ST7789V2 SITRONIX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 319
Technical content
Sitronix reserves the right to change the contents in this document without prior notice, please contact Sitronix to obtain the latest version of datasheet before placing your order. No responsibility is assumed by Sitronix for any infringement of patent or other rights of third parties which may result from its use. 2016 Sitronix Technology Corporation. All rights reserved. Version 1.0
Version 1.0 Page 2 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. LIST OF CONTENT
Version 1.0 Page 3 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.11 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”00b” . 78 8.8.12 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”01b” 8.8.13 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”10b” 8.8.14 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”11b” 8.8.17 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”00b” 8.8.18 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”01b” 8.8.19 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”10b” 8.8.20 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”11b”
Version 1.0 Page 4 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
Version 1.0 Page 5 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
Version 1.0 Page 6 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
Version 1.0 Page 7 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
Version 1.0 Page 8 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
Version 1.0 Page 11 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. LIST OF TABLES TABLE 16 AC CHARACTERISTICS OF T EARING E FFECT SIGNAL IDLE M ODE O FF (F RAME R ATE = 60 H Z , TA =25°C)
Version 1.0 Page 12 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
1 GENERAL DESCRIPTION
The ST7789V2 is a single-chip controller/driver for 262K-color, graphic type TFT-LCD. It consists of 720 source line and 320 gate line driving circuits. This chip can directly connect to an external microprocessor, and accepts, 8-bits/9-bits/16-bits/18-bits parallel interface. Display data can be stored in the on-chip display data RAM of 240x320x18 bits. It can perform display data RAM read/write operation with no external operation clock to minimize power consumption. In addition, because of the integrated power supply circuit necessary to drive liquid crystal; it is possible to make a display system with the fewest components.
Version 1.0 Page 13 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
2 FEATURES
/circle6 Single chip TFT-LCD Controller/Driver with On-chip Frame Memory (FM) /circle6 Display Resolution: 240*RGB (H) *320(V) /circle6 Frame Memory Size: 240 x 320 x 18-bit = 1,382,400 bits /circle6 LCD Driver Output Circuits - Source Outputs: 240 RGB Channels - Gate Outputs: 320 Channels - Common Electrode Output /circle6 Display Colors (Color Mode) - Full Color: 262K, RGB=(666) max., Idle Mode Off - Color Reduce: 8-color, RGB=(111), Idle Mode On /circle6 Programmable Pixel Color Format (Color Depth) for Various Display Data input Format - 12-bit/pixel: RGB=(444) - 16-bit/pixel: RGB=(565) - 18-bit/pixel: RGB=(666) /circle6 MCU Interface - Parallel 8080-series MCU Interface (8-bit, 9-bit, 16-bit & 18-bit) - 6/16/18 RGB Interface(VSYNC, HSYNC, DOTCLK, ENABL E, DB[17:0]) - Serial Peripheral Interface(SPI Interface) - VSYNC Interface /circle6 Display Features - Programmable Partial Display Duty - CABC for saving current consumption - Color enhancement /circle6 On Chip Build-In Circuits - DC/DC Converter - Adjustable VCOM Generation - Non-Volatile (NV) Memory to Store Initial Register Setting and Factory Default Value (Module ID, Module Version, etc) - Timing Controller - 4 preset Gamma curve with separated RGB Gamma setting /circle6 Build-In NV Memory for LCD Initial Register Setting - 8-bits for ID1 setting - 8-bits for ID2 setting - 8-bits for ID3 setting - 6-bits for VCOM Offset adjustment /circle6 Driving Algorithm
Version 1.0 Page 14 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. - Dot Inversion - Column Inversion /circle6 Wide Supply Voltage Range ≦I/O Voltage (VDDI to DGND): 1.65V ~ 3.3V (VDDI VDD) - Analog Voltage (VDD to AGND): 2.4V ~ 3.3V /circle6 On-Chip Power System - Source Voltage (VAP (GVDD) to VAN (GVCL)): +6.4~-4.6V - VCOM level: GND - Gate driver HIGH level (VGH to AGND): +12.2V ~ +14.97V - Gate driver LOW level (VGL to AGND): -12.5V ~ -7.16V /circle6 Optimized layout for COG Assembly /circle6 Operate temperature range: −30 ℃ to +85 ℃ /circle6 Lower Power Consumption
Version 1.0 Page 15 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. VCC VCC DUMMY VPP VPP VPP VPP DUMMY DUMMY VGH VGH VGH VGH VGH VGH VGH VGH DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY AGND AGND AGND AGND AGND AGND AGND AGND DUMMYR1 DUMMYR2 DUMMY DUMMY DUMMY DUMMY DUMMY Y X DUMMY DUMMY DUMMY G 1 G 3 G 5 G 7 G 9 G 11 G 13 S 1 S 2 S 3 S 4 S 5 S 6 S353 S354 S355 S356 S357 S358 S359 S360 S361 S362 S363 S364 S365 S366 S367 S368 S712 S713 S714 S715 S716 S717 S718 S719 S720 G320 G318 G316 G314 G312 G310 G308 G306 G12 G10 DUMMY DUMMY DUMMY DUMMY DUMMY VCOM VCOM VCOM VCOM VCOM VCOM VCOM VCOM DUMMY VAG VAG VDDS VDDS VDDGX VDDGX DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY VGL VGL VGL VGL VGL VGL AVDD AVDD AVDD AVDD AVDD AVDD AVDD AVCL AVCL AVCL AVCL AVCL AVCL AVCL VAN VAN DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY VAP VAP V20 V20 V20 V20 V20 V20 V20 DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY VDD VDD VDD VDD VDD VDD VDD VDD AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND DGND DGND DGND DGND DGND DGND DGND DGND TEST3 DUMMY DUMMY EXTC IM3 IM2 IM1 IM0 RESX CSX DCX WRX RDX TEST2 VSYNC HSYNC ENABLE DOTCLK DUMMY SDA DB0 DB1 DB2 DB3 TEST1 DB4 DB5 DB6 DB7 DUMMY DB8 DB9 DB10 DB11 DUMMY DB12 DB13 DB14 DB15 DUMMY DB16 DB17 TEST0 TE SDO LED_PWM LED_EN VDDI_LED VDDI_LED TE2 TESTO1 TESTO2 TESTO3 TESTO4 TESTO5 TESTO6 VDDI VDDI VDDI VDDI VDDI VDDI VDDI VCC VCC VCC VCC VCC VCC VCC VCC VCC VCC VCC VCC DUMMY DUMMY VCOM VCOM VCOM VCOM VCOM VCOM VCOM VCOM DUMMY DUMMY Bump View G303 G305 G307 G309 G311 G313 G315 G317 G319
3 PAD ARRANGEMENT
3.1 Output Bump Dimension
Au bump height 9 µm Au bump size 14 µmx100 µm Gate : G1~G320 Source : S1~S720 40 µmx56 µm Input Pads : Pad 12 to Pad 239
Version 1.0 Page 16 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
3.2 Input Bump Dimension
/circle6 Output Pads S1~S720 、G1~G320 、DUMMY (No.233~1278) /circle6 Input Pads No.1~232 E F G H Symbol Item Size A Bump Width 14 um B Bump Gap 1 (Horizontal) 14 um C Bump Height 100 um D Bump Gap 2 (Vertical) 31 um Symbol Item Size E Bump Width 40 um F Bump Gap 20 、32.5 、45 um G Bump Height 56 um H Bump Pitch 60 、72.5 、85 um
Version 1.0 Page 17 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
3.3 Alignment Mark Dimension
/circle6 Alignment Mark : A1(X,Y)=(-7480,251.58) 30 30 30 10 10 /circle6 Alignment Mark : A2(X,Y)=(+7480,251.58) 30 30 30 20 10 10 10
3.4 Chip Information
Chip size 15155 µm x698 µm Chip thickness 300 µm Pad Location Pad center Coordinate Origin Chip center
Version 1.0 Page 18 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
4 PAD CENTER COORDINATES
No. PIN Name X Y 1 DUMMY -7292.5 -256.62 2 DUMMY -7232.5 -256.62 3 VCOM -7172.5 -256.62 4 VCOM -7112.5 -256.62 5 VCOM -7052.5 -256.62 6 VCOM -6992.5 -256.62 7 VCOM -6932.5 -256.62 8 VCOM -6872.5 -256.62 9 VCOM -6812.5 -256.62 10 VCOM -6752.5 -256.62 11 DUMMY -6692.5 -256.62 12 VAG -6632.5 -256.62 13 VAG -6572.5 -256.62 14 VDDS -6512.5 -256.62 15 VDDS -6452.5 -256.62 16 VDDGX -6392.5 -256.62 17 VDDGX -6332.5 -256.62 18 DUMMY -6272.5 -256.62 19 DUMMY -6212.5 -256.62 20 DUMMY -6152.5 -256.62 21 DUMMY -6092.5 -256.62 22 DUMMY -6032.5 -256.62 23 DUMMY -5972.5 -256.62 24 DUMMY -5912.5 -256.62 25 DUMMY -5852.5 -256.62 26 VGL -5792.5 -256.62 27 VGL -5732.5 -256.62 28 VGL -5672.5 -256.62 29 VGL -5612.5 -256.62 30 VGL -5552.5 -256.62 31 VGL -5492.5 -256.62 32 AVDD -5432.5 -256.62 PAD No. PIN Name X Y 33 AVDD -5372.5 -256.62 34 AVDD -5312.5 -256.62 35 AVDD -5252.5 -256.62 36 AVDD -5192.5 -256.62 37 AVDD -5132.5 -256.62 38 AVDD -5072.5 -256.62 39 AVCL -5012.5 -256.62 40 AVCL -4952.5 -256.62 41 AVCL -4892.5 -256.62 42 AVCL -4832.5 -256.62 43 AVCL -4772.5 -256.62 44 AVCL -4712.5 -256.62 45 AVCL -4652.5 -256.62 46 VAN -4592.5 -256.62 47 VAN -4532.5 -256.62 48 DUMMY -4472.5 -256.62 49 DUMMY -4412.5 -256.62 50 DUMMY -4352.5 -256.62 51 DUMMY -4292.5 -256.62 52 DUMMY -4232.5 -256.62 53 DUMMY -4172.5 -256.62 54 DUMMY -4112.5 -256.62 55 DUMMY -4052.5 -256.62 56 DUMMY -3992.5 -256.62 57 DUMMY -3932.5 -256.62 58 VAP -3872.5 -256.62 59 VAP -3812.5 -256.62 60 V20 -3752.5 -256.62 61 V20 -3692.5 -256.62 62 V20 -3632.5 -256.62 63 V20 -3572.5 -256.62 64 V20 -3512.5 -256.62 PAD No. PIN Name X Y 65 V20 -3452.5 -256.62 66 V20 -3392.5 -256.62 67 DUMMY -3332.5 -256.62 68 DUMMY -3272.5 -256.62 69 DUMMY -3212.5 -256.62 70 DUMMY -3152.5 -256.62 71 DUMMY -3092.5 -256.62 72 DUMMY -3032.5 -256.62 73 DUMMY -2972.5 -256.62 74 VDD -2912.5 -256.62 75 VDD -2852.5 -256.62 76 VDD -2792.5 -256.62 77 VDD -2732.5 -256.62 78 VDD -2672.5 -256.62 79 VDD -2612.5 -256.62 80 VDD -2552.5 -256.62 81 VDD -2492.5 -256.62 82 AGND -2432.5 -256.62 83 AGND -2372.5 -256.62 84 AGND -2312.5 -256.62 85 AGND -2252.5 -256.62 86 AGND -2192.5 -256.62 87 AGND -2132.5 -256.62 88 AGND -2072.5 -256.62 89 AGND -2012.5 -256.62 90 AGND -1952.5 -256.62 91 AGND -1892.5 -256.62 92 AGND -1832.5 -256.62 93 AGND -1772.5 -256.62 94 AGND -1712.5 -256.62 95 AGND -1652.5 -256.62 96 AGND -1592.5 -256.62
Version 1.0 Page 19 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. PAD No. PIN Name X Y 97 AGND -1532.5 -256.62 98 DGND -1472.5 -256.62 99 DGND -1412.5 -256.62 100 DGND -1352.5 -256.62 101 DGND -1292.5 -256.62 102 DGND -1232.5 -256.62 103 DGND -1172.5 -256.62 104 DGND -1112.5 -256.62 105 DGND -1052.5 -256.62 106 TEST3 -992.5 -256.62 107 DUMMY -932.5 -256.62 108 DUMMY -872.5 -256.62 109 EXTC -812.5 -256.62 110 IM3 -752.5 -256.62 111 IM2 -692.5 -256.62 112 IM1 -632.5 -256.62 113 IM0 -572.5 -256.62 114 RESX -512.5 -256.62 115 CSX -452.5 -256.62 116 DCX -392.5 -256.62 117 WRX -332.5 -256.62 118 RDX -272.5 -256.62 119 TEST2 -212.5 -256.62 120 VSYNC -152.5 -256.62 121 HSYNC -92.5 -256.62 122 ENABLE -32.5 -256.62 123 DOTCLK 27.5 -256.62 124 DUMMY 87.5 -256.62 125 SDA 160 -256.62 126 DB0 245 -256.62 127 DB1 330 -256.62 128 DB2 415 -256.62 129 DB3 500 -256.62 130 TEST1 572.5 -256.62 PAD No. PIN Name X Y 131 DB4 645 -256.62 132 DB5 730 -256.62 133 DB6 815 -256.62 134 DB7 900 -256.62 135 DUMMY 972.5 -256.62 136 DB8 1045 -256.62 137 DB9 1130 -256.62 138 DB10 1215 -256.62 139 DB11 1300 -256.62 140 DUMMY 1372.5 -256.62 141 DB12 1445 -256.62 142 DB13 1530 -256.62 143 DB14 1615 -256.62 144 DB15 1700 -256.62 145 DUMMY 1772.5 -256.62 146 DB16 1845 -256.62 147 DB17 1930 -256.62 148 TEST0 2002.5 -256.62 149 TE 2075 -256.62 150 SDO 2160 -256.62 151 LED_PWM 2245 -256.62 152 LED_EN 2330 -256.62 153 VDDI_LED 2402.5 -256.62 154 VDDI_LED 2462.5 -256.62 155 TE2 2535 -256.62 156 TESTO1 2620 -256.62 157 TESTO2 2705 -256.62 158 TESTO3 2790 -256.62 159 TESTO4 2875 -256.62 160 TESTO5 2960 -256.62 161 TESTO6 3032.5 -256.62 162 VDDI 3092.5 -256.62 163 VDDI 3152.5 -256.62 164 VDDI 3212.5 -256.62 PAD No. PIN Name X Y 165 VDDI 3272.5 -256.62 166 VDDI 3332.5 -256.62 167 VDDI 3392.5 -256.62 168 VDDI 3452.5 -256.62 169 VCC 3512.5 -256.62 170 VCC 3572.5 -256.62 171 VCC 3632.5 -256.62 172 VCC 3692.5 -256.62 173 VCC 3752.5 -256.62 174 VCC 3812.5 -256.62 175 VCC 3872.5 -256.62 176 VCC 3932.5 -256.62 177 VCC 3992.5 -256.62 178 VCC 4052.5 -256.62 179 VCC 4112.5 -256.62 180 VCC 4172.5 -256.62 181 VCC 4232.5 -256.62 182 VCC 4292.5 -256.62 183 DUMMY 4352.5 -256.62 184 VPP 4412.5 -256.62 185 VPP 4472.5 -256.62 186 VPP 4532.5 -256.62 187 VPP 4592.5 -256.62 188 DUMMY 4652.5 -256.62 189 DUMMY 4712.5 -256.62 190 VGH 4772.5 -256.62 191 VGH 4832.5 -256.62 192 VGH 4892.5 -256.62 193 VGH 4952.5 -256.62 194 VGH 5012.5 -256.62 195 VGH 5072.5 -256.62 196 VGH 5132.5 -256.62 197 VGH 5192.5 -256.62 198 DUMMY 5252.5 -256.62
Version 1.0 Page 20 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. PAD No. PIN Name X Y 199 DUMMY 5312.5 -256.62 200 DUMMY 5372.5 -256.62 201 DUMMY 5432.5 -256.62 202 DUMMY 5492.5 -256.62 203 DUMMY 5552.5 -256.62 204 DUMMY 5612.5 -256.62 205 DUMMY 5672.5 -256.62 206 AGND 5732.5 -256.62 207 AGND 5792.5 -256.62 208 AGND 5852.5 -256.62 209 AGND 5912.5 -256.62 210 AGND 5972.5 -256.62 211 AGND 6032.5 -256.62 212 AGND 6092.5 -256.62 213 AGND 6152.5 -256.62 214 DUMMYR1 6212.5 -256.62 215 DUMMYR2 6272.5 -256.62 216 DUMMY 6332.5 -256.62 217 DUMMY 6392.5 -256.62 218 DUMMY 6452.5 -256.62 219 DUMMY 6512.5 -256.62 220 DUMMY 6572.5 -256.62 221 DUMMY 6632.5 -256.62 222 DUMMY 6692.5 -256.62 223 VCOM 6752.5 -256.62 224 VCOM 6812.5 -256.62 225 VCOM 6872.5 -256.62 226 VCOM 6932.5 -256.62 227 VCOM 6992.5 -256.62 228 VCOM 7052.5 -256.62 229 VCOM 7112.5 -256.62 230 VCOM 7172.5 -256.62 231 DUMMY 7232.5 -256.62 232 DUMMY 7292.5 -256.62 PAD No. PIN Name X Y 233 DUMMY 7399 250.58 234 DUMMY 7385 119.58 235 DUMMY 7371 250.58 236 G2 7357 119.58 237 G4 7343 250.58 238 G6 7329 119.58 239 G8 7315 250.58 240 G10 7301 119.58 241 G12 7287 250.58 242 G14 7273 119.58 243 G16 7259 250.58 244 G18 7245 119.58 245 G20 7231 250.58 246 G22 7217 119.58 247 G24 7203 250.58 248 G26 7189 119.58 249 G28 7175 250.58 250 G30 7161 119.58 251 G32 7147 250.58 252 G34 7133 119.58 253 G36 7119 250.58 254 G38 7105 119.58 255 G40 7091 250.58 250.58 G42 7077 119.58 257 G44 7063 250.58 258 G46 7049 119.58 259 G48 7035 250.58 260 G50 7021 119.58 261 G52 7007 250.58 262 G54 6993 119.58 263 G56 6979 250.58 264 G58 6965 119.58 265 G60 6951 250.58 266 G62 6937 119.58 PAD No. PIN Name X Y 267 G64 6923 250.58 268 G66 6909 119.58 269 G68 6895 250.58 270 G70 6881 119.58 271 G72 6867 250.58 272 G74 6853 119.58 273 G76 6839 250.58 274 G78 6825 119.58 275 G80 6811 250.58 276 G82 6797 119.58 277 G84 6783 250.58 278 G86 6769 119.58 279 G88 6755 250.58 280 G90 6741 119.58 281 G92 6727 250.58 282 G94 6713 119.58 283 G96 6699 250.58 284 G98 6685 119.58 285 G100 6671 250.58 286 G102 6657 119.58 287 G104 6643 250.58 288 G106 6629 119.58 289 G108 6615 250.58 290 G110 6601 119.58 291 G112 6587 250.58 292 G114 6573 119.58 293 G116 6559 250.58 294 G118 6545 119.58 295 G120 6531 250.58 296 G122 6517 119.58 297 G124 6503 250.58 298 G126 6489 119.58 299 G128 6475 250.58 300 G130 6461 119.58
Version 1.0 Page 21 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. PAD No. PIN Name X Y 301 G132 6447 250.58 302 G134 6433 119.58 303 G136 6419 250.58 304 G138 6405 119.58 305 G140 6391 250.58 306 G142 6377 119.58 307 G144 6363 250.58 308 G146 6349 119.58 309 G148 6335 250.58 310 G150 6321 119.58 311 G152 6307 250.58 312 G154 6293 119.58 313 G156 6279 250.58 314 G158 6265 119.58 315 G160 6251 250.58 316 G162 6237 119.58 317 G164 6223 250.58 318 G166 6209 119.58 319 G168 6195 250.58 320 G170 6181 119.58 321 G172 6167 250.58 322 G174 6153 119.58 323 G176 6139 250.58 324 G178 6125 119.58 325 G180 6111 250.58 326 G182 6097 119.58 327 G184 6083 250.58 328 G186 6069 119.58 329 G188 6055 250.58 330 G190 6041 119.58 331 G192 6027 250.58 332 G194 6013 119.58 333 G196 5999 250.58 334 G198 5985 119.58 PAD No. PIN Name X Y 335 G200 5971 250.58 336 G202 5957 119.58 337 G204 5943 250.58 338 G206 5929 119.58 339 G208 5915 250.58 340 G210 5901 119.58 341 G212 5887 250.58 342 G214 5873 119.58 343 G216 5859 250.58 344 G218 5845 119.58 345 G220 5831 250.58 346 G222 5817 119.58 347 G224 5803 250.58 348 G226 5789 119.58 349 G228 5775 250.58 350 G230 5761 119.58 351 G232 5747 250.58 352 G234 5733 119.58 353 G236 5719 250.58 354 G238 5705 119.58 355 G240 5691 250.58 356 G242 5677 119.58 357 G244 5663 250.58 358 G246 5649 119.58 359 G248 5635 250.58 360 G250 5621 119.58 361 G252 5607 250.58 362 G254 5593 119.58 363 G256 5579 250.58 364 G258 5565 119.58 365 G260 5551 250.58 366 G262 5537 119.58 367 G264 5523 250.58 368 G266 5509 119.58 PAD No. PIN Name X Y 369 G268 5495 250.58 370 G270 5481 119.58 371 G272 5467 250.58 372 G274 5453 119.58 373 G276 5439 250.58 374 G278 5425 119.58 375 G280 5411 250.58 376 G282 5397 119.58 377 G284 5383 250.58 378 G286 5369 119.58 379 G288 5355 250.58 380 G290 5341 119.58 381 G292 5327 250.58 382 G294 5313 119.58 383 G296 5299 250.58 384 G298 5285 119.58 385 G300 5271 250.58 386 G302 5257 119.58 387 G304 5243 250.58 388 G306 5229 119.58 389 G308 5215 250.58 390 G310 5201 119.58 391 G312 5187 250.58 392 G314 5173 119.58 393 G316 5159 250.58 394 G318 5145 119.58 395 G320 5131 250.58 396 S720 5075 119.58 397 S719 5061 250.58 398 S718 5047 119.58 399 S717 5033 250.58 400 S716 5019 119.58 401 S715 5005 250.58 402 S714 4991 119.58
Version 1.0 Page 22 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. PAD No. PIN Name X Y 403 S713 4977 250.58 404 S712 4963 119.58 405 S711 4949 250.58 406 S710 4935 119.58 407 S709 4921 250.58 408 S708 4907 119.58 409 S707 4893 250.58 410 S706 4879 119.58 411 S705 4865 250.58 412 S704 4851 119.58 413 S703 4837 250.58 414 S702 4823 119.58 415 S701 4809 250.58 416 S700 4795 119.58 417 S699 4781 250.58 418 S698 4767 119.58 419 S697 4753 250.58 420 S696 4739 119.58 421 S695 4725 250.58 422 S694 4711 119.58 423 S693 4697 250.58 424 S692 4683 119.58 425 S691 4669 250.58 426 S690 4655 119.58 427 S689 4641 250.58 428 S688 4627 119.58 429 S687 4613 250.58 430 S686 4599 119.58 431 S685 4585 250.58 432 S684 4571 119.58 433 S683 4557 250.58 434 S682 4543 119.58 435 S681 4529 250.58 436 S680 4515 119.58 PAD No. PIN Name X Y 437 S679 4501 250.58 438 S678 4487 119.58 439 S677 4473 250.58 440 S676 4459 119.58 441 S675 4445 250.58 442 S674 4431 119.58 443 S673 4417 250.58 444 S672 4403 119.58 445 S671 4389 250.58 446 S670 4375 119.58 447 S669 4361 250.58 448 S668 4347 119.58 449 S667 4333 250.58 450 S666 4319 119.58 451 S665 4305 250.58 452 S664 4291 119.58 453 S663 4277 250.58 454 S662 4263 119.58 455 S661 4249 250.58 456 S660 4235 119.58 457 S659 4221 250.58 458 S658 4207 119.58 459 S657 4193 250.58 460 S656 4179 119.58 461 S655 4165 250.58 462 S654 4151 119.58 463 S653 4137 250.58 464 S652 4123 119.58 465 S651 4109 250.58 466 S650 4095 119.58 467 S649 4081 250.58 468 S648 4067 119.58 469 S647 4053 250.58 470 S646 4039 119.58 PAD No. PIN Name X Y 471 S645 4025 250.58 472 S644 4011 119.58 473 S643 3997 250.58 474 S642 3983 119.58 475 S641 3969 250.58 476 S640 3955 119.58 477 S639 3941 250.58 478 S638 3927 119.58 479 S637 3913 250.58 480 S636 3899 119.58 481 S635 3885 250.58 482 S634 3871 119.58 483 S633 3857 250.58 484 S632 3843 119.58 485 S631 3829 250.58 486 S630 3815 119.58 487 S629 3801 250.58 488 S628 3787 119.58 489 S627 3773 250.58 490 S626 3759 119.58 491 S625 3745 250.58 492 S624 3731 119.58 493 S623 3717 250.58 494 S622 3703 119.58 495 S621 3689 250.58 496 S620 3675 119.58 497 S619 3661 250.58 498 S618 3647 119.58 499 S617 3633 250.58 500 S616 3619 119.58 501 S615 3605 250.58 502 S614 3591 119.58 503 S613 3577 250.58 504 S612 3563 119.58
Version 1.0 Page 23 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. PAD No. PIN Name X Y 505 S611 3549 250.58 506 S610 3535 119.58 507 S609 3521 250.58 508 S608 3507 119.58 509 S607 3493 250.58 510 S606 3479 119.58 511 S605 3465 250.58 512 S604 3451 119.58 513 S603 3437 250.58 514 S602 3423 119.58 515 S601 3409 250.58 516 S600 3395 119.58 517 S599 3381 250.58 518 S598 3367 119.58 519 S597 3353 250.58 520 S596 3339 119.58 521 S595 3325 250.58 522 S594 3311 119.58 523 S593 3297 250.58 524 S592 3283 119.58 525 S591 3269 250.58 526 S590 3255 119.58 527 S589 3241 250.58 528 S588 3227 119.58 529 S587 3213 250.58 530 S586 3199 119.58 531 S585 3185 250.58 532 S584 3171 119.58 533 S583 3157 250.58 534 S582 3143 119.58 535 S581 3129 250.58 536 S580 3115 119.58 537 S579 3101 250.58 538 S578 3087 119.58 PAD No. PIN Name X Y 539 S577 3073 250.58 540 S576 3059 119.58 541 S575 3045 250.58 542 S574 3031 119.58 543 S573 3017 250.58 544 S572 3003 119.58 545 S571 2989 250.58 546 S570 2975 119.58 547 S569 2961 250.58 548 S568 2947 119.58 549 S567 2933 250.58 550 S566 2919 119.58 551 S565 2905 250.58 552 S564 2891 119.58 553 S563 2877 250.58 554 S562 2863 119.58 555 S561 2849 250.58 556 S560 2835 119.58 557 S559 2821 250.58 558 S558 2807 119.58 559 S557 2793 250.58 560 S556 2779 119.58 561 S555 2765 250.58 562 S554 2751 119.58 563 S553 2737 250.58 564 S552 2723 119.58 565 S551 2709 250.58 566 S550 2695 119.58 567 S549 2681 250.58 568 S548 2667 119.58 569 S547 2653 250.58 570 S546 2639 119.58 571 S545 2625 250.58 572 S544 2611 119.58 PAD No. PIN Name X Y 573 S543 2597 250.58 574 S542 2583 119.58 575 S541 2569 250.58 576 S540 2555 119.58 577 S539 2541 250.58 578 S538 2527 119.58 579 S537 2513 250.58 580 S536 2499 119.58 581 S535 2485 250.58 582 S534 2471 119.58 583 S533 2457 250.58 584 S532 2443 119.58 585 S531 2429 250.58 586 S530 2415 119.58 587 S529 2401 250.58 588 S528 2387 119.58 589 S527 2373 250.58 590 S526 2359 119.58 591 S525 2345 250.58 592 S524 2331 119.58 593 S523 2317 250.58 594 S522 2303 119.58 595 S521 2289 250.58 596 S520 2275 119.58 597 S519 2261 250.58 598 S518 2247 119.58 599 S517 2233 250.58 600 S516 2219 119.58 601 S515 2205 250.58 602 S514 2191 119.58 603 S513 2177 250.58 604 S512 2163 119.58 605 S511 2149 250.58 606 S510 2135 119.58
Version 1.0 Page 24 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. PAD No. PIN Name X Y 607 S509 2121 250.58 608 S508 2107 119.58 609 S507 2093 250.58 610 S506 2079 119.58 611 S505 2065 250.58 612 S504 2051 119.58 613 S503 2037 250.58 614 S502 2023 119.58 615 S501 2009 250.58 616 S500 1995 119.58 617 S499 1981 250.58 618 S498 1967 119.58 619 S497 1953 250.58 620 S496 1939 119.58 621 S495 1925 250.58 622 S494 1911 119.58 623 S493 1897 250.58 624 S492 1883 119.58 625 S491 1869 250.58 626 S490 1855 119.58 627 S489 1841 250.58 628 S488 1827 119.58 629 S487 1813 250.58 630 S486 1799 119.58 631 S485 1785 250.58 632 S484 1771 119.58 633 S483 1757 250.58 634 S482 1743 119.58 635 S481 1729 250.58 636 S480 1715 119.58 637 S479 1701 250.58 638 S478 1687 119.58 639 S477 1673 250.58 640 S476 1659 119.58 PAD No. PIN Name X Y 641 S475 1645 250.58 642 S474 1631 119.58 643 S473 1617 250.58 644 S472 1603 119.58 645 S471 1589 250.58 646 S470 1575 119.58 647 S469 1561 250.58 648 S468 1547 119.58 649 S467 1533 250.58 650 S466 1519 119.58 651 S465 1505 250.58 652 S464 1491 119.58 653 S463 1477 250.58 654 S462 1463 119.58 655 S461 1449 250.58 656 S460 1435 119.58 657 S459 1421 250.58 658 S458 1407 119.58 659 S457 1393 250.58 660 S456 1379 119.58 661 S455 1365 250.58 662 S454 1351 119.58 663 S453 1337 250.58 664 S452 1323 119.58 665 S451 1309 250.58 666 S450 1295 119.58 667 S449 1281 250.58 668 S448 1267 119.58 669 S447 1253 250.58 670 S446 1239 119.58 671 S445 1225 250.58 672 S444 1211 119.58 673 S443 1197 250.58 674 S442 1183 119.58 PAD No. PIN Name X Y 675 S441 1169 250.58 676 S440 1155 119.58 677 S439 1141 250.58 678 S438 1127 119.58 679 S437 1113 250.58 680 S436 1099 119.58 681 S435 1085 250.58 682 S434 1071 119.58 683 S433 1057 250.58 684 S432 1043 119.58 685 S431 1029 250.58 686 S430 1015 119.58 687 S429 1001 250.58 688 S428 987 119.58 689 S427 973 250.58 690 S426 959 119.58 691 S425 945 250.58 692 S424 931 119.58 693 S423 917 250.58 694 S422 903 119.58 695 S421 889 250.58 696 S420 875 119.58 697 S419 861 250.58 698 S418 847 119.58 699 S417 833 250.58 700 S416 819 119.58 701 S415 805 250.58 702 S414 791 119.58 703 S413 777 250.58 704 S412 763 119.58 705 S411 749 250.58 706 S410 735 119.58 707 S409 721 250.58 708 S408 707 119.58
Version 1.0 Page 25 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. PAD No. PIN Name X Y 709 S407 693 250.58 710 S406 679 119.58 711 S405 665 250.58 712 S404 651 119.58 713 S403 637 250.58 714 S402 623 119.58 715 S401 609 250.58 716 S400 595 119.58 717 S399 581 250.58 718 S398 567 119.58 719 S397 553 250.58 720 S396 539 119.58 721 S395 525 250.58 722 S394 511 119.58 723 S393 497 250.58 724 S392 483 119.58 725 S391 469 250.58 726 S390 455 119.58 727 S389 441 250.58 728 S388 427 119.58 729 S387 413 250.58 730 S386 399 119.58 731 S385 385 250.58 732 S384 371 119.58 733 S383 357 250.58 734 S382 343 119.58 735 S381 329 250.58 736 S380 315 119.58 737 S379 301 250.58 738 S378 287 119.58 739 S377 273 250.58 740 S376 259 119.58 741 S375 245 250.58 742 S374 231 119.58 PAD No. PIN Name X Y 743 S373 217 250.58 744 S372 203 119.58 745 S371 189 250.58 746 S370 175 119.58 747 S369 161 250.58 748 S368 147 119.58 749 S367 133 250.58 750 S366 119 119.58 751 S365 105 250.58 752 S364 91 119.58 753 S363 77 250.58 754 S362 63 119.58 755 S361 49 250.58 756 S360 -49 119.58 757 S359 -63 250.58 758 S358 -77 119.58 759 S357 -91 250.58 760 S356 -105 119.58 761 S355 -119 250.58 762 S354 -133 119.58 763 S353 -147 250.58 764 S352 -161 119.58 765 S351 -175 250.58 766 S350 -189 119.58 767 S349 -203 250.58 768 S348 -217 119.58 769 S347 -231 250.58 770 S346 -245 119.58 771 S345 -259 250.58 772 S344 -273 119.58 773 S343 -287 250.58 774 S342 -301 119.58 775 S341 -315 250.58 776 S340 -329 119.58 PAD No. PIN Name X Y 777 S339 -343 250.58 778 S338 -357 119.58 779 S337 -371 250.58 780 S336 -385 119.58 781 S335 -399 250.58 782 S334 -413 119.58 783 S333 -427 250.58 784 S332 -441 119.58 785 S331 -455 250.58 786 S330 -469 119.58 787 S329 -483 250.58 788 S328 -497 119.58 789 S327 -511 250.58 790 S326 -525 119.58 791 S325 -539 250.58 792 S324 -553 119.58 793 S323 -567 250.58 794 S322 -581 119.58 795 S321 -595 250.58 796 S320 -609 119.58 797 S319 -623 250.58 798 S318 -637 119.58 799 S317 -651 250.58 800 S316 -665 119.58 801 S315 -679 250.58 802 S314 -693 119.58 803 S313 -707 250.58 804 S312 -721 119.58 805 S311 -735 250.58 806 S310 -749 119.58 807 S309 -763 250.58 808 S308 -777 119.58 809 S307 -791 250.58 810 S306 -805 119.58
Version 1.0 Page 26 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. PAD No. PIN Name X Y 811 S305 -819 250.58 812 S304 -833 119.58 813 S303 -847 250.58 814 S302 -861 119.58 815 S301 -875 250.58 816 S300 -889 119.58 817 S299 -903 250.58 818 S298 -917 119.58 819 S297 -931 250.58 820 S296 -945 119.58 821 S295 -959 250.58 822 S294 -973 119.58 823 S293 -987 250.58 824 S292 -1001 119.58 825 S291 -1015 250.58 826 S290 -1029 119.58 827 S289 -1043 250.58 828 S288 -1057 119.58 829 S287 -1071 250.58 830 S286 -1085 119.58 831 S285 -1099 250.58 832 S284 -1113 119.58 833 S283 -1127 250.58 834 S282 -1141 119.58 835 S281 -1155 250.58 836 S280 -1169 119.58 837 S279 -1183 250.58 838 S278 -1197 119.58 839 S277 -1211 250.58 840 S276 -1225 119.58 841 S275 -1239 250.58 842 S274 -1253 119.58 843 S273 -1267 250.58 844 S272 -1281 119.58 PAD No. PIN Name X Y 845 S271 -1295 250.58 846 S270 -1309 119.58 847 S269 -1323 250.58 848 S268 -1337 119.58 849 S267 -1351 250.58 850 S266 -1365 119.58 851 S265 -1379 250.58 852 S264 -1393 119.58 853 S263 -1407 250.58 854 S262 -1421 119.58 855 S261 -1435 250.58 856 S260 -1449 119.58 857 S259 -1463 250.58 858 S258 -1477 119.58 859 S257 -1491 250.58 860 S256 -1505 119.58 861 S255 -1519 250.58 862 S254 -1533 119.58 863 S253 -1547 250.58 864 S252 -1561 119.58 865 S251 -1575 250.58 866 S250 -1589 119.58 867 S249 -1603 250.58 868 S248 -1617 119.58 869 S247 -1631 250.58 870 S246 -1645 119.58 871 S245 -1659 250.58 872 S244 -1673 119.58 873 S243 -1687 250.58 874 S242 -1701 119.58 875 S241 -1715 250.58 876 S240 -1729 119.58 877 S239 -1743 250.58 878 S238 -1757 119.58 PAD No. PIN Name X Y 879 S237 -1771 250.58 880 S236 -1785 119.58 881 S235 -1799 250.58 882 S234 -1813 119.58 883 S233 -1827 250.58 884 S232 -1841 119.58 885 S231 -1855 250.58 886 S230 -1869 119.58 887 S229 -1883 250.58 888 S228 -1897 119.58 889 S227 -1911 250.58 890 S226 -1925 119.58 891 S225 -1939 250.58 892 S224 -1953 119.58 893 S223 -1967 250.58 894 S222 -1981 119.58 895 S221 -1995 250.58 896 S220 -2009 119.58 897 S219 -2023 250.58 898 S218 -2037 119.58 899 S217 -2051 250.58 900 S216 -2065 119.58 901 S215 -2079 250.58 902 S214 -2093 119.58 903 S213 -2107 250.58 904 S212 -2121 119.58 905 S211 -2135 250.58 906 S210 -2149 119.58 907 S209 -2163 250.58 908 S208 -2177 119.58 909 S207 -2191 250.58 910 S206 -2205 119.58 911 S205 -2219 250.58 912 S204 -2233 119.58
