Features
- High power output : POUT MAX (1) = 41 W (typ.) (V CC = 14.4 V, f = 1 kHz, JEITA max, RL = 4 Ω) : POUT MAX (2) = 37 W (typ.) (V CC = 13.7 V, f = 1 kHz, JEITA max, RL = 4 Ω) : POUT MAX (3) = 70 W (typ.) (V CC = 14.4 V, f = 1 kHz, JEITA max, RL = 2 Ω) : POUT (1) = 27 W (typ.) (V CC = 14.4 V, f = 1 kHz, THD = 10%, RL = 4 Ω) : POUT (2) = 23 W (typ.) (V CC = 13.2 V, f = 1 kHz, THD = 10%, RL = 4 Ω) : POUT (3) = 46 W (typ.) (V CC = 14.4 V, f = 1 kHz, THD = 10%, RL = 2 Ω)
- Low distortion ratio: THD = 0.015% (typ.) (V CC = 13.2 V, f = 1 kHz, POUT = 5 W, RL = 4 Ω)
- Low noise: V NO = 90 µVrms (typ.) (V CC = 13.2 V, Rg = 0 Ω, BW = 20 Hz to 20 kHz, RL = 4 Ω)
- Built in stand by & muting function: controlled via I2C Bus (pin 16)
- Built in clipping detection (pin 4)
- Built in I2C Bus for stand-by, mute, voltage gain control, self diagnosis: Output short detection, offset detection, tweeter or speaker open detection (pin 22 and 25)
- Built-in various protection circuits (Note 1, Note 2) Thermal shut down, over-voltage, out to GND, out to V CC, out to out short circuit
- Operating supply voltage: V CC (opr) = 9 to 18 V (RL = 4 Ω) VCC (opr) = 9 to 16 V (RL = 2 Ω) Note 1: Install the product correctly. Otherwise, it may result in break down, damage and/or degradation to the product or equipment. Note 2: These protection functions are intended to avoid some output short circuits or other abnormal conditions temporarily. These protect functions do not warrant to prevent the IC from being damaged. - In case of the product would be operated with exceeded guaranteed operating ranges, these protection features may not operate and some output short circuits may result in the IC being damaged. Weight: 7.7 g (typ.)
Some of the functional blocks, circuits, or constants labels in the block diagram may have been omitted or simplified for clarity . Ripple IN1
9 Out1 (+)
RL = 4 Ω PW-GND1 Out1 (−)
12 IN2
5 Out2 (+)
RL = 4 Ω PW-GND2 Out2 (−)
15 IN3
17 Out3 (+)
RL = 4 Ω PW-GND3 Out3 (−)
14 IN4
21 Out4 (+)
RL = 4 Ω PW-GND4 Out4 (−)
16 Standby
& Mute
13 Pre-GND
4 Clip Detection
- External Component Values Effect Component Name Recommended Value Purpose Lower than Recommended Value Higher than Recommended Value Notes C1 0.22 µF To eliminate DC Cut-off frequency becomes higher Cut-off frequency becomes lower Pop noise is concerned with this capacitor. C2 10 µF To reduce ripple To determine the time of turn on diag Power ON/OFF time and turn ON diag cycle shorter Power ON/OFF time and turn ON diag cycle longer C3 0.1 µF To provide sufficient oscillation margin Reduces noise and provides sufficient oscillation margin C4 1 µF To reduce pop noise Pop noise becomes larger Muting ON/OFF time is shorter Pop noise becomes smaller Muting ON/OFF time is longer C5 3900 µF Ripple filter Power supply ripple filtering Note 3: In case of the recommended value not used. 5. Fast Mute Mode This feature will normally be used to suppress pop noise resulting from VCC transients during engine cranking condition. The fast mute mode can be entered on receipt of a command via I 2C bus. Using the IB2 register and setting to ‘one’ the bit D6, it is possible to generate a fast I2C mute command. If a fast mute command is received, this IC will operate and will discharge the capacitor C4 at pin16. Therefore the Pop sound will be reduced compared to the condition when Fast Mute is not used in the engine cranking condition.
- Explanation for Self Diagnosis Via I 2C (1) Bus map 【Slave Address】 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Details Hex
0 Write Mode
1 Read Mode
1 1 0 1 1 0 0 ⎯ D8H 【WRITE】
- Sub address Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Details Hex
0 Page Mode (auto increment) OFF
1 Page Mode (auto increment) ON
⎯ 0 0 0 0 0 0 1 Control Byte1 01H ⎯ 0 0 0 0 0 1 0 Control Byte2 02H
- Control byte1 (01H) : Initial statement = All “0” Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Function 0 0 0 0 0 0 0 1 Clip Det 1% to 10% change 0 0 0 0 0 0 1 0 R-ch Muting off (play) 0 0 0 0 0 1 0 0 Fch Muting off (play) 0 0 0 0 1 0 0 0 R-ch Gain 26dB to 12dB 0 0 0 1 0 0 0 0 Fch Gain 26dB to 12dB 0 0 1 0 0 0 0 0 Offset Det Enable 0 1 0 0 0 0 0 0 Diag Cycle Enable 1 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ Turn-on Select (normal/repeatedly)
- Control byte2 (02H) : Initial statement = All “0” Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Function 0 0 0 0 0 0 0 1 R-ch Iccq become Lower 0 0 0 0 0 0 1 0 Fch Iccq become Lower 0 0 0 0 0 1 0 0 Current Detection Enable 0 0 0 0 1 0 0 0 Line Drive Diag 0 0 0 1 0 0 0 0 Stand By OFF (play) 0 0 1 0 0 0 0 0 Clip Det Pin change to Offset Det 1 0 0 0 0 0 0 0 Current Detection. Level change from 500 mA (max) to 300 mA (max) Note 4: Self mute circuit is included on chip and is in independent from I 2C bus stage. Self mute operating voltage is VCC = 7.8 V Note 5: Auto Increment is available. If control byte 1 is chosen by sub address, it is not necessary to send byte 2 in cases when both byte 1 and 2 are to be written. Ex) In case of sub address = byte1 chosen: Sub address byte 1 → byte 1 writing → Sub address byte 2 → byte 2 writing: available
