 V FB_LED terminal Over voltage Hysteresis - - 70 - mV

2015-6-5 77 © 2015 TOSHIBA Corporation 17.8. Charger Characteristics (1) (Unless otherwise specified, VIN = 5.0 V, VFLOAT = 4.2 V, VBAT = 3.7 V, Ta = 0 to 60°C) Characteristics Symbol Condition Min Typ. Max Unit Input voltage DCIN - 4.3 - 5.5 V Input DUVLO voltage VUVLODCIN DCIN rising 3.45 3.60 3.75 V DCIN falling 3.35 3.50 3.65 V Input OVP voltage VOVPDCIN DCIN rising (no glitch filter) 5.65 5.80 5.95 V DCIN falling - 5.65 - V Detect voltage threshold accuracy of DCIN falling in charging VCLACC ATLMTT[]1:0]=01 -4 - +4 % Battery OVLO voltage VBOV N=4,3,2,1 - VFLT+ 0.05*N - V Automatic shutdown threshold VASHDN DCIN - VBAT, DCIN rising (Recover) 87.5 125.0 162.5 mV DCIN - VBAT, DCIN falling(Detection) 20 40 60 mV DCIN current (Active) IDCIN-ACTIVE Charging, not including ICHG, PWM - 2.5 - mA DCIN shutdown current ISHDNDCIN Charging invalid DCIN = 5 V, VBAT = 3.7 V, no load, DCIN>DUVLO, Main Standby mode - 0.6 - μA VS terminal Shutdown current ISHDNVS Charging invalid DCIN = open, VBAT = 3.7 V - 0 2 μA DCIN Reverse current IDCINLK DCIN current when charging is forbidden. DCIN = 0 V, VBAT = 4.2 V - - 2 μA Over-temperature status threshold, Charge block TOVT - 110 130 - °C Over-temperature status threshold hysteresis, Charge block TOVT_HYS - - 10 - °C Test condition is only 25 °C 17.9. Charger Characteristics (2) SW-mode Controller (Unless otherwise specified, VIN = 5.0 V, VFLOAT = 4.2 V, VBAT = 3.7 V, Ta = 0 to 60°C) Characteristics Symbol Condition Min Typ. Max Unit FET on-resistance RDSONCHG High-side (DCIN to LX6), - 233 367 mΩ Low-side (LX6 to PGND6), - 125 200 mΩ Duty cycle D.C. Maximum, High side ON Duty - 100 - % Minimum, High side ON Duty - 0 - % Test condition is only 25 °C

2015-6-5 78 © 2015 TOSHIBA Corporation 17.10. Charger Characteristics (3) Battery Charger (Unless otherwise specified, VIN = 5.0 V, VFLOAT = 4.2 V, VBAT = 3.7 V, Ta = 0 to 60°C) Characteristics Symbol Condition Min Typ. Max Unit Trickle charge to Pre-charge voltage threshold VTRICKLECHG - 1.90 2.05 2.20 V Trickle charge current accuracy ITRICKLECHG VBATT = 1.7 V. Percentage of Pre-charge Current PCI[1:0] - 50 - % Pre-charge to fast charge voltage threshold accuracy VPRECHG CCVTH[2:0] =100 Constant current sense voltage VSENSE IPRECHG = 100 mA - 6.8 - mV IFCHG = 1000 mA - 68 - mV Pre-charge current (Programmable 75mA to 400mA) IPRECHG RSENSE = 68 mΩ, IPRECHG = 400 mA, -80 - 80 mA Fast charge current (Programmable 400mA to 1500mA) IFCHG RSENSE = 68 mΩ, IFCHG = 500 mA, -50 - 50 mA Charge termination current (Programmable 50mA to 200mA) ITERM1 RSENSE = 68 mΩ, IFCHG = 100 mA -30 - 30 mA Float voltage accuracy (Programmable 4.10V to 4.25V,50mV/step) VFLT VFLT = 4.2 V, ICHG = 150 mA -1 - 1 % Automatic Re-charge threshold voltage VRECH 0x0B (ATRCHGTH) setting - 150 - mV - 300 - mV Test condition is only 25 °C

