1000W Pure Sine Wave Inverter SR1000T series Voltage Range 18 ~ 34VDC 18 ~ 34VDC No Load Current 1.4A 0.75A 1.3A 0.7A 36 ~ 68VDC36 ~ 68VDC 36 ~ 60VDC (only UL) 36 ~ 68VDC MODEL SR1000T-124 SR1000T-148 SR1000T-224 SR1000T-248 Input Voltage 24VDC 48VDC 24VDC 48VDC Continuous Output Power Maximum Output Power (3min) Surge Power Frequency Output Voltage Efficiency (Full Load) 1000W 1100W 2000W 47 ~ 63Hz 0.5% (User-selectable)± 97 ~ 123VAC (User-selectable) 194 ~ 246VAC (User-selectable) 87% 88% 90% 91% Waveform Pure Sine Wave (THD < 2%) Output LCD Panel 2-line LCD Panel Input voltage level, output load level and faulty statusSignal & Control LED Indicator Dry Contact Terminal By relay Remote Control Port RJ-11 Input Protection Over / Under Voltage, Reverse Polarity (Fuse) Short-Circuit, Overload, Over Temperature Protection AC Output Protection AC Input Protection 12Amp Circuit Breaker 6Amp Circuit Breaker REV. A0 12/09/22 Bypass Relay Relay Specification Bypass Relay Selectable Switching Time 15Amp / 120VAC, 10Amp / 250VAC On Line / Off Line (Haphazard, Normal, Exacting) selectable From AC bypass mode (off-line mode): ≤ 20ms From DC to AC inverter mode (on-line mode): ≤ 8ms (Exacting Mode) Environment Working Temp. (Full Load) Storage 0°C ~ 50°C -30 ~ 70°C°C Certified EN 55022 Class B; EN 61000-3-2, -3-3; EN 55024; IEC 61000-4-2, 3, 4, 5, 6, 8, 11 Safety & EMC Safety Standards EMC Standards Certified FCC Class B Certified UL 62368-1 Certified EN 62368-1 Failure Indication Buzzer alarm and dry contact Cooling Thermal & Load control Fan Packing 7.46kg; 2pcs/ 15.9kg/ 1.74CUFT Dimension (WxHxD) 483x44x345 mm / 19.02x1.73x13.58 inchOthers Application Focus on Telecommunication (Base-station), Networking (Data Center) & Battery Backup Systems. Pure Sine Wave output (THD )< 2% Standard Rackmount19” 1U User-Friendly LCM Module Dry contact for system alarm RS- communication port232 Selectable On-line / Off-line modes Built-in AC transfer switch and AC breaker Hard-wire and dual AC outlet output connection Fan failure alarm with buzzer Input Protection: Reverse Polarity (Fuse) / Under Voltage / Over Voltage Output Protection: Short Circuit / Over Temperature Features: DATE ECOREV APPROVED REV. A4 20/10/20 36 ~ 60VDC (only UL) 2013/06/27 規格書整理Pony/Fendi 2014/10/28 Freq. 0.05%修正為0.5%,單位與重量修改Pony/薏 涵 2015/12/15 安規與尺寸修改Pony/薏 涵 安規資訊Carlos2020/10/20