【READ】 Byte 1 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 At “Bit = 1” Condition 0 0 0 0 0 0 0 1 Ch1 Short to GND 0 0 0 0 0 0 1 0 Ch1 Short to V CC 0 0 0 0 0 1 0 0 Ch1 Open load or Offset Detected 0 0 0 0 1 0 0 0 Ch1 Short load 0 0 0 1 0 0 0 0 Ch1 Diagnosis condition (bit = 1: permanent, 0: turn-on) 0 0 1 0 0 0 0 0 Ch1 Current Detection (at IB2 D2 = 1 = enable only) (IB2 − D7 = 0: bit = 1: <250 mA, 0: >500 mA) (IB2 − D7 = 1: bit = 1: <100 mA, 0: >300 mA) 0 1 0 0 0 0 0 0 Bit = 1: Diag. Cycle terminated, 0: Not terminated 1 0 0 0 0 0 0 0 TSD Mute ON (thermal warning) Byte 2 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 At “Bit = 1” Condition 0 0 0 0 0 0 0 1 Ch2 Short to GND 0 0 0 0 0 0 1 0 Ch2 Short to V CC 0 0 0 0 0 1 0 0 Ch2 Open load or Offset Detected 0 0 0 0 1 0 0 0 Ch2 Short load 0 0 0 1 0 0 0 0 Ch2 Diagnosis condition (bit = 1: permanent, 0: turn-on) 0 0 1 0 0 0 0 0 Ch2 Current Detection (at IB2 D2 = 1 = enable only) (IB2 − D7 = 0: bit = 1: <250 mA, 0: >500 mA) (IB2 − D7 = 1: bit = 1: <100 mA, 0: >300 mA) 0 1 0 0 0 0 0 0 Current sensor activated (D6 = 1) 1 0 0 0 0 0 0 ⎯ Offset detection activated (D7 = 1) Byte 3 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 At “Bit = 1” Condition 0 0 0 0 0 0 0 1 Ch3 Short to GND 0 0 0 0 0 0 1 0 Ch3 Short to V CC 0 0 0 0 0 1 0 0 Ch3 Open load or Offset Detected 0 0 0 0 1 0 0 0 Ch3 Short load 0 0 0 1 0 0 0 0 Ch3 Diagnosis condition (bit = 1: permanent, 0: turn-on) 0 0 1 0 0 0 0 0 Ch3 Current Detection (at IB2 D2 = 1 = enable only) (IB2 − D7 = 0: bit = 1: <250 mA, 0: >500 mA) (IB2 − D7 = 1: bit = 1: <100 mA, 0: >300 mA) ⎯ 1 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ Diagnotic status (= IB1 − D6 bit = 1: diag enable) 1 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ Stand-by status (= IB2 − D4 bit = 1: play)
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 At “Bit = 1” Condition 0 0 0 0 0 0 0 1 Ch4 Short to GND 0 0 0 0 0 0 1 0 Ch4 2 Short to VCC 0 0 0 0 0 1 0 0 Ch4 Open load or Offset Detected 0 0 0 0 1 0 0 0 Ch4 Short load 0 0 0 1 0 0 0 0 Ch4 Diagnosis condition (bit = 1: permanent, 0: turn-on) 0 0 1 0 0 0 0 0 Ch4 Current Detection (at IB2 D2 = 1 = enable only) (IB2 − D7 = 0: bit = 1: <250 mA, 0: >500 mA) (IB2 − D7 = 1: bit = 1: <100 mA, 0: >300 mA) Note 6: Short circuit protection can be operated channel by channel. EX) If channel 1 output is shorted, channel 1 is protected but other channels are available. Caution: sub address 0x15 (15H) is for our internal testing only. Do not apply for your using.
As initially, the write data is set when the on diagnostic cycle enable (IB1 D6 = 1), the turn on diagnosis can be available for repeated use by sending the read command repeatedly after the initial set up as shown as Figure 5. Therefore, it is useful to check number of cycles from Power ON to the output appearance. This IC has two built-in diagnostic modes dependent on the Turn-on timing. A) Normal mode (one shot) of Turn-on diagnostics (data of IB1, D7 =0) B) Repeatability mode of Turn-on diagnostics (data of IB1, D7 = 1) A) Normal mode (one shot diag.) For example, if you want to get two valid readings, you have to send the command to read three times. True data are second data and third data. The Data just received was detected on the previous diagnostic cycle. This is trigger to enable the diag cycle. Diag cycle with Turn-ON When “Diag enable” goes high, “Latch” is reflected at the “Fault event”. For example Short Load, Open Load etc. I2C command Pin 10 Reading 1 Reading 2 Reading 3 About 100 m Diag enable Fault event Latch DB1 D6 You have to read for an interval of 150 ms or more to get a valid reading. Writing (diag cycle enable = 1) (stand by OFF = 0)
B) Repetition mode The turn ON diagnostic acquisition time is determined by the ripple filter capacitance C2 and the equivalent internal resistance Rr as below expression. Acquisition time = 2 × C2 × Rr = 4400 × C2 (typ.) Rr is fixed in internal circuit and it is not varied by the fluctuation of power supply VCC voltage. C2 value determines the time from power ON (standby off) to the appearance of sound signal from output and the characteristic for ripple rejection ratio, too. So, take care with the decision on C2 value. If the turn ON diagnosis is not used, in other words the diagnostic cycle defeat command is sent, the waveform of ripple terminal voltage will change but the time from turning on to the output signal appearance will not change as illustrated below in Figure 6. Figure 6 Turn on Diagnosis Timing Chart when Turn on diagnosis not used. WRITE DATA Pin10 ripple pin voltage Turn ON diagnosis enable Turn ON diagnosis defeat I2C command Pin 10 Writing (diag cycle enable = 1) (stand by OFF = 0) Reading 2 Reading 3 About 100 ms Diag enable Fault event Latch DB1 D6 (acquisition time with only turn-ON) Reading 4 Reading 5 Reading 6 About 80 ms Maximum interval: You can select the acquisition time. Minimum interval: It is determined by the speed of microcomputer. About 80 ms Reading 1
