© Panasonic Corporation 2019industrial.panasonic.com/ac/e/ AECTB5E 2019062019.06 TOGGLE TYPES

FEATURES

  • Series includes rocker and push-button switches.
  • Sealed type available for use in different environments.
  • Rubber cap also available in silicon type for excellent weather resistance. ASSORTMENT Notes: *1: Only standard type *2: Only wire leads type These switches are only for Industrial use. Do not use any other applications. (ex. home use) 12 dia. Toggle Push- button Square hole Rocker Kind of actuator Standard type Sealed type Number of pole Shape of terminal Panel- sealed type Terminal- sealed type Wire leads type 1P 2P 3P 4P Solder terminal Screw terminal .250 Quick- connect terminal Wire lead Toggle type Available Available Available Available Available Available Available*1 Available*1 Available Available Available*1 Available*2 Rocker type Available Available Available Available Available Available — — Available Available — Available*2 Push-button type Available Available — — Available Available — — Available Available — — ■Standard type 1) Solder terminal and .250 Quick-connect terminal Number of poles Kind of operation < >: Momentary position Solder terminal .250 Quick-connect terminal Part No. Part No. 1-pole ON-OFF T115A-F T115A-AF ON-ON T115D-F T115D-AF ON-OFF-ON T115E-F T115E-AF ON-<ON> T115F-F T115F-AF <ON>-OFF-<ON> T115G-F T115G-AF ON-OFF-<ON> T115H-F T115H-AF 2-pole ON-OFF T215K-F T215K-AF ON-ON T215N-F T215N-AF ON-OFF-ON T215P-F T215P-AF ON-<ON> T215R-F T215R-AF <ON>-OFF-<ON> T215S-F T215S-AF ON-OFF-<ON> T215T-F T215T-AF 3-pole ON-OFF T315K-F T315K-AF ON-ON T315N-F T315N-AF ON-OFF-ON T315P-F T315P-AF 4-pole ON-OFF T415K-F T415K-AF ON-ON T415N-F T415N-AF ON-OFF-ON T415P-F T415P-AF Note: Standard installation accessories are included with the product. Automation Controls Catalog ー 1 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 Note: Of the standard installation accessories that come with the product, the front hex nut and lock washer are included. Note: Of the standard installation accessories that come with the product, the front hex nut and lock washer are included. Note: Standard installation accessories are included with the product. 2) Screw terminal Number of poles Kind of operation < >: Momentary position Screw terminal Part No. 1-pole ON-OFF T115A-SF ON-ON T115D-SF ON-OFF-ON T115E-SF ON-<ON> T115F-SF <ON>-OFF-<ON> T115G-SF ON-OFF-<ON> T115H-SF 2-pole ON-OFF T215K-SF ON-ON T215N-SF ON-OFF-ON T215P-SF ON-<ON> T215R-SF <ON>-OFF-<ON> T215S-SF ON-OFF-<ON> T215T-SF 3-pole ON-OFF T315K-SF ON-ON T315N-SF ON-OFF-ON T315P-SF 4-pole ON-OFF T415K-SF ON-ON T415N-SF ON-OFF-ON T415P-SF ■Panel-sealed type 1) Solder terminal Number of poles Kind of operation < >: Momentary position Solder terminal Part No. 1-pole ON-OFF TP115A-F ON-ON TP115D-F ON-OFF-ON TP115E-F ON-<ON> TP115F-F <ON>-OFF-<ON> TP115G-F ON-OFF-<ON> TP115H-F 2-pole ON-OFF TP215K-F ON-ON TP215N-F ON-OFF-ON TP215P-F ON-<ON> TP215R-F <ON>-OFF-<ON> TP215S-F ON-OFF-<ON> TP215T-F 2) Screw terminal Number of poles Kind of operation < >: Momentary position Screw terminal Part No. 1-pole ON-OFF TP115A-SF ON-ON TP115D-SF ON-OFF-ON TP115E-SF ON-<ON> TP115F-SF <ON>-OFF-<ON> TP115G-SF ON-OFF-<ON> TP115H-SF 2-pole ON-OFF TP215K-SF ON-ON TP215N-SF ON-OFF-ON TP215P-SF ON-<ON> TP215R-SF <ON>-OFF-<ON> TP215S-SF ON-OFF-<ON> TP215T-SF ー 2 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 Note: 1. Of the standard installation accessories that come with the part, the front hex nut and lock washer are included. 2. 300 V vinyl wire (VSF, thick: 2 mm2, length: 200 mm) is used. Please inquire about type and different length of lead wire. Note: Of the standard installation accessories that come with the product, the front hex nut and lock washer are included. 1) Solder terminal 2) Screw terminal ■Terminal-sealed type Number of poles Kind of operation < >: Momentary position Solder terminal Part No. 1-pole ON-OFF TD115A-F ON-ON TD115D-F ON-OFF-ON TD115E-F ON-<ON> TD115F-F <ON>-OFF-<ON> TD115G-F ON-OFF-<ON> TD115H-F 2-pole ON-OFF TD215K-F ON-ON TD215N-F ON-OFF-ON TD215P-F ON-<ON> TD215R-F <ON>-OFF-<ON> TD215S-F ON-OFF-<ON> TD215T-F Number of poles Kind of operation < >: Momentary position Screw terminal Part No. 1-pole ON-OFF TD115A-SF ON-ON TD115D-SF ON-OFF-ON TD115E-SF ON-<ON> TD115F-SF <ON>-OFF-<ON> TD115G-SF ON-OFF-<ON> TD115H-SF 2-pole ON-OFF TD215K-SF ON-ON TD215N-SF ON-OFF-ON TD215P-SF ON-<ON> TD215R-SF <ON>-OFF-<ON> TD215S-SF ON-OFF-<ON> TD215T-SF Note: Of the standard installation accessories that come with the part, the front hex nut and lock washer are included. ■Wire lead type Number of poles Kind of operation < >: Momentary position Wire lead type Part No. 1-pole ON-OFF TC115A-F ON-ON TC115D-F ON-OFF-ON TC115E-F ON-<ON> TC115F-F <ON>-OFF-<ON> TC115G-F ON-OFF-<ON> TC115H-F 2-pole ON-OFF TC215K-F ON-ON TC215N-F ON-OFF-ON TC215P-F ON-<ON> TC215R-F <ON>-OFF-<ON> TC215S-F ON-OFF-<ON> TC215T-F ー 3 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 Note: A selling unit of each accessory is 10 pieces. 1) Installation accessories (Repair parts)