Version 1.0 Page 27 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. PAD No. PIN Name X Y 913 S203 -2247 250.58 914 S202 -2261 119.58 915 S201 -2275 250.58 916 S200 -2289 119.58 917 S199 -2303 250.58 918 S198 -2317 119.58 919 S197 -2331 250.58 920 S196 -2345 119.58 921 S195 -2359 250.58 922 S194 -2373 119.58 923 S193 -2387 250.58 924 S192 -2401 119.58 925 S191 -2415 250.58 926 S190 -2429 119.58 927 S189 -2443 250.58 928 S188 -2457 119.58 929 S187 -2471 250.58 930 S186 -2485 119.58 931 S185 -2499 250.58 932 S184 -2513 119.58 933 S183 -2527 250.58 934 S182 -2541 119.58 935 S181 -2555 250.58 936 S180 -2569 119.58 937 S179 -2583 250.58 938 S178 -2597 119.58 939 S177 -2611 250.58 940 S176 -2625 119.58 941 S175 -2639 250.58 942 S174 -2653 119.58 943 S173 -2667 250.58 944 S172 -2681 119.58 945 S171 -2695 250.58 946 S170 -2709 119.58 PAD No. PIN Name X Y 947 S169 -2723 250.58 948 S168 -2737 119.58 949 S167 -2751 250.58 950 S166 -2765 119.58 951 S165 -2779 250.58 952 S164 -2793 119.58 953 S163 -2807 250.58 954 S162 -2821 119.58 955 S161 -2835 250.58 956 S160 -2849 119.58 957 S159 -2863 250.58 958 S158 -2877 119.58 959 S157 -2891 250.58 960 S156 -2905 119.58 961 S155 -2919 250.58 962 S154 -2933 119.58 963 S153 -2947 250.58 964 S152 -2961 119.58 965 S151 -2975 250.58 966 S150 -2989 119.58 967 S149 -3003 250.58 968 S148 -3017 119.58 969 S147 -3031 250.58 970 S146 -3045 119.58 971 S145 -3059 250.58 972 S144 -3073 119.58 973 S143 -3087 250.58 974 S142 -3101 119.58 975 S141 -3115 250.58 976 S140 -3129 119.58 977 S139 -3143 250.58 978 S138 -3157 119.58 979 S137 -3171 250.58 980 S136 -3185 119.58 PAD No. PIN Name X Y 981 S135 -3199 250.58 982 S134 -3213 119.58 983 S133 -3227 250.58 984 S132 -3241 119.58 985 S131 -3255 250.58 986 S130 -3269 119.58 987 S129 -3283 250.58 988 S128 -3297 119.58 989 S127 -3311 250.58 990 S126 -3325 119.58 991 S125 -3339 250.58 992 S124 -3353 119.58 993 S123 -3367 250.58 994 S122 -3381 119.58 995 S121 -3395 250.58 996 S120 -3409 119.58 997 S119 -3423 250.58 998 S118 -3437 119.58 999 S117 -3451 250.58 1000 S116 -3465 119.58 1001 S115 -3479 250.58 1002 S114 -3493 119.58 1003 S113 -3507 250.58 1004 S112 -3521 119.58 1005 S111 -3535 250.58 1006 S110 -3549 119.58 1007 S109 -3563 250.58 1008 S108 -3577 119.58 1009 S107 -3591 250.58 1010 S106 -3605 119.58 1011 S105 -3619 250.58 1012 S104 -3633 119.58 1013 S103 -3647 250.58 1014 S102 -3661 119.58
Version 1.0 Page 28 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. PAD No. PIN Name X Y 1015 S101 -3675 250.58 1016 S100 -3689 119.58 1017 S99 -3703 250.58 1018 S98 -3717 119.58 1019 S97 -3731 250.58 1020 S96 -3745 119.58 1021 S95 -3759 250.58 1022 S94 -3773 119.58 1023 S93 -3787 250.58 1024 S92 -3801 119.58 1025 S91 -3815 250.58 1026 S90 -3829 119.58 1027 S89 -3843 250.58 1028 S88 -3857 119.58 1029 S87 -3871 250.58 1030 S86 -3885 119.58 1031 S85 -3899 250.58 1032 S84 -3913 119.58 1033 S83 -3927 250.58 1034 S82 -3941 119.58 1035 S81 -3955 250.58 1036 S80 -3969 119.58 1037 S79 -3983 250.58 1038 S78 -3997 119.58 1039 S77 -4011 250.58 1040 S76 -4025 119.58 1041 S75 -4039 250.58 1042 S74 -4053 119.58 1043 S73 -4067 250.58 1044 S72 -4081 119.58 1045 S71 -4095 250.58 1046 S70 -4109 119.58 1047 S69 -4123 250.58 1048 S68 -4137 119.58 PAD No. PIN Name X Y 1049 S67 -4151 250.58 1050 S66 -4165 119.58 1051 S65 -4179 250.58 1052 S64 -4193 119.58 1053 S63 -4207 250.58 1054 S62 -4221 119.58 1055 S61 -4235 250.58 1056 S60 -4249 119.58 1057 S59 -4263 250.58 1058 S58 -4277 119.58 1059 S57 -4291 250.58 1060 S56 -4305 119.58 1061 S55 -4319 250.58 1062 S54 -4333 119.58 1063 S53 -4347 250.58 1064 S52 -4361 119.58 1065 S51 -4375 250.58 1066 S50 -4389 119.58 1067 S49 -4403 250.58 1068 S48 -4417 119.58 1069 S47 -4431 250.58 1070 S46 -4445 119.58 1071 S45 -4459 250.58 1072 S44 -4473 119.58 1073 S43 -4487 250.58 1074 S42 -4501 119.58 1075 S41 -4515 250.58 1076 S40 -4529 119.58 1077 S39 -4543 250.58 1078 S38 -4557 119.58 1079 S37 -4571 250.58 1080 S36 -4585 119.58 1081 S35 -4599 250.58 1082 S34 -4613 119.58 PAD No. PIN Name X Y 1083 S33 -4627 250.58 1084 S32 -4641 119.58 1085 S31 -4655 250.58 1086 S30 -4669 119.58 1087 S29 -4683 250.58 1088 S28 -4697 119.58 1089 S27 -4711 250.58 1090 S26 -4725 119.58 1091 S25 -4739 250.58 1092 S24 -4753 119.58 1093 S23 -4767 250.58 1094 S22 -4781 119.58 1095 S21 -4795 250.58 1096 S20 -4809 119.58 1097 S19 -4823 250.58 1098 S18 -4837 119.58 1099 S17 -4851 250.58 1100 S16 -4865 119.58 1101 S15 -4879 250.58 1102 S14 -4893 119.58 1103 S13 -4907 250.58 1104 S12 -4921 119.58 1105 S11 -4935 250.58 1106 S10 -4949 119.58 1107 S9 -4963 250.58 1108 S8 -4977 119.58 1109 S7 -4991 250.58 1110 S6 -5005 119.58 1111 S5 -5019 250.58 1112 S4 -5033 119.58 1113 S3 -5047 250.58 1114 S2 -5061 119.58 1115 S1 -5075 250.58 1116 G319 -5131 119.58
Version 1.0 Page 29 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. PAD No. PIN Name X Y 1117 G317 -5145 250.58 1118 G315 -5159 119.58 1119 G313 -5173 250.58 1120 G311 -5187 119.58 1121 G309 -5201 250.58 1122 G307 -5215 119.58 1123 G305 -5229 250.58 1124 G303 -5243 119.58 1125 G301 -5257 250.58 1126 G299 -5271 119.58 1127 G297 -5285 250.58 1128 G295 -5299 119.58 1129 G293 -5313 250.58 1130 G291 -5327 119.58 1131 G289 -5341 250.58 1132 G287 -5355 119.58 1133 G285 -5369 250.58 1134 G283 -5383 119.58 1135 G281 -5397 250.58 1136 G279 -5411 119.58 1137 G277 -5425 250.58 1138 G275 -5439 119.58 1139 G273 -5453 250.58 1140 G271 -5467 119.58 1141 G269 -5481 250.58 1142 G267 -5495 119.58 1143 G265 -5509 250.58 1144 G263 -5523 119.58 1145 G261 -5537 250.58 1146 G259 -5551 119.58 1147 G257 -5565 250.58 1148 G255 -5579 119.58 1149 G253 -5593 250.58 1150 G251 -5607 119.58 PAD No. PIN Name X Y 1151 G249 -5621 250.58 1152 G247 -5635 119.58 1153 G245 -5649 250.58 1154 G243 -5663 119.58 1155 G241 -5677 250.58 1156 G239 -5691 119.58 1157 G237 -5705 250.58 1158 G235 -5719 119.58 1159 G233 -5733 250.58 1160 G231 -5747 119.58 1161 G229 -5761 250.58 1162 G227 -5775 119.58 1163 G225 -5789 250.58 1164 G223 -5803 119.58 1165 G221 -5817 250.58 1166 G219 -5831 119.58 1167 G217 -5845 250.58 1168 G215 -5859 119.58 1169 G213 -5873 250.58 1170 G211 -5887 119.58 1171 G209 -5901 250.58 1172 G207 -5915 119.58 1173 G205 -5929 250.58 1174 G203 -5943 119.58 1175 G201 -5957 250.58 1176 G199 -5971 119.58 1177 G197 -5985 250.58 1178 G195 -5999 119.58 1179 G193 -6013 250.58 1180 G191 -6027 119.58 1181 G189 -6041 250.58 1182 G187 -6055 119.58 1183 G185 -6069 250.58 1184 G183 -6083 119.58 PAD No. PIN Name X Y 1185 G181 -6097 250.58 1186 G179 -6111 119.58 1187 G177 -6125 250.58 1188 G175 -6139 119.58 1189 G173 -6153 250.58 1190 G171 -6167 119.58 1191 G169 -6181 250.58 1192 G167 -6195 119.58 1193 G165 -6209 250.58 1194 G163 -6223 119.58 1195 G161 -6237 250.58 1196 G159 -6251 119.58 1197 G157 -6265 250.58 1198 G155 -6279 119.58 1199 G153 -6293 250.58 1200 G151 -6307 119.58 1201 G149 -6321 250.58 1202 G147 -6335 119.58 1203 G145 -6349 250.58 1204 G143 -6363 119.58 1205 G141 -6377 250.58 1206 G139 -6391 119.58 1207 G137 -6405 250.58 1208 G135 -6419 119.58 1209 G133 -6433 250.58 1210 G131 -6447 119.58 1211 G129 -6461 250.58 1212 G127 -6475 119.58 1213 G125 -6489 250.58 1214 G123 -6503 119.58 1215 G121 -6517 250.58 1216 G119 -6531 119.58 1217 G117 -6545 250.58 1218 G115 -6559 119.58
Version 1.0 Page 30 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. PAD No. PIN Name X Y 1219 G113 -6573 250.58 1220 G111 -6587 119.58 1221 G109 -6601 250.58 1222 G107 -6615 119.58 1223 G105 -6629 250.58 1224 G103 -6643 119.58 1225 G101 -6657 250.58 1226 G99 -6671 119.58 1227 G97 -6685 250.58 1228 G95 -6699 119.58 1229 G93 -6713 250.58 1230 G91 -6727 119.58 1231 G89 -6741 250.58 1232 G87 -6755 119.58 1233 G85 -6769 250.58 1234 G83 -6783 119.58 1235 G81 -6797 250.58 1236 G79 -6811 119.58 1237 G77 -6825 250.58 1238 G75 -6839 119.58 1239 G73 -6853 250.58 PAD No. PIN Name X Y 1240 G71 -6867 119.58 1241 G69 -6881 250.58 1242 G67 -6895 119.58 1243 G65 -6909 250.58 1244 G63 -6923 119.58 1245 G61 -6937 250.58 1246 G59 -6951 119.58 1247 G57 -6965 250.58 1248 G55 -6979 119.58 1249 G53 -6993 250.58 1250 G51 -7007 119.58 1251 G49 -7021 250.58 1252 G47 -7035 119.58 1253 G45 -7049 250.58 1254 G43 -7063 119.58 1255 G41 -7077 250.58 1256 G39 -7091 119.58 1257 G37 -7105 250.58 1258 G35 -7119 119.58 1259 G33 -7133 250.58 1260 G31 -7147 119.58 PAD No. PIN Name X Y 1261 G29 -7161 250.58 1262 G27 -7175 119.58 1263 G25 -7189 250.58 1264 G23 -7203 119.58 1265 G21 -7217 250.58 1266 G19 -7231 119.58 1267 G17 -7245 250.58 1268 G15 -7259 119.58 1269 G13 -7273 250.58 1270 G11 -7287 119.58 1271 G9 -7301 250.58 1272 G7 -7315 119.58 1273 G5 -7329 250.58 1274 G3 -7343 119.58 1275 G1 -7357 250.58 1276 DUMMY -7371 119.58 1277 DUMMY -7385 250.58 1278 DUMMY -7399 119.58 A1 -7480 251.58 A2 7480 255.58
Version 1.0 Page 31 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
5 BLOCK DIAGRAM
Version 1.0 Page 32 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
6 PIN DESCRIPTION
6.1 Power Supply Pins
Name I/O Description Connect Pin VDD I Power Supply for Analog, Digital System and B ooster Circuit. VDD VDDI I Power Supply for I/O System. VDDI VDDI_LED I Power Supply for LED driver. If not used, please fix this pad to GND level. AGND I System Ground for Analog System and Booster Circuit. GND DGND I System Ground for I/O System and Digital Sys tem. GND
Version 1.0 Page 33 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
6.2 Interface Logic Pins
Name I/O Description Connect Pin IM3, IM2, IM1, IM0 I -The MCU interface mode select. IM3 IM2 IM1 IM0 MPU Interface Mode Data pin 0 0 0 0 80-8bit parallel I/F DB[7:0] 0 0 0 1 80-16bit parallel I/F DB[15:0] 0 0 1 0 80-9bit parallel I/F DB[8:0] 0 0 1 1 80-18bit parallel I/F DB[17:0], 0 1 0 1 3-line 9bit serial I/F SDA: in/out 2 data lane serial I/F SDA: in/out WRX: in 0 1 1 0 4-line 8bit serial I/F SDA: in/out 1 0 0 0 80-16bit parallel I/F Ⅱ DB[17:10], DB[8:1] 1 0 0 1 80-8bit parallel I/F Ⅱ DB[17:10] 1 0 1 0 80-18bit parallel I/F Ⅱ DB[17:0], 1 0 1 1 80-9bit parallel I/F Ⅱ DB[17:9] 1 1 0 1 3-line 9bit serial I/F Ⅱ SDA: in/ SDO: out 1 1 1 0 4-line 8bit serial I/F Ⅱ SDA:in/ SDO: out DGND/VDDI EXTC I -Select to access extension command (“Low”: system command 1, “High”: system command 1 and 2). -When programming NVM, this pin should connect to high level. DGND/VDDI VPP I -When programming NVM, it needs external power supply voltage (7.5V); the current of Ivpp must be more than 10mA. -If not used, let this pin open. RESX I -This signal will reset the device and it must be applied to properly initialize the chip. -Signal is active low. MCU CSX I -Chip selection pin Low enable. High disable. MCU DCX I -Display data/command selection pin in parallel interface. -This pin is used to be serial interface clock. MCU
Version 1.0 Page 34 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Name I/O Description Connect Pin DCX=’1’: display data or parameter. DCX=’0’: command data. -If not used, please fix this pin at VDDI or DGND. RDX I -Read enable in 8080 MCU parallel interface. -If not used, please fix this pin at VDDI or DGND. MCU WRX I -Write enable in MCU parallel interface. - Display data/command selection pin in 4-line serial interface. - Second Data lane in 2 data lane serial interface. -If not used, please fix this pin at VDDI or DGND. MCU VSYNC I -Vertical (Frame) synchronizing input signal for RGB interface operation. -If not used, please fix to the VDDI or DGND. MCU HSYNC I -Horizontal (Line) synchronizing input signal for RGB interface operation. - If not used, please fix to VDDI or DGND. MCU ENABLE I -Data enable signal for RGB interface operation. -If not used, please fix this pin at VDDI or DGND. MCU DOTCLK I -Dot clock signal for RGB interface operation. -If not used, please fix this pin at VDDI or DGND. MCU SDA I/O -When IM3: Low, SPI interface input/output pin. -When IM3: High, SPI interface input pin. -The data is latched on the rising edge of the SCL signal. -If not used, please fix this pin at VDDI or DGND level. MCU SDO O -SPI interface output pin. -The data is output on the falling edge of the SCL signal. -If not used, let this pin open. MCU DB[17:0] I/O -DB[17:0] are used as MCU parallel interface data bus. 8-bit I/F: when IM3:0, DB[7:0] are used; when IM3:1, DB[17:10] are used. 9-bit I/F: when IM3:0, DB[8:0] are used; when IM3:1, DB[17:9] are used. 16-bit I/F: when IM3:0, DB[15:0] are used; when IM3:1, DB[17:10] and DB[8:1] are used. 18-bit I/F: DB[17:0] are used. -DB[17:0] are used as RGB interface data bus. 6-bit RGB I/F: DB[5:0] are used. 16-bit RGB I/F: DB[17:13], DB[11:1] are used. 18-bit RGB I/F: DB[17:0] are used. -If not used, please fix this pin at VDDI or DGND. MCU TE O -Tearing effect signal is used to synchronize MCU to frame memory MCU
Version 1.0 Page 35 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Name I/O Description Connect Pin writing. -If not used, please let this pin open Note1. “1” = VDDI level, “0” = DGND level. Note2. When in parallel mode, unused data pins must be connected to “1” or “0”. Note3. When CSX=”1”, there is no influence to the parallel and serial interface.
Version 1.0 Page 36 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
6.3 Driver Output Pins
Name I/O Description Connect pin S1 to S720 O -Source driver output pad. LCD G1 to G320 O -Gate driver output pad. VGH: Selecting Gate Lines Level. VGL: Non-selecting Gate Lines Level. LCD AVDD O -Power pad for analog circuit. OPEN VAP(GVDD) O - A power output of grayscale voltage generator. OPEN AVCL O - A power supply pin for generating VAN. OPEN VAN(GVCL) O - A power output (Negative) of grayscale voltage generator. OPEN VGH O - Power output pin for gate driver OPEN VGL O - Power output (Negative) pin for gate driver OPEN VCC O - Monitoring pin of internal digital reference voltage. OPEN VCOM O - A power supply for the TFT-LCD common elec trode. GND LED_PWM O -Output pad for PWM output signal to driving LED. -If not used, keep it open. LED_EN O -Output pad for enabling LED. -If not used, keep it open.
6.4 Test and other pins
TEST3~TEST0 I Input pins for testing. Please open these pins. OPEN TE2 O Output pin for testing. Please keep this pin floating. OPEN TESTO6~TESTO1 O Output pins for testing. Please keep these pins floating. OPEN DUMMY - These pins are dummy (no electrical characteristic) Can pass signal through these pads on TFT panel. Please open these pins. OPEN DUMMYR1 DUMMYR2 These pins are dummy (no electrical characteristic). DUMMYR1 and DUMMYR2 are connected each other internally. OPEN VAG VDDS VDDGX V20 O Used for monitoring Please keep these pins floating. OPEN
Version 1.0 Page 37 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
7 DRIVER ELECTRICAL CHARACTERISTICS
7.1 Absolute Operation Range
Supply Voltage VDD - 0.3 ~ +4.6 V Supply Voltage (Logic) VDDI - 0.3 ~ +4.6 V Driver Supply Voltage VGH-VGL -0.3 ~ +30.0 V Logic Input Voltage Range VIN -0.3 ~ VDDI + 0.5 V Logic Output Voltage Range VO -0.3 ~ VDDI + 0.5 V Operating Temperature Range TOPR -30 ~ +85 ℃ Storage Temperature Range TSTG -40 ~ +125 ℃ Table 1 Absolute Operation Range Note: If one of the above items is exceeded its maximum limitation momentarily, the quality of the product may be degraded. Absolute maximum limitation, therefore, specify the values exceeding which the product may be physically damaged. Be sure to use the product within the recommend range.
Version 1.0 Page 38 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
7.2 DC Characteristics
Parameter Symbol Condition Specification Unit Related Pins MIN. TYP . MAX. Power & Operation Voltage System Voltage VDD Operating voltage 2.4 2.75 3.3 V Interface Operation Voltage VDDI I/O Supply Voltage 1.65 1.8 3.3 V Gate Driver High Voltage VGH 12.2 14.97 V Note 4 Gate Driver Low Voltage VGL -12.5 -7.16 V Gate Driver Supply Voltage | VGH-VGL | 19.36 27.47 V Note 5 Input / Output Logic-High Input Voltage VIH 0.7VDDI VDDI V Note 1 Logic-Low Input Voltage VIL VSS 0.3VDDI V Note 1 Logic-High Output Voltage VOH IOH = -1.0mA 0.8VDDI VDDI V Note 1 Logic-Low Output Voltage VOL IOL = +1.0mA VSS 0.2VDDI V Note 1 Logic-High Input Current IIH VIN = VDDI 1 uA Note 1 Logic-Low Input Current IIL VIN = VSS -1 uA Note 1 Input Leakage Current IIL IOH = -1.0mA -0.1 +0.1 uA Note 1 VCOM Voltage VCOM amplitude VCOM VSS V Source Driver Source Output Range Vsout VAN VAP V Gamma Reference Voltage(Positive) VAP 4.45 6.4 V Note 6 Gamma Reference Voltage(Negative) VAN -4.6 -2.65 V Source Output Settling Time Tr Below with 99% precision 20 us Note 2 Output Offset Voltage VOFFSET 35 mV Note 3 Table 2 Basic DC Characteristics Notes: 1. TA= -30 to 70 (to +85 no damage). ℃ ℃ 2. Source channel loading= 2K Ω+12pF/channel, Gate channel loading=5K Ω+40pF/channel. 3. The Max. value is between measured point of source output and gamma setting value. 4. When evaluating the maximum and minimum of VGH, VDD=2.8V.
Version 1.0 Page 39 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 5. The maximum value of |VGH-VGL| can no over 30V. 6. Default register setting of Vcom and Vcomoffset is 20h
Version 1.0 Page 40 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
7.3 Power Consumption
Ta=25 ℃, Frame rate = 60Hz, Registers setting are IC default setting. Operation Mode Image Current Consumption Typical Maximum IDDI (mA) IDD (mA) IDDI (mA) IDD (mA) Normal Mode Black 0.005 6.0 0.01 7.5 Partial + Idle Mode (48 lines) Black 0.005 5.0 0.01 6.0 Sleep-in Mode N/A 0.005 0.015 0.01 0.03 Table 3 Power Consumption Notes: 1. The Current Consumption is DC characteristics of ST7789V2.
Version 1.0 Page 41 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
7.4 AC Characteristics
7.4.1 8080 Series MCU Parallel Interface Characteristics: 18/16/9/8-bit Bus Figure 1 Parallel Interface Timing Characteristics (8080-Series MCU Interface) VDDI=1.65 to 3.3V, VDD=2.4 to 3.3V, AGND=DGND=0V, Ta=25 ℃ Signal Symbol Parameter Min Max Unit Description D/CX TAST Address setup time 0 ns TAHT Address hold time (Write/Read) 10 ns CSX TCHW Chip select “H” pulse width 0 ns TCS Chip select setup time (Write) 15 ns TRCS Chip select setup time (Read ID) 45 ns TRCSFM Chip select setup time (Read FM) 355 ns TCSF Chip select wait time (Write/Read) 10 ns TCSH Chip select hold time 10 ns WRX TWC Write cycle 66 ns TWRH Control pulse “H” duration 15 ns TWRL Control pulse “L” duration 15 ns RDX (ID) TRC Read cycle (ID) 160 ns When read ID data TRDH Control pulse “H” duration (ID) 90 ns TRDL Control pulse “L” duration (ID) 45 ns RDX (FM) T RCFM Read cycle (FM) 450 ns When read from frame memory TRDHFM Control pulse “H” duration (FM) 90 ns TRDLFM Control pulse “L” duration (FM) 355 ns D[17:0] T DST Data setup time 10 ns For CL=30pF
Version 1.0 Page 43 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
7.4.2 Serial Interface Characteristics (3-line serial):
Figure 4 3-line serial Interface Timing Characteristics VDDI=1.65 to 3.3V, VDD=2.4 to 3.3V, AGND=DGND=0V, Ta=25 ℃ Signal Symbol Parameter Min Max Unit Description CSX TCSS Chip select setup time (write) 15 ns TCSH Chip select hold time (write) 15 ns TCSS Chip select setup time (read) 60 ns TSCC Chip select hold time (read) 65 ns TCHW Chip select “H” pulse width 40 ns SCL TSCYCW Serial clock cycle (Write) 16 ns TSHW SCL “H” pulse width (Write) 7 ns TSLW SCL “L” pulse width (Write) 7 ns TSCYCR Serial clock cycle (Read) 150 ns TSHR SCL “H” pulse width (Read) 60 ns TSLR SCL “L” pulse width (Read) 60 ns SDA (DIN) TSDS Data setup time 7 ns TSDH Data hold time 7 ns DOUT TACC Access time 10 50 ns For maximum CL=30pF For minimum CL=8pF TOH Output disable time 15 50 ns Table 5 3-line serial Interface Characteristics Note : The rising time and falling time (Tr, Tf) of input signal are specified at 15 ns or less. Logic high and low levels are specified as 30% and 70% of VDDI for Input signals.
Version 1.0 Page 44 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
7.4.3 Serial Interface Characteristics (4-line serial):
Figure 5 4-line serial Interface Timing Characteristics VDDI=1.65 to 3.3V, VDD=2.4 to 3.3V, AGND=DGND=0V, Ta=25 ℃ Signal Symbol Parameter MIN MAX Unit Description CSX TCSS Chip select setup time (write) 15 ns TCSH Chip select hold time (write) 15 ns TCSS Chip select setup time (read) 60 ns TSCC Chip select hold time (read) 65 ns TCHW Chip select “H” pulse width 40 ns SCL TSCYCW Serial clock cycle (Write) 16 ns -write command & data ram TSHW SCL “H” pulse width (Write) 7 ns TSLW SCL “L” pulse width (Write) 7 ns TSCYCR Serial clock cycle (Read) 150 ns -read command & data ram TSHR SCL “H” pulse width (Read) 60 ns TSLR SCL “L” pulse width (Read) 60 ns D/CX TDCS D/CX setup time 10 ns TDCH D/CX hold time 10 ns SDA (DIN) TSDS Data setup time 7 ns TSDH Data hold time 7 ns DOUT TACC Access time 10 50 ns For maximum CL=30pF For minimum CL=8pF TOH Output disable time 15 50 ns Table 6 4-line serial Interface Characteristics Note : The rising time and falling time (Tr, Tf) of input signal are specified at 15 ns or less. Logic high and low levels are specified as
Version 1.0 Page 45 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 30% and 70% of VDDI for Input signals.
Version 1.0 Page 46 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
7.4.4 RGB Interface Characteristics:
Figure 6 RGB Interface Timing Characteristics VDDI=1.65 to 3.3V, VDD=2.4 to 3.3V, AGND=DGND=0V, Ta=25 ℃ Signal Symbol Parameter MIN MAX Unit Description HSYNC, VSYNC TSYNCS VSYNC, HSYNC Setup Time 30 - ns ENABLE TENS Enable Setup Time 25 - ns TENH Enable Hold Time 25 - ns DOTCLK PWDH DOTCLK High-level Pulse Width 60 - ns PWDL DOTCLK Low-level Pulse Width 60 - ns TCYCD DOTCLK Cycle Time 120 - ns Trghr, Trghf DOTCLK Rise/Fall time - 20 ns DB TPDS PD Data Setup Time 50 - ns TPDH PD Data Hold Time 50 - ns Table 7 18/16 Bits RGB Interface Timing Characteristics Signal Symbol Parameter MIN MAX Unit Description HSYNC, VSYNC TSYNCS VSYNC, HSYNC Setup Time 35 - ns ENABLE TENS Enable Setup Time 35 - ns HSYNC VSYNC DOTCLK Data Bus Write V IH V IL T SYNCS ENABLE V IH V IL T ENS T ENH V IH V IL V IH V IH V IL V IH V IL Write Data V IH V IL PWDL PWDH T CYCD T PDS T PDH T rgbf T rgbr T rgbf T rgbr
Version 1.0 Page 47 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. TENH Enable Hold Time 35 - ns DOTCLK PWDH DOTCLK High-level Pulse Width 35 - ns PWDL DOTCLK Low-level Pulse Width 35 - ns TCYCD DOTCLK Cycle Time 80 - ns Trghr, Trghf DOTCLK Rise/Fall time - 10 ns DB TPDS PD Data Setup Time 35 - ns TPDH PD Data Hold Time 35 - ns Table 8 6 Bits RGB Interface Timing Characteristics
Version 1.0 Page 48 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
7.4.5 Reset Timing:
During reset Initial condition (Default for H/W reset) RESX Normal operation Shorter than 5us Figure 7 Reset Timing VDDI=1.65 to 3.3V, VDD=2.4 to 3.3V, AGND=DGND=0V, Ta=25 ℃ Related Pins Symbol Parameter MIN MAX Unit RESX TRW Reset pulse duration 10 - us TRT Reset cancel - 5 (Note 1, 5) ms 120 (Note 1, 6, 7) ms Table 9 Reset Timing Notes: 1. The reset cancel includes also required time for loading ID bytes, VCOM setting and other settings from NVM (or similar device) to registers. This loading is done every time when there is HW reset cancel time (tRT) within 5 ms after a rising edge of RESX. 2. Spike due to an electrostatic discharge on RESX line does not cause irregular system reset according to the table below: RESX Pulse Action Shorter than 5us Reset Rejected Longer than 9us Reset Between 5us and 9us Reset starts 3. During the Resetting period, the display will be blanked (The display is entering blanking sequence, which maximum time is 120 ms, when Reset Starts in Sleep Out –mode. The display remains the blank state in Sleep In –mode.) and then return to Default condition for Hardware Reset. 4. Spike Rejection also applies during a valid reset pulse as shown below:
Version 1.0 Page 49 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 5. When Reset applied during Sleep In Mode. 6. When Reset applied during Sleep Out Mode. 7. It is necessary to wait 5msec after releasing RESX before sending commands. Also Sleep Out command cannot be sent for 120msec.
Version 1.0 Page 50 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8 FUNCTION DESCRIPTION
8.1 MPU Interface Type Selection
ST7789V2 supports 8/16/9/18 bit parallel data bus for 8080 series CPU, RGB serial interfaces. Selection of these interfaces are set by IM[3:0] pins as shown below. IM3 IM2 IM1 IM0 Interface Read Back Data Bus Selection 0 0 0 0 80-8bit parallel I/F DB[7:0] 0 0 0 1 80-16bit parallel I/F DB[15:0] 0 0 1 0 80-9bit parallel I/F DB[8:0] 0 0 1 1 80-18bit parallel I/F DB[17:0], 0 1 0 1 3-line 9bit serial I/F SDA: in/out 2 data lane serial I/F SDA: in/out, WRX: in 0 1 1 0 4-line 8bit serial I/F SDA: in/out 1 0 0 0 80-16bit parallel I/F Ⅱ DB[17:10], DB[8:1] 1 0 0 1 80-8bit parallel I/F Ⅱ DB[17:10] 1 0 1 0 80-18bit parallel I/F Ⅱ DB[17:0], 1 0 1 1 80-9bit parallel I/F Ⅱ DB[17:9] 1 1 0 1 3-line 9bit serial I/F Ⅱ SDA: in/ SDO: out 1 1 1 0 4-line 8bit serial I/F Ⅱ SDA: in/ SDO: out Table 10 Interface Type Selection
Version 1.0 Page 51 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.2 8080- Series MCU Parallel InterfaceⅠⅠ ⅠⅠ The MCU can use one of following interfaces: 11-lines with 8-data parallel interface, 12-lines with 9-data parallel interface, 19-line with 16-data parallel interface or 21-lines with 18-data parallel interface. The chip-select CSX (active low) enables/disables the parallel interface. RESX (active low) is an external reset signal. WRX is the parallel data write enable, RDX is the parallel data read enable and D[17:0] is parallel data bus. The LCD driver reads the data at the rising edge of WRX signal. The D/CX is the data/command flag. When D/CX=’1’, D[17:0] bits is either display data or command parameter. When D/C=’0’, D[17:0] bits is command. The interface functions of 8080-series parallel interface are given in following table. IM3 IM2 IM1 IM0 Interface D/CX RDX WRX Read back selection 0 0 0 0 8-bit parallel 0 1 ↑ Write 8-bit command (D7 to D0) 1 1 ↑ Write 8-bit display data or 8-bit parameter (D7 to D0) 1 ↑ 1 Read 8-bit display data (D7 to D0) 1 ↑ 1 Read 8-bit parameter or status (D7 to D0) 0 0 0 1 16-bit parallel 0 1 ↑ Write 8-bit command (D7 to D0) 1 1 ↑ Write 16-bit display data or 8-bit parameter (D15 to D0) 1 ↑ 1 Read 16-bit display data (D15 to D0) 1 ↑ 1 Read 8-bit parameter or status (D7 to D0) 0 0 1 0 9-bit parallel 0 1 ↑ Write 8-bit command (D7 to D0) 1 1 ↑ Write 9-bit display data or 8-bit parameter (D8 to D0) 1 ↑ 1 Read 9-bit display data (D8 to D0) 1 ↑ 1 Read 8-bit parameter or status (D7 to D0) 0 0 1 1 18-bit parallel 0 1 ↑ Write 8-bit command (D7 to D0) 1 1 ↑ Write 18-bit display data or 8-bit parameter (D17 to D0) 1 ↑ 1 Read 18-bit display data (D17 to D0) 1 ↑ 1 Read 8-bit parameter or status (D7 to D0) Table 11 the function of 8080-series parallel interface
8.2.1 Write cycle sequence
The write cycle means that the host writes information (command / data) to the display via the interface. Each write cycle (WRX high-low-high sequence) consists of 3 control signals (DCX, RDX, WRX) and data signals (DB[17:0]). DCX bit is a control signal, which tells if the data is a command or a data. The data signals are the command if the control signal is low (=’0’) and vice versa it is data (=’1’).
Version 1.0 Page 52 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Figure 8 8080-Series WRX Protocol Note: WRX is an unsynchronized signal (It can be stopped). Figure 9 8080-Series Parallel Bus Protocol, Write to Register or Display RAM
8.2.2 Read cycle sequence
The read cycle (RDX high-low-high sequence) means that the host reads information from LCD driver via interface. The driver sends data (D[17:0]) to the host when there is a falling edge of RDX and the host reads data when there is a rising edge of RDX.