(3) Description for permanent diagnosis This IC can provide permanent diagnosis under the following conditions, whether they occur before or after turning ON: -Short to GND -Short to VCC -Output to output short circuit -Output offset detection -Current detection for tweeter open This permanent diagnosis is available not only with the diagnostic cycle byte: IB1 D6 set at 1 but also when set at 0. Additionally, the signal can be obtained by entering just a read command. It is not necessary to write the data. With permanent diagnosis fault detection, the first read data after fault removal will still show a Fault. Therefore, it is necessary to obtain 3 or more readings in order to prevent a miss judgment. For example, the speaker sometimes makes a large counter electro motive force which this IC could recognize as a fault event. Additionally, this permanent diagnosis is automatically on after the turning on diagnosis operation finished therefore there is no need to send the extra command. Figure 7 Permanent Diagnosis Timing Chart for Each Short Detection Turn On diagnostic acquisition time (80 ms typ.) Turn On diagnostic DATA permitted time READ DATA WRITE DATA READ DATA result faulty FAULT event Pin10 ripple voltage READ DATA result not faulty FAULT removed READ DATA result faulty Permanent diagnostic DATA permitted time
Regarding operation of the output offset detection, The software always detects the output offset but the result is not latched internally as shown in the Figure below: However, this detection has to be performed in real time: Time voltage offset (Tvos) between read and next read is set at Tvos = 1/the lowest signal frequency ,or more. For instance Tvos > 50 ms if the lowest output signal frequency is 20 Hz, and to obtain 2 or more readings in order not to make a misjudgment Additionaly, the threshold level is designed at +/−2 V. Figure 8 Software Output Offset Detection Timing Chart Turn On diagnostic acquisition time (80 ms typ.) Turn On diagnostic DATA permitted time WRITE DATA READ DATA result faulty FAULT event Pin10 ripple voltage READ DATA result not faulty FAULT removed Permanent diagnostic DATA permitted time READ DATA result not faulty Correct Tvos Correct Tvos
The output from the terminal of pin 4 can be changed from clip detector to offset detector output by sending the write command via I2C. If the L.P.F output voltage has become a half of pull up voltage for a while, firstly the signal output volume goes down (cliping detector function). After that, it can be judged that the abnormal output offset has occurred, if the L.P.F. output voltage does not rise above half of pull up voltage. Offset detector L.P.F. smoothing circuit Volume control circuit System shut down Figure 9 Hardware Output Offset Detection Vth Vth Output waveform Offset detector output pin 4 Waveform L.P.F output Abnormal offset occured Volume down Judgement Waiting time for Prevention misjudgement Detection delay time
When the current detector for Tweeter open check is used, it is neccesary to take care as below: - Need to input the pulse or signal which is the higher out of audience frequency for example f = 20 kHz - The pulse or signal input timing has to be after mute off (play mode) - At least, the read timing has to be after 1 cycle of input pulse or signal and more, the recommadation cycles are 3 cycle and more if can. - The level of input pulse or signal is more than the detection threshold level 300 mA or 500 mA. For instance, if the tweeter impedance is 20 Ω at f = 20 kHz which is same as input signal frequency, the output minimum voltage is: Vout = 500 mA × 20 Ω = 10 V and more. Finally, if DB1 D7 = 1 then the temperature of IC chip is close to the thermal shutdown point. This warning bit becomes high, about 10 degrees below the temperature at which the overtemperature protection operates. Note 7: Timing charts may have been simplified for ease of reading. Note 8: Please arrange to read all self-diagnosis functions twice or more and apply judgment in order to avoid false triggering. <Since the first diagnostic result has low confidence, please diagnose 2 times or more.> Figure 10 Tweeter Open Detection Timing Chart WRITE DATA mute off READ DATA invalidity READ DATA validity READ DATA invalidity READ DATA validity WRITE DATA stand by off mute on READ DATA invalidity Current detector is not effective Effective → Play Mute Mute ON Output
(4) Multiple faults The self diagnosis shows as below tables when there are multi fault connection for the audio outputs. At Turning ON: S.GND (out +) S.GND (out −) S.V CC Out to Out. S Open L open or No open Out to Out.S S.Load S.Load + No open Open L Open At Permanent: S.GND (out +) S.GND (out −) S.V CC Out to Out. S Open L S.GND (out+) S.GND S.GND S.GND or S.VCC (Note 10) S.GND S.GND (Note 9) S.GND (out−) S.GND S.GND or S.VCC (Note 10) S.GND S.GND (Note 9) S.VCC S.V CC S.V CC S.VCC (Note 9) Out to Out.S S.Load + S.GND N/A Open L Normal Note 9: If the DC offset detection mode is ON, the information which the DC offset is appeared is added. Note10: The chance which they can read this exact information is only one time although in case of other diagnosis, the more times sending read command, the higher the confidence of the result. For example, a) ch1+ is connected to GND b) ch1− is connected to V CC c) They can read or get the “Short to GND” information when the uP send the Read command. d) Next, however, they can not get the “Short to GND” or “Short to V CC” information when the uP send the Read command again. Note 11: Please arrange to read all self-diagnosis functions twice or more and apply judgment in order to avoid false triggering. (5) Explanation of I2C bus commands Below the “ADDRESS BYTE”, presently the address byte is fixed at 216 dec = D8hex = 101100xbin. - Address Selection is D8hexa: A7 Address bit 1 A6 Address bit 1 A5 Address bit 0 A4 Address bit 1 A3 Address bit 1 A2 Address bit 0 A1 Address bit 0 A0 (R/W) Read/Write bit X X: 0 = Write instruction to device; 1 = Read instruction to device
