Features

  • Compliance with IEC60335-1 GWIF GWIT and CTI V.850℃/ 775℃ >=250
  • ≥6000 .Impulse withstand voltage V product is available High contact capability A switching capability:1 2 . Low coil power consumption low price,. ,.Microminiature relay standard PCB terminal Compliance EU RoHS and the requirement of white home appliances. SANYOU RELAYS Relays for advanced technology Miniature Power Relay version:V3.3 10,000,000 (at room temperature) 100,000 (at room temperature) Initial contact resistance (at 6VDC 1A) Operate time (at nominal volt.) Release time (at nominal volt.) Initial insulation resistance Initial dielectric strength Vibration resistance Shock resistance Endurance (operations) Ambient temperature Unit weight 10~55 1.5Hz at double amplitude of mm 10~55 1.5Hz at double amplitude od mm 10G Min. 100G Min. silver alloy 100 Ω . (1 6 )m Max A VDC 8msec. Max. (no diode) 5msec. Max. (no diode) 100 Ω . ( 500 )M Min DC V Between open contacts AC V Hz min: 750 ,50/60 1 . Between coil and contact: standard product AC 2,500V,50/60Hz 1min Czproduct with suffix"-6" : A 3000V,50/60H 1min Function Destructive Destructive Function -40℃~+85℃( )no condensation Approx.8.5g Impulse withstand voltage Between coil and contact standard product:≥ 4800V 1.2/50us ≥product with suffix"-6" 6000V 1.2/50us Contact material Please contact us if your working condition is 10 5℃ Model Nominal switching capacity (res. load) Max. switching current Max. switching voltage Max. switching power SRDI -DM 10A 250VAC 15A 277VAC 2,770VA SRDI -D NO10A 250VAC 12A 277VAC 2,770VA SRDI-DB 7A 250VAC 12A 277VAC 1,939VA NO/NC7A 250VAC
  • 60079-15Satisfy IEC product is available .

(2 0 ℃ )atCoil Data SRDI CQC02001002126 Safety Approval Ratings (Note:More detail of approval ratings,please refer to the safety certification) Approval File No. Approved ratings 7A 250VAC 5A 240VAC 10A 250VAC (Form A & Form C NO) E19059840034479 Contact code 2 o rNil: 10 250 ( , )AV A C Form C NO 7 250 ( , )A VAC Form CN O 6A 250VAC Form C NC(, ) Contact code or blank2: 10A 250VAC(Form A) 7 250 ( )A VAC Form A Contactcode 3 : 10 250 ( , )A VAC Form C NO 7 250 ( , )A VAC Form C NO 6 250 ( , )A VAC Form C NC Contact code 3: 10 250 ( )A VAC Form A 7 250 ( )A VAC Form A CQC VDE UL/CUL Nominal operating current 10% ( )mA Coil resistance 10% ( Ω) Max. allowable voltage Pick-up voltage (Max.) Drop-out voltage (Min.) Nominal operating power Nominal voltage (VDC) 120.00 71.42 60.00 40.00 30.00 24.00 20.00 15.00 7.50 6.00 100 225 400 625 900 1,600 6,400 10,000 1 3 0%o f nominal voltage 7 5%o f nominal voltage 5%o f nominal voltage 0.36W contact code Form C or Nil Form A or Form B2( ) ( ): contact code Form A or Form B or Nil Form C2( ) ( ): contact code or13 : contactcode 4: contactcode 5: 10 250 /28 ,A VAC VDC Generaluse NOResistive& , 7 250 ,A VAC Generaluse NO&NCResistive& , 7 250 ,A VAC Generaluse NO&NCResistive& , 10 250 ,A VAC Generaluse NOResistive& , 10 250 ,A VAC Generaluse NOResistive& , 10 250 /28 ,A VAC VDC Generaluse NOResistive& , ,,TV-3 120VAC NO ,,TV-3 120VAC NO 12 125 , , &A VAC Resistive NO NC 15 125 , ,A VAC Resistive NO 10 250 , ,A VAC Resistive NO 7 250 , , &A VAC General use NO NC 3 125 ,A VAC General Use,NO&NC 10 /6 28 , , /A A VDC General use NO NC ,,10A/6A 250VAC General use NO/NC ,,10A/6A 125VAC General use NO/NC ,,TV-5 120VAC NO ,,TV-3 120VAC NO 1/3HP 250VAC,NO&NC :,Pilot Duty 240VA 240VAC FLA 5A, LRA 10A, 120/ 240VAC, NO 1/3HP 250VAC,NO 1/3HP 250VAC,NO FLA 5A, LRA 10A, 120/ 240VAC, NO FLA 5A, LRA 10A, 120/ 240VAC, NO 12A/ , Generaluse NO15A 125VAC Resistive& , 12A/ , Generaluse NO15A 125VAC Resistive& , contactcode Form A or Form C)6:( 10A 277VAC,Resistive&General use ,NO 10A 277VAC,Resistive&General use ,NC (2) Only some typical ratings are listed above. Each rating’s test condition is different, so the electrical endurance will be different. (3) For sealed type testing, please open the ventilation hole of case before test. If more details are required, please contact us. (1) The above-mentioned unspecified temperature ratings, means that the ambient temperature is room temperature.

