© Panasonic Corporation 2019 industrial.panasonic.com/ac/e/ AECTB24E 2019032019.03 PRODUCT TYPES
FEATURES
(250 V AC)/15 A (125 V AC) Switching
- Capable of high capacity switching (10 A 250 V AC and
15 A 125 V AC)
- Terminals constructed for easy implementation DATA (Life curve) 12 dia. These switches are only for Industrial use. Do not use any other applications. (ex. home use) Note: The product comes with standard installation accessories. However, keying washer is sold separately. Number of poles Kind of operation Solder terminal Left Right Part No. 1-pole ON OFF T110A-F ON ON T110D-F 2-pole ON OFF T210K-F ON ON T210N-F Tested condition: 250 V AC, Power factor: 0.6 and 10 cpm Current (A) Number of operations (×104) 1 3 5 7 9 11 13 15 Automation Controls Catalog
Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB24E 201903 SPECIFICATIONS TERMINAL CIRCUIT DIAGRAM ■ Contact rating Kind of load AC rating DC rating Resistive load 10A 250V AC 15A 125V AC 8A 30V DC 0.8A 125V DC 0.4A 250V DC Inductive load 10A 250V AC (Power factor: 0.6) 15A 125V AC (Power factor: 0.6) 5A 30V DC (Time constant: 7 msec.) 0.4A 125V DC (Time constant: 7 msec.) 0.2A 250V DC (Time constant: 7 msec.) Lamp load (incandescent) 300W 100V AC 500W 200V AC Inrush current: Max. 30 A Motor load 200W 125V AC 300W 250V AC — ■ Characteristics Item Specifications Mechanical expected life Min. 105 Electrical expected life Min. 3×104 (10 cpm) (at rated load) Overload life Min. 50 (5 cpm) (Rated load×1.5) Insulation resistance Min. 100 MΩ (at 500 V DC measured by insulation resistive meter) Dielectric strength 1500 Vrms (at detection current: 10mA) Vibration resistance 10 to 55 Hz at double amplitude of 1.5 mm (contact opening: Max. 1 ms) Contact resistance Initial, Max. 20 mΩ (by voltage drop at 1 A, 2 to 4 V DC) Actuator strength (static load) 112.7N for 1 min. Terminal strength (static load) 24.5N for 1 min. Ambient temperature –25°C to +70°C (no freezing and condensing) Contact material AgZnO alloy 1-pole 2-pole Terminal arrangement (As seen from terminal side) Actuator position and contact terminal number ON-OFF 1-3 1-3, 4-6 — — — — — ON-ON 2-3 2-3, 5-6 — — — 1-2 1-2, 4-5 Remark ON-OFF type does not have a terminal No. 2. ON-OFF type does not have terminal No. 2 and 5. Keyway Keyway Keyway Keyway Keyway Keyway
Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ © Panasonic Corporation 2019 AECTB24E 201903 DIMENSIONS The CAD data of the products with a CAD Data mark can be downloaded from https://industrial.panasonic.com/ac/e/ CAD Data (Unit: mm) General tolerance: ±0.5 External dimensions 27 17.5±0.412±0.4 19.5 6.1 dia. 17.5±0.412±0.4 6.1 dia. 15.8 23.7 Keyway Keyway M12×1 M12×1 2-pole1 pole 30°±4° 30°±8° Note: ON-OFF type does not have terminal No. 2 and 5. MOUNTING DIMENSIONS Applicable part No. All product types Panel cutout (Unit: mm) Panel thickness Max. 4.6 mm* 12.5 dia. 9.2±0.1 3 dia. +0.2 12.5 dia. 12.3 dia. 11.5 1.5 Notes: 1. For panel installations, use the back hex nut. 2. * Keying washer (separately sold) Part No.: AJ3083 ■ Accessories (Option) Product name Indication plate (aluminum) (Note 3) Rubber cap (Note 1, 2, 4) ON-OFF ON-ON EP rubber type Silicone rubber type Dimensions (Unit: mm) Part No. WD1901 WD1902 WD1911 WD1811* 12.3 dia. 30 1.3 1.5 0.8 0.8 17 12.3 dia. 30 1.3 1.5 0.8 0.8 17 10 dia. 24.5 21 dia. M12 8 dia. 24.5 18 dia. M12 8.6 Notes: 1. The asterisk “*” in the part number WD1811* for the silicon rubber type rubber cap is where the letter representing the color should be inserted. (B: black; R: red; Z: grey; Y: yellow; G: green.) 2. EP rubber cap is available in black only. 3. Letters on the display panel are aluminum colored and the area surrounding the letters is black. 4. Indication plate and rubber cap are compatible with the T-15 series switch, T-10 series switch, and T-03/T-06 series switches (when plate thickness is 2.7 mm or less).