- If R/W = 0, the Up Sends Two Instruction Bytes, IB1 and IB2: IB1 Instruction Byte: Bit D7 Turn-on diag timing Normal (D7 = 0) Repeat (D7 = 1) D6 Diagnostic cycle enable (D6 = 1) Diagnostic cycle defeat (D6 = 0) D5 Offset Detection enable (D5 = 1) Offset Detection defeat (D5 = 0) D4 Front Channel Gain = 26dB (D4 = 0) Gain = 12dB (D4 = 1) D3 Rear Channel Gain = 26dB (D3 = 0) Gain = 12dB (D3 = 1) D2 Mute front channels (D2 = 0) Unmute front channels (D2 = 1) D1 Mute rear channels (D1 = 0) Unmute rear channels (D1 = 1) D0 CD 1% (D0 = 0) CD 10% (D0 = 1) IB2 Instruction Byte: Bit D7 Current Det 500 mA (max) (D7 = 0) Current Det 300 mA (max) (D7 = 1) D6 Fast mute on (D6 = 1) off (D6 = 0) D5 Pin4 Clip Detection (D5 = 0) Pin4 Offset Detection (D5 = 1) D4 Std-by on-PA not working (D4 = 0) Std-by off-PA working (D4 = 1) D3 Amplifier mode diagnostic (D3 = 0) Line driver mode diagnostic (D3 = 1) D2 Current Det. diag enabled (D2 = 1) Current Det. diag defeat (D2 = 0) D1 Front Channels Work standard mode (D1 = 0) Work Low Iccq mode (D1 = 1) D0 Rear Channels Work standard mode (D1 = 0) Work Low Iccq mode (D1 = 1)
- If R/W = 1, the Power Amplifier Sends Four Diagnostics Bytes, DB1, DB2, DB3 and DB4: DB1 Diagnostic Byte: Bit D7 Thermal warning active (D7 = 1) D6 Diag not actived or not terminated (D6 = 0) Diag terminated (D6 = 1) D5 Channel 1 current detection Output peak current < 250 mA (IB2 − D7 = 0) − open load (D5 = 1) Output peak current < 100 mA (IB2 − D7 = 1) − open load (D5 = 1) Output peak current > 500 mA (IB2 − D7 = 0) − normal load (D5 = 0) Output peak current > 300 mA (IB2 − D7 = 1) − normal load (D5 = 0) D4 Channel 1 Turn-on diagnostic (D4 = 0) Permanent diagnostic (D4 = 1) D3 Channel 1 Normal load (D3 = 0) Short load (D3 = 1) D2 Channel 1 Turn-on diag: No open load (D2 = 0) Open load detected (D2 = 1) Offset diag: No output offset (D2 = 0) Output offset detected (D2 = 1) D1 Channel 1 No short to VCC (D1 = 0) Short to VCC (D1 = 1) D0 Channel 1 No short to GND (D0 = 0) Short to GND (D0 = 1)
DB2 Diagnostic Byte: Bit D7 Offset detection not activated (D7 = 0) Offset detection activated (D7 = 1) D6 Current sensor not activated (D6 = 0) Current sensor activated (D6 = 1) D5 Channel 2 current detection Output peak current < 250 mA (IB2 − D7 = 0) − open load (D5 = 1) Output peak current < 100 mA (IB2 − D7 = 1) − open load (D5 = 1) Output peak current > 500 mA (IB2 − D7 = 0) − normal load (D5 = 0) Output peak current > 300 mA (IB2 − D7 = 1) − normal load (D5 = 0) D4 Channel 2 Turn-on diagnostic (D4 = 0) Permanent diagnostic (D4 = 1) D3 Channel 2 Normal load (D3 = 0) Short load (D3 = 1) D2 Channel 2 Turn-on diag: No open load (D2 = 0) Open load detected (D2 = 1) Offset diag: No output offset (D2 = 0) Output offset detected (D2 = 1) D1 Channel 2 No short to VCC (D1 = 0) Short to VCC (D1 = 1) D0 Channel 2 No short to GND (D0 = 0) Short to GND (D0 = 1) Note 12: DBx (D5) is effective only at the time of “Current detection enable”.
DB3 Diagnostic Byte: Bit D7 Stand-by status ( = IB2 − D4) D6 Diagnostic status ( = IB1 − D6) D5 Channel 3 current detection Output peak current < 250 mA (IB2 − D7 = 0) − open load (D5 = 1) Output peak current < 100 mA (IB2 − D7 = 1) − open load (D5 = 1) Output peak current > 500 mA (IB2 − D7 = 0) − normal load (D5 = 0) Output peak current > 300 mA (IB2 − D7 = 1) − normal load (D5 = 0) D4 Channel 3 Turn-on diagnostic (D4 = 0) Permanent diagnostic (D4 = 1) D3 Channel 3 Normal load (D3 = 0) Short load (D3 = 1) D2 Channel 3 Turn-on diag: No open load (D2 = 0) Open load detected (D2 = 1) Offset diag: No output offset (D2 = 0) Output offset detected (D2 = 1) D1 Channel 3 No short to VCC (D1 = 0) Short to VCC (D1 = 1) D0 Channel 3 No short to GND (D0 = 0) Short to GND (D0 = 1)
DB4 Diagnostic Byte: Bit D7 X D6 X D5 Channel 4 current detection Output peak current < 250 mA (IB2 − D7 = 0) − open load (D5 = 1) Output peak current < 100 mA (IB2 − D7 = 1) − open load (D5 = 1) Output peak current > 500 mA (IB2 − D7 = 0) − normal load (D5 = 0) Output peak current > 300 mA (IB2 − D7 = 1) − normal load (D5 = 0) D4 Channel 4 Turn-on diagnostic (D4 = 0) Permanent diagnostic (D4 = 1) D3 Channel 4 Normal load (D3 = 0) Short load (D3 = 1) D2 Channel 4 Turn-on diag: No open load (D2 = 0) Open load detected (D2 = 1) Offset diag: No output offset (D2 = 0) Output offset detected (D2 = 1) D1 Channel 4 No short to VCC (D1 = 0) Short to VCC (D1 = 1) D0 Channel 4 No short to GND (D0 = 0) Short to GND (D0 = 1) Note 13: DBx (D5) is effective only at the time of “Current detection enable”.