Version 1.0 Page 54 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.3 8080- series MCU Parallel InterfaceⅡⅡ ⅡⅡ The MCU uses one of following interface: 11-lines with 8-data parallel interface, 12-lines with 9-data parallel interface, 19-lines with 16-data parallel interface, or 21-lines with 18-data parallel interface. The chip-select CSX(active low) enables and disables the parallel interface. RESX (active low) is an external reset signal. The R/WX is the Read/Write flag and D[17:0] is parallel data bus. The LCD driver reads the data at the rising edge of WRX signal. The D/CX is the data/command flag. When D/CX=’1’, D[17:0] bits is either display data or command parameter. When D/C=’0’, D[17:0] bits is command. The 8080- series biⅡ -directional interface can be used for communication between the micro controller and LCD driver. Interface bus width can be selected with IM3, IM2, IM1 and IM0.The interface functions of 8080- series parallel interfaceⅡ are given in Table 12 The function of 8080-Ⅱ series parallel interface IM3 IM2 IM1 IM0 Interface D/CX RDX WRX Function 1 0 0 0 16-bit Parallel 0 1 ↑ Write 8-bit command (D[8:1]) 1 1 ↑ Write 16-bit display data or 8-bit parameter (D[17:10], D[8:1]) 1 ↑ 1 Read 16-bit Display data (D[17:10], D[8:1]) 1 ↑ 1 Read 8-bit parameter or status (D[8:1]) 1 0 0 1 8-bit Parallel 0 1 ↑ Write 8-bit command (D[17:10]) 1 1 ↑ Write 8-bit display data or 8-bit parameter (D[17:10]) 1 ↑ 1 Read 8-bit Display data (D[17:10]) 1 ↑ 1 Read 8-bit parameter or status (D[17:10]) 1 0 1 0 18-bit Parallel 0 1 ↑ Write 8-bit command (D[8:1]) 1 1 ↑ Write 18-bit display data or 8-bit parameter (D[17:0], D[8:1]) 1 ↑ 1 Read 18-bit Display data (D[17:0]) 1 ↑ 1 Read 8-bit parameter or status (D[8:1]) 1 0 1 1 9-bit Parallel 0 1 ↑ Write 8-bit command (D[17:10]) 1 1 ↑ Write 9-bit display data or 8-bit parameter (D[17:9]) 1 ↑ 1 Read 9-bit Display data (D[17:9]) 1 ↑ 1 Read 8-bit parameter or status (D[17:10]) Table 12 The function of 8080- series parallel interfaceⅡⅡ ⅡⅡ
Version 1.0 Page 55 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.4 Serial Interface
IM3 IM2 IM1 IM0 Interface Read back selection 0 1 0 1 3-line serial interface Ⅰ Via the read instruction (8-bit, 24-bit and 32-bit read parameter) 0 1 1 0 4-line serial interface Ⅰ 1 1 0 1 3-line serial interface Ⅱ 1 1 1 0 4-line serial interface Ⅱ Table 13 Selection of serial interface The serial interface is either 3-lines/9-bits or 4-lines/8-bits bi-directional interface for communication between the micro controller and the LCD driver. The 3-lines serial interface use: CSX (chip enable), SCL (serial clock) and SDA (serial data input/output), and the 4-lines serial interface use: CSX (chip enable), D/CX (data/ command flag), SCL (serial clock) and SDA (serial data input/output). Serial clock (SCL) is used for interface with MCU only, so it can be stopped when no communication is necessary.
8.4.1 Pin description
3-line serial interface Ⅰ Pin Name Description CSX Chip selection signal DCX Clock signal SDA Serial input/output data 4-line serial interface Ⅰ Pin Name Description CSX Chip selection signal WRX Data is regarded as a command when WRX is low Data is regarded as a parameter or data when WRX is high DCX Clock signal SDA Serial input/output data 3-line serial interface Ⅱ Pin Name Description CSX Chip selection signal DCX Clock signal SDA Serial input data SDO Serial output data 4-line serial interface Ⅱ Pin Name Description CSX Chip selection signal WRX Data is regarded as a command when WRX is low Data is regarded as a parameter or data when WRX is high
Version 1.0 Page 56 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. DCX Clock signal SDA Serial input data SDO Serial output data Table 14 pin description of serial interface
8.4.2 Command write mode
The write mode of the interface means the micro controller writes commands and data to the LCD driver. 3-lines serial data packet contains a control bit D/CX and a transmission byte. In 4-lines serial interface, data packet contains just transmission byte and control bit D/CX is transferred by the D/CX pin. If D/CX is “low”, the transmission byte is interpreted as a command byte. If D/CX is “high”, the transmission byte is stored in the display data RAM (memory write command), or command register as parameter. Any instruction can be sent in any order to the driver. The MSB is transmitted first. The serial interface is initialized when CSX is high. In this state, SCL clock pulse or SDA data have no effect. A falling edge on CSX enables the serial interface and indicates the start of data transmission. Figure 12 Serial interface data stream format When CSX is “high”, SCL clock is ignored. During the high period of CSX the serial interface is initialized. At the falling edge of CSX, SCL can be high or low. SDA is sampled at the rising edge of SCL. D/CX indicates whether the byte is command (D/CX=’0’) or parameter/RAM data (D/CX=’1’). D/CX is sampled when first rising edge of SCL (3-line serial interface) or 8th rising edge of SCL (4-line serial interface). If CSX stays low after the last bit of command/data byte, the serial interface expects the D/CX bit (3-line serial interface) or D7
Version 1.0 Page 58 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.4.3 Read function
The read mode of the interface means that the micro controller reads register value from the driver. To achieve read function, the micro controller first has to send a command (read ID or register command) and then the following byte is transmitted in the opposite direction. After that CSX is required to go to high before a new command is send (see the below figure). The driver samples the SDA (input data) at rising edge of SCL, but shifts SDA (output data) at the falling edge of SCL. Thus the micro controller is supported to read at the rising edge of SCL. After the read status command has been sent, the SDA line must be set to tri-state no later than at the falling edge of SCL of the last bit. 8.4.4 3-line serial interface / ⅠⅠ ⅠⅠ ⅡⅡ ⅡⅡ protocol 3-line serial protocol (for RDID1/RDID2/RDID3/0Ah/0Bh/0Ch/0Dh/0Eh/0Fh command: 8-bit read):
Version 1.0 Page 59 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 3-line serial protocol (for RDDID command: 24-bit read) 3-line Serial Protocol (for RDDST command: 32-bit read) Figure 15 3-line serial interface read protocol
Version 1.0 Page 60 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.4.5 4-line serial protocol 4-line serial protocol (for RDID1/RDID2/RDID3/0Ah/0Bh/0Ch/0Dh/0Eh/0Fh command: 8-bit read): D7 D6 D5 D4 D3 D2 D1 D0 S TB TB CSX SCL SDO D7 D6 D5 D4 D3 D2 D1 D0 P S SDA Hi”Z Hi”Z D/CX D7 D6 D5 D4 D3 D2 D1 D0 D7SDA D7 D6 D5 D4 D3 D2 D1 D0 Interface”І Interface”□ 4-line serial protocol (for RDDID command: 24-bit read) 4-line Serial Protocol (for RDDST command: 32-bit read)
Version 1.0 Page 61 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Figure 16 4-line serial interface read protocol
Version 1.0 Page 62 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.4.6 2 data lane serial Interface Interface selection: IM3 IM2 IM1 IM0 Interface Read back selection 0 1 0 1 2 data lane serial interface Via the read instruction (8-bit, 24-bit and 32-bit read) Table 15 IM pin selection 2-wire data lane serial interface use: CSX (chip enable), DCX (serial clock) and SDA (serial data input/output 1), and WRX (serial data input 2). To enter this interface, command E7h need set 10h. 2 data lane hardware suggestion and Pin description: 2 data lane serial interface, IM[3:0]=0101 Figure 17 Hardware suggestion of 2 data lane serial interface Pin Name Description CSX Chip selection signal DCX Clock signal SDA Serial data input/output1 WRX Serial data input2 Table 16 Pin description of 2 data lane serial interface
Version 1.0 Page 63 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Command write mode: The command write protocol of 2-wire data lane serial interface is the same with the 3-line serial interface, so users can ignore the input data of WRX. Any instruction can be sent in any order to the driver. The MSB is transmitted first. The serial interface is initialized when CSX is high. In this state, SCL clock pulse or SDA data have no effect. A falling edge on CSX enables the serial interface and indicates the start of data transmission. Figure 18 3-line serial interface write protocol (write to register with control bit in transmission) SRAM write mode: The SRAM write mode of 2-wire data line serial interface need use SDA pin and WRX pin to be data input pins. Read function: The read mode of 2-wire data lane serial interface is the same with the 3-line serial interface and WRX pin can be ignored. To achieve read function, the micro controller first has to send a command (read ID or register command) and then the following byte is transmitted in the opposite direction. After that CSX is required to go to high before a new command is send (see the below figure). The driver samples the SDA (input data) at rising edge of SCL, but shifts SDA (output data) at the falling edge of SCL. Thus the micro controller is supported to read at the rising edge of SCL. After the read status command has been sent, the SDA line must be set to tri-state no later than at the falling edge of SCL of the last bit. 3-line serial interface ⅠⅠ ⅠⅠ/ⅡⅡ ⅡⅡ protocol: 3-line serial protocol (for RDID1/RDID2/RDID3/0Ah/0Bh/0Ch/0Dh/0Eh/0Fh command: 8-bit read):
Version 1.0 Page 64 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 3-line serial protocol (for RDDID command: 24-bit read) 3-line Serial Protocol (for RDDST command: 32-bit read)
Version 1.0 Page 65 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Figure 19 3-line serial interface read protocol
Version 1.0 Page 66 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.5 Data Transfer Break and Recovery
If there is a break in data transmission by RESX pulse, while transferring a command or frame memory data or multiple parameter command data, before Bit D0 of the byte has been completed, then driver will reject the previous bits and have reset the interface such that it will be ready to receive command data again when the chip select line (CSX) is next activated after RESX have been HIGH state. If there is a break in data transmission by CSX pulse, while transferring a command or frame memory data or multiple parameter command data, before Bit D0 of the byte has been completed, then driver will reject the previous bits and have reset the interface such that it will be ready to receive the same byte re-transmitted when the chip select line (CSX) is next activated. If 1, 2 or more parameter commands are being sent and a break occurs while sending any parameter before the last one and if the host then sends a new command rather than re-transmitting the parameter that was interrupted, then the parameters that were successfully sent are stored and the parameter where the break occurred is rejected. The interface is ready to receive next byte as shown below. Figure 20 Write interrupts recovery (serial interface) If a 2 or more parameter commands are being sent and a break occurs by the other command before the last one is sent, then the parameters that were successfully sent are stored and the other parameter of that command remains previous value.
Version 1.0 Page 67 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Figure 21 Write interrupts recovery (both serial and parallel Interface)
Version 1.0 Page 68 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.6 Data Transfer Pause
It will be possible when transferring a command, frame memory data or multiple parameter data to invoke a pause in the data transmission. If the chip select line is released after a whole byte of a frame memory data or multiple parameter data has been completed, then driver will wait and continue the frame memory data or parameter data transmission from the point where it was paused. If the chip select Line is released after a whole byte of a command has been completed, then the display module will receive either the command‘s parameters (if appropriate) or a new command when the chip select line is next enabled as shown below. This applies to the following 4 conditions: 1) Command-Pause-Command 2) Command-Pause-Parameter 3) Parameter-Pause-Command 4) Parameter-Pause-Parameter
8.6.1 Parallel interface pause
Figure 22 Parallel bus pause protocol (paused by CSX)
8.7 Data Transfer Mode
The module has three kinds color modes for transferring data to the display RAM. These are 12-bit color per pixel, 16-bit color per pixel and 18-bit color per pixel. The data format is described for each interface. Data can be downloaded to the frame memory by 2 methods.
8.7.1 Method 1
The image data is sent to the frame memory in successive frame writes, each time the frame memory is filled, the frame memory pointer is reset to the start point and the next frame is written.
Version 1.0 Page 69 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.7.2 Method 2
The image data is sent and at the end of each frame memory download, a command is sent to stop frame memory write. Then start memory write command is sent, and a new frame is downloaded. Note 1: These apply to all data transfer Color modes on both serial and parallel interfaces. Note 2: The frame memory can contain both odd and even number of pixels for both methods. Only complete pixel data will be stored in the frame memory.
Version 1.0 Page 70 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.8 Data Color Coding
8.8.1 8080- series ⅠⅠ ⅠⅠ 8-bit Parallel Interface The 8080- series 8Ⅰ -bit parallel interface of ST7789V2 can be used by setting IM[3:0]=”0000b”. Different display data formats are available for three Colors depth supported by listed below. - 4k colors, RGB 4,4,4-bit input. - 65k colors, RGB 5,6,5-bit input. - 262k colors, RGB 6,6,6-bit input. 8.8.2 8-bit data bus for 12-bit/pixel (RGB 4-4-4-bit input), 4K-Colors, 3Ah=”03h” R1, Bit 3 B1, Bit 3 G2, Bit 3 R3, Bit 30 R1, Bit 2 B1, Bit 2 G2, Bit 2 R3, Bit 20 R1, Bit 1 B1, Bit 1 G2, Bit 1 R3, Bit 11 R1, Bit 0 B1, Bit 0 G2, Bit 0 R3, Bit 00 G1, Bit 3 R2, Bit 3 B2, Bit 3 G3, Bit 31 G1, Bit 2 R2, Bit 2 B2, Bit 2 G3, Bit 21 G1, Bit 1 R2, Bit 1 B2, Bit 1 G3, Bit 10 G1, Bit 0 R2, Bit 0 B2, Bit 0 G3, Bit 00 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” Pixel n Pixel n+1 Look”up table for 4096 color data mapping (12 bits to 18 bits) 12 bits 12 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 18 bits Frame memory Note 1: The data order is as follows, MSB=D7, LSB=D0 and picture data is MSB=Bit 3, LSB=Bit 0 for Red, Green and Blue data. Note 2: 3-time transfer is used to transmit 2 pixel data with the 12-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 71 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.3 8-bit data bus for 16-bit/pixel (RGB 5-6-5-bit input), 65K-Colors, 3Ah=”05h” There is 1pixel (3 sub-pixels) per 2-byte R1, Bit 4 G1, Bit 20 R1, Bit 3 G1, Bit 10 R1, Bit 2 G1, Bit 01 R1, Bit 1 B1, Bit 40 R1, Bit 0 B1, Bit 31 G1, Bit 5 B1, Bit 21 G1, Bit 4 B1, Bit 10 G1, Bit 3 B1, Bit 00 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” Pixel n Pixel n+1 Look”up table for 65k color data mapping (16 bits to 18 bits) 16 bits 16 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 18 bits Frame memory R2, Bit 4 G2, Bit 2 R2, Bit 3 G2, Bit 1 R2, Bit 2 G2, Bit 0 R2, Bit 1 B2, Bit 4 R2, Bit 0 B2, Bit 3 G2, Bit 5 B2, Bit 2 G2, Bit 4 B2, Bit 1 G2, Bit 3 B2, Bit 0 Note 1: The data order is as follows, MSB=D15, LSB=D0 and picture data is MSB=Bit 5, LSB=Bit 0 for Green, and MSB=Bit 4, LSB=Bit 0 for Red and Blue data. Note 2: 2-times transfer is used to transmit 1 pixel data with the 16-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 72 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.4 8-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h” There is 1pixel (3 sub-pixels) per 3-bytes. R1, Bit 4 R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 R1, Bit 5 ” ”0 ” ”0 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory ” ” ” ” G1, Bit 4 G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 G1, Bit 5 B1, Bit 4 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 B1, Bit 5 R2, Bit 4 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R2, Bit 5 Note 1: The data order is as follows, MSB=D7, LSB=D0 and picture data is MSB=Bit 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 3-times transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 73 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.5 8080- series ⅡⅡ ⅡⅡ 8-bit Parallel Interface The 8080- series 8Ⅱ -bit parallel interface of ST7789V2 can be used by setting IM[3:0]=”1001b”. Different display data formats are available for three Colors depth supported by listed below. - 65k colors, RGB 5,6,5-bit input. - 262k colors, RGB 6,6,6-bit input. 8.8.6 8-bit data bus for 16-bit/pixel (RGB 5-6-5-bit input), 65K-Colors, 3Ah=”05h” Note 1: The data order is as follows, MSB=D17, LSB=D10 and picture data is MSB=Bit 5, LSB=Bit 0 for Green, and MSB=Bit 4, LSB=Bit 0 for Red and Blue data. Note 2: 2-times transfer transmit 1 pixel data with the 16-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 74 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.7 8-bit data bus for 18-bit/pixel (RGB 6-6-6-bit input), 262K-Colors, 3Ah=”06h” R1, Bit 4 R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 R1, Bit 5 n n0 n n0 8080nseries control pins RESX CSX D/CX “1” WRX RDX “1” D17 D16 D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory n n n n G1, Bit 4 G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 G1, Bit 5 B1, Bit 4 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 B1, Bit 5 R2, Bit 4 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R2, Bit 5 Note 1: The data order is as follows, MSB=D17, LSB=D10 and picture data is MSB=Bit 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 3-times transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 75 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.8 8080- series 16ⅠⅠ ⅠⅠ -Bit Parallel Interface The 8080- series 16Ⅰ -bit parallel interface of ST7789V2 can be used by setting IM[3:0]=”0001b”. Different display data formats are available for three colors depth supported by listed below. - 4k colors, RGB 4,4,4-bit input - 65k colors, RGB 5,6,5-bit input - 262k colors, RGB 6,6,6-bit input
Version 1.0 Page 76 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.9 16-bit data bus for 12-bit/pixel (RGB 4-4-4-bit input), 4K-Colors, 3Ah=”03h” There is 1pixel (3 sub-pixels) per 1byte G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 12 bits 12 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 18 bits Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 G2, Bit 3 G2, Bit 2 G2, Bit 1 G2, Bit 0 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 B2, Bit 3 B2, Bit 2 B2, Bit 1 B2, Bit 0 G3, Bit 3 G3, Bit 2 G3, Bit 1 G3, Bit 0 R3, Bit 3 R3, Bit 2 R3, Bit 1 R3, Bit 0 B3, Bit 3 B3, Bit 2 B3, Bit 1 B3, Bit 0 G4, Bit 3 G4, Bit 2 G4, Bit 1 G4, Bit 0 R4, Bit 3 R4, Bit 2 R4, Bit 1 R4, Bit 0 B4, Bit 3 B4, Bit 2 B4, Bit 1 B4, Bit 0 Pixel n+2 Pixel n+3 Look”up table for 4096 color data mapping (12 bits to 18 bits) Note 1: The data order is as follows, MSB=D11, LSB=D0 and picture data is MSB=Bit 3, LSB=Bit 0 for Red, Green and Blue data. Note 2: 1-times transfer (D11 to D0) is used to transmit 1 pixel data with the 12-bit color depth information.
Version 1.0 Page 77 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.10 16-bit data bus for 16-bit/pixel (RGB 5-6-5-bit input) 65K-Color, 3Ah=”05h” There is 1 pixel (3 sub-pixels) per 1 byte Note 1: The data order is as follows, MSB=D15, LSB=D0 and picture data is MSB=Bit 5, LSB=Bit 0 for Green, and MSB=Bit 4, LSB=Bit 0 for Red and Blue data. Note 2: 1-times transfer (D15 to D0) is used to transmit 1 pixel data with the 16-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 78 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.11 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”00b” There are 2 pixels (6 sub-pixels) per 3 bytes 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 B2, Bit 3 B2, Bit 2 B2, Bit 1 B2, Bit 0 B1, Bit 4 B2, Bit 4 R1, Bit 4 G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 G3, Bit 3 G3, Bit 2 G3, Bit 1 G3, Bit 0 G1, Bit 5 G1, Bit 4 G3, Bit 5 G3, Bit 4 R1, Bit 5 ” ” ” ” ” ” ” ” B1, Bit 5 B2, Bit 5 ” ” ” ” ” ” ” ” R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R2, Bit 4 R2, Bit 5 G2, Bit 3 G2, Bit 2 G2, Bit 1 G2, Bit 0 G2, Bit 5 G2, Bit 4 R3, Bit 3 R3, Bit 2 R3, Bit 1 R3, Bit 0 R3, Bit 4 R3, Bit 5 Note 1: The data order is as follows, MSB=D15, LSB=D0 and picture data is MSB=Bits 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 3-times transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 79 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.12 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”01b” 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 G2, Bit 3 G2, Bit 2 G2, Bit 1 G2, Bit 0 B1, Bit 4 G2, Bit 4 R1, Bit 4 G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 G1, Bit 5 G1, Bit 4 R1, Bit 5 ” ” ” ” ” ” ” ” B1, Bit 5 G2, Bit 5 ” ” ” ” ” ” ” ” R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R2, Bit 5 R2, Bit 4 B2, Bit 3 B2, Bit 2 B2, Bit 1 B2, Bit 0 B2, Bit 4 B2, Bit 5 Note 1: The data order is as follows, MSB=D15, LSB=D0 and picture data is MSB=Bits 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 2-times transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 80 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.13 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”10b” 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 G2, Bit 1 G2, Bit 0 B2, Bit 5 B2, Bit 4 B1, Bit 0 G2, Bit 2 R1, Bit 4 G1, Bit 1 G1, Bit 0 B1, Bit 5 B1, Bit 4 G1, Bit 3 G1, Bit 2 R1, Bit 5 G1, Bit 5 ” G2, Bit 5 ” G1, Bit 4 ” G2, Bit 4 ” B1, Bit 1 G2, Bit 3 B1, Bit 3 ” B2, Bit 3 ” B1, Bit 2 ” B2, Bit2 ” R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R2, Bit 5 R2, Bit 4 B2, Bit 0 B2, Bit 1 Note 1: The data order is as follows, MSB=D15, LSB=D0 and picture data is MSB=Bits 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 2-times transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 81 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.14 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”11b” n n n n n n n n 8080nseries control pins RESX CSX D/CX “1” WRX RDX “1” D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory n n n n R1, Bit 1 R1, Bit 0 G1, Bit 5 G1, Bit 4 n n n n R1, Bit 2 n n n n n n B2, Bit 5 B2, Bit 4 B2, Bit 3 B2, Bit 2 n n G2, Bit 1 G2, Bit 0 n n G1, Bit 3 n G2, Bit 3 n G1, Bit 2 n G2, Bit 2 R1, Bit 3 n R1, Bit 5 B1, Bit 1 R2, Bit 5 B2, Bit 1 R1, Bit 4 B1, Bit 0 R2, Bit 4 B2, Bit 0 n n n n n n R2, Bit 1 R2, Bit 0 G2, Bit 5 G2, Bit 4 R2, Bit 2 R2, Bit 3 B1, Bit 5 B1, Bit 4 B1, Bit 3 B1, Bit 2 G1, Bit 0 G1, Bit 1 Note 1: The data order is as follows, MSB=D15, LSB=D0 and picture data is MSB=Bits 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 2-times transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 82 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.15 8080- series 16ⅡⅡ ⅡⅡ -Bit Parallel Interface The 8080- series 16Ⅱ -bit parallel interface of ST7789V2 can be used by setting IM[3:0]=”1000b”. Different display data formats are available for two colors depth supported by listed below. - 65k colors, RGB 5,6,5-bit input - 262k colors, RGB 6,6,6-bit input 8.8.16 16-bit data bus for 16-bit/pixel (RGB 5-6-5-bit input) 65K-Color, 3Ah=”05h” There is 1 pixel (3 sub-pixels) per 1 byte Note 1: The data order is as follows, MSB=D17, LSB=D1 and picture data is MSB=Bit 5, LSB=Bit 0 for Green, and MSB=Bit 4, LSB=Bit 0 for Red and Blue data. Note 2: 1-times transfer (D17~D10, D8~D1) is used to transmit 1 pixel data with the 16-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 83 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.17 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”00b” There are 2 pixels (6 sub-pixels) per 3 bytes 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” D17 D16 D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 B2, Bit 3 B2, Bit 2 B2, Bit 1 B2, Bit 0 B1, Bit 4 B2, Bit 4 R1, Bit 4 G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 G3, Bit 3 G3, Bit 2 G3, Bit 1 G3, Bit 0 G1, Bit 5 G1, Bit 4 G3, Bit 5 G3, Bit 4 R1, Bit 5 ” ” ” ” ” ” ” ” B1, Bit 5 B2, Bit 5 ” ” ” ” ” ” ” ” R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R2, Bit 4 R2, Bit 5 G2, Bit 3 G2, Bit 2 G2, Bit 1 G2, Bit 0 G2, Bit 5 G2, Bit 4 R3, Bit 3 R3, Bit 2 R3, Bit 1 R3, Bit 0 R3, Bit 4 R3, Bit 5 Note 1: The data order is as follows, MSB=D17, LSB=D1 and picture data is MSB=Bits 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 3-times transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 84 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.18 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”01b” 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” D17 D16 D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 G2, Bit 3 G2, Bit 2 G2, Bit 1 G2, Bit 0 B1, Bit 4 G2, Bit 4 R1, Bit 4 G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 G1, Bit 5 G1, Bit 4 R1, Bit 5 ” ” ” ” ” ” ” ” B1, Bit 5 G2, Bit 5 ” ” ” ” ” ” ” ” R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R2, Bit 5 R2, Bit 4 B2, Bit 3 B2, Bit 2 B2, Bit 1 B2, Bit 0 B2, Bit 4 B2, Bit 5 Note 1: The data order is as follows, MSB=D17, LSB=D1 and picture data is MSB=Bits 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 2-times transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’ 8.8.19 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”,
Version 1.0 Page 85 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. MDT[1:0]=”10b” 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” D17 D16 D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 G2, Bit 1 G2, Bit 0 B2, Bit 5 B2, Bit 4 B1, Bit 0 G2, Bit 2 R1, Bit 4 G1, Bit 1 G1, Bit 0 B1, Bit 5 B1, Bit 4 G1, Bit 3 G1, Bit 2 R1, Bit 5 G1, Bit 5 ” G2, Bit 5 ” G1, Bit 4 ” G2, Bit 4 ” B1, Bit 1 G2, Bit 3 B1, Bit 3 ” B2, Bit 3 ” B1, Bit 2 ” B2, Bit2 ” R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R2, Bit 5 R2, Bit 4 B2, Bit 0 B2, Bit 1 Note 1: The data order is as follows, MSB=D17, LSB=D0 and picture data is MSB=Bits 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 2-times transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 86 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.20 16-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”, MDT[1:0]=”11b” 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” D17 D16 D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 1 R1, Bit 0 G1, Bit 5 G1, Bit 4 R1, Bit 2 B2, Bit 5 B2, Bit 4 B2, Bit 3 B2, Bit 2 G2, Bit 1 G2, Bit 0 ” G1, Bit 3 ” G2, Bit 3 ” G1, Bit 2 ” G2, Bit 2 R1, Bit 3 R1, Bit 5 B1, Bit 1 R2, Bit 5 B2, Bit 1 R1, Bit 4 B1, Bit 0 R2, Bit 4 B2, Bit 0 R2, Bit 1 R2, Bit 0 G2, Bit 5 G2, Bit 4 R2, Bit 2 R2, Bit 3 B1, Bit 5 B1, Bit 4 B1, Bit 3 B1, Bit 2 G1, Bit 0 G1, Bit 1 Note 1: The data order is as follows, MSB=D17, LSB=D1 and picture data is MSB=Bits 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 2-times transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 87 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.21 8080- series 9ⅠⅠ ⅠⅠ -Bit Parallel Interface The 8080- series 9Ⅰ -bit parallel interface of ST7789V2 can be used by setting IM[3:0]=”0010b”Different display data formats are available for two colors depth supported by listed below. -65k colors, RGB 5,6,5-bit input -262k colors, RGB 6,6,6-bit input
8.8.22 Write 9-bit data for RGB 5-6-5-bit input (65K-Color), 3Ah=”05h”
Note 1: The data order is as follows, MSB=D7, LSB=D0 and picture data is MSB=Bit 4, LSB=Bit 0 for Red, Green and Blue data. Note 2: 2-time transfer is used to transmit 1 pixel data with the 16-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 88 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.8.23 Write 9-bit data for RGB 6-6-6-bit input (262K-Color), 3Ah=”06h”, MDT[1:0]=”00b”
There is 1 pixel (3 sub-pixels) per 2bytes R1, Bit 40 R1, Bit 30 R1, Bit 21 R1, Bit 10 R1, Bit 01 R1, Bit 5 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory G1, Bit 4 G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 B1, Bit 4 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 B1, Bit 5 R2, Bit 4 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R2, Bit 5” G1, Bit 5 G2, Bit 4 G2, Bit 3 G2, Bit 5 B2, Bit 4 B2, Bit 3 B2, Bit 2 B2, Bit 1 B2, Bit 0 B2, Bit 5 G2, Bit 2 G2, Bit 1 G2, Bit 0 Note 1: The data order is as follows, MSB=D8, LSB=D0 and picture data is MSB=Bit 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 2-time transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 89 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.8.24 Write 9-bit data for RGB 6-6-6-bit input (262K-Color), 3Ah=”06h”, MDT[1:0]=”01b”
R1, Bit 4 R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 R1, Bit 5 ” ”0 ” ”0 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory ” ” ” ” G1, Bit 4 G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 G1, Bit 5 B1, Bit 4 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 B1, Bit 5 R2, Bit 4 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R2, Bit 5 Note 1: The data order is as follows, MSB=D8, LSB=D0 and picture data is MSB=Bit 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 3-time transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 90 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.25 8080- series 9ⅡⅡ ⅡⅡ -bit Parallel Interface The 8080- series 9Ⅱ -bit parallel interface of ST7789V2 can be used by setting IM[3:0]=”1011b”Different display data formats are available for two colors depth supported by listed below. -65k colors, RGB 5,6,5-bit input -262k colors, RGB 6,6,6-bit input
8.8.26 Write 9-bit data for RGB 5-6-5-bit input (65K-Color), 3Ah=”05h”
Note 1: The data order is as follows, MSB=D16, LSB=D9 and picture data is MSB=Bit 4, LSB=Bit 0 for Red, Green and Blue data. Note 2: 2-time transfer is used to transmit 1 pixel data with the 16-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 91 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.8.27 Write 9-bit data for RGB 6-6-6-bit input (262K-Color), 3Ah=”06h”, MDT[1:0]=”00b”
There is 1 pixel (3 sub-pixels) per 2bytes R1, Bit 40 R1, Bit 31 R1, Bit 20 R1, Bit 11 R1, Bit 01 R1, Bit 5 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” D16 D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory G1, Bit 4 G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 B1, Bit 4 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 B1, Bit 5 R2, Bit 4 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R2, Bit 50 G1, Bit 5 D17 G2, Bit 4 G2, Bit 3 G2, Bit 5 B2, Bit 4 B2, Bit 3 B2, Bit 2 B2, Bit 1 B2, Bit 0 B2, Bit 5 G2, Bit 2 G2, Bit 1 G2, Bit 0 Note 1: The data order is as follows, MSB=D17, LSB=D9 and picture data is MSB=Bit 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 2-time transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 92 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.8.28 Write 9-bit data for RGB 6-6-6-bit input (262K-Color), 3Ah=”06h”, MDT[1:0]=”01b”
R1, Bit 4 R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 R1, Bit 5 ” ”0 ” ”” 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” D16 D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory ” ” ” ” G1, Bit 4 G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 G1, Bit 5 B1, Bit 4 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 B1, Bit 5 R2, Bit 4 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R2, Bit 5 0 ” ” ” ”D17 Note 1: The data order is as follows, MSB=D16, LSB=D11 and picture data is MSB=Bit 5, LSB=Bit 0 for Red, Green and Blue data. Note 2: 3-time transfer is used to transmit 1 pixel data with the 18-bit color depth information. Note 3: ‘-‘ = Don’t care – Can be set to ‘0’ or ‘1’
Version 1.0 Page 93 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.29 8080- series 18ⅠⅠ ⅠⅠ -Bit Parallel Interface The 8080- seriⅠ es 18-bit parallel interface of ST7789V2 can be used by setting IM[3:0]=”0011b”. Different display data formats are available for three colors depth supported by listed below. - 4k colors, RGB 4,4,4-bit input - 65k colors, RGB 5,6,5-bit input - 262k colors, RGB 6,6,6-bit input.
Version 1.0 Page 94 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.30 18-bit data bus for 12-bit/pixel (RGB-4-4-4-bit input), 4K-colors, 3Ah=”03h” There is 1 pixel (3 sub-pixels) per byte G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 8080-series control pins RESX CSX D/CX “1” WRX RDX “1” D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 12 bits 12 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 18 bits Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 G2, Bit 3 G2, Bit 2 G2, Bit 1 G2, Bit 0 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 B2, Bit 3 B2, Bit 2 B2, Bit 1 B2, Bit 0 G3, Bit 3 G3, Bit 2 G3, Bit 1 G3, Bit 0 R3, Bit 3 R3, Bit 2 R3, Bit 1 R3, Bit 0 B3, Bit 3 B3, Bit 2 B3, Bit 1 B3, Bit 0 G4, Bit 3 G4, Bit 2 G4, Bit 1 G4, Bit 0 R4, Bit 3 R4, Bit 2 R4, Bit 1 R4, Bit 0 B4, Bit 3 B4, Bit 2 B4, Bit 1 B4, Bit 0 Pixel n+2 Pixel n+3 Look-Up Table for 4096 Color data mapping (12 bits to 18 bits) D17 - -D16 Note 1: The data order is as follows, MSB=D11, LSB=D0 and picture data is MSB=Bit 3, LSB=Bit 0 for Red, Green and Blue data. Note 2: 1-times transfer is used to transmit 1 pixel data with the 12-bit color depth information.
Version 1.0 Page 95 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.31 18-bit data bus for 16-bit/pixel (RGB-5-6-5-bit input), 65K-colors, 3Ah=”05h” There is one pixel (3 sub-pixels) per byte Note 1: The data order is as follows, MSB=D15, LSB=D0 and picture data is MSB=Bit 5, LSB=Bit 0 for Green, and MSB=Bit 4, LSB=Bit 0 for Red and Blue data.
Version 1.0 Page 96 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Note 2: 1-time transfer is used to transmit 1 pixel data with the 16-bit color depth information.
Version 1.0 Page 97 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.32 18-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-colors, 3Ah=”06h” There is 1 pixel (3 sub-pixels) per byte G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 8080-series control pins RESX CSX D/CX “1” WRX RDX “1” D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 G2, Bit 3 G2, Bit 2 G2, Bit 1 G2, Bit 0 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 B2, Bit 3 B2, Bit 2 B2, Bit 1 B2, Bit 0 G3, Bit 3 G3, Bit 2 G3, Bit 1 G3, Bit 0 R3, Bit 3 R3, Bit 2 R3, Bit 1 R3, Bit 0 B3, Bit 3 B3, Bit 2 B3, Bit 1 B3, Bit 0 G4, Bit 3 G4, Bit 2 G4, Bit 1 G4, Bit 0 R4, Bit 3 R4, Bit 2 R4, Bit 1 R4, Bit 0 B4, Bit 3 B4, Bit 2 B4, Bit 1 B4, Bit 0 Pixel n+2 Pixel n+3 D17 D16 R1, Bit 4 R2, Bit 4 R3, Bit 4 R4, Bit 4 G1, Bit 5 G1, Bit 4 G2, Bit 5 G2, Bit 4 G3, Bit 5 G3, Bit 4 G4, Bit 5 G4, Bit 4 B1, Bit 4 B2, Bit 4 B3, Bit 4 B4, Bit 4 R1, Bit 5 R2, Bit 5 R3, Bit 5 R4, Bit 5 B1, Bit 5 B2, Bit 5 B3, Bit 5 B4, Bit 5 Note 1: The data order is as follows, MSB=D17, LSB=D0 and picture data is MSB=Bit 5, LSB=Bit 0 for Read, Green and Blue data. Note 2: 1-times transfer (D17o D0) is used to transmit 1 pixel data with the 18-bit color depth information.
