ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 The Power Professionals ETA-USA SVA-SD
FEATURES
- Very small (one of the smallest in Japan)
- No derating when mounted on a horizontal surface
- Low impedance capacitors
- Over voltage protection
- EMI: Complies with FCC/A
- Isolated Power Supply Output Voltage 110V MODEL/CHANNEL OUTPUT (Single) SVA12SDSVA05SD SVA15SD SVA24SD SVA48SD Voltage Adjustment Range Rise Time Hold Up Time Ripple and Noise Recovery Time Temp Coefficient Line Regulation Drift Load Regulation Dynamic Lo ad Regulation Output Current Function Over Current Protection Over Voltage Protection 105% of Rated Output Current 115% of Rated Output voltage Reverse Voltage Protection 44115 0.51.11.72.15 +/-10% of Rated Output Voltage(at no load within input range) 0.03%/°C 255135905740 0.3mS(typical) Current Limiting with automatic recovery Output shutdown (to reset, leave 1 minute after shutdown) by internal bridge diode 52.8 0.551.21 26.416.5 1.872.31 13.2 5.5 5.5 1440 432 384 720450360150 192 216 120 135108 9640 580340250220150 10mS(minimum) at 25°C and rated input/output 500mS(maximum) at 25°C and rated input/output Unit Vdc mVp mV mV mV mVp A A
ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 The Power Professionals ETA-USA INPUT UnitMODEL/CHANNEL UnitMODEL/CHANNEL Dimension Environment mm/gSize(WxHxD) / Weight Operating Temperature Operating Humidity Storage Temperature Withstand Voltage Vibration Storage Humidity % -Primary-Secondary Isolation Resistance Shock Cooling %Efficiency kHzSwitching Frequency SVA12SDSVA05SD SVA15SD SVA24SD SVA48SD 0 to +50°C 85%RH(non-condensing) -20 to +85°C 85%RH (non-condensing) Primary-Secondary AC2,000V for 1 minute Primary-Frame Ground AC2,000V for 1 minute Secondary-Frame Ground AC500V for 1 minute Primary-Secondary-Frame Ground 50MΩ(minimum) by DC500V insulation tester 5-10Hz: 10mm double amplitude, 10-55Hz: 19.6m/s^2, 20 minutes period for 60 minutes each along X, Y, Z axes (non-operating) 294m/s^2 Convection 73Wx95Lx24H/220g 90 Fix. 8384828178 Input Voltage Range Vdc VdcInput Voltage 110V HRef. MTBF AInrush Current 590,000 DC110V DC85~140V 20A (maximum) at DC110V Efficiency Curve
ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 The Power Professionals ETA-USA Block Diagram 25WDimension Diagram (mm)