  • Using the different rubber caps We recommend silicon rubber and EP rubber caps for the following applications. ■Accessories Notes: 1. The asterisk “∗” in the part number WD1811∗ for the silicon rubber type rubber cap is where the letter representing the color should be inserted. (B: black; R: red; Z: grey; Y: yellow; G: green.) 2. EP rubber cap is available in black only. 3. Letters on the display panel are aluminum colored and the area surrounding the letters is black. 4. Indication plate and rubber cap are compatible with the T-15 series switch, T-10 series switch, and T-03/T-06 series switches (when plate thickness is 2.7 mm or less). 5. Applicable EP rubber type switches are only available in ON-OFF, ON-ON, ON <- ON>, and <ON>-OFF <- ON>. “< >”: Momentary position ■Standard type Product name Standard installation accessories Optional installation accessories Front hex nut (Nickel plated) Back hex nut (Uni-chrome plated) Keying washer Lock washer Front Knurl nut (Nickel plated) Dimensions (Unit: mm) (16.17) 2.3 M12 x 1 (16.17) 2.3 M12 x 1 2.8 18.2 dia. 12.3 dia. 2.4 9.7 15.6 dia. 12.3 dia. 0.5 1 15 dia. 2.4 M12 x 1 Part No. AJ3081 AJ3082 AJ3083 AJ3084 AJ3080 1) Silicon rubber type
  • When it is necessary to differentiate by color.
  • When using in applications that require resistance to heat and cold. Ambient temperature: –25°C to +85°C (EP rubber type is 0°C to +40°C.)
  • When compactness is required. 2) EP rubber type When cost is the primary consideration. 2) Accessories (Option) Product name Indication plate (aluminum) (Note 3) Rubber cap (Note 1, 2, 4, 5) ON-OFF ON-ON EP rubber type Silicone rubber type Dimensions (Unit: mm) 10 dia. 24.5 21 dia. M12 Part No. WD1901 WD1902 WD1911 WD1811* 12.3 dia. 30 1.3 1.5 0.8 0.8 17 12.3 dia. 30 1.3 1.5 0.8 0.8 17 8 dia. 24.5 18 dia. M12 8.6 ROCKER TYPES 1) Solder terminal, without indication on actuator Number of poles Kind of operation < >: Momentary position Solder terminal Part No. 1-pole ON-OFF TR115A-*F ON-ON TR115D-*F ON-OFF-ON TR115E-*F ON-<ON> TR115F-*F ON-OFF-<ON> TR115H-*F 2-pole ON-OFF TR215K-*F ON-ON TR215N-*F ON-OFF-ON TR215P-*F ON-<ON> TR215R-*F ON-OFF-<ON> TR215T-*F Note: Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) ー 4 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 Note: Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) Note: Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) 2) Screw terminal, without indication on actuator 3) Solder terminal, with ON-OFF indication on actuator ■Panel-sealed type Number of poles Kind of operation < >: Momentary position Screw terminal Part No. 1-pole ON-OFF TR115A-S*F ON-ON TR115D-S*F ON-OFF-ON TR115E-S*F ON-<ON> TR115F-S*F ON-OFF-<ON> TR115H-S*F 2-pole ON-OFF TR215K-S*F ON-ON TR215N-S*F ON-OFF-ON TR215P-S*F ON-<ON> TR215R-S*F ON-OFF-<ON> TR215T-S*F Number of poles Kind of operation Solder terminal Part No. 1-pole ON-OFF TR115A-*F 2-pole ON-OFF TR215K-*F Note: Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) Note: Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) Note: Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) 4) Screw terminal, with ON-OFF indication on actuator Number of poles Kind of operation Screw terminal Part No. 1-pole ON-OFF TR115A-S*F 2-pole ON-OFF TR215K-S*F 1) Solder terminal, without indication on actuator Number of poles Kind of operation < >: Momentary position Solder terminal Part No. 1-pole ON-OFF TRP115A-*F ON-ON TRP115D-*F ON-OFF-ON TRP115E-*F ON-<ON> TRP115F-*F ON-OFF-<ON> TRP115H-*F 2-pole ON-OFF TRP215K-*F ON-ON TRP215N-*F ON-OFF-ON TRP215P-*F ON-<ON> TRP215R-*F ON-OFF-<ON> TRP215T-*F 2) Screw terminal, without indication on actuator Number of poles Kind of operation < >: Momentary position Screw terminal Part No. 1-pole ON-OFF TRP115A-S*F ON-ON TRP115D-S*F ON-OFF-ON TRP115E-S*F ON-<ON> TRP115F-S*F <ON>-OFF-<ON> TRP115G-S*F ON-OFF-<ON> TRP115H-S*F 2-pole ON-OFF TRP215K-S*F ON-ON TRP215N-S*F ON-OFF-ON TRP215P-S*F ON-<ON> TRP215R-S*F <ON>-OFF-<ON> TRP215S-S*F ON-OFF-<ON> TRP215T-S*F ー 5 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 Note: Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) Note: Please specify the actuator color by replacing the asterisk “∗” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) Note: Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) Note: Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) Note: Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) 3) Solder terminal, with ON-OFF indication on actuator ■Terminal-sealed type 1) Solder terminal, without indication on actuator 2) Screw terminal, without indication on actuator