2015-6-5 79 © 2015 TOSHIBA Corporation 17.11. Charger Characteristics (4) Thermal Monitor (Factory Programmable Option) (Unless otherwise specified, VIN = 5.0 V, VFLOAT = 4.2 V, VBAT = 3.7 V, Ta = 0 to 60°C) Characteristics Symbol Condition Min Typ. Max Unit High temperature trip point(65°C) VHOT1 Rth = 10k NTC(10 kΩ@25°C B:3435), Rs = 4.7k, TH falling 34.10 35.23 36.35 %VTH_REF Rth = 100k NTC(100 kΩ@25°C B:4100), Rs = 47k, TH falling 28.28 29.46 30.64 High temperature trip point(60°C) VHOT2 Rth = 10k NTC(10 kΩ@25°C B:3435), Rs = 4.7k, TH falling 37.54 38.78 40.02 Rth = 100k NTC(100 kΩ@25°C B:4100), Rs = 47k, TH falling 32.04 33.38 34.72 High temperature trip point(50°C) VHOT3 Rth = 10k NTC(10 kΩ@25°C B:3435), Rs = 4.7k, TH falling 45.09 46.58 48.07 Rth = 100k NTC(100 kΩ@25°C B:4100), Rs = 47k, TH falling 40.62 42.31 44.01 High temperature trip point(45°C) VHOT4 Rth = 10k NTC(10 kΩ@25°C B:3435), Rs = 4.7k, TH falling 49.13 50.75 52.38 Rth = 100k NTC(100 kΩ@25°C B:4100), Rs = 47k,TH falling 45.36 47.25 49.14 Low temperature trip point(10°C) VCOLD1 Rth = 10k NTC(10 kΩ@25°C B:3435), Rs = 4.7k, TH rising 77.84 79.67 81.51 Rth = 100k NTC(100 kΩ@25°C B:4100), Rs = 47k, TH rising 79.48 81.52 83.56 Low temperature trip point(0°C) VCOLD2 Rth = 10k NTC(10 kΩ@25°C B:3435), Rs = 4.7k, TH rising 84.31 85.94 87.58 Rth = 100k NTC(100 kΩ@25°C B:4100), Rs = 47k, TH rising 86.56 88.24 89.91 NTC thermistor temperature hysteresis INTCHYS Rth = 100k NTC - 2 - ºC Rth = 10k NTC - 2 - ºC Discharge resister in High temperature trip - - - 45 - Ω Test condition is only 25 °C 17.12. Power Path (Unless otherwise specified, VIN = 5.0 V, VFLOAT = 4.2 V, VBAT = 3.7 V, Ta = 0 to 60°C) Characteristics Symbol Condition Min Typ. Max Unit FET on-resistance - DCIN to VSYS - 220 - mΩ DPPM mode set threshold - VBAT > 2.5 V - VBAT -30mV - V DPPM mode unset threshold - VBAT > 2.5 V - VBAT -10mV - V FET on-resistance - VBAT to VSYS - 45 - mΩ Q3 current limit - VBAT to VSYS 2.5 - 3.7 A DCIN current limit - USBILMT[3:0] = 0001 - 90 - mA - SDP connection 400 450 500 - DCP connection 1200 1350 1500 Test condition is only 25 °C

2015-6-5 80 © 2015 TOSHIBA Corporation 17.13. Automatic Power Source Detection (DP/DM) (Unless otherwise specified, VIN = 5.0 V, VFLOAT = 4.2 V, VBAT = 3.7 V, Ta = 0 to 60°C) Characteristics Symbol Condition Min Typ. Max Unit Data detect voltage VDAT_REF - 0.25 0.33 0.40 V D + source voltage VDP_SRC - 0.50 0.60 0.70 V D-source voltage VDM_SRC - 0.50 0.60 0.70 V D+ pull-up voltage VDP_UP - 3.0 3.3 3.6 V Logic threshold VLGC - 0.8 1.2 2.0 V D+ sink current IDP_SINK - 25 100 175 μA D-sink current IDM_SINK - 25 100 175 μA Current source for data connect detection IDP_SRC - 7 10 13 μA Data line leakage resistance RDAT_LKG - 300 - - kΩ D-pull-down resistance RDM_DOWN - 14.25 20.0 24.80 kΩ Test condition is only 25 °C 17.14. Power Source Detection (Unless otherwise specified, VIN = 5.0 V, VFLOAT = 4.2 V, VBAT = 3.7 V, Ta = 0 to 60°C) Characteristics Symbol Condition Min Typ. Max Unit Data connect detection debounce t DCD_DBNC - 10 - - ms Data connect time out tDCD_TIMEOUT - 300 - - ms DP source on time tVDPSRC_ON - 40 - - ms DM source on time tVDMSRC_ON - 40 - - ms Test condition is only 25 °C 17.15. Oscillator (Unless otherwise specified, VIN = 5.0 V, VFLOAT = 4.2 V, VBAT = 3.7 V, Ta = 0 to 60°C) Characteristics Symbol Condition Min Typ. Max Unit Oscillator frequency fOSC - 0.8 1.0 1.2 MHz Timer frequency fTM - 80 100 120 kHz Pre-charge time out tPCTOFC Safety timer(Default) 24 30 36 min Complete charge timeout tCTOFC Safety timer(Default) 384 480 576 min Unconnected battery timer tBATMIS - 65 86 105 ms Test condition is only 25 °C