Version 1.0 Page 98 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.33 8080- series 18ⅡⅡ ⅡⅡ -Bit Parallel Interface The 8080- series 18Ⅱ -bit parallel interface of ST7789V2 can be used by setting IM[3:0]=”1010b”. Different display data formats are available for two colors depth supported by listed below. - 65k colors, RGB 5,6,5-bit input - 262k colors, RGB 6,6,6-bit input.
Version 1.0 Page 99 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.34 18-bit data bus for 16-bit/pixel (RGB-5-6-5-bit input), 65K-colors, 3Ah=”05h” There is one pixel (3 sub-pixels) per byte Note 1: The data order is as follows, MSB=D15, LSB=D0 and picture data is MSB=Bit 5, LSB=Bit 0 for Green, and MSB=Bit 4, LSB=Bit 0 for Red and Blue data.
Version 1.0 Page 100 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Note 2: 1-time transfer is used to transmit 1 pixel data with the 16-bit color depth information.
Version 1.0 Page 101 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.35 18-bit data bus for 18-bit/pixel (RGB-6-6-6-bit input), 262K-colors, 3Ah=”06h” There is 1 pixel (3 sub-pixels) per byte G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 8080”series control pins RESX CSX D/CX “1” WRX RDX “1” D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 G2, Bit 3 G2, Bit 2 G2, Bit 1 G2, Bit 0 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 B2, Bit 3 B2, Bit 2 B2, Bit 1 B2, Bit 0 G3, Bit 3 G3, Bit 2 G3, Bit 1 G3, Bit 0 R3, Bit 3 R3, Bit 2 R3, Bit 1 R3, Bit 0 B3, Bit 3 B3, Bit 2 B3, Bit 1 B3, Bit 0 G4, Bit 3 G4, Bit 2 G4, Bit 1 G4, Bit 0 R4, Bit 3 R4, Bit 2 R4, Bit 1 R4, Bit 0 B4, Bit 3 B4, Bit 2 B4, Bit 1 B4, Bit 0 Pixel n+2 Pixel n+3 D17 D16 R1, Bit 4 R2, Bit 4 R3, Bit 4 R4, Bit 4 G1, Bit 5 G1, Bit 4 G2, Bit 5 G2, Bit 4 G3, Bit 5 G3, Bit 4 G4, Bit 5 G4, Bit 4 B1, Bit 4 B2, Bit 4 B3, Bit 4 B4, Bit 4 R1, Bit 5 R2, Bit 5 R3, Bit 5 R4, Bit 5 B1, Bit 5 B2, Bit 5 B3, Bit 5 B4, Bit 5 Note 1: The data order is as follows, MSB=D17, LSB=D0 and picture data is MSB=Bit 5, LSB=Bit 0 for Read, Green and Blue data. Note 2: 1-times transfer (D17o D0) is used to transmit 1 pixel data with the 18-bit color depth information.
Version 1.0 Page 102 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.36 3-Line Serial Interface Different display data formats are available for three colors depth supported by the LCM listed below. 4k colors, RGB 4-4-4-bit input 65k colors, RGB 5-6-5-bit input 262k colors, RGB 6-6-6-bit input
8.8.37 Write data for 12-bit/pixel (RGB-4-4-4 bit input), 4K-Colors, 3Ah=”03h”
Note 1: Pixel data with the 12-bit color depth information Note 2: The most significant bits are: Rx3, Gx3 and Bx3 Note 3: The least significant bits are: Rx0, Gx0 and Bx0
Version 1.0 Page 103 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.8.38 Write data for 16-bit/pixel (RGB 5-6-5-bit input), 65K-Colors, 3Ah=”05h”
Note 1: Pixel data with the 16-bit color depth information Note 2: The most significant bits are: Rx4, Gx5 and Bx4 Note 3: The least significant bits are: Rx0, Gx0 and Bx0
8.8.39 Write data for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”
R11R12R13 R10 G11G12 G10 B11B12B13 B101 1 CSX RESX SDA SCL “1” D8 D7 D6 D5 D4 D3 D2 D1 D0 D8 D7 D6 D5 D4 D3 D2 D1 D0 D8 D7 D6 D5 D4 D3 D2 D 1 D0 Pixel n R1 G1 B1 R2 G2 B2 R3 G3 B3 18 bits Frame memory R14 G13G14G151 B14B15R15 n n n n n n Note 1: Pixel data with the 18-bit color depth information Note 2: The most significant bits are: Rx5, Gx5 and Bx5 Note 3: The least significant bits are: Rx0, Gx0 and Bx0
Version 1.0 Page 104 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.40 2 Data Lane Serial Interface Different display data formats are available for three colors depth supported by the LCM listed below. 4k colors, RGB 4-4-4-bit input 65k colors, RGB 5-6-5-bit input 262k colors, RGB 6-6-6-bit input
8.8.41 Write data for 12-bit/pixel (RGB 4-4-4-bit input), 4K-Colors, 3Ah=”03h”
Note 1: Pixel data with the 12-bit color depth information Note 2: The most significant bits are: Rx3, Gx3 and Bx3 Note 3: The least significant bits are: Rx0, Gx0 and Bx0
Version 1.0 Page 105 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.8.42 Write data for 16-bit/pixel (RGB 5-6-5-bit input), 65K-Colors, 3Ah=”05h”
R11R12R13 R101 R21R22R23 R20 G23G24G25 CSX RESX SDA SCL “1” D8 D7 D6 D5 D4 D3 D2 D1 D0 D8 D7 D6 D5 D4 D3 D2 D1 D0 Look”up table for 65k color data mapping (16 bits to 18 bits) 16 bits 16 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 18 bits Frame memory R14 G13G14G15 1 R24 G11G12 G10 B11B12B13 B101WRX D8 D7 D6 D5 D4 D3 D2 D1 D0 D8 D7 D6 D5 D4 D3 D2 D1 D0 Pixel n Pixel n+1 1B14 G21G22 G20 B21B22B23 B20B24 Note 1: Pixel data with the 16-bit color depth information Note 2: The most significant bits are: Rx4, Gx5 and Bx4 Note 3: The least significant bits are: Rx0, Gx0 and Bx0
8.8.43 Write data for 18-bit/pixel (RGB 6-6-6-bit input), 262K-Colors, 3Ah=”06h”
Note 1: Pixel data with the 18-bit color depth information Note 2: The most significant bits are: Rx5, Gx5 and Bx5 Note 3: The least significant bits are: Rx0, Gx0 and Bx0
Version 1.0 Page 106 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 8.8.44 4-Line Serial Interface Different display data formats are available for three colors depth supported by the LCM listed below. 4k colors, RGB 4-4-4-bit input 65k colors, RGB 5-6-5-bit input 262k colors, RGB 6-6-6-bit input
8.8.45 Write data for 12-bit/pixel (RGB 4-4-4-bit input), 4K-Colors, 3Ah=”03h”
R11R12R13 R10 G11G12G13 G10 B11B12B13 B10 R21R22R23 R20 G21G22G23 G20 B21B22B23 B20 CSX RESX SDA SCL “1” Pixel n Pixel n+1 Look”up table for 4096 color data mapping (12 bits to 18 bits) 12 bits 12 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 18 bits Frame memory D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 D/CX “1” Note 1. pixel data with the 12-bit color depth information Note 2. The most significant bits are: Rx3, Gx3 and Bx3 Note 3. The least significant bits are: Rx0, Gx0 and Bx0
Version 1.0 Page 107 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.8.46 Write data for 16-bit/pixel (RGB-5-6-5-bit input), 65K-Colors, 3Ah=”05h”
R11R12R13 R10 G11G12 G10 B11B12B13 B10 R21R22R23 R20 G23G24G25 CSX RESX SDA SCL “1” Pixel n Pixel n+1 Look”up table for 65k color data mapping (16 bits to 18 bits) 16 bits 16 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 18 bits Frame memory R14 G13G14G15 B14 R24 D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 D/CX “1” Note 1. pixel data with the 16-bit color depth information Note 2. The most significant bits are: Rx4, Gx5 and Bx4 Note 3. The least significant bits are: Rx0, Gx0 and Bx0
Version 1.0 Page 108 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.8.47 Write data for 18-bit/pixel (RGB-6-6-6-bit input), 262K-Colors, 3Ah=”06h”
Note 1. pixel data with the 18-bit color depth information Note 2. The most significant bits are: Rx5, Gx5 and Bx5 Note 3. The least significant bits are: Rx0, Gx0 and Bx0
Version 1.0 Page 109 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.9 RGB Interface
8.9.1 RGB interface Selection
The color format selection of RGB Interface for ST7789V2 is selected by setting the RIM and command 3Ah, DB[6:4]. RIM 3Ah, DB[6:4] RGB Interface Mode Data pins 0 110 18-bit 262K RGB Interface DB[17:0] 0 101 16-bit 65K RGB Interface DB[17:13], DB[11:1] 1 110 6-bit 262K RGB Interface DB[5:0] 1 101 6-bit 65K RGB Interface DB[5:0]
8.9.2 RGB Color Format
ST7789V2 supports two kinds of RGB interface, DE mode and HV mode, and 6bit/18bit data format. When DE mode is selected and the VSYNC, HSYNC, DOTCLK, DE, D[17:0] pins can be used; when HV mode is selected and the VSYNC, HSYNC, DOTCLK, D[17:0] pins can be used. When using RGB interface, only serial interface can be selected. 16-bit RGB interface Hardware suggestion, IM[3:0]=0101.
Version 1.0 Page 110 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Write data for 16-bit/pixel (RGB 5-6-5-bit input), 65K-Colors G1, Bit 4 G1, Bit 3 G1, Bit 2 G1, Bit 1 D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 16 bits 16 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 4 R1, Bit 3 R1, Bit 2 B1, Bit 4 B1, Bit 3 B1, Bit 2 B1, Bit 1 G2, Bit 3 G2, Bit 2 G2, Bit 1 G2, Bit 0 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 B2, Bit 3 B2, Bit 2 B2, Bit 1 B2, Bit 0 G3, Bit 3 G3, Bit 2 G3, Bit 1 G3, Bit 0 R3, Bit 3 R3, Bit 2 R3, Bit 1 R3, Bit 0 B3, Bit 3 B3, Bit 2 B3, Bit 1 B3, Bit 0 G4, Bit 3 G4, Bit 2 G4, Bit 1 G4, Bit 0 R4, Bit 3 R4, Bit 2 R4, Bit 1 R4, Bit 0 B4, Bit 3 B4, Bit 2 B4, Bit 1 B4, Bit 0 Pixel n+2 Pixel n+3 D17 D16 R2, Bit 4 R3, Bit 4 R4, Bit 4 R1, Bit 0 G1, Bit 5 G2, Bit 5 G2, Bit 4 G3, Bit 5 G3, Bit 4 G4, Bit 5 G4, Bit 4 G1, Bit 0 B2, Bit 4 B3, Bit 4 B4, Bit 4 G5, Bit 3 G5, Bit 2 G5, Bit 1 G5, Bit 0 R5, Bit 3 R5, Bit 2 R5, Bit 1 R5, Bit 0 B5, Bit 3 B5, Bit 2 B5, Bit 1 B5, Bit 0 R5, Bit 4 G5, Bit 5 G5, Bit 4 B5, Bit 4 Pixel n+4 R1, Bit 1 ” ” ” B1, Bit 0 ” ” ”
Version 1.0 Page 111 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 18-bit RGB interface hardware suggestion, IM[3:0]=0101. MCU Driver IC /RST RESX /CS CSX SCL DCX SDA SDA DB[17:0] VSYNC HSYNC DOTCLK ENABLE DB[17:0] VSYNC HSYNC DOTCLK ENABLE 18”bit RGB Interface
Version 1.0 Page 112 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Write data for 18-bit/pixel (RGB 6-6-6-bit input), 262K-Colors G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 D15 D14 D13 D12 D11 D10 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 G2, Bit 3 G2, Bit 2 G2, Bit 1 G2, Bit 0 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 B2, Bit 3 B2, Bit 2 B2, Bit 1 B2, Bit 0 G3, Bit 3 G3, Bit 2 G3, Bit 1 G3, Bit 0 R3, Bit 3 R3, Bit 2 R3, Bit 1 R3, Bit 0 B3, Bit 3 B3, Bit 2 B3, Bit 1 B3, Bit 0 G4, Bit 3 G4, Bit 2 G4, Bit 1 G4, Bit 0 R4, Bit 3 R4, Bit 2 R4, Bit 1 R4, Bit 0 B4, Bit 3 B4, Bit 2 B4, Bit 1 B4, Bit 0 Pixel n+2 Pixel n+3 D17 D16 R1, Bit 4 R2, Bit 4 R3, Bit 4 R4, Bit 4 G1, Bit 5 G1, Bit 4 G2, Bit 5 G2, Bit 4 G3, Bit 5 G3, Bit 4 G4, Bit 5 G4, Bit 4 B1, Bit 4 B2, Bit 4 B3, Bit 4 B4, Bit 4 G5, Bit 3 G5, Bit 2 G5, Bit 1 G5, Bit 0 R5, Bit 3 R5, Bit 2 R5, Bit 1 R5, Bit 0 B5, Bit 3 B5, Bit 2 B5, Bit 1 B5, Bit 0 R5, Bit 4 G5, Bit 5 G5, Bit 4 B5, Bit 4 Pixel n+4 R1, Bit 5 R2, Bit 5 R3, Bit 5 R4, Bit 5 R5, Bit 5 B1, Bit 5 B2, Bit 5 B3, Bit 5 B4, Bit 5 B5, Bit 5
Version 1.0 Page 113 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 6-bit RGB interface hardware suggestion, IM[3:0]=0101. Write data for 6-bit/pixel (RGB 5-6-5-bit input), 65K-Colors G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 G2, Bit 3 G2, Bit 2 G2, Bit 1 G2, Bit 0 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R1, Bit 4 R2, Bit 4G1, Bit 5 G1, Bit 4 G2, Bit 5 G2, Bit 4 B1, Bit 4 ” ”” Write data for 6-bit/pixel (RGB 6-6-6-bit input), 262K-Colors
Version 1.0 Page 114 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. G1, Bit 3 G1, Bit 2 G1, Bit 1 G1, Bit 0 Pixel n Pixel n+1 18 bits 18 bits R1 G1 B1 R2 G2 B2 R3 G3 B3 Frame memory R1, Bit 3 R1, Bit 2 R1, Bit 1 R1, Bit 0 B1, Bit 3 B1, Bit 2 B1, Bit 1 B1, Bit 0 G2, Bit 3 G2, Bit 2 G2, Bit 1 G2, Bit 0 R2, Bit 3 R2, Bit 2 R2, Bit 1 R2, Bit 0 R1, Bit 4 R2, Bit 4 G1, Bit 5 G1, Bit 4 G2, Bit 5 G2, Bit 4B1, Bit 4 R1, Bit 5 R2, Bit 5B1, Bit 5 Figure 23 RGB Interface Data Format
Version 1.0 Page 115 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.9.3 RGB Interface Definition
The display operation via the RGB interface is synchronized with the VSYNC, HSYNC, and DOTCLK signals. The data can be written only within the specified area with low power consumption by using window address function. The back porch and front porch are used to set the RGB interface timing. Figure 24 DRAM Access Area by RGB Interface Please refer to the following table for the setting limitation of RGB interface signals. Parameter Symbol Min. Typ. Max. Unit Horizontal Sync. Width hpw 2 10 hpw+hbp=31 Clock Horizontal Sync. Back Porch hbp 4 10 Clock Horizontal Sync. Front Porch hfp 2 38 - Clock Vertical Sync. Width vs 2 4 vs+vbp=127 Line Vertical Sync. Back Porch vbp 2 4 Line Vertical Sync. Front Porch vfp 2 8 - Line Note: Typical value are related to the setting of dot clock is 7MHz and frame rate is 70Hz.. If the setting of hpw is 10 dot clocks and hbp is 10 dot clocks, the setting of HBP in command B1h is 20 dot clocks
Version 1.0 Page 116 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. In with ram mode, hpw+hbp+hfp ≧22 In without ram mode, hpw+hbp ≧20 6bit RGB interface: Parameter Symbol Min. Typ. Max. Unit Horizontal Sync. Width hpw 6 30 hpw+hbp=93 Clock Horizontal Sync. Back Porch hbp 12 30 Clock Horizontal Sync. Front Porch hfp 6 60 - Clock Vertical Sync. Width vs 2 4 vs+vbp=127 Line Vertical Sync. Back Porch vbp 2 4 Line Vertical Sync. Front Porch vfp 2 8 - Line Note: Typical value are related to the setting of dot clock is 17MHz and frame rate is 60Hz, VDD=VDDI=2.8V.. In with ram mode, hpw+hbp+hfp ≧66 In without ram mode, hpw+hbp ≧60
8.9.4 RGB Interface Mode Selection
ST7789V2 supports two kinds of RGB interface, DE mode and HV mode. Each mode also can select with ram and without ram. The table shown below uses command B1h to select RGB interface mode. RCM[1:0] WO RGB Mode Data Path DE mode Ram
1 Shift register (without Ram)
8.9.5 RGB Interface Timing
The timing chart of RGB interface DE mode is shown as follows.
Version 1.0 Page 117 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Note: The setting of front porch and back porch in host must match that in IC as this mode. Figure 25 Timing Chart of Signals in RGB Interface DE Mode
Version 1.0 Page 118 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. The timing chart of RGB interface HV mode is shown as follows. Figure 26 Timing chart of RGB interface HV mod
Version 1.0 Page 119 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. The following are the functions not available in RGB Input Interface mode. Function RGB Interface I80 System Interface Partial display Not available Available Scroll function Not available Available Interlaced scan Not available Available Graphics operation function Not available Available VSYNC, HSYNC, and DOTCLK signals must be supplied during a display operation period. In RGB interface mode, the panel controlling signals are generated from DOTCLK, not the internal clock generated from the internal oscillator. In 6-bit RGB interface mode, each of RGB dots are transferred in synchronization with DOTCLK signals. In other words, one pixel data needs to take three DOTCLKs to transfer. In 6-bit RGB interface mode, the cycles of VSYNC, HSYNC, ENABLE, DOTCLK signals must be set correctly so that the data transfer is completed in units of pixels. When switching between the internal operation mode and the external display interface operation mode, follow the sequences below in setting instruction. In RGB interface mode, the front porch period continues until the next VSYNC input is detected after drawing one frame. In RGB interface mode, a RAM address is set in the address counter every frame on the falling edge of VSYNC.
Version 1.0 Page 120 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.10 VSYNC Interface
8.10.1 18-bit RGB Interface The ST7789V2 incorporates VSYNC interface, which enables motion pictures to be displayed with only the conventional system interface and the frame synchronization signal (VSYNC). This interface requires minimal changes from the conventional system to display motion pictures.In this interface the internal display operation is synchronized with VSYNC. Data for display is written to RAM via the system interface with higher speed than for internal display operation. This method enables tearing-free display of motion pictures with the conventional interface. Figure 27 Data transmission through VSYNC interface Display Area (320 Lines) Back Porch (VBP) Front Porch (VFP) VSYNC Display Scan RAM Write Figure 28 Operation through VSYNC Interface
Version 1.0 Page 121 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Display operation can be achieved by using the internal clock generated by the internal oscillator and the VSYNC input. Because all the data for display is written to RAM, only the data to be rewritten is transferred. This method reduces the amount of data transferred during motion picture display operation. Write Data to Frame Memory Source Gate320 Gate1 Gate2 D[17:0]
1 Line
Figure 29 Timing Diagram of VSYNC Interface VSYNC interface requires taking the minimum speed for RAM writing via the system interface and the frequency of the internal clock into consideration. RAM writing should be performed with higher speed than the result obtained from the calculation shown below. The internal memory writing address counter is reset by VSYNC. So, insure interval time between VSYNC falling and DRAM data writing. Note: 1. VSYNC period should always be constant. If not, some degradation of display such as flicker may occur in LCD system. 2. Display data don’t need to be written for every VSYNC period. For example, any system is working under 60Hz frame rate and 30-fps motion picture condition. So being written display data for every other frame would be enough.
Version 1.0 Page 122 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.10.2 VSYNC Interface Mode
Figure 30 Operation for Leading Mode of VSYNC Interface Lagging Mode Figure 31 Operation for Lagging Mode of VSYNC Interface
Version 1.0 Page 123 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Notes: 1. When RAM writing does not start immediately after the falling edge of VSYNC, the time between the falling edge of VSYNC and the RAM writing start timing must also be considered. 1. The minimum DRAM write speed must be satisfied and the frequency variation must be taken into consideration. 2. The display frame rate is determined by the VSYNC signal and the period of VSYNC must be longer than the scan period of an entire display. 3. When switching from the internal clock operation mode to the VSYNC interface mode or inversely, the switching starts from the next VSYNC cycle, i.e. after completing the display of the frame. 4. The partial display, vertical scroll, and interlaced scan functions are not available in VSYNC interface mode and set the AM bit to “0” to transfer display data.
Version 1.0 Page 124 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.11 Display Data RAM
8.11.1 Configuration
The display module has an integrated 240x320x18-bit graphic type static RAM. This 1382400-bit memory allows storing on-chip a 240xRGBx320 image with an 18-bpp resolution (262K-color). There will be no abnormal visible effect on the display when there is a simultaneous Panel Read and Interface Read or Write to the same location of the Frame Memory. Display data RAM (240 x 320 x 18nbits) TFnLCD panel (240 x RGB x 320) Line address counter Scan address counter Host interface MCU I/F LUT Row address counter Column address counter Figure 32 Display data RAM organization
Version 1.0 Page 125 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.11.2 Memory to display address mapping
Data control command Column (MADCTR) MX=0 0 1 239 (MADCTR) MX=1 239 238 0 Color R G B R G B R G B Data Page (MADCTR) MY=0 (MADCTR) MY=1 0 319 1 318 2 317 3 316 4 315 5 314 6 313 7 312 : : 312 7 313 6 314 5 315 4 316 3 317 2 318 1 319 0 Source output 0 1 2 3 4 5 717 718 719
Version 1.0 Page 126 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.12 Address Control
The address counter sets the addresses of the display data RAM for writing and reading. Data is written pixel-wise into the RAM matrix of DRIVER. The data for one pixel or two pixels is collected (RGB 6-6-6-bit), according to the data formats. As soon as this pixel-data information is complete the “Write access” is activated on the RAM. The locations of RAM are addressed by the address pointers. The address ranges are X=0 to X=239 (Efh) and Y=0 to Y=319 (13Fh). Addresses outside these ranges are not allowed. Before writing to the RAM, a window must be defined that will be written. The window is programmable via the command registers XS, YS designating the start address and XE, YE designating the end address. For example the whole display contents will be written, the window is defined by the following values: XS=0 (0h) YS=0 (0h) and XE=239 (Efh), YE=319 (13Fh). In vertical addressing mode (MV=1), the Y-address increments after each byte, after the last Y-address (Y=YE), Y wraps around to YS and X increments to address the next column. In horizontal addressing mode (V=0), the X-address increments after each byte, after the last X-address (X=XE), X wraps around to XS and Y increments to address the next row. After the every last address (X=XE and Y=YE) the address pointers wrap around to address (X=XS and Y=YS). For flexibility in handling a wide variety of display architectures, the commands “CASET, RASET and MADCTL”, define flags MX and MY , which allows mirroring of the X-address and Y-address. All combinations of flags are allowed. Section 8.12 show the available combinations of writing to the display RAM. When MX, MY and MV will be changed the data bust be rewritten to the display RAM. For each image condition, the controls for the column and row counters apply as below Condition Column Counter Row Counter When RAMWR/RAMRD command is accepted Return to “Start Column (XS)” Return to “Start Row (YS)” Complete Pixel Read / Write action Increment by 1 N o change The Column counter value is larger than “End Column (XE)” Return to “Start Column (XS)” Increment by 1 The Column counter value is larger than “End Column (XE)” and the Row counter value is larger than “End Row (YE)” Return to “Start Column (XS)” Return to “Start Row (YS)”
Version 1.0 Page 127 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Display Data Direction MADCTR Parameter Image in the Host (MPU) Image in the Driver (DDRAM) MV MX MY Normal 0 0 0 Y-Mirror 0 0 1 X-Mirror 0 1 0 X-Mirror Y-Mirror 0 1 1 X-Y Exchange 1 0 0 X-Y Exchange Y-Mirror 1 0 1 X-Y Exchange X-Mirror 1 1 0 X-Y Exchange X-Mirror Y-Mirror 1 1 1 Figure 33 Display data RAM organization
Version 1.0 Page 128 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.13 Normal Display On or Partial Mode On, Vertical Scroll Off
In this mode, contents of the frame memory within an area where column address is 00h to 83h and row address is 00h to 83h is displayed. To display a dot on leftmost top corner, store the dot data at (column address, row address) = (0,0). Example1) Normal Display On Example2) Partial Display On: PSL[15:0] = 0004h, PEL[15:0] = 013Ch, MADCTR (ML)=0
Version 1.0 Page 129 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
Version 1.0 Page 130 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.14 Vertical Scroll Mode
8.14.1 Rolling scroll
There is just one types of vertical scrolling, which are determined by the commands “Vertical Scrolling Definition” (33h) and “Vertical Scrolling Start Address” (37h). Figure 34 Rolling Scroll Definition When Vertical Scrolling Definition Parameters (TFA+VSA+BFA) =320. In this case, ‘rolling’ scrolling is applied as shown below. All the memory contents will be used. Example1) Panel size=240 x 320, TFA =3, VSA=315, BFA=2, SSA=4, MADCTR ML=0: Rolling Scroll
Version 1.0 Page 131 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Example2) Panel size=132 x 132, TFA =2, VSA=315, BFA=3, SSA=4, MADCTR ML=1: Rolling Scroll (TFA and BFA are exchanged)
Version 1.0 Page 132 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.14.2 Vertical Scroll Example
There are 2 types of vertical scrolling, which are determined by the commands “Vertical Scrolling Definition” (33h) and “Vertical Scrolling Start Address” (37h). Case 1: TFA + VSA + BFA<320 N/A. Do not set TFA + VSA + BFA<320. In that case, unexpected picture will be shown. Case 2: TFA + VSA + BFA=320 (Rolling Scrolling) Example1) When MADCTR parameter ML=”0”, TFA=0, VSA=320, BFA=0 and VSCSAD=40. 2 1 2 1
Version 1.0 Page 133 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Example2) When MADCTR parameter ML=”1”, TFA=10, VSA=310, BFA=0 and VSCSAD=30. 1 323
Version 1.0 Page 134 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.15 Tearing Effect
The Tearing Effect output line supplies to the MPU a Panel synchronization signal. This signal can be enabled or disabled by the Tearing Effect Line Off & On commands. The mode of the Tearing Effect signal is defined by the parameter of the Tearing Effect Line On command. The signal can be used by the MPU to synchronize Frame Memory Writing when displaying video images.
8.15.1 Tearing effect line modes
Mode 1, the Tearing Effect Output signal consists of V-Blanking Information only: tvdh= The LCD display is not updated from the Frame Memory tvdl= The LCD display is updated from the Frame Memory (except Invisible Line – see above) Mode 2, the Tearing Effect Output signal consists of V-Blanking and H-Blanking Information, there is one V-sync and 320 H-sync pulses per field. thdh= The LCD display is not updated from the Frame Memory thdl= The LCD display is updated from the Frame Memory (except Invisible Line – see above) Note: During Sleep In Mode, the Tearing Output Pin is active Low.
Version 1.0 Page 135 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.15.2 Tearign effect line timings
The Tearing Effect signal is described below: Table 17 AC characteristics of Tearing Effect Signal Idle Mode Off (Frame Rate = 60 Hz, Ta=25°C) Note: The timings in Table 15 apply when MADCTL ML=0 and ML=1 The signal’s rise and fall times (tf, tr) are stipulated to be equal to or less than 15ns. The Tearing Effect Output Line is fed back to the MPU and should be used as shown below to avoid Tearing Effect: Symbol Parameter min max unit description tvdl Vertical Timing Low Duration 13 - ms tvdh Vertical Timing High Duration 1000 - µs thdl Horizontal Timing Low Duration 33 - µs thdh Horizontal Timing Low Duration 25 500 µs
Version 1.0 Page 136 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.15.3 Example 1: MPU Write is faster than panel read
Data write to Frame Memory is now synchronized to the Panel Scan. It should be written during the vertical sync pulse of the Tearing Effect Output Line. This ensures that data is always written ahead of the panel scan and each Panel Frame refresh has a complete new image:
Version 1.0 Page 137 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.15.4 Example 2: MPU write is slower than panel read
The MPU to Frame Memory write begins just after Panel Read has commenced i.e. after one horizontal sync pulse of the Tearing Effect Output Line. This allows time for the image to download behind the Panel Read pointer and finishing download during the subsequent Frame before the Read Pointer “catches” the MPU to Frame memory write position. B
Version 1.0 Page 138 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.16 Power ON/OFF Sequence
VDDI and VDD can be applied in any order. VDD and VDDI can be power down in any order. During power off, if LCD is in the Sleep Out mode, VDD and VDDI must be powered down minimum 120msec after RESX has been released. During power off, if LCD is in the Sleep In mode, VDDI or VDD can be powered down minimum 0msec after RESX has been released. CSX can be applied at any timing or can be permanently grounded. RESX has priority over CSX. Note 1: There will be no damage to the display module if the power sequences are not met. Note 2: There will be no abnormal visible effects on the display panel during the Power On/Off Sequences. Note 3: There will be no abnormal visible effects on the display between end of Power On Sequence and before receiving Sleep Out command. Also between receiving Sleep In command and Power Off Sequence. Note 4: If RESX line is not held stable by host during Power On Sequence as defined in the sequence below, then it will be necessary to apply a Hardware Reset (RESX) after Host Power On Sequence is complete to ensure correct operation. Otherwise function is not guaranteed. The power on/off sequence is illustrated below Timing when the latter signal rises up to 90% of its typical value. e.g. When VDD comes later, this timing is defined at the cross point of 90% of 2.75V, not 90% of 2.6V. Timing when the latter signal falls up to 90% of its typical value. e.g. When VDD comes later, this timing is defined at the cross point of 90% of 2.75V, not 90% of 2.6V. H or L Tr PW”CSX = +/” no limit Tf PW”CSX = +/” no limit 30% 30% Tr PW”RESX = + no limit Tr PW”RESX = + no limit Tf PW”RESX1 = min 120ms Tf PW”RESX2 = min 0ms TfPW”RESx1 is applied to RESX falling in the Sleep Out Mode. TfPW”RESx2 is applied to RESX falling in the Sleep In Mode. VDD VDDI CSX RESX (Power down in sleep”out mode) RESX (Power down in sleep”in mode) Tr PW = +/” no limit Tf PW = +/” no limit
Version 1.0 Page 139 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.16.1 Uncontrolled Power Off
The uncontrolled power-off means a situation which removed a battery without the controlled power off sequence. It will neither damage the module or the host interface. If uncontrolled power-off happened, the display will go blank and there will not any visible effect on the display (blank display) and remains blank until “Power On Sequence” powers it up.
Version 1.0 Page 140 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.17 Power Level Definition
8.17.1 Power Level
6 level modes are defined they are in order of Maximum Power consumption to Minimum Power Consumption 1. Normal Mode On (full display), Idle Mode Off, Sleep Out. In this mode, the display is able to show maximum 262,144 colors. 2. Partial Mode On, Idle Mode Off, Sleep Out. In this mode part of the display is used with maximum 262,144 colors. 3. Normal Mode On (full display), Idle Mode On, Sleep Out. In this mode, the full display area is used but with 8 colors. 4. Partial Mode On, Idle Mode On, Sleep Out. In this mode, part of the display is used but with 8 colors. 5. Sleep In Mode In this mode, the DC: DC converter, internal oscillator and panel driver circuit are stopped. Only the MCU interface and memory works with VDDI power supply. Contents of the memory are safe. Note: Transition between modes 1-5 is controllable by MCU commands. Mode 6 is entered only when both Power supplies are removed.
Version 1.0 Page 141 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.18 Power Flow Chart
Normal display mode on = NOR ON Partial display mode on = PTL ON Idle mode off = IDM OFF Idle mode on = IDM ON Sleep out = SLP OUT Sleep in = SLP IN
Version 1.0 Page 142 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.19 Gamma Correction
ST7789V2 incorporate the gamma correction function to display 262,244 colors for the LCD panel. The gamma correction is performed with 3 groups of registers, which are gradient adjustment, contrast adjustment and fine- adjustment registers for positive and negative polarities, and RGB can be adjusted individually. Figure 35 Gray scale Voltage Generation (Positive)
Version 1.0 Page 143 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Figure 36 Relationship between Source Output and VCOM Percentage adjustment: J0P[1:0], J1P[1:0], J0N[1:0], J1N[1:0] these register are used to adjust the voltage level of interpolation point. The following table is the detail description. J0P[1:0]/J0N[1:0]: 00h 01h 02h 03h VP3/VN3 50% 56% 50% 60% VP5/VN5 50% 44% 50% 42% VP7/VN7 86% 71% 80% 66% VP8/VN8 71% 57% 63% 49% VP9/VN9 57% 40% 49% 34% VP10/VN10 43% 29% 34% 23% VP11/VN11 29% 17% 20% 14% VP12/VN12 14% 6% 9% 6% J1P[1:0]/J1N[1:0]: 00h 01h 02h 03h VP51/VN51 86% 86% 86% 89% VP52/VN52 71% 71% 77% 80% VP53/VN53 57% 60% 63% 69% VP54/VN54 43% 46% 46% 51% VP55/VN55 29% 34% 31% 37% VP56/VN56 14% 17% 14% 20% VP58/VN58 50% 56% 47% 47% VP60/VN60 50% 50% 50% 53% Table 18 voltage level percentage adjustment description
Version 1.0 Page 144 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Source voltage of positive gamma level Gamma level Related Register Formula VP0 V0P[3:0] (VAP-VBP)*(129R-V0P[3:0]R)/129R+VBP VP1 V1P[5:0] (VAP-VBP)*(128R-V1P[5:0]R)/129R+VBP VP2 V2P[5:0] (VAP-VBP)*(128R-V2P[5:0]R)/129R+VBP VP3 J0P[1:0] (VP2-VP4)*J0P[1:0]+VP4 VP4 V4P[4:0] (VP2-VP20)*(57R-V4P[4:0])/60R+VP20 VP5 J0P[1:0] (VP4-VP6)*J0P[1:0]+VP6 VP6 V6P[4:0] (VP2-VP20)*(47R-V6P[4:0])/60R+VP20 VP7 J0P[1:0] (VP6-VP13)*J0P[1:0]+VP13 VP8 J0P[1:0] (VP6-VP13)*J0P[1:0]+VP13 VP9 J0P[1:0] (VP6-VP13)*J0P[1:0]+VP13 VP10 J0P[1:0] (VP6-VP13)*J0P[1:0]+VP13 VP11 J0P[1:0] (VP6-VP13)*J0P[1:0]+VP13 VP12 J0P[1:0] (VP6-VP13)*J0P[1:0]+VP13 VP13 V13P[3:0] (VP2-VP20)*(21R-V13P[3:0])/60R+VP20 VP20 V20P[6:0] (VAP-VBP)*(128R-V20P[6:0]R)/129R+VBP VP27 V27P[2:0] (VP20-VP43)*(20R-V27P[2:0])/25R+VP43 VP36 V36P[2:0] (VP20-VP43)*(11R-V36P[2:0])/25R+VP43 VP43 V43P[6:0] (VAP-VBP)*(128R-V43P[6:0]R)/129R+VBP VP50 V50P[3:0] (VP43-VP61)*(54R-V50P[3:0])/60R+VP61 VP51 J1P[1:0] (V5P0-VP57)*J1P[1:0]+VP57
Version 1.0 Page 145 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. VP52 J1P[1:0] (VP50-VP57)*J1P[1:0]+VP57 VP53 J1P[1:0] (VP50-VP57)*J1P[1:0]+VP57 VP54 J1P[1:0] (VP50-VP57)*J1P[1:0]+VP57 VP55 J1P[1:0] (VP50-VP57)*J1P[1:0]+VP57 VP56 J1P[1:0] (VP50-VP57)*J1P[1:0]+VP57 VP57 V57P[4:0] (VP43-VP61)*(44R-V57P[4:0])/60R+VP61 VP58 J1P[1:0] (VP57-VP59)*J1P[1:0]+VP59 VP59 V59P[4:0] (VP43-VP61)*(34R-V59P[4:0])/60R+VP61 VP60 J1P[1:0] (VP59-VP61)*J1P[1:0]+VP61 VP61 V61P[5:0] (VAP-VBP)*(64R-V61P[5:0]R)/129R+VBP VP62 V62P[5:0] (VAP-VBP)*(64R-V62P[5:0]R)/129R+VBP VP63 V63P[3:0] (VAP-VBP)*(23R-V63P[3:0]R)/129R+VBP Source voltage of negative gamma level Gamma level Related Register Formula VN0 V0N[3:0] VBN-(VBN-VAN)*(129R-V0N[3:0]R)/129R VN1 V1N[5:0] VBN-(VBN-VAN)*(128R-V1N[5:0]R)/129R VN2 V2N[5:0] VBN-(VBN-VAN)*(128R-V2N[5:0]R)/129R VN3 J0N[1:0] (VN2-VN4)*J0N[1:0]+VN4 VN4 V4N[4:0] (VN2-VN20)*(57R-V4N[4:0])/60R+VN20 VN5 J0N[1:0] (VN4-VN6)*J0N[1:0]+VN6 VN6 V6N[4:0] (VN2-VN20)*(47R-V6N[4:0])/60R+VN20 VN7 J0N[1:0] (VN6-VN13)*J0N[1:0]+VN13 VN8 J0N[1:0] (VN6-VN13)*J0N[1:0]+VN13 VN9 J0N[1:0] (VN6-VN13)*J0N[1:0]+VN13 VN10 J0N[1:0] (VN6-VN13)*J0N[1:0]+VN13 VN11 J0N[1:0] (VN6-VN13)*J0N[1:0]+VN13 VN12 J0N[1:0] (VN6-VN13)*J0N[1:0]+VN13 VN13 V13N[3:0] (VN2-VN20)*(21R-V13N[3:0])/60R+VN20 VN20 V20N[6:0] VBN-(VBN-VAN)*(128R-V20N[6:0]R)/129R VN27 V27N[2:0] (VN20-VN43)*(20R-V27N[2:0])/25R+VN43 VN36 V36N[2:0] (VN20-VN43)*(11R-V36N[2:0])/25R+VN43
Version 1.0 Page 146 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. VN43 V43N[6:0] VBN-(VBN-VAN)*(128R-V43N[6:0]R)/129R VN50 V50N[3:0] (VN43-VN61)*(54R-V50N[3:0])/60R+VN61 VN51 J1N[1:0] (V5N0-VN57)*J1N[1:0]+VN57 VN52 J1N[1:0] (VN50-VN57)*J1N[1:0]+VN57 VN53 J1N[1:0] (VN50-VN57)*J1N[1:0]+VN57 VN54 J1N[1:0] (VN50-VN57)*J1N[1:0]+VN57 VN55 J1N[1:0] (VN50-VN57)*J1N[1:0]+VN57 VN56 J1N[1:0] (VN50-VN57)*J1N[1:0]+VN57 VN57 V57N[4:0] (VN43-VN61)*(44R-V57N[4:0])/60R+VN61 VN58 J1N[1:0] (VN57-VN59)*J1N[1:0]+VN59 VN59 V59N[4:0] (VN43-VN61)*(34R-V59N[4:0])/60R+VN61 VN60 J1N[1:0] (VN59-VN61)*J1N[1:0]+VN61 VN61 V61N[5:0] VBN-(VBN-VAN)*(64R-V61N[5:0]R)/129R VN62 V62N[5:0] VBN-(VBN-VAN)*(64R-V62N[5:0]R)/129R VN63 V63N[3:0] VBN-(VBN-VAN)*(23R-V63N[3:0]R)/129R
Version 1.0 Page 147 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.20 Gray voltage generator for digital gamma correction
ST7789V2 digital gamma function can implement the RGB gamma correction independently. ST7789V2 utilizes look-up table of digital gamma to change ram data, and then display the changed data from source driver. The following diagram shows the data flow of digital gamma. Figure 37 Block diagram of digital gamma There are 2 registers and each register has 64 bytes to set R, G, B gamma independently. When bit DGMEN be set to 1, R and B gamma will be mapped via look-up table of digital gamma to gray level voltage.