Number of poles Kind of operation Solder terminal Part No. 1-pole ON-OFF TRP115A-*1F 2-pole ON-OFF TRP215K-*1F 4) Screw terminal, with ON-OFF indication on actuator Number of poles Kind of operation Screw terminal Part No. 1-pole ON-OFF TRP115A-S*1F 2-pole ON-OFF TRP215K-S*1F Number of poles Kind of operation < >: Momentary position Solder terminal Part No. 1-pole ON-OFF TRD115A-*F ON-ON TRD115D-*F ON-OFF-ON TRD115E-*F ON-<ON> TRD115F-*F ON-OFF-<ON> TRD115H-*F 2-pole ON-OFF TRD215K-*F ON-ON TRD215N-*F ON-OFF-ON TRD215P-*F ON-<ON> TRD215R-*F ON-OFF-<ON> TRD215T-*F Number of poles Kind of operation < >: Momentary position Screw terminal Part No. 1-pole ON-OFF TRD115A-S*F ON-ON TRD115D-S*F ON-OFF-ON TRD115E-S*F ON-<ON> TRD115F-S*F <ON>-OFF-<ON> TRD115G-S*F ON-OFF-<ON> TRD115H-S*F 2-pole ON-OFF TRD215K-S*F ON-ON TRD215N-S*F ON-OFF-ON TRD215P-S*F ON-<ON> TRD215R-S*F <ON>-OFF-<ON> TRD215S-S*F ON-OFF-<ON> TRD215T-S*F 3) Solder terminal, with ON-OFF indication on actuator Number of poles Kind of operation Solder terminal Part No. 1-pole ON-OFF TRD115A-*1F 2-pole ON-OFF TRD215K-*1F 4) Screw terminal, with ON-OFF indication on actuator Number of poles Kind of operation Screw terminal Part No. 1-pole ON-OFF TRD115A-S*1F 2-pole ON-OFF TRD215K-S*1F Note: Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) ー 6 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 Note: Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) ■Standard type Notes: 1. Please specify the actuator color by replacing the asterisk “*” in the part number with appropriate letter. (B: black; W: white; R: red; Z: dark grey) 2. 300 V vinyl wire (VSF, thick: 2 mm2, length: 200 mm) is used. Please inquire about type and different length of lead wire. 2) With ON-OFF indication on actuator 1) Solder terminal 2) Screw terminal ■Wire lead sealed type 1) Without indication on actuator Number of poles Kind of operation < >: Momentary position Wire lead type Part No. 1-pole ON-OFF TRC115A-*F ON-ON TRC115D-*F ON-OFF-ON TRC115E-*F ON-<ON> TRC115F-*F ON-OFF-<ON> TRC115H-*F 2-pole ON-OFF TRC215K-*F ON-ON TRC215N-*F ON-OFF-ON TRC215P-*F ON-<ON> TRC215R-*F ON-OFF-<ON> TRC215T-*F Number of poles Kind of operation Wire lead type Part No. 1-pole ON-OFF TRC115A-*1F 2-pole ON-OFF TRC215K-*1F PUSH-BUTTON PRODUCT TYPES Number of poles Kind of operation Solder terminal Part No. 1-pole Momentary TB110F-F Alternate TB115D-F 2-pole Momentary TB210R-F Alternate TB215N-F Number of poles Kind of operation Screw terminal Part No. 1-pole Momentary TB110F-SF Alternate TB115D-SF 2-pole Momentary TB210R-SF Alternate TB215N-SF Notes: 1. Please use switch body with a color cap (sold separately). 2. Standard installation accessories are included with the product. With color cap installedSwitch body Color cap (sold separately) ー 7 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 ■Color cap for push-button (Option) Notes: 1. Please use switch body with a color cap (sold separately). 2. Standard installation accessories are included with the product. 2) Screw terminal ■Panel-sealed type 1) Solder terminal Note: Please specify the color cap color by replacing the asterisk “*” in the part number with appropriate letter (B: black; W: white; R: red; Z: dark grey; H: light grey; Y: yellow; G: green; L: blue). Number of poles Kind of operation Solder terminal Part No. 1-pole Momentary TBP110F-F Alternate TBP115D-F 2-pole Momentary TBP210R-F Alternate TBP215N-F Number of poles Kind of operation Screw terminal Part No. 1-pole Momentary TBP110F-SF Alternate TBP115D-SF 2-pole Momentary TBP210R-SF Alternate TBP215N-SF Product name Color cap (sold separately) Dimensions (Unit: mm) Part No. WDB1821* 11.2 13.2 dia. With color cap installedSwitch body Color cap (sold separately) Installation accessories (Repair parts) Product name Standard installation accessories Optional installation accessories Front hex nut (Nickel plated) Back hex nut (Uni-chrome plated) Keying washer Lock washer Front Knurl nut (Nickel plated) Dimensions (Unit: mm) (16.17) 2.3 M12 x 1 (16.17) 2.3 M12 x 1 2.8 18.2 dia. 12.3 dia. 2.4 9.7 15.6 dia. 12.3 dia. 0.5 1 15 dia. 2.4 M12 x 1 Part No. AJ3081 AJ3082 AJ3083 AJ3084 AJ3080 Note: A selling unit of each accessory is 10 pieces. ー 8 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 SPECIFICATIONS ■Contact rating 1) Toggle type and Rocker type ■Characteristics 2) Push-button type (momentary) Kind of load AC rating DC rating Resistive load 15A 250V 0.5A 250V, 0.9A 125V, 15A 30V Inductive load 15A 250V (Power factor: 0.6) 0.3A 250V (Time constant: 8 ms), 0.5A 125V (Time constant: 8 ms) 15A 30V (Time