ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com The SV-series has been developed to follow ETA’s philosophy of “Miniaturization and high efficiency” of power supplies. There are two inputs available: SVA-SA is designed for 100VAC; SVA-..SB is usable with 200VAC. The small size and high efficiency are suitable for many applications, especially small equipment. Application Features Industrial Input 1. Very small (one of the smallest in Japan) 2. No derating when mounted on a horizontal surface 3. Low impedance capacitors Options Input Voltage Input Voltage Range: Frequency: Frequency Range: Phase: Inrush Current:*1, *4 AC115V AC85~132V; (DC110~370V) with 70V derating possibility 50/60 Hz 47~440 Hz Single 20A max at AC 100V Combination of wire and harness (40cm)
25 WATT
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Output Models Characteristic Unit SVA21FWA SVA22FWA SVA23FWA SVA24FWA-B Output Voltage Vdc +5 +24 +12 +12 +15 +15 +12 +5 Output Current A 2 1 2 1 1 1 2 1 Ripple &Noise(max) mVpp 50 240 120 120 150 150 120 50 Voltage Adjust Range V ±3% Rise time mS 100 Hold up time mS 20 Regulation a. Line Regulation [max] mV 40 192 96 96 120 120 96 40 b. Load Regulation mV 45 216 108 108 135 135 108 45 c. Temperature Coefficient 0.03% / °C d. Drift(maximum) mV 50 240 120 120 150 150 120 50 e. Dynamic Load Regulation (typ.) *2 mV 150 720 360 360 450 450 360 150 f. Recovery Time *2 mS 1mS Efficiency *1 % 78~80% typ. Power Factor *1 No power factor needed
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Environmental Specification Operating Temperature*3 0 to +60 °C Operating Humidity 20~85% RH Storage Temperature -20 to +85 °C Storage Humidity 10~95% RH Withstanding Voltage Primary-Secondary AC3,000V for 1minute Primary-Frame Ground AC2,500V for 1minute Secondary-Frame Ground AC1,000V for 1minute *Sensory Current: Secondary Frame Ground (20[mA])/Others (10[mA]) Isolation Resistance Primary-Secondary-Frame Ground 100M Ω(minimum) by DC500V insulation tester Vibration 5~10Hz:10mm double amplitude,10-55Hz:19.6m/s2,30 minute cycle each along X,Y,Z axes(non-operating) Shock 196 m/s2 on x,y,z axis Cooling Convection Leakage current 1mA max Environmental Agencies Line Conducted Noise [EMI] Built to meet FCC-B, VCCI-B, CISPR22-B, EN55022-B Line Harmonic Distortion/Current No information Safety UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178, UL508 CSA22.2 NO14-M95, CE EN60950-1 Function/Protection Over current Protection Operate at 110% min of rated current, automatic return Over voltage Protection No information Remote Sense Not Available Remote Control Not Available Mechanical Dimension [mm] 73W × 95L × 24H Weight g 200g
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com