Version 1.0 Page 148 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.21 Display Dimming
8.21.1 General Description
A dimming function (how fast to change the brightness from old to new level and what are brightness levels during the change) is used when changing from one brightness level to another. This dimming function curve is the same in increment and decrement. The basic idea is described below. Dimming function can be enable and disable. See “Write CTRL Display (53h)” (bit DD) for more information.
8.21.2 Dimming Requirement
Dimming function in the display module should be implemented so that 400-600ms is used for the transition between the original brightness value and the target brightness value. The transferring time steps between these two brightness values are equal making the transition linear. The dimming function is working similarly in both upward and downward directions. An upward example is illustrate below
Version 1.0 Page 149 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
Version 1.0 Page 150 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.21.3 Definition of brightness transition time
/circle6 Shorter transition time than 500ms. There is some stable time between transitions. Below drawing is for transition time: 400ms. /circle6 Longer transition time than 500ms There is no any stable time between transitions. Below drawing is for transition time: 600ms.
Version 1.0 Page 151 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
Version 1.0 Page 152 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.22 Content Adaptive Brightness Control (CABC)
8.22.1 Definition of CABC
A Content Adaptive Brightness Control function can be used to reduce the power consumption of the luminance source. Content adaptation means that content gray level scale can be increased while simultaneously lowering brightness of the backlight to achieve same perceived brightness. The adjusted gray level scale and thus the power consumption reduction Definition of Modes and target power reduction ratio: /circle6 Off mode: Content Adaptive Brightness Control functionality is totally off. /circle6 UI [User interface] image mode: Optimized for UI image. It is kept image quality as much as possible. Target power consumption reduction ratio: 10% or less. /circle6 Still picture mode: Optimized for still picture. Some image quality degradation would be acceptable. Target power consumption reduction ratio: more than 30%. /circle6 Moving image mode: Optimized for moving image. It is focused on the biggest power reduction with image quality degradation. Target power consumption reduction ratio: more than 30%. Note 1: Updating partial area of the image data should be supported by CABC functionality. Note 2: Processing power consumption of CABC should be minimized. Note 3: Customer need program OTP GAMMA when using CABC.
Version 1.0 Page 153 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. The transition time for dimming function is illustrated below. /circle6 Content Adaptive Brightness Control Display brightness is changed, according to the image contents. The following graph mentions the case of displaying three different images. /circle6 Image A: -20% brightness reduction /circle6 Image B: -30% brightness reduction /circle6 Image C: -30% brightness reduction Transition time from the previous image to the current displayed image is “transition time A”. Image A Brightness reduction ratio: n20% Image B Brightness reduction ratio: n30% Image C Brightness reduction ratio: n10% 50% 100% 80% Display brightness Transition time A Time Content Adaptive Brightness Control Transition time A Transition time A 70% 90%
Version 1.0 Page 154 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. /circle6 Manual brightness setting and Dimming function
Version 1.0 Page 155 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. /circle6 Combine Display brightness Green line in the following graph is for the output brightness of display. It is combined with both display brightness, which are defined in the above graphs. Maximum transition time is transition time A+B. Display brightness Brightness level calculates with the following formula. Display Output brightness = Manual Brightness setting * CABC brightness ratio Manual Brightness setting Brightness ratio [CABC] Display Output brightness Case 1 85% 80% 68% Case 2 60% 70% 42% Case 3 85% 90% 76.5% Transition time from the current brightness to target brightness is A+B in the worst case.
Version 1.0 Page 156 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
8.22.2 Minimum brightness setting of CABC function
CABC function is automatically reduced backlight brightness based on image contents. In the case of the combination with the LABC or manual brightness setting, display brightness is too dark. It must affect to image quality degradation. CABC minimum brightness setting is to avoid too much brightness reduction. When CABC is active, CABC can not reduce the display brightness to less than CABC minimum brightness setting. If CABC algorithm works without any abnormal visual effect, image processing function can operate even when the brightness can not be changed. This function does not affect to the other function, manual brightness setting. Manual brightness can be set the display brightness to less than CABC minimum brightness. Smooth transition and dimming function can be worked as normal. When display brightness is turned off (BCTRL=0 of “9.1.39 Write CTRL Display (53h)”), CABC minimum brightness setting is ignored. “9.1.44 Read CABC minimum brightness (5Fh)” always read the setting value of “9.1.43 Write CABC minimum brightness (5Eh)”. WRCABC (55h) Function RDCABCMB (5Fh) Image Sleep-in NA WRCABCMB (5Eh) CABC off 00b Disable WRCABCMB (5Eh) Original CABC on 01b/10b/11b Enable WRCABCMB (5Eh) CABC modified Brightness level calculates with the following formula. Display Output Brightness = Manual brightness setting * CABC brightness ratio Below drawing is for the explanation of the CABC minimum brightness setting.
Version 1.0 Page 157 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. CABC minimum brightness value = 51 (33h: 20% display brightness) Display Brightness [manual setting] Brightness ratio [CABC] Calculation result of the display brightness formula Display Output Brightness Image Case 1 50% 70% 35% 35% CABC modified Case 2 20% 70% 14% 20% CABC modified Case 3 50% 70% 35% 35% CABC modified At the case 2, the calculation result of the display brightness is 14%. CABC minimum brightness value is set to 20% brightness. Actual display brightness is 20% as the CABC minimum brightness setting.
Version 1.0 Page 158 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9 COMMAND
9.1 System Function Command Table 1
Instruction D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 Hex Function NOP 0 ↑ 1 - 0 0 0 0 0 0 0 0 (00h) No operation SWRESET 0 ↑ 1 - 0 0 0 0 0 0 0 1 (01h) Software reset RDDID 0 ↑ 1 - 0 0 0 0 0 1 0 0 (04h) Read display ID 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - ID17 ID16 ID15 ID14 ID13 ID12 ID11 ID10 ID1 read 1 1 ↑ - ID27 ID26 ID25 ID24 ID23 ID22 ID21 ID20 ID2 read 1 1 ↑ - ID37 ID36 ID35 ID34 ID33 ID32 ID31 ID30 ID3 read RDDST 0 ↑ 1 - 0 0 0 0 1 0 0 1 (09h) Read display status 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - BSTON MY MX MV ML RGB MH ST24 - 1 1 ↑ - ST23 IFPF2 IFPF1 IFPF0 IDMON PTLON SLOUT NORON - 1 1 ↑ - ST15 ST14 INVON ST12 ST11 DISON TEON GCS2 - 1 1 ↑ - GCS1 GCS0 TEM ST4 ST3 ST2 ST1 ST0 - RDDPM 0 ↑ 1 - 0 0 0 0 1 0 1 0 (0Ah) Read display power 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - BSTON IDMON PTLON SLPOUT NORON DISON 0 0 RDD MADCTL 0 ↑ 1 - 0 0 0 0 1 0 1 1 (0Bh) Read display 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - MY MX MV ML RGB MH 0 0 - RDD COLMOD 0 ↑ 1 - 0 0 0 0 1 1 0 0 (0Ch) Read display pixel 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - 0 D6 D5 D4 0 D2 D1 D0 - RDDIM 0 ↑ 1 - 0 0 0 0 1 1 0 1 (0Dh) Read display image 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - VSSON 0 INVON 0 0 GC2 GC1 GC0 - RDDSM 0 ↑ 1 - 0 0 0 0 1 1 1 0 (0Eh) Read display signal 1 1 ↑ - - - - - - - - - Dummy read
Version 1.0 Page 159 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Instruction D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 Hex Function 1 1 ↑ - TEON TEM 0 0 0 0 0 0 - RDDSDR 0 ↑ 1 - 0 0 0 0 1 1 1 1 (0Fh) Read display self-diagnostic result 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - D7 D6 0 0 0 0 0 0 - SLPIN 0 ↑ 1 - 0 0 0 1 0 0 0 0 (10h) Sleep in SLPOUT 0 ↑ 1 - 0 0 0 1 0 0 0 1 (11h) Sleep out PTLON 0 ↑ 1 - 0 0 0 1 0 0 1 0 (12h) Partial mode on NORON 0 ↑ 1 - 0 0 0 1 0 0 1 1 (13h) Partial off (Normal) INVOFF 0 ↑ 1 - 0 0 1 0 0 0 0 0 (20h) Display inversion off INVON 0 ↑ 1 - 0 0 1 0 0 0 0 1 (21h) Display inversion on GAMSET 0 ↑ 1 - 0 0 1 0 0 0 0 1 (26h) Display inversion on 1 ↑ 1 - 0 0 0 0 GC3 GC2 GC1 GC0 DISPOFF 0 ↑ 1 - 0 0 1 0 1 0 0 0 (28h) Display off DISPON 0 ↑ 1 - 0 0 1 0 1 0 0 1 (29h) Display on CASET 0 ↑ 1 - 0 0 1 0 1 0 1 0 (2Ah) Column address set 1 ↑ 1 - XS15 XS14 XS13 XS12 XS11 XS10 XS9 XS8 X address start: ≦ ≦0 XS X 1 ↑ 1 XS7 XS6 XS5 XS4 XS3 XS2 XS1 XS0 1 ↑ 1 XE15 XE14 XE13 XE12 XE11 XE10 XE9 XE8 X address start: ≦ ≦S XE X 1 ↑ 1 XE7 XE6 XE5 XE4 XE3 XE2 XE1 XE0 RASET 0 ↑ 1 - 0 0 1 0 1 0 1 1 (2Bh) Row address set 1 ↑ 1 - YS15 YS14 YS13 YS12 YS11 YS10 YS9 YS8 Y address start: ≦ ≦0 YS Y 1 ↑ 1 YS7 YS6 YS5 YS4 YS3 YS2 YS1 YS0 1 ↑ 1 YE15 YE14 YE13 YE12 YE11 YE10 YE9 YE8 Y address start: ≦ ≦S YE Y 1 ↑ 1 YE7 YE6 YE5 YE4 YE3 YE2 YE1 YE0 RAMWR 0 ↑ 1 - 0 0 1 0 1 1 0 0 (2Ch) Memory write Write data 1 ↑ 1 Dx[17:8] Dx[7] Dx[6] Dx[5] Dx[4] Dx[3] Dx[2] Dx[1] Dx[0] 1 ↑ 1 Dn[17:8] Dn[7] Dn[6] Dn[5] Dn[4] Dn[3] Dn[2] Dn[1] Dn[0] RAMRD 0 ↑ 1 - 0 0 1 0 1 1 1 0 (2Eh) Memory read
Version 1.0 Page 160 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Instruction D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 Hex Function 1 1 ↑ - - - - - - - - - Dummy read Read data 1 1 ↑ Dx[17:8] Dx[7] Dx[6] Dx[5] Dx[4] Dx[3] Dx[2] Dx[1] Dx[0] 1 1 ↑ Dn[17:8] Dn[7] Dn[6] Dn[5] Dn[4] Dn[3] Dn[2] Dn[1] Dn[0] PTLAR 0 ↑ 1 - 0 0 1 1 0 0 0 0 (30h) Partial sart/end address set 1 ↑ 1 - PSL15 PSL14 PSL13 PSL12 PSL11 PSL10 PSL9 PSL8 Partial start address: (0, 1,2, ..P) 1 ↑ 1 - PSL7 PSL6 PSL5 PSL4 PSL3 PSL2 PSL1 PSL0 1 ↑ 1 - PEL15 PEL14 PEL13 PEL12 PEL11 PEL10 PEL9 PEL8 Partial end address (0, 1,2, 3, , P) 1 ↑ 1 - PEL7 PEL6 PEL5 PEL4 PEL3 PEL2 PEL1 PEL0 VSCRDEF 0 ↑ 1 - 0 0 1 1 0 0 1 1 (33h) Vertical scrolling definition 1 ↑ 1 - TFA15 TFA14 TFA13 TFA12 TFA11 TFA10 TFA9 TFA8 1 ↑ 1 - TFA7 TFA6 TFA5 TFA4 TFA3 TFA2 TFA1 TFA0 1 ↑ 1 - VSA15 VSA14 VSA13 VSA12 VSA11 VSA10 VSA9 VSA8 1 ↑ 1 - VSA7 VSA6 VSA5 VSA4 VSA3 VSA2 VSA1 VSA0 1 ↑ 1 - BFA15 BFA14 BFA13 BFA12 BFA11 BFA10 BFA9 BFA8 1 ↑ 1 - BFA7 BFA6 BFA5 BFA4 BFA3 BFA2 BFA1 BFA0 TEOFF 0 ↑ 1 - 0 0 1 1 0 1 0 0 (34h) Tearing effect line off TEON 0 ↑ 1 - 0 0 1 1 0 1 0 1 (35h) Tearing effect line on MADCTL 0 ↑ 1 - 0 0 1 1 0 1 1 0 (36h) Memory data access control 1 ↑ 1 - MY MX MV ML RGB 0 0 0 - VSCRSADD 0 ↑ 1 - 0 0 1 1 0 1 1 1 (37h) Vertical scrolling start address 1 ↑ 1 - VSP15 VSP14 VSP13 VSP12 VSP11 VSP10 VSP9 VSP8 1 ↑ 1 - VSP7 VSP6 VSP5 VSP4 VSP3 VSP2 VSP1 VSP0 IDMOFF 0 ↑ 1 - 0 0 1 1 1 0 0 0 (38h) Idle mode off IDMON 0 ↑ 1 - 0 0 1 1 1 0 0 1 (39h) Idle mode on
Version 1.0 Page 161 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Instruction D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 Hex Function COLMOD 0 ↑ 1 - 0 0 1 1 1 0 1 0 (3Ah) Interface pixel format 1 ↑ 1 - 0 D6 D5 D4 0 D2 D1 D0 Interface format RAMWRC 0 ↑ 1 - 0 0 1 1 1 1 0 0 (3Ch) Memory write continue Write data 1 ↑ 1 Dx[17:8] Dx[7] Dx[6] Dx[5] Dx[4] Dx[3] Dx[2] Dx[1] Dx[0] 1 ↑ 1 Dn[17:8] Dn[7] Dn[6] Dn[5] Dn[4] Dn[3] Dn[2] Dn[1] Dn[0] RAMRDC 0 ↑ 1 - 0 0 1 1 1 1 1 0 (3Eh) Memory read continue 1 1 ↑ - - - - - - - - - Dummy Read 1 1 ↑ Dx[17:8] Dx[7] Dx[6] Dx[5] Dx[4] Dx[3] Dx[2] Dx[1] Dx[0] 1 1 ↑ Dn[17:8] Dn[7] Dn[6] Dn[5] Dn[4] Dn[3] Dn[2] Dn[1] Dn[0] TESCAN 0 ↑ 1 - 0 1 0 0 0 1 0 0 (44h) Set tear scanline 1 ↑ 1 - N15 N14 N13 N12 N11 N10 N9 N8 1 ↑ 1 - N7 N6 N5 N4 N3 N2 N1 N0 RDTESCAN 0 ↑ 1 - 0 1 0 0 0 1 0 1 (45h) Get scanline 1 1 ↑ - - - - - - - - - Dummy Read 1 1 ↑ - N7 N6 N5 N4 N3 N2 N1 N0 WRDISBV 0 ↑ 1 - 0 1 0 1 0 0 0 1 (51h) Write display brightness 1 ↑ 1 - DBV7 DBV6 DBV5 DBV4 DBV3 DBV2 DBV1 DBV0 RDDISBV 0 ↑ 1 - 0 1 0 1 0 0 1 0 (52h) Read display brightness value 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - DBV7 DBV6 DBV5 DBV4 DBV3 DBV2 DBV1 DBV0 WRCTRLD 0 ↑ 1 - 0 1 0 1 0 0 1 1 (53h) Write CTRL display 1 ↑ 1 - 0 0 BCTRL 0 DD BL 0 0 RDCTRLD 0 ↑ 1 - 0 1 0 1 0 1 0 0 (54h) Read CTRL value dsiplay 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - 0 0 BCTRL 0 DD BL 0 0
Version 1.0 Page 162 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Instruction D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 Hex Function WRCACE 0 ↑ 1 - 0 1 0 1 0 1 0 1 (55h) Write content adaptive brightness control and Color enhancemnet 1 ↑ 1 - CECTRL 0 CE1 CE0 0 0 C1 C0 RDCABC 0 ↑ 1 - 0 1 0 1 0 1 1 0 (56h) Read content adaptive brightness control 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - 0 CECTRL 0 0 0 0 C1 C0 WRCABCMB 0 ↑ 1 - 0 1 0 1 1 1 1 0 (5Eh) Write CABC minimum brightness 1 ↑ 1 - CMB7 CMB6 CMB5 CMB4 CMB3 CMB2 CMB1 CMB0 RDCABCMB 0 ↑ 1 - 0 1 0 1 1 1 1 1 (5Fh) Read CABC minimum brightness 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - CMB7 CMB6 CMB5 CMB4 CMB3 CMB2 CMB1 CMB0 RDABCSDR 0 ↑ 1 - 0 1 1 0 1 0 0 0 (68h) Read Automatic Brightness Control Self-Diagnostic Result 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - D7 D6 0 0 0 0 0 0 - RDID1 0 ↑ 1 - 1 1 0 1 1 0 1 0 (DAh) Read ID1 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - ID17 ID16 ID15 ID14 ID13 ID12 ID11 ID10 Read parameter RDID2 0 ↑ 1 - 1 1 0 1 1 0 1 1 (DBh) Read ID2 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ - ID27 ID26 ID25 ID24 ID23 ID22 ID21 ID20 Read parameter RDID3 0 ↑ 1 - 1 1 0 1 1 1 0 0 (DCh) Read ID3
Version 1.0 Page 163 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Instruction D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 Hex Function 1 1 ↑ - - - - - - - - - Dummy read 1 1 ↑ ID37 ID36 ID35 ID34 ID33 ID32 ID31 ID30 Read parameter Table 19 System Function Command List “-”: Don’t care
Version 1.0 Page 164 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.1 NOP (00h)
00H NOP (No Operation) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX NOP 0 ↑ 1 - 0 0 0 0 0 0 0 0 (00h) Parameter No Parameter - Description This command is empty command. Restriction Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence N/A S/W Reset N/A H/W Reset N/A Flow Chart Note: “-“Don’t care
Version 1.0 Page 165 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.2 SWRESET (01h): Software Reset
01H SWRESET (Software Reset) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX SWRESET 0 ↑ 1 - 0 0 0 0 0 0 0 1 (01h) Parameter No Parameter -
Description
“-“ Don’t care -The display module performs a software reset, registers are written with their SW reset default values. -Frame memory contents are unaffected by this command. Restriction It will be necessary to wait 5msec before sending new command following software reset. The display module loads all display suppliers’ factory default values to the registers during this 5msec. If software reset is sent during sleep in mode, it will be necessary to wait 120msec before sending sleep out command. Software reset command cannot be sent during sleep out sequence. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence N/A S/W Reset N/A H/W Reset N/A
Version 1.0 Page 166 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart SWRESET Set Commands to S/W Default Value Display whole blank screen Sleep In Mode Command Parameter Display Action Mode Legend Sequential transter
Version 1.0 Page 167 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.3 RDDID (04h): Read Display ID
04H RDDID (Read Display ID) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDDID 0 ↑ 1 - 0 0 0 0 0 1 0 0 (04h) 1st parameter 1 1 ↑ - - - - - - - - - - 2nd parameter 1 1 ↑ - ID17 ID16 ID15 ID14 ID13 ID12 ID11 ID10 3rd parameter 1 1 ↑ - ID27 ID26 ID25 ID24 ID23 ID22 ID21 ID20 4th parameter 1 1 ↑ - ID37 ID36 ID35 ID34 ID33 ID32 ID31 ID30 -This read byte returns 24-bit display identification information. -The 1 st parameter is dummy data -The 2 nd parameter (ID17 to ID10): LCD module’s manufacturer ID. -The 3 rd parameter (ID26 to ID20): LCD module/driver version ID -The 4 th parameter (ID37 to UD30): LCD module/driver ID. -Commands RDID1/2/3(Dah, DBh, DCh) read data correspond to the parameters 2,3,4 of the command 04h, respectively. “-“ Don’t care Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value ID1 ID2 ID3 Power On Sequence 0x85 0x85 0x52 S/W Reset 0x85 0x85 0x52 H/W Reset 0x85 0x85 0x52
Version 1.0 Page 168 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart Read 04h Read 04h Dummy Clock Dummy Read Send 2nd parameter Send 2nd parameter Send 3rd parameter Send 3rd parameter Send 4th parameter Send 4th parameter Serial I/F Mode Parallel I/F Mode Host Display Command Parameter Display Action Mode Legend Sequential transter
Version 1.0 Page 169 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.4 RDDST (09h): Read Display Status
09H RDDST (Read Display Status) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDDST 0 ↑ 1 - 0 0 0 0 1 0 0 1 (09h) 1st parameter 1 1 ↑ - - - - - - - - - - 2nd parameter 1 1 ↑ - BSTON MY MX MV ML RGB MH ST24 3rd parameter 1 1 ↑ - ST23 IFPF2 IFPF1 IFPF0 IDMON PTLON SLOUT NORON 4th parameter 1 1 ↑ - ST15 ST14 INVON ST12 ST11 DISON TEON GCS2 5th parameter 1 1 ↑ - GCS1 GCS0 TEM ST4 ST3 ST2 ST1 ST0 This command indicates the current status of the display as described in the table below: Bit Description Value BSTON Booster Voltage Status ‘1’ =Booster on, ‘0’ =Booster off MY Row Address Order (MY) ‘1’ =Decrement, (Bottom t o Top, when MADCTL (36h) D7=’1’) ‘0’ =Increment, (Top to Bottom, when MADCTL (36h) D7=’0’) MX Column Address Order (MX) ‘1’ =Decrement, (Right to Left, when MADCTL (36h) D6=’1’) ‘0’ =Increment, (Left to Right, when MADCTL (36h) D6=’0’) MV Row/Column Exchange (MV) ‘1’ = Row/column exchan ge, (when MADCTL (36h) D5=’1’) ‘0’ = Normal, (when MADCTL (36h) D5=’0’ ML Scan Address Order (ML) ‘0’ =Decrement, (LCD refresh Top to Bottom, when MADCTL (36h) D4=’0’) ‘1’=Increment, (LCD refresh Bottom to Top, when MADCTL (36h) D4=’1’) RGB RGB/ BGR Order (RGB) ‘1’ =BGR, (When MADCTL (36 h) D3=’1’) ‘0’ =RGB, (When MADCTL (36h) D3=’0’) MH Horizontal Order ‘0’ =Decrement, (LCD refresh Left to Right, when MADCTL (36h) D2=’0’) ‘1’ =Increment, (LCD refresh Right to Left, when MADCTL (36h) D2=’1’) ST24 For Future Use ‘0’ ST23 For Future Use ‘0’ IFPF2 Interface Color Pixel Format Definition “011” = 12-bit / pixel, “101” = 16-bit / pixel, “110” = 18-bit / pixel, “111” = 16M truncated, others are not defined. IFPF1 IFPF0 IDMON Idle Mode On/Off ‘1’ = On, “0” = Off PTLON Partial Mode On/Off ‘1’ = On, “0” = Off
Version 1.0 Page 170 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. SLPOUT Sleep In/Out ‘1’ = Out, “0” = In NORON Display Normal Mode On/Off ‘1’ = Normal Display, ‘0’ = Partial Display ST15 Vertical Scrolling Status (Not Used) ‘1’ = Scroll on,“0” = Scroll off ST14 Horizontal Scroll Status (Not Used) ‘0’ INVON Inversion Status ‘1’ = On, “0” = Off ST12 All Pixels On (Not Used) ‘0’ ST11 All Pixels Off (Not Used) ‘0’ DISON Display On/Of f ‘1’ = On, “0” = Off TEON Tearing effect line on/off ‘1’ = On, “0” = Off GCSEL2 Gamma Curve Selection “000” = GC0 “001” = GC1 “010” = GC2 “011” = GC3 ”100” to “111” = Not defined GCSEL1 GCSEL0 TEM Tearing effect line mode ‘0’ = mode1, ‘1’ = mode2 ST4 For Future Use ‘0’ ST3 For Future Use ‘0’ ST2 For Future Use ‘0’ ST1 For Future Use ‘0’ ST0 For Future Use ‘0’ “-“ Don’t care Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value (ST31 to ST0) Power On Sequence 0000-0000 0110-0001 0000-0000 000 0-0000 S/W Reset 0xxx-xx00 0xxx-0001 0000-0000 0000-0000 H/W Reset 0000-0000 0110-0001 0000-0000 0000-0000
Version 1.0 Page 171 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart
Version 1.0 Page 172 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.5 RDDPM (0Ah): Read Display Power Mode
0AH RDDPM (Read Display Power Mode) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDDPM 0 ↑ 1 - 0 0 0 0 1 0 1 0 (0Ah) 1st parameter 1 1 ↑ - - - - - - - - - - 2nd parameter 1 1 ↑ - BSTON IDMON PTLON SLPOUT NORON DISON D1 D0 This command indicates the current status of the display as described in the table below: Bit Description Value BSTON Booster Voltage Status ‘1’ =Booster on, ‘0’ =Booster off IDMON Idle mode on/off ‘1’ = Idle Mode On, ‘0’ = Idle Mode Off PTLON Partial mode on/off ‘1’ =Partial mode on, ‘0’ =Partial mode off, SLPOUT Sleep in/out ‘1’ =Sleep out, ‘0’ =Sleep in, NORON Display normal mode on/off ‘1’ = Normal displ ay, ‘0’ = Partial display, DISON Display on/off ‘1’ =Display on, ‘0’ =Display off, D1 Not Used “0” D0 Not Used “0” “-“ Don’t care Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes
Version 1.0 Page 173 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Default Status Default Value (D7 to D0) Power On Sequence 0000-1000(08h) S/W Reset 0000-1000(08h) H/W Reset 0000-1000(08h) Flow Chart
Version 1.0 Page 174 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.6 RDDMADCTL (0Bh): Read Display MADCTL
0BH RDDMADCTL (Read Display MADCTL) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDDMADCTL 0 ↑ 1 - 0 0 0 0 1 0 1 1 (0Bh) 1st parameter 1 1 ↑ - - - - - - - - - - 2nd parameter 1 1 ↑ - MY MX MV ML RGB MH D1 D0 This command indicates the current status of the display as described in the table below: Bit Description Value MY Row Address Order (MY) ‘1’ =Decrement, (Bottom t o Top, when MADCTL (36h) D7=’1’) ‘0’ =Increment, (Top to Bottom, when MADCTL (36h) D7=’0’) MX Column Address Order (MX) ‘1’ =Decrement, (Right to Left, when MADCTL (36h) D6=’1’) ‘0’ =Increment, (Left to Right, when MADCTL (36h) D6=’1’) MV Row/Column Exchange (MV) ‘1’ = Row/column exchan ge, (when MADCTL (36h) D5=’1’) ‘0’ = Normal, (when MADCTL (36h) D5=’0’ ML Scan Address Order (ML) ‘0’ =Decrement, (LCD refresh Top to Bottom, when MADCTL (36h) D4=’0’) ‘1’=Increment, (LCD refresh Bottom to Top, when MADCTL (36h) D4=’1’) RGB RGB/ BGR Order (RGB) ‘1’ =BGR, (When MADCTL (36 h) D3=’1’) ‘0’ =RGB, (When MADCTL (36h) D3=’0’) MH Horizontal Order ‘0’ =Decrement, (LCD refresh Left to Right, when MADCTL (36h) D2=’0’) ‘1’ =Increment, (LCD refresh Right to Left, when MADCTL (36h) D2=’1’) D1 Not used ‘0’ D0 Not used ‘0’ “-“ Don’t care Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes
Version 1.0 Page 175 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Default Status Default Value (D7 to D0) Power On Sequence 0000-0000 (00h) S/W Reset No change H/W Reset 0000-0000 (00h) Flow Chart
Version 1.0 Page 176 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.7 RDDCOLMOD (0Ch): Read Display Pixel Format
0CH RDDCOLMOD (Read Display Pixel Format) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDDCOLMOD 0 ↑ 1 - 0 0 0 0 1 1 0 0 (0Ch) 1st parameter 1 1 ↑ - - - - - - - - - - 2nd parameter 1 1 ↑ - 0 D6 D5 D4 0 D2 D1 D0 This command indicates the current status of the display as described in the table below: Bit Description Value D7 - Set to ‘0’ RGB interface color format ‘101’ = 16 bit/pixel ‘110’ = 18 bit/pixel D3 - Set to ‘0’ Control interface color format ‘101’ = 16 bit/pixel ‘110’ = 18 bit/pixel Others are no define and invalid “-“ Don’t care Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000-0110 (18 bit/pixel) S/W Reset No change H/W Reset 0000-0110 (18 bit/pixel)
Version 1.0 Page 177 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart
Version 1.0 Page 178 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.8 RDDIM (0Dh): Read Display Image Mode
0DH RDDIM (Read Display Image Mode) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDDIM 0 ↑ 1 - 0 0 0 0 1 1 0 1 (0Dh) 1st parameter 1 1 ↑ - - - - - - - - - - 2nd parameter 1 1 ↑ - VSSON 0 INVON 0 0 GC2 GC1 GC0 This command indicates the current status of the display as described in the table below: -VSSON: Vertical scrolling on/off -INVON: Inversion on/off Gamma Curve Selection GC2 GC1 GC0 Gamma set (26h) Parameter Gamma curve 1 0 0 0 GC0 Gamma curve 2 0 0 1 GC1 Gamma curve 3 0 1 0 GC2 Gamma curve 4 0 1 1 GC3 Not Defined 1 0 0 Not Defined Not Defined 1 0 1 Not Defined Not Defined 1 1 0 Not Defined Not Defined 1 1 1 Not Defined Others are no define and invalid “-“ Don’t care Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000-0000 S/W Reset 0000-0000
Version 1.0 Page 179 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. H/W Reset 0000-0000 Flow Chart
Version 1.0 Page 180 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.9 RDDSM (0Eh): Read Display Signal Mode
0EH RDDSM (Read Display Signal Status) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDDSM 0 ↑ 1 - 0 0 0 0 1 1 1 0 (0Eh) 1st parameter 1 1 ↑ - - - - - - - - - - 2nd parameter 1 1 ↑ - TEON TEM 0 0 0 0 0 0 - This command indicates the current status of the display as described in the table below: Bit Description Value TEON Tearing effect line on/off ‘1’ = ON, ‘0’ = OFF, TEM Tearing effect line mode ‘1’ = mode2, ‘0’ = mode1, “-“ Don’t care Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000-0000 S/W Reset 0000-0000 H/W Reset 0000-0000
Version 1.0 Page 181 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart
Version 1.0 Page 182 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.10 RDDSDR (0Fh): Read Display Self-Diagnostic Result
09H RDDSDR (Read Display Self-Diagnostic Result) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDDSDR 0 ↑ 1 - 0 0 0 0 1 1 1 1 (0Fh) 1st parameter 1 1 ↑ - - - - - - - - - - 2nd parameter 1 1 ↑ - D7 D6 0 0 0 0 0 0 - This command indicates the current status of the display self-diagnostic result after sleep out command as described below: -D7: Register loading detection -D6: Functionality detection “-“ Don’t care Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000-0000 S/W Reset 0000-0000 H/W Reset 0000-0000
Version 1.0 Page 183 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart
Version 1.0 Page 184 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.11 SLPIN (10h): Sleep in
10H SLPIN (Sleep In) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX SLPIN 0 ↑ 1 - 0 0 0 1 0 0 0 0 (10h) parameter No Parameter -This command causes the LCD module to enter the minimum power consumption mode. -In this mode the DC/DC converter is stopped, internal oscillator is stopped, and panel scanning is stopped. -MCU interface and memory are still working and the memory keeps its contents. “-“ Don’t care Restriction -This command has no effect when module is already in sleep in mode. Sleep in mode can only be left by the sleep out command (11h). -It will be necess ary to wait 5msec before sending any new commands to a display module following this command to allow time for the supply voltages and clock circuits to stabilize. -It will be necessary to wait 120msec after sending sleep out command (when in sleep in mode ) before sending an sleep in command. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Sleep in mode S/W Reset Sleep in mode H/W Reset Sleep in mode
Version 1.0 Page 185 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart SLPIN Display whole blank screen (Automatic No effect to DISP ON/OFF Commands) Drain Charge From LCD Panel Stop DC”DC Converter Stop Internal Oscillator Sleep In Mode Command Parameter Display Action Mode Legend Sequential transter
Version 1.0 Page 186 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.12 SLPOUT (11h): Sleep Out
11H SLPOUT (Sleep Out) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX SLPOUT 0 ↑ 1 - 0 0 0 1 0 0 0 1 (11h) parameter No Parameter -This command turn off sleep mode. -In this mode the DC/DC converter is enable, internal display oscillator is started, and panel scanning is started. Restriction -This command has no effect when module is already in sleep out mode. Sleep out mode can only be left by the sleep in command (10h). -It will be necessary to wait 5msec before sending any new commands to a display module following this c ommand to allow time for the supply voltages and clock circuits to stabilize. -It will be necessary to wait 120msec after sending sleep out command (when in sleep in mode) before sending an sleep in command. -The display module runs the self-diagnostic functions after this command is received. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Sleep in mode S/W Reset Sleep in mode H/W Reset Sleep in mode
Version 1.0 Page 187 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart SLPOUT Start Internal Oscillator Start up DC:DC Converter Display whole blank screen for 2 firames (Automatic No effect to DISP ON/OFF Commands) Display Memory contents In accordance with the current command table settings Sleep Out mode Charge Offset voltage for LCD Panel Command Parameter Display Action Mode Legend Sequential transter
Version 1.0 Page 188 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.13 PTLON (12h): Partial Display Mode On
12H PTLON (Partial Display Mode On) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX PTLON 0 ↑ 1 - 0 0 0 1 0 0 1 0 (12h) parameter No Parameter -This command turns on Partial mode. The partial mode window is described by the Partial Area command (30h) -To leave Partial mode, the Normal Display Mode On command (13h) should be written. “-“ Don’t care Restriction This command has no effect when partial mode is active. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Normal display mode on S/W Reset Normal display mode on H/W Reset Normal display mode on Flow Chart See Partial Area (30h)
Version 1.0 Page 189 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.14 NORON (13h): Normal Display Mode On
12H NORON (Normal Display Mode On) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX NORON 0 ↑ 1 - 0 0 0 1 0 0 1 1 (13h) parameter No Parameter -This command turns the display to normal mode. -Normal display mode on means partial mode off. -Exit from NORON by the partial mode on command. “-“ Don’t care Restriction This command has no effect when normal display mode is active. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Normal display mode on S/W Reset Normal display mode on H/W Reset Normal display mode on Flow Chart See partial area description for details of when to use this command.