constant: 8 ms) Kind of load AC rating DC rating Resistive load 10A 250V 0.4A 250V, 0.8A 125V, 8A 30V 3) Push-button type (alternate) Kind of load AC rating DC rating Resistive load 15A 250V 0.5A 250V, 0.9A 125V, 15A 30V Item Specifications Shape of actuator Toggle type Rocker type Push-button type Mechanical expected life 1-pole and 2-pole: Min. 105 3-pole and 4-pole: Min. 8.5×104 Min. 5×104 (20 cpm) ON-OFF, ON-ON, ON-OFF-ON, Min. 3×104 (20 cpm) ON-(ON), (ON)-OFF-(ON), ON-OFF-(ON) Min. 3×104 (20 cpm) Electrical expected life (10 cpm) Standard and panel-sealed types: Min. 3×10 Terminal-sealed and wire leads types: Min. 1.5×104 Standard type: Min. 3×104 Panel-sealed, terminal-sealed and wire leads types: Min. 104 Min. 104 Dielectric strength 1500 Vrms (at detection current: 10mA) Insulation resistance Min. 100 MΩ (at 500 V DC measured by insulation resistive meter) Contact resistance Initial, Max. 10 mΩ (By voltage drop at 1 A, 2 to 4 V DC) Wire leads type only: Initial, Max. 30 mΩ (By voltage drop at 1 A, 2 to 4 V DC) Actuator strength 112.7N for 1 min. (For operating direction) Vibration resistance 10 to 55 Hz at double amplitude of 1.5 mm (contact opening: Max. 10 ms) Terminal strength (static load) 24.5N for 1 min. Ambient temperature –25°C to +70°C (Not freezing below 0°C) Contact material AgZnO alloy DATA (Electrical life, For toggle standard type) Tested condition: 250 V AC, Power factor: 0.6 and 10 cpm Current (A) 2-pole and 1pole types 4-pole and 3-pole types 6 10 14 18 22 26 30 Number of operations (×104) ー 9 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 TOGGLE TYPE DIMENSIONS The CAD data of the products with a CAD Data mark can be downloaded from https://industrial.panasonic.com/ac/e/ CAD Data External dimensions ■Standard type 1) Solder terminal (Unit: mm) General tolerance: ±0.5 5 2 6 3 4 1 23.7 M12×1 Keyway Keyway Hole for wire leads: 2 dia. Length: 4 6.1 dia. 30°±4° 12°±0.4° 17.5°±0.4° 15.8 Hole for wire leads: 2 dia. Length: 4 19.5 M12×1 17.5° ±0.4° 12°±0.4° 6.1 dia. 30°±8° 1-pole 2-pole 9 36 1 4 7 8 25 9 6 M12×1 Hole for wire leads: 2 dia. Length: 4 30°±4° 17.5°±0.4° 12°±0.4° 6.1 dia. Hole for wire leads: 2 dia. Length: 4 30°±4 17.5°±0.4° 12°±0.4° M12×1 6.1 dia. 36.5 3-pole 4-pole Keyway Keyway CAD Data External dimensions2) Screw terminal (M3.5) 15.8 19.5 9.3 6.1 dia. 30.3 9.3 17.5°±0.4° 12°±0.4° 6.1 dia. 12°±0.4° 17.5°±0.4° 330.4 5 2 4 1 1-pole 2-pole Keyway Keyway 30°±4° 30°±8 M12×1M12×1 9.3 30.3 36.5 9.3 30.3 8 5 9 6 7 4 6.1 dia. 17.5°±0.4° 12°±0.4° 330.4 17.5°±0.4° 12°±0.4° 330.4 6.1 dia. 3-pole 4-pole Keyway Keyway 30°±4° 30°±4° M12×1 M12×1 Note: ON-OFF type does not have terminal No. 2, 5, 8 and 11. Note: ON-OFF type does not have terminal No. 2, 5, 8 and 11. CAD Data External dimensions3) .250 Quick-connect terminal 6.1 dia. 15.8 9.3 19.5 9.3 30.3 17.5°±0.4° 12°±0.4° 17.5°±0.4° 12°±0.4° 6.1 dia. 4 1 6-.250 Quick- connect terminal 3-.250 Quick- connect terminal 1-pole 2-pole Keyway Keyway 30°±4° 30°±8° M12×1M12×1 9.3 30.3 9.3 36.5 30.3 6.1 dia. 17.5°±0.4° 12°±0.4° 6.1 dia. 12°±0.4° 17.5°±0.4° 9 6 3 5 2 69 3 8 5 7 4 110 9-.250 Quick- connect terminal 33 12-.250 Quick- connect terminal 3-pole 4-pole Keyway Keyway 30°±8° 30°±8° M12×1 M12×1 Notes: 1. ON-OFF type does not have terminal No. 2, 5, 8 and 11. 2. There is no through-hole on .250 Quick-connect terminals. ー 10 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 CAD Data External dimensions■Panel-sealed type 1) Solder terminal 17.5 7.5 15.8 23.7 19.5 5.5 dia. 18 dia. M12×1 26.96 107.5 17.5 D cut 3 2 1 30°±4° M12×118 dia. D cut 30°±8° 5.5 dia. 1-pole 2-pole 5.5 dia. 18 dia. 30°±4° M12×118 dia. 30°±8° 9.3 15.8 7.5 17.5 9.3 19.5 30.2 7.5 17.5 D cut M12×1 D cut 5.5 dia. 5 2 1-pole 2-pole Note: ON-OFF type does not have terminal No. 2 and 5. CAD Data External dimensions■Wire leads type Notes: 1. ON-OFF type does not have wire lead No. 2 and 5. 2. 300 V vinyl wire (VSF, thick: 2 mm2, length: 200 mm) is used. 2) Screw terminal (M3.5) CAD Data External dimensions■Terminal-sealed type 1) Solder terminal 26.9 10.37.5 17.5 5.5 dia. 30°±4° M12×118 dia. 30°±8° 5.5 dia. 23.7 10.37.5 17.5 D cut D cut M12×118 dia. 1-pole 2-pole 6 3 5 2 4 1 29 33 19.515.8 7.5 10.3 10.3 17.5 7.5 10.3 32.2 10.3 17.5 5.5 dia. M12×118 dia. 30°±8° 5.5 dia. M12×118 dia. D cut D cut 1-pole 2-pole 30°±4° 2 5 29 33 15.8 19.5 Note: ON-OFF type does not have terminal No. 2 and 5. 2) Screw terminal (M3.5) 30°±8° 5.5 dia. 18 dia. 30.6 23 1 D cut 30°±4° 10±4 15.8 200±20 3 2 7.5 17.5 10.3 33.2 D cut 21.1 10±4 200±20 18 dia. 5.5 dia. 10.37.5 36.4 17.5 1-pole 2-pole Color of wire leads No. Color