- Caution for use Turn on diagnosis mode The comparator detect the voltage between speaker both ends. If that voltage is larger, this detector judges “output load open”, while, if it is smaller, this detector judges the “short load”. But, in case of output shorted to V CC or shorted to GND condition, the voltage between speaker will be surely changed. Therefore, this system can not present exact information, for example, "Short to VCC" and "Short load" are showed though output is shorted to Vcc but no short load. In this case, the result as DET2 shall be dropped or ignored and DET1 is effective as DET1 is prior to DET2. Permanent diagnosis mode Please arrange to read all self-diagnosis functions twice or more and apply judgment in order to avoid false triggering. <Since the first diagnostic result has low confidence, please diagnose 2 times or more.> Automatic turn on muting The automatic turn on muting operates from when the turn on write command is sent, it is continued until the Pin 10 ripple pin voltage reaches to about the 8VF=5.6V . During this automatic turn on muting operation, output sound can not appear even if the mute off write command is sent because the internal muting circuit operates. The automatic turn on muting operation period is MIN=xx msec, MAX=zz msec in case of C2 (Pin 10) = 10 uF, Vcc=9 to 18V and Tj = -40 to 150 degrees condition. When the Turn on diagnosis is enable, the automatic muting period starts after Turn on diag cycle period. This period is in proportion to the value of the C2 so that the characteristic of C2 shall be had a care, for example, temperature, variation and so on. AMP DET circuit 1 (VCC/GND short) DET circuit 2 (short/open) AMP OUT OUT SP <Output stage> AMP AMP S 5 V I = constant current Comparator <RL short/open detector, at TURN-on mode> Figure 11 Automatic Turn on Muting Timing Chart WRITE DATA Pin10 ripple pin Voltage=5.6V → Turn ON diagnosis enable Turn ON diagnosis defeat Automatic Turn ON Muting at Turn on diag defeat Possible to play music if the mute off write command is sent at Turn on diag defeat Automatic Turn ON Muting at Turn on diag enable Possible to play music if the mute off write command is sent at Turn on diag enable
Examples of Bytes Sequence 1 - Turn-On Diagnostic - Write Operation Start Address byte with D0 = 0 ACK Sub-address D0 = 1 ACK IB with D6 = 1 ACK IB2 ACK STOP Note 14: Auto increment 2 - Turn-On Diagnostic - Read Operation Start Address byte with D0 = 1 ACK DB1 ACK DB2 ACK DB3 ACK DB4 ACK STOP 3a - Turn-On of the Power Amplifier with 26dB Gain, Mute On, Diagnostic Defeat. Start Address byte with D0 = 0 ACK Sub-address D0 = 1 ACK IB 1 ACK IB2 ACK STOP X0X0000X XXX1X0XX Note 15: Auto increment 3b - Turn-Off of the Power Amplifier Start Address byte with D0 = 0 ACK Sub-address D0 = 1 ACK IB 1 ACK IB2 ACK STOP X0XXXXXX XXX0XXXX Note 16: Auto increment 4 - Offset Detection Procedure Enable Start Address byte with D0 = 0 ACK Sub-address D0 = 1 ACK IB 1 ACK IB2 ACK STOP XX1XX11X XXX1X0XX Note 17: Auto increment 5 - Offset detection procedure stop and reading operation (the results are valid only for the offset detection bits (D2 of the bytes DB1, DB2, DB3, DB4). Start Address byte with D0 = 1 ACK DB1 ACK DB2 ACK DB3 ACK DB4 ACK STOP
I2C Bus control format outline The BUS control format of TB2912HQ is based on the Philips I2C bus control format. Data Transmission Format Note 18: It is transmitting, without forgetting. P conditions. (1) Start conditions & stop conditions (2) Bit transmission (3) Acknowledgement Purchase of TOSHIBA I2C components conveys a license under the Philips I2C Patent Rights to use these components in an I2C system, provided that the system conforms to the I2C Standard Specification as defined by Philips. A7 A6 A5 A4 A3 A2 A1 A0 R/ W 1 1 0 1 1 0 0 X S Slave address 0 A Sub address A Data A P MSB 7 bit MSB 8 bit MSB 8 bit S: Start conditions P: Stop conditions A: Acknowledgement SCL S SDA P Start conditions Sto p conditions SDA can not be changed SDA can be changed SDA SCL High impedance S High impedance SDA from a master SCL from a master Start conditions
TB2912HQ I2C Bus Transmission Format (1) Write mode In addition to usual transmission, it corresponds to continuation transmission and the auto increment mode as a transmission format. After a transmission end, in case data transmission is newly, it is necessary to open the term beyond 1 clock. 1) Continuation transmission (An address to change is specified. At this time, MSB of a sub-address is set as 0.) 2) Auto increment (Sub address are set to increment from N one by one. MSB of a sub-address is set as 1.) (2) Read mode The slave address became the read mode by changing the 8 Bit of the slave address from 0 to 1. The data output from TB2912HQ starts after the micro controller receives the ACK 1 bit which follows a slave address. Stop condition are shown in the under the map. The micro controller shall send the stop condition P after it sent the reversed Acknowledge (high) in case of the read mode finished. The data transmission became not available condition if the micro controller intended to send the stop condition P expect for this procedure because this IC occupies the data bus until the micro controller send the start conditions again. S Slave ADD 0 A Sub ADD a A DATA 7 to 0 A Sub ADD b A DATA 7 to 0 A Sub ADD x A DATA 7 to 0 P S Slave ADD (R) A DATA1 A DATA2 A DATA3 A DATA4 A P DATA 7 to 0 P (sub ADD N + m) S Slave ADD 0 A (sub ADD N)&80h A DATA 7 to 0 A DATA 7 to 0 A DATA 7 to 0 A (sub ADD N + 1) (sub ADD N + 2)
Absolute Maximum Ratings (Ta = 25°C) Characteristics Symbol Rating Unit Peak supply voltage (0.2 s) V CC (surge) 50 V DC supply voltage V CC (DC) 28 V Operation supply voltage V CC (opr) 18 V Output current (peak) I O (peak) 9 A Power dissipation PD (Note 19) 125 W Operation temperature T opr −40 to 85 °C Storage temperature T stg −55 to 150 °C Note 19: Package thermal resistance θj-T = 1°C/W (typ.) (Ta = 25°C, with infinite heat sink) The absolute maximum ratings of a semiconductor device are a set of specified parameter values, which must not be exceeded during operation, even for an instant. If any of these rating would be exceeded during operation, the device electrical characteristics may be irreparably altered and the reliability and lifetime of the device can no longer be guaranteed. Moreover, these operations with exceeded ratings may cause break down, damage and/or degradation to any other equipment. Applications using the device should be designed such that each absolute maximum rating will never be exceeded in any operating conditions. Before using, creating and/or producing designs, refer to and comply with the precautions and conditions set forth in this documents.