2015-6-5 81 © 2015 TOSHIBA Corporation 17.16. Logic Inputs/Outputs (Unless otherwise specified VDD = 3.6 V, and Ta = 25°C) Characteristics Symbol Condition Min Typ. Max Unit Input low level VIL SDA,SCL,LEDD_EN terminal - - 600 mV Input high level VIH SDA,SCL,LEDD_EN terminal 1.4 - - V output low level VOL INT,SDA,PGOOD terminal ISINK = 3 mA - - 300 mV leakage current ILK INT,SDA,PGOOD terminal VBIAS = 3 V - - 1 μA VREF Output Voltage VREF - - 1.5 - V PB “Hard Reset Detect” time tHRST Not tested in production - 8 - s PB deglitch time tPBDG Not tested in production - 50 - ms PB internal pull-up resistor RPBPULLUP - - 100 - kΩ PGOOD comparator threshold V PGD Output voltage falling, % of set voltage LDO1 to 3, DCDC1 to 4 - 90 - % VPGR Output voltage rising, % of set voltage LDO1 to 3, DCDC1 to 4 - 95 - % PGOOD deglitch time tPGDG Output voltage falling DCDC1 to 4 2 - 4 ms Output voltage falling LDO1 to 3 1 - 2 ms PGOOD delay time tPGDLY PGDLY[1:0]=00 - 20 - ms PGDLY[1:0]=01 - 100 - ms PGDLY[1:0]=10 - 200 - ms PGDLY[1:0]=11 - 400 - ms 17.17. AC Characteristics for I2C (Unless otherwise specified VDD = 3.6 V, and Ta = 25°C) Characteristics Symbol Condition Min Typ. Max Unit SCL Clock Frequency fSCL CL = 400 pF - - 400 kHz Set-up time START condition Thld CL = 400 pF 0.6 - - µs Hold time START condition tSET1 CL = 400 pF 0.6 - - µs Set-up time STOP condition tSET2 CL = 400 pF 0.6 - - µs Data Set-up time tSET3 CL = 400 pF 100 - - ns Data Hold time tBUF CL = 400 pF 1.3 - - µs LOW period of the SCL clock tLOW CL = 400 pF 1.3 - - µs High period of the SCL clock tHigh CL = 400 pF 0.6 - - µs Rise time of both SDA and SCL signals tR CL = 400 pF - - 300 ns Fall time of both SDA and SCL signals tF CL = 400 pF - - 300 ns Bus free time between a STOP and START condition tHD DAT CL = 400 pF 0 - - µs

2015-6-5 82 © 2015 TOSHIBA Corporation Figure: 32 Definition of timing chart on the I2C SDA SCL thld tBUF P tSET 2 S RS tSET 1 thld tLOW tHigh tSET 3 tR tF tF tR tHD DAT S: Start, RS : Repeat start, P : Stop

2015-6-5 83 © 2015 TOSHIBA Corporation 18. Package dimensions P-VQFN64-0909-0.50-001 Weight: 0.192 g (Typ.) Unit: mm