1 Brown

2 Red

3 Orange

4 Yellow

5 Green

6 Blue

M12×1 M12×1 ー 11 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 ROCKER TYPE DIMENSIONS CAD Data ■Standard type 1) Solder terminal (Unit: mm) General tolerance: ±0.5 13° 2515.8 19.5 13° 5.7 33.8 10.2 5.7 10.2 1-pole 2-pole 2-M3×0.5 2-M3×0.5 123 15.8 9.3 3 1 10.2 37.1 5.7 13° 13° 19.5 9.3 5.7 10.2 1-pole 2-pole 40.3 2-M3×0.52-M3×0.5 CAD Data External dimensions 1) Solder terminal 6 4 2 1 3 1 13° 13° 41 41 1-pole 7.8 2.5 27.7 2-pole 7.8 2.5 30.9 17 24 22 29 13 2 10.3 10.3 13° 2.5 27.7 7.8 2.5 13° 7.8 1-pole 2-pole 41 41 30.9 17 24 22 29 Notes: 1. ON-OFF type does not have terminal No. 2 and 5. 2. Dimensions of actuator: 13.4 × 27 Notes: 1. ON-OFF type does not have terminal No. 2 and 5. 2. Dimensions of actuator: 1-pole: 12.6 × 29, 2-pole: 17.4 × 29 CAD Data External dimensions 1) Solder terminal 2417 13°13° 27.7 2.5 7.8 41 41 29 22 2.5 7.8 23 1 1-pole 2-pole 30.9 17 24 10.3 22 29 10.3 13° 27.7 7.8 2.5 13° 7.8 2.5 3 2 1 1-pole 2-pole 30.9 Notes: 1. ON-OFF type does not have terminal No. 2 and 5. 2. Dimensions of actuator: 1-pole: 12.6 × 29, 2-pole: 17.4 × 29 External dimensions 2) Screw terminal (M3.5) ■Panel-sealed type ■Terminal-sealed type 2) Screw terminal (M3.5) 2) Screw terminal (M3.5) ー 12 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 CAD Data ■Wire leads type External dimensions

  • Solder terminal, Momentary Notes: 1. ON-OFF type does not have terminal No. 2 and 5. 2. Dimensions of actuator: 1-pole: 12.6 × 29, 2-pole: 17.4 × 29 3. 300 V vinyl wire (VSF, thick: 2 mm2, length: 200 mm) is used. External dimensions ■Standard type 13° 200±20 2 1 17 24 10±4 13° 42.2 2.5 7.8 41 41 10±4 2922 200±20 2.5 7.8 1-pole 2-pole Color of wire leads No. Color

