  • Care Motion TA10 series TiMOTION’s TA10 series linear actuator is primarily used in the medical market. This actuator series handles high loads and is designed with a manual crank attachment. If necessary, medical staff will be able to easily operate the manual crank to adjust the patient bed. In addition, this linear actuator is available with an optional IP54 or 66 rating. General Features Max. load 6,000N (push), 4,000N (pull) Max. speed at max. load 4.2mm/s Max. speed at no load 14.5mm/s Retracted length ≥ Stroke + 188mm IP rating IP66 Certificate IEC60601-1, ES60601-1 Stroke 25~300mm Options Hall sensor (s) Voltage 12V DC, 24V DC, 36V DC or 24V DC (PTC) Color Black or grey Operational temperature range +5°C~+45°C With manual crank function

(mm) Drawing Load and Speed CODE Load (N) Self Locking Force (N) Typical Current (A) Typical Speed (mm/s) Push Pull No Load 32V DC With Load 24V DC No Load 32V DC With Load 24V DC Motor Speed (2600RPM, Duty Cycle 10%) D 6000 4000 2500 ≤ 0.6 3.6 5.95 3.3 J 3500 3500 1500 ≤ 0.6 3.7 11.5 5.8 Motor Speed (3400RPM, Duty Cycle 10%) L 6000 4000 2500 ≤ 0.7 4.2 7.3 4.2 Q 3500 3500 1500 ≤ 0.7 4.8 14.5 7.7 CODE Load (N) Max Stroke (mm) J, Q = 3500 300 D, L = 6000 200 Note 1 Please refer to the approved drawing for the final authentic value. 2 This self-locking force level is reached only when a short circuit is applied on the terminals of the motor. All the TiMOTION control boxes have this feature built-in. 3 The current & speed in table are tested when the actuator is extending under push load. 4 The current & speed in table and diagram are tested with TiMOTION control boxes, and there will be around 10% tolerance depending on different models of the control box. (Under no load condition, the voltage is around 32V DC. At rated load, the voltage output will be around 24V DC) 5 The current & speed in table and diagram are tested with a stable 24V DC power supply. 6 Standard stroke: Min. ≥ 25mm, Max. please refer to below table. 35.8 26.5 84.5 153 Retracted Length 56.8 40 26.5 84.5 113

Motor Speed (2600RPM) Performance Data (24V DC Motor) TA10 series D J5.0 0.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 0 2000 4000 60001000 3000 5000 7000 Speed (mm/s) Speed vs. Load Load (N) DJ 1.0 0.0 2.0 3.0 4.0 6.0 5.0 0 2000 4000 60001000 3000 5000 7000 Current (A) Current vs. Load Load (N)

Motor Speed (3400RPM) Performance Data (24V DC Motor) TA10 series L Q 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 0 2000 4000 60001000 3000 5000 7000 Speed (mm/s) Speed vs. Load Load (N) L Q 0.0 0 2000 4000 60001000 3000 5000 7000 1.0 2.0 3.0 4.0 5.0 6.0 Current (A) Current vs. Load Load (N)

Cable Length (mm) Output Signal Brake IP Rating Connector See page 8 Color Direction of Rear Attachment (Counterclockwise) See page 7 1 = 12V DC 2 = 24V DC 3 = 36V DC 5 = 24V DC, PTC 0 = Straight, 100 1 = Straight, 500 2 = Straight, 750 3 = Straight, 1000 4 = Straight, 1250 5 = Straight, 1500 6 = Straight, 2000 7 = Curly, 200 8 = Curly, 400 0 = Without 1 = Hall sensor*1 2 = Hall sensor*2 0 = Without 1 = Without 2 = IP54 3 = IP66 1 = Black 2 = Pantone 428C 1 = 0° 2 = 90° Stroke (mm) Retracted Length (mm) Functions for Limit Switches See page 7 1 = Two switches at full retracted / extended positions to cut current 2 = Two switches at the retracted / extended positions to cut current with the third one in between to send signal 3 = Two switches at the retracted / extended positions to send signal 4 = Two switches at the retracted / extended positions and the third one in between to send signal See page 2 See page 6 See page 6 Rear Attachment (mm) See page 7 Front Attachment (mm) See page 7 1 = Aluminum CNC, without slot, hole 10.2, for hand crank 2 = Aluminum CNC, without slot, hole 12.2, for hand crank 1 = DIN 6P , 90° plug 2 = Tinned leads 3 = Small 01P , plug 4 = Big 01P , plug 1 = Casting, width 32, hole 10.2 2 = Casting, width 32, hole 12.2 Version: 20200603-F

  1. Calculate A = Y 2. Retracted length needs to ≥ Stroke+Y *Retracted length : S + 188 Retracted Length (mm) Stroke (mm) Load (N) General < 6000 = 6000 25~150 - - 151~200 - - 201~250 - +5 251~300 - +10 301~350 +5 +15 351~400 +10 +20 401~450 +15 +25 451~500 +20 +30 501~550 +25 +35 551~600 +30 +40 601~650 +35 x 651~700 +40 x 701~750 +45 x 751~800 +50 x 801~850 +55 x 851~900 +60 x 901~950 +65 x 951~1000 +70 x

1 = Aluminum CNC, without slot, hole 10.2, for hand crank 2 = Aluminum CNC, without slot, hole 12.2, for hand crank Rear Attachment (mm) 1 = Casting, width 32, hole 10.2 2 = Casting, width 32, hole 12.2 Front Attachment (mm) ø36 15.5 ø10.2 ø36 15.5 ø12.2 1 = 0° 2 = 90° Direction of Rear Attachment (Counterclockwise) Functions for Limit Switches Wire Definitions CODE Pin 1 (Green) 2 (Red) 3 (White) 4 (Black) 5 (Yellow) 6 (Blue) 1 extend (VDC+) N/A N/A N/A retract (VDC+) N/A 2 extend (VDC+) N/A middle switch pin B middle switch pin A retract (VDC+) N/A 3 extend (VDC+) common upper limit switch N/A retract (VDC+) lower limit switch 4 extend (VDC+) common upper limit switch medium limit switch retract (VDC+) lower limit switch ø32 12 ø10.2 ø32 12 ø12.2

The user is responsible for determining the suitability of TiMOTION products for a specific application. TiMOTION products are subject to change without prior notice. 1 = DIN 6P , 90° plug 2 = Tinned leads 4 = Big 01P , plug Connector