2015-6-5 84 © 2015 TOSHIBA Corporation RESTRICTIONS ON PRODUCT USE

  • Toshiba Corporation, and its subsidiaries and affiliates (collectively "TOSHIBA"), reserve the right to make changes to the information in this document, and related hardware, software and systems (collectively "Product") without notice.
  • This document and any information herein may not be reproduced without prior written permission from TOSHIBA. Even with TOSHIBA's written permission, reproduction is permissible only if reproduction is without alteration/omission.
  • Though TOSHIBA works continually to improve Product's quality and reliability, Product can malfunction or fail. Customers are responsible for complying with safety standards and for providing adequate designs and safeguards for their hardware, software and systems which minimize risk and avoid situations in which a malfunction or failure of Product could cause loss of human life, bodily injury or damage to property, including data loss or corruption. Before customers use the Product, create designs including the Product, or incorporate the Product into their own applications, customers must also refer to and comply with (a) the latest versions of all relevant TOSHIBA information, including without limitation, this document, the specifications, the data sheets and application notes for Product and the precautions and conditions set forth in the "TOSHIBA Semiconductor Reliability Handbook" and (b) the instructions for the application with which the Product will be used with or for. Customers are solely responsible for all aspects of their own product design or applications, including but not limited to (a) determining the appropriateness of the use of this Product in such design or applications; (b) evaluating and determining the applicability of any information contained in this document, or in charts, diagrams, programs, algorithms, sample application circuits, or any other referenced documents; and (c) validating all operating parameters for such designs and applications. TOSHIBA ASSUMES NO LIABILITY FOR CUSTOMERS' PRODUCT DESIGN OR APPLICATIONS.
  • PRODUCT IS NEITHER INTENDED NOR WARRANTED FOR USE IN EQUIPMENTS OR SYSTEMS THAT REQUIRE EXTRAORDINARILY HIGH LEVELS OF QUALITY AND/OR RELIABILITY, AND/OR A MALFUNCTION OR FAILURE OF WHICH M AY C AU SE LOSS OF HUMAN LIFE, BODILY INJURY, SERIOUS PROPERTY DAMAGE AND/OR SERIOUS PUBLIC IMPACT ("UNINTENDED USE"). Except for specific applications as expressly stated in this document, Unintended Use includes, without limitation, equipment used in nuclear facilities, equipment used in the aerospace industry, medical equipment, equipment used for automobiles, trains, ships and other transportation, traffic signaling equipment, equipment used to control combustions or explosions, safety devices, elevators and escalators, devices related to electric power, and equipment used in finance-related fields. IF YOU USE PRODUCT FOR UNINTENDED USE, TOSHIBA ASSUMES NO LIABILITY FOR PRODUCT. For details, please contact your TOSHIBA sales representative.
  • Do not disassemble, analyze, reverse-engineer, alter, modify, translate or copy Product, whether in whole or in part.
  • Product shall not be used for or incorporated into any products or systems whose manufacture, use, or sale is prohibited under any applicable laws or regulations.
  • The information contained herein is presented only as guidance for Product use. No responsibility is assumed by TOSHIBA for any infringement of patents or any other intellectual property rights of third parties that may result from the use of Product. No license to any intellectual property right is granted by this document, whether express or implied, by estoppel or otherwise.
  • ABSENT A WRITTEN SIGNED AGREEMENT, EXCEPT AS PROVIDED IN THE RELEVANT TERMS AND CONDITIONS OF SALE FOR PRODUCT, AND TO THE MAXIMUM EXTENT ALLOWABLE BY LAW, TOSHIBA (1) ASSUMES NO LIABILITY WHATSOEVER, INCLUDING WITHOUT LIMITATION, INDIRECT, CONSEQUENTIAL, SPECIAL, OR INCIDENTAL DAMAGES OR LOSS, INCLUDING WITHOUT LIMITATION, LOSS OF PROFITS, LOSS OF OPPORTUNITIES, BUSINESS INTERRUPTION AND LOSS OF DATA, AND (2) DISCLAIMS ANY AND ALL EXPRESS OR IMPLIED WARRANTIES AND CONDITIONS RELATED TO SALE, USE OF PRODUCT, OR INFORMATION, INCLUDING WARRANTIES OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, ACCURACY OF INFORMATION, OR NONINFRINGEMENT.
  • Do not use or otherwise make available Product or related software or technology for any military purposes, including without limitation, for the design, development, use, stockpiling or manufacturing of nuclear, chemical, or biological weapons or missile technology products (mass destruction weapons). Product and related software and technology may be controlled under the applicable export laws and regulations including, without limitation, the Japanese Foreign Exchange and Foreign Trade Law and the U.S. Export Administration Regulations. Export and re-export of Product or related software or technology are strictly prohibited except in compliance with all applicable export laws and regulations.
  • Please contact your TOSHIBA sales representative for details as to environmental matters such as the RoHS compatibility of Product. Please use Product in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances, including without limitation, the EU RoHS Directive. TOSHIBA ASSUMES NO LIABILITY FOR DAMAGES OR LOSSES OCCURRING AS A RESULT OF NONCOMPLIANCE WITH APPLICABLE LAWS AND REGULATIONS.