ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com General Description The SV-series has been developed to follow ETA’s philosophy of “Miniaturization and high efficiency” of power supplies. There are two inputs available: SVM..-SA is designed for 100VAC; SVM-..SB is usable with 200VAC. The small size and high efficiency are suitable for many applications, especially small equipment. Application Features Industrial Input 1. Very small (one of the smallest in Japan) 2. No derating when mounted on a horizontal surface 3. Low impedance capacitors 4. Over voltage protection 5. EMI: Complies with FCC/A Options Input Voltage: Efficiency: AC85-132V 77%

15 WATT

Specifications<AC/DC> SVM**SA 15WATTS/SINGLE Input Voltage Input Range Input Frequency Input Frequency Range Phase Inrush Current *1 Efficiency [%] (typical) *2 80 81 82 84 84 Model SVM05SA SVM12SA SVM15SA SVM24SA SVM48SA 47-440Hz Single 20A(maximum)at AC100V Input Characteristic AC100V AC85-132V(DC110-175V) 50/60Hz

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Specifications<AC/DC> SVM**SA 15WATTS/SINGLE Output Voltage [V] 5 12 15 24 48 Voltage Adjust Range Ripple and Noise mVp-p *3 150 220 250 340 580 Regulation a.Statistic Line Regulation mV 40 96 120 192 384 b.Statistic Load Regulation mV 45 108 135 216 432 c.Temperature Coefficient *4 d.DriftmV *5 45 75 90 135 255 e.Dynamic Load Regulation mV *6 150 360 450 720 1440 f.Recovery Time *6 Rise up time Hold up time Remote Sense Remote On/Off Operating Temperature Operating Humidity Storage Temperature Storage Humidity Isolation Resistance Vibration Shock Cooling Leakage Current Safety Weight (typical) MTBF [H] Switching FrequencykHz *4 at 0 to +50℃ *5 for 7hour period after 1hour warm-up at 25℃ and rated input/output *6 when output current changed from 25% to 75% of rated output current rapidly at AC100V input Conditions: *1 at cold start *2 at DC130V input and rated output *3 measured by a bayonet probe at output connector at 0 to 100MHz bandwidth 120g 630,000 140 294m/s Convection 1mA(maximum) at 25℃,rated input/output and rated input frequency Primary-Secondary-Frame Ground 50MΩ(minimum) by DC500V insulation tester 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s ,20minutes' period for 60minutes each along X,Y,Z axes(non-operating) 85%RH(non-condensing) Withstanding Voltage Primary-Secondary AC1,500V for 1minute Primary-Frame Ground AC1,500V for 1minute Secondary-Frame Ground AC500V for 1minute Environmental 0 to +50℃ 85%RH(non-condensing) -20 to +85℃ Overvoltage Protection ≧110% of Rated Output Voltage[V] output shutdown(to reset,leave 1minute after shut-off) not available not available 500mS(maximum) at 25℃ and rated input/output 10mS(minimum) at 25℃ and rated input/output Functions Overcurrent Protection ≧110% of Rated Output Current[A] Current Limiting with automatic recovery +/-10% of Rated Output Voltage(at no load within the input range) 0.03%/℃ 0.3mS(typical) Model SVM05SA SVM12SA SVM15SA SVM24SA SVM48SA

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com DERATING CURVE DIMENSION DIAGRAM

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com OCP CURVE BLOCK DIAGRAM