Version 1.0 Page 190 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.15 INVOFF (20h): Display Inversion Off
20H INVOFF (Display Inversion Off) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX INVOFF 0 ↑ 1 - 0 0 1 0 0 0 0 0 (20h) parameter No Parameter -This command is used to recover from display inversion mode. “-“ Don’t care Restriction This command has no effect when module is already in inversion off mode. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Display inversion off S/W Reset Display inversion off H/W Reset Display inversion off T op-Lef t (0,0) (Example) Memory Display
Version 1.0 Page 191 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart INVOFF (20h) Command Parameter Display Action Mode Legend Sequential transter Display Inversion On Mode Display Inversion OFF Mode
Version 1.0 Page 192 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.16 INVON (21h): Display Inversion On
21H INVON (Display Inversion On) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX INVON 0 ↑ 1 - 0 0 1 0 0 0 0 1 (21h) parameter No Parameter -This command is used to recover from display inversion mode. “-“ Don’t care Restriction This command has no effect when module is already in inversion on mode. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Display inversion off S/W Reset Display inversion off H/W Reset Display inversion off T op-Left (0,0) (Example) Memory Display
Version 1.0 Page 193 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart INVON (21h) Command Parameter Display Action Mode Legend Sequential transter Display Inversion OFF Mode Display Inversion ON Mode
Version 1.0 Page 194 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.17 GAMSET (26h): Gamma Set
26H GAMSET (Gamma Set) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX GAMSET 0 ↑ 1 - 0 0 1 0 0 1 1 0 (26h) parameter 1 ↑ 1 - 0 0 0 0 GC3 GC2 GC1 GC0 1. Description -This command is used to select the desired Gamma curve for the current display. A maximum of 4 curves can be selected. The curve is selected by setting the appropriate bit in the parameter as described in the Table. GC [7:0] Parameter Curve Selected 01h GC0 Gamma Curve 1 (G2.2) 02h GC1 Gamma Curve 2 (G1.8) 04h GC2 Gamma Curve 3 (G2.5) 08h GC3 Gamma Curve 4 (G1.0) Note: All other values are undefined. Restriction Values of GC[7:0] not shown in table above are invalid and will not change the current selected Gamma curve until valid value is received. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0x01 S/W Reset 0x01 H/W Reset 0x01
Version 1.0 Page 195 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart
Version 1.0 Page 196 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.18 DISPOFF (28h): Display Off
28H DISPOFF (Display Off) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX DISPOFF 0 ↑ 1 - 0 0 1 0 1 0 0 0 (28h) parameter No Parameter
- This command is used to enter into DISPLAY OFF mode. In this mode, the output from Frame Memory is disabled and blank page inserted. - This command makes no change of contents of frame memory. - This command does not change any other status. - There will be no abnormal visible effect on the display. - Exit from this command by Display On (29h) Restriction This command has no effect when module is already in display off mode. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Display off S/W Reset Display off H/W Reset Display off (Example) Memory Display
Version 1.0 Page 197 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart
Version 1.0 Page 198 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. (Example) Memory Display
9.1.19 DISPON (29h): Display On
29H DISPON (Display On) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX DISPON 0 ↑ 1 - 0 0 1 0 1 0 0 1 (29h) parameter No Parameter
- This command is used to recover from DISPLAY OFF mode. - Output from the Frame Memory is enabled. - This command makes no change of contents of frame memory. - This command does not change any other status. Restriction This command has no effect when module is already in display on mode. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Display off S/W Reset Display off H/W Reset Display off
Version 1.0 Page 199 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart Display Off Mode DISPON Display On Mode Command Parameter Display Action Mode Legend Sequential transter
Version 1.0 Page 200 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.20 CASET (2Ah): Column Address Set
2AH CASET (Column Address Set) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX CASET 0 ↑ 1 - 0 0 1 0 1 0 1 0 (2Ah) 1st parameter 1 ↑ 1 - XS15 XS14 XS13 XS12 XS11 XS10 XS9 XS8 2nd parameter 1 ↑ 1 - XS7 XS6 XS5 XS4 XS3 XS2 XS1 XS0 3rd parameter 1 ↑ 1 - XE15 XE14 XE13 XE12 XE11 XE10 XE9 XE8 4th parameter 1 ↑ 1 - XE7 XE6 XE5 XE4 XE3 XE2 XE1 XE0 2. Description -The value of XS [7:0] and XE [7:0] are referred when RAMWR command comes. -Each value represents one column line in the Frame Memory. XS[7:0] XE[7:0] Restriction XS [15:0] always must be equal to or less than XE [15:0] When XS [15:0] or XE [15:0] is greater than maximum address like below, data of out of range will be ignored. (Parameter range: 0 < XS [15:0] < XE [15:0] < 239 (00Efh)): MV=”0”) (Parameter range: 0 < XS [15:0] < XE [15:0] < 319 (013Fh)): MV=”1”) Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence XS[15:0]=0x00 XE[15:0]=0xEF S/W Reset XS[15:0]=0x00 When MV=0: XE[15:0]=00Efh, When MV=1: XE[15:0]=013Fh H/W Reset XS[15:0]=0x00 XE[15:0]=0xEF
Version 1.0 Page 201 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart
Version 1.0 Page 202 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.21 RASET (2Bh): Row Address Set
2BH RASET (Row Address Set) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RASET 0 ↑ 1 - 0 0 1 0 1 0 1 1 (2Bh) 1st parameter 1 ↑ 1 - YS15 YS14 YS13 YS12 YS11 YS10 YS9 YS8 2nd parameter 1 ↑ 1 - YS7 YS6 YS5 YS4 YS3 YS2 YS1 YS0 3rd parameter 1 ↑ 1 - YE15 YE14 YE13 YE12 YE11 YE10 YE9 YE8 4th parameter 1 ↑ 1 - YE7 YE6 YE5 YE4 YE3 YE2 YE1 YE0 3. Description -This command is used to defined area of frame memory where MCU can access. -The value of YS [15:0] and YE [15:0] are referred when RAMWR command comes. -Each value represents one page line in the Frame Memory. Restriction YS [15:0] always must be equal to or less than YE [15:0] When YS [15:0] or YE [15:0] is greater than maximum address like below, data of out of range will be ignored. (Parameter range: 0 < YS [15:0] < YE [15:0] < 319 (013fh)): MV=”0”) (Parameter range: 0 < YS [15:0] < YE [15:0] < 239 (00EFh)): MV=”1”) Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence YS[15:0]=0000h YE[15:0]=013Fh S/W Reset YS[15:0]=0000h When MV=0: YE[15:0]=013Fh, When MV=1: YE[15:0]=00Efh H/W Reset YS[15:0]=0000h YE[15:0]=013Fh YS[15:0] YE[15:0]
Version 1.0 Page 203 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart CASET 1st parameter XS[15:0] 2nd parameter XE[15:0] PASET 1st parameter YS[15:0] 2nd parameter YE[15:0] RAMWR Image Data D1[7:0],D2[7:0] …….Dn[7:0] Any Command Command Parameter Display Action Mode Legend Sequential transter
Version 1.0 Page 204 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.22 RAMWR (2Ch): Memory Write
2CH RAMWR (Memory Write) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RAMWR 0 ↑ 1 - 0 0 1 0 1 1 0 0 (2Ch) 1st parameter 1 ↑ 1 D1[17]-1[8] D1[7] D1[6] D1[5] D1[4] D1[3] D1[2] D1[1] D1[0] … 1 ↑ 1 Dx[17]-x[8] Dx[7] Dx[6] Dx[5] Dx[4] Dx[3] Dx[2] Dx[1] Dx[0] N parameter 1 ↑ 1 Dn[17]-n[8] Dn[7] Dn[6] Dn[5] Dn[4] Dn[3] Dn[2] Dn[1] Dn[0] -This command is used to transfer data from MCU to frame memory. -When this command is accepted, the column register and the page register are reset to the start column/start page positions. -The start column/start page positions are different in accordance with MADCTL setting. -Sending any other command can stop frame write. Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Contents of memory is set randoml y S/W Reset Contents of memory is not cleared H/W Reset Contents of memory is not cleared
Version 1.0 Page 205 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart Command Parameter Display Action Mode Legend Sequential transter RAMWR Image Data D1[17:0],D2[17:0] …….Dn[17:0] Any Command
Version 1.0 Page 206 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.23 RAMRD (2Eh): Memory Read
2EH RAMRD (Memory Read) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RAMRD 0 ↑ 1 - 0 0 1 0 1 1 1 0 (2Eh) 1st parameter 1 1 ↑ - - - - - - - - - 2nd parameter 1 1 ↑ D17-8 D7 D6 D5 D4 D3 D2 D1 D0 .. 1 1 ↑ (N+1) th parameter 1 1 ↑ D17-8 D7 D6 D5 D4 D3 D2 D1 D0 -This command is used to transfer data from frame memory to MCU. -When this command is accepted, the column register and the row register are reset to the Start Column/Start Row positions. -The Start Column/Start Row positions are different in accordance with MADCTL setting. -Then D[17:0] is read back from the frame memory and the column register and the row register incremented -Frame Read can be cancelled by sending any other command. -The data color coding is fixed to 18-bit in reading function. Please see section 9.8 “Data color coding” for color coding (18-bit cases), when there is used 8, 9, 16 and 18-bit data lines for image data. Note1: The Command 3Ah should be set to 66h when reading pixel data from frame memory. Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Contents of memory is set randoml y S/W Reset Contents of memory is not cleared H/W Reset Contents of memory is not cleared
Version 1.0 Page 207 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart
Version 1.0 Page 208 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.24 PTLAR (30h): Partial Area
30H PTLAR (Partial Area) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX PTLAR 0 ↑ 1 - 0 0 1 1 0 0 0 0 (30h) 1st parameter 1 ↑ 1 - PSL15 PSL14 PSL13 PSL12 PSL11 PSL10 PSL9 PSL8 2nd parameter 1 ↑ 1 - PSL7 PSL6 PSL5 PSL4 PSL3 PSL2 PSL1 PSL0 3rd parameter 1 ↑ 1 - PEL15 PEL14 PEL13 PEL12 PEL11 PEL10 PEL9 PEL8 4th parameter 1 ↑ 1 - PEL7 PEL6 PEL5 PEL4 PEL3 PEL2 PEL1 PEL0 -This command defines the partial mode’s display area. -There are 4 parameters associated with this command, the first defines the Start Row (PSL) and the second the End Row (PEL), as illustrated in the figures below. PSL and PEL refer to the Frame Memory row address counter. -If End Row > Start Row, when MADCTL ML=’1’ -If End Row > Start Row, when MADCTL ML=’0’ -If End Row < Start Row, when MADCTL ML=’0’ Non-display area Non-display area Partial display area PSL [15:0] PEL [15:0] End row Non-display area Non-display area Partial display area PSL [15:0] PEL [15:0] Start row Partial display area PSL [15:0] PEL [15:0] Start row End row Non-display area Partial display area Start row End row
Version 1.0 Page 209 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. -If End Row = Start Row then the Partial Area will be one row deep. Restriction Each detail initial value by the display resolution will be updated. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence PSL[15:0]=0000h, PEL=013Fh S/W Reset PSL[15:0]=0000h, PEL=013Fh H/W Reset PSL[15:0]=0000h, PEL=013Fh Flow Chart
Version 1.0 Page 210 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.25 VSCRDEF (33h): Vertical Scrolling Definition
33H (Vertical Scrolling Definition) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX VSCRDEF 0 ↑ 1 - 0 0 1 1 0 0 1 1 (33h) 1st parameter 1 ↑ 1 - TFA15 TFA14 TFA13 TFA12 TFA11 TFA10 TFA9 TFA8 2nd parameter 1 ↑ 1 - TFA7 TFA6 TFA5 TFA4 TFA3 TFA2 TFA1 TFA0 3rd parameter 1 ↑ 1 - VSA15 VSA14 VSA13 VSA12 VSA11 VSA10 VSA9 VSA8 4th parameter 1 ↑ 1 - VSA7 VSA6 VSA5 VSA4 VSA3 VSA2 VSA1 VSA0 5th parameter 1 ↑ 1 BFA15 BFA14 BFA13 BFA12 BFA11 BFA10 BFA9 BFA8 6th parameter 1 ↑ 1 BFA7 BFA6 BFA5 BFA4 BFA3 BFA2 BFA1 BFA0 -This command just defines the Vertical Scrolling Area of the display and not performs vertical scroll -When MADCTL MV=0 -The 1 st & 2 nd parameter TFA [15:0] describes the Top Fixed Area (in No. of lines from Top of the Frame Memory and Display). -The 3 rd & 4 th parameter VSA [15:0] describes the height of the Vertical Scrolling Area (in No. of lines of the Frame Memory [not the display] from the Vertical Scrolling Start Address) The first line appears immediately after the bottom most line of the Top Fixed Area. -The 4 th & 5 th parameter BFA [6:0] describes the Bottom Fixed Area (in No. of lines from Bottom of the Frame Memory and Display). TFA, VSA and BFA refer to the Frame Memory Line Pointer Restriction The condition is TFA+VSA+BFA = 320, otherwise Scrolling mode is undefined.
Version 1.0 Page 211 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. In Vertical Scrolling Mode, MADCTL parameter MV should be set to ‘0’ – this only affects the Frame Memory write. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence TFA[15:0] = 0000h VSA[0:15] = 014 0h BFA[15:0] = 0000h S/W Reset TFA[15:0] = 0000h VSA[0:15] = 0140h BFA[1 5:0] = 0000h H/W Reset TFA[15:0] = 0000h VSA[0:15] = 0140h BFA[1 5:0] = 0000h
Version 1.0 Page 212 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart 1. TO Enter Vertical Scroll Mode: Command Parameter Display Action Mode Legend Sequential transter Normal Mode VSCRDEF 1st parameter TFA[15:0] 2nd parameter VSA[15:0] 3rd parameter BFA[15:0] CASET 1st &2nd parameter XS[15:0] 3rd & 4th parameter XE[15:0] RASET MADCTL Parameter RAMWR Scroll Image Data VSCSAD 1st &2nd parameter VSA[15:0] Scroll Mode 1st &2nd parameter YS[15:0] 3rd &4th parameter YE[15:0] Only required for non”rolling scrolling Redefines the Frame Memory Window that the scroll data will be written to. Optional ” It may be necessary to redefine the frame memory write direction.
Version 1.0 Page 213 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.26 TEOFF (34h): Tearing Effect Line OFF
34H TEOFF (Tearing Effect Line OFF) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX TEOFF 0 ↑ 1 - 0 0 1 1 0 1 0 0 (34h) parameter No Parameter Description -This command is used to turn OFF (Active Low) the Tearing Effect output signal from the TE signal line. Restriction This command has no effect when tearing effect output is already off.. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Off S/W Reset Off H/W Reset Off
Version 1.0 Page 214 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart TE Line Output ON TEOFF TE Line Output OFF Command Parameter Display Action Mode Legend Sequential transter
Version 1.0 Page 215 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.27 TEON (35h): Tearing Effect Line On
35H TEON (Tearing Effect Line On) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX TEON 0 ↑ 1 - 0 0 1 1 0 1 0 1 (35h) parameter 1 ↑ 1 - 0 0 0 0 0 0 0 TEM -This command is used to turn ON the Tearing Effect output signal from the TE signal line. -This output is not affected by changing MADCTL bit ML. -The Tearing Effect Line On has one parameter, which describes the mode of the Tearing Effect Output Line: -When TEM =’0’: The Tearing Effect output line consists of V-Blanking information only Tvdl Tvdh Vertical time scale -When TEM =’1’: The Tearing Effect output Line consists of both V-Blanking and H-Blanking information Tvdl Tvdh Vertical time scale Note: During Sleep In Mode with Tearing Effect Line On, Tearing Effect Output pin will be active Low. Restriction This command has no effect when tearing effect output is already on. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Off S/W Reset Off H/W Reset Off
Version 1.0 Page 216 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart Command Parameter Display Action Mode Legend Sequential transter TE Line Output OFF TEON TE Line Output ON TELOM
Version 1.0 Page 217 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.28 MADCTL (36h): Memory Data Access Control
36H MADCTL (Memory Data Access Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX MADCTL 0 ↑ 1 - 0 0 1 1 0 1 1 0 (36h) parameter 1 ↑ 1 - MY MX MV ML RGB MH - - -This command defines read/ write scanning direction of frame memory. -Bit Assignment Bit D7- Page Address Order “0” = Top to Bottom (When MADCTL D7=”0”). “1” = Bottom to Top (When MADCTL D7=”1”). Bit D6- Column Address Order “0” = Left to Right (When MADCTL D6=”0”). “1” = Right to Left (When MADCTL D6=”1”). Bit D5- Page/Column Order “0” = Normal Mode (When MADCTL D5=”0”). “1” = Reverse Mode (When MADCTL D5=”1”) Note: Bits D7 to D5, alse refer to section 8.12 Address Control Bit D4- Line Address Order “0” = LCD Refresh Top to Bottom (When MADCTL D4=”0”) “1” = LCD Refresh Bottom to Top (When MADCTL D4=”1”) Bit D3- RGB/BGR Order “0” = RGB (When MADCTL D3=”0”) “1” = BGR (When MADCTL D3=”1”) Bit D2- Display Data Latch Data Order “0” = LCD Refresh Left to Right (When MADCTL D2=”0”) “1” = LCD Refresh Right to Left (When MADCTL D2=”1”) Bit NAME DESCRIPTION D7 MY Page Address Order D6 MX Column Address Order D5 MV Page/Column Order D4 ML Line Address Order D3 RGB RGB/BGR Order D2 MH Display Data Latch Order
Version 1.0 Page 218 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Memory Display Top-left (0, 0) MH="0" Memory Display Top-left (0, 0) Top-left (0, 0) Top-left (0, 0) MH="1" Sent First Sent 2nd Sent 3rd Sent Last Sent First Sent 2nd Sent 3rd Sent Last Restriction Register R G B R G B R G B SIG1 SIG2 SIG240 Driver IC RGB="0" R G B R G B R G B SIG1 SIG2 SIG240 Driver IC RGB="1" R G B R G B SIG1 R G B R G B SIG2 R G B R G B SIG240 R GB R GB SIG1 RGB RGB SIG2 RGB RGB SIG240 LCD panel LCD panel
Version 1.0 Page 219 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000h S/W Reset No change H/W Reset 0000h Flow Chart Command Parameter Display Action Mode Legend Sequential transter MADCTL 1st parameter B[7:0]
Version 1.0 Page 220 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.29 VSCSAD (37h): Vertical Scroll Start Address of RAM
37H VSCSAD (Vertical Scroll Start Address of RAM) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX VSCSAD 0 ↑ 1 - 0 0 1 1 0 1 1 1 (37h) 1ST parameter 1 ↑ 1 - VSP15 VSP14 VSP13 VSP12 VSP11 VSP10 VSP9 VSP8 2ND parameter 1 ↑ 1 - VSP7 VSP6 VSP5 VSP4 VSP3 VSP2 VSP1 VSP0 -This command is used together with Vertical Scrolling Definition (33h). -These two commands describe the scrolling area and the scrolling mode. -The Vertical Scrolling Start Address command has one parameter which describes which line in the Frame Memory will be written as the first line after the last line of the Top Fixed Area on the display as illustrated below: When ML=0 Example: When Top Fixed Area = Bottom Fixed Area = 00, vertical Scrolling Area = 320 and VSP = ‘3’ When ML=1 Example: When Top Fixed Area = Bottom Fixed Area = 00, vertical Scrolling Area = 320 and VSP = ‘3’ NOTE: When new Pointer position and Picture Data are sent, the result on the display will happen at the next Panel Scan to avoid tearing effect. VSP refers to the Frame Memory line Pointer Restriction Since the value of the vertical scrolling start address is absolute (with reference to the frame memory), it must not enter the fixed area (defined by Vertical Scrolling Definition (33h)- otherwise undesirable image will be displayed on the panel) Register
Version 1.0 Page 221 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000h S/W Reset 0000h H/W Reset 0000h Flow Chart See Vertical Scrolling Definition (33h) description
Version 1.0 Page 222 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.30 IDMOFF (38h): Idle Mode Off
38H IDMOFF (Idle Mode Off) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX IDMOFF 0 ↑ 1 - 0 0 1 1 1 0 0 0 (38h) parameter No Parameter -This command is used to recover from Idle mode on. -In the idle off mode, 1. LCD can display 4096, 65k or 262k colors. 2. Normal frame frequency is applied. Restriction This command has no effect when module is already in idle off mode Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Idle mode off S/W Reset Idle mode off H/W Reset Idle mode off
Version 1.0 Page 223 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart
Version 1.0 Page 224 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.31 IDMON (39h): Idle mode on
39H IDMON (Idle Mode On) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX IDMON 0 ↑ 1 - 0 0 1 1 1 0 0 1 (39h) parameter No Parameter -This command is used to enter into Idle mode on. -There will be no abnormal visible effect on the display mode change transition. -In the idle on mode, 1. Color expression is reduced. The primary and the secondary colors using MSB of each R,G and B in the Frame Memory, 8 color depth data is displayed. 2. 8-Color mode frame frequency is applied. 3. Exit from IDMON by Idle Mode Off (38h) command Color R5 R4 R3 R2 R1 G5 G4 G3 G2 G1 B5 B4 B3 B4 B1 Black 0xxxxx 0xxxxx 0xxxxx Blue 0xxxxx 0xxxxx 1xxxxx Red 1xxxxx 0xxxxx 0xxxxx Magenta 1xxxxx 0xxxxx 1xxxxx Green 0xxxxx 1xxxxx 0xxxxx Cyan 0xxxxx 1xxxxx 1xxxxx Yellow 1xxxxx 1xxxxx 0xxxxx White 1xxxxx 1xxxxx 1xxxxx Restriction This command has no effect when module is already in idle off mode Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Top-Left (0,0) (Example) Memory Display
Version 1.0 Page 225 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Default Status Default Value Power On Sequence Idle mode off S/W Reset Idle mode off H/W Reset Idle mode off Flow Chart Command Parameter Display Action Mode Legend Sequential transter Idle off mode IDMON Idle on mode
Version 1.0 Page 226 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.32 COLMOD (3Ah): Interface Pixel Format
3AH COLMOD (Interface Pixel Format) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX COLMOD 0 ↑ 1 - 0 0 1 1 1 0 1 0 (3Ah) 1st Parameter 1 ↑ 1 - 0 D6 D5 D4 0 D2 D1 D0 This command is used to define the format of RGB picture data, which is to be transferred via the MCU interface. The formats are shown in the table: st parameter: Bit Description D7 - Set to ‘0’ RGB interface color format ‘101’ = 65K of RGB interface ‘110’ = 262K of RGB interface D3 - Set to ‘0’ Control interface color format ‘011’ = 12bit/pixel ‘101’ = 16bit/pixel ‘110’ = 18bit/pixel ‘111’ = 16M truncated Note1: In 12-bit/Pixel, 16-bit/Pixel or 18-bit/Pixel mode, the LUT is applied to transfer data into the Frame Memory. Note2: The Command 3Ah should be set at 55h when writing 16-bit/pixel data into frame memory, but 3Ah should be re-set to 66h when reading pixel data from frame memory. Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 18bit/pixel S/W Reset No change H/W Reset 18bit/pixel Flow Chart See Vertical Scrolling Definition (33h) description
Version 1.0 Page 227 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.33 WRMEMC (3Ch): Write Memory Continue
3CH WRMEMC (Write Memory Continue) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX WRMEMC 0 ↑ 1 - 0 0 1 1 1 1 0 0 (3Ch) 1ST parameter 1 ↑ 1 D1[17]-D1[8] D1[7] D1[6] D1[5] D1[4] D1[3] D1[2] D1[1] D1[0] … 1 ↑ 1 Dx[17]-Dx[8] Dx[7] Dx[6] Dx[5] Dx[4] Dx[3] Dx[2] Dx[1] Dx[0] N th parameter 1 ↑ 1 Dn[17]-Dn[8] Dn[7] Dn[6] Dn[5] Dn[4] Dn[3] Dn[2] Dn[1] Dn[0] -This command transfers image data from the host processor to the display module’s frame memory continuing from the pixel location following the previous write memory continue or memory write command. -If MV=0: Data is written continuing from the pixel location after the write range of the previous memory write or write memory continue. The column register is then incremented and pixels are written to the frame memory until the column register equals the end column (XE) value. The colu mn register is then reset to XS and the page register is incremented. Pixels are written to the frame memory until the page register equals the end page (YE) value and the column register equals the XE value, or the host processor sends another command. If the number of pixels exceeds (XE-XS+1)*(YE-YS+1) the extra pixels are ignored. If MV=1: Data is written continuing from the pixel location after the write range of the previous memory write or write memory continue. The page register is then incremented and pixels are written to the frame memory until the page register equals the end page (YE) value. The page register is then reset to YS and the column register is incremented. Pixels are written to the frame memory until the column register equals the end column (XE) value and the page register equals the YE value, or the host processor sends another command. If the number of pixels exceeds (XE-XS+1)*(YE-YS+1) the extra pixels are ignored. Restriction A memory write should follow a column address set or page address set to define the write address. Otherwise, data written with write memory continue is written to undefined addresses. Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes
Version 1.0 Page 228 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Default Status Default Value Power On Sequence Contents of memory is set randoml y S/W Reset Contents of memory is not cleared H/W Reset Contents of memory is not cleared Flow Chart Command Parameter Display Action Mode Legend Sequential transter WRMEMC Image Data D1[17:0],D2[17:0] …….Dn[17:0] Any Command
Version 1.0 Page 229 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.34 RDMEMC (3Eh): Read Memory Continue
3EH RDMEMC (Read Memory Continue) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDMEMC 0 ↑ 1 - 0 0 1 1 1 1 1 0 (3Eh) 1ST parameter 1 1 ↑ - - - - - - - - - 2nd parameter 1 1 ↑ D1[17]-D1[8] D1[7] D1[6] D1[5] D1[4] D1[3] D1[2] D1[1] D1[0] … 1 1 ↑ Dx[17]-Dx[8] Dx[7] Dx[6] Dx[5] Dx[4] Dx[3] Dx[2] Dx[1] Dx[0] N th parameter 1 1 ↑ Dn[17]-Dn[8] Dn[7] Dn[6] Dn[5] Dn[4] Dn[3] Dn[2] Dn[1] Dn[0] -This command transfers image data from the host processor to the display module’s frame memory continuing from the pixel location following the previous read memory continue or memory read command. -If MV=0: Pixels are read continuing from the pixel location after the read range of the previous memory read or read memory continue. The column register is then incremented and pixels are read from the frame memory until the column register equals the end column (XE) value. The colu mn register is then reset to XS and the page register is incremented. Pixels are read from the frame memory until the page register equals the end page (YE) value and the column register equals the XE value, or the host processor sends another command. If MV=1: Pixels are read continuing from the pixel location after the read range of the previous memory read or read memory continue. The page register is then incremented and pixels are read from the frame memory until the page register equals the end page (YE) value. The page register is then reset to YS and the column register is incremented. Pixels are read from the frame memory until the column register equals the end column (XE) value and the page register equals the YE value, or the host processor sends another command. Restriction Regardless of the color mode set in interface pixel format, the pixel format returned by read memory continue is always 18-bit so there is no restriction on the length of data Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Contents of memory is set randoml y S/W Reset Contents of memory is not cleared
Version 1.0 Page 230 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. H/W Reset Contents of memory is not cleared Flow Chart
Version 1.0 Page 231 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.35 STE (44h): Set Tear Scanline
44H STE (Set Tear ScanLine ) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX STE 0 ↑ 1 - 0 1 0 0 0 1 0 0 (44h) 1st parameter 1 ↑ 1 - N15 N14 N13 N12 N11 N10 N9 N8 2nd parameter 1 ↑ 1 - N7 N6 N5 N4 N3 N2 N1 N0 -This command turns on the display module’s Tearing Effect output signal on the TE signal line when the display module reaches line N. The TE signal is not affected by changing MV. -The tearing effect line on has one parameter that describes the tearing effect output line mode. -The tearing effect output line consist of V-blanking information only. Tvdl Tvdh Vertical time scale Note that set tear scanline with N=0 is equivalent to tearing effect line on with TEM=0. The tearing effect output line shall be active low when the display module is in sleep mode Restriction This command takes affect on the frame following the current frame. Therefore, if the tear effect (TE) output is already on, the TE output shall continue to operate as programmed by the previous tearing effect line on or set tear scanline command until the end of the frame Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000h S/W Reset 0000h H/W Reset 0000h
