TiMOTION’s TA21 electric linear actuator was designed for use in height adjustable medical and industrial workstations. Customers have a high degree of design flexibility with this actuator as it does not include a standard outer tube. This allows manufacturers to decide on the exact aesthetic and ingress specifications for their electric lifting column and overall application. General Features Max. load 10,000N (push); 6,000N (pull) Max. speed at max. load 6.3mm/s Max. speed at no load 24.7mm/s Retracted length ≥ 67mm Certificate UL962 Stroke 25~400mm Output signals Hall sensors, Reed sensor Voltage 24V DC; 24V DC (UL) Color Black, grey High design flexibility Product Segments

  • Care Motion
  • Ergo Motion
  • Industrial Motion TA21 series

1 Please refer to the approved drawing for the final authentic value. 2 This self-locking force level is reached only when a short circuit is applied on the terminals of the motor. All the TiMOTION control boxes have this feature built-in.

3 Operational temperature range: +5°C~+45°C

4 The current & speed in table are tested when the actuator is extending under push load. 5 The current & speed in table and diagram are tested with a stable 24V DC power supply. TA21 series Standard Dimensions (mm) Retracted length L1, Min ≥ 67mm (NO need to add stroke length) Drawing Load and Speed CODE Load (N) Self Locking Force (N) Typical Current (A) Typical Speed (mm/s) Push Pull No Load 24V DC With Load 24V DC No Load 24V DC With Load 24V DC Motor Speed (3800RPM, duty cycle 10%) A 10000 6000 10000 2.0 15.0 12.1 6.3 C 7000 6000 6000 2.0 9.0 12.3 8.3 D 4000 4000 3000 2.0 9.5 24.7 16.2 ø49.5 4*M5 ø63.5 82.7 55.4 ø32.8 22.8 172.5 Retracted Length 16.4 ø32.8 82.7172.5

63 L1Stroke

ø63.5

Motor Speed (3800RPM) Performance Data (24V DC Motor) TA21 series 10.0 0.0 20.0 30.0 40.0 50.0 60.0 0 3000 6000 9000 12000 15000 D A C Speed (mm/s) Speed vs. Load Load (N) 3.0 0.0 6.0 9.0 12.0 15.0 0 3000 6000 9000 1200 1500 D A C Current (A) Current vs. Load Load (N)

Version: 20231005-I Load and Speed Voltage Cable Length (mm) Signal Output Connector 2 = 24V DC 5 = 24V DC, UL 1 = Straight, 500 2 = Straight, 750 3 = Straight, 1000 4 = Straight, 1250 5 = Straight, 1500 6 = Straight, 2000 7 = Curly, 200 8 = Curly, 400 0 = Without 2 = Hall sensors*2 3 = Reed Sensor 1 = DIN 6P , 90° plug 2 = Tinned leads F = DIN 6P , 180° plug Stroke (mm) Retracted Length (mm) See page 2 See page 2 See page 2 Motor Cable Color Special Functions for Spindle Sub- Assembly 1 = Black 2 = Grey (Pantone 428C) 1 = Safety nut Terms of Use The user is responsible for determining the suitability of TiMOTION products for a specific application. TiMOTION products are subject to change without prior notice.