45.4 PUSH-BUTTON TYPE DIMENSIONS (Unit: mm) General tolerance: ±0.5

  • Solder terminal, Alternate • Screw terminal (M3.5) Dimensions other than listed below are same as those of solder terminal type. 29 2 15.8 17.3 23.7 15.9 Keyway 4.7 M12×1 13.2 dia. 26.9 Keyway 144.7 9 15.9 13.2 dia. M12×1 1-pole 2-pole 19.5 M12×1 15.8 32.3 Keyway 5.9 17.19 13.2 dia. M12×1 5 2 32.4 Keyway 145.9 9 17.1 13.2 dia. 1-pole 2-pole 19.5 123 15.8 9.3 3 1 19.5 9.3 1-pole 2-pole External dimensions
  • Solder terminal, Momentary ■Panel-sealed type
  • Solder terminal, Alternate • Screw terminal (M3.5) Dimensions other than listed below are same as those of solder terminal type. 29 2 15.8 17.7 23.7 15.9 D cut 4.3 7.5 13.2 dia. 26.9 M12×1 14.4 15.9 D cut 4.3 7.5 13.2 dia. M12×1 1-pole 2-pole 19.5 15.8 32.3 5 2 32.4 14.4 15.9 D cut 4.3 7.5 13.2 dia. M12×1 14.4 15.9 D cut 4.3 7.5 13.2 dia. M12×1 1-pole 2-pole 19.5 123 15.8 9.3 3 1 19.5 9.3 1-pole 2-pole ー 13 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 ■Toggle type MOUNTING DIMENSIONS Type Standard type Panel cutout (Unit: mm) Panel thickness Max. 4.6 mm Max. 5.6 mm (without keying washer) Max. 5.6 mm (without keying washer) 12.5 dia. 3 dia. 9.2±0.1 ±0.2 12.5 dia. 12.3 dia. 11.5 1.5 Type Panel-sealed, Terminal-sealed and Wire leads types Panel cutout (Unit: mm) Panel thickness Max. 4 mm Max. 4 mm (without keying washer) 12.5 dia. 11.2 12.5 dia. Front hex nut Keying washer Lock washer Back hex nut Note: For panel installations of standard type, be use to use the back hex nut. ■Rocker type Type Standard type Panel-sealed, Terminal-sealed and Wire leads types Panel cutout (Unit: mm) Panel thickness Max. 4.5 mm 1.2 to 3.2 mm 2-3.5±0.1dia. 38±0.3 28+0.3 14.5+0.3 0 1 pole 2-pole 34.2±0.134.2±0.1 17.2±0.1 22.2±0.1 R0.5Max.R0.5Max. ■Push-button type Type Standard type Panel-sealed type Panel cutout (Unit: mm) Momentary, 1-pole: Momentary, 1-pole: Max. 10 mm Momentary, 2-pole: Max. 7.5 mm Alternate: Max. 7.5 mm (without keying washer) Momentary, 1-pole: Max. 11 mm Momentary, 2-pole: Max. 7.5 mm Alternate: Max. 7.5 mm (without keying washer) Max. 4 mm Max. 4 mm (without keying washer) Max. 10 mm Panel thickness Momentary, 2-pole: Max. 6.5 mm Alternate: Max. 6.5 mm 12.5 dia. 3 dia. 9.2±0.1 12.5 dia. 12.3 dia. 11.5 1.5 12.5 dia. 11.2 12.5 dia. Note: For panel installations of standard type, be use to use the back hex nut. ー 14 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 ■Toggle type and Rocker type TERMINAL CIRCUIT DIAGRAM Number of pole 1-pole 2-pole 3-pole 4-pole Toggle type Available Available Available *3 Available *3 Rocker type Available Available — — Terminal arrangement (As seen from terminal side) Actuator position and contact terminal number Actuator shape Toggle type Rocker type ON-OFF — — — — ON-ON ON-<ON> ON-OFF-ON <ON>-OFF-<ON> ON-OFF-<ON> — — — — Remarks ON-OFF type does not have a terminal No. 2. ON-OFF type does not have terminal No. 2 and 5. ON-OFF type does not have terminal No. 2, 5 and 8. ON-OFF type does not have terminal No. 2, 5, 8 and 11. Keyway Keyway Keyway Keyway Keyway KeywayKeyway Right Part No. Left Left Center Keyway Keyway Keyway Keyway Right Part No. Right Part No. Left Notes: *1. For ON-<ON>, ON-OFF-<ON> type of toggle, if the lever turns to the keyway side, it takes momentary position. *2. For the rocker type, if the actuator turns to the left side in view of the side where a part number is marked, it takes momentary position. *3. Only standard type ■Push-button type 1-pole 2-pole Terminal arrangement (As seen from terminal side) Push-button position and contact terminal number 2-3 2-3, 5-6 1-2 1-2, 4-5 Keyway Keyway Operated ー 15 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 CAUTIONS FOR USE ■Dustproof, waterproof, anticorrosive gas, and oil-proof designs The panel-sealed type/terminal-sealed type/wire lead type switch has a protection level of IP67 or IP64 on the outer side of the mounting panel and a level of IP40, IP60, or IP67 on the inner side of the panel. For actual application, note the following points: 1) Avoid immersion in water or oil during installation. 2) Avoid immersion in water or oil during operation. 3) Oils or gases impose varying degrees of impact on the switch’s sealing performance depending on type or quantity. 4) While the switch has a immersion and dust-protected design, its sealing performance or operabillity may be adversely affected in an environment where in the switch's movable parts can be contaminated with dust, oil, or other foreign objects. For the toggle type, use of a rubber cap is recommended. 5) The standard toggle switch, when used with a rubber cap, provides a protection level of IP54. It should be used in an environment where it will not be subject to frequent water splashes. 6) As the sealing performance of the rocker type switch is affected by the panel processing accuracy or mounted panel thickness, check the switch under actual loading conditions. (While water or dust will not enter the switch’s internal structure, it may enter the panel.) 7) Do not operate the rocker type switch when water accumulates in the actuator. ■Snap switch water resistance performance Panel front Panel interior Toggle type Rocker type Push- button type Toggle type Rocker type Push- button type Standard type + Rubber cap IP54 – – IP40 – – Panel-sealed type IP67 IP64 IP67 IP40 IP40 IP40 Terminal-sealed type IP67 IP64 – IP60 IP60 – Wire leads type IP67 IP64 – IP67 IP67 – ■Installation 1) For the toggle and push-button type a. When installing the standard type switch, be sure to use a hex nut. b. For the panel-sealed, terminal-sealed and wire lead types, use a lock washer on the front side of the panel, and an O-ring on the back side of it. c. Do not install the switch by rotating it. 2) For the rocker type a. In case the panel-sealed, terminal-sealed or wire leads types are used in the condition where the water splash on, please in the case of vertical installation, please install the switches tilt more than 25° or in the case of horizontal installation, please install the switches tilt more than 50°. (90° recommended) (Vertical installation) (Horizontal installation) Min. 50° Min. 25° Mounting panel b. In case water inside the switch case may freeze, please install the switch vertically to avoid the water remain inside the switch. 3) Rubber cap installation a. The washer should be used on the back side of the panel. 3.0 to 3.5 mm Washer Mounting hole Hexagonal nut b. Enough screw pitch should be obtained being adjusted within 3 to 3.5mm. c. After first installing the rubber cap, please tighten to 1.96 Nm or less with a hexagonal nut. d. The mounting hole in the panel should preferably be provided with an anti-rotation projection. e. If the rubber cap is installed over the hex nut, the waterproof performance will be impaired although the dustproof performance will not be affected. ■Soldering Perform soldering in less than 3 seconds with maximum 350°C iron. Care should be taken not to apply force to the terminals during soldering. We recommend a soldering iron with temperature adjustment in order to prevent poor quality soldering. Please consult us if you intend to use a soldering iron of 60 W or higher. ■Load type and ratings 1) When the switch is loaded with a lamp, motor or capacitive load, a surge current higher than the stationary current passes through the switch contacts. Measure the surge with the actual load and, if needed, take necessory action so that the surge will not exceed the switch’s rated current. 2) When the switch is loaded with an inductive load (relay, solenoid, buzzer, etc.), a contact failure may result from arc discharge caused by a counterelectromotive force. It is advisable that you use an adequate anti-spark circuit across the switch contacts. ■Others 1) Do not apply an excessive static load exceeding 112.7N perpendicular to the direction of operation. 2) Operate the switch actuator by hand. 3) Take care not to drop the product as it may impair performance. 4) These switches are only for Industrial use. Do not use any other applications. (ex. home use) ー 16 ー

Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB5E 201906 REFERENCE ■Dust-protected type This type of construction prevents dust that is large enough to have an effect on operation from getting inside the unit. This construction is stipulated by protective classes against solid matter in the IEC standards (IEC60529). The talcum powder used shall be able to pass through a squaremeshed sieve the nominal wire diameter of 75 μm. The amount of talcum powder to be used is 2 kg per cubic metre of the test chamber volume. The duration of the test is 8 hours. No damage observed after the test.

  • Level of protection indicated by the 1st Characteristics number ■Immersion-protected type This type of construction prevents any harmful effects even after the device is left underwater at a depth of 1 m for 30 minutes. This construction is stipulated by protective classes against water in the IEC standards (IEC60529). ■IEC’s IP Codes The IEC (International Electrotechnical Commission) has defined the IP characteristic code that represents the levels of protection described in IEC standard (IEC60529). The two numbers that follow the IP code (the characteristics numbers) indicate the suitability of this protection for all environmental conditions. 1st characteristics number 2nd characteristics number IP 1st Characteristics number Protection level (IEC60529/Solid matter)

0 No protection

1 Protected against solid matter larger than 50mm

2 Protected against solid matter larger than 12mm

3 Protected against solid matter larger than 2.5mm 4 Protected against solid matter larger than 1.0mm Dust-protected type Prevents dust that is large enough to have an effect on operation from getting inside the unit

6 Dust-resistant type

Prevents dust from getting inside the unit

  • Level of protection indicated by the 2nd Characteristics number JIS C0920 2nd Characteristics number Protection level (IEC60529/Liquid matter)

type I 1 Protected against water droplets that fall perpendicular to the unit Droplet-protected type II 2 Protected against water droplets that fall from within 15° of perpendicular to the unit Rain-protected type 3 Protected against water droplets that fall from within 60° of perpendicular to the unit Splash-protected type 4 Protected against water that splashes on the unit from any direction Spray-protected type 5 Free from adverse effects even if sprayed directly with water from any direction Water-resistant type 6 Protected against water sprayed directly on the unit from any direction Immersion- protected type 7 Water does not get inside of the unit when submerged in water according to the specified conditions Underwater type 8 Unit can be used underwater Note: Details of test conditions are the same as NECA C 0920. Please refer to them. ー 17 ー

Technical Terminology & Cautions for Use AECTB38E 201811-T (Operation Switches) TECHNICAL TERMINOLOGY Technical Terminology & Cautions for Use ■ Rated values Values indicating the characteristics and performance guarantee standards of the switches. The rated current and rated voltage, for instance, assume specific conditions. ■ Electrical life The service life when the rated load is connected to the contact and switching operations are performed. ■ Mechanical life The service life when operated at a preset operating frequency without passing electricity through the contacts. ■ Dielectric strength Threshold limit value that a high voltage can be applied to a predetermined measuring location for one minute without causing damage to the insulation. ■ Insulation resistance This is the resistance value at the same place the dielectric strength is measured. ■ Contact resistance This indicates the electrical resistance at the contact part. Generally, this resistance includes the conductor resistance of the spring and terminal portions. ■ Vibration resistance Vibration range where a closed contact does not open for longer than a specified time due to vibrations during use of the snap- action switches. ■ Shock resistance Max. shock value where a closed contact does not open for longer than a specified time due to shocks during use of the switches. ■ Allowable switching frequency This is the maximum switching frequency required to reach the end of mechanical life (or electrical life). ■ Temperature rise value This is the maximum temperature rise value that heats the terminal portion when the rated current is flowing through the contacts. ■ Actuator strength When applying a static load for a certain period on the actuator in the operation direction, this is the maximum load it can withstand before the switch loses functionality. ■ Terminal strength When applying a static load for a certain period (in all directions if not stipulated) on a terminal, this is the maximum load it can withstand before the terminal loses functionality (except when the terminal is deformed). ー 18 ー

