  • Care Motion
  • Comfort Motion
  • Industrial Motion TA38M series TiMOTION’s TA38M series linear actuator is specially designed for medical applications where a compact linear actuator is needed. The TA38M features a very slim design with a small installation size of only stroke plus 115mm (note 1), providing manufacturers great freedom during the design process. The palm-sized motor with up to 2000N force is excellent for all kinds of space- limited products. Note 1: If stroke is from 20 to 45mm, the retracted length needs to ≥ 160mm. General Features Max. load 2,000N (push); 1,500N (pull) Max. speed at max. load 6.2mm/s Max. speed at no load 20mm/s Retracted length ≥ 160mm (depending on chosen options) IP Rating IP66 Stroke 20~300mm Options Hall sensors Voltage 12/24V DC; 12/24V DC (PTC) Color Black, grey Operational temperature range +5°C~+45°C

(mm) Drawing ø17 ø8.2 5.2 12.212.2 18.5 Retracted Length 5.2 ø8.2 1 7. 2 61 .5 Note 1 Please refer to the approved drawing for the final authentic value. 2 The current & speed in table are tested with 24V DC motor. With a 12V DC motor, the current is approximately twice the current measured in 24V DC; speed will be similar for both voltages. 3 This self-locking force level is reached only when a short circuit is applied on the terminals of the motor. All the TiMOTION control boxes have this feature built-in. 4 The current & speed in table are tested when the actuator is extending under push load. 5 The data in the performance charts shows theoretical value using specific TiMOTION control boxes. Please contact TiMOTION for more details. 6 Standard stroke: Min. ≥ 20mm, Max. please refer to below table. Load and Speed CODE Load (N) Self Locking Force (N) Typical Current (A) Typical Speed (mm/s) Push Pull No Load 32V DC With Load 24V DC No Load 32V DC With Load 24V DC Motor Speed (6000RPM, Duty Cycle 10%) B 1500 1500 1200 1.3 3.8 15.8 9.2 C 2000 1500 2000 1.3 3.8 11.4 6.2 E 500 500 500 1.3 2.0 20.0 14.2 CODE Load (N) Max Stroke (mm) B, E ≤ 1500 300 C 2000 300

Motor Speed (6000RPM, Duty Cycle 10%) Performance Data (24V DC Motor) TA38M series 0.0 0 1000 2000 3000 4000 5000 10.0 20.0 30.0 40.0 50.0 60.0 E B C Speed (mm/s) Speed vs. Load Load (N) E B C 1000 2000 3000 4000 5000 0.0 1.0 2.0 3.0 4.0 5.0 6.0 Current (A) Current vs. Load Load (N)

Version: 20220407-F Load and Speed Voltage See page 5 Cable Length (mm) Output Signals IP Rating Special Functions for Spindle Sub- Assembly Connector See page 7 Color Direction of Rear Attachment (Counterclockwise) See page 6 1 = 12V DC 2 = 24V DC 5 = 24V DC, PTC 6 = 12V DC, PTC 0 = Straight, 100 1 = Straight, 500 2 = Straight, 750 3 = Straight, 1000 4 = Straight, 1250 5 = Straight, 1500 6 = Straight, 2000 7 = Curly, 200 8 = Curly, 400 B~H = For direct cut system. See page 7 0 = Without 5 = Hall sensor * 2 1 = Without 2 = IP54 3 = IP66 0 = Without 2 = Standard push only 1 = Black 2 = Pantone 428C 1 = 90° 2 = 0° Stroke (mm) Retracted Length (mm) Functions for Limit Switches See page 6 1 = Two switches at full retracted / extended positions to cut current 3 = Two switches at full retracted / extended positions to send signal See page 2 See page 2 See page 5 Rear Attachment (mm) See page 5 Front Attachment (mm) See page 6 E = Aluminum casting, U clevis, width 5.2, depth 12.2, hole 6.2 G = Aluminum casting, U clevis, width 5.2, depth 12.2, hole 8.2 1 = DIN 6P , 90° plug 2 = Tinned leads 4 = Big 01P , plug C = Y cable (For direct cut system, water proof, anti pull) E = Molex 8P , plug F = DIN 6P , 180° plug P = Molex 8P , 90° plug, without anti-clip Q = Molex 6P , 90° plug, without anti-clip E = Aluminum casting, U clevis, width 5.2, depth 12.2, hole 6.2 G = Aluminum casting, U clevis, width 5.2, depth 12.2, hole 8.2 N = Aluminum casting, without slot, hole 6.2 P = Aluminum casting, without slot, hole 8.2

  1. Calculate A+B = Y 2. Stroke 25~45mm, the retracted length needs to ≥ 160mm 3. Stroke 46~200mm, the retracted length needs to ≥ Stroke + Y 4. Code#E Standard stroke: Min. ≥ 40mm, tthe retracted length needs to ≥ S + 125mm Retracted Length (mm) Stroke (mm) General PTC Option 20~200 - - 201~250 +13 +5 251~300 +18 +10 Front Attach. Rear Attach. General PTC Option E, G E, G E, G +115 +123 N, P +108 +116 250mm 100mm PTC E = Aluminum casting, U clevis, width 5.2, depth 12.2, hole 6.2 G = Aluminum casting, U clevis, width 5.2, depth 12.2, hole 8.2 Rear Attachment (mm) Voltage 5.2 17 17 12.2 ø6.2 5.2 17 17 12.2 ø8.2

Direction of Rear Attachment (Counterclockwise) 1 = 90° 2 = 0° Functions for Limit Switches Wire Definitions CODE Pin 1 (Green) 2 (Red) 3 (White) 4 (Black) 5 (Yellow) 6 (Blue) 1 extend (VDC+) N/A N/A N/A retract (VDC+) N/A 3 extend (VDC+) common upper limit switch N/A retract (VDC+) lower limit switch E = Aluminum casting, U clevis, width 5.2, depth 12.2, hole 6.2 G = Aluminum casting, U clevis, width 5.2, depth 12.2, hole 8.2 N = Aluminum casting, without slot, hole 6.2 P = Aluminum casting, without slot, hole 8.2 Front Attachment (mm) ø17 ø6.2 8.5 ø17 ø8.2 8.5 Hole Hole 90º 6.7 23.5 12.8 ø6.2 6.7 23.5 12.8 ø8.2

The user is responsible for determining the suitability of TiMOTION products for a specific application. TiMOTION products are subject to change without prior notice. E = Molex 8P , plug F = DIN 6P , 180° plug P = Molex 8P , 90° plug, without anti-clip Q = Molex 6P , 90° plug, without anti-clip Connector 1 = DIN 6P , 90° plug 2 = Tinned leads 4 = Big 01P , plug C = Y cable (For direct cut system, water proof, anti pull) L2 L1 L3 Cable Length for Direct Cut System (mm) CODE L1 L2 L3 B 100 100 100 C 100 1000 400 D 100 2700 500 E 1000 100 100 F 100 600 1000 G 1500 1000 1000 H 100 100 1200