- Using the different rubber caps We recommend silicon rubber and EP rubber caps for the following applications. 1) Silicon rubber type
- When it is necessary to differentiate by color.
- When using in applications that require resistance to heat and cold. Ambient temperature: –25°C to +85°C (EP rubber type is 0°C to +40°C.)
- When compactness is required. 2) EP rubber type When cost is the primary consideration.
Technical Terminology & Cautions for Use AECTB38E 201811-T (Operation Switches) TECHNICAL TERMINOLOGY Technical Terminology & Cautions for Use ■ Rated values Values indicating the characteristics and performance guarantee standards of the switches. The rated current and rated voltage, for instance, assume specific conditions. ■ Electrical life The service life when the rated load is connected to the contact and switching operations are performed. ■ Mechanical life The service life when operated at a preset operating frequency without passing electricity through the contacts. ■ Dielectric strength Threshold limit value that a high voltage can be applied to a predetermined measuring location for one minute without causing damage to the insulation. ■ Insulation resistance This is the resistance value at the same place the dielectric strength is measured. ■ Contact resistance This indicates the electrical resistance at the contact part. Generally, this resistance includes the conductor resistance of the spring and terminal portions. ■ Vibration resistance Vibration range where a closed contact does not open for longer than a specified time due to vibrations during use of the snap- action switches. ■ Shock resistance Max. shock value where a closed contact does not open for longer than a specified time due to shocks during use of the switches. ■ Allowable switching frequency This is the maximum switching frequency required to reach the end of mechanical life (or electrical life). ■ Temperature rise value This is the maximum temperature rise value that heats the terminal portion when the rated current is flowing through the contacts. ■ Actuator strength When applying a static load for a certain period on the actuator in the operation direction, this is the maximum load it can withstand before the switch loses functionality. ■ Terminal strength When applying a static load for a certain period (in all directions if not stipulated) on a terminal, this is the maximum load it can withstand before the terminal loses functionality (except when the terminal is deformed). ー 4 ー
Technical Terminology & Cautions for Use AECTB38E 201811-T TYPES OF LOAD ■ Resistance load Resistance load is a power factor of 1 (cosφ = 1) where the load is only for the resistance portion. The displayed switch rating indicates the current capacity when using AC current. ■ DC load Differing from AC, since the direction of current is fixed for DC, the continuous arc time lengthens when the same voltage is applied. ■ Incandescent lamp load Since an inrush current of 10 to 15 times the rated current flows for an instant when the switch is turned on for the lamp, adhesion of the contacts may occur. Therefore, please take into consideration this transient current when selecting a switch. ■ Induction load Since arc generation due to reverse voltage can cause contact failure to occur when there is an induction load (in relays, solenoids and buzzers, etc.), we recommend you insert a suitable spark quenching circuit (see figure below). ■ Motor load Contacts may adhere due to the starting current at the start of motor operation which is three to eight times the steady-state current. Although it differs depending on the motor, since a current flows that is several times that of the nominal current, please select a switch taking into consideration the values in the table below. To make the motor rotate in reverse, use an ON- OFF-ON switch and take measures to prevent a multiplier current (starting current + reverse current) from flowing. A current that is approximately two times that of the starting current will flow when reverse rotation is caused during operation. Also, when using for a load that will cause transient phenomena such as when operating the motor in reverse rotation or switching the poles, an arc short (circuit short) may occur due to the time lag between poles when switching. Please be careful. ■ Capacitor load In the case of mercury lamps, florescent lamps and the capacitor loads of capacitor circuits, since an extremely large inrush current flows when the switch is turned on, please measure that transient value with the actual load and then either use the product keeping within the range of the rated current or after verifying the actual load. Circuit example Notes Switch contact (1) r = more than 10 Ω (2) In an AC circuit, impedance of R is to be slightly smaller than impedance of r and c. Switch contact Can be used for both AC and DC circuits. r = R C: 0.1 μF Switch contact For DC circuits only. Switch contact Can be used for both AC and DC circuits. rc R r c R Rdiode ZNR Varistor Induction load Motor type Type Starting current Three-phase induction motor Squirrel-cage Approx. 5 to 8 times current listed on nameplate Single-phase induction motor Split-phase-start Approx. 6 times current listed on nameplate Capacitor-start Approx. 4 to 5 times current listed on nameplate Repulsion-start Approx. 3 times current listed on nameplate Example of 1-pole motor reverse rotation circuit Good wiring Bad wiring Example of single-phase induction motor (capacitor) strong-weak switching circuit Good wiring Bad wiring Example of three-phase motor reverse rotation circuit Good wiring Bad wiring MM Power supply Power supply M M Power supply Weak Strong Strong Strong Strong Weak Weak Power supply Weak M M Power supply Power supply ー 5 ー
Technical Terminology & Cautions for Use AECTB38E 201811-T CAUTIONS FOR USE ■ Environment of use 1) Please consult us when using under the following conditions:
- Environments where hydrogen sulfide or other corrosive gases are present.