Electrical Characteristics
(unless otherwise specified, VCC = 13.2 V, f = 1 kHz, RL = 4 Ω, Ta = 25°C) Characteristics Symbol Test Circuit Test Condition Min Typ. Max Unit Quiescent current I CCQ ⎯ VIN = 0 ⎯ 200 300 mA POUT MAX (1) ⎯ VCC = 14.4 V, max POWER ⎯ 41 ⎯ POUT MAX (2) ⎯ VCC = 13.7 V, max POWER ⎯ 37 ⎯ POUT (1) ⎯ VCC = 14.4 V, THD = 10% 24 27 ⎯ Output power POUT (2) ⎯ THD = 10% ⎯ 23 ⎯ W POUT MAX (3) ⎯ VCC = 14.4 V, max POWER ⎯ 70 ⎯ POUT MAX (4) ⎯ VCC = 13.7 V, max POWER ⎯ 64 ⎯ POUT (3) ⎯ VCC = 14.4 V, THD = 10% 42 46 ⎯ Output power (RL = 2 Ω) POUT (4) ⎯ THD = 10% ⎯ 39 ⎯ W THD (1) ⎯ POUT = 5 W ⎯ 0.015 0.1 Total harmonic distortion THD (2) ⎯ Vo = 2 Vrms, GV = 12dB ⎯ 0.01 0.1 GV (1) ⎯ VOUT = 0.775 Vrms 25 26 27 Voltage gain GV (2) ⎯ VOUT = 0.775 Vrms, GV = 12dB 11 12 13 dB Voltage gain ratio ∆GV ⎯ VOUT = 0.775 Vrms −1 0 1 dB Vno (1) ⎯ Rg = 0 Ω, DIN45405 ⎯ 100 ⎯ Vno (2) ⎯ Rg = 0 Ω, BW = 20 Hz to 20 kHz ⎯ 90 200 Output noise voltage Vno (3) ⎯ Rg = 0 Ω, BW = 20 Hz to 20 kHz GV = 12dB ⎯ 30 50 µVrms Ripple rejection ratio R.R. ⎯ fripple = 100 Hz, Rg = 620 Ω Vrip = 0.775 Vrms 40 50 ⎯ dB Cross talk C.T. ⎯ Rg = 620 Ω VOUT = 0.775 Vrms ⎯ 65 ⎯ dB Output offset voltage VOFFSET ⎯ ⎯ − 150 0 150 mV Input resistance RIN ⎯ ⎯ ⎯ 90 ⎯ kΩ Standby current ISB ⎯ Stand-by condition (Pin16 at 0V) ⎯ 1 10 µA VSM H ⎯ For operation, mute enable 7.0 ⎯ VCC Stand by & mute control voltage VSM L ⎯ For mute, stand by OFF 0 ⎯ 5.0 V Mute attenuation ATT M ⎯ Mute: ON VOUT = 7.75 Vrms → Mute: OFF 80 90 ⎯ dB CD (1) ⎯ Low (01H D = 0) ⎯ 1 2.5 Clip det THD level CD (2) ⎯ High (01H D = 1) 5 10 15 Note 20: ISB specification will be decided to after final evaluation on tolerance spls.
Diagnosis/Bus Specification Characteristics Test Condition Min Typ. Max Unit Turn on diagnosis (power amplifier mode) Short to GND det. Under stand-by condition ⎯ ⎯ 1.2 V Short to VCC det. VCC − 1.2 ⎯ ⎯ V Shorted load ⎯ ⎯ 0.5 Ω Open load 85 ⎯ ⎯ Ω Normal load 1.5 ⎯ 45 Ω Turn on diagnosis (line driver mode) Short to GND det. Under stand-by condition ⎯ ⎯ 1.2 V Short to VCC det. VCC − 1.2 ⎯ ⎯ V Shorted load ⎯ ⎯ 2 Ω Open load 330 ⎯ ⎯ Ω Normal load 6 ⎯ 180 Ω Permanent diagnosis (power amplifier and line driver mode) Short to GND det. Power amplifier in mute or play ⎯ ⎯ 1.2 V Short to VCC det. VCC − 1.2 ⎯ ⎯ V Shorted load Power amp mode only ⎯ 0.5 ⎯ Ω Offset detection Power amplifier in play (no signal) ⎯ + /−2 ⎯ V Current detector threshold 1 250 500 mA Current detector threshold 2 100 300 mA I2C bus interface Clock frequency ⎯ 400 ⎯ kHz
Components in the test circuits are only used to obtain and confirm the device characteristics. These components and circuits do not warrant to prevent the application equipment from malfunction or failure. Ripple IN1 Out1 (+) TAB VCC2 VCC1 C5: 3900 µF C3: 0.1 µF C2: 10 µF C1: 0.22 µF RL = 4 Ω PW-GND1 Out1 (−) IN2 Out2 (+) C1: 0.22 µF RL = 4 Ω PW-GND2 Out2 (−) IN3 Out3 (+) C1: 0.22 µF RL = 4 Ω PW-GND3 Out3 (−) IN4 Out4 (+) C1: 0.22 µF RL = 4 Ω PW-GND4 Out4 (−) C4: 1 µF & Mute
Output power P OUT ( W ) THD – POUT (ch1) Total harmonic distortion THD (%) Output power P OUT (W) Output power P OUT (W) Output power P OUT ( W ) THD – POUT (ch2) Total harmonic distortion THD (%) THD – POUT (ch4) Total harmonic distortion THD (%) THD – POUT (ch3) Total harmonic distortion THD (%) 0.1 100 0.001 0.3 1 30 0.5 10 35 5 0 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 GV = 26dB RL = 4 Ω Filter
100 Hz : to 30 kHz
1kHz : 400 Hz to 30 kHz 10 kHz : 400 Hz to 20 kHz : 400 Hz to f = 1 kHz 100 Hz 10 kHz 20 kHz 0.1 100 0.001 0.3 1 30 0.5 10 35 5 0 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 GV = 26dB RL = 4 Ω Filter 1kHz : 400 Hz to 30 kHz 10 kHz : 400 Hz to 20 kHz : 400 Hz to f = 1 kHz 100 Hz 10 kHz 20 kHz 0.1 100 0.001 0.3 1 30 0.5 10 35 5 0 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 GV = 26dB RL = 4 Ω Filter 1kHz : 400 Hz to 30 kHz 10 kHz : 400 Hz to 20 kHz : 400 Hz to f = 1 kHz 100 Hz 10 kHz 20 kHz 0.1 100 0.001 0.3 1 30 0.5 10 35 5 0 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 VCC = 13.2 V RL = 4 Ω 測定 ch のみ入力 Filter
100 Hz : ~300 kHz
1kHz : 400 Hz~30 kHz 10 kHz : 400 Hz~ 30 kHz : 400 Hz~ 0.1 100 0.001 0.3 1 30 0.5 10 35 5 0 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 GV = 26dB RL = 4 Ω Filter 1kHz : 400 Hz to 30 kHz 10 kHz : 400 Hz to 20 kHz : 400 Hz to f = 1 kHz 100 Hz 10 kHz 20 kHz