Version 1.0 Page 232 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart Command Parameter Display Action Mode Legend Sequential transter TE Output On or OFF Set Tear on TE Output ON Line N (LSB) Line N (MSB)
Version 1.0 Page 233 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.36 GSCAN (45h): Get Scanline
45H GSCAN (Get ScanLine ) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX GSCAN 0 ↑ 1 - 0 1 0 0 0 1 0 1 (45h) 1st parameter 1 1 ↑ - - - - - - - - - 2nd parameter 1 1 ↑ - N15 N14 N13 N12 N11 N10 N9 N8 3rd parameter 1 1 ↑ - N7 N6 N5 N4 N3 N2 N1 N0 -The display module returns the current scanline ,N, used to update the display device. The total number of scanlines on a display device is defined as VSYNC+VBP+VACT+VFP. The first scanline is defined as the first line of V Sync and is denoted as Line 0. -When in sleep in mode, the value returned by get scanline is undefined. Restriction - Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000h S/W Reset 0000h H/W Reset 0000h
Version 1.0 Page 234 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart Command Parameter Display Action Mode Legend Sequential transter Get scanline Line N (MSB) Line N (LSB) Dummy read
Version 1.0 Page 235 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.37 WRDISBV (51h): Write Display Brightness
51H WRDISBV (Write Display Brightness) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX WRDISBV 0 ↑ 1 - 0 1 0 1 0 0 0 1 (51h) Parameter 1 ↑ 1 - DBV7 DBV6 DBV5 DBV4 DBV3 DBV2 DBV1 DBV0 -This command is used to adjust the brightness value of the display. -It should be checked what the relationship between this written value and output brightness of the display is. This relationship is defined on the display module specification. -In principle relationship is that 00h value means the lowest brightness and FFh value means the highest brightness. Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000h S/W Reset 0000h H/W Reset 0000h
Version 1.0 Page 236 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart Command Parameter Display Action Mode Legend Sequential transter WRDISBV DBV[7:0] New Display Luminance Value Loaded
Version 1.0 Page 237 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.38 RDDISBV (52h): Read Display Brightness Value
52H RDDISBV (Read Display Brightness Value ) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDDISBV 0 ↑ 1 - 0 1 0 1 0 0 1 0 (52h) 1st parameter 1 1 ↑ - - - - - - - - - 2nd parameter 1 1 ↑ - DBV7 DBV6 DBV5 DBV4 DBV3 DBV2 DBV1 DBV0 -This command returns the brightness value of the display. -It should be checked what the relationship between this returned value and output brightness of the display. This relationship is defined on the display module specification is. -In principle the relationship is that 00h value means the lowest brightness and FFh value means the highest brightness. -DBV[7:0] is reset when display is in sleep in mode. -DBV[7:0] is ‘0’ when bit BCTRL of write CTRL display command (53h) is ‘0’ -DBV[7:0] IS manual set brightness specified with write CTRL display command (53h) when bit BCTRL is ‘1’ Restriction - Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000h S/W Reset 0000h H/W Reset 0000h
Version 1.0 Page 238 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart
Version 1.0 Page 239 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.39 WRCTRLD (53h): Write CTRL Display
53H WRCTRLD (Write CTRL Display ) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX WRCTRLD 0 ↑ 1 - 0 1 0 1 0 0 1 1 (53h) Parameter 1 ↑ 1 - 0 0 BCTRL 0 DD BL 0 0 -This command is used to control display brightness. -BCTRL: Brightness Control Block On/Off, This bit is always used to switch brightness for display. 0 = Off (Brightness register are 00h, DBV[7:0]) 1 = On (Brightness register are active, according to the other parameters.) -DD: Display Dimming (Only for manual brightness setting) DD = 0: Display Dimming is off. DD = 1: Display Dimming is on. -BL: Backlight Control On/Off 0 = Off (Completely turn off backlight circuit. Control lines must be low.) 1 = On -Dimming function is adapted to the brightness registers for display when bit BCTRL is changed at DD=1. -When BL bit changed from ‘on’ to ‘off’, backlight is turned off without gradual dimming, even if dimming-on (DD=1) are selected. Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000h S/W Reset 0000h H/W Reset 0000h
Version 1.0 Page 240 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart Command Parameter Display Action Mode Legend Sequential transter WRCTRLD BCTRL, DD, BL New control Value loaded
Version 1.0 Page 241 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.40 RDCTRLD (54h): Read CTRL Value Display
54H RDCTRLD (Read CTRL value Display ) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDCTRLD 0 ↑ 1 - 0 1 0 1 0 1 0 0 (54h) 1st parameter 1 1 ↑ - - - - - - - - - 2nd parameter 1 1 ↑ - 0 0 BCTRL 0 DD BL 0 0 -This command returns ambient light and brightness control values.. -BCTRL: Brightness Control Block On/Off, This bit is always used to switch brightness for display. 0 = Off 1 = On -DD: Display Dimming (Only for manual brightness setting) DD = 0 DD = 1 -BL: Backlight Control On/Off 0 = Off 1 = On Restriction - Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000h S/W Reset 0000h H/W Reset 0000h
Version 1.0 Page 242 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart
Version 1.0 Page 243 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.41 WRCACE (55h): Write Content Adaptive Brightness Control and Color Enhancement
55H WRCACE (Write Content Adaptive Brightness Control and Color Enhancement) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX WRCACE 0 ↑ 1 - 0 1 0 1 0 1 0 1 (55h) Parameter 1 ↑ 1 - CECTRL 0 CE1 CE0 0 0 C1 C0 -This command is used to set parameters for image content based adaptive brightness control functionality and Color Enhancement function. -There is possible to used 4 different modes for content adaptive image functionality, which are defined on a table below. C1 C0 Function 0 0 Off 0 1 User Interface Mode 1 0 Still Picture 1 1 Moving Image -CECTRL: Color Enhancement Control Bit: CECTRL=0: Color Enhancement Off. CECTRL=1: Color Enhancement On. -There are three color enhancement levels can be set. CE1 CE0 Color enhancement level 0 0 Low enhancement 0 1 Medium enhancement 1 1 High enhancement ‘-’: Don’t care Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000h S/W Reset 0000h H/W Reset 0000h
Version 1.0 Page 244 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart Command Parameter Display Action Mode Legend Sequential transter WRCACE 1st parameter: C[1:0] New Adaptive Image Mode
Version 1.0 Page 245 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.42 RDCABC (56h): Read Content Adaptive Brightness Control
56H RDCABC (Read Content Adaptive Brightness Control ) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDCABC 0 ↑ 1 - 0 1 0 1 0 1 1 0 (56h) 1st parameter 1 1 ↑ - - - - - - - - - 2nd parameter 1 1 ↑ - 0 0 0 0 0 0 C1 C0 -This command is used to read the settings for image content based adaptive brightness control functionality. -There is possible to used 4 different modes for content adaptive image functionality, which are defined on a table below. C1 C0 Function 0 0 Off 0 1 User Interface Mode 1 0 Still Picture 1 1 Moving Image ‘-’: Don’t care Restriction - Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000h S/W Reset 0000h H/W Reset 0000h
Version 1.0 Page 246 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart
Version 1.0 Page 247 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.43 WRCABCMB (5Eh): Write CABC Minimum Brightnes s
5EH WRCABCMB (Write CABC Minimum Brightness ) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX WRCABCMB 0 ↑ 1 - 0 1 0 1 1 1 1 0 (5Eh) Parameter 1 ↑ 1 - CMB7 CMB6 CMB5 CMB4 CMB3 CMB2 CMB1 CMB0 -This command is used to set the minimum brightness value of the display for CABC function. -In principle relationship is that 00h value means the lowest brightness for CABC and FFh value means the brightness for CABC. ‘-’: Don’t care Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000h S/W Reset 0000h H/W Reset 0000h
Version 1.0 Page 248 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart Command Parameter Display Action Mode Legend Sequential transter WRCABCMB CMB[7:0] New Display Luminance Value Loaded
Version 1.0 Page 249 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.44 RDCABCMB (5Fh): Read CABC Minimum Brightness
5FH RDCABCMB (Read CABC Minimum Brightness) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDCABCMB 0 ↑ 1 - 0 1 0 1 1 1 1 1 (5Fh) 1st parameter 1 1 ↑ - - - - - - - - - 2nd parameter 1 1 ↑ - CMB7 CMB6 CMB5 CMB4 CMB3 CMB2 CMB1 CMB0 -This command returns the minimum brightness value of CABC function. -In principle relationship is that 00h value means the lowest brightness for CABC and FFh value means the brightness for CABC. ‘-’: Don’t care Restriction - Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0000h S/W Reset 0000h H/W Reset 0000h Flow Chart
Version 1.0 Page 250 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.45 RDABCSDR (68h): Read Automatic Brightness Control Self-Diagnostic Result
68H RDABCSDR (Read Automatic Brightness Control Self-Diagnostic Result) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDABCSDR 0 ↑ 1 - 0 1 1 0 1 0 0 0 (68h) 1st parameter 1 1 ↑ - - - - - - - - - - 2nd parameter 1 1 ↑ - D7 D6 0 0 0 0 0 0 - This command indicates the current status of the display self-diagnostic results for automatic brightness control after sleep out -command as described below: -D7: Register loading detection -D6: Functionality detection “-“ Don’t care Restriction Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 00h S/W Reset 00h H/W Reset 00h
Version 1.0 Page 251 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Flow Chart Command Parameter Display Action Mode Legend Sequential transter Read RDABCSDR Read RDABCSDR Send 2nd parameter Dummy Read Send 2nd parameter Serial I/F Mode Parallel I/F Mode Host Display
Version 1.0 Page 252 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.46 RDID1 (DAh): Read ID1
DAH RDID1 (Read ID1) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDID1 0 ↑ 1 - 1 1 0 1 1 0 1 0 (Dah) 1st parameter 1 1 ↑ - - - - - - - - - 2nd parameter 1 1 ↑ - ID17 ID16 ID15 ID14 ID13 ID12 ID11 ID10 Description -This read byte identifies the LCD module’s manufacturer. Restriction - Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 85h S/W Reset 85h H/W Reset 85h Flow Chart
Version 1.0 Page 253 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.47 RDID2 (DBh): Read ID2
DBH RDID2 (Read ID2) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDID2 0 ↑ 1 - 1 1 0 1 1 0 1 1 (DBh) 1st parameter 1 1 ↑ - - - - - - - - - 2nd parameter 1 1 ↑ - ID27 ID26 ID25 ID24 ID23 ID22 ID21 ID20 This read byte is used to track the LCD module/driver IC version. ‘-’: Don’t care. Restriction - Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 85h S/W Reset 85h H/W Reset 85h Flow Chart
Version 1.0 Page 254 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.1.48 RDID3 (DCh): Read ID3
DCH RDID3 (Read ID3) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RDID3 0 ↑ 1 - 1 1 0 1 1 1 0 0 (DCh) 1st parameter 1 1 ↑ - - - - - - - - - 2nd parameter 1 1 ↑ - ID37 ID36 ID35 ID34 ID33 ID32 ID31 ID30 Description This read byte identifies the LCD module/driver. Restriction - Register availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 52h S/W Reset 52h H/W Reset 52h Flow Chart
Version 1.0 Page 255 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2 System Function Command Table 2
Instruction D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 Hex Function RAMCTRL 0 ↑ 1 - 1 0 1 1 0 0 0 0 (B0h) RAM Control 1 ↑ 1 - 0 0 0 RM 0 0 DM1 DM0 1 ↑ 1 - 1 1 EPF1 EPF0 ENDIAN RIM MDT1 MDT0 RGBCTRL 0 ↑ 1 - 1 0 1 1 0 0 0 1 (B1h) RGB Control 1 ↑ 1 - WO RCM1 RCM0 0 VSPL HSPL DPL EPL 1 ↑ 1 - 0 VBP6 VBP5 VBP4 VBP3 VBP2 VBP1 VBP0 1 ↑ 1 - 0 0 0 HBP4 HBP3 HBP2 HBP1 HBP0 PORCTRL 0 ↑ 1 - 1 0 1 1 0 0 1 0 (B2h) Porch control 1 ↑ 1 - 0 BPA6 BPA5 BPA4 BPA3 BPA2 BPA1 BPA0 1 ↑ 1 - 0 FPA6 FPA5 FPA4 FPA3 FPA2 FPA1 FPA0 1 ↑ 1 - 0 0 0 0 0 0 0 PSEN 1 ↑ 1 BPB3 BPB2 BPB1 BPB0 FPB3 FPB2 FPB1 FPB0 1 ↑ 1 BPC3 BPC2 BPC1 BPC0 FPC3 FPC2 FPC1 FPC0 FRCTRL1 0 ↑ 1 - 1 0 1 1 0 0 1 1 (B3h) Frame Rate Control 1 1 ↑ 1 - 0 0 0 FRSEN 0 0 DIV1 DIV0 1 ↑ 1 - NLB2 NLB1 NLB0 RTNB4 RTNB3 RTNB2 RTNB1 RTNB0 1 ↑ 1 - NLC2 NLC1 NLC0 RTNC4 RTNC3 RTNC2 RTNC1 RTNC0 PARCTRL 0 ↑ 1 - 1 0 1 1 0 1 0 1 (B5h) Partial control 1 ↑ 1 - NDL 0 0 PTGISC ISC3 ISC2 ISC1 ISC0 GCTRL 0 ↑ 1 - 1 0 1 1 0 1 1 1 (B7h) Gate control 1 ↑ 1 - 0 VGHS2 VGHS1 VGHS0 0 VGLS2 VGLS1 VGLS0 GTADJ 0 ↑ 1 - 1 0 1 1 1 0 0 0 (B8h) Gate on timing adjustment 1 ↑ 1 - 0 0 1 0 1 0 1 0 1 ↑ 1 - 0 0 1 0 1 0 1 1 1 ↑ 1 - 0 0 GTA5 GTA4 GTA3 GTA2 GTA1 GTA0 1 ↑ 1 - GOFR3 GOFR2 GOFR1 GOFR0 GOF3 GOF2 GOF1 GOF0 DGMEN 0 ↑ 1 - 1 0 1 1 1 0 1 0 (BAh) Digital Gamma Enable 1 ↑ 1 - 0 0 0 0 0 DGMEN 0 0 VCOMS 0 ↑ 1 - 1 0 1 1 1 0 1 1 (BBh) VCOM Setting 1 ↑ 1 - 0 0 VCOMS5 VCOMS4 VCOMS3 VCOMS2 VCOMS1 VCOMS0 POWSAVE 0 ↑ 1 - 1 0 1 1 1 1 0 0 (BCh) Power saving mode 1 ↑ 1 - 1 1 1 0 1 1 NS IS
Version 1.0 Page 256 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Instruction D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 Hex Function DLPOFFSAVE 0 ↑ 1 - 1 0 1 1 1 1 0 1 (BDh) Display off power save 1 ↑ 1 - 1 1 1 1 1 1 1 DOFSAVE LCMCTRL 0 ↑ 1 - 1 1 0 0 0 0 0 0 (C0h) LCM Control 1 ↑ 1 - 0 XMY XBGR XINV XMX XMH XMV XGS IDSET 0 ↑ 1 - 1 1 0 0 0 0 0 1 (C1h) ID Setting 1 ↑ 1 - ID17 ID16 ID15 ID14 ID13 ID12 ID11 ID10 1 ↑ 1 - ID27 ID26 ID25 ID24 ID23 ID22 ID21 ID20 1 ↑ 1 - ID37 ID36 ID35 ID34 ID33 ID32 ID31 ID30 VDVVRHEN 0 ↑ 1 - 1 1 0 0 0 0 1 0 (C2h) VDV and VRH Command Enable 1 ↑ 1 - 0 0 0 0 0 0 0 CMDEN 1 ↑ 1 - 1 1 1 1 1 1 1 1 VRHS 0 ↑ 1 1 1 0 0 0 0 1 1 (C3h) VRH Set 1 ↑ 1 0 0 VRHS5 VRHS4 VRHS3 VRHS2 VRHS1 VRHS0 VDVSET 0 ↑ 1 - 1 1 0 0 0 1 0 0 (C4h) VDV Setting 1 ↑ 1 - 0 0 VDVS5 VDVS4 VDVS3 VDVS2 VDVS1 VDVS0 VCMOFSET 0 ↑ 1 - 1 1 0 0 0 1 0 1 (C5h) VCOM Offset Set 1 ↑ 1 - 0 0 VCMOFS5 VCMOFS4 VCMOFS3 VCMOFS2 VCMOFS1 VCMOFS0 FRCTR2 0 ↑ 1 1 1 0 0 0 1 1 0 (C6h) FR Control 2 1 ↑ 1 NLA2 NLA1 NLA0 RTNA4 RTNA3 RTNA2 RTNA1 RTNA0 CABCCTRL 0 ↑ 1 - 1 1 0 0 0 1 1 1 (C7h) CABC Control 1 ↑ 1 - 0 0 0 0 LEDONREV DPOFPWM PWMFIX PWMPOL REGSEL1 0 ↑ 1 - 1 1 0 0 1 0 0 0 (C8h) Register value selection1 1 ↑ 1 - 0 0 0 0 1 0 0 0 REGSEL2 0 ↑ 1 - 1 1 0 0 1 0 1 0 (CAh) Register value selection2 1 ↑ 1 - 0 0 0 0 1 1 1 1 PWMFRSEL 0 ↑ 1 - 1 1 0 0 1 1 0 0 (CCh) PWM Frequency Selection 1 ↑ 1 - 0 0 CS2 CS1 CS0 CLK2 CLK1 CLK0 PWCTRL1 0 ↑ 1 - 1 1 0 1 0 0 0 0 (D0h) Power Control 1 1 ↑ 1 - 1 0 1 0 0 1 0 0 1 ↑ 1 - AVDD1 AVDD0 AVCL1 AVCL0 0 0 VDS1 VDS0
Version 1.0 Page 257 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Instruction D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 Hex Function VAPVANEN 0 ↑ 1 - 1 1 0 1 0 0 1 0 (D2h) Enable VAP/VAN signal output 1 ↑ 1 - 0 1 0 0 1 1 0 0 CMD2EN 0 ↑ 1 - 1 1 0 1 1 1 1 1 (DFh) Command
2 Enable
1 ↑ 1 - 0 1 0 1 1 0 1 0 (5Ah) 1 ↑ 1 - 0 1 1 0 1 0 0 1 (69h) 1 ↑ 1 - 0 0 0 0 0 0 1 0 (02h) 1 ↑ 1 - 0 0 0 0 0 0 0 EN PVGAMCTRL 0 ↑ 1 - 1 1 1 0 0 0 0 0 (E0h) Positive Voltage Gamma Control 1 ↑ 1 - V63P3 V63P2 V63P1 V63P0 V0P3 V0P2 V0P1 V0P0 1 ↑ 1 - 0 0 V1P5 V1P4 V1P3 V1P2 V1P1 V1P0 1 ↑ 1 - 0 0 V2P5 V2P4 V2P3 V2P2 V2P1 V2P0 1 ↑ 1 - 0 0 0 V4P4 V4P3 V4P2 V4P1 V4P0 1 ↑ 1 - 0 0 0 V6P4 V6P3 V6P2 V6P1 V6P0 1 ↑ 1 - 0 0 J0P1 J0P0 V13P3 V13P2 V13P1 V13P0 1 ↑ 1 - 0 V20P6 V20P5 V20P4 V20P3 V20P2 V20P1 V20P0 1 ↑ 1 - 0 V36P2 V36P1 V36P0 0 V27P2 V27P1 V27P0 1 ↑ 1 - 0 V43P6 V43P5 V43P4 V43P3 V43P2 V43P1 V43P0 1 ↑ 1 - 0 0 J1P1 J1P0 V50P3 V50P2 V50P1 V50P0 1 ↑ 1 - 0 0 0 V57P4 V57P3 V57P2 V57P1 V57P0 1 ↑ 1 - 0 0 0 V59P4 V59P3 V59P2 V59P1 V59P0 1 ↑ 1 - 0 0 V61P5 V61P4 V61P3 V61P2 V61P1 V61P0 1 ↑ 1 - 0 0 V62P5 V62P4 V62P3 V62P2 V62P1 V62P0 NVGAMCTRL 0 ↑ 1 - 1 1 1 0 0 0 0 1 (E1h) Negative Voltage Gamma Control 1 ↑ 1 - V63N3 V63N2 V63N1 V63N0 V0N3 V0N2 V0N1 V0N0 1 ↑ 1 - 0 0 V1N5 V1N4 V1N3 V1N2 V1N1 V1N0 1 ↑ 1 - 0 0 V2N5 V2N4 V2N3 V2N2 V2N1 V2N0 1 ↑ 1 - 0 0 0 V4N4 V4N3 V4N2 V4N1 V4N0 1 ↑ 1 - 0 0 0 V6N4 V6N3 V6N2 V6N1 V6N0
Version 1.0 Page 258 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Instruction D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 Hex Function 1 ↑ 1 - 0 0 J0N1 J0N0 V13N3 V13N2 V13N1 V13N0 1 ↑ 1 0 V20N6 V20N5 V20N4 V20N3 V20N2 V20N1 V20N0 1 ↑ 1 0 V36N2 V36N1 V36N0 0 V27N2 V27N1 V27N0 1 ↑ 1 0 V43N6 V43N5 V43N4 V43N3 V43N2 V43N1 V43N0 1 ↑ 1 0 0 J1N1 J1N0 V50N3 V50N2 V50N1 V50N0 1 ↑ 1 0 0 0 V57N4 V57N3 V57N2 V57N1 V57N0 1 ↑ 1 0 0 0 V59N4 V59N3 V59N2 V59N1 V59N0 1 ↑ 1 0 0 V61N5 V61N4 V61N3 V61N2 V61N1 V61N0 1 ↑ 1 0 0 V62N5 V62N4 V62N3 V62N2 V62N1 V62N0 DGMLUTR 0 ↑ 1 - 1 1 1 0 0 0 1 0 (E2h) Digital Gamma Look-up Table for Red 1 ↑ 1 - DGM_LUT_R00[7:0] 1 ↑ 1 - DGM_LUT_R01[7:0] 1 ↑ 1 - 1 ↑ 1 - DGM_LUT_R30[7:0] 1 ↑ 1 - DGM_LUT_R31[7:0] 1 ↑ 1 - 1 ↑ 1 - DGM_LUT_R62[7:0] 1 ↑ 1 - DGM_LUT_R63[7:0] DGMLUTB 0 ↑ 1 - 1 1 1 0 0 0 1 1 (E3h) Digital Gamma Look-up Table for Blue 1 ↑ 1 - DGM_LUT_B00[7:0] 1 ↑ 1 - DGM_LUT_B01[7:0] 1 ↑ 1 - 1 ↑ 1 - DGM_LUT_B30[7:0] 1 ↑ 1 - DGM_LUT_B31[7:0] 1 ↑ 1 - 1 ↑ 1 - DGM_LUT_B62[7:0] 1 ↑ 1 - DGM_LUT_B63[7:0] GATECTRL 0 ↑ 1 - 1 1 1 0 0 1 0 0 (E4h) Gate control 1 ↑ 1 - 0 0 NL5 NL4 NL3 NL2 NL1 NL0
Version 1.0 Page 259 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Instruction D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 Hex Function 1 ↑ 1 - 0 0 SCN5 SCN4 SCN3 SCN2 SCN1 SCN0 1 ↑ 1 - 0 0 0 TMG 0 SM 0 GS SPI2EN 0 ↑ 1 - 1 1 1 0 0 1 1 1 (E7h) SPI2 enable 1 ↑ 1 - 0 0 0 SPI2EN 0 0 0 SPIRD PWCTRL2 0 ↑ 1 - 1 1 1 0 1 0 0 0 (E8h) Power Control 2 1 ↑ 1 - 1 0 SBCLK1 SBCLK0 0 0 STP14CK1 STP14CK0 EQCTRL 0 ↑ 1 - 1 1 1 0 1 0 0 1 (E9h) Equalize Time Control 1 ↑ 1 - 0 0 0 SEQ4 SEQ3 SEQ2 SEQ1 SEQ0 1 ↑ 1 - 0 0 0 SPRET4 SPRET3 SPRET2 SPRET1 SPRET0 1 ↑ 1 - 0 0 0 0 GEQ3 GEQ2 GEQ1 GEQ0 PROMCTRL 0 ↑ 1 - 1 1 1 0 1 1 0 0 (ECh) Program Control 1 ↑ 1 - 0 0 0 0 0 0 0 1 PROMEN 0 ↑ 1 - 1 1 1 1 1 0 1 0 (FAh) Program Mode Enable 1 ↑ 1 - 0 1 0 1 1 0 1 0 1 ↑ 1 - 0 1 1 0 1 0 0 1 1 ↑ 1 - 1 1 1 0 1 1 1 0 1 ↑ 1 - 0 0 0 0 0 PROMEN 0 0 NVMSET 0 ↑ 1 - 1 1 1 1 1 1 0 0 (FCh) NVM Setting 1 ↑ 1 - ADD7 ADD6 ADD5 ADD4 ADD3 ADD2 ADD1 ADD0 1 ↑ 1 - D7 D6 D5 D4 D3 D2 D1 D0 PROMACT 0 ↑ 1 - 1 1 1 1 1 1 1 0 (FEh) Program Action 1 ↑ 1 - 0 0 0 1 1 0 0 1 1 ↑ 1 - 1 0 1 0 0 1 0 1
Version 1.0 Page 260 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.1 RAMCTRL (B0h): RAM Control
B0H RAMCTR (RAM Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RAMCTRL 0 ↑ 1 - 1 0 1 1 0 0 0 0 (B0h) 1st Parameter 1 ↑ 1 - 0 0 0 RM 0 0 DM1 DM0 2nd Parameter 1 ↑ 1 - 1 1 EPF1 EPF0 ENDIAN RIM MDT1 MDT0 RM : ram access selection. RM=”0” : Ram access from MCU interface RM=”1” : Ram access from RGB interface DM[1:0] : Display operation selection. DM[1:0] Mode 00h MCU interface 01h RGB interface 10h VSYNC interface 11h Reserved ENDIAN : ENDIAN Mode
0 Normal (MSB first)
1 Little Endian (LSB first)
Note: Little Endian only can be supported in 65K 8-bit and 9-bit interface. MDT[1:0] : Method of pixel data transfer. Please refer to section 8.8 Data Color Coding
Version 1.0 Page 261 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. RIM: Specify RGB interface bus width. RIM=”0”: 18 bit bus width. RIM=”1”: 6 bit bus width EPF[1:0] : Data translate of 65k and 4k to frame data. 65K data formate: DB 15 DB 14 DB 13 DB 12 DB 11 DB 10 DB 9 DB 8 DB 7 DB 6 DB 5 DB 4 DB 3 DB 2 DB 1 DB 0Data Bus R5 R4 R3 R2 R1 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1Frame Data 0 0 EPF=00 DB 15 DB 14 DB 13 DB 12 DB 11 DB 10 DB 9 DB 8 DB 7 DB 6 DB 5 DB 4 DB 3 DB 2 DB 1 DB 0Read Data DB 15 DB 14 DB 13 DB 12 DB 11 DB 10 DB 9 DB 8 DB 7 DB 6 DB 5 DB 4 DB 3 DB 2 DB 1 DB 0Data Bus R5 R4 R3 R2 R1 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B11 1 EPF=01 DB 15 DB 14 DB 13 DB 12 DB 11 DB 10 DB 9 DB 8 DB 7 DB 6 DB 5 DB 4 DB 3 DB 2 DB 1 DB 0Read Data DB 15 DB 14 DB 13 DB 12 DB 11 DB 10 DB 9 DB 8 DB 7 DB 6 DB 5 DB 4 DB 3 DB 2 DB 1 DB 0Data Bus R5 R4 R3 R2 R1 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1R0 B0 EPF=10 DB 15 DB 14 DB 13 DB 12 DB 11 DB 10 DB 9 DB 8 DB 7 DB 6 DB 5 DB 4 DB 3 DB 2 DB 1 DB 0Read Data DB 15 DB 14 DB 13 DB 12 DB 11 DB 10 DB 9 DB 8 DB 7 DB 6 DB 5 DB 4 DB 3 DB 2 DB 1 DB 0Data Bus R5 R4 R3 R2 R1 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1R0 B0 EPF=11 DB 15 DB 14 DB 13 DB 12 DB 11 DB 10 DB 9 DB 8 DB 7 DB 6 DB 5 DB 4 DB 3 DB 2 DB 1 DB 0Read Data Register Availability Status Availability
Version 1.0 Page 262 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 00h/F0h S/W Reset 00h/F0h H/W Reset 00h/F0h
Version 1.0 Page 263 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.2 RGBCTRL (B1h): RGB Interface Control
B1H RGBCTRL (RGB Interface Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX RGBCTRL 0 ↑ 1 - 1 0 1 1 0 0 0 1 (B1h) 1st parameter 1 ↑ 1 - WO RCM1 RCM0 0 VSPL HSPL DPL EPL 2nd parameter 1 ↑ 1 - 0 VBP6 VBP5 VBP4 VBP3 VBP2 VBP1 VBP0 3rd parameter 1 ↑ 1 - 0 0 0 HBP4 HBP3 HBP2 HBP1 HBP0 WO: Direct RGB mode. WO Mode
0 Memory
1 Shift register
RCM[1:0]: RGB I/F enable mode selection. RCM[1:0] Mode MCU interface
10 RGB DE mode
11 RGB HV mode
VSPL : Sets the signal polarity of the VSYNC pin. VSPL=”0”, Low active VSPL=”1”, High active HSPL : Sets the signal polarity of the HSYNC pin. HSPL=”0”, Low active HSPL=”1”, High active DPL : Sets the signal polarity of the DOTCLK pin. DPL = “0” The data is input on the positive edge of DOTCLK DPL = “1” The data is input on the negative edge of DOTCLK EPL : Sets the signal polarity of the ENABLE pin. EPL = “0” The data DB17-0 is written when ENABLE = “1”. Disable data write operation when ENABLE = “0”. EPL = “1” The data DB17-0 is written when ENABLE = “0”. Disable data write operation when ENABLE = “1”. VBP[6:0]: RGB interface Vsync back porch setting. Minimum setting is 0x02. HBP[4:0]: RGB interface Hsync back porch setting. Please refer to the section 8.9.3 for minimum setting. Register Availability
Version 1.0 Page 264 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 40h/02h/14h S/W Reset 40h/02h/14h H/W Reset 40h/02h/14h
Version 1.0 Page 265 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.3 PORCTRL (B2h): Porch Setting
B2H PORCTRL (Porch Setting) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX PORCTRL 0 ↑ 1 - 1 0 1 1 0 0 1 0 (B2h) 1st parameter 1 ↑ 1 - 0 BPA6 BPA5 BPA4 BPA3 BPA2 BPA1 BPA0 2nd parameter 1 ↑ 1 - 0 FPA6 FPA5 FPA4 FPA3 FPA2 FPA1 FPA0 3rd parameter 1 ↑ 1 - 0 0 0 0 0 0 0 PSEN 4th parameter 1 ↑ 1 - BPB3 BPB2 BPB1 BPB0 FPB3 FPB2 FPB1 FPB0 5th parameter 1 ↑ 1 - BPC3 BPC2 BPC1 BPC0 FPC3 FPC2 FPC1 FPC0 BPA[6:0]: Back porch setting in normal mode. The minimum setting is 0x01. FPA[6:0]: Front porch setting in normal mode. The minimum setting is 0x01. PSEN: Enable separate porch control. PSEN Mode
0 Disable separate porch control
1 Enable separate porch control
BPB[3:0]: Back porch setting in idle mode. The minimum setting is 0x01. FPB[3:0]: Front porch setting in idle mode. The minimum setting is 0x01. BPC[3:0]: Back porch setting in partial mode. The minimum setting is 0x01. FPC[3:0]: Front porch setting in partial mode. The minimum setting is 0x01. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0Ch/0Ch/00h/33h/33h S/W Reset 0Ch/0Ch/00h/33h/33h H/W Reset 0Ch/0Ch/00h/33h/33h
Version 1.0 Page 266 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.4 FRCTRL1 (B3h): Frame Rate Control 1 (In partial mode/ idle colors)
B3H FRCTRL1 (Frame rate control 1) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX FRCTRL1 0 ↑ 1 - 1 0 1 1 0 0 1 1 (B3h) 1st parameter 1 ↑ 1 - 0 0 0 FRSEN 0 0 DIV1 DIV0 2nd parameter 1 ↑ 1 - NLB2 NLB1 NLB0 RTNB4 RTNB3 RTNB2 RTNB1 RTNB0 3rd parameter 1 ↑ 1 - NLC2 NLC1 NLC0 RTNC4 RTNC3 RTNC2 RTNC1 RTNC0 FRSEN: Enable separate frame rate control. When FRSEN=0, Frame rate of idle and partial mode are determined by C6h When FRSEN=1, Frame rate of idle and partial mode are determined by B3h FRSEN Mode
0 Disable separate FR control
1 Enable separate FR control
DIV[1:0]: Frame rate divided control DIV[1:0] Mode
00 Divide by 1
01 Divide by 2
10 Divide by 4
11 Divide by 8
NLB[2:0]: Inversion selection in idle mode. 0x00: dot inversion. 0x07: column inversion. RTNB[4:0]: Frame rate control in idle mode. RTNB[4:0] FR in idle mode (Hz) RTNB[4:0] FR in idle mode (Hz) 00h 119 10h 58 01h 111 11h 57 02h 105 12h 55 03h 99 13h 53 04h 94 14h 52 05h 90 15h 50 06h 86 16h 49 07h 82 17h 48 08h 78 18h 46 09h 75 19h 45
Version 1.0 Page 267 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 0Ah 72 1Ah 44 0Bh 69 1Bh 43 0Ch 67 1Ch 42 0Dh 64 1Dh 41 0Eh 62 1Eh 40 0Fh 60 1Fh 39 Note: 1. If FRSEN=1, Frame rate in idle mode=10MHz/(320+(FPB[3:0]+BPB[3:0])*4)*(250+RTNB[4:0]*16). 2. FPB[6:0] and BPB[6:0] are in command B2h 3. In this frame rate table, FPB[3:0]=03h, BPB[3:0]=03h NLC[2:0]: Inversion setting in partial mode. 0x00: dot inversion. 0x07: column inversion. RTNC[4:0]: Frame rate control in partial mode. This setting is equal to RTNB Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 00h/0Fh/0Fh S/W Reset 00h/0Fh/0Fh H/W Reset 00h/0Fh/0Fh
Version 1.0 Page 268 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.5 PARCTRL (B5h): Partial Control
B5H PARCTRL (Partial Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX PARCTRL 0 ↑ 1 - 1 0 1 1 0 1 0 1 (B5h) Parameter 1 ↑ 1 - NDL 0 0 PTGISC ISC3 ISC2 ISC1 ISC0 NDL: Source output level in non display area in partial mode. When NDL=0, source output level is V63. When NDL=1, source output level is V0. PTGISC: Non display area scan mode. When PTGISC=0, non-display area is normal scan. When PTGISC=1, non-display area is interval scan. ISC[3:0]: non-display area scan cycle selection. ISC[3:0] Scan cycle for non-display area 00h Normal scan 01h Every 3 cycles scan 1 time 02h Every 5 cycles scan 1 time 03h Every 7 cycles scan 1 time ….. ….. 0Fh Every 31 cycles scan 1 time Note: If 01h to 0fh of ISC[3:0] need to be set, PTGISC have to set to 1. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 00h S/W Reset 00h H/W Reset 00h
Version 1.0 Page 269 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.6 GCTRL (B7h): Gate Control
B7H GCTRL (Gate Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX GCTRL 0 ↑ 1 - 1 0 1 1 0 1 1 1 (B7h) Parameter 1 ↑ 1 - 0 VGHS2 VGHS1 VGHS0 0 VGLS2 VGLS1 VGLS0 VGHS[2:0]: VGH Setting. VGHS[2:0] VGH (V) 00h 12.2 01h 12.54 02h 12.89 03h 13.26 04h 13.65 05h 14.06 06h 14.5 07h 14.97 VGLS[2:0]: VGL Setting. VGLS[2:0] VGL (V) 00h -7.16 01h -7.67 02h -8.23 03h -8.87 04h -9.6 05h -10.43 06h -11.38 07h -12.5 Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes
Version 1.0 Page 270 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Default Status Default Value Power On Sequence 35h S/W Reset 35h H/W Reset 35h
Version 1.0 Page 271 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.7 GTADJ (B8h): Gate On Timing Adjustment
B8H GTADJ(Gate On Timing Adjustment) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX GTADJ 0 ↑ 1 - 1 0 1 1 1 0 0 0 (B8h) 1st Parameter 1 ↑ 1 - 0 0 1 0 1 0 1 0 2Ah 2nd Parameter 1 ↑ 1 - 0 0 1 0 1 0 1 1 2Bh 3rd Parameter 1 ↑ 1 - 0 0 GTA5 GTA4 GTA3 GTA2 GTA1 GTA0 4th Parameter 1 ↑ 1 - GOFR3 GOFR2 GOFR1 GOFR0 GOF3 GOF2 GOF1 GOF0 GTA[5:0]: Gate on timing adjustment. Gate on timing=300ns+GTA[5:0]*400ns In RGB interface: In 18bit RGB interface: Gate on timing=7dotclk+GTA[5:0]*4dotclk In 6bit RGB interface: Gate on timing=7*3dotclk+GTA[5:0]*4*3dotclk GOFR[3:0]: Gate off timing adjustment only for RGB interface In 18bit RGB interface: Gate off timing=516.5dotclk-16dotclk*GOFR[3:0] In 6bit RGB interface: Gate off timing=512*3dotclk-16dotclk*3*GOFR[3:0] Note:
Version 1.0 Page 272 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. In rgb interface, if the setting of gate off timing is more than the number of dotclk in one line, the gate off timing is determined by hsync. GOF[3:0]: Gate off timing adjustment Gate off timing=-GOF[3:0]*400ns Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 2Ah/2Bh/22h/75h S/W Reset 2Ah/2Bh/22h/75h H/W Reset 2Ah/2Bh/22h/75h
Version 1.0 Page 273 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.8 DGMEN (BAh): Digital Gamma Enable
BAH DGMEN (Digital Gamma Enable) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX DGMEN 0 ↑ 1 - 1 0 1 1 1 0 1 0 (BAh) Parameter 1 ↑ 1 - 0 0 0 0 0 DGMEN 0 0 DGMEN: “0”: disable digital gamma. “1”: enable digital gamma. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 00h S/W Reset 00h H/W Reset 00h