SRDI - S - 1 12 D M 1 -F- X X TypeDesignation SRDI: Number of Poles Pole:1-1 Special Parameter Nil Standard type:- Contact Material: Moveable contact for FormC Moveable contact for FormA Moveable contact for FormB Nil AgSnO Nil AgSnO Nil AgSnO- φ2.8 - φ3.0 - φ3.022 2 1- φ2.8 1- φ3.0 1- φ3.0AgCdO AgCdO AgCdO 2- φ3.0AgSnO2 6- φ3.0AgNi 3- φ3.0AgCdO 4-3 φ3.0compounds 5- φ3.0Cu plated with La Coil Power D W: -0.36 Coil Voltage VDC( ):03, 05, 06, 09, 12, 15, 18, 24, 48, 60 6- φ3.0AgNi Notes Dust covers with the marking of VDE are just for intend products with the suffixs of D:(1) " " " ", " 3"," 6", DD and" 2",D" " DM " 6". DM (2) φ3.0All stationary contacts specified as: mm. 6-6000V impulse withstandard voltage

Ordering Information

Outline Dimensions Wiring Diagram P C Board Layout unit mm,, . . ( : ) Insulation System Nil Standard B Class B F Class F:- , - , - Contact Form Nil Form C B Form B M Form A:- , - ,- Protective Construction S Flux proofed:- , SH-Sealed type washable Unless otherwise specified: If dimension mm tolerance mm<1 , : 0.2 ; If dimension mm tolerance mm1~5 , : 0.3 ; If dimension mm tolerance mm>5 , : 0.4 . Note Extended terminal dimension is dimension: .before soldering

Temp. Rise (K) Typical Applications Characteristic Curves Home appliances such as air conditioner, heater, etc. Automat Office equipment such as computer, fax machine, etc. Automatic eletric controlled window, automotive antenna, door lock, etc. Contact Current(A) Operations Ops ( 10000 Endurance Curve Contact Current(A) Contact Voltage(V) Max. Switching Power Percentage of Nominal Coil Voltage Coil Temp. Rise 100 10 100 1000 AC(1a) AC(1c) DC 100 28 ,250 /UNI963b/UNI6027VDC VAC 0 5 10 15 P.C.B. Layout (bottom view) Wiring Diagram (bottom view) Sanyou Corporation Limited, All rights of Sanyou to reserved. Disclaimer: This datasheet is the customers' reference. All the specification are subject to change without notice. We could not evaluate all the performance and all the parameters for every possible application.Thus the user should in a right position to choose the suitable product for their own application.For sealed relays after installation and cleaning, However it is the user's responsibility to determine which product should be used only. please open the vent hole on the case before use.If there is any query,please contact Sanyou for the technica service.