- Environments where gasoline, thinner or other flammable, explosive gases are present.
- Dusty environments (for non-seal type snap action switches).
- Use in environments not in the prescribed temperature or humidity range.
- Places with low air pressure. 2) Unless specified the product will not be constructed to withstand water, oil or explosions. Please inquire if you intend to use the product in special applications. ■ Usage, storage, and transport conditions 1) During usage, storage, or transportation, avoid locations subject to direct sunlight and maintain normal temperature, humidity, and pressure conditions. 2) The allowable specifications for environments suitable for usage, storage, and transportation are given below. (1) Temperature: The allowable temperature range differs for each switch, so refer to the switch’s individual specifications. (2) Humidity: 5 to 85% R.H. (3) Pressure: 86 to 106 kPa The humidity range varies with the temperature. Use within the range indicated in the graph below. (The allowable temperature depends on the switch.)
- Condensation will occur inside the switch if there is a sudden change in ambient temperature when used in an atmosphere of high temperature and high humidity. This is particularly likely to happen when being transported by ship, so please be careful of the atmosphere when shipping. Condensation is the phenomenon whereby steam condenses to cause water droplets that adhere to the switch when an atmosphere of high temperature and humidity rapidly changes from a high to low temperature or when the switch is quickly moved from a low humidity location to one of high temperature and humidity. Please be careful because condensation can cause adverse conditions such as deterioration of insulation, coil cutoff, and rust.
- Condensation or other moisture may freeze on the switch when the temperatures is lower than 0°C 32°F. This causes problems such as sticking of movable parts or operational time lags.
- The plastic becomes brittle if the switch is exposed to a low temperature, low humidity environment for long periods of time.
- Storage for extended periods of time (including transportation periods) at high temperatures or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and/or it may interfere with the functions. Check out the atmosphere in which the units are to be stored and transported.
- In terms of the packing format used, make every effort to keep the effects of moisture, organic gases and sulfide gases to the absolute minimum. ■ Wiring 1) When using a PC board terminal switch as soldering terminals, use thin lead wires and be sure to wind them on the terminals before soldering. 2) Cautions when soldering Perform soldering quickly in accordance with the specified conditions. Be careful not to let flux flow into the product. When no instruction is specified, use a soldering iron with a tip temperature of 350°C or lower and complete soldering within five seconds. Do not pull on the lead wires immediately after soldering. Wait some time before verifying. ■ Others 1) Failure modes of switches include short-circuiting, open- circuiting and temperature rises. If this switch is to be used in equipment where safety is a prime consideration, examine the possible effects of these failures on the equipment concerned, and ensure safety by providing protection circuits or protection devices. In terms of the systems involved, make provision for redundancy in the design and take steps to achieve safety design. 2) The ambient operating temperature (and humidity) range quoted is the range in which the switch can be operated on a continuous basis: it does not mean that using the switch within the rating guarantees the durability performance and environment withstanding performance of the switch. For details on the performance guarantee, check the specifications of each product concerned. 3) Even if 2-pole, 3-pole or 4-pole switches are used as single- pole switches in order to increase contact reliability, please keep the maximum current no higher than the rated value. 4) If there is the possibility of a short between poles, please use an in-phase circuit as shown below or provide a spare pole. 5) Be careful not to drop the product as this may cause loss of functionality. 6) Do not apply an unreasonable vertical force against the direction of operation of the product. 7) Use your hand to operate the actuator. (Operation using a tool such as a screwdriver or hammer can cause breakdown.) Tolerance range (Avoid condensation when used at temperatures higher than 0°C 32°F) (Avoid freezing when used at temperatures lower than 0°C 32°F) –40 –40 +32 +85 +185 Temperature, °C °F Humidity, %R.H. Bad example Good example (1) Good example (2) Load 1 Load 1 Heteropolar circuit In-phase circuit Load 2 Load 1 Spare pole Load 2 Load 2 ー 6 ー