SD3500 COTEK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

3500W Pure Sine Wave SD3500 series 3500VA ( de-rating after 35°C, refer to de-rating curve for 12V) (de-rating after 40°C, refer to de-rating curve for 24V and 48V SD3500-212 SD3500-224 SD3500-248SD3500-112 SD3500-124 SD3500-148 91%91%90%91%90% 40.0~64.0VDC 48VDC @48VDC 20.0~32.0VDC 24VDC @24VDC 12VDC 10.0~16.0VDC @12VDC 48VDC24VDC @48VDC@24VDC Pure Sine Wave 100 / 110 / 115 / 120VAC ±3% 200 / 220 / 230 / 240VAC 3%± 50 / 60Hz ±0.1% Parallel redundancy design for power expansion Automatic master mechanism to eliminate single point failure and optimize reliability Built-in ATS and AC circuit breaker RS-232 communication Input & output fully isolation Output voltage / power saving mode selectable by DIP switch or remote control (CR-10) Input Protection: Reverse Polarity (Fuse) / Under Voltage / Over Voltage Output Protection: Short Circuit / Overload / Over Temperature / Over Voltage Features: Optional STS module, transfer time less 4ms. Multiple industrial applications that create 1 3W / 3 4W power systems Ф Ф 20Ax620Ax12 20Ax620Ax1240Ax12 47 - 57 / 53 - 63 Hz 20A Optional STS module : Single < 4ms; N+1&1P3W&3P4W < 6ms Standard ATS : Inverter to utility AC:8~10ms.; Utility AC to inverter: 16~50ms. Load & Thermal control fan 283x128x496 mm / 11.14x5.04x19.53 inch RS-232 (RJ-11 type connector), Ethernet (optional) Max. 90%, non-condersing -40 ~ +70°C Reverse Polarity (Fuse) / Under Voltage / Over Voltage Protection / AC over current (Breaker) Short Circuit / Overload / Over Temperature / Over Voltage 50.0VDC 62.0VDC 64.0VDC 25.0VDC 31.0VDC 32.0VDC 30.0VDC 12.5VDC 15.5VDC 16.0VDC 15.0VDC 50.0VDC 62.0VDC 64.0VDC 60.0VDC 25.0VDC 31.0VDC 32.0VDC 30.0VDC 42.0VDC10.5VDC42.0VDC21.0VDC -20 ~ +60°C; refer to SD3500 power de-rating curve Input voltage level, faulty status CR-6, CR-8 and CR-10 Certified EN62368-1 UL 458 (UL only for hardwire)Certified 21.0VDC 60.0VDC Rating Power Efficiency (Max.) DC Voltage Voltage Range No load Power Consumption Waveform Output Frequency Output Voltage (@rated VDC) On Mode @ No Load Mode On Mode @ Save Mode AC Range Frequency Selectable Synchronous Frequency Circuit Breaker Transfer Switch * Cooling Parking Dimension (WxHxD) Communication Port Relative Humidity Working Temp. Storage Temp. BAT.High Alarm ±3% BAT.High Restart ±3% BAT.Low Restart ±3% BAT.High Shut-down ±3% Input Protection Output Protection BAT.Low Shut-down ±3% BAT.Low Alarm ±3% LED Indicator Remote control Safety Standards Output DC Input Fuse Others Environment Protection Control & Signal Safety & EMC AC Input MODEL 4500 ~ 6000VA >6000VA 90% 12VDC @12VDC 40Ax12 50 / 60 Hz 35A 12.5VDC 15.5VDC 16.0VDC 15.0VDC 10.0VDC 10.5VDC 10 kg; 2pcs / 21kg / 3.19cuft < 3% @ under condition : greater than 1.15 times of the rated VDC, 110V / linear load)Total Harmonic Distortion (THD) < 3% @ under condition : greater than 1.15 times of the rated VDC, 230V / linear load) Certified FCC Class BEMC Standards Note *UL-458 only support 112 and 124 model. EN55014-1, EN55014-2 Class B : output cable less than 2 meters. *Please refer to Transfer - Time Table. Certified CISPR 25; ISO 7637-2E-Mark – REV. A8 21/10/06 100 / 110 / 115 / 120VAC 25%, recover± ±12.5% 200 / 220 / 230 / 240VAC 25%± , recover±12.5% **Certified EN 55014-1, EN 61000-3-2, 3-3, EN61204-3; EN 55014-2, EN 62368-1 3500 ~ 4500VA Peak Power (Max. 3 sec.) Surge Power (Max. 0.2 sec.) Output Power (Max. 3 min.)

LED Status: Output Socket: De-rating Curve: 3500W Pure Sine Wave SD3500 series United Kingdom Universal UL458 13~16V 12V 11V 10V Orange LED LED Signal Solid Slow Blink Intermittent Blink Status Power OK Power Saving Bypass Green LED LED Signal Status Fast Blink Slow Blink OVP UVP Red LED LED Signal Status Fast Blink Slow Blink OVP- Shut-down UVP- Shut-down Intermittent Blink OTP Solid OLP Intermittent Blink Fan Failure Intermittent Blink Component Failure REV. A8 21/10/06

Mechanical Drawings: Unit : mm [inch] 3500W Pure Sine Wave SD3500 series 283 [11.14] 268.6 [10.57] 8.5 [0.33] 496 [19.53] 128 [5.04] Transfer Time : Mode\\Transfer Switch STS <4ms Frequency is synchronized : <4ms Frequency is not synchronized : Inverter to utility AC : <4ms.; Utility AC to inverter : 16 ~ 50ms. Inverter to utility AC : <4ms.; Utility AC to inverter : 16 ~ 50ms. ATS Inverter to utility AC : 8 ~ 10ms.; Utility AC to inverter : 16 ~ 25ms. Inverter to utility AC : 8 ~ 10ms.; Utility AC to inverter : 16 ~ 50ms. Inverter to utility AC : 8 ~ 10ms.; Utility AC to inverter : 16 ~ 25ms. Inverter to utility AC : 8 ~ 10ms.; Utility AC to inverter : 16 ~ 50ms. <4ms Haphazard Normal Exacting Online Transfer-Time Table REV. A8 21/10/06