Output power P OUT (W) THD – POUT (ch1) Total harmonic distortion THD (%) Output power P OUT (W) Output power P OUT (W) Output power P OUT (W) THD – POUT (ch2) Total harmonic distortion THD (%) THD – POUT (ch4) Total harmonic distortion THD (%) THD – POUT (ch3) Total harmonic distortion THD (%) 0.01 10 0.001 0.03 0.1 3 10.3 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 GV = 26dB RL = 4 Ω f = 1 kHz Filter
400 Hz to 30 kHz
VCC = 9.0 V 13.2 V 16.0 V 0.01 10 0.001 0.03 0.1 3 10.3 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 GV = 26dB RL = 4 Ω f = 1 kHz Filter VCC = 9.0 V 13.2 V 16.0 V 0.01 10 0.001 0.03 0.1 3 10.3 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 GV = 26dB RL = 4 Ω f = 1 kHz Filter VCC = 9.0 V 13.2 V 16.0 V 0.01 10 0.001 0.03 0.1 3 10.3 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 GV = 26dB RL = 4 Ω f = 1 kHz Filter VCC = 9.0 V 13.2 V 16.0 V
Total harmonic distortion THD (%) Frequency f (Hz) muteATT – f Mute attenuation muteATT (dB) Frequency f (Hz) R.R. – f Ripple rejection ratio R.R. (dB) Frequency f (Hz) G V – f Voltage gain G V (dB) Frequency f (Hz) THD – f VCC = 13.2 V RL = 4 Ω RG = 620 Ω Vrip = 0.775 Vrms (0dBm) 10010 100 k −80 1 k 10 k −60 −40 −20 3ch 2ch 4ch 1ch VCC = 13.2 V RL = 4 Ω POUT = 5 W No filter 10010 100 k 0.001 1 k 10 k 0.003 0.01 0.03 0.1 0.3 3ch 1ch 4ch 2ch VCC = 13.2 V RL = 4 Ω VOUT = 7.75 Vrms (20dBm) 100 10 100 k −120 1 k 10 k −100 −80 −60 −40 −20 ch1 VCC = 13.2 V RL = 4 Ω VOUT = 0.775 Vrms (0dBm) 100 10 100 k 1 k 10 k ch1 to ch4
Quiescent Current I CCQ (mA) Output power P OUT (W) Input voltage V IN (Vrms) V IN – POUT (ch1) Output power P OUT (W) Input voltage V IN ( V r m s ) V IN – POUT (ch2) Output power P OUT (W) Input voltage V IN (Vrms) V IN – POUT (ch3) Output power P OUT (W) Input voltage V IN ( V r m s ) V IN – POUT (ch4) Supply voltage V CC (V) I CCQ –VCC Ambient temperature Ta (°C) P D MAX – Ta Allowable power dissipation P D MAX (W) (1) (2) (3) 250 150 120 100 100 50 125 (1) Infinite heat sink RθJC = 1°C/W (2) Heat sink (R θHS = 3.5°C/W) RθJC + RθHS = 4.5°C/W (3) No heat sink RθJA = 39°C/W 150 0 5 10 15 25 30 20 100 200 250 VIN = 0 RL = ∞ 0 2 4 6 8 10 VCC = 13.2 V RL = 4 Ω No filter 100 Hz 10 kHz f = 20 kHz 1 kHz 0 2 4 6 8 10 VCC = 13.2 V RL = 4 Ω No filter 100 Hz 10 kHz f = 20 kHz 1 kHz 0 2 4 6 8 10 VCC = 13.2 V RL = 4 Ω No filter 100 Hz 10 kHz f = 20 kHz 1 kHz 0 2 4 6 8 10 VCC = 13.2 V RL = 4 Ω No filter 1 kHz 100 Hz 10 kHz f = 20 kHz
Cross talk C.T. (dB) Frequency f (Hz) C.T. – f (ch1) Cross talk C.T. (dB) Frequency f (Hz) C.T. – f (ch2) Cross talk C.T. (dB) Frequency f (Hz) C.T. – f (ch3) Cross talk C.T. (dB) Frequency f (Hz) C.T. – f (ch4) Signal source resistance R g ( Ω) V NO – Rg Output power P OUT (W) P D – POUT Power dissipation P D (W) Output noise voltage V NO ( µVrms) VCC = 13.2 V RL = 4 Ω f = 1 kHz Filter to 20 kHz 100 10 100 k 1 k 10 k 100 200 300 ch1 to ch4 10010 100 k −80 1 k 10 k −60 −40 −20 −100 ch1 ch3 VCC = 13.2 V RL = 4 Ω f = 1 kHz VOUT = 0.775 Vrms (0dBm) RG = 620 Ω ch4 100 10 100 k −80 1 k 10 k −60 −40 −20 −100 ch4 ch2 VCC = 13.2 V RL = 4 Ω f = 1 kHz VOUT = 0.775 Vrms (0dBm) RG = 620 Ω ch1 10010 100 k −80 1 k 10 k −60 −40 −20 −100 ch3 ch2 VCC = 13.2 V RL = 4 Ω f = 1 kHz VOUT = 0.775 Vrms (0dBm) RG = 620 Ω ch1 100 10 100 k −80 1 k 10 k −60 −40 −20 VCC = 13.2 V RL = 4 Ω f = 1 kHz VOUT = 0.775 Vrms (0dBm) RG = 620 Ω −100 ch2 ch3 ch4 0 5 10 15 25 20 f = 1 kHz RL = 4 Ω 4ch drive 9.0 V 13.2 V 16 V 18 V
Output power P OUT (W) THD – POUT (ch1) Total harmonic distortion THD (%) Output power P OUT (W) Output power P OUT (W) Output power P OUT (W) THD – POUT (ch2) Total harmonic distortion THD (%) THD – POUT (ch4) Total harmonic distortion THD (%) THD – POUT (ch3) Total harmonic distortion THD (%) 0.01 10 0.001 0.03 0.1 3 10.3 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 GV = 26dB RL = 2 Ω f = 1 kHz Filter
400 Hz~30 kHz
VCC = 9.0 V 13.2 V 16.0 V 0.01 10 0.001 0.03 0.1 3 10.3 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 GV = 26dB RL = 2 Ω f = 1 kHz Filter VCC = 9.0 V 13.2 V 16.0 V 0.01 10 0.001 0.03 0.1 3 10.3 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 GV = 26dB RL = 2 Ω f = 1 kHz Filter VCC = 9.0 V 13.2 V 16.0 V 0.01 10 0.001 0.03 0.1 3 10.3 0.01 0.1 0.003 0.005 0.03 0.05 0.3 0.5 100 GV = 26dB RL = 2 Ω f = 1 kHz Filter VCC = 9.0 V 13.2 V 16.0 V
Output power P OUT (W) P D – POUT Power dissipation P D (W) 0 5 10 15 25 20 100 f = 1 kHz RL = 2 Ω 4ch drive 9.0 V 13.2 V 16 V
Weight: 7.7 g (typ.)