Version 1.0 Page 274 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.9 VCOMS (BBh): VCOM Setting
BBH VCOMS (VCOM Setting) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX VCOMS 0 ↑ 1 - 1 0 1 1 1 0 1 1 (BBh) Parameter 1 ↑ 1 - 0 0 VCOM5 VCOM4 VCOM3 VCOM2 VCOM1 VCOM0 VCOMS[5:0]: VCOMS[5:0] VCOM (V) VCOMS[5:0] VCOM (V) 00h 0.1 20h 0.9 01h 0.125 21h 0.925 02h 0.15 22h 0.95 03h 0.175 23h 0.975 04h 0.2 24h 1.0 05h 0.225 25h 1.025 06h 0.25 26h 1.05 07h 0.275 27h 1.075 08h 0.3 28h 1.1 09h 0.325 29h 1.125 0Ah 0.35 2Ah 1.15 0Bh 0.375 2Bh 1.175 0Ch 0.4 2Ch 1.2 0Dh 0.425 2Dh 1.225 0Eh 0.45 2Eh 1.25 0Fh 0.475 2Fh 1.275 10h 0.5 30h 1.3 11h 0.525 31h 1.325 12h 0.55 32h 1.35 13h 0.575 33h 1.375 14h 0.6 34h 1.4 15h 0.625 35h 1.425 16h 0.65 36h 1.45 17h 0.675 37h 1.475 18h 0.7 38h 1.5 19h 0.725 39h 1.525 1Ah 0.75 3Ah 1.55 1Bh 0.775 3Bh 1.575 1Ch 0.8 3Ch 1.6
Version 1.0 Page 275 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 1Dh 0.825 3Dh 1.625 1Eh 0.85 3Eh 1.65 1Fh 0.875 3Fh 1.675 Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 20h S/W Reset 20h H/W Reset 20h
Version 1.0 Page 276 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.10 POWSAVE(BCh): Power Saving Mode
BCH POWSAVE (Power Saving Mode) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX POWSAVE 0 ↑ 1 - 1 0 1 1 1 1 0 0 (BCh) Parameter 1 ↑ 1 - 1 1 1 0 1 1 NS IS NS: Power save for normal mode. When NS=0, power consumption in normal mode will be saved. IS: Power save for Idle mode. When IS=0, power consumption in idle mode will be saved. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence FFh S/W Reset FFh H/W Reset FFh
Version 1.0 Page 277 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.11 DLPOFFSAVE (BDh): Display off power save
BDH DLPOFFSAVE (Display off power save) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX DLPOFFSAVE 0 ↑ 1 - 1 0 1 1 1 1 0 1 (BDh) Parameter 1 ↑ 1 - 1 1 1 1 1 1 1 DOFSAVE DOFSAVE: Power save for display off mode. When DOFSAVE=0, power consumption in display off mode will be saved. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence FFh S/W Reset FFh H/W Reset FFh
Version 1.0 Page 278 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.12 LCMCTRL (C0h): LCM Control
C0H LCMCTRL (LCM Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX LCMCTRL 0 ↑ 1 - 1 1 0 0 0 0 0 0 (C0h) 1st parameter 1 ↑ 1 - 0 XMY XBGR XINV XMX XMH XMV XGS XMY: XOR MY setting in command 36h. XBGR: XOR RGB setting in command 36h. XREV: XOR inverse setting in command 21h XMH: this bit can reverse source output order and only support for RGB interface without RAM mode XMV: XOR MV setting in command 36h XMX: XOR MX setting in command 36h. XGS: XOR GS setting in command E4h. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 2Ch S/W Reset 2Ch H/W Reset 2Ch
Version 1.0 Page 279 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.13 IDSET (C1h): ID Code Setting
C1H IDSET (ID Code Setting) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX IDSET 0 ↑ 1 - 1 1 0 0 0 0 0 1 (C1h) Parameter 1st 1 ↑ 1 - ID17 ID16 ID15 ID14 ID13 ID12 ID11 ID10 Parameter 2 nd 1 ↑ 1 - ID27 ID26 ID25 ID24 ID23 ID22 ID21 ID20 Parameter 3 rd 1 ↑ 1 - ID37 ID36 ID35 ID34 ID33 ID32 ID31 ID30 ID1[7:0]: ID1 Setting. ID2[7:0]: ID2 Setting. ID3[7:0]: ID3 Setting. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 85h/85h/52h S/W Reset 85h/85h/52h H/W Reset 85h/85h/52h
Version 1.0 Page 280 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.14 VDVVRHEN (C2h): VDV and VRH Command Enable
C2H VDVVRHEN (VDV and VRH Command Enable) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX VDVVRHEN 0 ↑ 1 - 1 1 0 0 0 0 1 0 (C2h) 1st Parameter 1 ↑ 1 - 0 0 0 0 0 0 0 CMDEN 2nd Parameter 1 ↑ 1 - 1 1 1 1 1 1 1 1 CMDEN: VDV and VRH command write enable. CMDEN=”0”: VDV and VRH register value comes from NVM. CMDEN=”1”, VDV and VRH register value comes from command write. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 01h/FFh S/W Reset 01h/FFh H/W Reset 01h/FFh
Version 1.0 Page 281 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.15 VRHS (C3h): VRH Set
C3H VRHS (VRH Set) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX VRHS 0 ↑ 1 - 1 1 0 0 0 0 1 1 (C3h) 1st Parameter 1 ↑ 1 - 0 0 VRHS5 VRHS4 VRHS3 VRHS2 VRHS1 VRHS0 VRHS[5:0]: VRH Set. VRHS[5:0] VAP(GVDD) (V) VRHS[5:0] VAP(GVDD) (V) 00h 3.55+(vcom+vcom offset+vdv) 15h 4.6+( vcom+vcom offset+vdv) 01h 3.6+( vcom+vcom offset+vdv) 16h 4.65+( vcom+vco m offset+vdv) 02h 3.65+( vcom+vcom offset+vdv) 17h 4.7+( vcom+vco m offset+vdv) 03h 3.7+( vcom+vcom offset+vdv) 18h 4.75+( vcom+vco m offset+vdv) 04h 3.75+( vcom+vcom offset+vdv) 19h 4.8+( vcom+vco m offset+vdv) 05h 3.8+( vcom+vcom offset+vdv) 1Ah 4.85+( vcom+vcom offset+vdv) 06h 3.85+( vcom+vcom offset+vdv) 1Bh 4.9+( vcom+vcom offset+vdv) 07h 3.9+( vcom+vcom offset+vdv) 1Ch 4.95+( vcom+vco m offset+vdv) 08h 3.95+( vcom+vcom offset+vdv) 1Dh 5+( vcom+vcom offset+vdv) 09h 4+( vcom+vcom offset+vdv) 1Eh 5.05+( vcom+vcom o ffset+vdv) 0Ah 4.05+( vcom+vcom offset+vdv) 1Fh 5.1+( vcom+vcom offset+vdv) 0Bh 4.1+( vcom+vcom offset+vdv) 20h 5.15+( vcom+vcom offset+vdv) 0Ch 4.15+( vcom+vcom offset+vdv) 21h 5.2+( vcom+vco m offset+vdv) 0Dh 4.2+( vcom+vcom offset+vdv) 22h 5.25+( vcom+vco m offset+vdv) 0Eh 4.25+( vcom+vcom offset+vdv) 23h 5.3+( vcom+vcom offset+vdv) 0Fh 4.3+( vcom+vcom offset+vdv) 24h 5.35+( vcom+vco m offset+vdv) 10h 4.35+( vcom+vcom offset+vdv) 25h 5.4+( vcom+vco m offset+vdv) 11h 4.4+( vcom+vcom offset+vdv) 26h 5.45+( vcom+vco m offset+vdv) 12h 4.45+( vcom+vcom offset+vdv) 27h 5.5+( vcom+vco m offset+vdv) 13h 4.5+( vcom+vcom offset+vdv) 28h~3Fh Reserved 14h 4.55+( vcom+vcom offset+vdv) -- -- VRHS[5:0] VAN(GVCL) (V) VRHS[5:0] VAN(GVCL) (V) 00h -3.55+(vcom+vcom offset-vdv) 15h -4.6+( vcom+vc om offset-vdv) 01h -3.6+( vcom+vcom offset-vdv) 16h -4.65+( vcom+vcom offset-vdv) 02h -3.65+( vcom+vcom offset-vdv) 17h -4.7+( vcom+v com offset-vdv) 03h -3.7+( vcom+vcom offset-vdv) 18h -4.75+( vcom+vcom offset-vdv) 04h -3.75+( vcom+vcom offset-vdv) 19h -4.8+( vcom+v com offset-vdv) 05h -3.8+( vcom+vcom offset-vdv) 1Ah -4.85+( vcom+vcom offset-vdv)
Version 1.0 Page 282 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 06h -3.85+( vcom+vcom offset-vdv) 1Bh -4.9+( vcom+vc om offset-vdv) 07h -3.9+( vcom+vcom offset-vdv) 1Ch -4.95+( vcom+vcom offset-vdv) 08h -3.95+( vcom+vcom offset-vdv) 1Dh -5+( vcom+vco m offset-vdv) 09h -4+( vcom+vcom offset-vdv) 1Eh -5.05+( vcom+vcom offset-vdv) 0Ah -4.05+( vcom+vcom offset-vdv) 1Fh -5.1+( vcom+vc om offset-vdv) 0Bh -4.1+( vcom+vcom offset-vdv) 20h -5.15+( vcom+vcom offset-vdv) 0Ch -4.15+( vcom+vcom offset-vdv) 21h -5.2+( vcom+v com offset-vdv) 0Dh -4.2+( vcom+vcom offset-vdv) 22h -5.25+( vcom+vcom offset-vdv) 0Eh -4.25+( vcom+vcom offset-vdv) 23h -5.3+( vcom+vc om offset-vdv) 0Fh -4.3+( vcom+vcom offset-vdv) 24h -5.35+( vcom+vcom offset-vdv) 10h -4.35+( vcom+vcom offset-vdv) 25h -5.4+( vcom+v com offset-vdv) 11h -4.4+( vcom+vcom offset-vdv) 26h -5.45+( vcom+vcom offset-vdv) 12h -4.45+( vcom+vcom offset-vdv) 27h -5.5+( vcom+v com offset-vdv) 13h -4.5+( vcom+vcom offset-vdv) 28h~3Fh Reserved 14h -4.55+( vcom+vcom offset-vdv) -- -- Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0Bh S/W Reset 0Bh H/W Reset 0Bh
Version 1.0 Page 283 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.16 VDVS (C4h): VDV Set
C4H VDVS (VDV Set) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX VDVS 0 ↑ 1 - 1 1 0 0 0 1 0 0 (C4h) 1st Parameter 1 ↑ 1 - 0 0 VDVS5 VDVS4 VDVS3 VDVS2 VDVS1 VDVS0 VDVS[5:0]: VDV Set. VDVS[5:0] VDV (V) VDVS[5:0] VDV (V) 00h -0.8 20h 0 01h -0.775 21h 0.025 02h -0.75 22h 0.05 03h -0.725 23h 0.075 04h -0.7 24h 0.1 05h -0.675 25h 0.125 06h -0.65 26h 0.15 07h -0.625 27h 0.175 08h -0.6 28h 0.2 09h -0.575 29h 0.225 0Ah -0.55 2Ah 0.25 0Bh -0.525 2Bh 0.275 0Ch -0.5 2Ch 0.3 0Dh -0.475 2Dh 0.325 0Eh -0.45 2Eh 0.35 0Fh -0.425 2Fh 0.375 10h -0.4 30h 0.4 11h -0.375 31h 0.425 12h -0.35 32h 0.45 13h -0.325 33h 0.475 14h -0.3 34h 0.5 15h -0.275 35h 0.525 16h -0.25 36h 0.55 17h -0.225 37h 0.575 18h -0.2 38h 0.6 19h -0.175 39h 0.625 1Ah -0.15 3Ah 0.65 1Bh -0.125 3Bh 0.675 1Ch -0.1 3Ch 0.7
Version 1.0 Page 284 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 1Dh -0.075 3Dh 0.725 1Eh -0.05 3Eh 0.75 1Fh -0.025 3Fh 0.775 Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 20h S/W Reset 20h H/W Reset 20h
Version 1.0 Page 285 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.17 VCMOFSET (C5h): VCOM Offset Set
C5H VCMOFSET (VCOM Offset Set) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX VCMOFSET 0 ↑ 1 - 1 1 0 0 0 1 0 1 (C5h) 1st Parameter 1 ↑ 1 - 0 0 VCMOFS5 VCMOFS4 VCMOFS3 VCMOFS2 VCMOFS1 VCMOFS0 VCOM offset setting: VCMOFS[5:0] VCOM OFFSET (V) VCMOFS[5:0] VCOM OFFSET(V) 00h -0.8 20h 0 01h -0.775 21h 0.025 02h -0.75 22h 0.05 03h -0.725 23h 0.075 04h -0.7 24h 0.1 05h -0.675 25h 0.125 06h -0.65 26h 0.15 07h -0.625 27h 0.175 08h -0.6 28h 0.2 09h -0.575 29h 0.225 0Ah -0.55 2Ah 0.25 0Bh -0.525 2Bh 0.275 0Ch -0.5 2Ch 0.3 0Dh -0.475 2Dh 0.325 0Eh -0.45 2Eh 0.35 0Fh -0.425 2Fh 0.375 10h -0.4 30h 0.4 11h -0.375 31h 0.425 12h -0.35 32h 0.45 13h -0.325 33h 0.475 14h -0.3 34h 0.5 15h -0.275 35h 0.525 16h -0.25 36h 0.55 17h -0.225 37h 0.575 18h -0.2 38h 0.6 19h -0.175 39h 0.625 1Ah -0.15 3Ah 0.65 1Bh -0.125 3Bh 0.675 1Ch -0.1 3Ch 0.7
Version 1.0 Page 286 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. 1Dh -0.075 3Dh 0.725 1Eh -0.05 3Eh 0.75 1Fh -0.025 3Fh 0.775 Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 20h S/W Reset 20h H/W Reset 20h
Version 1.0 Page 287 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.18 FRCTRL2 (C6h): Frame Rate Control in Normal Mode
C6H FRCTRL2 (Frame Rate Control in Normal Mode) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX FRCTRL2 0 ↑ 1 - 1 1 0 0 0 1 1 0 (C6h) 1st Parameter 1 ↑ 1 - NLA2 NLA1 NLA0 RTNA4 RTNA3 RTNA2 RTNA1 RTNA0 NLA[2 :0] : Inversion selection in normal mode. 0x00 : dot inversion. 0x07: column inversion. RTNA[4:0]: RTNA[4:0] FR in normal mode (Hz) RTNA[4:0] FR in normal mode (Hz) 00h 119 10h 58 01h 111 11h 57 02h 105 12h 55 03h 99 13h 53 04h 94 14h 52 05h 90 15h 50 06h 86 16h 49 07h 82 17h 48 08h 78 18h 46 09h 75 19h 45 0Ah 72 1Ah 44 0Bh 69 1Bh 43 0Ch 67 1Ch 42 0Dh 64 1Dh 41 0Eh 62 1Eh 40 0Fh 60 1Fh 39 Note: 1. Frame rate=10MHz/(320+FPA[6:0]+BPA[6:0])*(250+RTNA[4:0]*16). 2. FPA[6:0] and BPA[6:0] are in command B2h 3. In this frame rate table, FPA[6:0]=0Ch, BPA[6:0]=0Ch Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes
Version 1.0 Page 288 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Sleep In Yes Default Status Default Value Power On Sequence 0Fh S/W Reset 0Fh H/W Reset 0Fh
Version 1.0 Page 289 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.19 CABCCTRL (C7h): CABC Control
C7H CABCCTRL (CABC Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX CABCCTRL 0 ↑ 1 - 1 1 0 0 0 1 1 1 (C7h) 1st Parameter 1 ↑ 1 - 0 0 0 0 LEDONREV DPOFPWM PWMFIX PWMPOL LEDONREV: Reverse the status of LED_ON: “0”: keep the status of LED_ON. “1”: reverse the status of LED_ON. DPOFPWM: initial state control of LEDPWM. “0”: The initial state of LEDPWM is low. “1”: The initial state of LEDPWM is high. PWMFIX: LEDPWM fix control. “0”: LEDPWM control by CABC. “1”: fix LEDPWM in “ON” status. PWMPOL: LEDPWM polarity control. “0”: polarity high. “1”: polarity low. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 00h S/W Reset 00h H/W Reset 00h
Version 1.0 Page 290 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.20 REGSEL1 (C8h): Register Value Selection 1
C8H REGSEL1 (Register Value Selection 1) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX REGSEL1 0 ↑ 1 - 1 1 0 0 1 0 0 0 (C8h) Parameter 1 ↑ 1 - 0 0 0 0 1 0 0 0 Description Reserved for testing Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 08h S/W Reset 08h H/W Reset 08h
Version 1.0 Page 291 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.21 REGSEL2 (CAh): Register Value Selection 2
CAH REGSEL2 (Register Value Selection 2) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX REGSEL2 0 ↑ 1 - 1 1 0 0 1 0 1 0 (Cah) Parameter 1 ↑ 1 - 0 0 0 0 1 1 1 1 Description Reserved for testing Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 0Fh S/W Reset 0Fh H/W Reset 0Fh
Version 1.0 Page 292 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.22 PWMFRSEL (CCh): PWM Frequency Selection
CCH PWMFRSEL (PWM Frequency Selection) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX PWMFRSEL 0 ↑ 1 - 1 1 0 0 1 1 0 0 (CCh) 1st Parameter 1 ↑ 1 - 0 0 CS2 CS1 CS0 CLK2 CLK1 CLK0 CS[2:0]/CLK[2:0]: CS[2:0] CLK[2:0] 00h 01h 02h 03h 04h 05h Unit:kHz Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 02h S/W Reset 02h H/W Reset 02h
Version 1.0 Page 293 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.23 PWCTRL1 (D0h): Power Control 1
D0H PWCTRL (Power Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX PWCTRL 0 ↑ 1 - 1 1 0 1 0 0 0 0 (D0h) 1st Parameter 1 ↑ 1 - 1 0 1 0 0 1 0 0 2nd Parameter 1 ↑ 1 - AVDD1 AVDD0 AVCL1 AVCL0 0 0 VDS1 VDS0 AVDD[1:0]: AVDD[1:0] AVDD (V) 00h 6.4 01h 6.6 02h 6.8 03h Reserved AVCL[1:0]: AVCL[1:0] AVCL (V) 00h -4.4 01h -4.6 02h -4.8 03h -5.0 VDS[1:0]: VDS[1:0] VDDS (V) 00h 2.19 01h 2.3 02h 2.4 03h 2.51 VDDS: Power of source OP Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes
Version 1.0 Page 294 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Default Status Default Value Power On Sequence A4h/A1h S/W Reset A4h/A1h H/W Reset A4h/A1h
Version 1.0 Page 295 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.24 VAPVANEN (D2h): Enable VAP/VAN signal output
D2H VAPVANEN (Enable VAP/VAN signal output) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX VAPVANEN 0 ↑ 1 - 1 1 0 1 0 0 1 0 (D2h) Parameter 1 ↑ 1 - 0 1 0 0 1 1 0 0 Description Enable VAP/VAN signal output Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 00h S/W Reset 00h H/W Reset 00h
Version 1.0 Page 296 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.25 CMD2EN (DFh): Command 2 Enable
DFH CMD2EN (Command 2 Enable) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX CMD2EN 0 ↑ 1 - 1 1 0 1 1 1 1 1 (DFh) 1st Parameter 1 ↑ 1 - 0 1 0 1 1 0 1 0 (5Ah) 2nd Parameter 1 ↑ 1 - 0 1 1 0 1 0 0 1 (69h) 3rd Parameter 1 ↑ 1 - 0 0 0 0 0 0 1 0 (02h) 4th Parameter 1 ↑ 1 - 0 0 0 0 0 0 0 EN EN: “0”: Commands in Command table 2 cannot be executed when EXTC level is “Low”. “1”: Commands in command table 2 can be executed when EXTC level is “Low”. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 5Ah/69h/02h/00h S/W Reset 5Ah/69h/02h/00h H/W Reset 5Ah/69h/02h/00h
Version 1.0 Page 297 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.26 PVGAMCTRL (E0h): Positive Voltage Gamma Control
E0H PVGAMCTRL (Positive Voltage Gamma Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX PVGAMCTRL 0 ↑ 1 - 1 1 1 0 0 0 0 0 (E0h) 1st Parameter 1 ↑ 1 - V63P3 V63P2 V63P1 V63P0 V0P3 V0P2 V0P1 V0P0 2nd Parameter 1 ↑ 1 - 0 0 V1P5 V1P4 V1P3 V1P2 V1P1 V1P0 3rd Parameter 1 ↑ 1 - 0 0 V2P5 V2P4 V2P3 V2P2 V2P1 V2P0 4th Parameter 1 ↑ 1 - 0 0 0 V4P4 V4P3 V4P2 V4P1 V4P0 5th Parameter 1 ↑ 1 - 0 0 0 V6P4 V6P3 V6P2 V6P1 V6P0 6th Parameter 1 ↑ 1 - 0 0 J0P1 J0P0 V13P3 V13P2 V13P1 V13P0 7th Parameter 1 ↑ 1 - 0 V20P6 V20P5 V20P4 V20P3 V20P2 V20P1 V20P0 8th Parameter 1 ↑ 1 - 0 V36P2 V36P1 V36P0 0 V27P2 V27P1 V27P0 9th Parameter 1 ↑ 1 - 0 V43P6 V43P5 V43P4 V43P3 V43P2 V43P1 V43P0 10 th Parameter 1 ↑ 1 - 0 0 J1P1 J1P0 V50P3 V50P2 V50P1 V50P0 11 th Parameter 1 ↑ 1 - 0 0 0 V57P4 V57P3 V57P2 V57P1 V57P0 12 th Parameter 1 ↑ 1 - 0 0 0 V59P4 V59P3 V59P2 V59P1 V59P0 13 th Parameter 1 ↑ 1 - 0 0 V61P5 V61P4 V61P3 V61P2 V61P1 V61P0 14 th Parameter 1 ↑ 1 - 0 0 V62P5 V62P4 V62P3 V62P2 V62P1 V62P0 Please refer to 8.19. Default value: Value(hex) VP0[3:0] 0 VP1[5:0] 2C VP2[5:0] 2E VP4[4:0] 15 VP6[4:0] 10 VP13[3:0] 9 VP20[6:0] 48 VP27[2:0] 3 VP36[2:0] 3 VP43[6:0] 53 VP50[3:0] B VP57[4:0] 19 VP59[4:0] 18 VP61[5:0] 20 VP62[5:0] 25
Version 1.0 Page 298 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. VP63[3:0] 7 JP0[1:0] 0 JP1[1:0] 0 Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Refer to description S/W Reset Refer to description H/W Reset Refer to description
Version 1.0 Page 299 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.27 NVGAMCTRL (E1h): Negative Voltage Gamma Control
E1H NVGAMCTRL (Negative Voltage Gamma Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX NVGAMCTRL 0 ↑ 1 - 1 1 1 0 0 0 0 1 (E1h) 1st Parameter 1 ↑ 1 - V63N3 V63N2 V63N1 V63N0 V0N3 V0N2 V0N1 V0N0 2nd Parameter 1 ↑ 1 - 0 0 V1N5 V1N4 V1N3 V1N2 V1N1 V1N0 3rd Parameter 1 ↑ 1 - 0 0 V2N5 V2N4 V2N3 V2N2 V2N1 V2N0 4th Parameter 1 ↑ 1 - 0 0 0 V4N4 V4N3 V4N2 V4N1 V4N0 5th Parameter 1 ↑ 1 - 0 0 0 V6N4 V6N3 V6N2 V6N1 V6N0 6th Parameter 1 ↑ 1 - 0 0 J0N1 J0N0 V13N3 V13N2 V13N1 V13N0 7th Parameter 1 ↑ 1 - 0 V20N6 V20N5 V20N4 V20N3 V20N2 V20N1 V20N0 8th Parameter 1 ↑ 1 - 0 V36N2 V36N1 V36N0 0 V27N2 V27N1 V27N0 9th Parameter 1 ↑ 1 - 0 V43N6 V43N5 V43N4 V43N3 V43N2 V43N1 V43N0 10 th Parameter 1 ↑ 1 - 0 0 J1N1 J1N0 V50N3 V50N2 V50N1 V50N0 11 th Parameter 1 ↑ 1 - 0 0 0 V57N4 V57N3 V57N2 V57N1 V57N0 12 th Parameter 1 ↑ 1 - 0 0 0 V59N4 V59N3 V59N2 V59N1 V59N0 13 th Parameter 1 ↑ 1 - 0 0 V61N5 V61N4 V61N3 V61N2 V61N1 V61N0 14 th Parameter 1 ↑ 1 - 0 0 V62N5 V62N4 V62N3 V62N2 V62N1 V62N0 Please refer to 8.19. Default value: Value(hex) VN0[3:0] 0 VN1[5:0] 2C VN2[5:0] 2E VN4[4:0] 15 VN6[4:0] 10 VN13[3:0] 9 VN20[6:0] 48 VN27[2:0] 3 VN36[2:0] 3 VN43[6:0] 53 VN50[3:0] B VN57[4:0] 19 VN59[4:0] 18 VN61[5:0] 20 VN62[5:0] 25
Version 1.0 Page 300 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. VN63[3:0] 7 JN0[1:0] 0 JN1[1:0] 0 Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Refer to description S/W Reset Refer to description H/W Reset Refer to description
Version 1.0 Page 301 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.28 DGMLUTR (E2h): Digital Gamma Look-up Table for Red
E2H DGMLUTR (Digital Gamma Look-up Table for Red) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX DGMLUTR 0 ↑ 1 - 1 1 1 0 0 0 1 0 (E2h) 1st Parameter 1 ↑ 1 - DGM_LUT_R00[7:0] 2nd Parameter 1 ↑ 1 - DGM_LUT_R01[7:0] … 1 ↑ 1 - 31 th Parameter 1 ↑ 1 - DGM_LUT_R30[7:0] 32 th Parameter 1 ↑ 1 - DGM_LUT_R31[7:0] … 1 ↑ 1 - 63 th Parameter 1 ↑ 1 - DGM_LUT_R62[7:0] 64 th Parameter 1 ↑ 1 - DGM_LUT_R63[7:0] Please refer to 8.20. Default value: Value(hex) DGM_LUT_R00[7:0] 00h DGM_LUT_R01[7:0] 04h DGM_LUT_R30[7:0] 78h DGM_LUT_R31[7:0] 7Ch DGM_LUT_R62[7:0] F8h DGM_LUT_R63[7:0] FCh Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Refer to description S/W Reset Refer to description
Version 1.0 Page 302 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. H/W Reset Refer to description
Version 1.0 Page 303 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.29 DGMLUTB (E3h): Digital Gamma Look-up Table for Blue
E3H DGMLUTB (Digital Gamma Look-up Table for Blue) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX DGMLUTB 0 ↑ 1 - 1 1 1 0 0 0 1 1 (E3h) 1st Parameter 1 ↑ 1 - DGM_LUT_B00[7:0] 2nd Parameter 1 ↑ 1 - DGM_LUT_B01[7:0] … 1 ↑ 1 - 31 th Parameter 1 ↑ 1 - DGM_LUT_B30[7:0] 32 th Parameter 1 ↑ 1 - DGM_LUT_B31[7:0] … 1 ↑ 1 - 63 th Parameter 1 ↑ 1 - DGM_LUT_B62[7:0] 64 th Parameter 1 ↑ 1 - DGM_LUT_B63[7:0] Please refer to 8.20. Default value: Value(hex) DGM_LUT_B00[7:0] 00h DGM_LUT_B01[7:0] 04h DGM_LUT_B30[7:0] 78h DGM_LUT_B31[7:0] 7Ch DGM_LUT_B62[7:0] F8h DGM_LUT_B63[7:0] FCh Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence Refer to description S/W Reset Refer to description
Version 1.0 Page 304 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. H/W Reset Refer to description
Version 1.0 Page 305 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.30 GATECTRL (E4h): Gate Control
E4H GATECTRL (Gate Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX GATECTRL 0 ↑ 1 - 1 1 1 0 0 1 0 0 (E4h) 1st Parameter 1 ↑ 1 - 0 0 NL5 NL4 NL3 NL2 NL1 NL0 2nd Parameter 1 ↑ 1 - 0 0 SCN5 SCN4 SCN3 SCN2 SCN1 SCN0 3rd Parameter 1 ↑ 1 - 0 0 0 TMG 0 SM 0 GS NL[5:0]: Set the number of gate line. NL[5:0] The number of gate line 0x00 8 gate line 0x01 16 gate line 0x02 24 gate line 0x27 320 gate line SCN[5:0]: set the first scan line SCN[5:0] The first scan line 0x00 Gate 0 0x01 Gate 8 0x27 Gate 312 TMG: Gate mirror selection TMG=”0”, local mirror as the number of gate line setting is not 320. TMG=”1”, full mirror as the number of gate line setting is 320. SM: Gate interlace mode selection SM=”0”: Gate scan using interlace mode. SM=”1”: Gate scan using non-interlace mode. GS: Gate scan direction GS=”0”: Gate scan direction is 0 /barb2right319 GS=”1”: Gate scan direction is 319 /barb2right0 Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes
Version 1.0 Page 306 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Default Status Default Value Power On Sequence 27h/00h/10h S/W Reset 27h/00h/10h H/W Reset 27h/00h/10h
Version 1.0 Page 307 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.31 SPI2EN (E7h): SPI2 Enable
E7H SPI2EN (SPI2 Enable) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX SPI2EN 0 ↑ 1 - 1 1 1 0 0 1 1 1 (E7h) Parameter 1 ↑ 1 - 0 0 0 SPI2EN 0 0 0 SPIRD SPI2EN: 2 data lane enable control. “0”: disable 2 data lane mode. “1”: enable 2 data lane mode SPIRD: SPI read enable for command table 2 “0”: commands in command table 2 can not be read in serial interface “1”: commands in command table 2 can be read in serial interface. Note: It needs one dummy clock if commands in command table 2 need to be read in serial interface. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 00h S/W Reset 00h H/W Reset 00h
Version 1.0 Page 308 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.32 PWCTRL2 (E8h): Power Control 2
E8H PWCTRL2 (Power Control 2) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX PWCTRL2 0 ↑ 1 - 1 1 1 0 1 0 0 0 (E8h) Parameter 1 ↑ 1 - 1 0 SBCLK1 SBCLK0 0 0 STP14CK1 STP14CK0 SBCLK[1:0]: Source booster clock selection SBCLK[1:0] 00h SBCLK DIV 2 01h SBCLK DIV 3 02h SBCLK DIV 4 03h SBCLK DIV 6 STP14CK[1:0]: STP14(AVDD/AVCL) booster clock selection STP14CK[1:0] 00h BCLK DIV 2 01h BCLK DIV 3 02h BCLK DIV 4 03h BCLK DIV 6 Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 93h S/W Reset 93h H/W Reset 93h
Version 1.0 Page 309 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.33 EQCTRL (E9h): Equalize time control
E9H EQCTRL (Equalize time Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX EQCTRL 0 ↑ 1 - 1 1 1 0 1 0 0 1 (E9h) 1st Parameter 1 ↑ 1 - 0 0 0 SEQ4 SEQ3 SEQ2 SEQ1 SEQ0 2nd Parameter 1 ↑ 1 - 0 0 0 SPRET4 SPRET3 SPRET2 SPRET1 SPRET0 3rd Parameter 1 ↑ 1 - 0 0 0 0 GEQ3 GEQ2 GEQ1 GEQ0 SEQ[4:0]:Source Equalize Time Source equalize time: SEQ[4:0]*400ns, SEQ[4:0]=0x01~0x1f In 18bit RGB interface: Source equalize time: SEQ[4:0]*4*1period of dotclk, SEQ[4:0]=0x01~0x1f In 6bit RGB interface: Source equalize time: SEQ[4:0]*4*3*1period of dotclk, SEQ[4:0]=0x01~0x1f SPRET[4:0]: Source Pre-drive Time Source pre-drive time: SPRET[4:0]*400ns, SPRET[4:0]=0x01~0x1f In 18bit RGB interface: Source equalize time: SPRET[4:0]*4*1period of dotclk, SPRET[4:0]=0x01~0x1f In 6bit RGB interface: Source equalize time: SPRET[4:0]*4*3*1period of dotclk, SPRET[4:0]=0x01~0x1f GEQ[3:0]: Gate Equalize Time Gate equalize time: GEQ[3:0]*400ns, GEQ[3:0]=0x00~0x0f In 18bit RGB interface: Gate equalize time: GEQ[3:0]*4*1period of dotclk, GEQ[3:0]=0x00~0x0f In 6bit RGB interface: Gate equalize time: GEQ[3:0]*4*3*1period of dotclk, GEQ[3:0]=0x00~0x0f Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes
Version 1.0 Page 310 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix. Default Status Default Value Power On Sequence 11h/11h/08h S/W Reset 11h/11h/08h H/W Reset 11h/11h/08h
Version 1.0 Page 311 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.34 PROMCTRL (ECh): Program Mode Control
ECH PROMCTRL (Program Mode Control) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX PROMCTRL 0 ↑ 1 - 1 1 1 0 1 1 0 0 (ECh) Parameter 1 ↑ 1 - 0 0 0 0 0 0 0 1 Description When program mode enable, this command need be set. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 00h S/W Reset 00h H/W Reset 00h
Version 1.0 Page 312 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.35 PROMEN (FAh): Program Mode Enable
FAH PROMEN (Program Mode Enable) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX PROMEN 0 ↑ 1 - 1 1 1 1 1 0 1 0 (FAh) 1st Parameter 1 ↑ 1 - 0 1 0 1 1 0 1 0 (5Ah) 2nd Parameter 1 ↑ 1 - 0 1 1 0 1 0 0 1 (69h) 3rd Parameter 1 ↑ 1 - 1 1 1 0 1 1 1 0 (EEh) 4th Parameter 1 ↑ 1 - 0 0 0 0 0 PROMEN 0 0 PROMEN: “0”: Program mode disable “1”: Program mode enable Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 00h S/W Reset 00h H/W Reset 00h
Version 1.0 Page 313 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.36 NVMSET (FCh): NVM Setting
FCH NVMSET (NVM Setting) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX NVMSET 0 ↑ 1 - 1 1 1 1 1 1 0 0 (FCh) 1st Parameter 1 ↑ 1 - ADD7 ADD6 ADD5 ADD4 ADD3 ADD2 ADD1 ADD0 2nd Parameter 1 ↑ 1 - D7 D6 D5 D4 D3 D2 D1 D0 ADD[7:0]: NVM address setting D[7:0]: Data setting of NVM address Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 00h/00h S/W Reset 00h/00h H/W Reset 00h/00h
Version 1.0 Page 314 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
9.2.37 PROMACT (FEh): Program action
FEH PROMACT (Program action) Inst / Para D/CX WRX RDX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX PROMACT 0 ↑ 1 - 1 1 1 1 1 1 1 0 (FEh) 1st Parameter 1 ↑ 1 - 0 0 1 0 1 0 0 1 (29h) 2nd Parameter 1 ↑ 1 - 1 0 1 0 0 1 0 1 (A5h) Description When program mode enable, this command need be set. Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value Power On Sequence 00h/00h S/W Reset 00h/00h H/W Reset 00h/00h
Version 1.0 Page 315 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
10 APPLICATION
10.1 Configuration of Power Supply Circuit
<10ohm <10ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <100ohm <10ohm <10ohm <10ohm <10ohm VGH VGH VGH VGH VGH VGH VGH DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY AGND AGND AGND AGND AGND AGND AGND AGND DUMMYR1 DUMMYR2 DUMMY DUMMY DUMMY DUMMY DUMMY Y X DUMMY DUMMY DUMMY G 1 G 3 G 5 G 7 G 9 G 11 G 13 S 1 S 2 S 3 S 4 S 5 S 6 S353 S354 S355 S356 S357 S358 S359 S360 S361 S362 S363 S364 S365 S366 S367 S368 S712 S713 S714 S715 S716 S717 S718 S719 S720 G320 G318 G316 G314 G312 G310 G308 G306 G12 G10 DUMMY DUMMY DUMMY DUMMY DUMMY VCOM VCOM VCOM VCOM VCOM VCOM VCOM VCOM DUMMY VAG VAG VDDS VDDS VDDGX VDDGX DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY VGL VGL VGL VGL VGL VGL AVDD AVDD AVDD AVDD AVDD AVDD AVDD AVCL AVCL AVCL AVCL AVCL AVCL AVCL VAN VAN DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY VAP VAP V20 V20 V20 V20 V20 V20 V20 DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY DUMMY VDD VDD VDD VDD VDD VDD VDD VDD AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND AGND DGND DGND DGND DGND DGND DGND DGND DGND TEST3 DUMMY DUMMY EXTC IM3 IM2 IM1 IM0 RESX CSX DCX WRX RDX TEST2 VSYNC HSYNC ENABLE DOTCLK DUMMY SDA DB0 DB1 DB2 DB3 TEST1 DB4 DB5 DB6 DB7 DUMMY DB8 DB9 DB10 DB11 TEST0 DB12 DB13 DB14 DB15 DUMMY DB16 DB17 TEST0 TE SDO LED_PWM LED_EN VDDI_LED VDDI_LED TE2 TESTO1 TESTO2 TESTO3 TESTO4 TESTO5 TESTO6 VDDI VDDI VDDI VDDI VDDI VDDI VDDI VCC VCC VCC VCC VCC VCC VCC VCC VCC VCC VCC VCC DUMMY DUMMY G303 G305 G307 G309 G311 G313 G315 G317 G319 VCOM VDD EXTC IM3 IM2IM1 IM0RESX CSX DCX WRX RDX VSYNC HSYNC ENABLE DOTCLK SDA DB0 DB1DB2 DB3 DB4 DB5DB6 DB7 DB8DB9 DB10 DB11 DB12 DB13 DB14 DB15 DB16 DB17 TE SDO LED_PWM LED_EN VDDI_LED VDDI FPC <10ohm VCC VCC DUMMY VPP VPP VPP VPP DUMMY DUMMY VGH VPP <10ohm VCOM DUMMY DUMMY VCOM VCOM VCOM VCOM VCOM VCOM VCOM VCOM
Version 1.0 Page 316 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
10.2 Voltage Generation
The following is the ST7789V2 analog voltage pattern diagram: Figure 38 Power Booster Level
Version 1.0 Page 317 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
10.3 Relationship about source voltage
The relationship about source voltage is shown as below: VP0 VP62 VP63 VP1 VAP VBP VN63 VN1 VN0 VN62 VBN VAN VP0 VP62 VP63 VP1 VAP VBP VN63 VN1 VN0 VN62 VBN VAN VP0 VP62 VP63 VP1 VAP VBP VN63 VN1 VN0 VN62 VBN VAN Figure 39 Relationship about source voltage Note: if VDV=0V, VBP=VBN=VCOM+VCOM OFFSET.
Version 1.0 Page 318 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
10.4 Applied Voltage to the TFT panel
Figure 40 Voltage Output to TFT LCD Panel
Version 1.0 Page 319 of 319 2016/11 Sitronix Confidential The information contained herein is the exclusive property of Sitronix and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Sitronix.
11 REVISION HISTORY
V1.0 2016/11 First issue