Technical Terminology & Cautions for Use AECTB38E 201811-T TYPES OF LOAD ■ Resistance load Resistance load is a power factor of 1 (cosφ = 1) where the load is only for the resistance portion. The displayed switch rating indicates the current capacity when using AC current. ■ DC load Differing from AC, since the direction of current is fixed for DC, the continuous arc time lengthens when the same voltage is applied. ■ Incandescent lamp load Since an inrush current of 10 to 15 times the rated current flows for an instant when the switch is turned on for the lamp, adhesion of the contacts may occur. Therefore, please take into consideration this transient current when selecting a switch. ■ Induction load Since arc generation due to reverse voltage can cause contact failure to occur when there is an induction load (in relays, solenoids and buzzers, etc.), we recommend you insert a suitable spark quenching circuit (see figure below). ■ Motor load Contacts may adhere due to the starting current at the start of motor operation which is three to eight times the steady-state current. Although it differs depending on the motor, since a current flows that is several times that of the nominal current, please select a switch taking into consideration the values in the table below. To make the motor rotate in reverse, use an ON- OFF-ON switch and take measures to prevent a multiplier current (starting current + reverse current) from flowing. A current that is approximately two times that of the starting current will flow when reverse rotation is caused during operation. Also, when using for a load that will cause transient phenomena such as when operating the motor in reverse rotation or switching the poles, an arc short (circuit short) may occur due to the time lag between poles when switching. Please be careful. ■ Capacitor load In the case of mercury lamps, florescent lamps and the capacitor loads of capacitor circuits, since an extremely large inrush current flows when the switch is turned on, please measure that transient value with the actual load and then either use the product keeping within the range of the rated current or after verifying the actual load. Circuit example Notes Switch contact (1) r = more than 10 Ω (2) In an AC circuit, impedance of R is to be slightly smaller than impedance of r and c. Switch contact Can be used for both AC and DC circuits. r = R C: 0.1 μF Switch contact For DC circuits only. Switch contact Can be used for both AC and DC circuits. rc R r c R Rdiode ZNR Varistor Induction load Motor type Type Starting current Three-phase induction motor Squirrel-cage Approx. 5 to 8 times current listed on nameplate Single-phase induction motor Split-phase-start Approx. 6 times current listed on nameplate Capacitor-start Approx. 4 to 5 times current listed on nameplate Repulsion-start Approx. 3 times current listed on nameplate Example of 1-pole motor reverse rotation circuit Good wiring Bad wiring Example of single-phase induction motor (capacitor) strong-weak switching circuit Good wiring Bad wiring Example of three-phase motor reverse rotation circuit Good wiring Bad wiring MM Power supply Power supply M M Power supply Weak Strong Strong Strong Strong Weak Weak Power supply Weak M M Power supply Power supply ー 19 ー

Technical Terminology & Cautions for Use AECTB38E 201811-T CAUTIONS FOR USE ■ Environment of use 1) Please consult us when using under the following conditions:

  • Environments where hydrogen sulfide or other corrosive gases are present.
  • Environments where gasoline, thinner or other flammable, explosive gases are present.
  • Dusty environments (for non-seal type snap action switches).
  • Use in environments not in the prescribed temperature or humidity range.
  • Places with low air pressure. 2) Unless specified the product will not be constructed to withstand water, oil or explosions. Please inquire if you intend to use the product in special applications. ■ Usage, storage, and transport conditions 1) During usage, storage, or transportation, avoid locations subject to direct sunlight and maintain normal temperature, humidity, and pressure conditions. 2) The allowable specifications for environments suitable for usage, storage, and transportation are given below. (1) Temperature: The allowable temperature range differs for each switch, so refer to the switch’s individual specifications. (2) Humidity: 5 to 85% R.H. (3) Pressure: 86 to 106 kPa The humidity range varies with the temperature. Use within the range indicated in the graph below. (The allowable temperature depends on the switch.)
  • Condensation will occur inside the switch if there is a sudden change in ambient temperature when used in an atmosphere of high temperature and high humidity. This is particularly likely to happen when being transported by ship, so please be careful of the atmosphere when shipping. Condensation is the phenomenon whereby steam condenses to cause water droplets that adhere to the switch when an atmosphere of high temperature and humidity rapidly changes from a high to low temperature or when the switch is quickly moved from a low humidity location to one of high temperature and humidity. Please be careful because condensation can cause adverse conditions such as deterioration of insulation, coil cutoff, and rust.
  • Condensation or other moisture may freeze on the switch when the temperatures is lower than 0°C 32°F. This causes problems such as sticking of movable parts or operational time lags.
  • The plastic becomes brittle if the switch is exposed to a low temperature, low humidity environment for long periods of time.
  • Storage for extended periods of time (including transportation periods) at high temperatures or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and/or it may interfere with the functions. Check out the atmosphere in which the units are to be stored and transported.
  • In terms of the packing format used, make every effort to keep the effects of moisture, organic gases and sulfide gases to the absolute minimum. ■ Wiring 1) When using a PC board terminal switch as soldering terminals, use thin lead wires and be sure to wind them on the terminals before soldering. 2) Cautions when soldering Perform soldering quickly in accordance with the specified conditions. Be careful not to let flux flow into the product. When no instruction is specified, use a soldering iron with a tip temperature of 350°C or lower and complete soldering within five seconds. Do not pull on the lead wires immediately after soldering. Wait some time before verifying. ■ Others 1) Failure modes of switches include short-circuiting, open- circuiting and temperature rises. If this switch is to be used in equipment where safety is a prime consideration, examine the possible effects of these failures on the equipment concerned, and ensure safety by providing protection circuits or protection devices. In terms of the systems involved, make provision for redundancy in the design and take steps to achieve safety design. 2) The ambient operating temperature (and humidity) range quoted is the range in which the switch can be operated on a continuous basis: it does not mean that using the switch within the rating guarantees the durability performance and environment withstanding performance of the switch. For details on the performance guarantee, check the specifications of each product concerned. 3) Even if 2-pole, 3-pole or 4-pole switches are used as single- pole switches in order to increase contact reliability, please keep the maximum current no higher than the rated value. 4) If there is the possibility of a short between poles, please use an in-phase circuit as shown below or provide a spare pole. 5) Be careful not to drop the product as this may cause loss of functionality. 6) Do not apply an unreasonable vertical force against the direction of operation of the product. 7) Use your hand to operate the actuator. (Operation using a tool such as a screwdriver or hammer can cause breakdown.) Tolerance range (Avoid condensation when used at temperatures higher than 0°C 32°F) (Avoid freezing when used at temperatures lower than 0°C 32°F) –40 –40 +32 +85 +185 Temperature, °C °F Humidity, %R.H. Bad example Good example (1) Good example (2) Load 1 Load 1 Heteropolar circuit In-phase circuit Load 2 Load 1 Spare pole Load 2 Load 2 ー 20 ー