- Use an appropriate power supply fuse to ensure that a large current does not continuously flow in case of over current and/or IC failure. The IC will fully break down when used under conditions that exceed its absolute maximum ratings, when the wiring is routed improperly or when an abnormal pulse noise occurs from the wiring or load, causing a large current to continuously flow and the breakdown can lead smoke or ignition. To minimize the effects of the flow of a large current in case of breakdown, appropriate settings, such as fuse capacity, fusing time and insertion circuit location, are required.
- If your design includes an inductive load such as a motor coil, incorporate a protection circuit into the design to prevent device malfunction or breakdown caused by the current resulting from the inrush current at power ON or the negative current resulting from the back electromotive force at power OFF. For details on how to connect a protection circuit such as a current limiting resistor or back electromotive force adsorption diode, refer to individual IC datasheets or the IC databook. IC breakdown may cause injury, smoke or ignition.
- Use a stable power supply with ICs with built-in protection functions. If the power supply is unstable, the protection function may not operate, causing IC breakdown. IC breakdown may cause injury, smoke or ignition.
- Carefully select external components (such as inputs and negative feedback capacitors) and load components (such as speakers), for example, power amp and regulator. If there is a large amount of leakage current such as input or negative feedback condenser, the IC output DC voltage will increase. If this output voltage is connected to a speaker with low input withstand voltage, overcurrent or IC failure can cause smoke or ignition. (The over current can cause smoke or ignition from the IC itself.) In particular, please pay attention when using a Bridge Tied Load (BTL) connection type IC that inputs output DC voltage to a speaker directly.
- Over current Protection Circuit Over current protection circuits (referred to as current limiter circuits) do not necessarily protect ICs under all circumstances. If the Over current protection circuits operate against the over current, clear the over current status immediately. Depending on the method of use and usage conditions, such as exceeding absolute maximum ratings can cause the over current protection circuit to not operate properly or IC breakdown before operation. In addition, depending on the method of use and usage conditions, if over current continues to flow for a long time after operation, the IC may generate heat resulting in breakdown.
- Thermal Shutdown Circuit Thermal shutdown circuits do not necessarily protect ICs under all circumstances. If the Thermal shutdown circuits operate against the over temperature, clear the heat generation status immediately. Depending on the method of use and usage conditions, such as exceeding absolute maximum ratings can cause the thermal shutdown circuit to not operate properly or IC breakdown before operation.
- Heat Radiation Design When using an IC with large current flow such as power amp, regulator or driver, please design the device so that heat is appropriately radiated, not to exceed the specified junction temperature (Tj) at any time and condition. These ICs generate heat even during normal use. An inadequate IC heat radiation design can lead to decrease in IC life, deterioration of IC characteristics or IC breakdown. In addition, please design the device taking into considerate the effect of IC heat radiation with peripheral components.
- Installation to Heat Sink Please install the power IC to the heat sink not to apply excessive mechanical stress to the IC. Excessive mechanical stress can lead to package cracks, resulting in a reduction in reliability or breakdown of internal IC chip. In addition, depending on the IC, the use of silicon rubber may be prohibited. Check whether the use of silicon rubber is prohibited for the IC you intend to use, or not. For details of power IC heat radiation design and heat sink installation, refer to individual technical datasheets or IC databooks.
RESTRICTIONS ON PRODUCT USE 060116EBF
- The information contained herein is subject to change without notice. 021023_D
- TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utiliz ing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handli ng Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc. 021023_A
- The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk. 021023_B
- The products described in this document shall not be used or embedded to any downstream products of which manufacture, use and/or sale are prohibited under any applicable laws and regulations. 060106_Q
- The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TOSHIBA or others. 021023_C
- The products described in this document are subject to the foreign exchange and foreign trade laws. 021023_E
- This product generates heat during normal operation. However, substandard performance or malfunction may cause the product and its peripherals to reach abnormally high temperatures. The product is often the final stage (the external output stage) of a circuit. Substandard performance or malfunction of the destination device to which the circuit supplies output may cause damage to the circuit or to the product. 030619_R About solderability, following conditions were confirmed
- Solderability (1) Use of Sn-37Pb solder Bath
- solder bath temperature = 230°C
- dipping time = 5 seconds
- the number of times = once
- use of R-type flux (2) Use of Sn-3.0Ag-0.5Cu solder Bath
- solder bath temperature = 245°C
- dipping time = 5 seconds
- the number of times = once